Huang Q, Zhou Y, Pan L, Chen Y, Wang N, Li K, Bai J, Ji X. Experimental Evaluation of an Ultrasound-Guided High-Intensity-Focused Ultrasound Probe for Sonication of Artery. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2024; 43:2357-2373. [PMID: 39240034 DOI: 10.1002/jum.16571] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/09/2024] [Revised: 07/23/2024] [Accepted: 08/24/2024] [Indexed: 09/07/2024]
Abstract
OBJECTIVES This study aimed to develop an ultrasound-guided high-intensity-focused ultrasound (USgHIFU) probe for arterial sonication and to evaluate vascular contraction. METHODS The USgHIFU probe comprised two confocal spherical transducers for sonication and a US color Doppler flow imaging probe for guidance. A vessel-mimicking phantom was sonicated in two directions. In the vascular radial direction, an isolated rabbit aorta embedded in ex vivo pork liver was sonicated at different acoustic powers (245 and 519 W), flow rates (25, 30, and 50 mL/minute), and sonication energies (519, 980, and 1038 J). Changes in the postsonication vessels were evaluated using US imaging, microscopic observation, and histopathological analysis. RESULTS Beam focusing along the vascular radial direction caused significant deformation of both tube walls (n = 4), whereas focusing along the axial direction only affected the contraction of the anterior wall (n = 4). The contraction index (Dc) of the vessel sonicated at 245 W and 980 J was 56.2 ± 9.7% (n = 12) with 25 mL/minute. The Dc of the vessel sonicated at 519 W and 1038 J was 56.5 ± 7.8% (n = 17). The Dc of the vessel sonicated at 519 J total energy was 18.3 ± 5.1% (n = 12). CONCLUSION The developed USgHIFU probe induced greater vascular contractions by covering a larger area of the vessel wall in the radial direction. Sonication energy affects vascular contraction through temperature elevation of the vessel wall. When the acoustic power was high, an increase in acoustic power, even with comparable sonication energy, did not result in greater vessel contraction.
Collapse
Affiliation(s)
- Qianwen Huang
- Biomedical Instrument Institute, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Yun Zhou
- Department of Ultrasonography, International Peace Maternity and Child Health Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Lei Pan
- Department of Pathology, International Peace Maternity and Child Health Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Yini Chen
- Biomedical Instrument Institute, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
- Department of Ultrasonography, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Nianou Wang
- Biomedical Instrument Institute, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Ke Li
- College of Pharmaceutical Sciences, Zhejiang University, Hangzhou, China
| | - Jingfeng Bai
- Biomedical Instrument Institute, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
- Shanghai Med-X Engineering Research Center, Shanghai Jiao Tong University, Shanghai, China
| | - Xiang Ji
- Biomedical Instrument Institute, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
- Shanghai Med-X Engineering Research Center, Shanghai Jiao Tong University, Shanghai, China
| |
Collapse
|
2
|
Casoni P, Bissacco D, Pizzamiglio M, Nanni E, Serra L. Action of high intensity focused ultrasound (HIFU) ablation on the venous wall: Histopathological analysis, insights, and perspectives. Phlebology 2024:2683555241297215. [PMID: 39471838 DOI: 10.1177/02683555241297215] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2024]
Abstract
In the medical field, ultrasound is commonly used for diagnostic imaging due to its ability to provide real-time images. However, High-Intensity Focused Ultrasound (HIFU) is also used for other clinical purposes, such as thermal tissue ablation. In the case of varicose veins, the potential role and benefits of HIFU have been known for a long time despite in-vivo results have mostly been preliminary and experimental, particularly regarding its effect on venous wall. The aim of this brief report is to describe how HIFU acts on venous wall in human incompetent great saphenous veins.
Collapse
Affiliation(s)
| | - Daniele Bissacco
- Department of Clinical Sciences and Community Health, University of Milan, Milan, Italy
| | | | | | - Luigi Serra
- Pathology Unit, Morgagni-Pierantoni Hospital, Forlì, Italy
| |
Collapse
|
3
|
Huang Q, Zhou Y, Li K, Pan L, Liu Y, Bai J, Ji X. Parameter effects on arterial vessel sonicated by high-intensity focused ultrasound: an ex vivo vascular phantom study. Phys Med Biol 2022; 67. [DOI: 10.1088/1361-6560/ac910c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2022] [Accepted: 09/09/2022] [Indexed: 11/11/2022]
Abstract
Abstract
Objective. This study is aimed to explore the effects of vascular and sonication parameters on ex vivo vessel sonicated by high-intensity focused ultrasound. Approach. The vascular phantom embedding the polyolefin tube or ex vivo vessel was sonicated. The vascular phantom with 1.6 and 3.2 mm tubes was sonicated at three acoustic powers (2.0, 3.5, 5.3 W). The occlusion level of post-sonication tubes was evaluated using ultrasound imaging. The vascular phantom with the ex vivo abdominal aorta of rabbit for three flow rates (0, 5, 10 cm s−1) was sonicated at two acoustic powers (3.5 and 5.3 W). Different distances between focus and posterior wall (2, 4, 6 mm) and cooling times (0 and 10 s) were also evaluated. The diameter of the sonicated vessel was measured by B-mode imaging and microscopic photography. Histological examination was performed for the sonicated vessels. Main results. For the 5 cm s−1 flow rate, the contraction index of vascular diameter (Dc) with 5.3 W and 10 s cooling time at 2 mm distance was 39 ± 9% (n = 9). With the same parameters except for 0 cm s−1 flow rate, the Dc was increased to 45 ± 7% (n = 4). At 3.5 W, the Dc with 5 cm s−1 flow rate was 23 ± 15% (n = 4). The distance and cooling time influenced the lesion along the vessel wall. Significance. This study has demonstrated the flow rate and acoustic power have the great impact on the vessel contraction. Besides, the larger lesion covering the vessel wall would promote the vessel contraction. And the in vivo validation is required in the future study.
Collapse
|
4
|
Ditac G, Bessière F, Lafon C. Therapeutic ultrasound applications in cardiovascular diseases: a review. Ing Rech Biomed 2022. [DOI: 10.1016/j.irbm.2022.07.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
5
|
Zhou Y, Ji X, Niu J, Sun T, Qian Z, Li Y, Yuan J, Fan Q, Huang Q, Bai J, Wang Y. Ultrasound-Guided High-Intensity Focused Ultrasound for Devascularization of Uterine Fibroid: A Feasibility Study. ULTRASOUND IN MEDICINE & BIOLOGY 2021; 47:2622-2635. [PMID: 34147312 DOI: 10.1016/j.ultrasmedbio.2021.05.012] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/01/2020] [Revised: 05/05/2021] [Accepted: 05/09/2021] [Indexed: 06/12/2023]
Abstract
This study aimed to establish the feasibility of ultrasound-guided high-intensity focused ultrasound (USgHIFU) for devascularization of uterine fibroids. Ultrasound color Doppler flow imaging (CDFI) and B-mode imaging were used to target fibroid vascularity. The vessels were covered and ablated by high-intensity focused ultrasound spots. In this study, 42 fibroids with a volume of 66.98 ± 4.00 cm3 were treated. No blood flow was detected by post-treatment CDFI in 40 fibroids. The 6-mo non-perfusion volume rate was 75.23% ± 34.77% (n = 40). The mean shrinkage in fibroid volume was 38.20% and 43.89%, respectively, at 1 and 6 mo after treatment (p < 0.001). The uterine fibroid symptom and quality of life scores were reduced by 9.43% at 1 mo and 26.66% at 6-mo after treatment (p < 0.001). No serious adverse event was observed. This study demonstrates the feasibility of USgHIFU-induced fibroid devascularization, and more studies are required for the evaluation of safety and efficacy.
Collapse
Affiliation(s)
- Yun Zhou
- Department of Ultrasonography, International Peace Maternity and Child Health Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Xiang Ji
- Biomedical Instrument Institute, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China; Shanghai Med-X Engineering Research Center, Shanghai Jiao Tong University, Shanghai, China
| | - Jianmei Niu
- Department of Ultrasonography, International Peace Maternity and Child Health Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Taotao Sun
- Department of Radiology, International Peace Maternity and Child Health Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Zhaoxia Qian
- Department of Radiology, International Peace Maternity and Child Health Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Yuhong Li
- Department of Gynecologic Oncology, International Peace Maternity and Child Health Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Jiangjing Yuan
- Department of Gynecologic Oncology, International Peace Maternity and Child Health Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Qiong Fan
- Department of Gynecologic Oncology, International Peace Maternity and Child Health Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Qianwen Huang
- Biomedical Instrument Institute, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Jingfeng Bai
- Biomedical Instrument Institute, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China; Shanghai Med-X Engineering Research Center, Shanghai Jiao Tong University, Shanghai, China
| | - Yudong Wang
- Department of Gynecologic Oncology, International Peace Maternity and Child Health Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China.
| |
Collapse
|
6
|
Barnat N, Grisey A, Gerold B, Yon S, Anquez J, Aubry JF. Vein wall shrinkage induced by thermal coagulation with high-intensity-focused ultrasound: numerical modeling and in vivo experiments in sheep. Int J Hyperthermia 2021; 37:1238-1247. [PMID: 33164625 DOI: 10.1080/02656736.2020.1834626] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022] Open
Abstract
BACKGROUND Varicose veins are a common disease that may significantly affect quality of life. Different approaches are currently used in clinical practice to treat this pathology. MATERIALS AND METHODS In thermal therapy (radiofrequency or laser therapy), the vein is directly heated to a high temperature to induce vein wall coagulation, and the heat induces denaturation of the intramural collagen, which results macroscopically in vein shrinkage. Thermal vein shrinkage is a physical indicator of the efficiency of endovenous treatment. High-intensity focused ultrasound (HIFU) is a noninvasive technique that can thermally coagulate vein walls and induce vein shrinkage. In this study, we evaluated the vein shrinkage induced in vivo by extracorporeal HIFU ablation of sheep veins: six lateral saphenous veins (3.4mm mean diameter) were sonicated for 8 s with 3MHz continuous waves. Ultrasound imaging was performed before and immediately post-HIFU to quantify the HIFU-induced shrinkage. RESULTS Luminal constriction was observed in 100% (6/6) of the treated veins. The immediate findings showed a mean diameter constriction of 53%. The experimental HIFU-induced shrinkage data were used to validate a numerical model developed to predict the thermally induced vein contraction during HIFU treatment. CONCLUSIONS This model is based on the use of the k-wave library and published contraction rates of vessels immersed in hot water baths. The simulation results agreed well with those of in vivo experiments, showing a mean percent difference of 5%. The numerical model could thus be a valuable tool for optimizing ultrasound parameters as functions of the vein diameter, and future clinical trials are anticipated.
Collapse
Affiliation(s)
- Nesrine Barnat
- Physics for Medicine Paris, Inserm, ESPCI Paris, CNRS, PSL Research University, Paris, France.,Theraclion, Malakoff, France
| | | | | | | | | | - Jean-François Aubry
- Physics for Medicine Paris, Inserm, ESPCI Paris, CNRS, PSL Research University, Paris, France
| |
Collapse
|
7
|
Pahk KJ. Evidence of the formation of the shock scattering induced violent cavitation cluster during boiling histotripsy insonation: A numerical case study. ACTA ACUST UNITED AC 2021. [DOI: 10.1088/1742-6596/1761/1/012006] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
8
|
Obermayer A, Aubry JF, Barnat N. Extracorporeal Treatment with High Intensity Focused Ultrasound of an Incompetent Perforating Vein in a Patient with Active Venous Ulcers. EJVES Vasc Forum 2020; 50:1-5. [PMID: 33377135 PMCID: PMC7758513 DOI: 10.1016/j.ejvsvf.2020.11.005] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2020] [Revised: 11/18/2020] [Accepted: 11/26/2020] [Indexed: 11/30/2022] Open
Abstract
Introduction Endovenous techniques such as ultrasound guided foam sclerotherapy, thermal methods, or glues are generally recommended to occlude incompetent veins. However, these methods can be technically challenging and risky for patients with severe atrophic skin disorders like lipodermatosclerosis or atrophie blanche. High intensity focused ultrasound (HIFU), which has been shown to coagulate and occlude veins successfully, may offer an alternative method. This case report details ultrasound guided HIFU to occlude non-invasively a refluxing perforator vein causing active ulcers. Report A 95 year old man presented to the Institute for Functional Phlebology (Melk, Austria) with painful recurrent ulcers in his left medial calf. His limb was scored C2,3,4a, b,6, Ep, Ap, Pr,18 according to the Clinical, Etiology, Anatomic, Pathophysiology (CEAP) classification. Lower limb ultrasound revealed a refluxing posterior tibial perforating vein, measuring 2.7 mm in diameter at the level of the fascia. Extracorporeal HIFU pulses were delivered to this vein with the Sonovein device (Theraclion, Malakoff, France). Sonication was applied for eight seconds at a mean acoustic power of 80 W. The patient was followed up for three months post-treatment and occlusion was evaluated by duplex ultrasound. There were no complications during treatment or follow up. Three months after the treatment, reflux was abolished and the two initially active ulcers had healed. Discussion Although this is an early report, this study shows that HIFU can be successful in ablation of incompetent perforator veins in the treatment of venous leg ulcers. Endovenous methods are not suited to all patients with severe skin disorders. High intensity focused ultrasound can treat venous leg disorders non-invasively. Treatments have been performed on a refluxing perforator vein causing active ulcers. Short-term results showed that this technique is as good as other thermal therapies.
Collapse
Affiliation(s)
- Alfred Obermayer
- Institute for Functional Phlebosurgery, Karl Landsteiner Society, Melk, Austria
| | - Jean-François Aubry
- Physics for Medicine Paris, INSERM, ESPCI Paris, CNRS, PSL Research University, Paris, France
| | - Nesrine Barnat
- Physics for Medicine Paris, INSERM, ESPCI Paris, CNRS, PSL Research University, Paris, France.,Theraclion, Malakoff, France
| |
Collapse
|
9
|
Kosari E, Vafai K. Thermal tissue damage analysis for magnetothermal neuromodulation and lesion size minimization. BRAIN MULTIPHYSICS 2020. [DOI: 10.1016/j.brain.2020.100014] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022] Open
|
10
|
Barnat N, Grisey A, Gerold B, Yon S, Anquez J, Aubry JF. Efficacy and safety assessment of an ultrasound-based thermal treatment of varicose veins in a sheep model. Int J Hyperthermia 2020; 37:231-244. [PMID: 32133898 DOI: 10.1080/02656736.2020.1734672] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022] Open
Abstract
Purpose: Varicose veins are a common pathology that can be treated by endovenous thermal procedures like radiofrequency ablation (RFA). Such catheter-based techniques consist in raising the temperature of the vein wall to 70 to 120 °C to induce vein wall coagulation. Although effective, this treatment option is not suited for all types of veins and can be technically challenging.Materials and methods: In this study, we used High-Intensity Focused Ultrasound (HIFU) as a non-invasive thermal ablation procedure to treat varicose veins and we assessed the long-term efficacy and safety of the procedure in a sheep model. In vivo experiments were first conducted on two saphenous veins to measure the temperature rise induced at the vein wall during HIFU ablation and were compared with reported RFA-induced thermal rise. Thermocouples were inserted in situ to perform 20 measurements during 8-s ultrasound pulses at 3 MHz. Eighteen saphenous veins of nine anesthetized sheep (2-2.5 % Isoflurane) were then exposed to similar pulses (85 W acoustic, 8 s). After treatments, animals recovered from anesthesia and were followed up 30, 60 and 90 days post-treatment (n = 3 animals per group). At the end of the follow-up, vein segments and perivenous tissues were harvested and histologically examined.Results: Temperatures induced by HIFU pulses were found to be comparable to reported RFA treatments. Likewise, histological findings were similar to the ones reported after RFA and laser-based coagulation necrosis of the vein wall, thrombotic occlusions and vein wall fibrosis.Conclusion: These results support strongly the effectiveness and safety of HIFU for ablating non-invasively veins.
Collapse
Affiliation(s)
- Nesrine Barnat
- Physics for Medicine Paris, Inserm, ESPCI Paris, CNRS, PSL Research University, Paris, France.,Theraclion, Malakoff, France
| | | | | | | | | | - Jean-François Aubry
- Physics for Medicine Paris, Inserm, ESPCI Paris, CNRS, PSL Research University, Paris, France
| |
Collapse
|
11
|
Chen J, LeBlang S, Hananel A, Aginsky R, Perez J, Gofeld M, Shir Y, Aubry JF. An incoherent HIFU transducer for treatment of the medial branch nerve: Numerical study and in vivo validation. Int J Hyperthermia 2020; 37:1219-1228. [PMID: 33106054 DOI: 10.1080/02656736.2020.1828628] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022] Open
Abstract
BACKGROUND Chronic back pain due to facet related degenerative changes affects 4-6 million patients a year in the United States. Patients refractory to conservative therapy may warrant targeted injections of steroids into the joint or percutaneous medial branch nerve denervation with radiofrequency ablation. We numerically tested a novel noninvasive high intensity focused ultrasound transducer to optimize nerve ablation near a bone-soft tissue interface. METHODS A transducer with 4 elements operating in an incoherent mode was modeled numerically and tested pre-clinically under fluoroscopic guidance. After 6 lumbar medial branch nerve ablations were performed in 2 pigs, they were followed clinically for 1 week and then sacrificed for pathological evaluation. RESULTS Simulations show that the acoustic spot size in water at 6 dB was 14mm axial x 1.6mm lateral and 52mm axial x 1.6mm lateral for coherent and incoherent modes, respectively. We measured the size of N = 6 lesions induced in vivo in a pig model and compared them to the size of the simulated thermal dose. The best match between the simulated and measured lesion size was found with a maximum absorption coefficient in the cortical bone adjusted to 30 dB/cm/MHz. This absorption was used to simulate clinical scenarios in humans to generate lesions with no potential side effects at 1000 and 1500 J. CONCLUSION The elongated spot obtained with the incoherent mode facilitates the targeting during fluoroscopic-guided medial branch nerve ablation.
Collapse
Affiliation(s)
- J Chen
- FUSMobile, Alpharetta, GA, USA
| | - S LeBlang
- Focused Ultrasound Foundation, Charlottesville, VA, USA
| | | | | | - J Perez
- McGill University, Montreal, Canada
| | - M Gofeld
- Silver Medical Group, North York, Canada
| | - Y Shir
- McGill University, Montreal, Canada
| | - J F Aubry
- Physics for Medicine Paris, Inserm, ESPCI Paris, CNRS, PSL Research University, Paris, France
| |
Collapse
|