1
|
Valdés Olmos RA, Collarino A, Rietbergen DDD, Pereira Arias-Bouda L, Giammarile F, Vidal-Sicart S. Setting-up a training programme for intraoperative molecular imaging and sentinel node mapping: how to teach? How to learn? Eur J Nucl Med Mol Imaging 2024; 51:2878-2892. [PMID: 38030743 DOI: 10.1007/s00259-023-06496-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2023] [Accepted: 10/26/2023] [Indexed: 12/01/2023]
Abstract
BACKGROUND The current expansion of image-guided surgery is closely related to the role played by radio-guided surgery in supporting the sentinel node (SN) procedure during more than three decades. The so-called triple approach (lymphoscintigraphy, gamma probe detection and blue dye) was not only essential in the seminal validation of the SN procedure but also a first collective learning effort based on skill transfer and outcome-related evaluation which laid the fundaments to delineate the field of intraoperative molecular imaging (IMI) based on a similar multimodality approach and multidisciplinary practice. METHODS These elements are also becoming valid in the current incorporation of SPECT/CT and PET/CT to existing and new protocols of IMI procedures and SN mapping concerning other clinical applications. On the other hand, there is a growing tendency to combine novel modern technologies in an allied role with gamma guidance in the operating room following the development of hybrid tracers and multimodal detection approaches. Against this background, learning initiatives are required for professionals working in this area. RESULTS This objective has led to a group of European practitioners with large experience in SN mapping and IMI applications to give shape to a programme made up out of specific learning modules aimed to be used as a conductive thread in peripherical or centralised training instances concerning the topic. CONCLUSION The presented work, written as a tutorial review, is placed in an available prior-art context and is primarily aimed at medical and paramedical practitioners as well as at hardware and software developers.
Collapse
Affiliation(s)
- Renato A Valdés Olmos
- Interventional Molecular Imaging Laboratory, Department of Radiology, Leiden University Medical Center, Albinusdreef 2, 2333 ZA, Leiden, The Netherlands.
- Department of Radiology, Section of Nuclear Medicine, Leiden University Medical Center, Albinusdreef 2, 2333 ZA, Leiden, The Netherlands.
| | - Angela Collarino
- Nuclear Medicine Unit, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy
| | - Daphne D D Rietbergen
- Interventional Molecular Imaging Laboratory, Department of Radiology, Leiden University Medical Center, Albinusdreef 2, 2333 ZA, Leiden, The Netherlands
- Department of Radiology, Section of Nuclear Medicine, Leiden University Medical Center, Albinusdreef 2, 2333 ZA, Leiden, The Netherlands
| | - Lenka Pereira Arias-Bouda
- Department of Radiology, Section of Nuclear Medicine, Leiden University Medical Center, Albinusdreef 2, 2333 ZA, Leiden, The Netherlands
| | - Francesco Giammarile
- Nuclear Medicine and Diagnostic Imaging Section, Division of Human Health, Department of Nuclear Sciences and Applications, International Atomic Energy Agency (IAEA), Vienna, Austria
| | - Sergi Vidal-Sicart
- Department of Nuclear Medicine, Hospital Clinic Barcelona, Barcelona, Catalonia, Spain
| |
Collapse
|
2
|
Babu B, Stoltz SA, Mittal A, Pawar S, Kolanthai E, Coathup M, Seal S. Inorganic Nanoparticles as Radiosensitizers for Cancer Treatment. NANOMATERIALS (BASEL, SWITZERLAND) 2023; 13:2873. [PMID: 37947718 PMCID: PMC10647410 DOI: 10.3390/nano13212873] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/07/2023] [Revised: 10/25/2023] [Accepted: 10/27/2023] [Indexed: 11/12/2023]
Abstract
Nanotechnology has expanded what can be achieved in our approach to cancer treatment. The ability to produce and engineer functional nanoparticle formulations to elicit higher incidences of tumor cell radiolysis has resulted in substantial improvements in cancer cell eradication while also permitting multi-modal biomedical functionalities. These radiosensitive nanomaterials utilize material characteristics, such as radio-blocking/absorbing high-Z atomic number elements, to mediate localized effects from therapeutic irradiation. These materials thereby allow subsequent scattered or emitted radiation to produce direct (e.g., damage to genetic materials) or indirect (e.g., protein oxidation, reactive oxygen species formation) damage to tumor cells. Using nanomaterials that activate under certain physiologic conditions, such as the tumor microenvironment, can selectively target tumor cells. These characteristics, combined with biological interactions that can target the tumor environment, allow for localized radio-sensitization while mitigating damage to healthy cells. This review explores the various nanomaterial formulations utilized in cancer radiosensitivity research. Emphasis on inorganic nanomaterials showcases the specific material characteristics that enable higher incidences of radiation while ensuring localized cancer targeting based on tumor microenvironment activation. The aim of this review is to guide future research in cancer radiosensitization using nanomaterial formulations and to detail common approaches to its treatment, as well as their relations to commonly implemented radiotherapy techniques.
Collapse
Affiliation(s)
- Balaashwin Babu
- Advanced Materials Processing and Analysis Center, Department of Materials Science and Engineering, University of Central Florida, Orlando, FL 32826, USA; (B.B.); (S.A.S.); (A.M.); (S.P.); (E.K.)
| | - Samantha Archer Stoltz
- Advanced Materials Processing and Analysis Center, Department of Materials Science and Engineering, University of Central Florida, Orlando, FL 32826, USA; (B.B.); (S.A.S.); (A.M.); (S.P.); (E.K.)
- Burnett School of Biomedical Sciences, College of Medicine, University of Central Florida, Orlando, FL 32827, USA
| | - Agastya Mittal
- Advanced Materials Processing and Analysis Center, Department of Materials Science and Engineering, University of Central Florida, Orlando, FL 32826, USA; (B.B.); (S.A.S.); (A.M.); (S.P.); (E.K.)
- Burnett School of Biomedical Sciences, College of Medicine, University of Central Florida, Orlando, FL 32827, USA
| | - Shreya Pawar
- Advanced Materials Processing and Analysis Center, Department of Materials Science and Engineering, University of Central Florida, Orlando, FL 32826, USA; (B.B.); (S.A.S.); (A.M.); (S.P.); (E.K.)
- Burnett School of Biomedical Sciences, College of Medicine, University of Central Florida, Orlando, FL 32827, USA
| | - Elayaraja Kolanthai
- Advanced Materials Processing and Analysis Center, Department of Materials Science and Engineering, University of Central Florida, Orlando, FL 32826, USA; (B.B.); (S.A.S.); (A.M.); (S.P.); (E.K.)
| | - Melanie Coathup
- Biionix Cluster, University of Central Florida, Orlando, FL 32827, USA;
- College of Medicine, University of Central Florida, Orlando, FL 32827, USA
| | - Sudipta Seal
- Advanced Materials Processing and Analysis Center, Department of Materials Science and Engineering, University of Central Florida, Orlando, FL 32826, USA; (B.B.); (S.A.S.); (A.M.); (S.P.); (E.K.)
- Burnett School of Biomedical Sciences, College of Medicine, University of Central Florida, Orlando, FL 32827, USA
- College of Medicine, University of Central Florida, Orlando, FL 32827, USA
- Nanoscience Technology Center, University of Central Florida, Orlando, FL, USA
| |
Collapse
|
3
|
Li X, Hsu JC, Son MH, Ha LN, Cai W. Cancer photodynamic therapy with chlorin e6-loaded, goat milk-derived extracellular vesicles: [ 18F]FDG lights up the way. Eur J Nucl Med Mol Imaging 2023; 50:247-250. [PMID: 36357594 PMCID: PMC9822859 DOI: 10.1007/s00259-022-06031-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Affiliation(s)
- Xiaoyan Li
- Departments of Radiology and Medical Physics, University of WI - Madison, Madison, WI, USA
| | - Jessica C Hsu
- Departments of Radiology and Medical Physics, University of WI - Madison, Madison, WI, USA
| | - Mai Hong Son
- Department of Nuclear Medicine, Hospital 108, Hanoi, Vietnam
| | - Le Ngoc Ha
- Department of Nuclear Medicine, Hospital 108, Hanoi, Vietnam
| | - Weibo Cai
- Departments of Radiology and Medical Physics, University of WI - Madison, Madison, WI, USA.
| |
Collapse
|
4
|
Guo H, Yu J, He X, Yi H, Hou Y, He X. Total Variation Constrained Graph Manifold Learning Strategy for Cerenkov Luminescence Tomography. OPTICS EXPRESS 2022; 30:1422-1441. [PMID: 35209303 DOI: 10.1364/oe.448250] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/10/2021] [Accepted: 12/19/2021] [Indexed: 06/14/2023]
Abstract
Harnessing the power and flexibility of radiolabeled molecules, Cerenkov luminescence tomography (CLT) provides a novel technique for non-invasive visualisation and quantification of viable tumour cells in a living organism. However, owing to the photon scattering effect and the ill-posed inverse problem, CLT still suffers from insufficient spatial resolution and shape recovery in various preclinical applications. In this study, we proposed a total variation constrained graph manifold learning (TV-GML) strategy for achieving accurate spatial location, dual-source resolution, and tumour morphology. TV-GML integrates the isotropic total variation term and dynamic graph Laplacian constraint to make a trade-off between edge preservation and piecewise smooth region reconstruction. Meanwhile, the tetrahedral mesh-Cartesian grid pair method based on the k-nearest neighbour, and the adaptive and composite Barzilai-Borwein method, were proposed to ensure global super linear convergence of the solution of TV-GML. The comparison results of both simulation experiments and in vivo experiments further indicated that TV-GML achieved superior reconstruction performance in terms of location accuracy, dual-source resolution, shape recovery capability, robustness, and in vivo practicability. Significance: We believe that this novel method will be beneficial to the application of CLT for quantitative analysis and morphological observation of various preclinical applications and facilitate the development of the theory of solving inverse problem.
Collapse
|
5
|
Darr C, Fragoso Costa P, Kesch C, Krafft U, Püllen L, Harke NN, Hess J, Szarvas T, Haubold J, Reis H, Fendler WP, Herrmann K, Radtke JP, Hadaschik BA, Tschirdewahn S. Prostate specific membrane antigen-radio guided surgery using Cerenkov luminescence imaging-utilization of a short-pass filter to reduce technical pitfalls. Transl Androl Urol 2021; 10:3972-3985. [PMID: 34804840 PMCID: PMC8575587 DOI: 10.21037/tau-20-1141] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2020] [Accepted: 12/07/2020] [Indexed: 12/27/2022] Open
Abstract
Background Intraoperative Cerenkov luminescence imaging (CLI) is a novel technique to assess surgical margins in patients undergoing nerve sparing radical prostatectomy (RP). Here, we analyze the efficacy of a 550-nm optical short-pass filter (OF) to improve its performance. Methods In this prospective single-center feasibility study ten patients with prostate cancer (PC) were included between December 2019 and April 2020, including three patients without tracer injection as a control group. After preoperative injection of 68-Ga-prostate-specific membrane antigen (PSMA)-11 followed by RP, CLI of the excised prostate and the incised index lesion was performed to visualize the primary tumor lesion. We compared the findings on intraoperative CLI to postoperative histopathology. Furthermore, CLI-intensities determined as tumor to background ratio (TBR) and contrast to noise ratio (CNR) were measured. Results Histopathology proved positive surgical margins (PSM) in 3 patients with corresponding findings in CLI. After magnetic resonance imaging (MRI)-informed incision above the index lesion 2 out of 3 prostates demonstrated elevated CLI signals with histopathological confirmation of PC cells. The use of the OF enabled a significant reduction of the area of the regions of interest from a median of 1.80 to 0.15 cm2 (reduction by 85%, P=0.005) leading to increased specificity. Signals due to PSMs were not suppressed by the 550-nm OF. The median TBR was reduced from 3.33 to 2.10. In all three patients of the control group elevated CLI intensities were detected at locations with diathermal energy deposition during surgery. After application of the 550-nm OF these were almost totally suppressed with a TBR of 1.10. Measurements of Cerenkov luminescence intensity with the 550-nm OF showed a significant Pearson's correlation of 0.82 between PSM and the elevated TBR (P=0.003) and a significant Pearson's correlation of 0.66 between PSM and elevated CNR (P=0.04). Measurements without the OF did not correlate significantly. Conclusions Intraoperative 68-Ga-PSMA CLI in PC is a tool that warrants further investigation to visualize PSM especially in intermediate and high-risk PC. Intraoperative CLI benefits from usage of a 550-nm OF to reduce false-positive signals.
Collapse
Affiliation(s)
- Christopher Darr
- Department of Urology, University Hospital Essen, Essen, Germany.,German Cancer Consortium (DKTK)-University Hospital Essen, Essen, Germany
| | - Pedro Fragoso Costa
- German Cancer Consortium (DKTK)-University Hospital Essen, Essen, Germany.,Department of Nuclear Medicine, University Hospital Essen, Essen, Germany
| | - Claudia Kesch
- Department of Urology, University Hospital Essen, Essen, Germany.,German Cancer Consortium (DKTK)-University Hospital Essen, Essen, Germany
| | - Ulrich Krafft
- Department of Urology, University Hospital Essen, Essen, Germany.,German Cancer Consortium (DKTK)-University Hospital Essen, Essen, Germany
| | - Lukas Püllen
- Department of Urology, University Hospital Essen, Essen, Germany.,German Cancer Consortium (DKTK)-University Hospital Essen, Essen, Germany
| | - Nina Natascha Harke
- Department of Urology, University Hospital Essen, Essen, Germany.,German Cancer Consortium (DKTK)-University Hospital Essen, Essen, Germany
| | - Jochen Hess
- Department of Urology, University Hospital Essen, Essen, Germany.,German Cancer Consortium (DKTK)-University Hospital Essen, Essen, Germany
| | - Tibor Szarvas
- Department of Urology, University Hospital Essen, Essen, Germany.,German Cancer Consortium (DKTK)-University Hospital Essen, Essen, Germany
| | - Johannes Haubold
- German Cancer Consortium (DKTK)-University Hospital Essen, Essen, Germany.,Institute of Diagnostics and Radiology, University Hospital Essen, Essen, Germany
| | - Henning Reis
- German Cancer Consortium (DKTK)-University Hospital Essen, Essen, Germany.,Institute of Pathology, University of Duisburg-Essen, Essen, Germany
| | - Wolfgang Peter Fendler
- German Cancer Consortium (DKTK)-University Hospital Essen, Essen, Germany.,Department of Nuclear Medicine, University Hospital Essen, Essen, Germany
| | - Ken Herrmann
- German Cancer Consortium (DKTK)-University Hospital Essen, Essen, Germany.,Department of Nuclear Medicine, University Hospital Essen, Essen, Germany
| | - Jan Philipp Radtke
- Department of Urology, University Hospital Essen, Essen, Germany.,German Cancer Consortium (DKTK)-University Hospital Essen, Essen, Germany
| | - Boris Alexander Hadaschik
- Department of Urology, University Hospital Essen, Essen, Germany.,German Cancer Consortium (DKTK)-University Hospital Essen, Essen, Germany
| | - Stephan Tschirdewahn
- Department of Urology, University Hospital Essen, Essen, Germany.,German Cancer Consortium (DKTK)-University Hospital Essen, Essen, Germany
| |
Collapse
|
6
|
Würnschimmel C, Wenzel M, Maurer T, Valdés Olmos RA, Vidal-Sicart S. Contemporary update of SPECT tracers and novelties in radioguided surgery: a perspective based on urology. THE QUARTERLY JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING : OFFICIAL PUBLICATION OF THE ITALIAN ASSOCIATION OF NUCLEAR MEDICINE (AIMN) [AND] THE INTERNATIONAL ASSOCIATION OF RADIOPHARMACOLOGY (IAR), [AND] SECTION OF THE SOCIETY OF RADIOPHARMACEUTICAL CHEMISTRY AND BIOLOGY 2021; 65:215-228. [PMID: 33829716 DOI: 10.23736/s1824-4785.21.03345-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
Recent technical advances and implementation of novel radiotracers have further increased the potential of radioguided surgery for a broad variety of malignancies. Indeed, the possibilities for future applications of novel radiotracers in diverse oncological strategies has become more promising than ever. This literature review aims to provide a contemporary update on a selected group of radiotracers and evaluates the usability of radioguided surgery and sentinel node procedures, focusing on most promising advances. For example, the impact of targeted radiotracers on prostate specific membrane antigen (PSMA), CD206 receptor-targeted agents (99mTc-tilmanocept), and hybrid tracers adding fluorescence to radioguidance (ICG-99mTc-nanocolloid) as well as targeting hypoxia-induced carbonic anhydrase IX (CAIX) will be covered. Furthermore, future outlooks on the implementation of gold nanoparticles (AuNP's), but also technical advances in improved radiotracer detection by hybrid gamma devices will be discussed.
Collapse
Affiliation(s)
- Christoph Würnschimmel
- Martini-Klinik Prostate Cancer Center, University Hospital of Hamburg-Eppendorf, Hamburg, Germany -
| | - Mike Wenzel
- Department of Urology, University Hospital of Frankfurt, Frankfurt, Germany
| | - Tobias Maurer
- Martini-Klinik Prostate Cancer Center, University Hospital of Hamburg-Eppendorf, Hamburg, Germany.,Department of Urology, University Hospital of Hamburg-Eppendorf, Hamburg, Germany
| | - Renato A Valdés Olmos
- Section of Nuclear Medicine, Department of Radiology, Interventional Molecular Imaging Laboratory, Leiden University Medical Center, Leiden, the Netherlands
| | - Sergi Vidal-Sicart
- Department of Nuclear Medicine, Clinic of Barcelona, Barcelona, Spain.,Institut d'Investigació Biomèdica August Pi i Sunyer (IDIBAPS), Barcelona, Spain
| |
Collapse
|
7
|
Lioret V, Bellaye PS, Arnould C, Collin B, Decréau RA. Dual Cherenkov Radiation-Induced Near-Infrared Luminescence Imaging and Photodynamic Therapy toward Tumor Resection. J Med Chem 2020; 63:9446-9456. [PMID: 32706253 DOI: 10.1021/acs.jmedchem.0c00625] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
Cherenkov radiation (CR), the blue light seen in nuclear reactors, is emitted by some radiopharmaceuticals. This study showed that (1) a portion of CR could be transferred in the region of the optical spectrum, where biological tissues are most transparent: as a result, upon radiance amplification in the near-infrared window, the detection of light could occur twice deeper in tissues than during classical Cherenkov luminescence imaging and (2) Cherenkov-photodynamic therapy (CR-PDT) on cells could be achieved under conditions mimicking unlimited depth using the CR-embarked light source, which is unlike standard PDT, where light penetration depth is limited in biological tissues. Both results are of utmost importance for simultaneous applications in tumor resection and post-resection treatment of remaining unresected margins, thanks to a molecular construct designed to raise its light collection efficiency (i.e., CR energy transfer) by conjugation with multiple CR-absorbing (water-soluble) antenna followed by intramolecular-FRET/TBET energy transfers.
Collapse
Affiliation(s)
- Vivian Lioret
- ICMUB Institute (Chemistry Department) Sciences Mirande, Université de Bourgogne Franche Comté, 9 Avenue Alain Savary, Dijon 21078, France
| | | | | | - Bertrand Collin
- Centre George François Leclerc, 1 rue du Professeur Marion, Dijon 21079, France
| | - Richard A Decréau
- ICMUB Institute (Chemistry Department) Sciences Mirande, Université de Bourgogne Franche Comté, 9 Avenue Alain Savary, Dijon 21078, France
| |
Collapse
|
8
|
Pashazadeh A, Friebe M. Radioguided surgery: physical principles and an update on technological developments. ACTA ACUST UNITED AC 2020; 65:1-10. [DOI: 10.1515/bmt-2018-0016] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2018] [Accepted: 01/08/2019] [Indexed: 01/10/2023]
Abstract
AbstractRadioguided surgery (RGS) is the use of radiation detection probes and handheld gamma cameras in surgery rooms to identify radioactively labeled lesions inside the body with an aim to improve surgical outcome. In today’s surgery, application of these devices is a well-established practice, which provides surgeons with real-time information to guide them to the site of a lesion. In recent years, there have been several major improvements in the technology and design of gamma probes and handheld gamma cameras, enhancing their applications in surgical practices. Handheld gamma cameras, for example, are now moving from single-modality to dual-modality scanners that add anatomical data to the physiologic data, and with that provide more clinical information of the tissue under study. Also, in the last decade, a radioguided surgical technique based on the Cerenkov radiation was introduced, with more improved sensitivity in identifying radioactively labeled lesions. Additionally, recent advances in hybrid tracers have led to more efficient detection of lesions labeled with these tracers. Besides, it seems that combining medical robotics and augmented reality technology with current radioguided surgical practices potentially will change the delivery and performance of RGS in the near future. The current paper aims to give an overview of the physics of RGS and summarizes recent advances in this field that have a potential to improve the application of radioguided surgical procedures in the management of cancer.
Collapse
Affiliation(s)
- Ali Pashazadeh
- Chair for Catheter Technologies and Image Guided Procedures, Otto-von-Guericke University, Magdeburg, Germany
- Department of Radiology and Nuclear Medicine, Medical Faculty, Otto-von-Guericke University, INKA, Building 53, Rotgerstrasse 9, 39104 Magdeburg, Germany
| | - Michael Friebe
- Chair for Catheter Technologies and Image Guided Procedures, Otto-von-Guericke University, Magdeburg, Germany
| |
Collapse
|
9
|
Pan Q, Zhang J, Li X, Zou Q, Zhang P, Luo Y, Jin Y. Construction of novel multifunctional luminescent nanoparticles based on DNA bridging and their inhibitory effect on tumor growth. RSC Adv 2019; 9:15042-15052. [PMID: 35516329 PMCID: PMC9064234 DOI: 10.1039/c9ra01381d] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2019] [Accepted: 05/07/2019] [Indexed: 01/10/2023] Open
Abstract
Cyclic RGD peptide was introduced onto the surface of silver nanoparticle (AgNP)-single strand DNA (ssDNA)-graphene quantum dots (GQDs) (ADG) after coating with a hybrid phospholipid material (ADG-DDPC) to be used for antitumor treatment. The Ag and ssDNA content was quantified. The morphology and properties of the nanoparticles were characterized by ultraviolet-visible absorption spectroscopy (UV-VIS), scanning electron microscopy (SEM), transmission electron microscopy (TEM), and atomic force microscopy (AFM). The etching effect of H2O2 on the AgNPs and the cleavage of DNA was observed. The cytotoxicity of the ADG-DDPC was investigated using the cell viability and LDH content. The cell uptake was evaluated by using the fluorescence recovery of the GQDs in the ADG-DDPC. The antitumor effects of ADG-DDPC were also evaluated. The content of the ssDNA was 15.3 μg mL-1. The content of the silver element in AgNPs was 3.75 μg mL-1 and 20.43 μg mL-1 in ADG-DDPC. ADG were distributed uniformly with the GQDs on the surface. After coating with hybrid phospholipid membranes containing DSPE-PEG2000-cRGD, ADG-DDPC was detected with an average size of 25.2 nm with a low IC50 of 209.68 ng mL-1 and showed LDH activity on HeLa cells. A better cellular uptake of ADG-DDPC was observed in HeLa cells, compared with cRGD-unmodified ADG nanoparticles (ADG-DDP), up to 6 and 12 h using the fluorescence recovery of GQDs as a measurement. Compared with ADG-DDP (3.6 mg of silver equivalent per kg body weight), ADG-DDPC at the same dose significantly halted 50.9% of tumor growth with little change to body weights when compared with a PTX Injection (10 mg kg-1). The novel nanoparticles, ADG-DDPC, could target tumor sites to exhibit multifunctional inhibition on tumor growth with little toxicity.
Collapse
Affiliation(s)
- Qiaobei Pan
- National Pharmaceutical Engineering Center for Solid Preparation in Chinese Herbal Medicine, Jiangxi University of Traditional Chinese Medicine Nanchang Jiangxi Province People's Republic of China +86-791-8711-9610
| | - Jing Zhang
- Key Laboratory of Modern Preparation of TCM, Ministry of Education, Jiangxi University of Traditional Chinese Medicine Nanchang Jiangxi Province People's Republic of China
| | - Xiang Li
- State Key Laboratory of Innovative Drug and Efficient Energy-Saving Pharmaceutical Equipment, Jiangxi University of Traditional Chinese Medicine Nanchang Jiangxi Province People's Republic of China +86-791-8711-9661
| | - Qian Zou
- State Key Laboratory of Innovative Drug and Efficient Energy-Saving Pharmaceutical Equipment, Jiangxi University of Traditional Chinese Medicine Nanchang Jiangxi Province People's Republic of China +86-791-8711-9661
| | - Peng Zhang
- Key Laboratory of Modern Preparation of TCM, Ministry of Education, Jiangxi University of Traditional Chinese Medicine Nanchang Jiangxi Province People's Republic of China
| | - Ying Luo
- Key Laboratory of Modern Preparation of TCM, Ministry of Education, Jiangxi University of Traditional Chinese Medicine Nanchang Jiangxi Province People's Republic of China
| | - Yi Jin
- National Pharmaceutical Engineering Center for Solid Preparation in Chinese Herbal Medicine, Jiangxi University of Traditional Chinese Medicine Nanchang Jiangxi Province People's Republic of China +86-791-8711-9610
| |
Collapse
|
10
|
Geng C, Ai Y, Tang X, Shu D, Gong C, Guan F. A Monte Carlo study of pinhole collimated Cerenkov luminescence imaging integrated with radionuclide treatment. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE 2019; 42:481-487. [PMID: 30830649 DOI: 10.1007/s13246-019-00744-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/18/2018] [Accepted: 02/26/2019] [Indexed: 12/20/2022]
Abstract
Cerenkov luminescence imaging (CLI) is an emerging optical imaging technique, which has been widely investigated for biological imaging. In this study, we proposed to integrate the CLI technique with the radionuclide treatment as a "see-and-treat" approach, and evaluated the performance of the pinhole collimator-based CLI technique. The detection of Cerenkov luminescence during radionuclide therapy was simulated using the Monte Carlo technique for breast cancer treatment as an example. Our results show that with the pinhole collimator-based configuration, the location, size and shape of the tumors can be clearly visualized on the Cerenkov luminescence images of the breast phantom. In addition, the CLI of multiple tumors can reflect the relative density of radioactivity among tumors, indicating that the intensity of Cerenkov luminescence is independent of the size and shape of a tumor. The current study has demonstrated the high-quality performance of the pinhole collimator-based CLI in breast tumor imaging for the "see-and-treat" multi-modality treatment.
Collapse
Affiliation(s)
- Changran Geng
- Department of Nuclear Science and Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing, 210016, China
- Collaborative Innovation Center of Radiation Medicine of Jiangsu Higher Education Institutions, Nanjing, 210016, China
| | - Yao Ai
- Department of Nuclear Science and Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing, 210016, China
- Collaborative Innovation Center of Radiation Medicine of Jiangsu Higher Education Institutions, Nanjing, 210016, China
| | - Xiaobin Tang
- Department of Nuclear Science and Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing, 210016, China.
- Collaborative Innovation Center of Radiation Medicine of Jiangsu Higher Education Institutions, Nanjing, 210016, China.
| | - Diyun Shu
- Department of Nuclear Science and Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing, 210016, China
- Collaborative Innovation Center of Radiation Medicine of Jiangsu Higher Education Institutions, Nanjing, 210016, China
| | - Chunhui Gong
- Department of Nuclear Science and Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing, 210016, China
- Collaborative Innovation Center of Radiation Medicine of Jiangsu Higher Education Institutions, Nanjing, 210016, China
| | - Fada Guan
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX, 77030, USA
| |
Collapse
|
11
|
Abstract
The electromagnetic spectrum contains different frequency bands useful for medical imaging and therapy. Short wavelengths (ionizing radiation) are commonly used for radiological and radionuclide imaging and for cancer radiation therapy. Intermediate wavelengths (optical radiation) are useful for more localized imaging and for photodynamic therapy (PDT). Finally, longer wavelengths are the basis for magnetic resonance imaging and for hyperthermia treatments. Recently, there has been a surge of interest for new biomedical methods that synergize optical and ionizing radiation by exploiting the ability of ionizing radiation to stimulate optical emissions. These physical phenomena, together known as radioluminescence, are being used for applications as diverse as radionuclide imaging, radiation therapy monitoring, phototherapy, and nanoparticle-based molecular imaging. This review provides a comprehensive treatment of the physics of radioluminescence and includes simple analytical models to estimate the luminescence yield of scintillators and nanoscintillators, Cherenkov radiation, air fluorescence, and biologically endogenous radioluminescence. Examples of methods that use radioluminescence for diagnostic or therapeutic applications are reviewed and analyzed in light of these quantitative physical models of radioluminescence.
Collapse
Affiliation(s)
- Justin Klein
- Department of Radiation Oncology, Stanford University, Stanford, CA 94305
| | - Conroy Sun
- College of Pharmacy, Oregon State University, Portland, OR 97201
| | - Guillem Pratx
- Department of Radiation Oncology, Stanford University, Stanford, CA 94305
| |
Collapse
|
12
|
Ciarrocchi E, Vanhove C, Descamps B, De Lombaerde S, Vandenberghe S, Belcari N. Performance evaluation of the LightPath imaging system for intra-operative Cerenkov luminescence imaging. Phys Med 2018; 52:122-128. [PMID: 30139600 DOI: 10.1016/j.ejmp.2018.07.005] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/26/2018] [Revised: 07/13/2018] [Accepted: 07/14/2018] [Indexed: 01/17/2023] Open
Abstract
The performances of an intra-operative optical imaging system for Cerenkov luminescence imaging of resected tumor specimens were evaluated with phantom studies. The spatial resolution, the linearity of the measured signal with the activity concentration and the minimum detectable activity concentration were considered. A high linearity was observed over a broad range of activity concentration (R2⩾0.99 down to ∼40 kBq/ml of 18F-FDG). For 18F-FDG activity distributions 2 mm deep in biological tissue, the measured detection limit was 8 kBq/ml and a spatial resolution of 2.5 mm was obtained. The detection limit of the imaging system is comparable with clinical activity concentrations in tumor specimens, and the spatial resolution is compatible with clinical requirements.
Collapse
Affiliation(s)
- Esther Ciarrocchi
- University of Pisa, Department of Physics, Largo Bruno Pontecorvo 3, Pisa 56127, Italy.
| | - Christian Vanhove
- University of Ghent, IBiTech-MEDISIP, C. Heymanslaan 10, Ghent B-9000, Belgium.
| | - Benedicte Descamps
- University of Ghent, IBiTech-MEDISIP, C. Heymanslaan 10, Ghent B-9000, Belgium.
| | - Stef De Lombaerde
- University of Ghent, Faculty of Pharmaceutical Sciences Laboratory of Radiopharmacy, Ottergemsesteenweg 460, Ghent B-9000, Belgium.
| | | | - Nicola Belcari
- University of Pisa, Department of Physics, Largo Bruno Pontecorvo 3, Pisa 56127, Italy.
| |
Collapse
|
13
|
Ai Y, Tang X, Shu D, Shao W, Gong C, Geng C, Zhang X, Yu H. Measurement of dose in radionuclide therapy by using Cerenkov radiation. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE 2017; 40:695-705. [PMID: 28808904 DOI: 10.1007/s13246-017-0579-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/24/2017] [Accepted: 08/06/2017] [Indexed: 12/23/2022]
Abstract
This work aims to determine the relationship between Cerenkov photon emission and radiation dose from internal radionuclide irradiation. Water and thyroid phantoms were used to simulate the distribution of Cerenkov photon emission and dose deposition through Monte Carlo method. The relationship between Cerenkov photon emission and dose deposition was quantitatively analyzed. A neck phantom was also used to verify Cerenkov photon detection for thyroid radionuclide therapy. Results show that Cerenkov photon emission and dose deposition exhibit the same distribution pattern in water phantom, and this relative distribution relationship also existed in the thyroid phantom. Moreover, Cerenkov photon emission exhibits a specific quantitative relation to dose deposition. For thyroid radionuclide therapy, only a part of Cerenkov photon produced by thyroid could penetrate the body for detection; therefore, the use of Cerenkov radiation for measurement of radionuclide therapy dose may be more suitable for superficial tumors. This study demonstrated that Cerenkov radiation has the potential to be used for measuring radiation dose for radionuclide therapy.
Collapse
Affiliation(s)
- Yao Ai
- Department of Nuclear Science and Engineering, Nanjing University of Aeronautics and Astronautics, 29 Yudao St., Nanjing, 210016, China
| | - Xiaobin Tang
- Department of Nuclear Science and Engineering, Nanjing University of Aeronautics and Astronautics, 29 Yudao St., Nanjing, 210016, China.
- Collaborative Innovation Center of Radiation Medicine of Jiangsu Higher Education Institutions, 29 Yudao St., Nanjing, 210016, China.
| | - Diyun Shu
- Department of Nuclear Science and Engineering, Nanjing University of Aeronautics and Astronautics, 29 Yudao St., Nanjing, 210016, China
| | - Wencheng Shao
- Department of Nuclear Science and Engineering, Nanjing University of Aeronautics and Astronautics, 29 Yudao St., Nanjing, 210016, China
| | - Chunhui Gong
- Department of Nuclear Science and Engineering, Nanjing University of Aeronautics and Astronautics, 29 Yudao St., Nanjing, 210016, China
| | - Changran Geng
- Department of Nuclear Science and Engineering, Nanjing University of Aeronautics and Astronautics, 29 Yudao St., Nanjing, 210016, China
- Collaborative Innovation Center of Radiation Medicine of Jiangsu Higher Education Institutions, 29 Yudao St., Nanjing, 210016, China
| | - Xudong Zhang
- Department of Nuclear Science and Engineering, Nanjing University of Aeronautics and Astronautics, 29 Yudao St., Nanjing, 210016, China
| | - Haiyan Yu
- Department of Nuclear Science and Engineering, Nanjing University of Aeronautics and Astronautics, 29 Yudao St., Nanjing, 210016, China
| |
Collapse
|