• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4608411)   Today's Articles (4837)   Subscriber (49375)
For: Schoenfeld AA, Thieben M, Harder D, Poppe B, Chofor N. Evaluation of water-mimicking solid phantom materials for use in HDR and LDR brachytherapy dosimetry. Phys Med Biol 2017;62:N561-N572. [PMID: 29072195 DOI: 10.1088/1361-6560/aa9636] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Number Cited by Other Article(s)
1
Colson D, Yalvac B, Weterings J, Verrijssen AS, van Haaren P, Bellezzo M, Berbée M, Van Limbergen EJ, Croce O, Verhaegen F, Reniers B. Dosimetry and Monte Carlo modelling of the Papillon+ contact X-ray brachytherapy device. Brachytherapy 2024:S1538-4721(24)00090-4. [PMID: 38969605 DOI: 10.1016/j.brachy.2024.06.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2024] [Revised: 05/31/2024] [Accepted: 06/06/2024] [Indexed: 07/07/2024]
2
A review of brachytherapy physical phantoms developed over the last 20 years: clinical purpose and future requirements. J Contemp Brachytherapy 2021;13:101-115. [PMID: 34025743 PMCID: PMC8117707 DOI: 10.5114/jcb.2021.103593] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2020] [Accepted: 11/13/2020] [Indexed: 12/04/2022]  Open
3
Majdaeen M, Dorri-Giv M, Olfat S, Ataei G, Abedi-Firouzjah R, Banaei A, Ranjbar S. Skin dose measurement and estimating the dosimetric effect of applicator misplacement in gynecological brachytherapy: A patient and phantom study. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY 2021;29:917-929. [PMID: 34180462 DOI: 10.3233/xst-210911] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
4
EGSnrc-based depth-dependent photon energy response and phantom scatter corrections for low-energy brachytherapy sources. Radiol Phys Technol 2020;13:256-267. [PMID: 32816228 DOI: 10.1007/s12194-020-00578-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2020] [Revised: 07/28/2020] [Accepted: 07/29/2020] [Indexed: 10/23/2022]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA