1
|
Lee H, Johnson Z, Denton S, Liu N, Akinwande D, Porter E, Kireev D. A non-invasive approach to skin cancer diagnosis via graphene electrical tattoos and electrical impedance tomography. Physiol Meas 2024; 45:055003. [PMID: 38599226 DOI: 10.1088/1361-6579/ad3d26] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2023] [Accepted: 04/10/2024] [Indexed: 04/12/2024]
Abstract
Objective.Making up one of the largest shares of diagnosed cancers worldwide, skin cancer is also one of the most treatable. However, this is contingent upon early diagnosis and correct skin cancer-type differentiation. Currently, methods for early detection that are accurate, rapid, and non-invasive are limited. However, literature demonstrating the impedance differences between benign and malignant skin cancers, as well as between different types of skin cancer, show that methods based on impedance differentiation may be promising.Approach.In this work, we propose a novel approach to rapid and non-invasive skin cancer diagnosis that leverages the technologies of difference-based electrical impedance tomography (EIT) and graphene electronic tattoos (GETs).Main results.We demonstrate the feasibility of this first-of-its-kind system using both computational numerical and experimental skin phantom models. We considered variations in skin cancer lesion impedance, size, shape, and position relative to the electrodes and evaluated the impact of using individual and multi-electrode GET (mGET) arrays. The results demonstrate that this approach has the potential to differentiate based on lesion impedance, size, and position, but additional techniques are needed to determine shape.Significance.In this way, the system proposed in this work, which combines both EIT and GET technology, exhibits potential as an entirely non-invasive and rapid approach to skin cancer diagnosis.
Collapse
Affiliation(s)
- Hannah Lee
- Chandra Family Department of Electrical and Computer Engineering, The University of Texas at Austin, Austin, TX, United States of America
| | - Zane Johnson
- McKetta Department of Chemical Engineering, The University of Texas at Austin, Austin, TX, United States of America
| | - Spencer Denton
- Chandra Family Department of Electrical and Computer Engineering, The University of Texas at Austin, Austin, TX, United States of America
| | - Ning Liu
- Chandra Family Department of Electrical and Computer Engineering, The University of Texas at Austin, Austin, TX, United States of America
| | - Deji Akinwande
- Chandra Family Department of Electrical and Computer Engineering, The University of Texas at Austin, Austin, TX, United States of America
- Microelectronics Research Center, The University of Texas at Austin, Austin, TX, United States of America
| | - Emily Porter
- Chandra Family Department of Electrical and Computer Engineering, The University of Texas at Austin, Austin, TX, United States of America
- Department of Biomedical Engineering, McGill University, Montreal, Canada
| | - Dmitry Kireev
- Chandra Family Department of Electrical and Computer Engineering, The University of Texas at Austin, Austin, TX, United States of America
- Microelectronics Research Center, The University of Texas at Austin, Austin, TX, United States of America
- Department of Biomedical Engineering, The University of Massachusetts Amherst, Amherst, MA, United States of America
| |
Collapse
|
2
|
Bajrami D, Zubiaga A, Renggli T, Kirsch C, Spano F, Fehr D, von Schulthess P, Lindhorst‐Peters A, Huber S, Roider E, Rossi RM, Navarini AA, Bonmarin M. Variations of skin thermal diffusivity on different skin regions. Skin Res Technol 2024; 30:e13622. [PMID: 38500350 PMCID: PMC10948952 DOI: 10.1111/srt.13622] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2024] [Accepted: 02/23/2024] [Indexed: 03/20/2024]
Abstract
BACKGROUND AND OBJECTIVE Skin thermal diffusivity plays a crucial role in various applications, including laser therapy and cryogenic skin cooling.This study investigates the correlation between skin thermal diffusivity and two important skin parameters, melanin content and erythema, in a cohort of 102 participants. METHODS An in-house developed device based on transient temperature measurement was used to assess thermal diffusivity at different body locations. Melanin content and erythema were measured using a colorimeter. Statistical analysis was performed to examine potential correlations. RESULTS The results showed that the measured thermal diffusivity values were consistent with previous reports, with variations observed among subjects. No significant correlation was found between thermal diffusivity and melanin content or erythema. This suggests that other factors, such as skin hydration or epidermis thickness, may have a more dominant influence on skin thermal properties. CONLCUSION This research provides valuable insights into the complex interplay between skin thermal properties and physiological parameters, with potential implications for cosmetic and clinical dermatology applications.
Collapse
Affiliation(s)
- Dardan Bajrami
- School of EngineeringZurich University of Applied Sciences (ZHAW)WinterthurSwitzerland
- Dermatology ClinicUniversity Hospital BaselUniversitäre Altersmedizin Felix PlatterBaselSwitzerland
| | - Asier Zubiaga
- School of EngineeringZurich University of Applied Sciences (ZHAW)WinterthurSwitzerland
| | - Timon Renggli
- Dermatology ClinicUniversity Hospital BaselUniversitäre Altersmedizin Felix PlatterBaselSwitzerland
| | - Christoph Kirsch
- School of EngineeringZurich University of Applied Sciences (ZHAW)WinterthurSwitzerland
| | - Fabrizio Spano
- School of EngineeringZurich University of Applied Sciences (ZHAW)WinterthurSwitzerland
| | - Daniel Fehr
- School of EngineeringZurich University of Applied Sciences (ZHAW)WinterthurSwitzerland
| | | | - Alisa Lindhorst‐Peters
- Dermatology ClinicUniversity Hospital BaselUniversitäre Altersmedizin Felix PlatterBaselSwitzerland
| | - Stephanie Huber
- Dermatology ClinicUniversity Hospital BaselUniversitäre Altersmedizin Felix PlatterBaselSwitzerland
| | - Elisabeth Roider
- Dermatology ClinicUniversity Hospital BaselUniversitäre Altersmedizin Felix PlatterBaselSwitzerland
| | - René M. Rossi
- Empa, Swiss Federal Laboratories for Materials Science and TechnologyLaboratory for Biomimetic Membranes and TextilesSt. GallenSwitzerland
| | - Alexander A. Navarini
- Dermatology ClinicUniversity Hospital BaselUniversitäre Altersmedizin Felix PlatterBaselSwitzerland
| | - Mathias Bonmarin
- School of EngineeringZurich University of Applied Sciences (ZHAW)WinterthurSwitzerland
| |
Collapse
|
3
|
Ollmar S, Fernandez Schrunder A, Birgersson U, Kristoffersson T, Rusu A, Thorsson E, Hedenqvist P, Manell E, Rydén A, Jensen-Waern M, Rodriguez S. A battery-less implantable glucose sensor based on electrical impedance spectroscopy. Sci Rep 2023; 13:18122. [PMID: 37872272 PMCID: PMC10593792 DOI: 10.1038/s41598-023-45154-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2023] [Accepted: 10/17/2023] [Indexed: 10/25/2023] Open
Abstract
The ability to perform accurate continuous glucose monitoring without blood sampling has revolutionised the management of diabetes. Newer methods that can allow measurements during longer periods are necessary to substantially improve patients' quality of life. This paper presents an alternative method for glucose monitoring which is based on electrical impedance spectroscopy. A battery-less implantable bioimpedance spectroscope was designed, built, and used in an in vivo study on pigs. After a recovery period of 14 days post surgery, a total of 236 subcutaneous bioimpedance measurements obtained from intravenous glucose tolerance tests, with glucose concentration ranges between 77.4 and 523.8 mg/dL, were analyzed. The results show that glucose concentrations estimated by subcutaneous bioimpedance measurements correlate very well to the blood glucose reference values. The pigs were clinically healthy throughout the study, and the postmortem examinations revealed no signs of adverse effects related to the sensor. The implantation of the sensor requires minor surgery. The implant, being externally powered, could in principle last indefinitely. These encouraging results demonstrate the potential of the bioimpedance method to be used in future continuous glucose monitoring systems.
Collapse
Affiliation(s)
- Stig Ollmar
- Department of Clinical Science, Intervention and Technology, Karolinska Institute, Stockholm, Sweden
| | | | - Ulrik Birgersson
- Department of Clinical Science, Intervention and Technology, Karolinska Institute, Stockholm, Sweden
| | | | - Ana Rusu
- School of Electrical Engineering and Computer Science, KTH Royal Institute of Technology, 16440, Kista, Sweden
| | - Elina Thorsson
- Pathology Unit, Department of Biomedical Science and Veterinary Public Health, Swedish University of Agricultural Sciences, Uppsala, Sweden
| | - Patricia Hedenqvist
- Department of Clinical Sciences, Swedish University of Agricultural Sciences, Uppsala, Sweden
| | - Elin Manell
- Department of Clinical Sciences, Swedish University of Agricultural Sciences, Uppsala, Sweden
| | - Anneli Rydén
- Department of Clinical Sciences, Swedish University of Agricultural Sciences, Uppsala, Sweden
| | - Marianne Jensen-Waern
- Department of Clinical Sciences, Swedish University of Agricultural Sciences, Uppsala, Sweden
| | - Saul Rodriguez
- School of Electrical Engineering and Computer Science, KTH Royal Institute of Technology, 16440, Kista, Sweden.
| |
Collapse
|
4
|
Lo Presti A, Montoya NA, Criscuolo V, Khan G, Khan U, Vecchione R, Falconi C. Fundamentals of Skin Bioimpedances. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2023; 35:e2302127. [PMID: 37252818 DOI: 10.1002/adma.202302127] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/06/2023] [Revised: 05/14/2023] [Indexed: 06/01/2023]
Abstract
The bioimpedances of tissues beyond the stratum corneum, which is the outermost layer of skin, contain crucial clinical information. Nevertheless, bioimpedance measurements of both the viable skin and the adipose tissue are not widely used, mainly because of the complex multilayered skin structure and the electrically insulating nature of the stratum corneum. Here, a theoretical framework is established for analyzing the impedances of multilayered tissues and, in particular, of skin. Then, strategies are determined for the system-level design of electrodes and electronics, which minimize 4-wire (or tetrapolar) measurement errors even in the presence of a top insulating tissue, thus enabling non-invasive characterizations of tissues beyond the stratum corneum. As an example, non-invasive measurements of bioimpedances of living tissues are demonstrated in the presence of parasitic impedances which are much (e.g., up to 350 times) higher than the bioimpedances of the living tissues beyond the stratum corneum, independently on extreme variations of the barrier (tape stripping) or of the skin-electrode contact impedances (sweat). The results can advance the development of bioimpedance systems for the characterization of viable skin and adipose tissues in several applications, including transdermal drug delivery and the assessment of skin cancer, obesity, dehydration, type 2 diabetes mellitus, cardiovascular risk, and multipotent adult stem cells.
Collapse
Affiliation(s)
- Andrea Lo Presti
- Department of Electronic Engineering, University of Rome Tor Vergata, Via del Politecnico 1, Roma, 00133, Italy
| | - Nerio Andrés Montoya
- Department of Electronic Engineering, University of Rome Tor Vergata, Via del Politecnico 1, Roma, 00133, Italy
- School of Physics, Universidad Nacional de Colombia, Medellín, A. A. 3840, Colombia
| | - Valeria Criscuolo
- Department of Electronic Engineering, University of Rome Tor Vergata, Via del Politecnico 1, Roma, 00133, Italy
- Center for Advanced Biomaterial for Health Care, Istituto Italiano di Tecnologia, Largo Barsanti e Matteucci 53, Naples, 80125, Italy
- Faculty of Electrical Engineering and IT, RWTH Aachen, 52062, Aachen, Germany
- Institute for Biological Information Processing - Bioelectronics, IBI-3, Forschungszentrum Juelich, 52428, Aachen, Germany
| | - Gulaly Khan
- School of Electrical Engineering and Computer Science, National University of Sciences and Technology, Sector H-12, Islamabad, 44000, Pakistan
| | - Usman Khan
- School of Electrical Engineering and Computer Science, National University of Sciences and Technology, Sector H-12, Islamabad, 44000, Pakistan
| | - Raffaele Vecchione
- Center for Advanced Biomaterial for Health Care, Istituto Italiano di Tecnologia, Largo Barsanti e Matteucci 53, Naples, 80125, Italy
| | - Christian Falconi
- Department of Electronic Engineering, University of Rome Tor Vergata, Via del Politecnico 1, Roma, 00133, Italy
| |
Collapse
|
5
|
Aggas JR, Abasi S, Ton C, Salehi S, Liu R, Brandacher G, Grayson WL, Guiseppi-Elie A. Real-Time Monitoring Using Multiplexed Multi-Electrode Bioelectrical Impedance Spectroscopy for the Stratification of Vascularized Composite Allografts: A Perspective on Predictive Analytics. Bioengineering (Basel) 2023; 10:bioengineering10040434. [PMID: 37106621 PMCID: PMC10135882 DOI: 10.3390/bioengineering10040434] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2023] [Revised: 03/20/2023] [Accepted: 03/24/2023] [Indexed: 04/29/2023] Open
Abstract
Vascularized composite allotransplantation addresses injuries to complex anatomical structures such as the face, hand, and abdominal wall. Prolonged static cold storage of vascularized composite allografts (VCA) incurs damage and imposes transportation limits to their viability and availability. Tissue ischemia, the major clinical indication, is strongly correlated with negative transplantation outcomes. Machine perfusion and normothermia can extend preservation times. This perspective introduces multiplexed multi-electrode bioimpedance spectroscopy (MMBIS), an established bioanalytical method to quantify the interaction of the electrical current with tissue components, capable of measuring tissue edema, as a quantitative, noninvasive, real-time, continuous monitoring technique to provide crucially needed assessment of graft preservation efficacy and viability. MMBIS must be developed, and appropriate models explored to address the highly complex multi-tissue structures and time-temperature changes of VCA. Combined with artificial intelligence (AI), MMBIS can serve to stratify allografts for improvement in transplantation outcomes.
Collapse
Affiliation(s)
- John R Aggas
- Bioelectronics, Biosensors and Biochips (C3B®), Department of Biomedical Engineering, Department of Electrical and Computer Engineering, Texas A&M University, College Station, TX 77843, USA
- Test Development, Roche Diagnostics, 9115 Hague Road, Indianapolis, IN 46256, USA
| | - Sara Abasi
- Bioelectronics, Biosensors and Biochips (C3B®), Department of Biomedical Engineering, Department of Electrical and Computer Engineering, Texas A&M University, College Station, TX 77843, USA
- Media and Metabolism, Wildtype, Inc., 2325 3rd St., San Francisco, CA 94107, USA
| | - Carolyn Ton
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21231, USA
- Translational Tissue Engineering Center, Johns Hopkins University, Baltimore, MD 21231, USA
| | - Sara Salehi
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21231, USA
- Translational Tissue Engineering Center, Johns Hopkins University, Baltimore, MD 21231, USA
| | - Renee Liu
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21231, USA
- Translational Tissue Engineering Center, Johns Hopkins University, Baltimore, MD 21231, USA
| | - Gerald Brandacher
- Translational Tissue Engineering Center, Johns Hopkins University, Baltimore, MD 21231, USA
- Department of Plastic & Reconstructive Surgery, Johns Hopkins University, Baltimore, MD 21218, USA
| | - Warren L Grayson
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21231, USA
- Translational Tissue Engineering Center, Johns Hopkins University, Baltimore, MD 21231, USA
- Department of Chemical and Biomolecular Engineering, Johns Hopkins University, Baltimore, MD 21218, USA
- Department of Materials Science and Engineering, Johns Hopkins University, Baltimore, MD 21218, USA
- Institute for Nanobiotechnology, Johns Hopkins University, Baltimore, MD 21218, USA
| | - Anthony Guiseppi-Elie
- Bioelectronics, Biosensors and Biochips (C3B®), Department of Biomedical Engineering, Department of Electrical and Computer Engineering, Texas A&M University, College Station, TX 77843, USA
- Department of Cardiovascular Sciences, Houston Methodist Institute for Academic Medicine and Houston Methodist Research Institute, 6670 Bertner Ave., Houston, TX 77030, USA
- ABTECH Scientific, Inc., Biotechnology Research Park, 800 East Leigh Street, Richmond, VA 23219, USA
| |
Collapse
|
6
|
Malyško-Ptašinskė V, Staigvila G, Novickij V. Invasive and non-invasive electrodes for successful drug and gene delivery in electroporation-based treatments. Front Bioeng Biotechnol 2023; 10:1094968. [PMID: 36727038 PMCID: PMC9885012 DOI: 10.3389/fbioe.2022.1094968] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2022] [Accepted: 12/28/2022] [Indexed: 01/17/2023] Open
Abstract
Electroporation is an effective physical method for irreversible or reversible permeabilization of plasma membranes of biological cells and is typically used for tissue ablation or targeted drug/DNA delivery into living cells. In the context of cancer treatment, full recovery from an electroporation-based procedure is frequently dependent on the spatial distribution/homogeneity of the electric field in the tissue; therefore, the structure of electrodes/applicators plays an important role. This review focuses on the analysis of electrodes and in silico models used for electroporation in cancer treatment and gene therapy. We have reviewed various invasive and non-invasive electrodes; analyzed the spatial electric field distribution using finite element method analysis; evaluated parametric compatibility, and the pros and cons of application; and summarized options for improvement. Additionally, this review highlights the importance of tissue bioimpedance for accurate treatment planning using numerical modeling and the effects of pulse frequency on tissue conductivity and relative permittivity values.
Collapse
Affiliation(s)
| | - Gediminas Staigvila
- Faculty of Electronics, Vilnius Gediminas Technical University, Vilnius, Lithuania
| | - Vitalij Novickij
- Faculty of Electronics, Vilnius Gediminas Technical University, Vilnius, Lithuania
- Department of Immunology, State Research Institute Centre of Innovative Medicine, Vilnius, Lithuania
| |
Collapse
|
7
|
Goyal K, Borkholder DA, Day SW. Dependence of Skin-Electrode Contact Impedance on Material and Skin Hydration. SENSORS (BASEL, SWITZERLAND) 2022; 22:8510. [PMID: 36366209 PMCID: PMC9656728 DOI: 10.3390/s22218510] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/07/2022] [Revised: 10/26/2022] [Accepted: 10/28/2022] [Indexed: 06/16/2023]
Abstract
Dry electrodes offer an accessible continuous acquisition of biopotential signals as part of current in-home monitoring systems but often face challenges of high-contact impedance that results in poor signal quality. The performance of dry electrodes could be affected by electrode material and skin hydration. Herein, we investigate these dependencies using a circuit skin-electrode interface model, varying material and hydration in controlled benchtop experiments on a biomimetic skin phantom simulating dry and hydrated skin. Results of the model demonstrate the contribution of the individual components in the circuit to total impedance and assist in understanding the role of electrode material in the mechanistic principle of dry electrodes. Validation was performed by conducting in vivo skin-electrode contact impedance measurements across ten normative human subjects. Further, the impact of the electrode on biopotential signal quality was evaluated by demonstrating an ability to capture clinically relevant electrocardiogram signals by using dry electrodes integrated into a toilet seat cardiovascular monitoring system. Titanium electrodes resulted in better signal quality than stainless steel electrodes. Results suggest that relative permittivity of native oxide of electrode material come into contact with the skin contributes to the interface impedance, and can lead to enhancement in the capacitive coupling of biopotential signals, especially in dry skin individuals.
Collapse
Affiliation(s)
- Krittika Goyal
- Department of Microsystems Engineering, Rochester Institute of Technology, Rochester, NY 14623, USA
| | - David A. Borkholder
- Department of Microsystems Engineering, Rochester Institute of Technology, Rochester, NY 14623, USA
| | - Steven W. Day
- Department of Biomedical Engineering, Rochester Institute of Technology, Rochester, NY 14623, USA
| |
Collapse
|
8
|
Jeon B, Jung HG, Lee SW, Lee G, Shim JH, Kim MO, Kim BJ, Kim SH, Lee H, Lee SW, Yoon DS, Jo SJ, Choi TH, Lee W. Melanoma Detection by AFM Indentation of Histological Specimens. Diagnostics (Basel) 2022; 12:1736. [PMID: 35885640 PMCID: PMC9323377 DOI: 10.3390/diagnostics12071736] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2022] [Revised: 06/29/2022] [Accepted: 07/15/2022] [Indexed: 11/16/2022] Open
Abstract
Melanoma is visible unlike other types of cancer, but it is still challenging to diagnose correctly because of the difficulty in distinguishing between benign nevus and melanoma. We conducted a robust investigation of melanoma, identifying considerable differences in local elastic properties between nevus and melanoma tissues by using atomic force microscopy (AFM) indentation of histological specimens. Specifically, the histograms of the elastic modulus of melanoma displayed multimodal Gaussian distributions, exhibiting heterogeneous mechanical properties, in contrast with the unimodal distributions of elastic modulus in the benign nevus. We identified this notable signature was consistent regardless of blotch incidence by sex, age, anatomical site (e.g., thigh, calf, arm, eyelid, and cheek), or cancer stage (I, IV, and V). In addition, we found that the non-linearity of the force-distance curves for melanoma is increased compared to benign nevus. We believe that AFM indentation of histological specimens may technically complement conventional histopathological analysis for earlier and more precise melanoma detection.
Collapse
Affiliation(s)
- Byoungjun Jeon
- Interdisciplinary Program for Bioengineering, Graduate School, Seoul National University, Seoul 08826, Korea;
| | - Hyo Gi Jung
- School of Biomedical Engineering, Korea University, Seoul 02841, Korea; (H.G.J.); (S.W.L.); (D.S.Y.)
- Interdisciplinary Program in Precision Public Health, Korea University, Seoul 02841, Korea
| | - Sang Won Lee
- School of Biomedical Engineering, Korea University, Seoul 02841, Korea; (H.G.J.); (S.W.L.); (D.S.Y.)
| | - Gyudo Lee
- Department of Biotechnology and Bioinformatics, Korea University, Sejong 30019, Korea;
- Interdisciplinary Graduate Program for Artificial Intelligence Smart Convergence Technology, Korea University, Sejong 30019, Korea
| | - Jung Hee Shim
- Department of Plastic and Reconstructive Surgery, Research Services, Seoul National University Bundang Hospital, Seongnam 13620, Korea;
| | - Mi Ok Kim
- Department of Plastic and Reconstructive Surgery, Institute of Human Environment Interface Biology, Seoul National University College of Medicine, Seoul 03087, Korea; (M.O.K.); (B.J.K.)
| | - Byung Jun Kim
- Department of Plastic and Reconstructive Surgery, Institute of Human Environment Interface Biology, Seoul National University College of Medicine, Seoul 03087, Korea; (M.O.K.); (B.J.K.)
| | - Sang-Hyon Kim
- Department of Internal Medicine, Keimyung University Dongsan Medical Center, Daegu 41931, Korea;
| | - Hyungbeen Lee
- Department of Biomedical Engineering, Yonsei University, Wonju 26493, Korea; (H.L.); (S.W.L.)
- R&D Center of Curigin Ltd., Seoul 04778, Korea
| | - Sang Woo Lee
- Department of Biomedical Engineering, Yonsei University, Wonju 26493, Korea; (H.L.); (S.W.L.)
| | - Dae Sung Yoon
- School of Biomedical Engineering, Korea University, Seoul 02841, Korea; (H.G.J.); (S.W.L.); (D.S.Y.)
- Interdisciplinary Program in Precision Public Health, Korea University, Seoul 02841, Korea
- Astrion Inc., Seoul 02841, Korea
| | - Seong Jin Jo
- Department of Dermatology, Seoul National University College of Medicine, Seoul 03087, Korea
| | - Tae Hyun Choi
- Department of Plastic and Reconstructive Surgery, Institute of Human Environment Interface Biology, Seoul National University College of Medicine, Seoul 03087, Korea; (M.O.K.); (B.J.K.)
| | - Wonseok Lee
- Department of Electrical Engineering, Korea National University of Transportation, Chungju 27469, Korea
| |
Collapse
|
9
|
Arpaia P, Crauso F, Frosolone M, Mariconda M, Minucci S, Moccaldi N. A personalized FEM model for reproducible measurement of anti-inflammatory drugs in transdermal administration to knee. Sci Rep 2022; 12:673. [PMID: 35027630 PMCID: PMC8758660 DOI: 10.1038/s41598-021-04718-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2021] [Accepted: 11/08/2021] [Indexed: 11/09/2022] Open
Abstract
A personalized model of the human knee for enhancing the inter-individual reproducibility of a measurement method for monitoring Non-Steroidal Anti-Inflammatory Drugs (NSAIDs) after transdermal delivery is proposed. The model is based on the solution of Maxwell Equations in the electric-quasi-stationary limit via Finite Element Analysis. The dimensions of the custom geometry are estimated on the basis of knee circumference at the patella, body mass index, and sex of each individual. An optimization algorithm allows to find out the electrical parameters of each subject by experimental impedance spectroscopy data. Muscular tissues were characterized anisotropically, by extracting Cole-Cole equation parameters from experimental data acquired with twofold excitation, both transversal and parallel to tissue fibers. A sensitivity and optimization analysis aiming at reducing computational burden in model customization achieved a worst-case reconstruction error lower than 5%. The personalized knee model and the optimization algorithm were validated in vivo by an experimental campaign on thirty volunteers, 67% healthy and 33% affected by knee osteoarthritis (Kellgren-Lawrence grade ranging in [1,4]), with an average error of 3%.
Collapse
Affiliation(s)
- Pasquale Arpaia
- Laboratory of Augmented Reality for Health Monitoring (ARHeMLab), Department of Electrical Engineering and Information Technology, University of Naples Federico II, Naples, Italy.,Interdepartmental Center for Research in Health Management and Innovation in Health (CIRMIS), University of Naples Federico II, Naples, Italy
| | - Federica Crauso
- Laboratory of Augmented Reality for Health Monitoring (ARHeMLab), Department of Electrical Engineering and Information Technology, University of Naples Federico II, Naples, Italy.,Department of Advanced Biomedical Sciences, University of Naples Federico II, Naples, Italy
| | - Mirco Frosolone
- Laboratory of Augmented Reality for Health Monitoring (ARHeMLab), Department of Electrical Engineering and Information Technology, University of Naples Federico II, Naples, Italy.,Department of Public Health, University of Naples Federico II, Naples, Italy
| | - Massimo Mariconda
- Department of Public Health, University of Naples Federico II, Naples, Italy
| | - Simone Minucci
- Laboratory of Augmented Reality for Health Monitoring (ARHeMLab), Department of Electrical Engineering and Information Technology, University of Naples Federico II, Naples, Italy. .,Department of Economics, Engineering, Society and Business Organization (DEIM), University of Tuscia, Viterbo, Italy.
| | - Nicola Moccaldi
- Laboratory of Augmented Reality for Health Monitoring (ARHeMLab), Department of Electrical Engineering and Information Technology, University of Naples Federico II, Naples, Italy
| |
Collapse
|
10
|
Abe Y, Nishizawa M. Electrical aspects of skin as a pathway to engineering skin devices. APL Bioeng 2021; 5:041509. [PMID: 34849444 PMCID: PMC8604566 DOI: 10.1063/5.0064529] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2021] [Accepted: 09/27/2021] [Indexed: 02/07/2023] Open
Abstract
Skin is one of the indispensable organs for life. The epidermis at the outermost surface provides a permeability barrier to infectious agents, chemicals, and excessive loss of water, while the dermis and subcutaneous tissue mechanically support the structure of the skin and appendages, including hairs and secretory glands. The integrity of the integumentary system is a key for general health, and many techniques have been developed to measure and control this protective function. In contrast, the effective skin barrier is the major obstacle for transdermal delivery and detection. Changes in the electrical properties of skin, such as impedance and ionic activity, is a practical indicator that reflects the structures and functions of the skin. For example, the impedance that reflects the hydration of the skin is measured for quantitative assessment in skincare, and the current generated across a wound is used for the evaluation and control of wound healing. Furthermore, the electrically charged structure of the skin enables transdermal drug delivery and chemical extraction. This paper provides an overview of the electrical aspects of the skin and summarizes current advances in the development of devices based on these features.
Collapse
Affiliation(s)
- Yuina Abe
- Department of Finemechanics, Graduate School of Engineering, Tohoku University, 6-6-01 Aramaki-aza Aoba, Aoba-ku, Sendai 980-8579, Japan
| | - Matsuhiko Nishizawa
- Department of Finemechanics, Graduate School of Engineering, Tohoku University, 6-6-01 Aramaki-aza Aoba, Aoba-ku, Sendai 980-8579, Japan
| |
Collapse
|
11
|
Mitamura Y, Ogulur I, Pat Y, Rinaldi AO, Ardicli O, Cevhertas L, Brüggen MC, Traidl-Hoffmann C, Akdis M, Akdis CA. Dysregulation of the epithelial barrier by environmental and other exogenous factors. Contact Dermatitis 2021; 85:615-626. [PMID: 34420214 PMCID: PMC9293165 DOI: 10.1111/cod.13959] [Citation(s) in RCA: 38] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2021] [Revised: 08/11/2021] [Accepted: 08/18/2021] [Indexed: 12/26/2022]
Abstract
The “epithelial barrier hypothesis” proposes that the exposure to various epithelial barrier–damaging agents linked to industrialization and urbanization underlies the increase in allergic diseases. The epithelial barrier constitutes the first line of physical, chemical, and immunological defense against environmental factors. Recent reports have shown that industrial products disrupt the epithelial barriers. Innate and adaptive immune responses play an important role in epithelial barrier damage. In addition, recent studies suggest that epithelial barrier dysfunction plays an essential role in the pathogenesis of the atopic march by allergen sensitization through the transcutaneous route. It is evident that external factors interact with the immune system, triggering a cascade of complex reactions that damage the epithelial barrier. Epigenetic and microbiome changes modulate the integrity of the epithelial barrier. Robust and simple measurements of the skin barrier dysfunction at the point‐of‐care are of significant value as a biomarker, as recently reported using electrical impedance spectroscopy to directly measure barrier defects. Understanding epithelial barrier dysfunction and its mechanism is key to developing novel strategies for the prevention and treatment of allergic diseases. The aim of this review is to summarize recent studies on the pathophysiological mechanisms triggered by environmental factors that contribute to the dysregulation of epithelial barrier function.
Collapse
Affiliation(s)
- Yasutaka Mitamura
- Swiss Institute of Allergy and Asthma Research (SIAF), University of Zurich, Davos
| | - Ismail Ogulur
- Swiss Institute of Allergy and Asthma Research (SIAF), University of Zurich, Davos.,Division of Pediatric Allergy and Immunology, School of Medicine, Marmara University, Istanbul, Turkey
| | - Yagiz Pat
- Swiss Institute of Allergy and Asthma Research (SIAF), University of Zurich, Davos.,Department of Medical Microbiology, Faculty of Medicine, Aydin Menderes University, Aydin, Turkey
| | - Arturo O Rinaldi
- Swiss Institute of Allergy and Asthma Research (SIAF), University of Zurich, Davos
| | - Ozge Ardicli
- Swiss Institute of Allergy and Asthma Research (SIAF), University of Zurich, Davos.,Department of Microbiology, Faculty of Veterinary Medicine, Bursa Uludag University, Bursa, Turkey
| | - Lacin Cevhertas
- Swiss Institute of Allergy and Asthma Research (SIAF), University of Zurich, Davos.,Department of Medical Immunology, Institute of Health Sciences, Bursa Uludag University, Bursa, Turkey
| | - Marie-Charlotte Brüggen
- Christine Kühne-Center for Allergy Research and Education, Davos.,Department of Dermatology, University Hospital Zurich, Zurich, Switzerland.,Faculty of Medicine, University of Zurich, Zurich, Switzerland
| | - Claudia Traidl-Hoffmann
- Christine Kühne-Center for Allergy Research and Education, Davos.,Department of Environmental Medicine, Faculty of Medicine, University of Augsburg, Augsburg, Germany
| | - Mubeccel Akdis
- Swiss Institute of Allergy and Asthma Research (SIAF), University of Zurich, Davos
| | - Cezmi A Akdis
- Swiss Institute of Allergy and Asthma Research (SIAF), University of Zurich, Davos.,Christine Kühne-Center for Allergy Research and Education, Davos
| |
Collapse
|
12
|
Edwick DO, Hince DA, Rawlins JM, Wood FM, Edgar DW. Alternate Electrode Positions for the Measurement of Hand Volumes Using Bioimpedance Spectroscopy. Lymphat Res Biol 2020; 18:560-571. [DOI: 10.1089/lrb.2019.0078] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023] Open
Affiliation(s)
- Dale O. Edwick
- State Adult Burns Unit, Fiona Stanley Hospital, Murdoch, Australia
- School of Physiotherapy, The University of Notre Dame Australia, Fremantle, Australia
- Fiona Wood Foundation, Fiona Stanley Hospital, Murdoch, Australia
| | - Dana A. Hince
- Institute of Health Research, The University of Notre Dame Australia, Fremantle, Australia
| | - Jeremy M. Rawlins
- State Adult Burns Unit, Fiona Stanley Hospital, Murdoch, Australia
- Department of Plastic and Maxillofacial Surgery, Royal Perth Hospital, Perth, Australia
| | - Fiona M. Wood
- State Adult Burns Unit, Fiona Stanley Hospital, Murdoch, Australia
- Fiona Wood Foundation, Fiona Stanley Hospital, Murdoch, Australia
- Burn Injury Research Unit, The University of Western Australia, Nedlands, Australia
| | - Dale W. Edgar
- State Adult Burns Unit, Fiona Stanley Hospital, Murdoch, Australia
- Fiona Wood Foundation, Fiona Stanley Hospital, Murdoch, Australia
- Institute of Health Research, The University of Notre Dame Australia, Fremantle, Australia
| |
Collapse
|
13
|
Breiteneder H, Peng Y, Agache I, Diamant Z, Eiwegger T, Fokkens WJ, Traidl‐Hoffmann C, Nadeau K, O'Hehir RE, O'Mahony L, Pfaar O, Torres MJ, Wang D, Zhang L, Akdis CA. Biomarkers for diagnosis and prediction of therapy responses in allergic diseases and asthma. Allergy 2020; 75:3039-3068. [PMID: 32893900 PMCID: PMC7756301 DOI: 10.1111/all.14582] [Citation(s) in RCA: 136] [Impact Index Per Article: 27.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2020] [Revised: 08/25/2020] [Accepted: 08/27/2020] [Indexed: 02/06/2023]
Abstract
Modern health care requires a proactive and individualized response to diseases, combining precision diagnosis and personalized treatment. Accordingly, the approach to patients with allergic diseases encompasses novel developments in the area of personalized medicine, disease phenotyping and endotyping, and the development and application of reliable biomarkers. A detailed clinical history and physical examination followed by the detection of IgE immunoreactivity against specific allergens still represents the state of the art. However, nowadays, further emphasis focuses on the optimization of diagnostic and therapeutic standards and a large number of studies have been investigating the biomarkers of allergic diseases, including asthma, atopic dermatitis, allergic rhinitis, food allergy, urticaria and anaphylaxis. Various biomarkers have been developed by omics technologies, some of which lead to a better classification of distinct phenotypes or endotypes. The introduction of biologicals to clinical practice increases the need for biomarkers for patient selection, prediction of outcomes and monitoring, to allow for an adequate choice of the duration of these costly and long‐lasting therapies. Escalating healthcare costs together with questions about the efficacy of the current management of allergic diseases require further development of a biomarker‐driven approach. Here, we review biomarkers in diagnosis and treatment of asthma, atopic dermatitis, allergic rhinitis, viral infections, chronic rhinosinusitis, food allergy, drug hypersensitivity and allergen immunotherapy with a special emphasis on specific IgE, the microbiome and the epithelial barrier. In addition, EAACI guidelines on biologicals are discussed within the perspective of biomarkers.
Collapse
Affiliation(s)
- Heimo Breiteneder
- Institute of Pathophysiology and Allergy Research Medical University of Vienna Vienna Austria
| | - Ya‐Qi Peng
- Swiss Institute of Allergy and Asthma Research (SIAF) University Zurich Davos Switzerland
- CK CARE Christine Kühne Center for Allergy Research and Education Davos Switzerland
- Otorhinolaryngology Hospital The First Affiliated Hospital Sun Yat‐Sen University Guangzhou China
| | - Ioana Agache
- Department of Allergy and Clinical Immunology Faculty of Medicine Transylvania University of Brasov Brasov Romania
| | - Zuzana Diamant
- Department of Respiratory Medicine & Allergology Institute for Clinical Science Skane University Hospital Lund University Lund Sweden
- Department of Respiratory Medicine First Faculty of Medicine Charles University and Thomayer Hospital Prague Czech Republic
- Department of Clinical Pharmacy & Pharmacology University of GroningenUniversity Medical Center Groningen Groningen Netherlands
| | - Thomas Eiwegger
- Translational Medicine Program, Research Institute Hospital for Sick Children Toronto ON Canada
- Department of Immunology University of Toronto Toronto ON Canada
- Division of Immunology and Allergy Food Allergy and Anaphylaxis Program The Hospital for Sick Children Departments of Paediatrics and Immunology University of Toronto Toronto ON Canada
| | - Wytske J. Fokkens
- Department of Otorhinolaryngology Amsterdam University Medical Centres Amsterdam The Netherlands
| | - Claudia Traidl‐Hoffmann
- CK CARE Christine Kühne Center for Allergy Research and Education Davos Switzerland
- Chair and Institute of Environmental Medicine UNIKA‐T Technical University of Munich and Helmholtz Zentrum München Augsburg Germany
- ZIEL ‐ Institute for Food & Health Technical University of Munich Freising‐Weihenstephan Germany
| | - Kari Nadeau
- Sean N. Parker Center for Allergy & Asthma Research Stanford University Stanford CA USA
| | - Robyn E. O'Hehir
- Department of Allergy, immunology and Respiratory Medicine Central Clinical School Monash University Melbourne Vic. Australia
- Allergy, Asthma and Clinical Immunology Service Alfred Health Melbourne Vic. Australia
| | - Liam O'Mahony
- Departments of Medicine and Microbiology APC Microbiome Ireland National University of Ireland Cork Ireland
| | - Oliver Pfaar
- Department of Otorhinolaryngology, Head and Neck Surgery Section of Rhinology and Allergy University Hospital MarburgPhilipps‐Universität Marburg Marburg Germany
| | - Maria J. Torres
- Allergy Unit Regional University Hospital of Malaga‐IBIMA‐UMA‐ARADyAL Malaga Spain
| | - De‐Yun Wang
- Department of Otolaryngology Yong Loo Lin School of Medicine National University of Singapore Singapore Singapore
| | - Luo Zhang
- Department of Otolaryngology Head and Neck Surgery and Department of Allergy Beijing TongRen Hospital Beijing China
| | - Cezmi A. Akdis
- Swiss Institute of Allergy and Asthma Research (SIAF) University Zurich Davos Switzerland
- CK CARE Christine Kühne Center for Allergy Research and Education Davos Switzerland
| |
Collapse
|
14
|
Sugita K, Soyka MB, Wawrzyniak P, Rinaldi AO, Mitamura Y, Akdis M, Akdis CA. Outside-in hypothesis revisited: The role of microbial, epithelial, and immune interactions. Ann Allergy Asthma Immunol 2020; 125:517-527. [PMID: 32454094 DOI: 10.1016/j.anai.2020.05.016] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2020] [Revised: 05/14/2020] [Accepted: 05/17/2020] [Indexed: 02/06/2023]
Abstract
OBJECTIVE Our understanding of the origin of allergic diseases has increased in recent years, highlighting the importance of microbial dysbiosis and epithelial barrier dysfunction in affected tissues. Exploring the microbial-epithelial-immune crosstalk underlying the mechanisms of allergic diseases will allow the development of novel prevention and treatment strategies for allergic diseases. DATA SOURCES This review summarizes the recent advances in microbial, epithelial, and immune interactions in atopic dermatitis, allergic rhinitis, chronic rhinosinusitis, and asthma. STUDY SELECTIONS We performed a literature search, identifying relevant recent primary articles and review articles. RESULTS Dynamic crosstalk between the environmental factors and microbial, epithelial, and immune cells in the development of atopic dermatitis, allergic rhinitis, chronic rhinosinusitis, and asthma underlies the pathogenesis of these diseases. There is substantial evidence in the literature suggesting that environmental factors directly affect barrier function of the epithelium. In addition, T-helper 2 (TH2) cells, type 2 innate lymphoid cells, and their cytokine interleukin 13 (IL-13) damage skin and lung barriers. The effects of environmental factors may at least in part be mediated by epigenetic mechanisms. Histone deacetylase activation by type 2 immune response has a major effect on leaky barriers and blocking of histone deacetylase activity corrects the defective barrier in human air-liquid interface cultures and mouse models of allergic asthma with rhinitis. We also present and discuss a novel device to detect and monitor skin barrier dysfunction, which provides an opportunity to rapidly and robustly assess disease severity. CONCLUSION A complex interplay between environmental factors, epithelium, and the immune system is involved in the development of systemic allergic diseases.
Collapse
Affiliation(s)
- Kazunari Sugita
- Swiss Institute of Allergy and Asthma Research (SIAF), University of Zurich, Davos, Switzerland; Christine Kühne-Center for Allergy Research and Education, Davos, Switzerland; Division of Dermatology, Department of Medicine of Sensory and Motor Organs, Faculty of Medicine, Tottori University, Yonago, Japan.
| | - Michael B Soyka
- Swiss Institute of Allergy and Asthma Research (SIAF), University of Zurich, Davos, Switzerland; Department of Otorhinolaryngology, Head and Neck Surgery, University and University Hospital of Zurich, Zurich, Switzerland
| | - Paulina Wawrzyniak
- Division of Clinical Chemistry and Biochemistry and Children's Research Center, University Children's Hospital Zurich, Zurich, Switzerland
| | - Arturo O Rinaldi
- Swiss Institute of Allergy and Asthma Research (SIAF), University of Zurich, Davos, Switzerland
| | - Yasutaka Mitamura
- Swiss Institute of Allergy and Asthma Research (SIAF), University of Zurich, Davos, Switzerland; Christine Kühne-Center for Allergy Research and Education, Davos, Switzerland
| | - Mübeccel Akdis
- Swiss Institute of Allergy and Asthma Research (SIAF), University of Zurich, Davos, Switzerland
| | - Cezmi A Akdis
- Swiss Institute of Allergy and Asthma Research (SIAF), University of Zurich, Davos, Switzerland; Christine Kühne-Center for Allergy Research and Education, Davos, Switzerland
| |
Collapse
|
15
|
Rinaldi AO, Morita H, Wawrzyniak P, Dreher A, Grant S, Svedenhag P, Akdis CA. Direct assessment of skin epithelial barrier by electrical impedance spectroscopy. Allergy 2019; 74:1934-1944. [PMID: 30989659 DOI: 10.1111/all.13824] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2018] [Revised: 03/12/2019] [Accepted: 03/26/2019] [Indexed: 12/14/2022]
Abstract
BACKGROUND Many skin and mucosal inflammatory disorders, such as atopic dermatitis, have been associated with an impaired epithelial barrier function, which allows allergens, pollutants, or microbes to enter the tissue and activate the immune response. The aim of this study was to establish a method to directly assess in vivo the epidermal barrier function by electrical impedance (EI) spectroscopy. METHODS Mice epidermal barrier was damaged by epicutaneous application of proteases and cholera toxin and by tape stripping. EI and transepidermal water loss (TEWL) were measured before and after the application. Additionally, histological analysis, immunofluorescence staining, and RT-PCR were performed on skin biopsies to evaluate the epithelial barrier. RESULTS A few hours after papain application, a dose-dependent reduction of EI was detected, reflecting the decreased barrier function. At the same time, an increase of TEWL was observed, with a significant negative correlation with EI, demonstrating that EI changes were directly linked to barrier defects. Twenty-four and 48 hours after the treatment, EI starts to increase to background levels, indicating tissue healing and restoration of skin barrier. Barrier disruption was confirmed by histological analysis showing an impaired stratum corneum and higher cellular infiltration after papain application. In addition, immunofluorescence staining and RT-PCR showed downregulation of molecules involved in the barrier function, such as filaggrin, occludin, and claudin-1, and mRNA levels of filaggrin, loricrin, and involucrin. Comparable results were observed after tape stripping and cholera toxin treatment. CONCLUSION Electrical impedance spectroscopy is a rapid and reliable diagnostic tool to detect skin barrier defects.
Collapse
Affiliation(s)
- Arturo O. Rinaldi
- Swiss Institute of Allergy and Asthma Research (SIAF) Davos Switzerland
- Christine Kühne – Center for Allergy Research and Education (CK‐CARE) Davos Switzerland
| | - Hideaki Morita
- Swiss Institute of Allergy and Asthma Research (SIAF) Davos Switzerland
- Christine Kühne – Center for Allergy Research and Education (CK‐CARE) Davos Switzerland
| | - Paulina Wawrzyniak
- Swiss Institute of Allergy and Asthma Research (SIAF) Davos Switzerland
- Christine Kühne – Center for Allergy Research and Education (CK‐CARE) Davos Switzerland
| | - Anita Dreher
- Swiss Institute of Allergy and Asthma Research (SIAF) Davos Switzerland
- Christine Kühne – Center for Allergy Research and Education (CK‐CARE) Davos Switzerland
| | | | | | - Cezmi A. Akdis
- Swiss Institute of Allergy and Asthma Research (SIAF) Davos Switzerland
- Christine Kühne – Center for Allergy Research and Education (CK‐CARE) Davos Switzerland
| |
Collapse
|
16
|
Measurement and analysis of partial lightning currents in a head phantom. PLoS One 2019; 14:e0223133. [PMID: 31557252 PMCID: PMC6762108 DOI: 10.1371/journal.pone.0223133] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2019] [Accepted: 09/14/2019] [Indexed: 11/19/2022] Open
Abstract
Direct lightning strikes to the human head can lead to various effects, ranging from burnings to death. The biological and physical mechanisms of a direct lightning strike in the human head are not well understood. The aim of this paper is to design an experimental setup to measure the spatial and temporal current distribution during a direct lightning strike to physical head phantoms to establish normative values for personal lightning protection equipment design and testing. We created head phantoms made of agarose, replicating the geometric and dielectric properties of scalp, skull, and intracranial volume. The bases of the three compartments were galvanically contacted via copper electrodes to measure the current per compartment. We used pulse generators to apply aperiodic voltage and current signals that modelled lightning components. Our experiments indicated that the scalp compartment was exposed to the current with a fraction of 80–90%. The brain and skull compartments were exposed between 6–13% and 3–6% of the total measured current respectively. In case of a flashover, most of the current (98–99%) flowed through the discharge channel. Unlike previous theoretical estimates and measurements in technical setups, we observed considerably longer times for the flashover to build up. In our experiments, the time to build up a fully formed flashover varied from approximately 30–700 μs. The observed current patterns in cases without and with flashover provided information on regions of possible damage in the human head. Consequently, we identified the phenomenon of a flashover as a potential mechanism for humans to survive a lightning strike. Our measured current distributions and amplitudes formed the base for normative values, which can be used in later experimental investigations regarding the possibilities of individual lightning protection equipment for humans.
Collapse
|
17
|
Tsai B, Xue H, Birgersson E, Ollmar S, Birgersson U. Dielectrical Properties of Living Epidermis and Dermis in the Frequency Range from 1 kHz to 1 MHz. JOURNAL OF ELECTRICAL BIOIMPEDANCE 2019; 10:14-23. [PMID: 33584878 PMCID: PMC7531215 DOI: 10.2478/joeb-2019-0003] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/28/2018] [Indexed: 06/01/2023]
Abstract
We determine the in-vivo dielectric properties-resistivity and relative permittivity-of living epidermis and dermis of human skin soaked with a physiological saline solution for one minute between 1 kHz and 1 MHz. This is done by fitting approximate analytical solutions of a mechanistic model for the transport of charges in these layers to a training set comprising impedance measurements at two depth settings on stripped skin on the volar forearm of 24 young subjects. Here, the depth settings are obtained by varying the voltage at a second inject on the electrical-impedance-spectroscopy probe. The model and the dielectric properties are validated with a test set for a third depth setting with overall good agreement. In addition, the means and standard deviations of the thicknesses of living epidermis and dermis are estimated from a literature review as 61±7 μm and 1.0±0.2 mm respectively. Furthermore, extensions to resolve the skin layers in more detail are suggested.
Collapse
Affiliation(s)
- B. Tsai
- Department of Chemical and Biomolecular Engineering, National University of Singapore, 4 Engineering Drive 4, Singapore, Singapore117585
| | - H. Xue
- Department of Chemical and Biomolecular Engineering, National University of Singapore, 4 Engineering Drive 4, Singapore, Singapore117585
| | - E. Birgersson
- Department of Mechanical Engineering, National University of Singapore, 5 Engineering Drive 2, Singapore, Singapore117576
| | - S. Ollmar
- Department of Clinical Science, Intervention and Technology, Karolinska Institutet, SE-14186StockholmSweden
| | - U. Birgersson
- Department of Clinical Science, Intervention and Technology, Karolinska Institutet, SE-14186StockholmSweden
| |
Collapse
|
18
|
Addressing the Barriers to Bioimpedance Spectroscopy Use in Major Burns: Alternate Electrode Placement. J Burn Care Res 2018; 38:e952-e959. [PMID: 28328660 DOI: 10.1097/bcr.0000000000000527] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
Bioimpedance spectroscopy (BIS) is a method used to assess body composition and fluid distribution. As a technology for measurement of fluid shifts during acute burn resuscitation, there are potential barriers to its use due to the location of wounds. This study aimed to determine whether alternate electrode positions were a suitable alternative compared to standardized (manufacturer) positions in moderate to large size burns for the measurement of BIS resistance and fluid changes. BIS measurements were collected in standard and alternate electrode placements and in an open wound and Acticoat™ dressing condition. A percentage difference greater than 5% between each standard and alternate placement BIS measurements was deemed clinically significant. Chi-square tests determined there were no significant differences (P = .097-.96) between the standard and alternate electrode placements for whole body and limb segment BIS in both dressing conditions. Only whole body BIS resistance variables and extracellular fluid volumes were interchangeable in both dressing conditions and upper limb segmental measures were interchangeable in an open wound only. The differences between measurements of other BIS variables across the conditions were not acceptable or deemed not clinically acceptable without adjustment. The results showed that for moderate to large burn injuries clinicians can use whole body and upper limb segmental BIS variables to monitor changes in fluid shifts with alternate electrode placements where wounds preclude standardized placement within specified dressing conditions.
Collapse
|
19
|
Forschner A, Keim U, Hofmann M, Spänkuch I, Lomberg D, Weide B, Tampouri I, Eigentler T, Fink C, Garbe C, Haenssle HA. Diagnostic accuracy of dermatofluoroscopy in cutaneous melanoma detection: results of a prospective multicentre clinical study in 476 pigmented lesions. Br J Dermatol 2018; 179:478-485. [PMID: 29569229 DOI: 10.1111/bjd.16565] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/11/2018] [Indexed: 01/13/2023]
Abstract
BACKGROUND Early detection is a key factor in improving survival from melanoma. Today, the clinical diagnosis of cutaneous melanoma is based mostly on visual inspection and dermoscopy. Preclinical studies in freshly excised or paraffin-embedded tissue have shown that the melanin fluorescence spectra after stepwise two-photon excitation, a process termed dermatofluoroscopy, differ between cutaneous melanoma and melanocytic naevi. However, confirmation from a larger prospective clinical study is lacking. OBJECTIVES The primary end point of this study was to determine the diagnostic accuracy of dermatofluoroscopy in melanoma detection. Secondary end points included the collection of data for improving the computer algorithm that classifies skin lesions based on melanin fluorescence and the assessment of safety aspects. METHODS This was a prospective, blinded, multicentre clinical study in patients with pigmented skin lesions (PSLs) indicated for excision either to rule out or to confirm cutaneous melanoma. All included lesions underwent dermoscopy and dermatofluoroscopy in vivo before lesions were excised and subjected to histopathological examination. RESULTS In total, 369 patients and 476 PSLs were included in the final analysis. In 101 of 476 lesions (21·2%) histopathology revealed melanoma. The observed sensitivity of dermatofluoroscopy was 89·1% (90 of 101 melanomas identified), with an observed specificity of 44·8%. The positive and negative predictive values were 30·3% and 93·9%, respectively. No adverse events occurred. CONCLUSIONS Dermatofluoroscopy is a safe and accurate diagnostic method to aid physicians in diagnosing cutaneous melanoma. Limitations arise from largely amelanotic or regressing lesions lacking sufficient melanin fluorescence.
Collapse
Affiliation(s)
- A Forschner
- Centre of Dermatooncology, Department of Dermatology, Eberhard-Karls-University, Tübingen, Germany
| | - U Keim
- Centre of Dermatooncology, Department of Dermatology, Eberhard-Karls-University, Tübingen, Germany
| | - M Hofmann
- University Department of Dermatology, Charité Universitätsmedizin Berlin, Berlin, Germany
| | - I Spänkuch
- Centre of Dermatooncology, Department of Dermatology, Eberhard-Karls-University, Tübingen, Germany
| | - D Lomberg
- Centre of Dermatooncology, Department of Dermatology, Eberhard-Karls-University, Tübingen, Germany
| | - B Weide
- Centre of Dermatooncology, Department of Dermatology, Eberhard-Karls-University, Tübingen, Germany
| | - I Tampouri
- Centre of Dermatooncology, Department of Dermatology, Eberhard-Karls-University, Tübingen, Germany
| | - T Eigentler
- Centre of Dermatooncology, Department of Dermatology, Eberhard-Karls-University, Tübingen, Germany
| | - C Fink
- Department of Dermatology, University of Heidelberg, Im Neuenheimer Feld 440,, 69120, Heidelberg, Germany
| | - C Garbe
- Centre of Dermatooncology, Department of Dermatology, Eberhard-Karls-University, Tübingen, Germany
| | - H A Haenssle
- Department of Dermatology, University of Heidelberg, Im Neuenheimer Feld 440,, 69120, Heidelberg, Germany
| |
Collapse
|
20
|
Lu F, Wang C, Zhao R, Du L, Fang Z, Guo X, Zhao Z. Review of Stratum Corneum Impedance Measurement in Non-Invasive Penetration Application. BIOSENSORS 2018; 8:E31. [PMID: 29587456 PMCID: PMC6023082 DOI: 10.3390/bios8020031] [Citation(s) in RCA: 51] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/24/2018] [Revised: 03/10/2018] [Accepted: 03/12/2018] [Indexed: 11/19/2022]
Abstract
Due to advances in telemedicine, mobile medical care, wearable health monitoring, and electronic skin, great efforts have been directed to non-invasive monitoring and treatment of disease. These processes generally involve disease detection from interstitial fluid (ISF) instead of blood, and transdermal drug delivery. However, the quantitative extraction of ISF and the level of drug absorption are greatly affected by the individual's skin permeability, which is closely related to the properties of the stratum corneum (SC). Therefore, measurement of SC impedance has been proposed as an appropriate way for assessing individual skin differences. In order to figure out the current status and research direction of human SC impedance detection, investigations regarding skin impedance measurement have been reviewed in this paper. Future directions are concluded after a review of impedance models, electrodes, measurement methods and systems, and their applications in treatment. It is believed that a well-matched skin impedance model and measurement method will be established for clinical and point-of care applications in the near future.
Collapse
Affiliation(s)
- Fei Lu
- State Key Laboratory of Transducer Technology, Institute of Electronics, Chinese Academy of Sciences, Beijing 100190, China.
- University of Chinese Academy of Sciences, Beijing 100049, China.
| | - Chenshuo Wang
- State Key Laboratory of Transducer Technology, Institute of Electronics, Chinese Academy of Sciences, Beijing 100190, China.
- University of Chinese Academy of Sciences, Beijing 100049, China.
| | - Rongjian Zhao
- State Key Laboratory of Transducer Technology, Institute of Electronics, Chinese Academy of Sciences, Beijing 100190, China.
- University of Chinese Academy of Sciences, Beijing 100049, China.
| | - Lidong Du
- State Key Laboratory of Transducer Technology, Institute of Electronics, Chinese Academy of Sciences, Beijing 100190, China.
| | - Zhen Fang
- State Key Laboratory of Transducer Technology, Institute of Electronics, Chinese Academy of Sciences, Beijing 100190, China.
- University of Chinese Academy of Sciences, Beijing 100049, China.
| | - Xiuhua Guo
- School of Public Health, Capital Medical University, Beijing 100069, China.
- Beijing Municipal Key Laboratory of Clinical Epidemiology, Beijing 100069, China.
| | - Zhan Zhao
- State Key Laboratory of Transducer Technology, Institute of Electronics, Chinese Academy of Sciences, Beijing 100190, China.
- University of Chinese Academy of Sciences, Beijing 100049, China.
| |
Collapse
|
21
|
Tsai B, Birgersson E, Birgersson U. Mechanistic Multilayer Model for Non-invasive Bioimpedance of Intact Skin. JOURNAL OF ELECTRICAL BIOIMPEDANCE 2018; 9:31-38. [PMID: 33584918 PMCID: PMC7852014 DOI: 10.2478/joeb-2018-0006] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/19/2018] [Indexed: 06/02/2023]
Abstract
An approximate semi-analytical solution based on a Hankel transform of a mechanistic model for electrical impedance spectroscopy (EIS) is derived for a non-invasive axisymmetric concentric probe with m electrodes measuring the response of n layers of human skin. We validate the semi-analytical solution for the case when the skin is treated as a three-layer entity - (i) stratum corneum, (ii) viable skin comprising living epidermis and dermis and (iii) adipose tissue - on the volar forearm in the frequency range 1 kHz to 1 MHz with experimental EIS measurements of 120 young subjects. Overall, we find good agreement for both the mean magnitude and phase of the impedance as well as the natural variability between subjects. Finally, the semi-analytical solution is verified with the full set of equations solved numerically: Good agreement is found for the point-wise potential distribution in the three skin layers.
Collapse
Affiliation(s)
- B. Tsai
- Department of Chemical and Biomolecular Engineering, National University of Singapore, 4 Engineering Drive 4, Singapore, Singapore, 117585
| | - E. Birgersson
- Department of Mechanical Engineering, National University of Singapore, 5 Engineering Drive 2, Singapore, Singapore, 117576
| | - U. Birgersson
- Department of Clinical Science, Intervention and Technology, Karolinska Institutet, SE-14186, Stockholm, Sweden
| |
Collapse
|
22
|
Kekonen A, Bergelin M, Eriksson JE, Vaalasti A, Ylänen H, Viik J. Bioimpedance measurement based evaluation of wound healing. Physiol Meas 2017; 38:1373-1383. [PMID: 28248191 DOI: 10.1088/1361-6579/aa63d6] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVE Our group has developed a bipolar bioimpedance measurement-based method for determining the state of wound healing. The objective of this study was to assess the capability of the method. METHODS To assess the performance of the method, we arranged a follow-up study of four acute wounds. The wounds were measured using the method and photographed throughout the healing process. RESULTS Initially the bioimpedance of the wounds was significantly lower than the impedance of the undamaged skin, used as a baseline. Gradually, as healing progressed, the wound impedance increased and finally reached the impedance of the undamaged skin. CONCLUSION The clinical appearance of the wounds examined in this study corresponded well with the parameters derived from the bioimpedance data. SIGNIFICANCE Hard-to-heal wounds are a significant and growing socioeconomic burden, especially in the developed countries, due to aging populations and to the increasing prevalence of various lifestyle related diseases. The assessment and the monitoring of chronic wounds are mainly based on visual inspection by medical professionals. The dressings covering the wound must be removed before assessment; this may disturb the wound healing process and significantly increases the work effort of the medical staff. There is a need for an objective and quantitative method for determining the status of a wound without removing the wound dressings. This study provided evidence of the capability of the bioimpedance based method for assessing the wound status. In the future measurements with the method should be extended to concern hard-to-heal wounds.
Collapse
Affiliation(s)
- Atte Kekonen
- Faculty of Biomedical Sciences and Engineering, Tampere University of Technology, Tampere, Finland. BioMediTech Institute, Tampere University of Technology, Tampere, Finland
| | | | | | | | | | | |
Collapse
|
23
|
Noninvasive measurement of transdermal drug delivery by impedance spectroscopy. Sci Rep 2017; 7:44647. [PMID: 28338008 PMCID: PMC5364508 DOI: 10.1038/srep44647] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2016] [Accepted: 02/06/2017] [Indexed: 11/09/2022] Open
Abstract
The effectiveness in transdermal delivery of skin permeation strategies (e.g., chemical enhancers, vesicular carrier systems, sonophoresis, iontophoresis, and electroporation) is poorly investigated outside of laboratory. In therapeutic application, the lack of recognized techniques for measuring the actually-released drug affects the scientific concept itself of dosage for topically- and transdermally-delivered drugs. Here we prove the suitability of impedance measurement for assessing the amount of drug penetrated into the skin after transdermal delivery. In particular, the measured amount of drug depends linearly on the impedance magnitude variation normalized to the pre-treated value. Three experimental campaigns, based on the electrical analysis of the biological tissue behavior due to the drug delivery, are reported: (i) laboratory emulation on eggplants, (ii) ex-vivo tests on pig ears, and finally (iii) in-vivo tests on human volunteers. Results point out that the amount of delivered drug can be assessed by reasonable metrological performance through a unique measurement of the impedance magnitude at one single frequency. In particular, in-vivo results point out sensitivity of 23 ml−1, repeatability of 0.3%, non-linearity of 3.3%, and accuracy of 5.7%. Finally, the measurement resolution of 0.20 ml is compatible with clinical administration standards.
Collapse
|
24
|
Abstract
The diagnosis of advanced cutaneous melanoma may easily be made by the unaided eye, followed by excisional biopsy and histopathological examination. However, in the setting of melanoma screening examinations in high-risk patients with many nevi, dermatologists are challenged with the differentiation of atypical but benign nevi and early invasive or in situ melanomas. In this situation, there is a real need for additional, noninvasive examination techniques that may serve as an aide to decide for or against an excisional biopsy. Conventional dermoscopy is a well-established examination procedure and an increase in sensitivity was confirmed by two independent meta-analyses. Moreover, dynamic changes or newly developed pigmented lesions may be detected by sequential digital dermoscopy or (automated) total body photography, respectively. Over the past years, a number of medicinal products gained market access after licensing by American and European agencies for the noninvasive diagnosis of cutaneous neoplasms. These devices are based on technologies including in vivo reflectance confocal microscopy, multispectral analysis, electrical impedance spectroscopy, or Raman spectroscopy. Other technologies are still on the verge of becoming less experimental but more clinically applicable for diagnosing melanoma (in vivo multiphoton tomography, stepwise two-photon laser spectroscopy, infrared thermal image analysis, epidermal genetic information retrieval). This review provides a concise overview of general principles and sheds light on indication and added value for dermatologists.
Collapse
|
25
|
De Guzman K, Morrin A. Screen-printed Tattoo Sensor towards the Non-invasive Assessment of the Skin Barrier. ELECTROANAL 2016. [DOI: 10.1002/elan.201600572] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Affiliation(s)
- Keana De Guzman
- School of Chemical Sciences; National Centre for Sensor Research; Insight Centre for Data Analytics; Dublin City University; Dublin 9 Ireland
| | - Aoife Morrin
- School of Chemical Sciences; National Centre for Sensor Research; Insight Centre for Data Analytics; Dublin City University; Dublin 9 Ireland
| |
Collapse
|
26
|
Machts R, Hunold A, Leu C, Haueisen J, Rock M. Development of a head-phantom and measurement setup for lightning effects. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2016; 2016:3590-3593. [PMID: 28269072 DOI: 10.1109/embc.2016.7591504] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Direct lightning strikes to human heads lead to various effects ranging from Lichtenberg figures, over loss of consciousness to death. The evolution of the induced current distribution in the head is of great interest to understand the effect mechanisms. This work describes a technique to model a simplified head-phantom to investigate effects during direct lightning strike. The head-phantom geometry, conductive and dielectric parameters were chosen similar to that of a human head. Three layers (brain, skull, and scalp) were created for the phantom using agarose hydrogel doped with sodium chloride and carbon. The head-phantom was tested on two different impulse generators, which reproduce approximate lightning impulses. The effective current and the current distribution in each layer were analyzed. The biggest part of the current flowed through the brain layer, approx. 70 % in cases without external flashover. Approx. 23 % of the current flowed through skull layer and 6 % through the scalp layer. However, the current decreased within the head-phantom to almost zero after a complete flashover on the phantom occurred. The flashover formed faster with a higher impulse current level. Exposition time of current through the head decreases with a higher current level of the lightning impulse. This mechanism might explain the fact that people can survive a lightning strike. The experiments help to understand lightning effects on humans.
Collapse
|
27
|
Naydenova E, Cavendish S, Wilson AJ. Measurement and modelling the sensitivity of tetrapolar transfer impedance measurements. Med Eng Phys 2016; 38:1090-9. [PMID: 27475783 DOI: 10.1016/j.medengphy.2016.07.005] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2015] [Revised: 06/06/2016] [Accepted: 07/07/2016] [Indexed: 10/21/2022]
Abstract
Finite element method (FEM) modelling of a small disk in a homogeneous saline medium showed that the sensitivity distribution for tetrapolar transfer impedance measurements was dependant on the ratio, σdisk/σsaline, and not absolute conductivity values. In addition, the amplitude of the negative sensitivity regions between the drive and receive electrodes decreased non-linearly with σdisk/σsaline for σdisk/σsaline < 1, eventually becoming zero. This non-linear behaviour determined the limit of the assumption of a small change in conductivity in Geselowitz's lead theorem with 0.5 <σdisk/σsaline <1.5 for the measurements reported. The modelling supported the design of a sensitivity measurement system using an insulating support and a metal disk in a saline filled tank. Measurements were shown to give good agreement with sensitivity predictions from Geselowitz's lead theorem. Replacing the homogeneous medium in the FEM model with layers of different conductivity parallel to the plane of the electrodes changed the sensitivity distribution when the thickness of the layers adjacent to the electrodes were less than ½ the electrode spacing. A layer of greater conductivity over a layer of lesser conductivity next to the electrodes gave a peak in the sensitivity distribution and extended regions of negative sensitivity further into the tissue.
Collapse
Affiliation(s)
- E Naydenova
- Department of Physics, University of Warwick, Gibbet Hill Road, Coventry CV4 7AL, UK
| | - S Cavendish
- Department of Physics, University of Warwick, Gibbet Hill Road, Coventry CV4 7AL, UK
| | - A J Wilson
- Department of Physics, University of Warwick, Gibbet Hill Road, Coventry CV4 7AL, UK; Department of Clinical Physics and Bioengineering, University Hospital, Coventry CV2 2DX, UK .
| |
Collapse
|
28
|
Grisbrook TL, Kenworthy P, Phillips M, Gittings PM, Wood FM, Edgar DW. Alternate electrode placement for whole body and segmental bioimpedance spectroscopy. Physiol Meas 2015; 36:2189-201. [PMID: 26365564 DOI: 10.1088/0967-3334/36/10/2189] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
Bioimpedance spectroscopy (BIS) is frequently used to monitor body fluid and body composition in healthy and clinical populations. BIS guidelines state that there should be no skin lesions at the site of electrodes, and if lesions are present, electrode positions should be changed. However, alternate electrode positions are yet to be reported. This study aimed to determine if ventral electrode placements were suitable alternatives for whole body and segmental BIS measurements. Three alternate electrode placements were assessed for whole body BIS using a combination of ventral hand and foot electrode placements. An alternate position was assessed for upper and lower body segmental BIS. The results demonstrated that for whole body BIS, if drive and sense electrodes on the hand are moved to ventral positions, but foot electrodes remain in standard positions, then whole body BIS variables were comparable to standard electrode positioning (percentage difference range = 0.01 to 1.65%, p = 0.211-0.937). The alternate electrode placement for upper limb segmental BIS, results in BIS variables that are comparable to that of the standard positioning (percentage difference range = 0.24-3.51%, p = 0.393-0.604). The alternate lower limb electrode position significantly altered all resistance and predicted BIS variables for whole body and lower limb segmental BIS (percentage difference range = 1.06-12.09%, p < 0.001). If wounds are present on the hands and/or wrist, then the alternate electrode position described in this study is valid, for whole body and upper limb segmental BIS.
Collapse
Affiliation(s)
- T L Grisbrook
- Fiona Wood Foundation, Fiona Stanley Hospital, Murdoch, Western Australia, Australia. School of Physiotherapy and Exercise Science, Curtin University, Bentley, Western Australia, Australia
| | | | | | | | | | | |
Collapse
|
29
|
Podtaev S, Nikolaev D, Samartsev V, Gavrilov V, Tsiberkin K. Frequency and temperature dependence of skin bioimpedance during a contralateral cold test. Physiol Meas 2015; 36:561-77. [PMID: 25690397 DOI: 10.1088/0967-3334/36/3/561] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
A study of the α- and β-dispersion of skin bioimpedance dependence on temperature and micro-hemodynamics is presented. The vascular tone changes during the cold test are verified by the wavelet-analysis of skin temperature signals obtained simultaneously with impedance measurements. Thirty three normal healthy subjects of 28 ± 7 years old were entered into the study. The tetra-polar electrode system was used to record the resistance and reactance; measurements were carried out at 67 frequencies, in a frequency range from 2 Hz to 50 kHz. It has been found that the impedance decreases with vasodilation and increases with vasoconstriction. The high values of correlation among thermal oscillation amplitudes and Nyquist diagram parameters prove the impedance dependence on blood flow in three frequency bands corresponding to the myogenic, neurogenic and endothelial vascular tone regulation mechanisms. Using an equivalent RC circuit, we obtained the changes in the Nyquist diagram matching the experimental data. The proposed descriptive α-dispersion model can be used to study mechanisms responsible for intercellular interaction.
Collapse
Affiliation(s)
- S Podtaev
- Institute of Continuous Media Mechanics, Korolyov str.1, Perm 614013, Russia
| | | | | | | | | |
Collapse
|
30
|
Groeber F, Engelhardt L, Egger S, Werthmann H, Monaghan M, Walles H, Hansmann J. Impedance spectroscopy for the non-destructive evaluation of in vitro epidermal models. Pharm Res 2014; 32:1845-54. [PMID: 25467957 PMCID: PMC4381093 DOI: 10.1007/s11095-014-1580-3] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2014] [Accepted: 11/14/2014] [Indexed: 01/08/2023]
Abstract
Purpose Reconstructed human epidermis (RHE) is standardly used for the risk assessment of chemical compounds. However, analysis is dependent on invasive methods such as histological processing or 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) staining. Methods As an alternative, we have developed a non-destructive technology to analyze the integrity of epidermal equivalents based on impedance spectroscopy. RHEs were generated and impedance spectra were recorded. from these spectra, we extrapolated electrical characteristics such as the capacitance and the ohmic resistance. Furthermore, the measurable electrical parameters were used to quantify the effects of mechanical and chemical disruption of the epidermal integrity. Results A fully matured RHE exhibits typical impedance spectra in a frequency ranging between 1 Hz and 100 kHz, which is comparable to the spectra of freshly isolated human epidermal biopsies. We could show that, during RHE maturation, these characteristics change significantly. Thus, capacitance and ohmic resistance can be employed as a criterion for the quality control of skin equivalents. Additionally, our application of impedance spectroscopy reveals sufficient sensitivity to detect a transient decreased ohmic resistance caused by 2-propanol, which is classified as a non-irritant by MTT assays. Conclusion These results indicate that impedance spectroscopy can be employed as a non-destructive complementary method to assess mild irritative effects, which is currently not possible.
Collapse
Affiliation(s)
- F Groeber
- Project Group Regenerative Technologies in Oncology, Fraunhofer Institute for Interfacial Engineering and Biotechnology (IGB), Roentgenring 11, Wuerzburg, 97070, Germany
| | | | | | | | | | | | | |
Collapse
|
31
|
Sung B, Kim SH, Lee JK, Lee BC, Soh KS. Electromechanical method coupling non-invasive skin impedance probing and in vivo subcutaneous liquid microinjection: controlling the diffusion pattern of nanoparticles within living soft tissues. Biomed Microdevices 2014; 16:645-53. [PMID: 24781885 DOI: 10.1007/s10544-014-9867-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
Transdermal drug delivery is the way to transport drug carriers, such as nanoparticles, across the skin barrier to the dermal and/or subcutaneous layer. In order to control the transdermal drug delivery process, based on the heterogeneous and nonlinear structures of the skin tissues, we developed a novel electromechanical method combining in vivo local skin impedance probing, subcutaneous micro-injection of colloidal nanoparticles, and transcutaneous electrical stimulation. Experiments on the nude mice using in vivo fluorescence imaging exhibited significantly different apparent diffusion patterns of the nanoparticles depending on the skin impedance: Anisotropic and isotropic patterns were observed upon injection into low and high impedance points, respectively. This result implies that the physical complexity in living tissues may cause anisotropic diffusion of drug carriers, and can be used as a parameter for controlling drug delivery process. This method also can be combined with microneedle-based drug release systems, micro-fabricated needle-electrodes, and/or advanced in vivo targeting/imaging technologies using nanoparticles.
Collapse
Affiliation(s)
- Baeckkyoung Sung
- Department of Physics and Astronomy, Seoul National University, Seoul, 151-747, South Korea
| | | | | | | | | |
Collapse
|
32
|
Hung CY, Sun PL, Chiang SJ, Jaw FS. In vitro differential diagnosis of clavus and verruca by a predictive model generated from electrical impedance. PLoS One 2014; 9:e93647. [PMID: 24705282 PMCID: PMC3976310 DOI: 10.1371/journal.pone.0093647] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2013] [Accepted: 03/08/2014] [Indexed: 11/18/2022] Open
Abstract
Background Similar clinical appearances prevent accurate diagnosis of two common skin diseases, clavus and verruca. In this study, electrical impedance is employed as a novel tool to generate a predictive model for differentiating these two diseases. Materials and Methods We used 29 clavus and 28 verruca lesions. To obtain impedance parameters, a LCR-meter system was applied to measure capacitance (C), resistance (Re), impedance magnitude (Z), and phase angle (θ). These values were combined with lesion thickness (d) to characterize the tissue specimens. The results from clavus and verruca were then fitted to a univariate logistic regression model with the generalized estimating equations (GEE) method. In model generation, log ZSD and θSD were formulated as predictors by fitting a multiple logistic regression model with the same GEE method. The potential nonlinear effects of covariates were detected by fitting generalized additive models (GAM). Moreover, the model was validated by the goodness-of-fit (GOF) assessments. Results Significant mean differences of the index d, Re, Z, and θ are found between clavus and verruca (p<0.001). A final predictive model is established with Z and θ indices. The model fits the observed data quite well. In GOF evaluation, the area under the receiver operating characteristics (ROC) curve is 0.875 (>0.7), the adjusted generalized R2 is 0.512 (>0.3), and the p value of the Hosmer-Lemeshow GOF test is 0.350 (>0.05). Conclusions This technique promises to provide an approved model for differential diagnosis of clavus and verruca. It could provide a rapid, relatively low-cost, safe and non-invasive screening tool in clinic use.
Collapse
Affiliation(s)
- Chien-Ya Hung
- Institute of Biomedical Engineering, National Taiwan University, Taipei, Taiwan
| | - Pei-Lun Sun
- Department of Dermatology, Mackay Memorial Hospital, Taipei, Taiwan
| | - Shu-Jen Chiang
- Institute of Zoology, National Taiwan University, Taipei, Taiwan
| | - Fu-Shan Jaw
- Institute of Biomedical Engineering, National Taiwan University, Taipei, Taiwan
- * E-mail:
| |
Collapse
|
33
|
Ngai SP, Jones AY. Changes in Skin Impedance and Heart Rate Variability with Application of Acu-TENS to BL 13 (Feishu). J Altern Complement Med 2013; 19:558-63. [DOI: 10.1089/acm.2012.0097] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Affiliation(s)
- Shirley P.C. Ngai
- Center for East-meets-West in Rehabilitation Sciences, Department of Rehabilitation Sciences, The Hong Kong Polytechnic University, Hong Kong
| | - Alice Y.M. Jones
- Center for East-meets-West in Rehabilitation Sciences, Department of Rehabilitation Sciences, The Hong Kong Polytechnic University, Hong Kong
| |
Collapse
|
34
|
Birgersson U, Birgersson E, Nicander I, Ollmar S. A methodology for extracting the electrical properties of human skin. Physiol Meas 2013; 34:723-36. [DOI: 10.1088/0967-3334/34/6/723] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
35
|
Callejón MA, Naranjo-Hernández D, Reina-Tosina J, Roa LM. Distributed circuit modeling of galvanic and capacitive coupling for intrabody communication. IEEE Trans Biomed Eng 2012; 59:3263-9. [PMID: 22736633 DOI: 10.1109/tbme.2012.2205382] [Citation(s) in RCA: 77] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Modeling of intrabody communication (IBC) entails the understanding of the interaction between electromagnetic fields and living tissues. At the same time, an accurate model can provide practical hints toward the deployment of an efficient and secure communication channel for body sensor networks. In the literature, two main IBC coupling techniques have been proposed: galvanic and capacitive coupling. Nevertheless, models that are able to emulate both coupling approaches have not been reported so far. In this paper, a simple model based on a distributed parameter structure with the flexibility to adapt to both galvanic and capacitive coupling has been proposed. In addition, experimental results for both coupling methods were acquired by means of two harmonized measurement setups. The model simulations have been subsequently compared with the experimental data, not only to show their validity but also to revise the practical frequency operation range for both techniques. Finally, the model, along with the experimental results, has also allowed us to provide some practical rules to optimally tackle IBC design.
Collapse
Affiliation(s)
- M Amparo Callejón
- Biomedical Engineering Group, University of Seville, Seville, Spain.
| | | | | | | |
Collapse
|
36
|
Abdul Sukor J, Redmond SJ, Chan GSH, Lovell NH. Signal quality measures for unsupervised blood pressure measurement. Physiol Meas 2012; 33:465-86. [DOI: 10.1088/0967-3334/33/3/465] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
37
|
Callejon MA, Roa LM, Reina-Tosina J, Naranjo-Hernandez D. Study of Attenuation and Dispersion Through the Skin in Intrabody Communications Systems. ACTA ACUST UNITED AC 2012; 16:159-65. [DOI: 10.1109/titb.2011.2171702] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|