1
|
Yang C, Ouyang L, Wang W, Chen B, Liu W, Yuan X, Luo Y, Cheng T, Yeung KWK, Liu X, Zhang X. Sodium butyrate-modified sulfonated polyetheretherketone modulates macrophage behavior and shows enhanced antibacterial and osteogenic functions during implant-associated infections. J Mater Chem B 2019; 7:5541-5553. [PMID: 31451811 DOI: 10.1039/c9tb01298b] [Citation(s) in RCA: 32] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Prevention of implant-associated infections and insufficient bone tissue integration is critical to exploit the immunomodulatory properties and antibacterial effects of implant materials, which have attracted considerable attention.
Collapse
|
2
|
Li J, Wen J, Li B, Li W, Qiao W, Shen J, Jin W, Jiang X, Yeung KWK, Chu PK. Valence State Manipulation of Cerium Oxide Nanoparticles on a Titanium Surface for Modulating Cell Fate and Bone Formation. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2018; 5:1700678. [PMID: 29610729 PMCID: PMC5827567 DOI: 10.1002/advs.201700678] [Citation(s) in RCA: 89] [Impact Index Per Article: 12.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/04/2017] [Revised: 10/19/2017] [Indexed: 05/19/2023]
Abstract
Understanding cell-biomaterial interactions is critical for the control of cell fate for tissue engineering and regenerative medicine. Here, cerium oxide nanoparticles (CeONPs) are applied at different Ce4+/Ce3+ ratios (i.e., 0.46, 1.23, and 3.23) to titanium substrate surfaces by magnetron sputtering and vacuum annealing. Evaluation of the cytotoxicity of the modified surface to cultured rat bone marrow mesenchymal stem cells (BMSCs) reveals that the cytocompatibility and cell proliferation are proportional to the increases in Ce4+/Ce3+ ratio on titanium surface. The bone formation capability induced by these surface modified titanium alloys is evaluated by implanting various CeONP samples into the intramedullary cavity of rat femur for 8 weeks. New bone formation adjacent to the implant shows a close relationship to the surface Ce4+/Ce3+ ratio; higher Ce4+/Ce3+ ratio achieves better osseointegration. The mechanism of this in vivo outcome is explored by culturing rat BMSCs and RAW264.7 murine macrophages on CeONP samples for different durations. The improvement in osteogenic differentiation capability of BMSCs is directly proportional to the increased Ce4+/Ce3+ ratio on the titanium surface. Increases in the Ce4+/Ce3+ ratio also elevate the polarization of the M2 phenotype of RAW264.7 murine macrophages, particularly with respect to the healing-associated M2 percentage and anti-inflammatory cytokine secretion. The manipulation of valence states of CeONPs appears to provide an effective modulation of the osteogenic capability of stem cells and the M2 polarization of macrophages, resulting in favorable outcomes of new bone formation and osseointegration.
Collapse
Affiliation(s)
- Jinhua Li
- Department of Orthopaedics and TraumatologyLi Ka Shing Faculty of MedicineThe University of Hong KongPokfulamHong Kong999077China
- Department of PhysicsDepartment of Materials Science and EngineeringCity University of Hong KongTat Chee AvenueKowloonHong Kong999077China
- Shenzhen Key Laboratory for Innovative Technology in Orthopaedic TraumaDepartment of Orthopaedics and TraumatologyThe University of Hong Kong‐Shenzhen HospitalShenzhen518053China
| | - Jin Wen
- Department of ProsthodonticsNinth People's Hospital affiliated to Shanghai Jiao Tong UniversitySchool of MedicineShanghai200011China
| | - Bin Li
- Department of OrthopedicsThe First Affiliated Hospital of Zhengzhou UniversityZhengzhou450052China
| | - Wan Li
- Department of PhysicsDepartment of Materials Science and EngineeringCity University of Hong KongTat Chee AvenueKowloonHong Kong999077China
| | - Wei Qiao
- Dental Materials ScienceApplied Oral SciencesFaculty of DentistryThe University of Hong KongHong Kong999077China
| | - Jie Shen
- Department of Orthopaedics and TraumatologyLi Ka Shing Faculty of MedicineThe University of Hong KongPokfulamHong Kong999077China
- Shenzhen Key Laboratory for Innovative Technology in Orthopaedic TraumaDepartment of Orthopaedics and TraumatologyThe University of Hong Kong‐Shenzhen HospitalShenzhen518053China
| | - Weihong Jin
- Department of PhysicsDepartment of Materials Science and EngineeringCity University of Hong KongTat Chee AvenueKowloonHong Kong999077China
| | - Xinquan Jiang
- Department of ProsthodonticsNinth People's Hospital affiliated to Shanghai Jiao Tong UniversitySchool of MedicineShanghai200011China
| | - Kelvin W. K. Yeung
- Department of Orthopaedics and TraumatologyLi Ka Shing Faculty of MedicineThe University of Hong KongPokfulamHong Kong999077China
- Shenzhen Key Laboratory for Innovative Technology in Orthopaedic TraumaDepartment of Orthopaedics and TraumatologyThe University of Hong Kong‐Shenzhen HospitalShenzhen518053China
| | - Paul K. Chu
- Department of PhysicsDepartment of Materials Science and EngineeringCity University of Hong KongTat Chee AvenueKowloonHong Kong999077China
| |
Collapse
|
3
|
Li J, Wang J, Wang D, Guo G, Yeung KWK, Zhang X, Liu X. Band Gap Engineering of Titania Film through Cobalt Regulation for Oxidative Damage of Bacterial Respiration and Viability. ACS APPLIED MATERIALS & INTERFACES 2017; 9:27475-27490. [PMID: 28748698 DOI: 10.1021/acsami.7b06867] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Biomaterial-related bacterial infections cause patient suffering, mortality, and extended periods of hospitalization and impose a substantial burden on medical systems. In this context, understanding the interactions between nanomaterials and bacteria is clinically significant. Herein, TiO2-based heterojunctions, including Co-TiO2, CoO-TiO2, and Co3O4-TiO2, were first designed by optimizing magnetron sputtering to establish a platform to explore the interactions between nanomaterials and bacteria. We found that the energy band bending and band gap narrowing were effectively promoted at the contact interface of the heterojunctions, which have the ability to induce abiotic reactive oxygen species formation. Using methicillin-resistant Staphylococcus aureus and Staphylococcus epidermidis, in vitro studies showed that the heterojunctions of Co-TiO2, CoO-TiO2, and especially Co3O4-TiO2 can effectively downregulate the expression levels of bacterial respiratory genes and cause oxidative damage to bacterial membrane respiration and viability. As a result, the surfaces of the heterojunctions possess a favorable antiadherent bacterial activity. Moreover, using an osteomyelitis model, the preclinical study on rats further confirmed the favorable anti-infection effect of the elaborately designed heterojunctions (especially Co3O4-TiO2). We hope this study can provide new insights into the surface antibacterial design of biomaterials using energy band engineering for both basic research and clinical needs. Meanwhile, this attempt may also contribute to expanding the biomedical applications of cobalt-based nanoparticles for the treatment of antibiotic-resistant infections.
Collapse
Affiliation(s)
- Jinhua Li
- State Key Laboratory of High Performance Ceramics and Superfine Microstructure, Shanghai Institute of Ceramics, Chinese Academy of Sciences , Shanghai 200050, China
- Department of Orthopaedics and Traumatology, Li Ka Shing Faculty of Medicine, The University of Hong Kong , Pokfulam, Hong Kong 999077, China
- Shenzhen Key Laboratory for Innovative Technology in Orthopaedic Trauma, The University of Hong Kong-Shenzhen Hospital , Shenzhen 518053, China
- University of Chinese Academy of Sciences , Beijing 100049, China
| | - Jiaxing Wang
- Department of Orthopaedics, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai Jiao Tong University , Shanghai 200233, China
| | - Donghui Wang
- Department of Orthopaedics, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai Jiao Tong University , Shanghai 200233, China
| | - Geyong Guo
- Department of Orthopaedics, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai Jiao Tong University , Shanghai 200233, China
| | - Kelvin W K Yeung
- Department of Orthopaedics and Traumatology, Li Ka Shing Faculty of Medicine, The University of Hong Kong , Pokfulam, Hong Kong 999077, China
- Shenzhen Key Laboratory for Innovative Technology in Orthopaedic Trauma, The University of Hong Kong-Shenzhen Hospital , Shenzhen 518053, China
| | - Xianlong Zhang
- Department of Orthopaedics, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai Jiao Tong University , Shanghai 200233, China
| | - Xuanyong Liu
- State Key Laboratory of High Performance Ceramics and Superfine Microstructure, Shanghai Institute of Ceramics, Chinese Academy of Sciences , Shanghai 200050, China
| |
Collapse
|