Koivula L, Seppälä T, Collan J, Visapää H, Tenhunen M, Korhonen A. Synthetic computed tomography based dose calculation in prostate cancer patients with hip prostheses for magnetic resonance imaging-only radiotherapy. Phys Imaging Radiat Oncol 2023; 27:100469. [PMID: 37520639 PMCID: PMC10371839 DOI: 10.1016/j.phro.2023.100469] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2023] [Revised: 07/05/2023] [Accepted: 07/06/2023] [Indexed: 08/01/2023] Open
Abstract
Background and purpose Metallic hip prostheses cause substantial artefacts in both computed tomography (CT) and magnetic resonance (MR) images used in radiotherapy treatment planning (RTP) for prostate cancer patients. The aim of this study was to evaluate the dose calculation accuracy of a synthetic CT (sCT) generation workflow and the improvement in implant visibility using metal artefact reduction sequences. Materials and methods The study included 23 patients with prostate cancer who had hip prostheses, of which 10 patients had bilateral hip implants. An in-house protocol was applied to create sCT images for dose calculation comparison. The study compared prostheses volumes and resulting avoidance sectors against planning target volume (PTV) dose uniformity and organs at risk (OAR) sparing. Results Median PTV dose difference between sCT and CT-based dose calculation among all patients was 0.1 % (-0.4 to 0.4%) (median(range)). Bladder and rectum differences (V50Gy) were 0.2 % (-0.3 to 1.1%) and 0.1 % (-0.9 to 0.5%). The median 3D local gamma pass rate for partial arc cases using a Dixon MR sequence was Γ20%2mm/2% = 99.9%. For the bilateral full arc cases, using a metal artefact reconstruction sequence, the pass rate was Γ20%2mm/2% = 99.0%. Conclusions An in-house protocol for generating sCT images for dose calculation provided clinically feasible dose calculation accuracy for prostate cancer patients with hip implants. PTV median dose difference for uni- and bilateral patients with avoidance sectors remained <0.4%. The Outphase images enhanced implant visibility resulting in smaller avoidance sectors, better OAR sparing, and improved PTV uniformity.
Collapse
Affiliation(s)
- Lauri Koivula
- Department of Physics, MATRENA-doctoral programme, University of Helsinki, Gustaf Hällströmin katu 2, 00560 Helsinki, Finland
- Comprehensive Cancer Center, Helsinki University Hospital and University of Helsinki, Haartmaninkatu 4 Building 2, 00290 Helsinki, Finland
| | - Tiina Seppälä
- Comprehensive Cancer Center, Helsinki University Hospital and University of Helsinki, Haartmaninkatu 4 Building 2, 00290 Helsinki, Finland
| | - Juhani Collan
- Comprehensive Cancer Center, Helsinki University Hospital and University of Helsinki, Haartmaninkatu 4 Building 2, 00290 Helsinki, Finland
| | - Harri Visapää
- Comprehensive Cancer Center, Helsinki University Hospital and University of Helsinki, Haartmaninkatu 4 Building 2, 00290 Helsinki, Finland
| | - Mikko Tenhunen
- Comprehensive Cancer Center, Helsinki University Hospital and University of Helsinki, Haartmaninkatu 4 Building 2, 00290 Helsinki, Finland
| | - Arthur Korhonen
- Department of Medical Physics, Kymenlaakso Central Hospital, Kymenlaakso Social and Health Services (KymenHVA), Kotkantie 41, 48210 Kotka, Finland
| |
Collapse
|
2
|
Lane SA, Slater JM, Yang GY. Image-Guided Proton Therapy: A Comprehensive Review. Cancers (Basel) 2023; 15:cancers15092555. [PMID: 37174022 PMCID: PMC10177085 DOI: 10.3390/cancers15092555] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2023] [Revised: 04/24/2023] [Accepted: 04/26/2023] [Indexed: 05/15/2023] Open
Abstract
Image guidance for radiation therapy can improve the accuracy of the delivery of radiation, leading to an improved therapeutic ratio. Proton radiation is able to deliver a highly conformal dose to a target due to its advantageous dosimetric properties, including the Bragg peak. Proton therapy established the standard for daily image guidance as a means of minimizing uncertainties associated with proton treatment. With the increasing adoption of the use of proton therapy over time, image guidance systems for this modality have been changing. The unique properties of proton radiation present a number of differences in image guidance from photon therapy. This paper describes CT and MRI-based simulation and methods of daily image guidance. Developments in dose-guided radiation, upright treatment, and FLASH RT are discussed as well.
Collapse
Affiliation(s)
- Shelby A Lane
- James M. Slater, MD Proton Treatment and Research Center, Loma Linda University, Loma Linda, CA 92354, USA
| | - Jason M Slater
- James M. Slater, MD Proton Treatment and Research Center, Loma Linda University, Loma Linda, CA 92354, USA
| | - Gary Y Yang
- James M. Slater, MD Proton Treatment and Research Center, Loma Linda University, Loma Linda, CA 92354, USA
| |
Collapse
|
3
|
Pediatric radiotherapy for thoracic and abdominal targets: organ motion, reported margin sizes, and delineation variations – a systematic review. Radiother Oncol 2022; 173:134-145. [DOI: 10.1016/j.radonc.2022.05.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2021] [Revised: 05/09/2022] [Accepted: 05/26/2022] [Indexed: 11/21/2022]
|
4
|
Olberg S, Chun J, Su Choi B, Park I, Kim H, Kim T, Sung Kim J, Green O, Park JC. Abdominal synthetic CT reconstruction with intensity projection prior for MRI-only adaptive radiotherapy. Phys Med Biol 2021; 66. [PMID: 34530421 DOI: 10.1088/1361-6560/ac279e] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2021] [Accepted: 09/16/2021] [Indexed: 11/11/2022]
Abstract
Objective. Owing to the superior soft tissue contrast of MRI, MRI-guided adaptive radiotherapy (ART) is well-suited to managing interfractional changes in anatomy. An MRI-only workflow is desirable, but producing synthetic CT (sCT) data through paired data-driven deep learning (DL) for abdominal dose calculations remains a challenge due to the highly variable presence of intestinal gas. We present the preliminary dosimetric evaluation of our novel approach to sCT reconstruction that is well suited to handling intestinal gas in abdominal MRI-only ART.Approach. We utilize a paired data DL approach enabled by the intensity projection prior, in which well-matching training pairs are created by propagating air from MRI to corresponding CT scans. Evaluations focus on two classes: patients with (1) little involvement of intestinal gas, and (2) notable differences in intestinal gas presence between corresponding scans. Comparisons between sCT-based plans and CT-based clinical plans for both classes are made at the first treatment fraction to highlight the dosimetric impact of the variable presence of intestinal gas.Main results. Class 1 patients (n= 13) demonstrate differences in prescribed dose coverage of the PTV of 1.3 ± 2.1% between clinical plans and sCT-based plans. Mean DVH differences in all structures for Class 1 patients are found to be statistically insignificant. In Class 2 (n= 20), target coverage is 13.3 ± 11.0% higher in the clinical plans and mean DVH differences are found to be statistically significant.Significance. Significant deviations in calculated doses arising from the variable presence of intestinal gas in corresponding CT and MRI scans result in uncertainty in high-dose regions that may limit the effectiveness of adaptive dose escalation efforts. We have proposed a paired data-driven DL approach to sCT reconstruction for accurate dose calculations in abdominal ART enabled by the creation of a clinically unavailable training data set with well-matching representations of intestinal gas.
Collapse
Affiliation(s)
- Sven Olberg
- Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75390, United States of America.,Department of Biomedical Engineering, Washington University in St. Louis, St. Louis, MO 63110, United States of America
| | - Jaehee Chun
- Department of Radiation Oncology, Yonsei Cancer Center, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Byong Su Choi
- Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75390, United States of America.,Department of Radiation Oncology, Yonsei Cancer Center, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Inkyung Park
- Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75390, United States of America.,Department of Radiation Oncology, Yonsei Cancer Center, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Hyun Kim
- Department of Radiation Oncology, Washington University in St. Louis, St. Louis, MO 63110, United States of America
| | - Taeho Kim
- Department of Radiation Oncology, Washington University in St. Louis, St. Louis, MO 63110, United States of America
| | - Jin Sung Kim
- Department of Radiation Oncology, Yonsei Cancer Center, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Olga Green
- Department of Radiation Oncology, Washington University in St. Louis, St. Louis, MO 63110, United States of America
| | - Justin C Park
- Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75390, United States of America
| |
Collapse
|
5
|
Guerreiro F, Svensson S, Seravalli E, Traneus E, Raaymakers BW. Intra-fractional per-beam adaptive workflow to mitigate the need for a rotating gantry during MRI-guided proton therapy. Phys Med Biol 2021; 66. [PMID: 34298523 DOI: 10.1088/1361-6560/ac176f] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2021] [Accepted: 07/23/2021] [Indexed: 11/12/2022]
Abstract
The integration of real-time magnetic resonance imaging (MRI)-guidance and proton therapy would potentially improve the proton dose steering capability by reducing daily uncertainties due to anatomical variations. The use of a fixed beamline coupled with an axial patient couch rotation would greatly simplify the proton delivery with MRI-guidance. Nonetheless, it is mandatory to assure that the plan quality is not deteriorated by the anatomical deformations due to patient rotation. In this work, an in-house tool allowing for intra-fractional per-beam adaptation of intensity-modulated proton plans (BeamAdapt) was implemented through features available in RayStation. A set of three MRIs was acquired for two healthy volunteers (V1, V2): (1) no rotation/static, (2) rotation to the right and (3) left. V1 was rotated by 15º, to simulate a clinical pediatric abdominal case and V2 by 45º, to simulate an extreme patient rotation case. For each volunteer, a total of four intensity-modulated pencil beam scanning plans were optimized on the static MRI using virtual abdominal targets and 2-3 posterior-oblique beams. Beam angles were defined according to the angulations on the rotated MRIs. With BeamAdapt, each original plan was first converted into separate plans with one beam per plan. In an iterative order, individual beam doses were non-rigidly deformed to the rotated anatomies and re-optimized accounting for the consequent deformations and the beam doses delivered so far. For evaluation, the final adapted dose distribution was propagated back to the static MRI. Planned and adapted dose distributions were compared by computing relative differences between dose-volume histogram (DVH) metrics. Absolute target dose differences were on average below 1% and mean dose organs-at-risk differences were below 3%. With BeamAdapt, not only intra-fractional per-beam proton plan adaptation coupled with axial patient rotation is possible but also the need for a rotating gantry during MRI-guidance might be mitigated.
Collapse
Affiliation(s)
- Filipa Guerreiro
- Department of Radiotherapy, University Medical Center Utrecht Imaging Division, Utrecht, NETHERLANDS
| | | | - Enrica Seravalli
- Department of Radiotherapy, University Medical Center Utrecht Imaging Division, Utrecht, NETHERLANDS
| | - Erik Traneus
- RaySearch Laboratories AB, Stockholm, Stockholm, SWEDEN
| | - Bas W Raaymakers
- Department of Radiotherapy, University Medical Center Utrecht Imaging Division, Utrecht, NETHERLANDS
| |
Collapse
|
6
|
Irmak S, Zimmermann L, Georg D, Kuess P, Lechner W. Cone beam CT based validation of neural network generated synthetic CTs for radiotherapy in the head region. Med Phys 2021; 48:4560-4571. [PMID: 34028053 DOI: 10.1002/mp.14987] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2020] [Revised: 05/06/2021] [Accepted: 05/09/2021] [Indexed: 11/10/2022] Open
Abstract
PURPOSE In the past years, many different neural network-based conversion techniques for synthesizing computed tomographys (sCTs) from MR images have been published. While the model's performance can be checked during the training against the test set, test datasets can never represent the whole population. Conversion errors can still occur for special cases, for example, for unusual anatomical situations. Therefore, the performance of sCT conversion needs to be verified on a patient specific level, especially in the absence of a planning CT (pCT). In this study, the capability of cone-beam CTs (CBCTs) for the validation of sCTs generated by a neural network was investigated. METHODS 41 patients with tumors in the head region were selected. 20 of them were used for model training and 10 for validation. Different implementations of CycleGAN (with/without identity and feature loss) were used to generate sCTs. The pixel (MAE, RMSE, PSNR) and geometric error (DICE, Sensitivity, Specificity) values were reported to identify the best model. VMAT plans were created for the remaining 11 patients on the pCTs. These plans were re-calculated on sCTs and CBCTs. An automatic density overriding method ( C B C T RS ) and a population-based dose calculation method ( C B C T Pop ) were employed for CBCT-based dose calculation. The dose distributions were analysed using 3D global gamma analysis, applying a threshold of 10% with respect to the prescribed dose. Differences in DVH metrics for the PTV and the organs-at-risk were compared among the dose distributions based on pCTs, sCTs, and CBCTs. RESULTS The best model was the CycleGAN without identity and feature matching loss. Including the identity loss led to a metric decrease of 10% for DICE and a metric increase of 20-60 HU for MAE. Using the 2%/2 mm gamma criterion and pCT as reference, the mean gamma pass rates were 99.0 ± 0.4% for sCTs. Mean gamma pass rate values comparing pCT and CBCT were 99.0 ± 0.8% and 99.1 ± 0.8% for the C B C T RS and C B C T Pop , respectively. The mean gamma pass rates comparing sCT and CBCT resulted in 98.4 ± 1.6% and 99.2 ± 0.6% for C B C T RS and C B C T Pop , respectively. The differences between the gamma-pass-rates of the sCT and two CBCT-based methods were not significant. The majority of deviations of the investigated DVH metrices between sCTs and CBCTs were within 2%. CONCLUSION The dosimetric results demonstrate good agreement between sCT, CBCT, and pCT based calculations. A properly applied CBCT conversion method can serve as a tool for quality assurance procedures in an MR only radiotherapy workflow for head patients. Dosimetric deviations of DVH metrics between sCT and CBCTs of larger than 2% should be followed up. A systematic shift of approximately 1% should be taken into account when using the C B C T RS approach in an MR only workflow.
Collapse
Affiliation(s)
- Sinan Irmak
- Department of Radiation Oncology, Medical University of Vienna, Vienna, Austria
| | - Lukas Zimmermann
- Department of Radiation Oncology, Medical University of Vienna, Vienna, Austria.,Faculty of Engineering, University of Applied Sciences, Wiener Neustadt, Austria.,Competence Center for Preclinical Imaging and Biomedical Engineering, University of Applied Sciences, Wiener Neustadt, Austria
| | - Dietmar Georg
- Department of Radiation Oncology, Medical University of Vienna, Vienna, Austria
| | - Peter Kuess
- Department of Radiation Oncology, Medical University of Vienna, Vienna, Austria
| | - Wolfgang Lechner
- Department of Radiation Oncology, Medical University of Vienna, Vienna, Austria
| |
Collapse
|
7
|
Hua CH, Mascia AE, Servalli E, Lomax AJ, Seiersen K, Ulin K. Advances in radiotherapy technology for pediatric cancer patients and roles of medical physicists: COG and SIOP Europe perspectives. Pediatr Blood Cancer 2021; 68 Suppl 2:e28344. [PMID: 33818892 PMCID: PMC8030241 DOI: 10.1002/pbc.28344] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/30/2020] [Revised: 03/27/2020] [Accepted: 04/02/2020] [Indexed: 11/11/2022]
Abstract
Over the last two decades, rapid technological advances have dramatically changed radiation delivery to children with cancer, enabling improved normal-tissue sparing. This article describes recent advances in photon and proton therapy technologies, image-guided patient positioning, motion management, and adaptive therapy that are relevant to pediatric cancer patients. For medical physicists who are at the forefront of realizing the promise of technology, challenges remain with respect to ensuring patient safety as new technologies are implemented with increasing treatment complexity. The contributions of medical physicists to meeting these challenges in daily practice, in the conduct of clinical trials, and in pediatric oncology cooperative groups are highlighted. Representing the perspective of the physics committees of the Children's Oncology Group (COG) and the European Society for Paediatric Oncology (SIOP Europe), this paper provides recommendations regarding the safe delivery of pediatric radiotherapy. Emerging innovations are highlighted to encourage pediatric applications with a view to maximizing the therapeutic ratio.
Collapse
Affiliation(s)
- Chia-ho Hua
- Department of Radiation Oncology, St. Jude Children’s Research Hospital, Memphis, Tennessee, USA
| | - Anthony E. Mascia
- Department of Radiation Oncology, University of Cincinnati, Cincinnati, Ohio, USA
| | - Enrica Servalli
- Department of Radiotherapy, University Medical Center Utrecht, The Netherlands
| | - Antony J. Lomax
- Center for Proton Therapy, Paul Scherrer Institute, PSI Villigen, Switzerland
| | | | - Kenneth Ulin
- Department of Radiation Oncology, University of Massachusetts, Worcester, Massachusetts, USA
| |
Collapse
|
8
|
Paganetti H, Beltran C, Both S, Dong L, Flanz J, Furutani K, Grassberger C, Grosshans DR, Knopf AC, Langendijk JA, Nystrom H, Parodi K, Raaymakers BW, Richter C, Sawakuchi GO, Schippers M, Shaitelman SF, Teo BKK, Unkelbach J, Wohlfahrt P, Lomax T. Roadmap: proton therapy physics and biology. Phys Med Biol 2021; 66. [DOI: 10.1088/1361-6560/abcd16] [Citation(s) in RCA: 30] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2020] [Accepted: 11/23/2020] [Indexed: 12/12/2022]
|
9
|
Zimmermann L, Buschmann M, Herrmann H, Heilemann G, Kuess P, Goldner G, Nyholm T, Georg D, Nesvacil N. An MR-only acquisition and artificial intelligence based image-processing protocol for photon and proton therapy using a low field MR. Z Med Phys 2021; 31:78-88. [PMID: 33455822 DOI: 10.1016/j.zemedi.2020.10.004] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2020] [Revised: 09/14/2020] [Accepted: 10/27/2020] [Indexed: 10/22/2022]
Abstract
OBJECTIVE Recent developments on synthetically generated CTs (sCT), hybrid MRI linacs and MR-only simulations underlined the clinical feasibility and acceptance of MR guided radiation therapy. However, considering clinical application of open and low field MR with a limited field of view can result in truncation of the patient's anatomy which further affects the MR to sCT conversion. In this study an acquisition protocol and subsequent MR image stitching is proposed to overcome the limited field of view restriction of open MR scanners, for MR-only photon and proton therapy. MATERIAL AND METHODS 12 prostate cancer patients scanned with an open 0.35T scanner were included. To obtain the full body contour an enhanced imaging protocol including two repeated scans after bilateral table movement was introduced. All required structures (patient contour, target and organ at risk) were delineated on a post-processed combined transversal image set (stitched MRI). The postprocessed MR was converted into a sCT by a pretrained neural network generator. Inversely planned photon and proton plans (VMAT and SFUD) were designed using the sCT and recalculated for rigidly and deformably registered CT images and compared based on D2%, D50%, V70Gy for organs at risk and based on D2%, D50%, D98% for the CTV and PTV. The stitched MRI and the untruncated MRI were compared to the CT, and the maximum surface distance was calculated. The sCT was evaluated with respect to delineation accuracy by comparing on stitched MRI and sCT using the DICE coefficient for femoral bones and the whole body. RESULTS Maximum surface distance analysis revealed uncertainties in lateral direction of 1-3mm on average. DICE coefficient analysis confirms good performance of the sCT conversion, i.e. 92%, 93%, and 100% were obtained for femoral bone left and right and whole body. Dose comparison resulted in uncertainties below 1% between deformed CT and sCT and below 2% between rigidly registered CT and sCT in the CTV for photon and proton treatment plans. DISCUSSION A newly developed acquisition protocol for open MR scanners and subsequent Sct generation revealed good acceptance for photon and proton therapy. Moreover, this protocol tackles the restriction of the limited FOVs and expands the capacities towards MR guided proton therapy with horizontal beam lines.
Collapse
Affiliation(s)
- Lukas Zimmermann
- Division of Medical Radiation Physics, Department of Radiation Oncology, Medical University of Vienna, Vienna, Austria.
| | - Martin Buschmann
- Division of Medical Radiation Physics, Department of Radiation Oncology, Medical University of Vienna, Vienna, Austria
| | - Harald Herrmann
- Division of Medical Radiation Physics, Department of Radiation Oncology, Medical University of Vienna, Vienna, Austria
| | - Gerd Heilemann
- Division of Medical Radiation Physics, Department of Radiation Oncology, Medical University of Vienna, Vienna, Austria
| | - Peter Kuess
- Division of Medical Radiation Physics, Department of Radiation Oncology, Medical University of Vienna, Vienna, Austria
| | - Gregor Goldner
- Division of Medical Radiation Physics, Department of Radiation Oncology, Medical University of Vienna, Vienna, Austria
| | - Tufve Nyholm
- Department of Radiation Sciences, Umeå University, Umeå, Sweden
| | - Dietmar Georg
- Division of Medical Radiation Physics, Department of Radiation Oncology, Medical University of Vienna, Vienna, Austria
| | - Nicole Nesvacil
- Division of Medical Radiation Physics, Department of Radiation Oncology, Medical University of Vienna, Vienna, Austria
| |
Collapse
|
10
|
Thummerer A, de Jong BA, Zaffino P, Meijers A, Marmitt GG, Seco J, Steenbakkers RJHM, Langendijk JA, Both S, Spadea MF, Knopf AC. Comparison of the suitability of CBCT- and MR-based synthetic CTs for daily adaptive proton therapy in head and neck patients. ACTA ACUST UNITED AC 2020; 65:235036. [DOI: 10.1088/1361-6560/abb1d6] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
|
11
|
Maspero M, Bentvelzen LG, Savenije MH, Guerreiro F, Seravalli E, Janssens GO, van den Berg CA, Philippens ME. Deep learning-based synthetic CT generation for paediatric brain MR-only photon and proton radiotherapy. Radiother Oncol 2020; 153:197-204. [DOI: 10.1016/j.radonc.2020.09.029] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2020] [Revised: 09/14/2020] [Accepted: 09/14/2020] [Indexed: 02/07/2023]
|
12
|
Florkow MC, Guerreiro F, Zijlstra F, Seravalli E, Janssens GO, Maduro JH, Knopf AC, Castelein RM, van Stralen M, Raaymakers BW, Seevinck PR. Deep learning-enabled MRI-only photon and proton therapy treatment planning for paediatric abdominal tumours. Radiother Oncol 2020; 153:220-227. [DOI: 10.1016/j.radonc.2020.09.056] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2020] [Revised: 09/24/2020] [Accepted: 09/28/2020] [Indexed: 01/24/2023]
|
13
|
Dumlu HS, Meschini G, Kurz C, Kamp F, Baroni G, Belka C, Paganelli C, Riboldi M. Dosimetric impact of geometric distortions in an MRI-only proton therapy workflow for lung, liver and pancreas. Z Med Phys 2020; 32:85-97. [PMID: 33168274 PMCID: PMC9948883 DOI: 10.1016/j.zemedi.2020.10.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2020] [Revised: 09/02/2020] [Accepted: 10/01/2020] [Indexed: 12/25/2022]
Abstract
In a radiation therapy workflow based on Magnetic Resonance Imaging (MRI), dosimetric errors may arise due to geometric distortions introduced by MRI. The aim of this study was to quantify the dosimetric effect of system-dependent geometric distortions in an MRI-only workflow for proton therapy applied at extra-cranial sites. An approach was developed, in which computed tomography (CT) images were distorted using an MRI displacement map, which represented the MR distortions in a spoiled gradient-echo sequence due to gradient nonlinearities and static magnetic field inhomogeneities. A retrospective study was conducted on 4DCT/MRI digital phantoms and 18 4DCT clinical datasets of the thoraco-abdominal site. The treatment plans were designed and separately optimized for each beam in a beam specific Planning Target Volume on the distorted CT, and the final dose distribution was obtained as the average. The dose was then recalculated in undistorted CT using the same beam geometry and beam weights. The analysis was performed in terms of Dose Volume Histogram (DVH) parameters. No clinically relevant dosimetric impact was observed on organs at risk, whereas in the target structure, geometric distortions caused statistically significant variations in the planned dose DVH parameters and dose homogeneity index (DHI). The dosimetric variations in the target structure were smaller in abdominal cases (ΔD2%, ΔD98%, and ΔDmean all below 0.1% and ΔDHI below 0.003) compared to the lung cases. Indeed, lung patients with tumors isolated inside lung parenchyma exhibited higher dosimetric variations (ΔD2%≥0.3%, ΔD98%≥15.9%, ΔDmean≥3.3% and ΔDHI≥0.102) than lung patients with tumor close to soft tissue (ΔD2%≤0.4%, ΔD98%≤5.6%, ΔDmean≤0.9% and ΔDHI≤0.027) potentially due to higher density variations along the beam path. Results suggest the potential applicability of MRI-only proton therapy, provided that specific analysis is applied for isolated lung tumors.
Collapse
Affiliation(s)
- Hatice Selcen Dumlu
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Via Ponzio 34/5, 20133 Milano, Italy; Department of Medical Physics, Faculty of Physics, Ludwig-Maximilians-Universität München, Am Coulombwall 1, 85748 Garching bei München, Germany
| | - Giorgia Meschini
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Via Ponzio 34/5, 20133 Milano, Italy
| | - Christopher Kurz
- Department of Radiation Oncology, University Hospital, LMU Munich, Marchioninistraße 15, 81377 München, Germany
| | - Florian Kamp
- Department of Radiation Oncology, University Hospital, LMU Munich, Marchioninistraße 15, 81377 München, Germany
| | - Guido Baroni
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Via Ponzio 34/5, 20133 Milano, Italy; Centro Nazionale di Adroterapia Oncologica, Strada Campeggi 53, 27100 Pavia, Italy
| | - Claus Belka
- Department of Radiation Oncology, University Hospital, LMU Munich, Marchioninistraße 15, 81377 München, Germany; German Cancer Consortium (DKTK) partner site Munich, Germany and German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg, Germany
| | - Chiara Paganelli
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Via Ponzio 34/5, 20133 Milano, Italy
| | - Marco Riboldi
- Department of Medical Physics, Faculty of Physics, Ludwig-Maximilians-Universität München, Am Coulombwall 1, 85748 Garching bei München, Germany.
| |
Collapse
|
14
|
Meschini G, Vai A, Paganelli C, Molinelli S, Maestri D, Fontana G, Pella A, Vitolo V, Valvo F, Ciocca M, Baroni G. Investigating the use of virtual 4DCT from 4DMRI in gated carbon ion radiation therapy of abdominal tumors. Z Med Phys 2020; 32:98-108. [PMID: 33069586 PMCID: PMC9948849 DOI: 10.1016/j.zemedi.2020.08.005] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2020] [Revised: 07/27/2020] [Accepted: 08/31/2020] [Indexed: 12/22/2022]
Abstract
PURPOSE To generate virtual 4DCT from 4DMRI with field of view (FOV) extended to the entire involved patient anatomy, in order to evaluate its use in carbon ion radiation therapy (CIRT) of the abdominal site in a clinical scenario. MATERIALS AND METHODS The virtual 4DCT was generated by deforming a reference CT in order to (1) match the anatomy depicted in the 4DMRI within its FOV, by calculating deformation fields with deformable image registration to describe inter-fractional and breathing motion, and (2) obtain physically plausible deformation outside of the 4DMRI FOV, by propagating and modulating the previously obtained deformation fields. The implemented method was validated on a digital anthropomorphic phantom, for which a ground truth (GT) 4DCT was available. A CIRT treatment plan was optimized at the end-exhale reference CT and the RBE-weighted dose distribution was recalculated on both the virtual and GT 4DCTs. The method estimation error was quantified by comparing the virtual and GT 4DCTs and the corresponding recomputed doses. The method was then evaluated on 8 patients with pancreas or liver tumors treated with CIRT using respiratory gating at end-exhale. The clinical treatment plans adopted at the National Center for Oncological Hadrontherapy (CNAO, Pavia, Italy) were considered and the dose distribution was recomputed on all respiratory phases of the planning and virtual 4DCTs. By comparing the two datasets and the corresponding dose distributions, the geometrical and dosimetric impact of organ motion was assessed. RESULTS For the phantom, the error outside of the 4DMRI FOV was up to 4.5mm, but it remained sub-millimetric in correspondence to the target within the 4DMRI FOV. Although the impact of motion on the target D95% resulted in variations ranging from 22% to 90% between the planned dose and the doses recomputed on the GT 4DCT phases, the corresponding estimation error was ≤2.2%. In the patient cases, the variation of the baseline tumor position between the planning and the virtual end-exhale CTs presented a median (interquartile range) value of 6.0 (4.9) mm. For baseline variations larger than 5mm, the tumor D95% variation between the plan and the dose recomputed on the end-exhale virtual CT resulted larger than 10%. Median variations higher than 10% in the target D95% and gastro-intestinal OARs D2% were quantified at the end-inhale, whereas close to the end-exhale phase, limited variations of relevant dose metrics were found for both tumor and OARs. CONCLUSIONS The negligible impact of the geometrical inaccuracy in the estimated anatomy outside of the 4DMRI FOV on the overall dosimetric accuracy suggests the feasibility of virtual 4DCT with extended FOV in CIRT of the abdominal site. In the analyzed patient group, inter-fractional variations such as baseline variation and breathing variability were quantified, demonstrating the method capability to support treatment planning in gated CIRT of the abdominal site.
Collapse
Affiliation(s)
- Giorgia Meschini
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milano 20133, Italy.
| | - Alessandro Vai
- Centro Nazionale di Adroterapia Oncologica, Pavia 27100, Italy
| | - Chiara Paganelli
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milano 20133, Italy
| | | | - Davide Maestri
- Centro Nazionale di Adroterapia Oncologica, Pavia 27100, Italy
| | - Giulia Fontana
- Centro Nazionale di Adroterapia Oncologica, Pavia 27100, Italy
| | - Andrea Pella
- Centro Nazionale di Adroterapia Oncologica, Pavia 27100, Italy
| | - Viviana Vitolo
- Centro Nazionale di Adroterapia Oncologica, Pavia 27100, Italy
| | - Francesca Valvo
- Centro Nazionale di Adroterapia Oncologica, Pavia 27100, Italy
| | - Mario Ciocca
- Centro Nazionale di Adroterapia Oncologica, Pavia 27100, Italy
| | - Guido Baroni
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milano 20133, Italy,Centro Nazionale di Adroterapia Oncologica, Pavia 27100, Italy
| |
Collapse
|
15
|
Hoffmann A, Oborn B, Moteabbed M, Yan S, Bortfeld T, Knopf A, Fuchs H, Georg D, Seco J, Spadea MF, Jäkel O, Kurz C, Parodi K. MR-guided proton therapy: a review and a preview. Radiat Oncol 2020; 15:129. [PMID: 32471500 PMCID: PMC7260752 DOI: 10.1186/s13014-020-01571-x] [Citation(s) in RCA: 73] [Impact Index Per Article: 18.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2019] [Accepted: 05/17/2020] [Indexed: 02/14/2023] Open
Abstract
Background The targeting accuracy of proton therapy (PT) for moving soft-tissue tumours is expected to greatly improve by real-time magnetic resonance imaging (MRI) guidance. The integration of MRI and PT at the treatment isocenter would offer the opportunity of combining the unparalleled soft-tissue contrast and real-time imaging capabilities of MRI with the most conformal dose distribution and best dose steering capability provided by modern PT. However, hybrid systems for MR-integrated PT (MRiPT) have not been realized so far due to a number of hitherto open technological challenges. In recent years, various research groups have started addressing these challenges and exploring the technical feasibility and clinical potential of MRiPT. The aim of this contribution is to review the different aspects of MRiPT, to report on the status quo and to identify important future research topics. Methods Four aspects currently under study and their future directions are discussed: modelling and experimental investigations of electromagnetic interactions between the MRI and PT systems, integration of MRiPT workflows in clinical facilities, proton dose calculation algorithms in magnetic fields, and MRI-only based proton treatment planning approaches. Conclusions Although MRiPT is still in its infancy, significant progress on all four aspects has been made, showing promising results that justify further efforts for research and development to be undertaken. First non-clinical research solutions have recently been realized and are being thoroughly characterized. The prospect that first prototype MRiPT systems for clinical use will likely exist within the next 5 to 10 years seems realistic, but requires significant work to be performed by collaborative efforts of research groups and industrial partners.
Collapse
Affiliation(s)
- Aswin Hoffmann
- OncoRay - National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden-Rossendorf, Dresden, Germany.,Helmholtz-Zentrum Dresden-Rossendorf, Institute of Radiooncology-OncoRay, Dresden, Germany.,Department of Radiotherapy and Radiation Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany
| | - Bradley Oborn
- Centre for Medical Radiation Physics, University of Wollongong, Wollongong, Australia.,Illawarra Cancer Care Centre, Wollongong Hospital, Wollongong, Australia
| | - Maryam Moteabbed
- Division of Radiation Biophysics, Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, USA
| | - Susu Yan
- Division of Radiation Biophysics, Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, USA
| | - Thomas Bortfeld
- Division of Radiation Biophysics, Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, USA
| | - Antje Knopf
- Department of Radiation Oncology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| | - Herman Fuchs
- Department of Radiation Oncology, Medical University of Vienna/AKH, Vienna, Austria.,Christian Doppler Laboratory for Medical Radiation Research for Radiation Oncology, Medical University of Vienna, Vienna, Austria
| | - Dietmar Georg
- Department of Radiation Oncology, Medical University of Vienna/AKH, Vienna, Austria.,Christian Doppler Laboratory for Medical Radiation Research for Radiation Oncology, Medical University of Vienna, Vienna, Austria
| | - Joao Seco
- Biomedical Physics in Radiation Oncology, Deutsches Krebsforschungszentrum DKFZ, Heidelberg, Germany.,Department of Physics and Astronomy, Heidelberg University, Heidelberg, Germany
| | - Maria Francesca Spadea
- Biomedical Physics in Radiation Oncology, Deutsches Krebsforschungszentrum DKFZ, Heidelberg, Germany.,Department of Experimental and Clinical Medicine, Magna Graecia University, Catanzaro, Italy
| | - Oliver Jäkel
- Medical Physics in Radiation Oncology, Deutsches Krebsforschungszentrum DKFZ and Heidelberg Ion-Beam Therapy Center at the University Medical Center, Heidelberg, Germany
| | - Christopher Kurz
- Department of Radiation Oncology, University Hospital, LMU Munich, Munich, Germany.,Department of Medical Physics, Faculty of Physics, Ludwig-Maximilians-Universität München, Garching, Germany
| | - Katia Parodi
- Department of Medical Physics, Faculty of Physics, Ludwig-Maximilians-Universität München, Garching, Germany.
| |
Collapse
|
16
|
Albertini F, Matter M, Nenoff L, Zhang Y, Lomax A. Online daily adaptive proton therapy. Br J Radiol 2020; 93:20190594. [PMID: 31647313 PMCID: PMC7066958 DOI: 10.1259/bjr.20190594] [Citation(s) in RCA: 81] [Impact Index Per Article: 20.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2019] [Revised: 10/15/2019] [Accepted: 10/22/2019] [Indexed: 12/11/2022] Open
Abstract
It is recognized that the use of a single plan calculated on an image acquired some time before the treatment is generally insufficient to accurately represent the daily dose to the target and to the organs at risk. This is particularly true for protons, due to the physical finite range. Although this characteristic enables the generation of steep dose gradients, which is essential for highly conformal radiotherapy, it also tightens the dependency of the delivered dose to the range accuracy. In particular, the use of an outdated patient anatomy is one of the most significant sources of range inaccuracy, thus affecting the quality of the planned dose distribution. A plan should be ideally adapted as soon as anatomical variations occur, ideally online. In this review, we describe in detail the different steps of the adaptive workflow and discuss the challenges and corresponding state-of-the art developments in particular for an online adaptive strategy.
Collapse
Affiliation(s)
| | | | | | - Ye Zhang
- Paul Scherrer Institute, Center for Proton Therapy, Switzerland
| | | |
Collapse
|
17
|
Hsu SH, DuPre P, Peng Q, Tomé WA. A technique to generate synthetic CT from MRI for abdominal radiotherapy. J Appl Clin Med Phys 2020; 21:136-143. [PMID: 32043812 PMCID: PMC7020981 DOI: 10.1002/acm2.12816] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2019] [Revised: 11/20/2019] [Accepted: 12/12/2019] [Indexed: 12/22/2022] Open
Abstract
Purpose To investigate a method to classify tissues types for synthetic CT generation using MRI for treatment planning in abdominal radiotherapy. Methods An institutional review board approved volunteer study was performed on a 3T MRI scanner. In‐phase, fat and water images were acquired for five volunteers with breath‐hold using an mDixon pulse sequence. A method to classify different tissue types for synthetic CT generation in the abdomen was developed. Three tissue clusters (fat, high‐density tissue, and spine/air/lungs) were generated using a fuzzy‐c means clustering algorithm. The third cluster was further segmented into three sub‐clusters that represented spine, air, and lungs. Therefore, five segments were automatically generated. To evaluate segmentation accuracy using the method, the five segments were manually contoured on MRI images as the ground truth, and the volume ratio, Dice coefficient, and Hausdorff distance metric were calculated. The dosimetric effect of segmentation accuracy was evaluated on simulated targets close to air, lungs, and spine using a two‐arc volumetric modulated arc therapy (VMAT) technique. Results The volume ratio of auto‐segmentation to manual segmentation was 0.88–2.1 for the air segment and 0.72–1.13 for the remaining segments. The range of the Dice coefficient was 0.24–0.83, 0.84–0.93, 0.94–0.98, 0.93–0.96, and 0.76–0.79 for air, fat, lungs, high‐density tissue, and spine, respectively. The range of the mean Hausdorff distance was 3–29.1 mm, 0.5–1.3 mm, 0.4–1 mm, 0.7–1.6 mm, and 1.2–1.4 mm for air, fat, lungs, high‐density tissue, and spine, respectively. Despite worse segmentation accuracy in air and spine, the dosimetric effect was 0.2% ± 0.2%, with a maximum difference of 0.8% for all target locations. Conclusion A method to generate synthetic CT in the abdomen was developed, and segmentation accuracy and its dosimetric effect were evaluated. Our results demonstrate the potential of using MRI alone for treatment planning in the abdomen.
Collapse
Affiliation(s)
- Shu-Hui Hsu
- Department of Radiation Oncology, Montefiore Medical Center, Bronx, NY, USA.,Institute for Onco-Physics, Albert Einstein College of Medicine, Bronx, NY, USA
| | - Pamela DuPre
- Department of Radiation Oncology, Montefiore Medical Center, Bronx, NY, USA
| | - Qi Peng
- Gruss Magnetic Resonance Research Center, Albert Einstein College of Medicine, Bronx, NY, USA.,Department of Radiology, Montefiore Medical Center, Bronx, NY, USA
| | - Wolfgang A Tomé
- Department of Radiation Oncology, Montefiore Medical Center, Bronx, NY, USA.,Institute for Onco-Physics, Albert Einstein College of Medicine, Bronx, NY, USA
| |
Collapse
|
18
|
Meschini G, Vai A, Paganelli C, Molinelli S, Fontana G, Pella A, Preda L, Vitolo V, Valvo F, Ciocca M, Riboldi M, Baroni G. Virtual 4DCT from 4DMRI for the management of respiratory motion in carbon ion therapy of abdominal tumors. Med Phys 2020; 47:909-916. [PMID: 31880819 DOI: 10.1002/mp.13992] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2019] [Revised: 12/17/2019] [Accepted: 12/17/2019] [Indexed: 12/12/2022] Open
Abstract
PURPOSE To evaluate a method for generating virtual four-dimensional computed tomography (4DCT) from four-dimensional magnetic resonance imaging (4DMRI) data in carbon ion radiotherapy with pencil beam scanning for abdominal tumors. METHODS Deformable image registration is used to: (a) register each respiratory phase of the 4DMRI to the end-exhale MRI; (b) register the reference end-exhale CT to the end-exhale MRI volume; (c) generate the virtual 4DCT by warping the registered CT according to the obtained deformation fields. A respiratory-gated carbon ion treatment plan is optimized on the planning 4DCT and the corresponding dose distribution is recalculated on the virtual 4DCT. The method was validated on a digital anthropomorphic phantom and tested on eight patients (18 acquisitions). For the phantom, a ground truth dataset was available to assess the method performances from the geometrical and dosimetric standpoints. For the patients, the virtual 4DCT was compared with the planning 4DCT. RESULTS In the phantom, the method exhibits a geometrical accuracy within the voxel size and Dose Volume Histograms deviations up to 3.3% for target V95% (mean dose difference ≤ 0.2% of the prescription dose, gamma pass rate > 98%). For patients, the virtual and the planning 4DCTs show good agreement at end-exhale (3% median D95% difference), whereas other respiratory phases exhibit moderate motion variability with consequent dose discrepancies, confirming the need for motion mitigation strategies during treatment. CONCLUSIONS The virtual 4DCT approach is feasible to evaluate treatment plan robustness against intra- and interfraction motion in carbon ion therapy delivered at the abdominal site.
Collapse
Affiliation(s)
- Giorgia Meschini
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milano, 20133, Italy
| | - Alessandro Vai
- Centro Nazionale di Adroterapia Oncologica, Pavia, 27100, Italy
| | - Chiara Paganelli
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milano, 20133, Italy
| | | | - Giulia Fontana
- Centro Nazionale di Adroterapia Oncologica, Pavia, 27100, Italy
| | - Andrea Pella
- Centro Nazionale di Adroterapia Oncologica, Pavia, 27100, Italy
| | - Lorenzo Preda
- Centro Nazionale di Adroterapia Oncologica, Pavia, 27100, Italy.,Department of Clinical, Surgical, Diagnostic and Pediatric Sciences, University of Pavia, Pavia, 27100, Italy
| | - Viviana Vitolo
- Centro Nazionale di Adroterapia Oncologica, Pavia, 27100, Italy
| | - Francesca Valvo
- Centro Nazionale di Adroterapia Oncologica, Pavia, 27100, Italy
| | - Mario Ciocca
- Centro Nazionale di Adroterapia Oncologica, Pavia, 27100, Italy
| | - Marco Riboldi
- Chair of Experimental Physics - Medical Physics, Ludwig-Maximilians-Universität (LMU), Munich, 80539, Germany
| | - Guido Baroni
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milano, 20133, Italy.,Centro Nazionale di Adroterapia Oncologica, Pavia, 27100, Italy
| |
Collapse
|
19
|
Depauw N, Keyriläinen J, Suilamo S, Warner L, Bzdusek K, Olsen C, Kooy H. MRI-based IMPT planning for prostate cancer. Radiother Oncol 2019; 144:79-85. [PMID: 31734604 DOI: 10.1016/j.radonc.2019.10.010] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2019] [Revised: 10/15/2019] [Accepted: 10/16/2019] [Indexed: 11/15/2022]
Abstract
PURPOSE Treatment planning for proton therapy requires the relative proton stopping power ratio (RSP) information of the patient for accurate dose calculations. RSP are conventionally obtained after mapping of the Hounsfield units (HU) from a calibrated patient computed tomography (CT). One or multiple CT are needed for a given treatment which represents additional, undesired dose to the patient. For prostate cancer, magnetic resonance imaging (MRI) scans are the gold standard for segmentation while offering dose-less imaging. We here quantify the clinical applicability of converted MR images as a substitute for intensity modulated proton therapy (IMPT) treatment of the prostate. METHODS MRCAT (Magnetic Resonance for Calculating ATtenuation) is a Philips-developed technology which produces a synthetic CT image consisting of five HU from a specific set of MRI acquisitions. MRCAT and original planning CT data sets were obtained for ten patients. An IMPT plan was generated on the MRCAT for each patient. Plans were produced such that they fulfill the prostate protocol in use at Massachusetts General Hospital (MGH). The plans were then recomputed onto the nominal planning CT for each patient. Robustness analyses (±5 mm setup shifts and ±3.5 % range uncertainties) were also performed. RESULTS Comparison of MRCAT plans and their recomputation onto the planning CT plan showed excellent agreement. Likewise, dose perturbations due to setup shifts and range uncertainties were well within clinical acceptance demonstrating the clinical viability of the approach. CONCLUSIONS This work demonstrate the clinical acceptability of substituting MR converted RSP images instead of CT for IMPT planning of prostate cancer. This further translates into higher contouring accuracy along with lesser imaging dose.
Collapse
Affiliation(s)
- Nicolas Depauw
- Francis H. Burr Proton Therapy Center, Department of Radiation Oncology, Massachusetts General Hospital (MGH), Boston, USA.
| | - Jani Keyriläinen
- Department of Medical Physics & Department of Oncology and Radiotherapy, Turku University Hospital, Turku, Finland
| | - Sami Suilamo
- Department of Medical Physics & Department of Oncology and Radiotherapy, Turku University Hospital, Turku, Finland
| | | | - Karl Bzdusek
- Philips Healthcare, Philips Radiation Oncology Systems, Fitchburg, USA
| | - Christine Olsen
- Francis H. Burr Proton Therapy Center, Department of Radiation Oncology, Massachusetts General Hospital (MGH), Boston, USA
| | - Hanne Kooy
- Francis H. Burr Proton Therapy Center, Department of Radiation Oncology, Massachusetts General Hospital (MGH), Boston, USA
| |
Collapse
|
20
|
Neppl S, Landry G, Kurz C, Hansen DC, Hoyle B, Stöcklein S, Seidensticker M, Weller J, Belka C, Parodi K, Kamp F. Evaluation of proton and photon dose distributions recalculated on 2D and 3D Unet-generated pseudoCTs from T1-weighted MR head scans. Acta Oncol 2019; 58:1429-1434. [PMID: 31271093 DOI: 10.1080/0284186x.2019.1630754] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
Introduction: The recent developments of magnetic resonance (MR) based adaptive strategies for photon and, potentially for proton therapy, require a fast and reliable conversion of MR images to X-ray computed tomography (CT) values. CT values are needed for photon and proton dose calculation. The improvement of conversion results employing a 3D deep learning approach is evaluated. Material and methods: A database of 89 T1-weighted MR head scans with about 100 slices each, including rigidly registered CTs, was created. Twenty-eight validation patients were randomly sampled, and four patients were selected for application. The remaining patients were used to train a 2D and a 3D U-shaped convolutional neural network (Unet). A stack size of 32 slices was used for 3D training. For all application cases, volumetric modulated arc therapy photon and single-field uniform dose pencil-beam scanning proton plans at four different gantry angles were optimized for a generic target on the CT and recalculated on 2D and 3D Unet-based pseudoCTs. Mean (absolute) error (MAE/ME) and a gradient sharpness estimate were used to quantify the image quality. Three-dimensional gamma and dose difference analyses were performed for photon (gamma criteria: 1%, 1 mm) and proton dose distributions (gamma criteria: 2%, 2 mm). Range (80% fall off) differences for beam's eye view profiles were evaluated for protons. Results: Training 36 h for 1000 epochs in 3D (6 h for 200 epochs in 2D) yielded a maximum MAE of 147 HU (135 HU) for the application patients. Except for one patient gamma pass rates for photon and proton dose distributions were above 96% for both Unets. Slice discontinuities were reduced for 3D training at the cost of sharpness. Conclusions: Image analysis revealed a slight advantage of 2D Unets compared to 3D Unets. Similar dose calculation performance was reached for the 2D and 3D network.
Collapse
Affiliation(s)
- Sebastian Neppl
- Department of Radiation Oncology, University Hospital, LMU Munich, Munich, Germany
- Department of Medical Physics, Faculty of Physics, Ludwig-Maximilians-Universität München (LMU Munich), Garching bei München, Germany
| | - Guillaume Landry
- Department of Radiation Oncology, University Hospital, LMU Munich, Munich, Germany
- Department of Medical Physics, Faculty of Physics, Ludwig-Maximilians-Universität München (LMU Munich), Garching bei München, Germany
| | - Christopher Kurz
- Department of Radiation Oncology, University Hospital, LMU Munich, Munich, Germany
- Department of Medical Physics, Faculty of Physics, Ludwig-Maximilians-Universität München (LMU Munich), Garching bei München, Germany
| | - David C. Hansen
- Department of Medical Physics, Aarhus University Hospital, Aarhus, Denmark
| | - Ben Hoyle
- University Observatory, Faculty of Physics, Ludwig-Maximilians-Universität München (LMU Munich), Munich, Germany
| | - Sophia Stöcklein
- Department of Radiology, University Hospital, LMU Munich, Munich, Germany
| | - Max Seidensticker
- Department of Radiology, University Hospital, LMU Munich, Munich, Germany
| | - Jochen Weller
- University Observatory, Faculty of Physics, Ludwig-Maximilians-Universität München (LMU Munich), Munich, Germany
- Optical and Interpretative Astronomy, Max Planck Institute for Extraterrestrial Physics, Garching bei München, Germany
| | - Claus Belka
- Department of Radiation Oncology, University Hospital, LMU Munich, Munich, Germany
- German Cancer Consortium (DKTK), Partner site Munich, Munich, Germany
| | - Katia Parodi
- Department of Medical Physics, Faculty of Physics, Ludwig-Maximilians-Universität München (LMU Munich), Garching bei München, Germany
| | - Florian Kamp
- Department of Radiation Oncology, University Hospital, LMU Munich, Munich, Germany
| |
Collapse
|
21
|
Nystrom H, Jensen MF, Nystrom PW. Treatment planning for proton therapy: what is needed in the next 10 years? Br J Radiol 2019; 93:20190304. [PMID: 31356107 DOI: 10.1259/bjr.20190304] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022] Open
Abstract
Treatment planning is the process where the prescription of the radiation oncologist is translated into a deliverable treatment. With the complexity of contemporary radiotherapy, treatment planning cannot be performed without a computerized treatment planning system. Proton therapy (PT) enables highly conformal treatment plans with a minimum of dose to tissues outside the target volume, but to obtain the most optimal plan for the treatment, there are a multitude of parameters that need to be addressed. In this review areas of ongoing improvements and research in the field of PT treatment planning are identified and discussed. The main focus is on issues of immediate clinical and practical relevance to the PT community highlighting the needs for the near future but also in a longer perspective. We anticipate that the manual tasks performed by treatment planners in the future will involve a high degree of computational thinking, as many issues can be solved much better by e.g. scripting. More accurate and faster dose calculation algorithms are needed, automation for contouring and planning is required and practical tools to handle the variable biological efficiency in PT is urgently demanded just to mention a few of the expected improvements over the coming 10 years.
Collapse
Affiliation(s)
- Hakan Nystrom
- Danish Centre for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark.,Skandionkliniken, Uppsala, Sweden
| | | | - Petra Witt Nystrom
- Danish Centre for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark.,Skandionkliniken, Uppsala, Sweden
| |
Collapse
|
22
|
Liu Y, Lei Y, Wang Y, Wang T, Ren L, Lin L, McDonald M, Curran WJ, Liu T, Zhou J, Yang X. MRI-based treatment planning for proton radiotherapy: dosimetric validation of a deep learning-based liver synthetic CT generation method. Phys Med Biol 2019; 64:145015. [PMID: 31146267 PMCID: PMC6635951 DOI: 10.1088/1361-6560/ab25bc] [Citation(s) in RCA: 46] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
Magnetic resonance imaging (MRI) has been widely used in combination with computed tomography (CT) radiation therapy because MRI improves the accuracy and reliability of target delineation due to its superior soft tissue contrast over CT. The MRI-only treatment process is currently an active field of research since it could eliminate systematic MR-CT co-registration errors, reduce medical cost, avoid diagnostic radiation exposure, and simplify clinical workflow. The purpose of this work is to validate the application of a deep learning-based method for abdominal synthetic CT (sCT) generation by image evaluation and dosimetric assessment in a commercial proton pencil beam treatment planning system (TPS). This study proposes to integrate dense block into a 3D cycle-consistent generative adversarial networks (cycle GAN) framework in an effort to effectively learn the nonlinear mapping between MRI and CT pairs. A cohort of 21 patients with co-registered CT and MR pairs were used to test the deep learning-based sCT image quality by leave-one-out cross validation. The CT image quality, dosimetric accuracy and the distal range fidelity were rigorously checked, using side-by-side comparison against the corresponding original CT images. The average mean absolute error (MAE) was 72.87 ± 18.16 HU. The relative differences of the statistics of the PTV dose volume histogram (DVH) metrics between sCT and CT were generally less than 1%. Mean 3D gamma analysis passing rate of 1 mm/1%, 2 mm/2%, 3 mm/3% criteria with 10% dose threshold were 90.76% ± 5.94%, 96.98% ± 2.93% and 99.37% ± 0.99%, respectively. The median, mean and standard deviation of absolute maximum range differences were 0.170 cm, 0.186 cm and 0.155 cm. The image similarity, dosimetric and distal range agreement between sCT and original CT suggests the feasibility of further development of an MRI-only workflow for liver proton radiotherapy.
Collapse
Affiliation(s)
- Yingzi Liu
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322
| | - Yang Lei
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322
| | - Yinan Wang
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322
| | - Tonghe Wang
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322
| | - Lei Ren
- Department of Radiation Oncology, Duke University, Durham, NC 27708
| | - Liyong Lin
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322
| | - Mark McDonald
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322
| | - Walter J. Curran
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322
| | - Tian Liu
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322
| | - Jun Zhou
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322
| | - Xiaofeng Yang
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30322
| |
Collapse
|