1
|
Li X, Steigerwalt D, Rehani MM. T-shirt size as a classification for body habitus in computed tomography (CT) and development of size-based dose reference levels for different indications. Eur J Radiol 2022; 151:110289. [PMID: 35397408 DOI: 10.1016/j.ejrad.2022.110289] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/25/2021] [Revised: 03/25/2022] [Accepted: 03/31/2022] [Indexed: 11/30/2022]
Abstract
PURPOSE To examine the impact of patient size on dose indices and develop size-based reference levels (50th and 75th percentiles) for 20 body CT exams for routine and organ-specific clinical indications. METHODS Based on effective diameter estimated from adult body CT, each acquisition was classified into T-shirt size as XXS, XS, S, M, L, XL, and XXL. Radiation dose indices for each size and each exam type were correlated. RESULTS About 0.93 million CT exams from 256 CT facilities in the United States were analysed. Taking T-shirt size M as a reference, the CTDIvol for other sizes were: XXS (∼60%), XS (∼65%), S (∼75%), L (∼130%), XL (∼165%), XXL (∼210%), or grossly small patients received about 60% of the dose as compared to M sized patients and XXL required doubling the dose. Taking ratio of the dose indices of the largest to smallest size, it was evident that SSDE variation was much less (about 50%) than that in CTDIvol, but there was still nearly 40 to 220% variation in SSDE across the range of t-shirt sizes. The 50th and 75th percentile values are presented for CTDIvol, SSDE and DLP for each of the 20 CT exams and for each of the seven T-shirt sizes. CONCLUSIONS A novel approach expressing body habitus in terms of T-shirt size is not only simple and intuitive, but it also provides a tool to have a perception of differences in dose metrices among patients of different body build.
Collapse
Affiliation(s)
- Xinhua Li
- Massachusetts General Hospital, 55 Fruit Str, Boston, MA 02114, USA
| | | | - Madan M Rehani
- Massachusetts General Hospital, 55 Fruit Str, Boston, MA 02114, USA.
| |
Collapse
|
2
|
Rehani MM, Brady Z. Contemporary issues in radiation protection in medical imaging: introductory editorial. Br J Radiol 2021; 94:bjr20219004. [PMID: 34545765 DOI: 10.1259/bjr.20219004] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022] Open
Affiliation(s)
- Madan M Rehani
- Department of Radiology, Massachusetts General Hospital, Boston, MA, United States
| | - Zoe Brady
- Department of Radiology, Alfred Health, Melbourne, Australia.,Department of Neuroscience, Monash University, Melbourne, Australia
| |
Collapse
|
3
|
Vano E. Why is radiological protection different in medicine? Sievert Memorial Lecture. JOURNAL OF RADIOLOGICAL PROTECTION : OFFICIAL JOURNAL OF THE SOCIETY FOR RADIOLOGICAL PROTECTION 2021; 41:S128-S138. [PMID: 33971634 DOI: 10.1088/1361-6498/abffc5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/15/2021] [Accepted: 05/10/2021] [Indexed: 06/12/2023]
Abstract
There are many aspects of radiological protection in medicine that are different from other areas of activity using ionising radiation. In this paper, the author presents and justify some of these differences and highlight the reasons for and benefits of this consideration for the medical field. It is important to understand the differences as we are all likely to be patients at some point in our lives and be exposed to ionising radiation for imaging procedures several times and, in some cases, for therapeutic indications. The work done by the International Commission on Radiological Protection and other international organisations to produce and recommend a consistent system of radiological protection in medicine for the safe use of ionising radiation in medical practices must be highlighted. We should understand why we do not apply dose limits and dose constraints to patients, as well as why we have three levels of justification when considering the use of ionising radiation for patients. We highlight the relevance of personalised radiation protection in parallel to personalised medical practice, and the importance of an integrated approach for occupational and patient protection, especially for interventional procedures. We also cover the differences between patients and volunteers in biomedical research, the importance of radiation safety in quality assurance programmes (including the consideration of unintended and accidental exposures) for some clinical practices, and the relevance of education and training in radiological protection for medical and health professionals and information on radiation risks for patients. Finally, the ethical issues with regard to the safe use of ionising radiation in medicine and the impact of new technology will be addressed.
Collapse
Affiliation(s)
- Eliseo Vano
- Radiology Department, Complutense University Madrid and Instituto de Investigación Sanitaria Hospital Clínico San Carlos (IdISSC), Madrid, Spain
| |
Collapse
|
4
|
Vano E, Frija G, Loose R, Paulo G, Efstathopoulos E, Granata C, Andersson J. Dosimetric quantities and effective dose in medical imaging: a summary for medical doctors. Insights Imaging 2021; 12:99. [PMID: 34255191 PMCID: PMC8276901 DOI: 10.1186/s13244-021-01041-2] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2021] [Accepted: 06/15/2021] [Indexed: 12/21/2022] Open
Abstract
This review presents basic information on the dosimetric quantities used in medical imaging for reporting patient doses and establishing diagnostic reference levels. The proper use of the radiation protection quantity "effective dose" to compare doses delivered by different radiological procedures and different imaging modalities with its uncertainties and limitations, is summarised. The estimates of population doses required by the European Directive on Basic Safety Standards is commented on. Referrers and radiologists should be familiar with the dose quantities to inform patients about radiation risks and benefits. The application of effective dose on the cumulative doses from recurrent imaging procedures is also discussed. Patient summary: Basic information on the measurement units (dosimetric quantities) used in medical imaging for reporting radiation doses should be understandable to patients. The Working Group on "Dosimetry for imaging in clinical practice" recommended that a brief explanation on the used dosimetric quantities and units included in the examination imaging report, should be available for patients. The use of the quantity "effective dose" to compare doses to which patients are exposed to from different radiological procedures and its uncertainties and limitations, should also be explained in plain language. This is also relevant for the dialog on to the cumulative doses from recurrent imaging procedures. The paper summarises these concepts, including the need to estimate the population doses required by the European Directive on Basic Safety Standards. Referrers and radiologists should be familiar with the dose quantities to inform patients about radiation risks and benefits.
Collapse
Affiliation(s)
- Eliseo Vano
- Radiology Department, Complutense University, 28040, Madrid, Spain.
| | - Guy Frija
- Université de Paris, 12 Rue de l'École de Médecine, 75006, Paris, France
| | - Reinhard Loose
- Institute of Medical Physics, Hospital Nuremberg, Prof.-Ernst-Nathan-Str. 1, 90419, Nuremberg, Germany
| | - Graciano Paulo
- ESTESC-Coimbra Health School, Medical Imaging and Radiotherapy Department, Instituto Politécnico de Coimbra, Rua 5 de Outubro, S. Martinho Do Bispo, 3046-854, Coimbra, Portugal
| | - Efstathios Efstathopoulos
- 2Nd Department of Radiology, Medical Physics Unit, National and Kapodistrian University of Athens, Attikon University Hospital, 12462, Athens, Greece
| | - Claudio Granata
- Department of Paediatric Radiology, Institute for Maternal and Child Health - IRCCS "Burlo Garofolo", Trieste, Italy
| | - Jonas Andersson
- Department of Radiation Sciences, Umea University, Umeå, Sweden
| | | |
Collapse
|
5
|
Rehani MM. Old enemy, new threat: you can't solve today's problems with yesterday's solution. JOURNAL OF RADIOLOGICAL PROTECTION : OFFICIAL JOURNAL OF THE SOCIETY FOR RADIOLOGICAL PROTECTION 2021; 41:452-458. [PMID: 33535195 DOI: 10.1088/1361-6498/abe2ba] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/23/2021] [Accepted: 02/03/2021] [Indexed: 06/12/2023]
Abstract
The radiation protection principles of justification, optimization, and dose limitation as enumerated by the International Commission on Radiological Protection have been guiding light for the profession for over three decades. The dose limitation does not apply to medical exposure but keeping patients' doses low is achieved through optimization, particularly by developing and using diagnostic reference levels (DRLs). There are new findings that demonstrate that despite using the best possible approaches to justification and optimization including as well use of DRLs, a very large number of patients are receiving doses in excess of 100 mSv of effective dose or organ doses exceeding 100 mGy. A non-ignorable fraction of patients is receiving such high doses in a single day. The magnitude of such patients creates the need for a relook into the principles with the intent to understand what can be done to attend to today's problems. A look at other areas such as approaches, and principles used in the pharmaceutical industry and in traffic management throws some light into what can be learnt from these examples. It appears that the system needs to be enriched to deal with the protection of the individual patient. The currently available approaches and even the principles are largely based on the protection of the population or group of patients. The third level of justification for individual needs further refinement to take into account series of imaging many patients are needing, and cumulative radiation doses involved, many of which happen in a short duration of 1 to 5 years. There is every likelihood of patient radiation doses continuing to increase further that underscores the need for timely attention. This paper provides several suggestions to deal with the situation.
Collapse
Affiliation(s)
- Madan M Rehani
- Radiology Department, Massachusetts General Hospital, 175 Cambridge Str., Suite 244, Boston, MA, United States of America
| |
Collapse
|
6
|
Frija G, Damilakis J, Paulo G, Loose R, Vano E. Cumulative effective dose from recurrent CT examinations in Europe: proposal for clinical guidance based on an ESR EuroSafe Imaging survey. Eur Radiol 2021; 31:5514-5523. [PMID: 33710370 PMCID: PMC8270793 DOI: 10.1007/s00330-021-07696-1] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2020] [Revised: 11/24/2020] [Accepted: 12/17/2020] [Indexed: 01/31/2023]
Abstract
In recent years, the issue of cumulative effective dose received from recurrent computed tomography examinations has become a subject of increasing concern internationally. Evidence, predominantly from the USA, has shown that a significant number of patients receive a cumulative effective dose of 100 mSv or greater. To obtain a European perspective, EuroSafe Imaging carried out a survey to collect European data on cumulative radiation exposure of patients from recurrent computed tomography examinations. The survey found that a relatively low percentage of patients (0.5%) received a cumulative effective dose equal to or higher than 100 mSv from computed tomography, most of them having an oncological disease. However, there is considerable variation between institutions as these values ranged from 0 to 2.72%, highlighting that local practice or, depending on the institution and its medical focus, local patient conditions are likely to be a significant factor in the levels of cumulative effective dose received, rather than this simply being a global phenomenon. This paper also provides some practical actions to support the management of cumulative effective dose and to refine or improve practice where recurrent examinations are required. These actions are focused around increasing awareness of referring physicians through encouraging local dialogue, actions focused on optimisation where a team approach is critical, better use of modern equipment and the use of Dose Management and Clinical Decision Support Systems together with focused clinical audits. The proper use of cumulative effective dose should be part of training programmes for referrers and practitioners, including what information to give to patients. Radiation is used to the benefit of patients in diagnostic procedures such as CT examinations, and in therapeutic procedures like the external radiation treatment for cancer. However, radiation is also known to increase the risk of cancer. To oversee this risk, the cumulative effective dose (CED) received by a patient from imaging procedures over his or her life is important. In this paper, the authors, on behalf of EuroSafe Imaging, report on a survey carried out in Europe that aims to estimate the proportion of patients that undergo CT examinations and are exposed to a CED of more than 100 mSv. At the same time, the survey enquires about and underlines radiologists' measures and radiology departments' strategies to limit such exposure. Over the period of 2015-2018, respondents reported that 0.5% (0-2.72%) of patients were exposed to a CED of ≥ 100 mSv from imaging procedures. The background radiation dose in Europe depends on the location, but it is around 2.5 mSv per year. It is obvious that patients with cancer, chronic diseases and trauma run the highest risk of having a high CED. However, even if the number of patients exposed to ≥ 100 mSv is relatively low, it is important to lower this number even further. Measures could consist in using procedures that do not necessitate radiation, using very low dose procedures, being very critical in requiring imaging procedures and increasing awareness about the issue. KEY POINTS: • A relatively low percentage of patients (0.5%) received a cumulative effective dose from CT computed tomography equal to or greater than 100 mSv, in Europe, most of them having an oncological disease. • There is a wide range in the number of patients who receive cumulative effective dose equal to or greater than 100 mSv (0-2.72%) and optimisation should be improved. • Increasing the awareness of referring physicians through encouraging local dialogue, concrete actions focused on optimisation and development of dose management systems is suggested.
Collapse
Affiliation(s)
- Guy Frija
- Université de Paris, 12 Rue de l'École de Médecine, 75006, Paris, France.
| | - John Damilakis
- School of Medicine, University of Crete, 71003, Iraklion, Greece
| | - Graciano Paulo
- ESTESC-Coimbra Health School, Medical Imaging and Radiotherapy Department, Instituto Politécnico de Coimbra, Rua 5 de Outubro, S. Martinho do Bispo, 3046-854, Coimbra, Portugal
| | - Reinhard Loose
- Institute of Medical Physics, Hospital Nuremberg, Prof.-Ernst-Nathan-Str. 1, 90419, Nuremberg, Germany
| | - Eliseo Vano
- Radiology Department, Complutense University, 28040, Madrid, Spain
| | | |
Collapse
|
7
|
Rehani MM, Nacouzi D. Higher patient doses through X-ray imaging procedures. Phys Med 2020; 79:80-86. [PMID: 33189060 DOI: 10.1016/j.ejmp.2020.10.017] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/30/2020] [Revised: 10/15/2020] [Accepted: 10/18/2020] [Indexed: 02/07/2023] Open
Abstract
Medical imaging using X-rays has been one of the most popular imaging modalities ever since the discovery of X-rays 125 years ago. With unquestionable benefits, concerns about radiation risks have frequently been raised. Computed tomography (CT) and fluoroscopic guided interventional procedures have the potential to impart higher radiation exposure to patients than radiographic examinations. Despite technological advances, there have been instances of increased doses per procedure mainly because of better diagnostic information in images. However, cumulative dose from multiple procedures is creating new concerns as effective doses >100 mSv are not uncommon. There is a need for action at all levels. Manufacturers must produce equipment that can provide a quality diagnostic image at substantially lesser dose and better implementation of optimization strategies by users. There is an urgent need for the industry to develop CT scanners with sub-mSv radiation dose, a goal that has been lingering. It appears that a new monochromatic X-ray source will lead to replacement of X-ray tubes all over the world in coming years and will lead to a drastic reduction in radiation doses. This innovation will impact all X-ray imaging and will help dose reduction. For interventional procedures, the likely employment of robotic systems in practice may drastically reduce radiation exposures to operators- but patient exposure will still remain an issue. Training needs always need to be emphasized and practiced.
Collapse
Affiliation(s)
| | - David Nacouzi
- Duke University Medical Center, Durham, NC 27708, USA
| |
Collapse
|
8
|
Abstract
Notwithstanding that 100 mSv is not a threshold for radiation effects, cumulative effective dose (CED) for patients of ≥100 mSv derived from recurrent imaging procedures with ionising radiation has been recently the topic of several publications. The International Commission on Radiological Protection has alerted on the problems to use effective dose for risk estimation in individual patients but has accepted to use this quantity for comparison the relative radiation risks between different imaging modalities. A new International Commission on Radiological Protection document on the use of effective dose (including medicine), is in preparation. Recently published data on the number of patients with CED ≥100 mSv ranged from 0.6 to 3.4% in CT and around 4% in interventional radiology. The challenges to manage the existing situation are summarised. The main aspects identified are: 1) New technology with dose reduction techniques. 2) Refinements in the application of the justification and optimisation for these groups of patients. 3) Patient dose management systems with alerts on the cumulative high doses. 4) Education on the proper use of cumulative effective dose for referrers and practitioners including information for patients. 5) Future research programmes in radiation biology and epidemiology may profit the patient dose data from the groups with high cumulative dose values.
Collapse
Affiliation(s)
- Eliseo Vano
- Department of Radiology, Emeritus Professor of Medical Physics. Complutense University, 28040 Madrid, Spain
| |
Collapse
|