1
|
Sato R, Akiyama Y, Mikami T, Yamaoka A, Kamada C, Sakashita K, Takahashi Y, Kimura Y, Komatsu K, Mikuni N. Deep learning from head CT scans to predict elevated intracranial pressure. J Neuroimaging 2024. [PMID: 39387348 DOI: 10.1111/jon.13241] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2024] [Revised: 09/05/2024] [Accepted: 09/24/2024] [Indexed: 10/15/2024] Open
Abstract
BACKGROUND AND PURPOSE Elevated intracranial pressure (ICP) resulting from severe head injury or stroke poses a risk of secondary brain injury that requires neurosurgical intervention. However, currently available noninvasive monitoring techniques for predicting ICP are not sufficiently advanced. We aimed to develop a minimally invasive ICP prediction model using simple CT images to prevent secondary brain injury caused by elevated ICP. METHODS We used the following three methods to determine the presence or absence of elevated ICP using midbrain-level CT images: (1) a deep learning model created using the Python (PY) programming language; (2) a model based on cistern narrowing and scaling of brainstem deformities and presence of hydrocephalus, analyzed using the statistical tool Prediction One (PO); and (3) identification of ICP by senior residents (SRs). We compared the accuracy of the validation and test data using fivefold cross-validation and visualized or quantified the areas of interest in the models. RESULTS The accuracy of the validation data for the PY, PO, and SR methods was 83.68% (83.42%-85.13%), 85.71% (73.81%-88.10%), and 66.67% (55.96%-72.62%), respectively. Significant differences in accuracy were observed between the PY and SR methods. Test data accuracy was 77.27% (70.45%-77.2%), 84.09% (75.00%-85.23%), and 61.36% (56.82%-68.18%), respectively. CONCLUSIONS Overall, the outcomes suggest that these newly developed models may be valuable tools for the rapid and accurate detection of elevated ICP in clinical practice. These models can easily be applied to other sites, as a single CT image at the midbrain level can provide a highly accurate diagnosis.
Collapse
Affiliation(s)
- Ryota Sato
- Department of Neurosurgery, Sapporo Medical University, Sapporo, Japan
| | - Yukinori Akiyama
- Department of Neurosurgery, Sapporo Medical University, Sapporo, Japan
| | - Takeshi Mikami
- Department of Neurosurgery, Sapporo Medical University, Sapporo, Japan
| | - Ayumu Yamaoka
- Department of Neurosurgery, Sapporo Medical University, Sapporo, Japan
| | - Chie Kamada
- Department of Neurosurgery, Sapporo Medical University, Sapporo, Japan
| | - Kyoya Sakashita
- Department of Neurosurgery, Sapporo Medical University, Sapporo, Japan
| | | | - Yusuke Kimura
- Department of Neurosurgery, Sapporo Medical University, Sapporo, Japan
| | - Katsuya Komatsu
- Department of Neurosurgery, Sapporo Medical University, Sapporo, Japan
| | - Nobuhiro Mikuni
- Department of Neurosurgery, Sapporo Medical University, Sapporo, Japan
| |
Collapse
|
2
|
Srichawla BS. Future of neurocritical care: Integrating neurophysics, multimodal monitoring, and machine learning. World J Crit Care Med 2024; 13:91397. [PMID: 38855276 PMCID: PMC11155497 DOI: 10.5492/wjccm.v13.i2.91397] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/27/2023] [Revised: 01/27/2024] [Accepted: 03/06/2024] [Indexed: 06/03/2024] Open
Abstract
Multimodal monitoring (MMM) in the intensive care unit (ICU) has become increasingly sophisticated with the integration of neurophysical principles. However, the challenge remains to select and interpret the most appropriate combination of neuromonitoring modalities to optimize patient outcomes. This manuscript reviewed current neuromonitoring tools, focusing on intracranial pressure, cerebral electrical activity, metabolism, and invasive and noninvasive autoregulation monitoring. In addition, the integration of advanced machine learning and data science tools within the ICU were discussed. Invasive monitoring includes analysis of intracranial pressure waveforms, jugular venous oximetry, monitoring of brain tissue oxygenation, thermal diffusion flowmetry, electrocorticography, depth electroencephalography, and cerebral microdialysis. Noninvasive measures include transcranial Doppler, tympanic membrane displacement, near-infrared spectroscopy, optic nerve sheath diameter, positron emission tomography, and systemic hemodynamic monitoring including heart rate variability analysis. The neurophysical basis and clinical relevance of each method within the ICU setting were examined. Machine learning algorithms have shown promise by helping to analyze and interpret data in real time from continuous MMM tools, helping clinicians make more accurate and timely decisions. These algorithms can integrate diverse data streams to generate predictive models for patient outcomes and optimize treatment strategies. MMM, grounded in neurophysics, offers a more nuanced understanding of cerebral physiology and disease in the ICU. Although each modality has its strengths and limitations, its integrated use, especially in combination with machine learning algorithms, can offer invaluable information for individualized patient care.
Collapse
Affiliation(s)
- Bahadar S Srichawla
- Department of Neurology, University of Massachusetts Chan Medical School, Worcester, MA 01655, United States
| |
Collapse
|
3
|
Uryga A, Kazimierska A, Popek M, Dragan B, Burzyńska M, Masalski M, Kasprowicz M. Applying video motion magnification to reveal spontaneous tympanic membrane displacement as an indirect measure of intracranial pressure in patients with brain pathologies. Acta Neurochir (Wien) 2023; 165:2227-2235. [PMID: 37369772 PMCID: PMC10409653 DOI: 10.1007/s00701-023-05681-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2023] [Accepted: 06/12/2023] [Indexed: 06/29/2023]
Abstract
BACKGROUND The observation of tympanic membrane displacement (TMD) opens up the possibility of indirect intracranial pressure (ICP) estimation. In this study, we applied a phase-based video motion magnification (VMM) algorithm to reveal spontaneous pulse TMD waveforms (spTMD) and compare them with invasively measured ICP in patients with intracranial pathologies. METHODS Nine adults (six traumatic brain injury and three aneurysmal subarachnoid haemorrhage; median age 44 (29-53) years admitted to the intensive care unit of Wroclaw Medical University between October 2021 and October 2022 with implanted ICP sensors were included in this retrospective study. Video recordings of the tympanic membrane were performed using a portable otoscope with a video camera and analysed by a custom-written VMM algorithm. ICP was monitored using intraparenchymal sensors and arterial blood pressure (ABP) was measured in the radial arterial lines. ICP, ABP, and spTMD videos were captured simultaneously. The pulse amplitudes of ICP (Amp_ICP), ABP (Amp_ABP) and spTMD (Amp_spTMD) were estimated using fast Fourier transform within the heart rate (HR)-related frequency range. RESULTS Amp_spTMD was significantly correlated with mean ICP (rS = 0.73; p = 0.025) and with Amp_ICP (rS = 0.88; p = 0.002). Age was not a significant moderator of this association. There were no significant relationships between Amp_spTMD and either mean ABP, HR, or Amp_ABP. CONCLUSIONS The study suggests that Amp_spTMD increases with the increase in mean ICP and Amp_ICP. Estimation of Amp_spTMD using the VMM algorithm has the potential to allow for non-invasive detection of the risk of elevated ICP; however, further investigation in a larger group of patients is required.
Collapse
Affiliation(s)
- Agnieszka Uryga
- Department of Biomedical Engineering, Wroclaw University of Science and Technology, Wybrzeże Wyspiańskiego 27, 50-370, Wroclaw, Poland.
| | - Agnieszka Kazimierska
- Department of Biomedical Engineering, Wroclaw University of Science and Technology, Wybrzeże Wyspiańskiego 27, 50-370, Wroclaw, Poland
| | - Mateusz Popek
- Department of Biomedical Engineering, Wroclaw University of Science and Technology, Wybrzeże Wyspiańskiego 27, 50-370, Wroclaw, Poland
| | - Barbara Dragan
- Department of Anaesthesiology and Intensive Therapy, Wroclaw Medical University, Borowska 213, 50-566, Wroclaw, Poland
| | - Małgorzata Burzyńska
- Department of Anaesthesiology and Intensive Therapy, Wroclaw Medical University, Borowska 213, 50-566, Wroclaw, Poland
| | - Marcin Masalski
- Department of Biomedical Engineering, Wroclaw University of Science and Technology, Wybrzeże Wyspiańskiego 27, 50-370, Wroclaw, Poland
- Department and Clinic of Otolaryngology, Head and Neck Surgery, Wroclaw Medical University, Borowska 213, 50-566, Wroclaw, Poland
| | - Magdalena Kasprowicz
- Department of Biomedical Engineering, Wroclaw University of Science and Technology, Wybrzeże Wyspiańskiego 27, 50-370, Wroclaw, Poland.
| |
Collapse
|
4
|
Mathiesen BK, Miyakoshi LM, Cederroth CR, Tserga E, Versteegh C, Bork PAR, Hauglund NL, Gomolka RS, Mori Y, Edvall NK, Rouse S, Møllgård K, Holt JR, Nedergaard M, Canlon B. Delivery of gene therapy through a cerebrospinal fluid conduit to rescue hearing in adult mice. Sci Transl Med 2023; 15:eabq3916. [PMID: 37379370 DOI: 10.1126/scitranslmed.abq3916] [Citation(s) in RCA: 12] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2022] [Accepted: 06/09/2023] [Indexed: 06/30/2023]
Abstract
Inner ear gene therapy has recently effectively restored hearing in neonatal mice, but it is complicated in adulthood by the structural inaccessibility of the cochlea, which is embedded within the temporal bone. Alternative delivery routes may advance auditory research and also prove useful when translated to humans with progressive genetic-mediated hearing loss. Cerebrospinal fluid flow via the glymphatic system is emerging as a new approach for brain-wide drug delivery in rodents as well as humans. The cerebrospinal fluid and the fluid of the inner ear are connected via a bony channel called the cochlear aqueduct, but previous studies have not explored the possibility of delivering gene therapy via the cerebrospinal fluid to restore hearing in adult deaf mice. Here, we showed that the cochlear aqueduct in mice exhibits lymphatic-like characteristics. In vivo time-lapse magnetic resonance imaging, computed tomography, and optical fluorescence microscopy showed that large-particle tracers injected into the cerebrospinal fluid reached the inner ear by dispersive transport via the cochlear aqueduct in adult mice. A single intracisternal injection of adeno-associated virus carrying solute carrier family 17, member 8 (Slc17A8), which encodes vesicular glutamate transporter-3 (VGLUT3), rescued hearing in adult deaf Slc17A8-/- mice by restoring VGLUT3 protein expression in inner hair cells, with minimal ectopic expression in the brain and none in the liver. Our findings demonstrate that cerebrospinal fluid transport comprises an accessible route for gene delivery to the adult inner ear and may represent an important step toward using gene therapy to restore hearing in humans.
Collapse
Affiliation(s)
- Barbara K Mathiesen
- Center for Translational Neuromedicine, Division of Glial Disease and Therapeutics, Faculty of Health and Medical Sciences, University of Copenhagen, 2200, Denmark
| | - Leo M Miyakoshi
- Center for Translational Neuromedicine, Division of Glial Disease and Therapeutics, Faculty of Health and Medical Sciences, University of Copenhagen, 2200, Denmark
| | - Christopher R Cederroth
- Department of Physiology and Pharmacology, Karolinska Institutet, Solnavägen 9, Biomedicum, 171 65 Stockholm, Sweden
- Translational Hearing Research, Tübingen Hearing Research Center, Department of Otolaryngology, Head and Neck Surgery, University of Tübingen, Tübingen, Germany
| | - Evangelia Tserga
- Department of Physiology and Pharmacology, Karolinska Institutet, Solnavägen 9, Biomedicum, 171 65 Stockholm, Sweden
| | - Corstiaen Versteegh
- Department of Physiology and Pharmacology, Karolinska Institutet, Solnavägen 9, Biomedicum, 171 65 Stockholm, Sweden
| | - Peter A R Bork
- Center for Translational Neuromedicine, Division of Glial Disease and Therapeutics, Faculty of Health and Medical Sciences, University of Copenhagen, 2200, Denmark
| | - Natalie L Hauglund
- Center for Translational Neuromedicine, Division of Glial Disease and Therapeutics, Faculty of Health and Medical Sciences, University of Copenhagen, 2200, Denmark
| | - Ryszard Stefan Gomolka
- Center for Translational Neuromedicine, Division of Glial Disease and Therapeutics, Faculty of Health and Medical Sciences, University of Copenhagen, 2200, Denmark
| | - Yuki Mori
- Center for Translational Neuromedicine, Division of Glial Disease and Therapeutics, Faculty of Health and Medical Sciences, University of Copenhagen, 2200, Denmark
| | - Niklas K Edvall
- Department of Physiology and Pharmacology, Karolinska Institutet, Solnavägen 9, Biomedicum, 171 65 Stockholm, Sweden
| | - Stephanie Rouse
- Department of Otolaryngology and Neurology, Boston Children's Hospital and Harvard Medical School, Boston, MA 02115, USA
| | - Kjeld Møllgård
- Department of Cellular and Molecular Medicine, Faculty of Health and Medical Sciences, University of Copenhagen; Copenhagen, 2200, Denmark
| | - Jeffrey R Holt
- Department of Otolaryngology and Neurology, Boston Children's Hospital and Harvard Medical School, Boston, MA 02115, USA
| | - Maiken Nedergaard
- Center for Translational Neuromedicine, Division of Glial Disease and Therapeutics, Faculty of Health and Medical Sciences, University of Copenhagen, 2200, Denmark
- Center for Translational Neuromedicine, Division of Glial Disease and Therapeutics, University of Rochester Medical Center; Rochester, NY 14642, USA
| | - Barbara Canlon
- Department of Physiology and Pharmacology, Karolinska Institutet, Solnavägen 9, Biomedicum, 171 65 Stockholm, Sweden
| |
Collapse
|
5
|
Manga S, Muthavarapu N, Redij R, Baraskar B, Kaur A, Gaddam S, Gopalakrishnan K, Shinde R, Rajagopal A, Samaddar P, Damani DN, Shivaram S, Dey S, Mitra D, Roy S, Kulkarni K, Arunachalam SP. Estimation of Physiologic Pressures: Invasive and Non-Invasive Techniques, AI Models, and Future Perspectives. SENSORS (BASEL, SWITZERLAND) 2023; 23:5744. [PMID: 37420919 DOI: 10.3390/s23125744] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/01/2023] [Revised: 05/25/2023] [Accepted: 06/12/2023] [Indexed: 07/09/2023]
Abstract
The measurement of physiologic pressure helps diagnose and prevent associated health complications. From typical conventional methods to more complicated modalities, such as the estimation of intracranial pressures, numerous invasive and noninvasive tools that provide us with insight into daily physiology and aid in understanding pathology are within our grasp. Currently, our standards for estimating vital pressures, including continuous BP measurements, pulmonary capillary wedge pressures, and hepatic portal gradients, involve the use of invasive modalities. As an emerging field in medical technology, artificial intelligence (AI) has been incorporated into analyzing and predicting patterns of physiologic pressures. AI has been used to construct models that have clinical applicability both in hospital settings and at-home settings for ease of use for patients. Studies applying AI to each of these compartmental pressures were searched and shortlisted for thorough assessment and review. There are several AI-based innovations in noninvasive blood pressure estimation based on imaging, auscultation, oscillometry and wearable technology employing biosignals. The purpose of this review is to provide an in-depth assessment of the involved physiologies, prevailing methodologies and emerging technologies incorporating AI in clinical practice for each type of compartmental pressure measurement. We also bring to the forefront AI-based noninvasive estimation techniques for physiologic pressure based on microwave systems that have promising potential for clinical practice.
Collapse
Affiliation(s)
- Sharanya Manga
- Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN 55905, USA
| | - Neha Muthavarapu
- Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN 55905, USA
| | - Renisha Redij
- GIH Artificial Intelligence Laboratory (GAIL), Division of Gastroenterology and Hepatology, Department of Medicine, Mayo Clinic, Rochester, MN 55905, USA
| | | | - Avneet Kaur
- Microwave Engineering and Imaging Laboratory (MEIL), Division of Gastroenterology and Hepatology, Department of Medicine, Mayo Clinic, Rochester, MN 55905, USA
| | - Sunil Gaddam
- Microwave Engineering and Imaging Laboratory (MEIL), Division of Gastroenterology and Hepatology, Department of Medicine, Mayo Clinic, Rochester, MN 55905, USA
| | - Keerthy Gopalakrishnan
- GIH Artificial Intelligence Laboratory (GAIL), Division of Gastroenterology and Hepatology, Department of Medicine, Mayo Clinic, Rochester, MN 55905, USA
- Microwave Engineering and Imaging Laboratory (MEIL), Division of Gastroenterology and Hepatology, Department of Medicine, Mayo Clinic, Rochester, MN 55905, USA
| | - Rutuja Shinde
- Department of Medicine, Mayo Clinic, Rochester, MN 55905, USA
| | | | - Poulami Samaddar
- Microwave Engineering and Imaging Laboratory (MEIL), Division of Gastroenterology and Hepatology, Department of Medicine, Mayo Clinic, Rochester, MN 55905, USA
| | - Devanshi N Damani
- Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN 55905, USA
- Department of Internal Medicine, Texas Tech University Health Science Center, El Paso, TX 79995, USA
| | - Suganti Shivaram
- Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, MN 55905, USA
| | - Shuvashis Dey
- Microwave Engineering and Imaging Laboratory (MEIL), Division of Gastroenterology and Hepatology, Department of Medicine, Mayo Clinic, Rochester, MN 55905, USA
- Department of Electrical and Computer Engineering, North Dakota State University, Fargo, ND 58105, USA
| | - Dipankar Mitra
- Microwave Engineering and Imaging Laboratory (MEIL), Division of Gastroenterology and Hepatology, Department of Medicine, Mayo Clinic, Rochester, MN 55905, USA
- Department of Computer Science, University of Wisconsin-La Crosse, La Crosse, WI 54601, USA
| | - Sayan Roy
- Microwave Engineering and Imaging Laboratory (MEIL), Division of Gastroenterology and Hepatology, Department of Medicine, Mayo Clinic, Rochester, MN 55905, USA
- Department of Electrical Engineering and Computer Science, South Dakota Mines, Rapid City, SD 57701, USA
| | - Kanchan Kulkarni
- Centre de Recherche Cardio-Thoracique de Bordeaux, University of Bordeaux, INSERM, U1045, 33000 Bordeaux, France
- IHU Liryc, Heart Rhythm Disease Institute, Fondation Bordeaux Université, Bordeaux, 33600 Pessac, France
| | - Shivaram P Arunachalam
- GIH Artificial Intelligence Laboratory (GAIL), Division of Gastroenterology and Hepatology, Department of Medicine, Mayo Clinic, Rochester, MN 55905, USA
- Department of Radiology, Mayo Clinic, Rochester, MN 55905, USA
- Microwave Engineering and Imaging Laboratory (MEIL), Division of Gastroenterology and Hepatology, Department of Medicine, Mayo Clinic, Rochester, MN 55905, USA
- Department of Medicine, Mayo Clinic, Rochester, MN 55905, USA
| |
Collapse
|
6
|
Schmidt B, Czosnyka M, Cardim D, Czosnyka Z, Rosengarten B. Is Lumbar Puncture Needed? - Noninvasive Assessment of ICP Facilitates Decision Making in Patients with Suspected Idiopathic Intracranial Hypertension. ULTRASCHALL IN DER MEDIZIN (STUTTGART, GERMANY : 1980) 2023; 44:e91-e98. [PMID: 34496407 PMCID: PMC10063336 DOI: 10.1055/a-1586-6487] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/05/2021] [Accepted: 06/25/2021] [Indexed: 06/13/2023]
Abstract
PURPOSE Idiopathic intracranial hypertension (IIH) usually occurs in obese women of childbearing age. Typical symptoms are headache and sight impairment. Lumbar puncture (LP) is routinely used for both diagnosis and therapy (via cerebrospinal fluid drainage) of IIH. In this study, noninvasively assessed intracranial pressure (nICP) was compared to LP pressure (LPP) in order to clarify its feasibility for the diagnosis of IIH. MATERIALS AND METHODS nICP was calculated using continuous signals of arterial blood pressure and cerebral blood flow velocity in the middle cerebral artery, a method which has been introduced recently. In 26 patients (f = 24, m = 2; age: 33 ± 11 years), nICP was assessed one hour prior to LPP. If LPP was > 20 cmH2O, lumbar drainage was performed, LPP was measured again, and also nICP was reassessed. RESULTS In total, LPP and nICP correlated with R = 0.85 (p < 0.001; N = 38). The mean difference of nICP-LPP was 0.45 ± 4.93 cmH2O. The capability of nICP to diagnose increased LPP (LPP > 20 cmH2O) was assessed by ROC analysis. The optimal cutoff for nICP was close to 20 cmH2O with both a sensitivity and specificity of 0.92. Presuming 20 cmH2O as a critical threshold for the indication of lumbar drainage, the clinical implications would coincide in both methods in 35 of 38 cases. CONCLUSION The TCD-based nICP assessment seems to be suitable for a pre-diagnosis of increased LPP and might eliminated the need for painful lumbar puncture if low nICP is detected.
Collapse
Affiliation(s)
| | - Marek Czosnyka
- Brain Physics Laboratory, Clinical Neurosciences, University of Cambridge, United Kingdom of Great Britain and Northern Ireland
| | - Danilo Cardim
- Neurology, The University of Texas Southwestern Medical Center, Dallas, United States
| | - Zofia Czosnyka
- Brain Physics Laboratory, Clinical Neurosciences, University of Cambridge, United Kingdom of Great Britain and Northern Ireland
| | | |
Collapse
|
7
|
Dattilo M. Noninvasive methods to monitor intracranial pressure. Curr Opin Neurol 2023; 36:1-9. [PMID: 36630209 DOI: 10.1097/wco.0000000000001126] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
PURPOSE OF REVIEW Intracranial pressure (ICP) is determined by the production of and outflow facility of cerebrospinal fluid. Since alterations in ICP are implicated in several vision-threatening and life-threatening diseases, measurement of ICP is necessary and common. All current clinical methods to measure ICP are invasive and carry the risk for significant side effects. Therefore, the development of accurate, reliable, objective, and portal noninvasive devices to measure ICP has the potential to change the practice of medicine. This review discusses recent advances and barriers to the clinical implementation of noninvasive devices to determine ICP. RECENT FINDINGS Many noninvasive methods to determine ICP have been developed. Although most have significant limitations limiting their clinical utility, several noninvasive methods have shown strong correlations with invasively obtained ICP and have excellent potential to be developed further to accurately quantify ICP and ICP changes. SUMMARY Although invasive methods remain the mainstay for ICP determination and monitoring, several noninvasive biomarkers have shown promise to quantitatively assess and monitor ICP. With further refinement and advancement of these techniques, it is highly possible that noninvasive methods will become more commonplace and may complement or even supplant invasively obtained methods to determine ICP in certain situations.
Collapse
Affiliation(s)
- Michael Dattilo
- Emory Eye Center, Neuro-Ophthalmology Division, Emory University School of Medicine, Atlanta, Georgia, USA
| |
Collapse
|
8
|
Fan TH, Rosenthal ES. Physiological Monitoring in Patients with Acute Brain Injury: A Multimodal Approach. Crit Care Clin 2023; 39:221-233. [PMID: 36333033 DOI: 10.1016/j.ccc.2022.06.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Neurocritical care management of acute brain injury (ABI) is focused on identification, prevention, and management of secondary brain injury (SBI). Physiologic monitoring of the brain and other organ systems has a role to predict patient recovery or deterioration, guide individualized therapeutic interventions, and measure response to treatment, with the goal of improving patient outcomes. In this review, we detail how specific physiologic markers of brain injury and neuromonitoring tools are integrated and used in ABI patients to develop therapeutic approaches to prevent SBI.
Collapse
Affiliation(s)
- Tracey H Fan
- Department of Neurology, Division of Neurocritical Care, Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02493, USA; Department of Neurology, Division of Neurocritical Care, Brigham and Women's Hospital, 55 Fruit Street, Boston, MA 02493, USA
| | - Eric S Rosenthal
- Department of Neurology, Division of Neurocritical Care, Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02493, USA; Department of Neurology, Division of Clinical Neurophysiology, Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02493, USA.
| |
Collapse
|
9
|
Morgan WH, Vukmirovic A, Abdul-Rahman A, Khoo YJ, Kermode AG, Lind CR, Dunuwille J, Yu DY. Zero retinal vein pulsation amplitude extrapolated model in non-invasive intracranial pressure estimation. Sci Rep 2022; 12:5190. [PMID: 35338201 PMCID: PMC8956690 DOI: 10.1038/s41598-022-09151-7] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2021] [Accepted: 03/11/2022] [Indexed: 11/09/2022] Open
Abstract
Intracranial pressure (ICP) includes the brain, optic nerve, and spinal cord pressures; it influences blood flow to those structures. Pathological elevation in ICP results in structural damage through various mechanisms, which adversely affects outcomes in traumatic brain injury and stroke. Currently, invasive procedures which tap directly into the cerebrospinal fluid are required to measure this pressure. Recent fluidic engineering modelling analogous to the ocular vascular flow suggests that retinal venous pulse amplitudes are predictably influenced by downstream pressures, suggesting that ICP could be estimated by analysing this pulse signal. We used this modelling theory and our photoplethysmographic (PPG) retinal venous pulse amplitude measurement system to measure amplitudes in 30 subjects undergoing invasive ICP measurements by lumbar puncture (LP) or external ventricular drain (EVD). We estimated ICP from these amplitudes using this modelling and found it to be accurate with a mean absolute error of 3.0 mmHg and a slope of 1.00 (r = 0.91). Ninety-four percent of differences between the PPG and invasive method were between − 5.5 and + 4.0 mmHg, which compares favourably to comparisons between LP and EVD. This type of modelling may be useful for understanding retinal vessel pulsatile fluid dynamics and may provide a method for non-invasive ICP measurement.
Collapse
Affiliation(s)
- W H Morgan
- Lions Eye Institute, Centre for Ophthalmology and Visual Science, University of Western Australia, Perth, Australia.
| | - A Vukmirovic
- Lions Eye Institute, Centre for Ophthalmology and Visual Science, University of Western Australia, Perth, Australia
| | - A Abdul-Rahman
- Lions Eye Institute, Centre for Ophthalmology and Visual Science, University of Western Australia, Perth, Australia.,Department of Ophthalmology, Counties Manukau DHB, Auckland, New Zealand
| | - Y J Khoo
- Lions Eye Institute, Centre for Ophthalmology and Visual Science, University of Western Australia, Perth, Australia
| | - A G Kermode
- Centre for Neuromuscular and Neurological Disorders, Perron Institute AU, University of Western Australia, Perth, WA, Australia.,Institute for Immunology and Infectious Disease, Murdoch University, Perth, WA, Australia
| | - C R Lind
- Neurosurgical Service of Western Australia, Sir Charles Gairdner Hospital, Nedlands, WA, Australia.,Medical School, University of Western Australia, Perth, Australia
| | - J Dunuwille
- Department of Neurology, Sir Charles Gairdner Hospital, Nedlands, Australia
| | - D Y Yu
- Lions Eye Institute, Centre for Ophthalmology and Visual Science, University of Western Australia, Perth, Australia
| |
Collapse
|
10
|
Onder H. The potential significance of reversed stapes reflex in clinical practice in idiopathic intracranial hypertension. Ann Indian Acad Neurol 2022; 25:214-217. [PMID: 35693648 PMCID: PMC9175437 DOI: 10.4103/aian.aian_379_21] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2021] [Revised: 10/03/2021] [Accepted: 10/11/2021] [Indexed: 11/05/2022] Open
Abstract
Background: Stapes reflex test is a method of evaluating the involuntary muscle contraction of the stapedius muscle in response to a high-intensity sound stimulus. The formation of this reflex involves the intact function of the 7th nerve, brain stem, 8th nerve, and middle ear. Due to ease of administration and information yielded, the stapedial reflex is considered one of the most powerful differential diagnostic audiological procedures. Numerous studies have remarked on the fluid communication between the intracochlear and intracranial spaces through the cochlear aqueduct. Currently, the potential significance of a noninvasive audiological technique in the discrimination of raised intracranial pressure constitutes a crucial topic of interest. Methods: We have performed the pre-LP and post-LP detailed otorhinolaryngological investigations, including the detailed inspection, audiometric testing, tympanometry, and stapedial reflex in a total of four consecutive patients with IIH. Results: We found that the stapedial reflex was bilateral absent initially in two of the patients. However, the second stapedial reflex investigations after LP showed reversal of the reflex responses in both of the patients. Conclusions: We suggest some hypotheses and propose some clinical applications. Future studies focusing on the potential utility of this reflex in the monitorization of IIH may provide crucial perspectives.
Collapse
|
11
|
Dhar R, Sandler RH, Manwaring K, Kostick N, Mansy HA. Noninvasive detection of elevated ICP using spontaneous tympanic membrane pulsation. Sci Rep 2021; 11:21957. [PMID: 34753976 PMCID: PMC8578552 DOI: 10.1038/s41598-021-01079-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2021] [Accepted: 10/12/2021] [Indexed: 11/09/2022] Open
Abstract
Neurological conditions such as traumatic brain injury (TBI) and hydrocephalus may lead to intracranial pressure (ICP) elevation. Current diagnosis methods rely on direct pressure measurement, while CT, MRI and other expensive imaging may be used. However, these invasive or expensive testing methods are often delayed because symptoms of elevated ICP are non-specific. Invasive methods, such as intraventricular catheter, subdural screw, epidural sensor, lumbar puncture, are associated with an increased risk of infection and hemorrhage. On the other hand, noninvasive, low-cost, accurate methods of ICP monitoring can help avoid risks and reduce costs while expediting diagnosis and treatment. The current study proposes and evaluates a novel method for noninvasive ICP monitoring using tympanic membrane pulsation (TMp). These signals are believed to be transmitted from ICP to the auditory system through the cochlear aqueduct. Fifteen healthy subjects were recruited and TMp signals were acquired noninvasively while the subjects performed maneuvers that are known to change ICP. A custom made system utilizing a stethoscope headset and a pressure transducer was used to perform these measurements. Maneuvers included head-up-tilt, head-down-tilt and hyperventilation. When elevated ICP was induced, significant TMp waveform morphological changes were observed in each subject (p < 0.01). These changes include certain waveform slopes and high frequency wave features. The observed changes were reversed by the maneuvers that decreased ICP (p < .01). The study results suggest that TMp waveform measurement and analysis may offer an inexpensive, noninvasive, accurate tool for detection and monitoring of ICP elevations. Further studies are warranted to validate this technique in patients with pathologically elevated ICP.
Collapse
Affiliation(s)
- Rajkumar Dhar
- Biomedical Acoustics Research Laboratory, University of Central Florida, Orlando, FL, 32816, USA.
| | - Richard H Sandler
- Biomedical Acoustics Research Laboratory, University of Central Florida, Orlando, FL, 32816, USA
| | - Kim Manwaring
- Pediatric Neurosurgery, Arnold Palmer Children's Hospital, Orlando, FL, 32806, USA
| | - Nathan Kostick
- College of Medicine, University of Central Florida, Orlando, FL, 32827, USA
| | - Hansen A Mansy
- Biomedical Acoustics Research Laboratory, University of Central Florida, Orlando, FL, 32816, USA
| |
Collapse
|
12
|
Zhang B, Huang Z, Song H, Kim HS, Park J. Wearable Intracranial Pressure Monitoring Sensor for Infants. BIOSENSORS 2021; 11:213. [PMID: 34210050 PMCID: PMC8301997 DOI: 10.3390/bios11070213] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/02/2021] [Revised: 06/26/2021] [Accepted: 06/28/2021] [Indexed: 11/22/2022]
Abstract
Monitoring of intracranial pressure (ICP) is important for patients at risk of raised ICP, which may indicate developing diseases in brains that can lead to brain damage or even death. Monitoring ICP can be invaluable in the management of patients suffering from brain injury or hydrocephalus. To date, invasive measurements are still the standard method for monitoring ICP; however, these methods can not only cause bleeding or infection but are also very inconvenient to use, particularly for infants. Currently, none of the non-invasive methods can provide sufficient accuracy and ease of use while allowing continuous monitoring in routine clinical use at low cost. Here, we have developed a wearable, non-invasive ICP sensor that can be used like a band-aid. For the fabrication of the ICP sensor, a novel freeze casting method was developed to encapsulate the liquid metal microstructures within thin and flexible polymers. The final thickness of the ICP sensor demonstrated is 500 µm and can be further reduced. Three different designs of ICP sensors were tested under various pressure actuation conditions as well as different temperature environments, where the measured pressure changes were stable with the largest stability coefficient of variation being only CV = 0.0206. In addition, the sensor output values showed an extremely high linear correlation (R2 > 0.9990) with the applied pressures.
Collapse
Affiliation(s)
- Baoyue Zhang
- School of Microelectronics, Southern University of Science and Technology, Shenzhen 518055, China; (B.Z.); (Z.H.); (H.S.)
| | - Ziyi Huang
- School of Microelectronics, Southern University of Science and Technology, Shenzhen 518055, China; (B.Z.); (Z.H.); (H.S.)
| | - Huixue Song
- School of Microelectronics, Southern University of Science and Technology, Shenzhen 518055, China; (B.Z.); (Z.H.); (H.S.)
| | - Hyun Soo Kim
- Department of Electronic Engineering, Kwangwoon University, Seoul 01897, Korea
| | - Jaewon Park
- School of Microelectronics, Southern University of Science and Technology, Shenzhen 518055, China; (B.Z.); (Z.H.); (H.S.)
| |
Collapse
|
13
|
Redon S, Elzière M, Donnet A. The neurologist and the hydrops. J Vestib Res 2021; 31:303-309. [PMID: 33843710 DOI: 10.3233/ves-200790] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
The presence of endolymphatic hydrops has been studied in many neurological disorders. The pathophysiological mechanisms may involve CSF pressure variations, transmitted to the innear ear. This hydrops could play a role in vestibular or cochlear symptoms. For the ENT specialist, the etiological diagnosis of endolymphatic hydrops is a challenge, and neurological etiologies must be known. The treatment of these neurological causes could be effective on cochleo-vestibular symptoms. The knowledge of endolymphatic hydrops could also be a target for noninvasive tests, able to estimate CSF pressure variations. For the neurologist, this could represent a useful tool for the diagnosis and follow-up, in some of these neurological disorders, related to a CSF pressure imbalance. The purpose of this paper is to summarize literature data on endolymphatic hydrops in neurological disorders. We define some neurological conditions, for which there is a particular interest in noninvasive investigations of endolymphatic hydrops.
Collapse
Affiliation(s)
- Sylvain Redon
- Department of Evaluation and Treatment of Pain, FHU INOVPAIN, CHU Timone, AP-HM, Marseille, France
| | - Maya Elzière
- Vertigo center, European Hospital, Marseille, France
| | - Anne Donnet
- Department of Evaluation and Treatment of Pain, FHU INOVPAIN, CHU Timone, AP-HM, Marseille, France.,INSERM U-1107, CHU de Clermont-Ferrand, Clermont-Ferrand, France
| |
Collapse
|
14
|
Kostick N, Manwaring K, Dhar R, Sandler R, Mansy H. The "Brain Stethoscope": A Non-Invasive Method for Detecting Elevated Intracranial Pressure. Cureus 2021; 13:e13865. [PMID: 33859914 PMCID: PMC8038910 DOI: 10.7759/cureus.13865] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
Abstract
Introduction Minimally invasive intracranial pressure (ICP) screening has long been desired by neurosurgeons. A novel approach deriving ICP from tympanic membrane (TM) pulsation may offer the solution. The ICP waveform appears to be transmitted to the TM by the cochlear aqueduct. The resulting TM infrasonic pulsations can be measured by certain sensors. Elevated ICP alters brain compliance, which appears to yield slower rise times of the TM pulsation waveform. Measurement of this change may be useful in screening for elevated ICP. This paper investigates one such technique. Methods A stethoscope was modified for airtight external ear canal fit; the dome was exchanged for a magnetic reluctance pressure sensor, allowing measurement of TM pulsations. Analog TM pulsations were analyzed by measuring the pulsation's slope ratio between the waveform's downslope and upslope. Seventeen normal subjects (ages 18-32 years) underwent hyperventilation and tilt table testing to induce ICP changes. An algorithm processed this data and predicted the subject's ICP status. Results The slope ratio method showed consistent and stable changes with the expected alterations in ICP from the tilt test and hyperventilation maneuvers. The classification algorithm correctly identified subjects with elevated ICP in 60 of 60 independent recordings on 17 subjects. Conclusion This paper has four conclusions. First, the "brain stethoscope" can detect increased ICP from the TM pulsation waveform in healthy subjects. Second, analysis of the TM waveform using slope ratio calculations is capable of distinguishing normal versus elevated ICP. Third, the tilt and hyperventilation maneuvers showed the expected physiologic trends. Last, further studies are needed on patients with pathological ICP before the brain stethoscope can be implemented into clinical practice.
Collapse
Affiliation(s)
- Nathan Kostick
- Medicine, University of Central Florida College of Medicine, Orlando, USA
| | - Kim Manwaring
- Pediatric Neurosurgery, Orlando Regional Medical Center, Orlando, USA
| | - Rajkumar Dhar
- Mechanical and Aerospace Engineering, University of Central Florida, Orlando, USA
| | - Richard Sandler
- Pediatric Gastroenterology, Nemours Children's Hospital, Orlando, USA
| | - Hansen Mansy
- Mechanical and Aerospace Engineering, University of Central Florida, Orlando, USA
| |
Collapse
|
15
|
Campbell-Bell CM, Sharif SJ, Zhang T, Bulters D, Marchbanks RJ, Birch AA. A vascular subtraction method for improving the variability of evoked tympanic membrane displacement measurements. Physiol Meas 2021; 42:025001. [PMID: 33508808 DOI: 10.1088/1361-6579/abe0ff] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
OBJECTIVE Evoked tympanic membrane displacement (TMD) measurements show a correlation with intracranial pressure (ICP). Attempts to use these measurements for non-invasive monitoring of ICP in patients have been limited by high measurement variability. Pulsing of the tympanic membrane at the cardiac frequency has been shown to be a significant source of the variability. In this study we describe a post processing method to remove the cardiac pulse waveform and assess the impact of this on the measurement and its repeatability. APPROACH Three-hundred and sixteen healthy volunteers were recruited for evoked TMD measurements. The measurements were quantified by V m, defined as the mean displacement between the point of maximum inward displacement and the end of the stimulus. A sample of spontaneously pulsing TMDs was measured immediately before the evoked measurements. Simultaneous recording of the ECG allowed a heartbeat template to be extracted from the spontaneous data and subtracted from the evoked data. Intra-subject repeatability of V m was assessed from 20 repeats of the evoked measurement. Results with and without subtraction of the heartbeat template were compared. The difference was tested for significance using the Wilcoxon sign rank test. MAIN RESULTS In left and right ears, both sitting and supine, application of the pulse correction significantly reduced the intra-subject variability of V m (p value range 4.0 × 10-27 to 2.0 × 10-31). The average improvement was from 98 ± 6 nl to 56 ± 4 nl. SIGNIFICANCE The pulse subtraction technique substantially improves the repeatability of evoked TMD measurements. This justifies further investigations to assess the use of TMD measurements in clinical applications where non-invasive tracking of changes in ICP would be useful.
Collapse
Affiliation(s)
- C M Campbell-Bell
- Neurological Physics, Department of Medical Physics and Bioengineering, University Hospital Southampton NHS Foundation Trust, Southampton, SO16 6YD, United Kingdom
| | | | | | | | | | | |
Collapse
|
16
|
Canac N, Jalaleddini K, Thorpe SG, Thibeault CM, Hamilton RB. Review: pathophysiology of intracranial hypertension and noninvasive intracranial pressure monitoring. Fluids Barriers CNS 2020; 17:40. [PMID: 32576216 PMCID: PMC7310456 DOI: 10.1186/s12987-020-00201-8] [Citation(s) in RCA: 38] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2020] [Accepted: 06/11/2020] [Indexed: 12/30/2022] Open
Abstract
Measurement of intracranial pressure (ICP) is crucial in the management of many neurological conditions. However, due to the invasiveness, high cost, and required expertise of available ICP monitoring techniques, many patients who could benefit from ICP monitoring do not receive it. As a result, there has been a substantial effort to explore and develop novel noninvasive ICP monitoring techniques to improve the overall clinical care of patients who may be suffering from ICP disorders. This review attempts to summarize the general pathophysiology of ICP, discuss the importance and current state of ICP monitoring, and describe the many methods that have been proposed for noninvasive ICP monitoring. These noninvasive methods can be broken down into four major categories: fluid dynamic, otic, ophthalmic, and electrophysiologic. Each category is discussed in detail along with its associated techniques and their advantages, disadvantages, and reported accuracy. A particular emphasis in this review will be dedicated to methods based on the use of transcranial Doppler ultrasound. At present, it appears that the available noninvasive methods are either not sufficiently accurate, reliable, or robust enough for widespread clinical adoption or require additional independent validation. However, several methods appear promising and through additional study and clinical validation, could eventually make their way into clinical practice.
Collapse
|
17
|
Evensen KB, Eide PK. Measuring intracranial pressure by invasive, less invasive or non-invasive means: limitations and avenues for improvement. Fluids Barriers CNS 2020; 17:34. [PMID: 32375853 PMCID: PMC7201553 DOI: 10.1186/s12987-020-00195-3] [Citation(s) in RCA: 65] [Impact Index Per Article: 16.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2020] [Accepted: 04/19/2020] [Indexed: 12/20/2022] Open
Abstract
Sixty years have passed since neurosurgeon Nils Lundberg presented his thesis about intracranial pressure (ICP) monitoring, which represents a milestone for its clinical introduction. Monitoring of ICP has since become a clinical routine worldwide, and today represents a cornerstone in surveillance of patients with acute brain injury or disease, and a diagnostic of individuals with chronic neurological disease. There is, however, controversy regarding indications, clinical usefulness and the clinical role of the various ICP scores. In this paper, we critically review limitations and weaknesses with the current ICP measurement approaches for invasive, less invasive and non-invasive ICP monitoring. While risk related to the invasiveness of ICP monitoring is extensively covered in the literature, we highlight other limitations in current ICP measurement technologies, including limited ICP source signal quality control, shifts and drifts in zero pressure reference level, affecting mean ICP scores and mean ICP-derived indices. Control of the quality of the ICP source signal is particularly important for non-invasive and less invasive ICP measurements. We conclude that we need more focus on mitigation of the current limitations of today's ICP modalities if we are to improve the clinical utility of ICP monitoring.
Collapse
Affiliation(s)
- Karen Brastad Evensen
- Department of Neurosurgery, Oslo University Hospital-Rikshospitalet, P.O. Box 4950, Nydalen, 0424, Oslo, Norway
- Department of Informatics, Faculty of Mathematics and Natural Sciences, University of Oslo, Oslo, Norway
| | - Per Kristian Eide
- Department of Neurosurgery, Oslo University Hospital-Rikshospitalet, P.O. Box 4950, Nydalen, 0424, Oslo, Norway.
- Institute of Clinical Medicine, Faculty of Medicine, University of Oslo, Oslo, Norway.
| |
Collapse
|
18
|
Padayachy LC, Robba C, Brekken R. Non-invasive assessment of ICP in children: advances in ultrasound-based techniques. Childs Nerv Syst 2020; 36:95-98. [PMID: 31584121 DOI: 10.1007/s00381-019-04371-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/16/2019] [Accepted: 09/03/2019] [Indexed: 11/28/2022]
Abstract
The assessment of intracranial pressure (ICP) in children with neurological disease remains a cornerstone in their routine management. The quest for a reliable, reproducible and radiation-free non-invasive technique for assessing ICP in children remains somewhat of a holy grail for neurosurgery. This work assesses some of the recent advances in ultrasound-based techniques, addressing both novel processes and modifications aimed at improving the accuracy of existing techniques.
Collapse
Affiliation(s)
- Llewellyn C Padayachy
- Department of Neurosurgery, Faculty of Health Sciences, University of Pretoria, Steve Biko Academic Hospital, Pretoria, South Africa.
| | - C Robba
- Department of Anaesthesia and Intensive Care, Ospedale Policlinico San Martino IRCCS, San Martino Policlinico Hospital, IRCCS for Oncology, University of Genoa, Largo Rosanna Benzi, 15, 16100, Genoa, Italy
| | - R Brekken
- Department of Health Research, Medical Technology, SINTEF, Trondheim, Norway
| |
Collapse
|
19
|
Hunt A, Tasker RC, Deep A. Neurocritical care monitoring of encephalopathic children with acute liver failure: A systematic review. Pediatr Transplant 2019; 23:e13556. [PMID: 31407855 DOI: 10.1111/petr.13556] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/04/2019] [Revised: 06/14/2019] [Accepted: 07/04/2019] [Indexed: 12/15/2022]
Abstract
Research on non-invasive neuromonitoring specific to PALF is limited. This systematic review identifies and synthesis the existing literature on non-invasive approaches to monitoring for neurological sequelae in patients with PALF. A series of literature searches were performed to identify all publications pertaining to five different non-invasive neuromonitoring modalities, in line with PRISMA guidelines. Each modality was selected on the basis of its potential for direct or indirect measurement of cerebral perfusion; studies on electroencephalographic monitoring were therefore not sought. Data were recorded on study design, patient population, comparator groups, and outcomes. A preponderance of observational studies was observed, most with a small sample size. Few incorporated direct comparisons of different modalities; in particular, comparison to invasive intracranial pressure monitoring was largely lacking. The integration of current evidence is considered in the context of the clinically significant distinctions between pediatric and adult ALF, as well as the implications for planning of future investigations to best support the evidence-based clinical care of these patients.
Collapse
Affiliation(s)
- Adam Hunt
- University College Hospital, London, UK
| | - Robert C Tasker
- Harvard Medical School, Chair in Neurocritical Care, Boston Children's Hospital, Boston, MA
| | - Akash Deep
- Paediatric Intensive Care, King's College Hospital, London, UK
| |
Collapse
|
20
|
Abstract
PURPOSE OF REVIEW This article focuses on the multiple neuromonitoring devices that can be used to collect bedside data in the neurocritical care unit and the methodology to integrate them into a multimodality monitoring system. The article describes how to apply the collected data to appreciate the physiologic changes and develop therapeutic approaches to prevent secondary injury. RECENT FINDINGS The neurologic examination has served as the primary monitor for secondary brain injury in patients admitted to the neurocritical care unit. However, the International Multidisciplinary Consensus Conference on Multimodality Monitoring in Neurocritical Care concluded that frequent bedside examinations are not sufficient to detect and prevent secondary brain injury and that integration of multimodality monitoring with advanced informatics tools will most likely enhance our assessments compared to the clinical examinations alone. This article reviews the invasive and noninvasive technologies used to monitor focal and global neurophysiologic cerebral alterations. SUMMARY Multimodal monitoring is still in the early stages of development. Research is still needed to establish more advanced monitors with the bioinformatics to identify useful trends from data gathered to predict clinical outcome or prevent secondary brain injury.
Collapse
|
21
|
Evensen KB, Paulat K, Prieur F, Holm S, Eide PK. Utility of the Tympanic Membrane Pressure Waveform for Non-invasive Estimation of The Intracranial Pressure Waveform. Sci Rep 2018; 8:15776. [PMID: 30361489 PMCID: PMC6202360 DOI: 10.1038/s41598-018-34083-6] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2018] [Accepted: 10/11/2018] [Indexed: 11/09/2022] Open
Abstract
Time domain analysis of the intracranial pressure (ICP) waveform provides important information about the intracranial pressure-volume reserve capacity. The aim here was to explore whether the tympanic membrane pressure (TMP) waveform can be used to non-invasively estimate the ICP waveform. Simultaneous invasive ICP and non-invasive TMP signals were measured in a total of 28 individuals who underwent invasive ICP measurements as a part of their clinical work up (surveillance after subarachnoid hemorrhage in 9 individuals and diagnostic for CSF circulation disorders in 19 individuals). For each individual, a transfer function estimate between the invasive ICP and non-invasive TMP signals was established in order to explore the potential of the method. To validate the results, ICP waveform parameters including the mean wave amplitude (MWA) were computed in the time domain for both the ICP estimates and the invasively measured ICP. The patient-specific non-invasive ICP signals predicted MWA rather satisfactorily in 4/28 individuals (14%). In these four patients the differences between original and estimated MWA were <1.0 mmHg in more than 50% of observations, and <0.5 mmHg in more than 20% of observations. The study further disclosed that the cochlear aqueduct worked as a physical lowpass filter.
Collapse
Affiliation(s)
- Karen Brastad Evensen
- Department of Informatics, University of Oslo, Oslo, Norway.,Department of Neurosurgery, Oslo University Hospital - Rikshospitalet, Oslo, Norway
| | - Klaus Paulat
- Institute of Medical Engineering and Mechatronics, Hochschule Ulm, Ulm, Germany
| | - Fabrice Prieur
- Department of Informatics, University of Oslo, Oslo, Norway
| | - Sverre Holm
- Department of Informatics, University of Oslo, Oslo, Norway
| | - Per Kristian Eide
- Department of Neurosurgery, Oslo University Hospital - Rikshospitalet, Oslo, Norway. .,Institute of Clinical Medicine, Faculty of Medicine, University of Oslo, Oslo, Norway.
| |
Collapse
|
22
|
Al-Mufti F, Sursal T, Kim M, Menjivar AM, Cole C, Chandy D, Schmidt M, Bowers C, Gandhi CD. Noninvasive Multimodality Cerebral Monitoring Modalities in Neurosurgical Critical Care. World Neurosurg 2018; 121:249-250. [PMID: 30347294 DOI: 10.1016/j.wneu.2018.10.076] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
Affiliation(s)
- Fawaz Al-Mufti
- Department of Neurology and Neurosurgery, Westchester Medical Center at New York Medical College, Valhalla, New York, USA
| | - Tolga Sursal
- Department of Neurology and Neurosurgery, Westchester Medical Center at New York Medical College, Valhalla, New York, USA
| | - Michael Kim
- Department of Neurology and Neurosurgery, Westchester Medical Center at New York Medical College, Valhalla, New York, USA
| | - Alvaro Martin Menjivar
- Department of Internal Medicine - Division of Critical Care, Westchester Medical Center at New York Medical College, Valhalla, New York, USA
| | - Chad Cole
- Department of Neurology and Neurosurgery, Westchester Medical Center at New York Medical College, Valhalla, New York, USA
| | - Dipak Chandy
- Department of Neurology and Neurosurgery, Westchester Medical Center at New York Medical College, Valhalla, New York, USA; Department of Internal Medicine - Division of Critical Care, Westchester Medical Center at New York Medical College, Valhalla, New York, USA
| | - Meic Schmidt
- Department of Neurology and Neurosurgery, Westchester Medical Center at New York Medical College, Valhalla, New York, USA
| | - Christian Bowers
- Department of Neurology and Neurosurgery, Westchester Medical Center at New York Medical College, Valhalla, New York, USA
| | - Chirag D Gandhi
- Department of Neurology and Neurosurgery, Westchester Medical Center at New York Medical College, Valhalla, New York, USA
| |
Collapse
|
23
|
El-Bouri WK, Vignali D, Iliadi K, Bulters D, Marchbanks RJ, Birch AA, Simpson DM. Quantifying the contribution of intracranial pressure and arterial blood pressure to spontaneous tympanic membrane displacement. Physiol Meas 2018; 39:085002. [PMID: 29999499 DOI: 10.1088/1361-6579/aad308] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
OBJECTIVE Although previous studies have shown associations between patient symptoms/outcomes and the spontaneous tympanic membrane displacement (spTMD) pulse amplitude, the contribution of the underlying intracranial pressure (ICP) signal to the spTMD pulse remains largely unknown. We have assessed the relative contributions of ICP and arterial blood pressure (ABP) on spTMD at different frequencies in order to determine whether spTMD contains information about the ICP above and beyond that contained in the ABP. APPROACH Eleven patients, who all had invasive ICP and ABP measurements in situ, were recruited from our intensive care unit. Their spTMD was recorded and the power spectral densities of the three signals, as well as coherences between the signals, were calculated in the range 0.1-5 Hz. Simple and multiple coherences, coupled with statistical tests using surrogate data, were carried out to quantify the relative contributions of ABP and ICP to spTMD. MAIN RESULTS Most power of the signals was found to predominate at respiration rate, heart rate, and their harmonics, with little outside of these frequencies. Analysis of the simple coherences found a slight preference for ICP transmission, beyond that from ABP, to the spTMD at lower frequencies (7/11 patients at respiration, 7/10 patients at respiration 1st harmonic) which is reversed at the higher frequencies (2/11 patients at heart rate and its 1st harmonic). Both ICP and ABP were found to independently contribute to the spTMD. The multiple coherence reinforced that ICP is preferentially being transmitted at respiration and respiration 1st harmonic. SIGNIFICANCE Both ABP and ICP contribute independently to the spTMD signal, with most power occurring at clear physiological frequencies-respiration and harmonics and heart rate and harmonics. There is information shared between the ICP and spTMD that is not present in ABP. This analysis has indicated that lower frequencies appear to favour ICP as the driver for spTMD.
Collapse
Affiliation(s)
- Wahbi K El-Bouri
- Neurological Physics Group, Department of Medical Physics, University Hospital Southampton NHS Foundation Trust, Southampton, United Kingdom. Institute for Sound and Vibration Research, University of Southampton, Southampton, United Kingdom
| | | | | | | | | | | | | |
Collapse
|
24
|
Al-Mufti F, Smith B, Lander M, Damodara N, Nuoman R, El-Ghanem M, Kamal N, Al-Marsoummi S, Alzubaidi B, Nuoaman H, Foreman B, Amuluru K, Gandhi CD. Novel minimally invasive multi-modality monitoring modalities in neurocritical care. J Neurol Sci 2018; 390:184-192. [PMID: 29801883 DOI: 10.1016/j.jns.2018.03.032] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2017] [Revised: 03/14/2018] [Accepted: 03/25/2018] [Indexed: 11/19/2022]
Abstract
Elevated intracranial pressure (ICP) following brain injury contributes to poor outcomes for patients, primarily by reducing the caliber of cerebral vasculature, and thereby reducing cerebral blood flow. Careful monitoring of ICP is critical in these patients in order to determine prognosis, implement treatment when ICP becomes elevated, and to judge responsiveness to treatment. Currently, the gold standard for monitoring is invasive pressure transducers, usually an intraventricular monitor, which presents significant risk of infection and hemorrhage. These risks made discovering non-invasive methods for monitoring ICP and cerebral perfusion a priority for researchers. Herein we sought to review recent publications on novel minimally invasive multi-modality monitoring techniques that provide surrogate data on ICP, cerebral oxygenation, metabolism and blood flow. While limitations in various forms preclude them from supplanting the use of invasive monitors, these modalities represent useful screening tools within our armamentarium that may be invaluable when the risks of invasive monitoring outweigh the associated benefits.
Collapse
Affiliation(s)
- Fawaz Al-Mufti
- Department of Neurology, Neurosurgery and Radiology, Westchester Medical Center at New York Medical College, Valhalla, NY, United States; Department of Neurosurgery, Rutgers University - New Jersey Medical School, Newark, NJ, United States.
| | - Brendan Smith
- Department of Neurosurgery, Rutgers University - New Jersey Medical School, Newark, NJ, United States
| | - Megan Lander
- Department of Neurosurgery, Rutgers University - New Jersey Medical School, Newark, NJ, United States
| | - Nitesh Damodara
- Department of Neurosurgery, Rutgers University - New Jersey Medical School, Newark, NJ, United States
| | - Rolla Nuoman
- Department of Neurology, Rutgers University - New Jersey Medical School, Newark, NJ, United States
| | - Mohammad El-Ghanem
- Department of Neurosurgery, Rutgers University - New Jersey Medical School, Newark, NJ, United States
| | - Naveed Kamal
- Department of Neurosurgery, Rutgers University - New Jersey Medical School, Newark, NJ, United States
| | - Sarmad Al-Marsoummi
- Department of Biomedical Sciences, University of North Dakota, Grand Forks, ND, United States
| | - Basim Alzubaidi
- Department of Neurology, Neurosurgery and Radiology, Westchester Medical Center at New York Medical College, Valhalla, NY, United States
| | - Halla Nuoaman
- Department of Neurology, Neurosurgery and Radiology, Westchester Medical Center at New York Medical College, Valhalla, NY, United States
| | - Brandon Foreman
- Department of Neurology and Rehabilitation Medicine, Division of Neurocritical Care, University of Cincinnati, Cincinnati, OH, United States
| | - Krishna Amuluru
- Department of Neurointerventional Radiology, University of Pittsburgh, Hamot, Erie, PA, United States
| | - Chirag D Gandhi
- Department of Neurosurgery, Westchester Medical Center - New York Medical College, Valhalla, NY, United States
| |
Collapse
|
25
|
Campbell-Bell CM, Birch AA, Vignali D, Bulters D, Marchbanks RJ. Reference intervals for the evoked tympanic membrane displacement measurement: a non-invasive measure of intracranial pressure. Physiol Meas 2018; 39:015008. [DOI: 10.1088/1361-6579/aaa1d3] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
|
26
|
Liu D, Li Z, Zhang X, Zhao L, Jia J, Sun F, Wang Y, Ma D, Wei W. Assessment of intracranial pressure with ultrasonographic retrobulbar optic nerve sheath diameter measurement. BMC Neurol 2017; 17:188. [PMID: 28962603 PMCID: PMC5622417 DOI: 10.1186/s12883-017-0964-5] [Citation(s) in RCA: 42] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2017] [Accepted: 09/11/2017] [Indexed: 12/05/2022] Open
Abstract
Background Ultrasonograpic retrobulbar optic nerve sheath diameter (ONSD) measurement is considered to be an alternative noninvasive method to estimate intracranial pressure,but the further validation is urgently needed. The aim of the current study was to investigate the association of the ultrasonographic ONSD and intracranial pressure (ICP) in patients. Methods One hundred and ten patients whose intracranial pressure measured via lumbar puncture were enrolled in the study. Their retrobulbar ONSD with B-scan ultrasound was determined just before lumber puncture. The correlation between the ICP and the body mass index (BMI), ONSD or age was established respectively with the Pearson correlation coefficient analysis. The discriminant analysis was used to obtain a discriminant formula for predicting ICP with the ONSD、BMI、gender and age. Another 20 patients were recruited for further validation the efficiency of this discriminant equation. Results The mean ICP was 215.3 ± 81.2 mmH2O. ONSD was 5.70 ± 0.80 mm in the right eye and 5.80 ± 0.77 mm in the left eye. A significant correlation was found between ICP and BMI (r = 0.554, p < 0.001), the mean ONSD (r = 0.61, P < 0.001), but not with age (r = −0.131, p = 0.174) and gender (r = 0.03, p = 0.753). Using receiver operating characteristic (ROC) curve analysis, the critical value for the risk mean-ONSD was 5.6 mm from the ROC curve, with the sensitivity of 86.2% and specificity of 73.1%. With 200 mmH2O as the cutoff point for a high or low ICP, stepwise discriminant was applied, the sensitivity and specificity of ONSD predicting ICP was 84.5%-85.7% and 86.5%-92.3%. Conclusions Ophthalmic ultrasound measurement of ONSD may be a good surrogate of invasive ICP measurement. This non-invasive method may be an alternative approach to predict the ICP value of patients whose ICP measurement via lumbar puncture are in high risk. The discriminant formula, which incorporated the factor of BMI, had similar sensitivity and higher specificity than the ROC curve.
Collapse
Affiliation(s)
- Dachuan Liu
- Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University; Beijing key Laboratory of Intraocular Tumor Diagnosis and Treatment; Beijing Ophthalmology and Visual Sciences Key Lab, Beijing, 100730, China.,Department of Ophthalmology,Xuanwu Hospital, Capital Medical University, Beijing, China
| | - Zhen Li
- Department of Ophthalmology,Xuanwu Hospital, Capital Medical University, Beijing, China
| | - Xuxiang Zhang
- Department of Ophthalmology,Xuanwu Hospital, Capital Medical University, Beijing, China
| | - Liping Zhao
- Department of Ophthalmology,Xuanwu Hospital, Capital Medical University, Beijing, China
| | - Jianping Jia
- Department of Neurology,Xuanwu Hospital, Capital Medical University, Beijing, China
| | - Fei Sun
- Beijing Geriatric Healthcare Center, Beijing, China
| | - Yaxing Wang
- Beijing Institute of Ophthalmology, Beijing, China
| | - Daqing Ma
- Anaesthetics, Pain Medicine and Intensive Care, Department of Surgery and Cancer, Faculty of Medicine, Imperial College London, and Chelsea and Westminster Hospital, London, UK
| | - Wenbin Wei
- Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University; Beijing key Laboratory of Intraocular Tumor Diagnosis and Treatment; Beijing Ophthalmology and Visual Sciences Key Lab, Beijing, 100730, China.
| |
Collapse
|
27
|
Zhang B, Hu H, Ye A, Zhang P. A surface acoustic wave ICP sensor with good temperature stability. Technol Health Care 2017; 25:435-441. [PMID: 28582931 DOI: 10.3233/thc-171346] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND Intracranial pressure (ICP) monitoring is very important for assessing and monitoring hydrocephalus, head trauma and hypertension patients, which could lead to elevated ICP or even devastating neurological damage. The mortality rate due to these diseases could be reduced through ICP monitoring, because precautions can be taken against the brain damage. OBJECTIVE This paper presents a surface acoustic wave (SAW) pressure sensor to realize ICP monitoring, which is capable of wireless and passive transmission with antenna attached. METHODS In order to improve the temperature stability of the sensor, two methods were adopted. First, the ST cut quartz was chosen as the sensor substrate due to its good temperature stability. Then, a differential temperature compensation method was proposed to reduce the effects of temperature. Two resonators were designed based on coupling of mode (COM) theory and the prototype was fabricated and verified using a system established for testing pressure and temperature. RESULTS The experiment result shows that the sensor has a linearity of 2.63% and hysteresis of 1.77%. CONCLUSIONS The temperature stability of the sensor has been greatly improved by using the differential compensation method, which validates the effectiveness of the proposed method.
Collapse
Affiliation(s)
- Bing Zhang
- Department of Mechanical Engineering and Automation, Harbin Institute of Technology Shenzhen Graduate School, Shenzhen, Guangdong, China
| | - Hong Hu
- Department of Mechanical Engineering and Automation, Harbin Institute of Technology Shenzhen Graduate School, Shenzhen, Guangdong, China
| | - Aipeng Ye
- College of Mechatronics and Control Engineering, Shenzhen University, Shenzhen, Guangdong, China
| | - Peng Zhang
- Department of Mechanical Engineering and Automation, Harbin Institute of Technology Shenzhen Graduate School, Shenzhen, Guangdong, China
| |
Collapse
|
28
|
Hirzallah MI, Choi HA. The Monitoring of Brain Edema and Intracranial Hypertension. JOURNAL OF NEUROCRITICAL CARE 2016. [DOI: 10.18700/jnc.160093] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022] Open
|
29
|
Guy AH, Wiggs JL, Turalba A, Pasquale LR. Translating the Low Translaminar Cribrosa Pressure Gradient Hypothesis into the Clinical Care of Glaucoma. Semin Ophthalmol 2016; 31:131-9. [PMID: 26959138 DOI: 10.3109/08820538.2015.1114855] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
Glaucoma is an optic neuropathy with multiple known risk factors, including age, race, family history, and intraocular pressure. Unfortunately, the only currently modifiable risk factor in treating the disease is intraocular pressure (IOP). Recent studies have investigated intracranial pressure (ICP) and the translaminar cribrosa pressure gradient as a potential explanation for glaucomatous optic nerve vulnerability across a range of IOP values. The difference between these two pressures across the lamina cribrosa may have an effect on the optic nerve, which could provide another modifiable parameter in the battle against glaucoma. In order for modification of the translaminar pressure gradient to be considered in the treatment of glaucoma, noninvasive methods to accurately measure ICP need to be developed. The translaminar pressure gradient could be therapeutically adjusted by either further lowering the IOP or raising the ICP when it is pathologically low, if possible.
Collapse
Affiliation(s)
- Ann H Guy
- a Glaucoma Service, Department of Ophthalmology, Massachusetts Eye and Ear Infirmary, Harvard Medical School , Boston , Massachusetts , USA , and
| | - Janey L Wiggs
- a Glaucoma Service, Department of Ophthalmology, Massachusetts Eye and Ear Infirmary, Harvard Medical School , Boston , Massachusetts , USA , and
| | - Angela Turalba
- a Glaucoma Service, Department of Ophthalmology, Massachusetts Eye and Ear Infirmary, Harvard Medical School , Boston , Massachusetts , USA , and
| | - Louis R Pasquale
- a Glaucoma Service, Department of Ophthalmology, Massachusetts Eye and Ear Infirmary, Harvard Medical School , Boston , Massachusetts , USA , and.,b Channing Division of Network Medicine, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School , Boston , Massachusetts , USA
| |
Collapse
|
30
|
Abstract
Assessing intracranial pressure (ICP) remains a cornerstone in neurosurgical care. Invasive techniques for monitoring ICP remain the gold standard. The need for a reliable, safe and reproducible technique to non-invasively assess ICP in the context of early screening and in the neurocritical care environment is obvious. Numerous techniques have been described with several novel advances. While none of the currently available techniques appear independently accurate enough to quantify raised ICP, there is some promising work being undertaken.
Collapse
|
31
|
Robba C, Bacigaluppi S, Cardim D, Donnelly J, Bertuccio A, Czosnyka M. Non-invasive assessment of intracranial pressure. Acta Neurol Scand 2016; 134:4-21. [PMID: 26515159 DOI: 10.1111/ane.12527] [Citation(s) in RCA: 81] [Impact Index Per Article: 10.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/01/2015] [Indexed: 11/29/2022]
Abstract
Monitoring of intracranial pressure (ICP) is invaluable in the management of neurosurgical and neurological critically ill patients. Invasive measurement of ventricular or parenchymal pressure is considered the gold standard for accurate measurement of ICP but is not always possible due to certain risks. Therefore, the availability of accurate methods to non-invasively estimate ICP has the potential to improve the management of these vulnerable patients. This review provides a comparative description of different methods for non-invasive ICP measurement. Current methods are based on changes associated with increased ICP, both morphological (assessed with magnetic resonance, computed tomography, ultrasound, and fundoscopy) and physiological (assessed with transcranial and ophthalmic Doppler, tympanometry, near-infrared spectroscopy, electroencephalography, visual-evoked potentials, and otoacoustic emissions assessment). At present, none of the non-invasive techniques alone seem suitable as a substitute for invasive monitoring. However, following the present analysis and considerations upon each technique, we propose a possible flowchart based on the combination of non-invasive techniques including those characterizing morphologic changes (e.g., repetitive US measurements of ONSD) and those characterizing physiological changes (e.g., continuous TCD). Such an integrated approach, which still needs to be validated in clinical practice, could aid in deciding whether to place an invasive monitor, or how to titrate therapy when invasive ICP measurement is contraindicated or unavailable.
Collapse
Affiliation(s)
- C. Robba
- Neurosciences Critical Care Unit; Addenbrooke's Hospital; Cambridge United Kingdom
- Brain Physics Lab; Division of Neurosurgery; Department of Clinical Neurosciences; University of Cambridge; United Kingdom
| | - S. Bacigaluppi
- Department of Neurosurgery; Galliera Hospital; Genova Italy
| | - D. Cardim
- Brain Physics Lab; Division of Neurosurgery; Department of Clinical Neurosciences; University of Cambridge; United Kingdom
| | - J. Donnelly
- Brain Physics Lab; Division of Neurosurgery; Department of Clinical Neurosciences; University of Cambridge; United Kingdom
| | - A. Bertuccio
- Department of Neurosurgery; S. George's Hospital; University of London; United Kingdom
| | - M. Czosnyka
- Brain Physics Lab; Division of Neurosurgery; Department of Clinical Neurosciences; University of Cambridge; United Kingdom
| |
Collapse
|
32
|
Noninvasive Brain Physiology Monitoring for Extreme Environments: A Critical Review. J Neurosurg Anesthesiol 2016; 27:318-28. [PMID: 25811362 DOI: 10.1097/ana.0000000000000175] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
Our ability to monitor the brain physiology is advancing; however, most of the technology is bulky, expensive, and designed for traditional clinical settings. With long-duration space exploration, there is a need for developing medical technologies that are reliable, low energy, portable, and semiautonomous. Our aim was to review the state of the art for noninvasive technologies capable of monitoring brain physiology in diverse settings. A literature review of PubMed and the Texas Medical Center library sites was performed using prespecified search criteria to identify portable technologies for monitoring physiological aspects of the brain physiology. Most brain-monitoring technologies require a moderate to high degree of operator skill. Some are low energy, but many require a constant external power supply. Most of the technologies lack the accuracy seen in gold standard measures, due to the need for calibration, but may be useful for screening or monitoring relative changes in a parameter. Most of the technologies use ultrasound or electromagnetic radiation as energy sources. There is an important need for further development of portable technologies that can be operated in a variety of extreme environments to monitor brain health.
Collapse
|
33
|
Can intracranial pressure be measured non-invasively bedside using a two-depth Doppler-technique? J Clin Monit Comput 2016; 31:459-467. [DOI: 10.1007/s10877-016-9862-4] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2015] [Accepted: 03/08/2016] [Indexed: 10/22/2022]
|
34
|
Cardim D, Robba C, Donnelly J, Bohdanowicz M, Schmidt B, Damian M, Varsos GV, Liu X, Cabeleira M, Frigieri G, Cabella B, Smielewski P, Mascarenhas S, Czosnyka M. Prospective Study on Noninvasive Assessment of Intracranial Pressure in Traumatic Brain-Injured Patients: Comparison of Four Methods. J Neurotrauma 2015; 33:792-802. [PMID: 26414916 DOI: 10.1089/neu.2015.4134] [Citation(s) in RCA: 61] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023] Open
Abstract
Elevation of intracranial pressure (ICP) may occur in many diseases, and therefore the ability to measure it noninvasively would be useful. Flow velocity signals from transcranial Doppler (TCD) have been used to estimate ICP; however, the relative accuracy of these methods is unclear. This study aimed to compare four previously described TCD-based methods with directly measured ICP in a prospective cohort of traumatic brain-injured patients. Noninvasive ICP (nICP) was obtained using the following methods: 1) a mathematical "black-box" model based on interaction between TCD and arterial blood pressure (nICP_BB); 2) based on diastolic flow velocity (nICP_FVd); 3) based on critical closing pressure (nICP_CrCP); and 4) based on TCD-derived pulsatility index (nICP_PI). In time domain, for recordings including spontaneous changes in ICP greater than 7 mm Hg, nICP_PI showed the best correlation with measured ICP (R = 0.61). Considering every TCD recording as an independent event, nICP_BB generally showed to be the best estimator of measured ICP (R = 0.39; p < 0.05; 95% confidence interval [CI] = 9.94 mm Hg; area under the curve [AUC] = 0.66; p < 0.05). For nICP_FVd, although it presented similar correlation coefficient to nICP_BB and marginally better AUC (0.70; p < 0.05), it demonstrated a greater 95% CI for prediction of ICP (14.62 mm Hg). nICP_CrCP presented a moderate correlation coefficient (R = 0.35; p < 0.05) and similar 95% CI to nICP_BB (9.19 mm Hg), but failed to distinguish between normal and raised ICP (AUC = 0.64; p > 0.05). nICP_PI was not related to measured ICP using any of the above statistical indicators. We also introduced a new estimator (nICP_Av) based on the average of three methods (nICP_BB, nICP_FVd, and nICP_CrCP), which overall presented improved statistical indicators (R = 0.47; p < 0.05; 95% CI = 9.17 mm Hg; AUC = 0.73; p < 0.05). nICP_PI appeared to reflect changes in ICP in time most accurately. nICP_BB was the best estimator for ICP "as a number." nICP_Av demonstrated to improve the accuracy of measured ICP estimation.
Collapse
Affiliation(s)
- Danilo Cardim
- 1 Brain Physics Laboratory, Division of Neurosurgery, Department of Clinical Neurosciences, University of Cambridge , Cambridge, United Kingdom
| | - Chiara Robba
- 2 Neurosciences Critical Care Unit, Addenbrooke's Hospital, Cambridge University Hospitals NHS Foundation Trust , Cambridge, United Kingdom
| | - Joseph Donnelly
- 1 Brain Physics Laboratory, Division of Neurosurgery, Department of Clinical Neurosciences, University of Cambridge , Cambridge, United Kingdom
| | - Michal Bohdanowicz
- 3 Institute of Electronic Systems, Warsaw University of Technology , Warsaw, Poland
| | - Bernhard Schmidt
- 4 Department of Neurology, University Hospital Chemnitz , Chemnitz, Germany
| | - Maxwell Damian
- 5 Department of Neurology, Addenbrooke's Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge, United Kingdom
| | - Georgios V Varsos
- 1 Brain Physics Laboratory, Division of Neurosurgery, Department of Clinical Neurosciences, University of Cambridge , Cambridge, United Kingdom
| | - Xiuyun Liu
- 1 Brain Physics Laboratory, Division of Neurosurgery, Department of Clinical Neurosciences, University of Cambridge , Cambridge, United Kingdom
| | - Manuel Cabeleira
- 1 Brain Physics Laboratory, Division of Neurosurgery, Department of Clinical Neurosciences, University of Cambridge , Cambridge, United Kingdom
| | - Gustavo Frigieri
- 6 University of Sao Paulo , Physics Institute of Sao Carlos, Sao Carlos, Sao Paulo, Brazil
| | - Brenno Cabella
- 1 Brain Physics Laboratory, Division of Neurosurgery, Department of Clinical Neurosciences, University of Cambridge , Cambridge, United Kingdom
| | - Peter Smielewski
- 1 Brain Physics Laboratory, Division of Neurosurgery, Department of Clinical Neurosciences, University of Cambridge , Cambridge, United Kingdom
| | - Sergio Mascarenhas
- 6 University of Sao Paulo , Physics Institute of Sao Carlos, Sao Carlos, Sao Paulo, Brazil
| | - Marek Czosnyka
- 1 Brain Physics Laboratory, Division of Neurosurgery, Department of Clinical Neurosciences, University of Cambridge , Cambridge, United Kingdom .,3 Institute of Electronic Systems, Warsaw University of Technology , Warsaw, Poland
| |
Collapse
|
35
|
Abstract
Neuromonitoring aims to detect harmful physiologic events, early enough to guide the treatment instituted. Evidences encourage us to implement multimodal monitoring, as no single monitor is capable of providing a complete picture of dynamic cerebral state. This review highlights the role of intracranial pressure monitoring, cerebral oxygenation (jugular venous oximetry, brain tissue oxygenation, near infrared oximetry, cerebral microdialysis) and cerebral blood flow monitoring (direct and indirect methods) in the management of neurologically injured patients. In this context, the recent developments of these monitors along with the relevant clinical implications have been discussed. Nevertheless, the diverse range of data obtained from these monitors needs to be integrated and simplified for the clinician. Hence, the future research should focus on identification of a most useful monitor for integration into multimodal system.
Collapse
Affiliation(s)
- Charu Mahajan
- Department of Neuroanaesthesiology, All India Institute of Medical Sciences, New Delhi, India
| | - Girija Prasad Rath
- Department of Neuroanaesthesiology, All India Institute of Medical Sciences, New Delhi, India
| | - Parmod Kumar Bithal
- Department of Neuroanaesthesiology, All India Institute of Medical Sciences, New Delhi, India
| |
Collapse
|
36
|
Siaudvytyte L, Januleviciene I, Ragauskas A, Bartusis L, Siesky B, Harris A. Update in intracranial pressure evaluation methods and translaminar pressure gradient role in glaucoma. Acta Ophthalmol 2015; 93:9-15. [PMID: 25043873 DOI: 10.1111/aos.12502] [Citation(s) in RCA: 45] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2014] [Accepted: 06/15/2014] [Indexed: 01/24/2023]
Abstract
Glaucoma is one of the leading causes of blindness worldwide. Historically, it has been considered an ocular disease primary caused by pathological intraocular pressure (IOP). Recently, researchers have emphasized intracranial pressure (ICP), as translaminar counter pressure against IOP may play a role in glaucoma development and progression. It remains controversial what is the best way to measure ICP in glaucoma. Currently, the 'gold standard' for ICP measurement is invasive measurement of the pressure in the cerebrospinal fluid via lumbar puncture or via implantation of the pressure sensor into the brains ventricle. However, the direct measurements of ICP are not without risk due to its invasiveness and potential risk of intracranial haemorrhage and infection. Therefore, invasive ICP measurements are prohibitive due to safety needs, especially in glaucoma patients. Several approaches have been proposed to estimate ICP non-invasively, including transcranial Doppler ultrasonography, tympanic membrane displacement, ophthalmodynamometry, measurement of optic nerve sheath diameter and two-depth transcranial Doppler technology. Special emphasis is put on the two-depth transcranial Doppler technology, which uses an ophthalmic artery as a natural ICP sensor. It is the only method which accurately and precisely measures absolute ICP values and may provide valuable information in glaucoma.
Collapse
Affiliation(s)
- Lina Siaudvytyte
- Eye Clinic Lithuanian University of Health Sciences Kaunas Lithuania
| | | | - Arminas Ragauskas
- Health Telematics Science Centre of Kaunas University of Technology Kaunas Lithuania
| | - Laimonas Bartusis
- Eye Clinic Lithuanian University of Health Sciences Kaunas Lithuania
- Health Telematics Science Centre of Kaunas University of Technology Kaunas Lithuania
| | - Brent Siesky
- Glaucoma Research and Diagnostic Center Eugene and Marilyn Glick Eye Institute Indiana University School of Medicine Indianapolis IN USA
| | - Alon Harris
- Eye Clinic Lithuanian University of Health Sciences Kaunas Lithuania
- Glaucoma Research and Diagnostic Center Eugene and Marilyn Glick Eye Institute Indiana University School of Medicine Indianapolis IN USA
| |
Collapse
|
37
|
Abstract
Objectives:To investigate the feasibility of Electroencephalogram (EEG) power spectrum analysis as a noninvasive method for monitoring intracranial pressure (ICP).Methods:The EEG signals were recorded in 62 patients (70 cases) with central nervous system (CNS) disorders in our hospital. By using self-designed software, EEG power spectrum analysis was conducted and pressure index (PI) was calculated automatically. Intracranial pressure was measured by lumbar puncture (LP).Results:We found a significant negative correlation between PI and ICP (r = -0.849, p < 0.01).Conclusions:The PI obtained from EEG analysis is correlated with ICP. Analysis of specific parameters from EEG power spectrum might reflect the ICP.
Collapse
|
38
|
Affiliation(s)
- Mark H. Wilson
- The Brain Injury Centre—St Mary's Hospital, Imperial College, London, United Kingdom
- Birmingham Medical Research Expeditionary Society, Birmingham, United Kingdom
- The Institute of Pre-Hospital Care, London's Air Ambulance, Barts and the London Medical School, Queen Mary University of London, The Helipad, The Royal London Hospital, Whitechapel, United Kingdom
| | - Alex Wright
- Birmingham Medical Research Expeditionary Society, Birmingham, United Kingdom
| | - Christopher H.E. Imray
- University Hospital Coventry and Warwickshire NHS Trust and Warwick Medical School, Coventry, United Kingdom
| |
Collapse
|
39
|
|
40
|
Gwer S, Sheward V, Birch A, Marchbanks R, Idro R, Newton CR, Kirkham FJ, Lin JP, Lim M. The tympanic membrane displacement analyser for monitoring intracranial pressure in children. Childs Nerv Syst 2013; 29:927-33. [PMID: 23361337 PMCID: PMC3657347 DOI: 10.1007/s00381-013-2036-5] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/04/2013] [Accepted: 01/15/2013] [Indexed: 12/23/2022]
Abstract
PURPOSE Raised intracranial pressure (ICP) is a potentially treatable cause of morbidity and mortality but tools for monitoring are invasive. We sought to investigate the utility of the tympanic membrane displacement (TMD) analyser for non-invasive measurement of ICP in children. METHODS We made TMD observations on normal and acutely comatose children presenting to Kilifi District Hospital (KDH) at the rural coast of Kenya and on children on follow-up for idiopathic intracranial hypertension at Evelina Children's Hospital (ECH), in London, UK. RESULTS We recruited 63 patients (median age 3.3 (inter-quartile range (IQR) 2.0-4.3) years) at KDH and 14 children (median age 10 (IQR 5-11) years) at ECH. We observed significantly higher (more negative) TMD measurements in KDH children presenting with coma compared to normal children seen at the hospital's outpatient department, in both semi-recumbent [mean -61.3 (95 % confidence interval (95 % CI) -93.5 to 29.1) nl versus mean -7.1 (95 % CI -54.0 to 68.3) nl, respectively; P = 0.03] and recumbent postures [mean -61.4 (95 % CI -93.4 to -29.3) nl, n = 59) versus mean -25.9 (95 % CI -71.4 to 123.2) nl, respectively; P = 0.03]. We also observed higher TMD measurements in ECH children with raised ICP measurements, as indicated by lumbar puncture manometry, compared to those with normal ICP, in both semi-recumbent [mean -259.3 (95 % CI -363.8 to -154.8) nl versus mean 26.7 (95 % CI -52.3 to 105.7) nl, respectively; P < 0.01] and recumbent postures [mean -137.5 (95 % CI -260.6 to -14.4) nl versus mean 96.6 (95 % CI 6.5 to 186.6) nl, respectively; P < 0.01]. CONCLUSION The TMD analyser has a potential utility in monitoring ICP in a variety of clinical circumstances.
Collapse
Affiliation(s)
- Samson Gwer
- Department of Medical Physiology, School of Health Sciences, Kenyatta University, Nairobi, Kenya.
| | - Victoria Sheward
- Paediatric Neurosciences, Evelina Children’s Hospital, Guy’s and St. Thomas’ NHS Foundation Trust, King’s Health Partners AHSC, London, UK
| | - Anthony Birch
- Neurological Physics Group, Department of Medical Physics and Bioengineering, University Hospital Southampton NHS Foundation Trust, Southampton, UK
| | - Robert Marchbanks
- Neurological Physics Group, Department of Medical Physics and Bioengineering, University Hospital Southampton NHS Foundation Trust, Southampton, UK
| | - Richard Idro
- Centre For Geographic Medicine Research, Kenya Medical Research Institute, Kilifi, Kenya ,Department of Paediatrics and Child Health, Mulago Hospital, Makerere University College of Health Sciences, Kampala, Uganda
| | - Charles R. Newton
- Centre For Geographic Medicine Research, Kenya Medical Research Institute, Kilifi, Kenya ,Department of Psychiatry, Oxford University, Oxford, UK ,Neurosciences Unit, The Wolfson Centre, Institute of Child Health, University College of London, London, UK
| | - Fenella J. Kirkham
- Neurosciences Unit, The Wolfson Centre, Institute of Child Health, University College of London, London, UK ,Department of Child Health, Southampton University Hospital NHS Trust, Southampton, UK
| | - Jean-Pierre Lin
- Paediatric Neurosciences, Evelina Children’s Hospital, Guy’s and St. Thomas’ NHS Foundation Trust, King’s Health Partners AHSC, London, UK
| | - Ming Lim
- Paediatric Neurosciences, Evelina Children’s Hospital, Guy’s and St. Thomas’ NHS Foundation Trust, King’s Health Partners AHSC, London, UK
| |
Collapse
|
41
|
Raboel PH, Bartek J, Andresen M, Bellander BM, Romner B. Intracranial Pressure Monitoring: Invasive versus Non-Invasive Methods-A Review. Crit Care Res Pract 2012; 2012:950393. [PMID: 22720148 PMCID: PMC3376474 DOI: 10.1155/2012/950393] [Citation(s) in RCA: 144] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2011] [Revised: 02/28/2012] [Accepted: 03/27/2012] [Indexed: 02/06/2023] Open
Abstract
Monitoring of intracranial pressure (ICP) has been used for decades in the fields of neurosurgery and neurology. There are multiple techniques: invasive as well as noninvasive. This paper aims to provide an overview of the advantages and disadvantages of the most common and well-known methods as well as assess whether noninvasive techniques (transcranial Doppler, tympanic membrane displacement, optic nerve sheath diameter, CT scan/MRI and fundoscopy) can be used as reliable alternatives to the invasive techniques (ventriculostomy and microtransducers). Ventriculostomy is considered the gold standard in terms of accurate measurement of pressure, although microtransducers generally are just as accurate. Both invasive techniques are associated with a minor risk of complications such as hemorrhage and infection. Furthermore, zero drift is a problem with selected microtransducers. The non-invasive techniques are without the invasive methods' risk of complication, but fail to measure ICP accurately enough to be used as routine alternatives to invasive measurement. We conclude that invasive measurement is currently the only option for accurate measurement of ICP.
Collapse
Affiliation(s)
- P. H. Raboel
- Department of Neurosurgery, Copenhagen University Hospital Rigshospitalet, DK-2100, Copenhagen, Denmark
| | - J. Bartek
- Department of Neurosurgery, Copenhagen University Hospital Rigshospitalet, DK-2100, Copenhagen, Denmark
- Department of Neurosurgery, Karolinska University Hospital, SE-17176, Stockholm, Sweden
| | - M. Andresen
- Department of Neurosurgery, Copenhagen University Hospital Rigshospitalet, DK-2100, Copenhagen, Denmark
| | - B. M. Bellander
- Department of Neurosurgery, Karolinska University Hospital, SE-17176, Stockholm, Sweden
| | - B. Romner
- Department of Neurosurgery, Copenhagen University Hospital Rigshospitalet, DK-2100, Copenhagen, Denmark
| |
Collapse
|
42
|
Budohoski KP, Schmidt B, Smielewski P, Kasprowicz M, Plontke R, Pickard JD, Klingelhöfer J, Czosnyka M. Non-invasively estimated ICP pulse amplitude strongly correlates with outcome after TBI. ACTA NEUROCHIRURGICA. SUPPLEMENT 2012; 114:121-5. [PMID: 22327676 DOI: 10.1007/978-3-7091-0956-4_22] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/03/2022]
Abstract
INTRODUCTION An existing monitoring database of brain signal recordings in patients with head injury has been re-evaluated with regard to the accuracy of estimation of non-invasive ICP (nICP) and its components, with a particular interest in the implications for outcome after head injury. METHODS Middle cerebral artery blood flow velocity (FV), ICP and arterial blood pressure (ABP) were recorded. Non-invasive ICP (nICP) was calculated using a mathematical model. Other signals analysed included components of ICP (n" indicates non-invasive): ICP pulse amplitude (Amp, nAmp), amplitude of the respiratory component (Resp, nResp), amplitude of slow vasogenic waves of ICP (Slow, nSlow) and index of compensatory reserve (RAP, nRAP). Mean values of analysed signals were compared against each other and between patients who died and survived. RESULTS The correlation between ICP and nICP was moderately strong, R = 0.51 (95% prediction interval [PI] 17 mm Hg). The components of nICP and ICP were also moderately correlated with each other: the strongest correlation was observed for Resp vs. nResp (r = 0.66), while weaker for Amp vs. nAmp (r = 0.41). Non-invasive pulse amplitude of ICP showed the strongest association with outcome, with the -difference between those who survived and those who died reaching a significance level of p < 0.000001. DISCUSSION When compared between patients who died and who survived mean nAmp showed the greatest difference, suggesting its potential to predict mortality after TBI.
Collapse
Affiliation(s)
- Karol P Budohoski
- Department of Clinical Neurosciences, Addenbrooke's Hospital, Cambridge, UK.
| | | | | | | | | | | | | | | |
Collapse
|
43
|
Abstract
The rapid diagnosis of intracranial hypertension is urgently needed for therapeutic reasons in various clinical settings. This can rarely be achieved without invasive procedures such as intracranial pressure (ICP) monitoring or neuroimaging. The optic nerve is surrounded by cerebrospinal fluid (CSF) and dura mater, which forms the optic nerve sheath (ONS). Because of the connection with the intracranial subarachnoid space, ONS diameter (ONSD) is influenced by CSF pressure variations. Bedside ultrasonographic measurement of ONSD has been proposed as a non-invasive and reliable means to detect raised ICP in neurocritically ill patients. In several studies, it proves to have a good correlation with the direct measurement of ICP and a low interobserver variability. However, no general consensus exists over the upper normal ONSD limit. We performed a review of the literature on the use of the ultrasonography of the optic nerve in the evaluation of patients with suspected intracranial hypertension. The aim of this review is to describe the technique and to assess the validity of this diagnostic method.
Collapse
Affiliation(s)
- R Moretti
- Department of Anesthesia and Critical Care, Ospedale SS Antonio e Biagio e Cesare Arrigo, Alessandria, Italy
| | | |
Collapse
|
44
|
Posture systematically alters ear-canal reflectance and DPOAE properties. Hear Res 2010; 263:43-51. [PMID: 20227475 DOI: 10.1016/j.heares.2010.03.003] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/14/2009] [Revised: 02/27/2010] [Accepted: 03/02/2010] [Indexed: 02/06/2023]
Abstract
Several studies have demonstrated that the auditory system is sensitive to changes in posture, presumably through changes in intracranial pressure (ICP) that in turn alter the intracochlear pressure, which affects the stiffness of the middle-ear system. This observation has led to efforts to develop an ear-canal based noninvasive diagnostic measure for monitoring ICP, which is currently monitored invasively via access through the skull or spine. Here, we demonstrate the effects of postural changes, and presumably ICP changes, on distortion product otoacoustic emissions (DPOAE) magnitude, DPOAE angle, and power reflectance. Measurements were made on 12 normal-hearing subjects in two postural positions: upright at 90 degrees and tilted at -45 degrees to the horizontal. Measurements on each subject were repeated five times across five separate measurement sessions. All three measures showed significant changes (p<0.001) between upright and tilted for frequencies between 500 and 2000 Hz, and DPOAE angle changes were significant at all measured frequencies (500-4000 Hz). Intra-subject variability, assessed via standard deviations for each subject's multiple measurements, were generally smaller in the upright position relative to the tilted position.
Collapse
|
45
|
Stocchetti N. Could intracranial pressure in traumatic brain injury be measured or predicted noninvasively? Almost. Intensive Care Med 2007; 33:1682-3. [PMID: 17668183 DOI: 10.1007/s00134-007-0798-5] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2007] [Accepted: 06/30/2007] [Indexed: 10/23/2022]
|
46
|
Abstract
Raised intracranial pressure (ICP) and low cerebral blood flow (CBF) are associated with ischaemia and poor outcome after brain injury. Therefore, many management protocols target these parameters. This overview summarizes the technical aspects of ICP and CBF monitoring, and their role in the clinical management of brain-injured patients. Furthermore, some applications of these methods in current research are highlighted. ICP is typically measured using probes that are inserted into one of the lateral ventricles or the brain parenchyma. Therapeutic measures used to control ICP have relevant side-effects and continuous monitoring is essential to guide such therapies. ICP is also required to calculate cerebral perfusion pressure which is one of the most important therapeutic targets in brain-injured patients. Several bedside CBF monitoring devices are available. However, most do not measure CBF but rather a parameter that is thought to be proportional to CBF. Frequently used methods include transcranial Doppler which measures blood flow velocity and may be helpful for the diagnosis and monitoring of cerebral vasospasm after subarachnoid haemorrhage or jugular bulb oximetry which gives information on adequacy of CBF in relation to the metabolic demand of the brain. However, there is no clear evidence that incorporating data from CBF monitors into our management strategies improves outcome in brain-injured patients.
Collapse
Affiliation(s)
- L A Steiner
- Surgical Intensive Care Unit, Department of Anaesthesia, University Hospital Basel, CH-4031 Basel, Switzerland.
| | | |
Collapse
|