1
|
Firsova M, Treglia G, Sempoux C, Dromain C, Prior JO, Schaefer N, Boughdad S. Increased [ 68Ga]Ga-SST uptake in the uncinate pancreatic process in new digital PET/CT machine and potential association with clinical and histologic factors in NET patients. EJNMMI REPORTS 2024; 8:18. [PMID: 38910232 PMCID: PMC11194230 DOI: 10.1186/s41824-024-00203-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/06/2024] [Accepted: 04/10/2024] [Indexed: 06/25/2024]
Abstract
INTRODUCTION A physiological increase in the uptake of [68Ga]Ga-labeled somatostatin analogues ([68Ga]Ga-SST) PET tracers has been reported in the uncinate pancreatic process (UP) and might be even higher in latest generation of PET/CT scanners and might be falsely interpreted as NET. We aimed to investigate the uptake of UP in a large population of NET patients who underwent [68Ga]Ga-SST PET/CT with digital SiPM detectors. We also explored potential associations between UP uptake and various clinical, imaging, and pathological factors routinely assessed in NET patients. METHODS We analyzed all consecutive NET patients from July 2018 to June 2022 in this retrospective, single-center study. All patients underwent a [68Ga]Ga-SST PET/CT scan on a digital SiPM PET/CT scanner. On visual analysis, we distinguished between normal linear and homogenous UP uptake or abnormal if otherwise. We compared SUVmax/mean in patients with normal UP uptake to those with abnormal UP uptake with suspicious NET lesions on contrast-enhanced CT (ce-CT) and according to the site of the primary NET (pancreatic NET vs. other), patient gender (female vs. male) and tumor grade (grade 1-2 vs. 3) using a Mann-Whitney test. We also assessed the correlation between SUVmax/mean values in UP with patients' age, primary NET Ki-67 counting, and its SUVmax/mean, TLA and MTV values. RESULTS We included 131 NET patients with a total of 34 [68Ga]Ga-DOTATATE PET/CT and 113 [68Ga]Ga-DOTATOC PET/CT scans. An abnormal UP uptake was seen in 32 patients with 65.7% of suspicious NET lesion or extrinsic compression on morphological imaging. Normal UP uptake SUVmax/mean were measured in 115 [68Ga]Ga-SST scans (78.2%) with normal UP uptake and without suspicious lesion on morphological imaging. We found an average SUVmax of 12.3 ± 4.1 for [68Ga]Ga-DOTATATE and 19.8 ± 9.8 g/ml for [68Ga]Ga-DOTATOC, hence higher than those reported in the literature [SUVmax 5 ± 1.6 to 12.6 ± 2.2 g/ml] with significant difference with abnormal UP uptake and between both PET tracers (both p < 0.01). Significant results were a higher UP uptake on [68Ga]Ga-DOTATOC in male patients (p = 0.02) and significant associations between UP uptake on [68Ga]Ga-DOTATOC and SUVmax/mean of the primary tumor (ρ [0.337-0.363]; p [0.01-0.02]). CONCLUSION We confirmed a higher and very frequent UP uptake in latest SiPM-detector [68Ga]Ga-SST PET/CT with an even higher uptake in patients that had [68Ga]Ga-DOTATOC PET/CT. SUVmean/max were significantly higher in abnormal UP uptake but there were overlaps with UP SUV values for both [68Ga]Ga-SST and a correlation to morphological imaging is crucial. Besides, significant associations between UP uptake and SUVmean/max of the primary NET as well as patients' gender were seen in the larger cohort of [68Ga]Ga-DOTATOC patients suggesting that both physiological and pathological parameters could affect UP uptake.
Collapse
Affiliation(s)
- Maria Firsova
- Department of Nuclear Medicine and Molecular Imaging, Lausanne University Hospital, Rue du Bugnon 46, 1011, Lausanne, Switzerland
| | - Giorgio Treglia
- Department of Nuclear Medicine and Molecular Imaging, Lausanne University Hospital, Rue du Bugnon 46, 1011, Lausanne, Switzerland
- Faculty of Biology and Medicine, University of Lausanne, Lausanne, Switzerland
- Clinic of Nuclear Medicine, Imaging Institute of Southern Switzerland, Ente Ospedaliero Cantonale, Via A. Gallino 12, 6500, Bellinzona, Switzerland
- Academic Education, Research and Innovation Area, General Directorate, Ente Ospedaliero Cantonale, Bellinzona, Switzerland
- Faculty of Biomedical Sciences, Università della Svizzera Italiana, Lugano, Switzerland
| | - Christine Sempoux
- Faculty of Biology and Medicine, University of Lausanne, Lausanne, Switzerland
- Department of Pathology, Lausanne University Hospital, Lausanne, Switzerland
| | - Clarisse Dromain
- Faculty of Biology and Medicine, University of Lausanne, Lausanne, Switzerland
- Department of Radiology, Lausanne University Hospital, Lausanne, Switzerland
| | - John O Prior
- Department of Nuclear Medicine and Molecular Imaging, Lausanne University Hospital, Rue du Bugnon 46, 1011, Lausanne, Switzerland
- Faculty of Biology and Medicine, University of Lausanne, Lausanne, Switzerland
| | - Niklaus Schaefer
- Department of Nuclear Medicine and Molecular Imaging, Lausanne University Hospital, Rue du Bugnon 46, 1011, Lausanne, Switzerland
- Faculty of Biology and Medicine, University of Lausanne, Lausanne, Switzerland
| | - Sarah Boughdad
- Department of Nuclear Medicine and Molecular Imaging, Lausanne University Hospital, Rue du Bugnon 46, 1011, Lausanne, Switzerland.
| |
Collapse
|
2
|
Cox MC, Jurcka T, Arens AIJ, van Rijk MC, Kaanders JHAM, van den Bosch S. Quantitative and clinical implications of the EARL2 versus EARL1 [ 18F]FDG PET-CT performance standards in head and neck squamous cell carcinoma. EJNMMI Res 2023; 13:91. [PMID: 37878160 PMCID: PMC10600079 DOI: 10.1186/s13550-023-01042-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2023] [Accepted: 10/13/2023] [Indexed: 10/26/2023] Open
Abstract
BACKGROUND The EANM Research Ltd. (EARL) guidelines give recommendations for harmonization of [18F]FDG PET-CT image acquisition and reconstruction, aiming to ensure reproducibility of quantitative data between PET scanners. Recent technological advancements in PET-CT imaging resulted in an updated version of the EARL guidelines (EARL2). The aim of this study is to compare quantitative [18F]FDG uptake metrics of the primary tumor and lymph nodes in patients with head and neck squamous cell carcinoma (HNSCC) on EARL2 versus EARL1 reconstructed images and to describe clinical implications for nodal staging and treatment. METHODS Forty-nine consecutive patients with HNSCC were included. For all, both EARL1 and EARL2 images were reconstructed from a singular [18F]FDG PET-CT scan. Primary tumors and non-necrotic lymph nodes ≥ 5 mm were delineated on CT-scan. In the quantitative analysis, maximum standardized uptake values (SUVmax) and standardized uptake ratios (SURmax, i.e., SUVmax normalized to cervical spinal cord uptake) were calculated for all lesions on EARL1 and EARL2 reconstructions. Metabolic tumor volume (MTV) and total lesion glycolysis were compared between EARL1 and EARL2 using different segmentation methods (adaptive threshold; SUV2.5/3.5/4.5; SUR2.5/3.5/4.5; MAX40%/50%). In the qualitative analysis, each lymph node was scored independently by two nuclear medicine physicians on both EARL1 and EARL2 images on different occasions using a 4-point scale. RESULTS There was a significant increase in SUVmax (16.5%) and SURmax (9.6%) of primary tumor and lymph nodes on EARL2 versus EARL1 imaging (p < 0.001). The proportional difference of both SUVmax and SURmax between EARL2 and EARL1 decreased with increasing tumor volume (p < 0.001). Absolute differences in MTVs between both reconstructions were small (< 1.0 cm3), independent of the segmentation method. MTVs decreased on EARL2 using relative threshold methods (adaptive threshold; MAX40%/50%) and increased using static SUV or SUR thresholds. With visual scoring of lymph nodes 38% (11/29) of nodes with score 2 on EARL1 were upstaged to score 3 on EARL2, which resulted in an alteration of nodal stage in 18% (6/33) of the patients. CONCLUSIONS Using the EARL2 method for PET image reconstruction resulted in higher SUVmax and SURmax compared to EARL1, with nodal upstaging in a significant number of patients.
Collapse
Affiliation(s)
- Maurice C. Cox
- Department of Radiation Oncology, Radboud University Medical Center, 6525 GA Nijmegen, The Netherlands
| | - Tijn Jurcka
- Department of Radiation Oncology, Radboud University Medical Center, 6525 GA Nijmegen, The Netherlands
| | - Anne I. J. Arens
- Department of Radiology and Nuclear Medicine, Radboud University Medical Center, Nijmegen, The Netherlands
| | - Maartje C. van Rijk
- Department of Radiology and Nuclear Medicine, Radboud University Medical Center, Nijmegen, The Netherlands
| | | | - Sven van den Bosch
- Department of Radiation Oncology, Radboud University Medical Center, 6525 GA Nijmegen, The Netherlands
| |
Collapse
|
3
|
Sipilä O, Liukkonen J, Halme HL, Tolvanen T, Sohlberg A, Hakulinen M, Manninen AL, Tahvanainen K, Tunninen V, Ollikainen T, Kangasmaa T, Kangasmäki A, Vuorela J. Variability in PET image quality and quantification measured with a permanently filled 68Ge-phantom: a multi-center study. EJNMMI Phys 2023; 10:38. [PMID: 37322376 DOI: 10.1186/s40658-023-00551-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2022] [Accepted: 05/15/2023] [Indexed: 06/17/2023] Open
Abstract
BACKGROUND This study evaluated, as a snapshot, the variability in quantification and image quality (IQ) of the clinically utilized PET [18F]FDG whole-body protocols in Finland using a NEMA/IEC IQ phantom permanently filled with 68Ge. METHODS The phantom was imaged on 14 PET-CT scanners, including a variety of models from two major vendors. The variability of the recovery coefficients (RCmax, RCmean and RCpeak) of the hot spheres as well as percent background variability (PBV), coefficient of variation of the background (COVBG) and accuracy of corrections (AOC) were studied using images from clinical and standardized protocols with 20 repeated measurements. The ranges of the RCs were also compared to the limits of the EARL 18F standards 2 accreditation (EARL2). The impact of image noise on these parameters was studied using averaged images (AVIs). RESULTS The largest variability in RC values of the routine protocols was found for the RCmax with a range of 68% and with 10% intra-scanner variability, decreasing to 36% when excluding protocols with suspected cross-calibration failure or without point-spread-function (PSF) correction. The RC ranges of individual hot spheres in routine or standardized protocols or AVIs fulfilled the EARL2 ranges with two minor exceptions, but fulfilling the exact EARL2 limits for all hot spheres was variable. RCpeak was less dependent on averaging and reconstruction parameters than RCmax and RCmean. The PBV, COVBG and AOC varied between 2.3-11.8%, 9.6-17.8% and 4.8-32.0%, respectively, for the routine protocols. The RC ranges, PBV and COVBG were decreased when using AVIs. With AOC, when excluding routine protocols without PSF correction, the maximum value dropped to 15.5%. CONCLUSION The maximum variability of the RC values for the [18F]FDG whole-body protocols was about 60%. The RC ranges of properly cross-calibrated scanners with PSF correction fitted to the EARL2 RC ranges for individual sphere sizes, but fulfilling the exact RC limits would have needed further optimization. RCpeak was the most robust RC measure. Besides COVBG, also RCs and PVB were sensitive to image noise.
Collapse
Affiliation(s)
- O Sipilä
- HUS Diagnostic Center, Clinical Physiology and Nuclear Medicine, Helsinki University Hospital and University of Helsinki, P. O. Box 442, 00029, Helsinki, Finland.
| | - J Liukkonen
- Radiation and Nuclear Safety Authority, Vantaa, Finland
| | - H-L Halme
- HUS Diagnostic Center, Clinical Physiology and Nuclear Medicine, Helsinki University Hospital and University of Helsinki, P. O. Box 442, 00029, Helsinki, Finland
| | - T Tolvanen
- Turku PET Centre, Turku University Hospital, Turku, Finland
| | - A Sohlberg
- Department of Nuclear Medicine, Päijät-Häme Central Hospital, Lahti, Finland
| | - M Hakulinen
- Department of Clinical Physiology and Nuclear Medicine, Diagnostic Imaging Center, Kuopio University Hospital, Kuopio, Finland
- Department of Applied Physics, University of Eastern Finland, Kuopio, Finland
| | - A-L Manninen
- OYS Department of Nuclear Medicine and Radiology, Oulu University Hospital, Oulu, Finland
- Medical Research Center Oulu, Oulu University Hospital and University of Oulu, Oulu, Finland
| | - K Tahvanainen
- HUS Diagnostic Center, Clinical Physiology and Nuclear Medicine, Helsinki University Hospital and University of Helsinki, P. O. Box 442, 00029, Helsinki, Finland
| | - V Tunninen
- Department of Clinical Physiology and Nuclear Medicine, Satakunta Central Hospital, Pori, Finland
| | - T Ollikainen
- Clinical Physiology and Neurophysiology, North Karelia Central Hospital, Joensuu, Finland
| | - T Kangasmaa
- Department of Clinical Physiology and Nuclear Medicine, Vaasa Central Hospital, Wellbeing Services County of Ostrobothnia, Vaasa, Finland
| | - A Kangasmäki
- Department of Imaging and Radiotherapy, Docrates Cancer Center, Helsinki, Finland
| | - J Vuorela
- Clinical Physiology and Nuclear Medicine, Central Finland Health Care District, Jyväskylä, Finland
| |
Collapse
|
4
|
Juengling FD, Wuest F, Kalra S, Agosta F, Schirrmacher R, Thiel A, Thaiss W, Müller HP, Kassubek J. Simultaneous PET/MRI: The future gold standard for characterizing motor neuron disease-A clinico-radiological and neuroscientific perspective. Front Neurol 2022; 13:890425. [PMID: 36061999 PMCID: PMC9428135 DOI: 10.3389/fneur.2022.890425] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2022] [Accepted: 07/20/2022] [Indexed: 01/18/2023] Open
Abstract
Neuroimaging assessment of motor neuron disease has turned into a cornerstone of its clinical workup. Amyotrophic lateral sclerosis (ALS), as a paradigmatic motor neuron disease, has been extensively studied by advanced neuroimaging methods, including molecular imaging by MRI and PET, furthering finer and more specific details of the cascade of ALS neurodegeneration and symptoms, facilitated by multicentric studies implementing novel methodologies. With an increase in multimodal neuroimaging data on ALS and an exponential improvement in neuroimaging technology, the need for harmonization of protocols and integration of their respective findings into a consistent model becomes mandatory. Integration of multimodal data into a model of a continuing cascade of functional loss also calls for the best attempt to correlate the different molecular imaging measurements as performed at the shortest inter-modality time intervals possible. As outlined in this perspective article, simultaneous PET/MRI, nowadays available at many neuroimaging research sites, offers the perspective of a one-stop shop for reproducible imaging biomarkers on neuronal damage and has the potential to become the new gold standard for characterizing motor neuron disease from the clinico-radiological and neuroscientific perspectives.
Collapse
Affiliation(s)
- Freimut D. Juengling
- Division of Oncologic Imaging, University of Alberta, Edmonton, AB, Canada
- Neuroscience and Mental Health Institute, University of Alberta, Edmonton, AB, Canada
- Faculty of Medicine, University Bern, Bern, Switzerland
| | - Frank Wuest
- Division of Oncologic Imaging, University of Alberta, Edmonton, AB, Canada
| | - Sanjay Kalra
- Neuroscience and Mental Health Institute, University of Alberta, Edmonton, AB, Canada
- Department of Neurology, University of Alberta, Edmonton, AB, Canada
| | - Federica Agosta
- Division of Neuroscience, San Raffaele Scientific Institute, University Vita Salute San Raffaele, Milan, Italy
| | - Ralf Schirrmacher
- Division of Oncologic Imaging, University of Alberta, Edmonton, AB, Canada
- Medical Isotope and Cyclotron Facility, University of Alberta, Edmonton, AB, Canada
| | - Alexander Thiel
- Lady Davis Institute for Medical Research, Department of Neurology and Neurosurgery, McGill University, Montreal, QC, Canada
| | - Wolfgang Thaiss
- Department of Nuclear Medicine, University of Ulm Medical Center, Ulm, Germany
- Department of Diagnostic and Interventional Radiology, University of Ulm Medical Center, Ulm, Germany
| | - Hans-Peter Müller
- Department of Neurology, Ulm University Medical Center, Ulm, Germany
| | - Jan Kassubek
- Department of Neurology, Ulm University Medical Center, Ulm, Germany
| |
Collapse
|
5
|
Boughdad S, Meyer M, Prior JO, Fernandes V, Allenbach G, Kamani C, Jreige M, Albano D, Bertagna F, Nicod-Lalonde M, Schaefer N, Treglia G. Prevalence of physiological uptake in the pancreas on somatostatin receptor-based PET/CT: a systematic review and a meta-analysis. Clin Transl Imaging 2021. [DOI: 10.1007/s40336-021-00432-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
Abstract
Background
Physiological focal radiopharmaceutical uptake in the head and uncinate process of the pancreas may be seen on somatostatin receptor-based PET/CT and might lead to false-positive results for neuroendocrine tumours (NETs). We aimed to perform a systematic review and a meta-analysis about the prevalence of this finding.
Methods
We performed a comprehensive computer literature search across several databases until July 2020. Pooled prevalence of physiological focal uptake on somatostatin receptor-based PET/CT in the pancreas was calculated on a per-examination-based analysis and 95% confidence interval values (95% CI) were reported.
Results
Six studies (684 patients and 829 PET/CT scans) were included. The pooled prevalence of physiological uptake in the head and uncinate process of the pancreas on somatostatin receptor-based PET/CT imaging was 34% (95% CI 19.5–48.7%) with average SUVmax values ranging from 5 to 12.6. Heterogeneity was seen across the selected studies.
Conclusions
High radiopharmaceutical uptake in the head and uncinate process of the pancreas is frequent at somatostatin receptor-based PET/CT and it should be recognized by nuclear medicine physicians to prevent unnecessary additional investigations. In addition, next generation PET/CT tomographs might increase the prevalence of this finding.
Collapse
|
6
|
Lowe G, Spottiswoode B, Declerck J, Sullivan K, Sharif MS, Wong WL, Sanghera B. Positron emission tomography PET/CT harmonisation study of different clinical PET/CT scanners using commercially available software. BJR Open 2020; 2:20190035. [PMID: 33178963 PMCID: PMC7594895 DOI: 10.1259/bjro.20190035] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2019] [Revised: 04/30/2020] [Accepted: 05/04/2020] [Indexed: 11/06/2022] Open
Abstract
Objectives: Harmonisation is the process whereby standardised uptake values from different scanners can be made comparable. This PET/CT pilot study aimed to evaluate the effectiveness of harmonisation of a modern scanner with image reconstruction incorporating resolution recovery (RR) with another vendor older scanner operated in two-dimensional (2D) mode, and for both against a European standard (EARL). The vendor-proprietary software EQ•PET was used, which achieves harmonisation with a Gaussian smoothing. A substudy investigated effect of RR on harmonisation. Methods: Phantom studies on each scanner were performed to optimise the smoothing parameters required to achieve successful harmonisation. 80 patients were retrospectively selected; half were imaged on each scanner. As proof of principle, a cohort of 10 patients was selected from the modern scanner subjects to study the effects of RR on harmonisation. Results: Before harmonisation, the modern scanner without RR adhered to EARL specification. Using the phantom data, filters were derived for optimal harmonisation between scanners and with and without RR as applicable, to the EARL standard. The 80-patient cohort did not reveal any statistically significant differences. In the 10-patient cohort SUVmax for RR > no RR irrespective of harmonisation but differences lacked statistical significance (one-way ANOVA F(3.36) = 0.37, p = 0.78). Bland-Altman analysis showed that harmonisation reduced the SUVmax ratio between RR and no RR to 1.07 (95% CI 0.96–1.18) with no outliers. Conclusions: EQ•PET successfully enabled harmonisation between modern and older scanners and against the EARL standard. Harmonisation reduces SUVmax and dependence on the use of RR in the modern scanner. Advances in knowledge: EQ•PET is feasible to harmonise different PET/CT scanners and reduces the effect of RR on SUVmax.
Collapse
Affiliation(s)
- Gerry Lowe
- Cancer Centre, Mount Vernon Hospital, London, UK
| | | | | | - Keith Sullivan
- Health Research Methods Unit, University of Hertfordshire, Hertfordshire, UK
| | - Mhd Saeed Sharif
- School of Arch., Comp. and Eng., University of East London, London, UK
| | - Wai-Lup Wong
- Paul Strickland Scanner Centre, Mount Vernon Hospital, London, UK
| | - Bal Sanghera
- Paul Strickland Scanner Centre, Mount Vernon Hospital, London, UK
| |
Collapse
|
7
|
How Often Do We Fail to Classify the Treatment Response with [18F]FDG PET/CT Acquired on Different Scanners? Data from Clinical Oncological Practice Using an Automatic Tool for SUV Harmonization. Mol Imaging Biol 2019; 21:1210-1219. [DOI: 10.1007/s11307-019-01342-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
|