1
|
Plumb JOM, Otto JM, Kumar SB, Bali S, Wakatsuki M, Schmidt WFJ, Montgomery HE, Grocott MPW, Levett DZ. Cardiopulmonary exercise testing before and after intravenous iron in preoperative patients: a prospective clinical study. Perioper Med (Lond) 2023; 12:31. [PMID: 37400931 DOI: 10.1186/s13741-023-00319-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2022] [Accepted: 06/16/2023] [Indexed: 07/05/2023] Open
Abstract
BACKGROUND Anemia is associated with impaired physical performance and adverse perioperative outcomes. Iron-deficiency anemia is increasingly treated with intravenous iron before elective surgery. We explored the relationship between exercise capacity, anemia, and total hemoglobin mass (tHb-mass) and the response to intravenous iron in anemic patients prior to surgery. METHODS A prospective clinical study was undertaken in patients having routine cardiopulmonary exercise testing (CPET) with a hemoglobin concentration ([Hb]) < 130 g.l-1 and iron deficiency/depletion. Patients underwent CPET and tHb-mass measurements before and a minimum of 14 days after receiving intravenous (i.v.) Ferric derisomaltose (Monofer®) at the baseline visit. Comparative analysis of hematological and CPET variables was performed pre and post-iron treatment. RESULTS Twenty-six subjects were recruited, of whom 6 withdrew prior to study completion. The remaining 20 (9 [45%] male; mean ± SD age 68 ± 10 years) were assessed 25 ± 7 days between baseline and the final visit. Following i.v. iron, increases were seen in [Hb] (mean ± SD) from 109 ± 14 to 116 ± 12 g l-1 (mean rise 6.4% or 7.3 g l-1, p = < 0.0001, 95% CI 4.5-10.1); tHb-mass from 497 ± 134 to 546 ± 139 g (mean rise 9.3% or 49 g, p = < 0.0001, 95% CI 29.4-69.2). Oxygen consumption at anerobic threshold ([Formula: see text] O2 AT) did not change (9.1 ± 1.7 to 9.8 ± 2.5 ml kg-1 min-1, p = 0.09, 95% CI - 0.13 - 1.3). Peak oxygen consumption ([Formula: see text] O2 peak) increased from 15.2 ± 4.1 to 16 ± 4.4 ml.kg.-1 min-1, p = 0.02, 95% CI 0.2-1.8) and peak work rate increased from 93 [67-112] watts to 96 [68-122] watts (p = 0.02, 95% CI 1.3-10.8). CONCLUSION Preoperative administration of intravenous iron to iron-deficient/deplete anemic patients is associated with increases in [Hb], tHb-mass, peak oxygen consumption, and peak work rate. Further appropriately powered prospective studies are required to ascertain whether improvements in tHb-mass and performance in turn lead to reductions in perioperative morbidity. TRIAL REGISTRATION ClinicalTrials.gov identifier: NCT 033 46213.
Collapse
Affiliation(s)
- James O M Plumb
- Perioperative and Critical Care Theme, NIHR Southampton Biomedical Research Centre, University Hospital Southampton NHS Foundation Trust/University of Southampton, Southampton, UK.
- Centre for Human Integrative Physiology, Faculty of Medicine, University of Southampton, Southampton, UK.
- Anaesthesia and Critical Care Research Unit, University Hospital Southampton NHSFT, Southampton, UK.
- Shackleton Department of Anaesthesia, University Hospital Southampton NHSFT, Southampton, UK.
| | - James M Otto
- Perioperative and Critical Care Theme, NIHR Southampton Biomedical Research Centre, University Hospital Southampton NHS Foundation Trust/University of Southampton, Southampton, UK
- Centre for Human Integrative Physiology, Faculty of Medicine, University of Southampton, Southampton, UK
- Anaesthesia and Critical Care Research Unit, University Hospital Southampton NHSFT, Southampton, UK
- Shackleton Department of Anaesthesia, University Hospital Southampton NHSFT, Southampton, UK
| | - Shriya B Kumar
- Perioperative and Critical Care Theme, NIHR Southampton Biomedical Research Centre, University Hospital Southampton NHS Foundation Trust/University of Southampton, Southampton, UK
| | - Sitara Bali
- Perioperative and Critical Care Theme, NIHR Southampton Biomedical Research Centre, University Hospital Southampton NHS Foundation Trust/University of Southampton, Southampton, UK
| | - Mai Wakatsuki
- Shackleton Department of Anaesthesia, University Hospital Southampton NHSFT, Southampton, UK
| | - Walter F J Schmidt
- Department of, Sports Medicine/Sports Physiology, University of Bayreuth, Bayreuth, Germany
| | - Hugh E Montgomery
- Centre for Human Health and Performance/Institute of Sport, Exercise and Health, University College London, London, UK
- NIHR University College London Hospitals Biomedical Research Centre, London, UK
| | - Michael P W Grocott
- Perioperative and Critical Care Theme, NIHR Southampton Biomedical Research Centre, University Hospital Southampton NHS Foundation Trust/University of Southampton, Southampton, UK
- Centre for Human Integrative Physiology, Faculty of Medicine, University of Southampton, Southampton, UK
- Anaesthesia and Critical Care Research Unit, University Hospital Southampton NHSFT, Southampton, UK
- Shackleton Department of Anaesthesia, University Hospital Southampton NHSFT, Southampton, UK
- Department of Anesthesiology, Duke University School of Medicine, Durham, NC, USA
| | - Denny Z Levett
- Perioperative and Critical Care Theme, NIHR Southampton Biomedical Research Centre, University Hospital Southampton NHS Foundation Trust/University of Southampton, Southampton, UK
- Centre for Human Integrative Physiology, Faculty of Medicine, University of Southampton, Southampton, UK
- Anaesthesia and Critical Care Research Unit, University Hospital Southampton NHSFT, Southampton, UK
- Shackleton Department of Anaesthesia, University Hospital Southampton NHSFT, Southampton, UK
| |
Collapse
|
2
|
Plumb JO, Otto JM, Kumar SB, Wright M, Schmidt W, Grocott MP, Montgomery HE. Application of the optimized carbon monoxide rebreathing method for the measurement of total haemoglobin mass in chronic liver disease. Physiol Rep 2020; 8:e14402. [PMID: 32207243 PMCID: PMC7090373 DOI: 10.14814/phy2.14402] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2020] [Revised: 02/20/2020] [Accepted: 02/23/2020] [Indexed: 01/07/2023] Open
Abstract
BACKGROUND Anemia is common in liver cirrhosis. This generally infers a fall in total hemoglobin mass (tHb-mass). However, hemoglobin concentration ([Hb]) may fall due to an expansion in plasma volume (PV). The "optimized carbon monoxide rebreathing method" (oCOR) measures tHb-mass directly and PV (indirectly using hematocrit). It relies upon carboxyhemoglobin (COHb) distribution throughout the entire circulation. In healthy subjects, such distribution is complete within 6-8 min. Given the altered circulatory dynamics in cirrhosis, we sought in this pilot study, to assess whether this was true in cirrhosis. The primary aim was to ascertain if the standard timings for the oCOR were applicable to patients with chronic liver disease and cirrhosis. The secondary aim was to explore the applicability of standard CO dosing methodologies to this patient population. METHODS Sixteen patients with chronic liver parenchymal disease were studied. However, tHb-mass was determined using the standard oCOR technique before elective paracentesis. Three subjects had an inadequate COHb% rise. In the remaining 13 (11 male), mean ± standard deviation (SD) age was 52 ± 13.8 years, body mass 79.1 ± 11.4 kg, height 175 ± 6.8 cm. To these, mean ± SD dose of carbon monoxide (CO) gas administered was 0.73 ± 0.13 ml/kg COHb values at baseline, 6 and 8 min (and "7-min value") were compared to those at 10, 12, 15 and 20 min after CO rebreathing. RESULTS The "7-min value" for median COHb% (IQR) of 6.30% (6.21%-7.47%) did not differ significantly from those at subsequent time points (8 min: 6.30% (6.21%-7.47%), 10 min: 6.33% (6.00%-7.50%), 12 min: 6.33% (5.90%-7.40%), 15 min: 6.37% (5.80%-7.33%), 20 min: 6.27% (5.70%-7.20%)). Mean difference in calculated tHb-mass between minute 7 and minute 20 was only 4.1 g, or 0.6%, p = .68. No subjects reported any adverse effects. CONCLUSIONS The oCOR method can be safely used to measure tHb-mass in patients with chronic liver disease and ascites, without adjustment of blood sample timings. Further work might refine and validate appropriate dosing regimens.
Collapse
Affiliation(s)
- James O.M. Plumb
- Respiratory and Critical Care Research AreaNIHR Biomedical Research CentreUniversity Hospital Southampton NHS Foundation Trust / University of SouthamptonSouthamptonUK
- Centre for Human Integrative PhysiologyFaculty of MedicineUniversity of SouthamptonSouthamptonUK
- Anaesthesia, Perioperative Medicine and Critical Care Research UnitUniversity Hospital Southampton NHSFTSouthamptonUK
- Shackleton Department of AnaesthesiaUniversity Hospital Southampton NHSFTSouthamptonUK
| | - James M. Otto
- Respiratory and Critical Care Research AreaNIHR Biomedical Research CentreUniversity Hospital Southampton NHS Foundation Trust / University of SouthamptonSouthamptonUK
- Centre for Human Integrative PhysiologyFaculty of MedicineUniversity of SouthamptonSouthamptonUK
- Anaesthesia, Perioperative Medicine and Critical Care Research UnitUniversity Hospital Southampton NHSFTSouthamptonUK
- Shackleton Department of AnaesthesiaUniversity Hospital Southampton NHSFTSouthamptonUK
- University of Southampton Medical SchoolSouthamptonUK
| | - Shriya B. Kumar
- Centre for Human Integrative PhysiologyFaculty of MedicineUniversity of SouthamptonSouthamptonUK
- University of Southampton Medical SchoolSouthamptonUK
| | - Mark Wright
- Department of HepatologyUniversity Hospital SouthamptonSouthamptonUK
| | - Walter Schmidt
- Department of Sports Medicine/Sports PhysiologyUniversity of BayreuthBayreuthGermany
| | - Michael P.W. Grocott
- Respiratory and Critical Care Research AreaNIHR Biomedical Research CentreUniversity Hospital Southampton NHS Foundation Trust / University of SouthamptonSouthamptonUK
- Centre for Human Integrative PhysiologyFaculty of MedicineUniversity of SouthamptonSouthamptonUK
- Anaesthesia, Perioperative Medicine and Critical Care Research UnitUniversity Hospital Southampton NHSFTSouthamptonUK
- Shackleton Department of AnaesthesiaUniversity Hospital Southampton NHSFTSouthamptonUK
- Department of AnesthesiologyDuke University School of MedicineDurhamNCUSA
| | - Hugh E. Montgomery
- Centre for Human Health and Performance/ Institute of Sport, Exercise and HealthUniversity College London, and NIHR University College London Hospitals Biomedical Research CentreLondonUK
| |
Collapse
|
3
|
Otto JM, Plumb JOM, Wakeham D, Clissold E, Loughney L, Schmidt W, Montgomery HE, Grocott MPW, Richards T. Total haemoglobin mass, but not haemoglobin concentration, is associated with preoperative cardiopulmonary exercise testing-derived oxygen-consumption variables. Br J Anaesth 2018; 118:747-754. [PMID: 28510737 DOI: 10.1093/bja/aew445] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/13/2016] [Indexed: 01/22/2023] Open
Abstract
Background Cardiopulmonary exercise testing (CPET) measures peak exertional oxygen consumption ( V˙O2peak ) and that at the anaerobic threshold ( V˙O2 at AT, i.e. the point at which anaerobic metabolism contributes substantially to overall metabolism). Lower values are associated with excess postoperative morbidity and mortality. A reduced haemoglobin concentration ([Hb]) results from a reduction in total haemoglobin mass (tHb-mass) or an increase in plasma volume. Thus, tHb-mass might be a more useful measure of oxygen-carrying capacity and might correlate better with CPET-derived fitness measures in preoperative patients than does circulating [Hb]. Methods Before major elective surgery, CPET was performed, and both tHb-mass (optimized carbon monoxide rebreathing method) and circulating [Hb] were determined. Results In 42 patients (83% male), [Hb] was unrelated to V˙O2 at AT and V˙O2peak ( r =0.02, P =0.89 and r =0.04, P =0.80, respectively) and explained none of the variance in either measure. In contrast, tHb-mass was related to both ( r =0.661, P <0.0001 and r =0.483, P =0.001 for V˙O2 at AT and V˙O2peak , respectively). The tHb-mass explained 44% of variance in V˙O2 at AT ( P <0.0001) and 23% in V˙O2peak ( P =0.001). Conclusions In contrast to [Hb], tHb-mass is an important determinant of physical fitness before major elective surgery. Further studies should determine whether low tHb-mass is predictive of poor outcome and whether targeted increases in tHb-mass might thus improve outcome.
Collapse
Affiliation(s)
- J M Otto
- Division of Surgery and Interventional Science, University College London, London, UK
| | - J O M Plumb
- Anaesthesia and Critical Care Research Unit, University Hospital Southampton NHS Foundation Trust, Southampton, UK.,Integrative Physiology and Critical Illness Group, Clinical and Experimental Sciences, Faculty of Medicine, University of Southampton, University Road, Southampton, UK.,Critical Care Research Area, Southampton NIHR Respiratory Biomedical Research Unit, Southampton, UK
| | - D Wakeham
- Cardiff School of Sport, Cardiff Metropolitan University, Cardiff, UK.,Centre for Human Health and Performance/Institute for Sport, Exercise and Health, University College London, UK
| | - E Clissold
- Anaesthesia and Critical Care Research Unit, University Hospital Southampton NHS Foundation Trust, Southampton, UK.,Integrative Physiology and Critical Illness Group, Clinical and Experimental Sciences, Faculty of Medicine, University of Southampton, University Road, Southampton, UK.,Critical Care Research Area, Southampton NIHR Respiratory Biomedical Research Unit, Southampton, UK
| | - L Loughney
- Anaesthesia and Critical Care Research Unit, University Hospital Southampton NHS Foundation Trust, Southampton, UK.,Integrative Physiology and Critical Illness Group, Clinical and Experimental Sciences, Faculty of Medicine, University of Southampton, University Road, Southampton, UK.,Critical Care Research Area, Southampton NIHR Respiratory Biomedical Research Unit, Southampton, UK
| | - W Schmidt
- Department of Sports Medicine/Sports Physiology, University of Bayreuth, Bayreuth, Germany
| | - H E Montgomery
- Centre for Human Health and Performance/Institute for Sport, Exercise and Health, University College London, UK.,NIHR University College London Hospitals Biomedical Research Centre, London, UK
| | - M P W Grocott
- Anaesthesia and Critical Care Research Unit, University Hospital Southampton NHS Foundation Trust, Southampton, UK.,Integrative Physiology and Critical Illness Group, Clinical and Experimental Sciences, Faculty of Medicine, University of Southampton, University Road, Southampton, UK.,Critical Care Research Area, Southampton NIHR Respiratory Biomedical Research Unit, Southampton, UK
| | - T Richards
- Division of Surgery and Interventional Science, University College London, London, UK
| |
Collapse
|
4
|
Plumb JOM, Kumar S, Otto J, Schmidt W, Richards T, Montgomery HE, Grocott MPW. Replicating measurements of total hemoglobin mass (tHb-mass) within a single day: precision of measurement; feasibility and safety of using oxygen to expedite carbon monoxide clearance. Physiol Rep 2018; 6:e13829. [PMID: 30203465 PMCID: PMC6131726 DOI: 10.14814/phy2.13829] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2018] [Accepted: 07/21/2018] [Indexed: 11/24/2022] Open
Abstract
Hemoglobin concentration ([Hb]) is a function of total hemoglobin mass (tHb-mass) and plasma volume. [Hb] may fall by dilution due to plasma volume expansion and changes in the perioperative period may therefore correlate poorly with blood loss. A simple, reliable, repeatable way to measure plasma volume and tHb-mass would have substantial clinical utility. The "optimized carbon monoxide re-breathing method" (oCOR) meets these criteria. However, it is recommended that a minimum of 12 h (when breathing room air) is left between repeat measurements. Twenty-four subjects underwent 3 days of testing. Two oCOR tests were performed (T1 and T2), 3 h apart, with a different CO clearance method employed between tests aiming to keep the carboxyhemoglobin level below 10%. The primary aim was to ascertain whether tHb-mass testing could be safely repeated within 3 h if carboxyhemoglobin levels were actively reduced by breathing supplemental oxygen (PROCA ). Secondary aims were to compare two other clearance methods; moderate exercise (PROCB ), or a combination of the two (PROCC ). Finally, the reliability of the oCOR method was assessed. Mean (SD) tHb-mass was 807.9 ± (189.7 g) (for T1 on day 1). PROCA lowered the carboxyhemoglobin level from the end of T1 (mean 6.64%) to the start of T2 (mean 2.95%) by a mean absolute value of 3.69%. For PROCB and PROCC the mean absolute decreases in carboxyhemoglobin were 4.00% and 4.31%, respectively. The fall in carboxyhemoglobin between T1 and T2 was greatest in PROCC ; this was statistically significantly lower than that of PROCA (P = 0.0039) and PROCB (P = 0.0289). The test-retest reliability for the measurement of total hemoglobin mass was good with a mean typical error (TE) of 2.0%. The oCOR method is safe and can be repeated within 3 h when carbon monoxide is suitably cleared between tests. Using oxygen therapy alone adequately achieves this.
Collapse
Affiliation(s)
- James O. M. Plumb
- Respiratory and Critical Care Research AreaNIHR Biomedical Research CentreUniversity Hospital Southampton NHS Foundation TrustUniversity of SouthamptonSouthamptonUnited Kingdom
- Centre for Human Integrative PhysiologyFaculty of MedicineUniversity of SouthamptonSouthamptonUnited Kingdom
- Anaesthesia and Critical Care Research UnitUniversity Hospital Southampton NHSFTSouthamptonUnited Kingdom
- Shackleton Department of AnaesthesiaUniversity Hospital Southampton NHSFTSouthamptonUnited Kingdom
| | - Shriya Kumar
- Anaesthesia and Critical Care Research UnitUniversity Hospital Southampton NHSFTSouthamptonUnited Kingdom
- University of Southampton Medical SchoolSouthamptonUnited Kingdom
| | - James Otto
- Shackleton Department of AnaesthesiaUniversity Hospital Southampton NHSFTSouthamptonUnited Kingdom
- Division of Surgery and Interventional ScienceUniversity College LondonLondonUnited Kingdom
| | - Walter Schmidt
- Department of Sports Medicine/Sports PhysiologyUniversity of BayreuthBayreuthGermany
| | - Toby Richards
- Division of Surgery and Interventional ScienceUniversity College LondonLondonUnited Kingdom
| | - Hugh E. Montgomery
- Centre for Human Health and PerformanceInstitute of Sport, Exercise and HealthUniversity College LondonNIHR University College London Hospitals Biomedical Research CentreLondonUnited Kingdom
| | - Mike P. W. Grocott
- Respiratory and Critical Care Research AreaNIHR Biomedical Research CentreUniversity Hospital Southampton NHS Foundation TrustUniversity of SouthamptonSouthamptonUnited Kingdom
- Centre for Human Integrative PhysiologyFaculty of MedicineUniversity of SouthamptonSouthamptonUnited Kingdom
- Anaesthesia and Critical Care Research UnitUniversity Hospital Southampton NHSFTSouthamptonUnited Kingdom
- Shackleton Department of AnaesthesiaUniversity Hospital Southampton NHSFTSouthamptonUnited Kingdom
- Department of AnesthesiologyDuke University School of MedicineDurhamNorth Carolina
| |
Collapse
|
5
|
Trudel G, Uhthoff HK, Laneuville O. Hemolysis during and after 21 days of head-down-tilt bed rest. Physiol Rep 2018; 5:5/24/e13469. [PMID: 29263114 PMCID: PMC5742697 DOI: 10.14814/phy2.13469] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2017] [Revised: 09/12/2017] [Accepted: 09/14/2017] [Indexed: 12/22/2022] Open
Abstract
Hemoconcentration is observed in bed rest studies, descent from altitude, and exposure to microgravity. Hemoconcentration triggers erythrocyte losses to subsequently normalize erythrocyte concentration. The mechanisms of erythrocyte loss may involve enhanced hemolysis, but has never been measured directly in bed rest studies. Steady‐state hemolysis was evaluated by measuring two heme degradation products, endogenous carbon monoxide concentration [CO] and urobilinogen in feces, in 10 healthy men, before, during, and after two campaigns of 21 days of 6° head‐down‐tilt (HDT) bed rest. The subjects were hemoconcentrated at 10 and 21 days of bed rest: mean concentrations of hemoglobin (15.0 ± 0.2 g/L and 14.6 ± 0.1 g/L, respectively) and erythrocytes (5.18 ± 0.06E6/μL and 5.02 ± 0.06E6/μL, respectively) were increased compared to baseline (all Ps < 0.05). In contrast, mean hemoglobin mass (743 ± 19 g) and number of erythrocytes (2.56 ± 0.07E13) were decreased at 21 days of bed rest (both Ps < 0.05). Indicators of hemolysis mean [CO] (1660 ± 49 ppb and 1624 ± 48 ppb, respectively) and fecal urobilinogen concentration (180 ± 23 mg/day and 199 ± 22 mg/day, respectively) were unchanged at 10 and 21 days of bed rest compared to baseline (both Ps > 0.05). A significant decrease in [CO] (−505 ppb) was measured at day 28 after bed rest. HDT bed rest caused hemoconcentration in parallel with lower hemoglobin mass. Circulating indicators of hemolysis remained unchanged throughout bed rest supporting that enhanced hemolysis did not contribute significantly to erythrocyte loss during the hemoconcentration of bed rest. At day 28 after bed rest, decreased hemolysis accompanied the recovery of erythrocytes, a novel finding.
Collapse
Affiliation(s)
- Guy Trudel
- The Ottawa Hospital Rehabilitation Centre, Ottawa, Ontario, Canada .,University of Ottawa, Faculty of Medicine, Department of Medicine, Ottawa, Ontario, Canada.,Ottawa Hospital Research Institute, Clinical Epidemiology Program, Ottawa, Ontario, Canada
| | - Hans K Uhthoff
- Faculty of Medicine, University of Ottawa, Ottawa, Ontario, Canada
| | - Odette Laneuville
- Department of Biology, Faculty of Science, University of Ottawa, Ottawa, Ontario, Canada
| |
Collapse
|
6
|
Otto JM, Plumb JOM, Clissold E, Kumar SB, Wakeham DJ, Schmidt W, Grocott MPW, Richards T, Montgomery HE. Hemoglobin concentration, total hemoglobin mass and plasma volume in patients: implications for anemia. Haematologica 2017; 102:1477-1485. [PMID: 28596281 PMCID: PMC5685237 DOI: 10.3324/haematol.2017.169680] [Citation(s) in RCA: 51] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2017] [Accepted: 06/06/2017] [Indexed: 11/09/2022] Open
Abstract
In practice, clinicians generally consider anemia (circulating hemoglobin concentration < 120 g.l-1 in non-pregnant females and < 130 g.l-1 in males) as due to impaired hemoglobin synthesis or increased erythrocyte loss or destruction. Rarely is a rise in plasma volume relative to circulating total hemoglobin mass considered as a cause. But does this matter? We explored this issue in patients, measuring hemoglobin concentration, total hemoglobin mass (optimized carbon monoxide rebreathing method) and thereby calculating plasma volume in healthy volunteers, surgical patients, and those with inflammatory bowel disease, chronic liver disease or heart failure. We studied 109 participants. Hemoglobin mass correlated well with its concentration in the healthy, surgical and inflammatory bowel disease groups (r=0.687-0.871, P<0.001). However, they were poorly related in liver disease (r=0.410, P=0.11) and heart failure patients (r=0.312, P=0.16). Here, hemoglobin mass explained little of the variance in its concentration (adjusted R2=0.109 and 0.052; P=0.11 and 0.16), whilst plasma volume did (R2 change 0.724 and 0.805 in heart and liver disease respectively, P<0.0001). Exemplar patients with identical (normal or raised) total hemoglobin masses were diagnosed as profoundly anemic (or not) depending on differences in plasma volume that had not been measured or even considered as a cause. The traditional inference that anemia generally reflects hemoglobin deficiency may be misleading, potentially resulting in inappropriate tests and therapeutic interventions to address 'hemoglobin deficiency' not 'plasma volume excess'. Measurement of total hemoglobin mass and plasma volume is now simple, cheap and safe, and its more routine use is advocated.
Collapse
Affiliation(s)
- James M Otto
- Division of Surgery and Interventional Science, University College London, UK
| | - James O M Plumb
- Anaesthesia and Critical Care Research Unit, University Hospital Southampton NHS Foundation Trust, Southampton, UK.,Integrative Physiology and Critical Illness Group, Clinical and Experimental Sciences, Faculty of Medicine, University of Southampton, UK.,Critical Care Research Area, Southampton NIHR Respiratory Biomedical Research Unit, Southampton, UK
| | - Eleri Clissold
- Anaesthesia and Critical Care Research Unit, University Hospital Southampton NHS Foundation Trust, Southampton, UK.,Integrative Physiology and Critical Illness Group, Clinical and Experimental Sciences, Faculty of Medicine, University of Southampton, UK.,Critical Care Research Area, Southampton NIHR Respiratory Biomedical Research Unit, Southampton, UK
| | - Shriya B Kumar
- Anaesthesia and Critical Care Research Unit, University Hospital Southampton NHS Foundation Trust, Southampton, UK.,Integrative Physiology and Critical Illness Group, Clinical and Experimental Sciences, Faculty of Medicine, University of Southampton, UK.,Critical Care Research Area, Southampton NIHR Respiratory Biomedical Research Unit, Southampton, UK
| | - Denis J Wakeham
- School of Sport, Physiology and Health Group, Cardiff Metropolitan University, UK
| | - Walter Schmidt
- Department of Sports Medicine/Sports Physiology, University of Bayreuth, Germany
| | - Michael P W Grocott
- Anaesthesia and Critical Care Research Unit, University Hospital Southampton NHS Foundation Trust, Southampton, UK.,Integrative Physiology and Critical Illness Group, Clinical and Experimental Sciences, Faculty of Medicine, University of Southampton, UK.,Critical Care Research Area, Southampton NIHR Respiratory Biomedical Research Unit, Southampton, UK
| | - Toby Richards
- Division of Surgery and Interventional Science, University College London, UK
| | - Hugh E Montgomery
- Centre for Human Health and Performance/Institute of Sport, Exercise and Health, University College London, and NIHR University College London Hospitals Biomedical Research Centre, UK
| |
Collapse
|
7
|
Fagoni N, Breenfeldt Andersen A, Oberholzer L, Haider T, Meinild Lundby AK, Lundby C. Reliability and validity of non-invasive determined haemoglobin mass and blood volumes. Clin Physiol Funct Imaging 2017; 38:240-245. [DOI: 10.1111/cpf.12406] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2016] [Accepted: 11/07/2016] [Indexed: 11/30/2022]
Affiliation(s)
- Nazzareno Fagoni
- Zurich Center of Integrative Human Physiology; Institute of Physiology; University of Zürich; Zürich Switzerland
- Department of Molecular and Translational Medicine; University of Brescia; Brescia Italy
| | - Andreas Breenfeldt Andersen
- Zurich Center of Integrative Human Physiology; Institute of Physiology; University of Zürich; Zürich Switzerland
- Department of Nutrition, Exercise and Sports (NEXS); University of Copenhagen; Copenhagen Denmark
| | - Laura Oberholzer
- Zurich Center of Integrative Human Physiology; Institute of Physiology; University of Zürich; Zürich Switzerland
| | - Thomas Haider
- Zurich Center of Integrative Human Physiology; Institute of Physiology; University of Zürich; Zürich Switzerland
| | - Anne-Kristine Meinild Lundby
- Zurich Center of Integrative Human Physiology; Institute of Physiology; University of Zürich; Zürich Switzerland
| | - Carsten Lundby
- Zurich Center of Integrative Human Physiology; Institute of Physiology; University of Zürich; Zürich Switzerland
| |
Collapse
|
8
|
Gibson OR, Turner G, Tuttle JA, Taylor L, Watt PW, Maxwell NS. Heat acclimation attenuates physiological strain and the HSP72, but not HSP90α, mRNA response to acute normobaric hypoxia. J Appl Physiol (1985) 2015. [DOI: 10.1152/japplphysiol.00332.2015] [Citation(s) in RCA: 39] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
Heat acclimation (HA) attenuates physiological strain in hot conditions via phenotypic and cellular adaptation. The aim of this study was to determine whether HA reduced physiological strain, and heat shock protein (HSP) 72 and HSP90α mRNA responses in acute normobaric hypoxia. Sixteen male participants completed ten 90-min sessions of isothermic HA (40°C/40% relative humidity) or exercise training [control (CON); 20°C/40% relative humidity]. HA or CON were preceded (HYP1) and proceeded (HYP2) by a 30-min normobaric hypoxic exposure [inspired O2 fraction = 0.12; 10-min rest, 10-min cycling at 40% peak O2 uptake (V̇o2 peak), 10-min cycling at 65% V̇o2 peak]. HA induced greater rectal temperatures, sweat rate, and heart rates (HR) than CON during the training sessions. HA, but not CON, reduced resting rectal temperatures and resting HR and increased sweat rate and plasma volume. Hemoglobin mass did not change following HA nor CON. HSP72 and HSP90α mRNA increased in response to each HA session, but did not change with CON. HR during HYP2 was lower and O2 saturation higher at 65% V̇o2 peak following HA, but not CON. O2 uptake/HR was greater at rest and 65% V̇o2 peak in HYP2 following HA, but was unchanged after CON. At rest, the respiratory exchange ratio was reduced during HYP2 following HA, but not CON. The increase in HSP72 mRNA during HYP1 did not occur in HYP2 following HA. In CON, HSP72 mRNA expression was unchanged during HYP1 and HYP2. In HA and CON, increases in HSP90α mRNA during HYP1 were maintained in HYP2. HA reduces physiological strain, and the transcription of HSP72, but not HSP90α mRNA in acute normobaric hypoxia.
Collapse
Affiliation(s)
- Oliver R. Gibson
- Centre for Sport and Exercise Science and Medicine (SESAME), Environmental Extremes Laboratory, University of Brighton, Welkin Human Performance Laboratories, Eastbourne, United Kingdom
| | - Gareth Turner
- Centre for Sport and Exercise Science and Medicine (SESAME), Environmental Extremes Laboratory, University of Brighton, Welkin Human Performance Laboratories, Eastbourne, United Kingdom
- English Institute of Sport, EIS Performance Centre, Loughborough University, Loughborough, United Kingdom; and
| | - James A. Tuttle
- Muscle Cellular and Molecular Physiology (MCMP) and Applied Sport and Exercise Science (ASEP) Research Groups, Department of Sport Science and Physical Activity, Institute of Sport and Physical Activity Research (ISPAR), University of Bedfordshire, Bedfordshire, United Kingdom
| | - Lee Taylor
- Muscle Cellular and Molecular Physiology (MCMP) and Applied Sport and Exercise Science (ASEP) Research Groups, Department of Sport Science and Physical Activity, Institute of Sport and Physical Activity Research (ISPAR), University of Bedfordshire, Bedfordshire, United Kingdom
| | - Peter W. Watt
- Centre for Sport and Exercise Science and Medicine (SESAME), Environmental Extremes Laboratory, University of Brighton, Welkin Human Performance Laboratories, Eastbourne, United Kingdom
| | - Neil S. Maxwell
- Centre for Sport and Exercise Science and Medicine (SESAME), Environmental Extremes Laboratory, University of Brighton, Welkin Human Performance Laboratories, Eastbourne, United Kingdom
| |
Collapse
|