1
|
Wang X, Tian Q, Zhang B, Xu Y, Ji J, He Y, Huang J, Zhu M, Wang L, Chen S, Liu Z, Li G. Adhesive Carbon Paste Electrode for Convenient and Long-term Electrocardiogram Monitoring: A Pilot Study. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2023; 2023:1-4. [PMID: 38082924 DOI: 10.1109/embc40787.2023.10341094] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/18/2023]
Abstract
Long-term electrocardiogram (ECG) monitoring is an important and widely-used technique in the clinic that helps with the diagnosis of possible diseases that cannot be detected in a short time monitoring. However, the clinically used electrode needs conductive gel to reduce the impedance between the skin and the electrodes, which easily causes the possibility of allergy. Moreover, as the conductive gel becomes dry, the signal's quality will decrease accordingly. In this paper, we proposed a novel adhesive Carbon Paste Electrode (CPE) to achieve convenient and long-term ECG monitoring. By comparing the time-domain waveforms, the R-R peak intervals difference, and the Signal-to-Noise Ratio (SNR) of ECG with the traditional conductive gel-based electrode (Gel) in fixed and unfixed conditions, the performance of the proposed CPE was investigated. The results showed that the CPE could achieve similar ECG monitoring both in fixed and unfixed conditions. When on Day 2, the quality acquired by Gel began to decrease while CPE was still stable, which was obvious especially in unfixed condition. The R-R peak intervals showed that on Day 2, the Gel was unreliable with some abnormal points occurring. Besides, the results of SNR and average heart rate (AHR) also confirmed that the CPE could achieve similar results as Gel on Day 1 and outperformed Gel on Day 2. It is believed that the proposed CPE opens a window of high-quality long-term ECG monitoring with more convenience.
Collapse
|
2
|
Wang X, Tian Q, Pi Y, Xu Y, Zhu M, Wang X, Wang C, Wang C, Chen S, Liu Z, Li G. A Pilot Study on Long-term Physiological Signal Monitoring using Anhydrous Viscoplastic Electrodes. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2021; 2021:6767-6770. [PMID: 34892661 DOI: 10.1109/embc46164.2021.9630730] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Electrocardiography (ECG) and Electromyogram (EMG) are widely used to help physicians to diagnose various diseases. Besides, long-term physiological signals monitoring is of great significance for circumstances where certain diseases may not be observed in short-term monitoring. At present, wet electrodes are widely used in the clinic and are considered as a standard method to acquire physiological signals in high fidelity. However, current wet electrodes achieve high-quality signal acquisition by using conductive gel which will dry up as time elapses and finally leads to degradation of the signal quality. Therefore, an anhydrous viscoplastic electrode was proposed in this paper to solve the abovementioned problem. The proposed electrode, which is anhydrous and viscoplastic, enables high quality physiological signal acquisition with firm contact with the skin and it will not dry up within a long period of time. The results showed that the impedance of the proposed viscoplastic electrode could maintain relative stability after two days while that of the gel electrodes would increase significantly due to the gel dried up. Besides, the proposed electrode obtained physiological signals with high quality in both ECG and EMG tasks. After 24 hours of monitoring, the signal quality of the proposed electrode remained unchanged, indicated by the clearly recognizable time-domain signals. However, the signal waveform completely submerged in noise after the gel dried up. Moreover, the superior performance of the viscoplastic electrodes could be confirmed by the SNR difference between the two days, SNR further confirmed the superiority of the, with -2.03±2.10 dB and -3.40±8.27 dB for ECG and EMG respectively, and the SNR difference of gel electrodes were -7.59 ± 5.70 dB and -35.39±15.71 dB respectively. The proposed electrodes could be a great candidate for long-term physiological signal monitoring in risk management of healthcare.Clinical Relevance- The proposed electrode could achieve long-term physiological signals monitoring with high quality.
Collapse
|
3
|
Wang L, Chen G, Shu H, Cui X, Luo Z, Chang C, Zeng A, Zhang J, Fu Q. Facile covalent preparation of carbon nanotubes / amine-functionalized Fe 3O 4 nanocomposites for selective extraction of estradiol in pharmaceutical industry wastewater. J Chromatogr A 2021; 1638:461889. [PMID: 33485030 DOI: 10.1016/j.chroma.2021.461889] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2020] [Revised: 01/04/2021] [Accepted: 01/05/2021] [Indexed: 01/03/2023]
Abstract
As a typical steroid hormone drug, estradiol (E2) is also one of the most frequently detected endocrine disrupting chemicals (EDCs) in the aquatic environment. Herein, in response to the potential risk of E2 in steroid hormone pharmaceutical industry wastewater to human and wildlife, a novel carbon nanotubes / amine-functionalized Fe3O4 (CNTs/MNPs@NH2) nanocomposites with magnetic responsive have been developed for the enrichment and extraction of E2 in pharmaceutical industry wastewater, where amino-functionalized Fe3O4 magnetic nanoparticles (MNPs@NH2) were used as a magnetic source. The resultant CNTs/MNPs@NH2 possessed both the features of CNTs and desired magnetic property, enabling to rapidly recognize and separate E2 from pharmaceutical industry wastewater. Meanwhile, the CNTs/MNPs@NH2 had good binding behavior toward E2 with fast binding kinetics and high adsorption capacity, as well as exhibited satisfactory selectivity to steroidal estrogen compounds. Furthermore, the change of pH value of aqueous phase in adsorption solvent hardly affected the adsorption of E2 by CNTs/MNPs@NH2, and the adsorption capacity of E2 ranged from 19.9 to 17.2 mg g-1 in the pH range of 3.0 to 11.0, which is a latent advantage of the follow-up development method to detect E2 in pharmaceutical industry wastewater. As a result, the CNTs/MNPs@NH2 serving as a solid phase extraction medium were successfully applied to efficiently extract E2 from pharmaceutical industry wastewater. Therefore, the CNTs/MNPs@NH2 nanocomposites could be used as a potential adsorbent for removing steroidal estrogens from water. More importantly, the developed method would provide a promising solution for the monitoring and analysis of EDCs in pharmaceutical industry wastewater.
Collapse
Affiliation(s)
- Lu Wang
- Department of Pharmaceutical Analysis, School of Pharmacy, Xi'an Jiaotong University, Xi'an, 710061, China; Institute of Drug Safety and Monitoring, Academy of Pharmaceutical Science and Technology, Xi'an Jiaotong University, Xi'an, 710061, China
| | - Guoning Chen
- Department of Pharmaceutical Analysis, School of Pharmacy, Xi'an Jiaotong University, Xi'an, 710061, China; Institute of Drug Safety and Monitoring, Academy of Pharmaceutical Science and Technology, Xi'an Jiaotong University, Xi'an, 710061, China
| | - Hua Shu
- Department of Pharmaceutical Analysis, School of Pharmacy, Xi'an Jiaotong University, Xi'an, 710061, China; Institute of Drug Safety and Monitoring, Academy of Pharmaceutical Science and Technology, Xi'an Jiaotong University, Xi'an, 710061, China
| | - Xia Cui
- Department of Pharmaceutical Analysis, School of Pharmacy, Xi'an Jiaotong University, Xi'an, 710061, China; Institute of Drug Safety and Monitoring, Academy of Pharmaceutical Science and Technology, Xi'an Jiaotong University, Xi'an, 710061, China
| | - Zhimin Luo
- Department of Pharmaceutical Analysis, School of Pharmacy, Xi'an Jiaotong University, Xi'an, 710061, China; Institute of Drug Safety and Monitoring, Academy of Pharmaceutical Science and Technology, Xi'an Jiaotong University, Xi'an, 710061, China
| | - Chun Chang
- Department of Pharmaceutical Analysis, School of Pharmacy, Xi'an Jiaotong University, Xi'an, 710061, China; Institute of Drug Safety and Monitoring, Academy of Pharmaceutical Science and Technology, Xi'an Jiaotong University, Xi'an, 710061, China
| | - Aiguo Zeng
- Department of Pharmaceutical Analysis, School of Pharmacy, Xi'an Jiaotong University, Xi'an, 710061, China; Institute of Drug Safety and Monitoring, Academy of Pharmaceutical Science and Technology, Xi'an Jiaotong University, Xi'an, 710061, China
| | - Jia Zhang
- Shaanxi Hanjiang Pharmaceutical Group Co., Ltd, Hanzhong, 723000, China
| | - Qiang Fu
- Department of Pharmaceutical Analysis, School of Pharmacy, Xi'an Jiaotong University, Xi'an, 710061, China; Institute of Drug Safety and Monitoring, Academy of Pharmaceutical Science and Technology, Xi'an Jiaotong University, Xi'an, 710061, China.
| |
Collapse
|