Prats-Boluda G, Guillem MS, Rodrigo M, Ye-Lin Y, Garcia-Casado J. Identification of atrial fibrillation drivers by means of concentric ring electrodes. Comput Biol Med 2022; 148:105957. [PMID: 35981454 DOI: 10.1016/j.compbiomed.2022.105957] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2022] [Revised: 07/19/2022] [Accepted: 08/06/2022] [Indexed: 11/16/2022]
Abstract
BACKGROUND AND OBJECTIVE The prevalence of atrial fibrillation (AF) has tripled in the last 50 years due to population aging. High-frequency (DFdriver) activated atrial regions lead the activation of the rest of the atria, disrupting the propagation wavefront. Fourier based spectral analysis of body surface potential maps have been proposed for DFdriver identification, although these approaches present serious drawbacks due to their limited spectral resolution for short AF epochs and the blurring effect of the volume conductor. Laplacian signals (BC-ECG) from bipolar concentric ring electrodes (CRE) have been shown to outperform the spatial resolution achieved with conventional unipolar recordings. Our aimed was to determine the best DFdriver estimator in endocardial electrograms and to assess the BC-ECG capacity of CRE to quantify AF activity non-invasively. METHODS 31 AF episodes were simulated using realistic tridimensional models of the atria electrical activity and torso. Periodogram and autoregressive (AR) spectral estimators were computed and the percentile (P90th, P95th and P98th) to impose on the dominant frequencies (DFs) across whole atria to define the best DFdriver estimator evaluated. The identification of DFdriver on DFs from BC-ECG and unipolar surface signals with conventional disc electrodes was compared. RESULTS The best DFdriver estimator was P95th and AR order 100. BC-ECG signals allowed better detection of AF activity than unipolar signals, with a significantly greater percentage of electrode locations in which DFdriver was identified (p-value 0.0095). CONCLUSIONS The use of BC-ECG signals for body surface Laplacian potential mapping with CRE could be helpful for better AF diagnosis, prognosis and ablation procedures than those with conventional disk electrodes.
Collapse
Affiliation(s)
- Gema Prats-Boluda
- Centro de Investigación e Innovación en Bioingeniería, Universitat Politècnica de València, Valencia, Spain.
| | - María S Guillem
- ITACA Institute, Universitat Politècnica de València, Valencia, Spain.
| | - Miguel Rodrigo
- CommLab, Engineering Electronic Department, Universitat de València, Valencia, Spain.
| | - Yiyao Ye-Lin
- Centro de Investigación e Innovación en Bioingeniería, Universitat Politècnica de València, Valencia, Spain.
| | - Javier Garcia-Casado
- Centro de Investigación e Innovación en Bioingeniería, Universitat Politècnica de València, Valencia, Spain.
| |
Collapse
|
2
|
Makeyev O, Ye-Lin Y, Prats-Boluda G, Garcia-Casado J. Comprehensive Optimization of the Tripolar Concentric Ring Electrode Based on Its Finite Dimensions Model and Confirmed by Finite Element Method Modeling. SENSORS 2021; 21:s21175881. [PMID: 34502772 PMCID: PMC8434583 DOI: 10.3390/s21175881] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/31/2021] [Revised: 08/13/2021] [Accepted: 08/28/2021] [Indexed: 11/16/2022]
Abstract
The optimization performed in this study is based on the finite dimensions model of the concentric ring electrode as opposed to the negligible dimensions model used in the past. This makes the optimization problem comprehensive, as all of the electrode parameters including, for the first time, the radius of the central disc and individual widths of concentric rings, are optimized simultaneously. The optimization criterion used is maximizing the accuracy of the surface Laplacian estimation, as the ability to estimate the Laplacian at each electrode constitutes primary biomedical significance of concentric ring electrodes. For tripolar concentric ring electrodes, the optimal configuration was compared to previously proposed linearly increasing inter-ring distances and constant inter-ring distances configurations of the same size and based on the same finite dimensions model. The obtained analytic results suggest that previously proposed configurations correspond to almost two-fold and more than three-fold increases in the Laplacian estimation error compared with the optimal configuration proposed in this study, respectively. These analytic results are confirmed using finite element method modeling, which was adapted to the finite dimensions model of the concentric ring electrode for the first time. Moreover, the finite element method modeling results suggest that optimal electrode configuration may also offer improved sensitivity and spatial resolution.
Collapse
Affiliation(s)
- Oleksandr Makeyev
- School of STEM, Diné College, Tsaile, AZ 86556, USA
- Correspondence: ; Tel.: +1-928-724-6960
| | - Yiyao Ye-Lin
- Centro de Investigación e Innovación en Bioingeniería, Universitat Politècnica de València, 46022 Valencia, Spain; (Y.Y.-L.); (G.P.-B.); (J.G.-C.)
| | - Gema Prats-Boluda
- Centro de Investigación e Innovación en Bioingeniería, Universitat Politècnica de València, 46022 Valencia, Spain; (Y.Y.-L.); (G.P.-B.); (J.G.-C.)
| | - Javier Garcia-Casado
- Centro de Investigación e Innovación en Bioingeniería, Universitat Politècnica de València, 46022 Valencia, Spain; (Y.Y.-L.); (G.P.-B.); (J.G.-C.)
| |
Collapse
|
3
|
Estrada-Petrocelli L, Torres A, Sarlabous L, Rafols-de-Urquia M, Ye-Lin Y, Prats-Boluda G, Jane R, Garcia-Casado J. Evaluation of Respiratory Muscle Activity by Means of Concentric Ring Electrodes. IEEE Trans Biomed Eng 2020; 68:1005-1014. [PMID: 32746073 DOI: 10.1109/tbme.2020.3012385] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Surface electromyography (sEMG) can be used for the evaluation of respiratory muscle activity. Recording sEMG involves the use of surface electrodes in a bipolar configuration. However, electrocardiographic (ECG) interference and electrode orientation represent considerable drawbacks to bipolar acquisition. As an alternative, concentric ring electrodes (CREs) can be used for sEMG acquisition and offer great potential for the evaluation of respiratory muscle activity due to their enhanced spatial resolution and simple placement protocol, which does not depend on muscle fiber orientation. The aim of this work was to analyze the performance of CREs during respiratory sEMG acquisitions. Respiratory muscle sEMG was applied to the diaphragm and sternocleidomastoid muscles using a bipolar and a CRE configuration. Thirty-two subjects underwent four inspiratory load spontaneous breathing tests which was repeated after interchanging the electrode positions. We calculated parameters such as (1) spectral power and (2) median frequency during inspiration, and power ratios of inspiratory sEMG without ECG in relation to (3) basal sEMG without ECG (Rins/noise), (4) basal sEMG with ECG (Rins/cardio) and (5) expiratory sEMG without ECG (Rins/exp). Spectral power, Rins/noise and Rins/cardio increased with the inspiratory load. Significantly higher values (p < 0.05) of Rins/cardio and significantly higher median frequencies were obtained for CREs. Rins/noise and Rins/exp were higher for the bipolar configuration only in diaphragm sEMG recordings, whereas no significant differences were found in the sternocleidomastoid recordings. Our results suggest that the evaluation of respiratory muscle activity by means of sEMG can benefit from the remarkably reduced influence of cardiac activity, the enhanced detection of the shift in frequency content and the axial isotropy of CREs which facilitates its placement.
Collapse
|
4
|
Rafols-de-Urquia M, Estevez-Piorno J, Estrada L, Garcia-Casado J, Prats-Boluda G, Sarlabous L, Jane R, Torres A. Assessment of Respiratory Muscle Activity with Surface Electromyographic Signals Acquired by Concentric Ring Electrodes. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2019; 2018:3350-3353. [PMID: 30441106 DOI: 10.1109/embc.2018.8512953] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
The assessment of respiratory muscle activity by surface electromyography (sEMG) is a promising noninvasive technique for the diagnosis and monitoring of chronic obstructive pulmonary disease. The diaphragm is the most important muscle in breathing, although in forced inspiration other muscles, such as sternocleidomastoid, are activated and contribute to the respiratory process. The measurement of the sEMG in these muscles (sEMGdi and sEMGscm, respectively) by means of two electrodes in conventional bipolar configuration (BEs) is a common practice to evaluate the respiratory muscle activity and allows to indirectly quantify the level of muscular activation. However, the resulting signals are usually contaminated by electrocardiographic (ECG) activity, hindering the assessment of the activity of these muscles. sEMG signals can also be recorded using concentric ring electrodes (CREs). CREs have greater spatial resolution and attenuate distant bioelectrical interferences. In this scenario, the objective of this work has been to evaluate the applicability of CREs for the acquisition of sEMGdi and sEMGscm. For this purpose, both sEMG signals were recorded simultaneously with BEs and CREs in healthy subjects while performing an inspiratory load protocol. To evaluate the effect of the cardiac interference, the ratio between the mean power in inspiratory segments without ECG and the mean power in expiratory segments with ECG (Rcardio) was calculated. Additionally, the ratio between the mean power in inspiratory segments without ECG and the mean power in expiratory segments without ECG (Rinex) was also calculated. The results revealed that the Rcardio and bandwidth is greater in sEMG signals acquired with the CREs, while the Rinex is higher in the signals acquired with BEs. These results suggest that the use of CREs is a recommended alternative for the acquisition of sEMG in muscles with high cardiac interference, such as the diaphragm muscle.
Collapse
|
5
|
Evaluation of Bipolar, Tripolar, and Quadripolar Laplacian Estimates of Electrocardiogram via Concentric Ring Electrodes. SENSORS 2019; 19:s19173780. [PMID: 31480426 PMCID: PMC6749387 DOI: 10.3390/s19173780] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/31/2019] [Revised: 08/22/2019] [Accepted: 08/28/2019] [Indexed: 12/17/2022]
Abstract
Surface Laplacian estimates via concentric ring electrodes (CREs) have proven to enhance spatial resolution compared to conventional disc electrodes, which is of great importance for P-wave analysis. In this study, Laplacian estimates for traditional bipolar configuration (BC), two tripolar configurations with linearly decreasing and increasing inter-ring distances (TCLDIRD and TCLIIRD, respectively), and quadripolar configuration (QC) were obtained from cardiac recordings with pentapolar CREs placed at CMV1 and CMV2 positions. Normalized P-wave amplitude (NAP) was computed to assess the contrast to study atrial activity. Signals were of good quality (20-30 dB). Atrial activity was more emphasized at CMV1 (NAP ≃ 0.19-0.24) compared to CMV2 (NAP ≃ 0.08-0.10). Enhanced spatial resolution of TCLIIRD and QC resulted in higher NAP values than BC and TCLDIRD. Comparison with simultaneous standard 12-lead ECG proved that Laplacian estimates at CMV1 outperformed all the limb and chest standard leads in the contrast to study P-waves. Clinical recordings with CRE at this position could allow more detailed observation of atrial activity and facilitate the diagnosis of associated pathologies. Furthermore, such recordings would not require additional electrodes on limbs and could be performed wirelessly, so it should also be suitable for ambulatory monitoring, for example, using cardiac Holter monitors.
Collapse
|
6
|
Makeyev O. Solving the general inter-ring distances optimization problem for concentric ring electrodes to improve Laplacian estimation. Biomed Eng Online 2018; 17:117. [PMID: 30165898 PMCID: PMC6117945 DOI: 10.1186/s12938-018-0549-6] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2018] [Accepted: 08/23/2018] [Indexed: 12/28/2022] Open
Abstract
Background Superiority of noninvasive tripolar concentric ring electrodes over conventional disc electrodes in accuracy of surface Laplacian estimation has been demonstrated in a range of electrophysiological measurement applications. Recently, a general approach to Laplacian estimation for an (n + 1)-polar electrode with n rings using the (4n + 1)-point method has been proposed and used to introduce novel multipolar and variable inter-ring distances electrode configurations. While only linearly increasing and linearly decreasing inter-ring distances have been considered previously, this paper defines and solves the general inter-ring distances optimization problem for the (4n + 1)-point method. Results General inter-ring distances optimization problem is solved for tripolar (n = 2) and quadripolar (n = 3) concentric ring electrode configurations through minimizing the truncation error of Laplacian estimation. For tripolar configuration with middle ring radius αr and outer ring radius r the optimal range of values for α was determined to be 0 < α ≤ 0.22 while for quadripolar configuration with an additional middle ring with radius βr the optimal range of values for α and β was determined by inequalities 0 < α < β < 1 and αβ ≤ 0.21. Finite element method modeling and full factorial analysis of variance were used to confirm statistical significance of Laplacian estimation accuracy improvement due to optimization of inter-ring distances (p < 0.0001). Conclusions Obtained results suggest the potential of using optimization of inter-ring distances to improve the accuracy of surface Laplacian estimation via concentric ring electrodes. Identical approach can be applied to solving corresponding inter-ring distances optimization problems for electrode configurations with higher numbers of concentric rings. Solutions of the proposed inter-ring distances optimization problem define the class of the optimized inter-ring distances electrode designs. These designs may result in improved noninvasive sensors for measurement systems that use concentric ring electrodes to acquire electrical signals such as from the brain, intestines, heart or uterus for diagnostic purposes.
Collapse
Affiliation(s)
- Oleksandr Makeyev
- Department of Mathematics, Diné College, 1 Circle Dr, Tsaile, AZ, 86556, USA.
| |
Collapse
|
7
|
Textile Concentric Ring Electrodes for ECG Recording Based on Screen-Printing Technology. SENSORS 2018; 18:s18010300. [PMID: 29361722 PMCID: PMC5796388 DOI: 10.3390/s18010300] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/29/2017] [Revised: 01/16/2018] [Accepted: 01/17/2018] [Indexed: 11/17/2022]
Abstract
Among many of the electrode designs used in electrocardiography (ECG), concentric ring electrodes (CREs) are one of the most promising due to their enhanced spatial resolution. Their development has undergone a great push due to their use in recent years; however, they are not yet widely used in clinical practice. CRE implementation in textiles will lead to a low cost, flexible, comfortable, and robust electrode capable of detecting high spatial resolution ECG signals. A textile CRE set has been designed and developed using screen-printing technology. This is a mature technology in the textile industry and, therefore, does not require heavy investments. Inks employed as conductive elements have been silver and a conducting polymer (poly (3,4-ethylenedioxythiophene) polystyrene sulfonate; PEDOT:PSS). Conducting polymers have biocompatibility advantages, they can be used with flexible substrates, and they are available for several printing technologies. CREs implemented with both inks have been compared by analyzing their electric features and their performance in detecting ECG signals. The results reveal that silver CREs present a higher average thickness and slightly lower skin-electrode impedance than PEDOT:PSS CREs. As for ECG recordings with subjects at rest, both CREs allowed the uptake of bipolar concentric ECG signals (BC-ECG) with signal-to-noise ratios similar to that of conventional ECG recordings. Regarding the saturation and alterations of ECGs captured with textile CREs caused by intentional subject movements, silver CREs presented a more stable response (fewer saturations and alterations) than those of PEDOT:PSS. Moreover, BC-ECG signals provided higher spatial resolution compared to conventional ECG. This improved spatial resolution was manifested in the identification of P1 and P2 waves of atrial activity in most of the BC-ECG signals. It can be concluded that textile silver CREs are more suitable than those of PEDOT:PSS for obtaining BC-ECG records. These developed textile electrodes bring the use of CREs closer to the clinical environment.
Collapse
|
8
|
Wang K, Parekh U, Pailla T, Garudadri H, Gilja V, Ng TN. Stretchable Dry Electrodes with Concentric Ring Geometry for Enhancing Spatial Resolution in Electrophysiology. Adv Healthc Mater 2017; 6. [PMID: 28714587 DOI: 10.1002/adhm.201700552] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2017] [Revised: 06/13/2017] [Indexed: 11/05/2022]
Abstract
The multichannel concentric-ring electrodes are stencil printed on stretchable elastomers modified to improve adhesion to skin and minimize motion artifacts for electrophysiological recordings of electroencephalography, electromyography, and electrocardiography. These dry electrodes with a poly(3,4-ethylenedioxythiophene) polystyrene sulfonate interface layer are optimized to show lower noise level than that of commercial gel disc electrodes. The concentric ring geometry enables Laplacian filtering to pinpoint the bioelectric potential source with spatial resolution determined by the ring distance. This work shows a new fabrication approach to integrate and create designs that enhance spatial resolution for high-quality electrophysiology monitoring devices.
Collapse
Affiliation(s)
- Kaiping Wang
- Department of Electrical and Computer Engineering; University of California San Diego; 9500 Gilman Drive La Jolla CA 92093-0407 USA
| | - Udit Parekh
- Department of Electrical and Computer Engineering; University of California San Diego; 9500 Gilman Drive La Jolla CA 92093-0407 USA
| | - Tejaswy Pailla
- Department of Electrical and Computer Engineering; University of California San Diego; 9500 Gilman Drive La Jolla CA 92093-0407 USA
| | - Harinath Garudadri
- Department of Electrical and Computer Engineering; University of California San Diego; 9500 Gilman Drive La Jolla CA 92093-0407 USA
| | - Vikash Gilja
- Department of Electrical and Computer Engineering; University of California San Diego; 9500 Gilman Drive La Jolla CA 92093-0407 USA
| | - Tse Nga Ng
- Department of Electrical and Computer Engineering; University of California San Diego; 9500 Gilman Drive La Jolla CA 92093-0407 USA
| |
Collapse
|
9
|
Makeyev O, Besio WG. Improving the Accuracy of Laplacian Estimation with Novel Variable Inter-Ring Distances Concentric Ring Electrodes. SENSORS 2016; 16:s16060858. [PMID: 27294933 PMCID: PMC4934284 DOI: 10.3390/s16060858] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/26/2016] [Revised: 06/02/2016] [Accepted: 06/07/2016] [Indexed: 12/30/2022]
Abstract
Noninvasive concentric ring electrodes are a promising alternative to conventional disc electrodes. Currently, the superiority of tripolar concentric ring electrodes over disc electrodes, in particular, in accuracy of Laplacian estimation, has been demonstrated in a range of applications. In our recent work, we have shown that accuracy of Laplacian estimation can be improved with multipolar concentric ring electrodes using a general approach to estimation of the Laplacian for an (n + 1)-polar electrode with n rings using the (4n + 1)-point method for n ≥ 2. This paper takes the next step toward further improving the Laplacian estimate by proposing novel variable inter-ring distances concentric ring electrodes. Derived using a modified (4n + 1)-point method, linearly increasing and decreasing inter-ring distances tripolar (n = 2) and quadripolar (n = 3) electrode configurations are compared to their constant inter-ring distances counterparts. Finite element method modeling and analytic results are consistent and suggest that increasing inter-ring distances electrode configurations may decrease the truncation error resulting in more accurate Laplacian estimates compared to respective constant inter-ring distances configurations. For currently used tripolar electrode configuration, the truncation error may be decreased more than two-fold, while for the quadripolar configuration more than a six-fold decrease is expected.
Collapse
Affiliation(s)
| | - Walter G Besio
- Department of Electrical, Computer, and Biomedical Engineering, University of Rhode Island, Kingston, RI 02881, USA.
| |
Collapse
|
10
|
Enhancement of non-invasive recording of electroenterogram by means of a flexible array of concentric ring electrodes. Ann Biomed Eng 2014; 42:651-60. [PMID: 24232692 DOI: 10.1007/s10439-013-0935-y] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2013] [Accepted: 11/05/2013] [Indexed: 01/30/2023]
Abstract
Monitoring intestinal myoelectrical activity by electroenterogram (EEnG) would be of great clinical interest for diagnosing gastrointestinal pathologies and disorders. However, surface EEnG recordings are of very low amplitude and can be severely affected by baseline drifts and respiratory and electrocardiographic (ECG) interference. In this work, a flexible array of concentric ring electrodes was developed and tested to determine whether it can provide surface EEnG signals of better quality than bipolar recordings from conventional disc electrodes. With this aim, sixteen healthy subjects in a fasting state (>8 h) underwent recording. The capability of detecting intestinal pacemaker activity (slow wave) and the influence of physiological interferences were studied. The signals obtained from the concentric ring electrodes proved to be more robust to ECG and respiratory interference than those from conventional disc electrodes. The results also show that intestinal EEnG components such as the slow wave can be more easily identified by the proposed system based on a flexible array of concentric ring electrodes. The developed active electrode array could be a very valuable tool for non-invasive diagnosis of disease states such as ischemia and motility disorders of the small bowel which are known to alter the normal enteric slow wave activity.
Collapse
|
11
|
Active concentric ring electrode for non-invasive detection of intestinal myoelectric signals. Med Eng Phys 2010; 33:446-55. [PMID: 21163682 DOI: 10.1016/j.medengphy.2010.11.009] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2009] [Revised: 11/10/2010] [Accepted: 11/15/2010] [Indexed: 01/14/2023]
Abstract
Although the surface electroenterogram (EEnG) is a weak signal contaminated by strong physiological interference, such as ECG and respiration, abdominal surface recordings of the EEnG could provide a non-invasive method of studying intestinal activity. The goal of this work was to develop a modular, active, low-cost and easy-to-use sensor to obtain a direct estimation of the Laplacian of the EEnG on the abdominal surface in order to enhance the quality of bipolar surface monitoring of intestinal activity. The sensor is made up of a set of 3 concentric dry Ag/AgCl ring electrodes and a battery-powered signal-conditioning circuit. Each section is etched on a different printed circuit board (PCB) and the sections are joined to each other by surface mount technology connectors. This means the sensing electrodes can be treated independently for purposes of maintenance and replacement and the signal conditioning circuit can be re-used. A total of ten recording sessions were carried out on humans. The results show that the surface recordings of the EEnG obtained by the active sensor present significantly less ECG and respiration interference than those obtained by bipolar recordings. In addition, bioelectrical sources whose frequency fitted with the slow wave component of the EEnG (SW) were identified by parametric spectral analysis in the surface signals picked up by the active sensors.
Collapse
|
12
|
Chen T, Besio W, Dai W. Computer simulation comparison of tripolar, bipolar, and spline Laplacian electrocadiogram estimators. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2009; 2009:3286-3289. [PMID: 19964294 DOI: 10.1109/iembs.2009.5333741] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
A comparison of the performance of the tripolar and bipolar concentric as well as spline Laplacian electrocardiograms (LECGs) and body surface Laplacian mappings (BSLMs) for localizing and imaging the cardiac electrical activation has been investigated based on computer simulation. In the simulation a simplified eccentric heart-torso sphere-cylinder homogeneous volume conductor model were developed. Multiple dipoles with different orientations were used to simulate the underlying cardiac electrical activities. Results show that the tripolar concentric ring electrodes produce the most accurate LECG and BSLM estimation among the three estimators with the best performance in spatial resolution.
Collapse
Affiliation(s)
- T Chen
- Louisiana Tech University, Department of Biomedical Engineering, LA, USA.
| | | | | |
Collapse
|