1
|
Romeo M, Cottone G, D'Oca MC, Bartolotta A, Gallo S, Miraglia R, Gerasia R, Milluzzo G, Romano F, Gagliardo C, Di Martino F, d'Errico F, Marrale M. Diffusion Correction in Fricke Hydrogel Dosimeters: A Deep Learning Approach with 2D and 3D Physics-Informed Neural Network Models. Gels 2024; 10:565. [PMID: 39330168 PMCID: PMC11431587 DOI: 10.3390/gels10090565] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2024] [Revised: 08/21/2024] [Accepted: 08/28/2024] [Indexed: 09/28/2024] Open
Abstract
In this work an innovative approach was developed to address a significant challenge in the field of radiation dosimetry: the accurate measurement of spatial dose distributions using Fricke gel dosimeters. Hydrogels are widely used in radiation dosimetry due to their ability to simulate the tissue-equivalent properties of human tissue, making them ideal for measuring and mapping radiation dose distributions. Among the various gel dosimeters, Fricke gels exploit the radiation-induced oxidation of ferrous ions to ferric ions and are particularly notable due to their sensitivity. The concentration of ferric ions can be measured using various techniques, including magnetic resonance imaging (MRI) or spectrophotometry. While Fricke gels offer several advantages, a significant hurdle to their widespread application is the diffusion of ferric ions within the gel matrix. This phenomenon leads to a blurring of the dose distribution over time, compromising the accuracy of dose measurements. To mitigate the issue of ferric ion diffusion, researchers have explored various strategies such as the incorporation of additives or modification of the gel composition to either reduce the mobility of ferric ions or stabilize the gel matrix. The computational method proposed leverages the power of artificial intelligence, particularly deep learning, to mitigate the effects of ferric ion diffusion that can compromise measurement precision. By employing Physics Informed Neural Networks (PINNs), the method introduces a novel way to apply physical laws directly within the learning process, optimizing the network to adhere to the principles governing ion diffusion. This is particularly advantageous for solving the partial differential equations that describe the diffusion process in 2D and 3D. By inputting the spatial distribution of ferric ions at a given time, along with boundary conditions and the diffusion coefficient, the model can backtrack to accurately reconstruct the original ion distribution. This capability is crucial for enhancing the fidelity of 3D spatial dose measurements, ensuring that the data reflect the true dose distribution without the artifacts introduced by ion migration. Here, multidimensional models able to handle 2D and 3D data were developed and tested against dose distributions numerically evolved in time from 20 to 100 h. The results in terms of various metrics show a significant agreement in both 2D and 3D dose distributions. In particular, the mean square error of the prediction spans the range 1×10-6-1×10-4, while the gamma analysis results in a 90-100% passing rate with 3%/2 mm, depending on the elapsed time, the type of distribution modeled and the dimensionality. This method could expand the applicability of Fricke gel dosimeters to a wider range of measurement tasks, from simple planar dose assessments to intricate volumetric analyses. The proposed technique holds great promise for overcoming the limitations imposed by ion diffusion in Fricke gel dosimeters.
Collapse
Affiliation(s)
- Mattia Romeo
- Department of Physics and Chemistry "Emilio Segrè", University of Palermo, Viale delle Scienze, Edificio 18, I-90128 Palermo, Italy
- Istituto Nazionale di Fisica Nucleare (INFN), Catania Division, Via Santa Sofia, 64, I-95123 Catania, Italy
- Department of Biological, Chemical and Pharmaceutical Sciences and Technologies, Viale delle Scienze, Edificio 16, I-90128 Palermo, Italy
| | - Grazia Cottone
- Department of Physics and Chemistry "Emilio Segrè", University of Palermo, Viale delle Scienze, Edificio 18, I-90128 Palermo, Italy
| | - Maria Cristina D'Oca
- Department of Physics and Chemistry "Emilio Segrè", University of Palermo, Viale delle Scienze, Edificio 18, I-90128 Palermo, Italy
- Istituto Nazionale di Fisica Nucleare (INFN), Catania Division, Via Santa Sofia, 64, I-95123 Catania, Italy
- ATEN Center, University of Palermo, Viale delle Scienze, Edificio 18, I-90128 Palermo, Italy
| | - Antonio Bartolotta
- Department of Physics and Chemistry "Emilio Segrè", University of Palermo, Viale delle Scienze, Edificio 18, I-90128 Palermo, Italy
| | - Salvatore Gallo
- Department of Physics and Astronomy "Ettore Majorana", University of Catania, Via Santa Sofia 64, I-95123 Catania, Italy
| | - Roberto Miraglia
- IRCCS-ISMETT, Radiology Service, Via E. Tricomi, I-90127 Palermo, Italy
| | - Roberta Gerasia
- IRCCS-ISMETT, Radiology Service, Via E. Tricomi, I-90127 Palermo, Italy
| | - Giuliana Milluzzo
- Istituto Nazionale di Fisica Nucleare (INFN), Catania Division, Via Santa Sofia, 64, I-95123 Catania, Italy
| | - Francesco Romano
- Istituto Nazionale di Fisica Nucleare (INFN), Catania Division, Via Santa Sofia, 64, I-95123 Catania, Italy
| | - Cesare Gagliardo
- Department of Biomedicine, Neurosciences and Advanced Diagnostics, University of Palermo, Via del Vespro, 129, I-90127 Palermo, Italy
| | - Fabio Di Martino
- Centro Pisano Ricerca e Implementazione Clinica Flash Radiotherapy (CPFR@CISUP), Presidio S. Chiara, ed. 18 Via Roma 67, I-56126 Pisa, Italy
- Fisica Sanitaria, Azienda Ospedaliero Universitaria Pisa AOUP, ed.18 Via Roma 67, I-56126 Pisa, Italy
- Istituto Nazionale di Fisica Nucleare (INFN), Pisa Division, Largo B. Pontecorvo 3, I-57127 Pisa, Italy
| | - Francesco d'Errico
- School of Engineering, University of Pisa, Largo Lazzarino 1, I-56126 Pisa, Italy
- School of Medicine, Yale University, 333 Cedar St, New Haven, CT 06520, USA
| | - Maurizio Marrale
- Department of Physics and Chemistry "Emilio Segrè", University of Palermo, Viale delle Scienze, Edificio 18, I-90128 Palermo, Italy
- Istituto Nazionale di Fisica Nucleare (INFN), Catania Division, Via Santa Sofia, 64, I-95123 Catania, Italy
- ATEN Center, University of Palermo, Viale delle Scienze, Edificio 18, I-90128 Palermo, Italy
| |
Collapse
|
2
|
Locarno S, Arosio P, Curtoni F, Piazzoni M, Pignoli E, Gallo S. Microscopic and Macroscopic Characterization of Hydrogels Based on Poly(vinyl-alcohol)-Glutaraldehyde Mixtures for Fricke Gel Dosimetry. Gels 2024; 10:172. [PMID: 38534590 DOI: 10.3390/gels10030172] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2024] [Revised: 02/21/2024] [Accepted: 02/22/2024] [Indexed: 03/28/2024] Open
Abstract
In recent decades, hydrogels have emerged as innovative soft materials with widespread applications in the medical and biomedical fields, including drug delivery, tissue engineering, and gel dosimetry. In this work, a comprehensive study of the macroscopic and microscopic properties of hydrogel matrices based on Poly(vinyl-alcohol) (PVA) chemically crosslinked with Glutaraldehyde (GTA) was reported. Five different kinds of PVAs differing in molecular weight and degree of hydrolysis were considered. The local microscopic organization of the hydrogels was studied through the use of the 1H nuclear magnetic resonance relaxometry technique. Various macroscopic properties (gel fraction, water loss, contact angle, swelling degree, viscosity, and Young's Modulus) were investigated with the aim of finding a correlation between them and the features of the hydrogel matrix. Additionally, an optical characterization was performed on all the hydrogels loaded with Fricke solution to assess their dosimetric behavior. The results obtained indicate that the degree of PVA hydrolysis is a crucial parameter influencing the structure of the hydrogel matrix. This factor should be considered for ensuring stability over time, a vital property in the context of potential biomedical applications where hydrogels act as radiological tissue-equivalent materials.
Collapse
Affiliation(s)
- Silvia Locarno
- Dipartimento di Fisica "Aldo Pontremoli", Università degli Studi di Milano, Via G. Celoria 16, 20133 Milano, Italy
- Istituto Nazionale di Fisica Nucleare (INFN), Sezione di Milano, Via G. Celoria 16, 20133 Milano, Italy
| | - Paolo Arosio
- Dipartimento di Fisica "Aldo Pontremoli", Università degli Studi di Milano, Via G. Celoria 16, 20133 Milano, Italy
- Istituto Nazionale di Fisica Nucleare (INFN), Sezione di Milano, Via G. Celoria 16, 20133 Milano, Italy
- Consorzio Interuniversitario Nazionale per la Scienza e Tecnologia dei Materiali (INSTM), 20133 Milano, Italy
| | - Francesca Curtoni
- Dipartimento di Fisica "Aldo Pontremoli", Università degli Studi di Milano, Via G. Celoria 16, 20133 Milano, Italy
| | - Marco Piazzoni
- Dipartimento di Fisica "Aldo Pontremoli", Università degli Studi di Milano, Via G. Celoria 16, 20133 Milano, Italy
- Istituto Nazionale di Fisica Nucleare (INFN), Sezione di Milano, Via G. Celoria 16, 20133 Milano, Italy
| | - Emanuele Pignoli
- Fondazione IRCCS "Istituto Nazionale dei Tumori", Via G. Venezian 1, 20133 Milano, Italy
| | - Salvatore Gallo
- Dipartimento di Fisica "Aldo Pontremoli", Università degli Studi di Milano, Via G. Celoria 16, 20133 Milano, Italy
- Istituto Nazionale di Fisica Nucleare (INFN), Sezione di Milano, Via G. Celoria 16, 20133 Milano, Italy
- Consorzio Interuniversitario Nazionale per la Scienza e Tecnologia dei Materiali (INSTM), 20133 Milano, Italy
| |
Collapse
|
3
|
Lima IS, Silveira MA, Pavoni J, Guidelli JE, Garrido ECS, Baffa O. Assessment of dosimetric sensitivity enhancement of xylenol orange Fricke gel by AuNPs: optical and MR imaging investigation. Phys Med Biol 2023; 68:225011. [PMID: 37852274 DOI: 10.1088/1361-6560/ad04a9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2023] [Accepted: 10/18/2023] [Indexed: 10/20/2023]
Abstract
Metallic nanoparticles, such as gold (Au, Z = 79) and silver (Ag, Z = 47) nanoparticles (AuNPs and AgNPs, respectively), possess strong surface plasmonic resonance (SPR) and high atomic number, which makes them ideal candidates for enhancing dosimeter sensitivity. In this study, we have inserted different mass percentages (from 0 to 0.015 wt%) of AuNPs into a gelatinous Fricke-xylenol-orange (FXO-f) gel matrix and irradiated it with doses ranging from 2 to 32 Gy, using a source of x-ray of low energy with an effective energy of 42 keV. Optical absorption increased significantly; sensitivity gains of up to 50% were achieved for the FXO-f gel matrix containing 0.011 wt% AuNPs. To elucidate the mechanism underlying this increased sensitivity, we also evaluated FXO-f gel matrixes containing AgNPs. AgNPs insertion into the FXO-f gel matrix did not enhance sensitivity, which suggested that the AgNPs plasmonic absorption band and the FXO-f gel matrix absorption band at 441 nm overlapped, to increase absorption even after the gel matrix was irradiated. To visualize the dose distribution, we recorded optical tomography and acquired 3D reconstruction maps. In addition, we analyzed the dose enhancement factor (DEF) by using magnetic resonance images. AuNPs insertion into the FXO-f gel matrix resulted in a DEF gain of 1.37, associated with the photoelectric effect originating from the increased number of free radicals.
Collapse
Affiliation(s)
- I S Lima
- Department of Physics, FFCLRP, University of São Paulo, Av. Bandeirantes 3900, Ribeirão Preto, SP 14040-91, Brazil
| | - M A Silveira
- Department of Physics, FFCLRP, University of São Paulo, Av. Bandeirantes 3900, Ribeirão Preto, SP 14040-91, Brazil
| | - J Pavoni
- Department of Physics, FFCLRP, University of São Paulo, Av. Bandeirantes 3900, Ribeirão Preto, SP 14040-91, Brazil
| | - J E Guidelli
- Department of Physics, FFCLRP, University of São Paulo, Av. Bandeirantes 3900, Ribeirão Preto, SP 14040-91, Brazil
| | - E C S Garrido
- Department of Physics, FFCLRP, University of São Paulo, Av. Bandeirantes 3900, Ribeirão Preto, SP 14040-91, Brazil
| | - O Baffa
- Department of Physics, FFCLRP, University of São Paulo, Av. Bandeirantes 3900, Ribeirão Preto, SP 14040-91, Brazil
| |
Collapse
|
4
|
Chemical Overview of Gel Dosimetry Systems: A Comprehensive Review. Gels 2022; 8:gels8100663. [PMID: 36286165 PMCID: PMC9601373 DOI: 10.3390/gels8100663] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2022] [Revised: 10/10/2022] [Accepted: 10/12/2022] [Indexed: 11/17/2022] Open
Abstract
Advances in radiotherapy technology during the last 25 years have significantly improved both dose conformation to tumors and the preservation of healthy tissues, achieving almost real-time feedback by means of high-precision treatments and theranostics. Owing to this, developing high-performance systems capable of coping with the challenging requirements of modern ionizing radiation is a key issue to overcome the limitations of traditional dosimeters. In this regard, a deep understanding of the physicochemical basis of gel dosimetry, as one of the most promising tools for the evaluation of 3D high-spatial-resolution dose distributions, represents the starting point for developing new and innovative systems. This review aims to contribute thorough descriptions of the chemical processes and interactions that condition gel dosimetry outputs, often phenomenologically addressed, and particularly formulations reported since 2017.
Collapse
|
5
|
De Deene Y. Radiation Dosimetry by Use of Radiosensitive Hydrogels and Polymers: Mechanisms, State-of-the-Art and Perspective from 3D to 4D. Gels 2022; 8:599. [PMID: 36135311 PMCID: PMC9498652 DOI: 10.3390/gels8090599] [Citation(s) in RCA: 16] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2022] [Revised: 09/07/2022] [Accepted: 09/10/2022] [Indexed: 12/22/2022] Open
Abstract
Gel dosimetry was developed in the 1990s in response to a growing need for methods to validate the radiation dose distribution delivered to cancer patients receiving high-precision radiotherapy. Three different classes of gel dosimeters were developed and extensively studied. The first class of gel dosimeters is the Fricke gel dosimeters, which consist of a hydrogel with dissolved ferrous ions that oxidize upon exposure to ionizing radiation. The oxidation results in a change in the nuclear magnetic resonance (NMR) relaxation, which makes it possible to read out Fricke gel dosimeters by use of quantitative magnetic resonance imaging (MRI). The radiation-induced oxidation in Fricke gel dosimeters can also be visualized by adding an indicator such as xylenol orange. The second class of gel dosimeters is the radiochromic gel dosimeters, which also exhibit a color change upon irradiation but do not use a metal ion. These radiochromic gel dosimeters do not demonstrate a significant radiation-induced change in NMR properties. The third class is the polymer gel dosimeters, which contain vinyl monomers that polymerize upon irradiation. Polymer gel dosimeters are predominantly read out by quantitative MRI or X-ray CT. The accuracy of the dosimeters depends on both the physico-chemical properties of the gel dosimeters and on the readout technique. Many different gel formulations have been proposed and discussed in the scientific literature in the last three decades, and scanning methods have been optimized to achieve an acceptable accuracy for clinical dosimetry. More recently, with the introduction of the MR-Linac, which combines an MRI-scanner and a clinical linear accelerator in one, it was shown possible to acquire dose maps during radiation, but new challenges arise.
Collapse
Affiliation(s)
- Yves De Deene
- Liverpool & Macarthur Cancer Therapy Centres, Liverpool, NSW 1871, Australia; or
- Ingham Institute, Liverpool, NSW 2170, Australia
- School of Science, Western Sydney University, Penrith, NSW 2751, Australia
| |
Collapse
|
6
|
How Xylenol Orange and Ferrous Ammonium Sulphate Influence the Dosimetric Properties of PVA–GTA Fricke Gel Dosimeters: A Spectrophotometric Study. Gels 2022; 8:gels8040204. [PMID: 35448105 PMCID: PMC9025870 DOI: 10.3390/gels8040204] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2022] [Revised: 03/17/2022] [Accepted: 03/19/2022] [Indexed: 11/19/2022] Open
Abstract
The development of Fricke gel (FG) dosimeters based on poly(vinyl alcohol) (PVA) as the gelling agent and glutaraldehyde (GTA) as the cross-linker has enabled significant improvements in the dose response and the stability over time of spatial radiation dose distributions. However, a standard procedure for preparing FG in terms of reagent concentrations is still missing in the literature. This study aims to investigate, by means of spectrophotometric analyses, how the sensitivity to the radiation dose and the range of linearity of the dose–response curve of PVA-GTA-FG dosimeters loaded with xylenol orange sodium salt (XO) are influenced by ferrous ammonium sulphate (FAS) and XO concentrations. Moreover, the effect of different concentrations of such compounds on self-oxidation phenomena in the dosimeters was evaluated. PVA-GTA-FG dosimeters were prepared using XO concentrations in the range 0.04–0.80 mM and FAS in the range 0.05–5.00 mM. The optical absorbance properties and the dose response of FG were investigated in the interval 0.0–42.0 Gy. The results demonstrate that the amount of FAS and XO determines both the sensitivity to the absorbed dose and the interval of linearity of the dose–response curve. The study suggests that the best performances of FG dosimeters for spectrophotometric analyses can be obtained using 1.00–0.40 mM and 0.200–0.166 mM concentrations of FAS and XO, respectively.
Collapse
|
7
|
|
8
|
Low-Diffusion Fricke Gel Dosimeters with Core-Shell Structure Based on Spatial Confinement. MATERIALS 2021; 14:ma14143932. [PMID: 34300851 PMCID: PMC8304938 DOI: 10.3390/ma14143932] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/24/2021] [Revised: 07/08/2021] [Accepted: 07/11/2021] [Indexed: 11/17/2022]
Abstract
The diffusion of ferric ions is an important challenge to limit the application of Fricke gel dosimeters in accurate three-dimensional dose verification of modern radiotherapy. In this work, low-diffusion Fricke gel dosimeters, with a core-shell structure based on spatial confinement, were constructed by utilizing microdroplet ultrarapid freezing and coating technology. Polydimethylsiloxane (PDMS), with its excellent hydrophobicity, was coated on the surface of the pellets. The concentration gradient of the ferric ion was realized through shielding half of a Co-60 photon beam field size, and ion diffusion was measured by both ultraviolet-visible spectrophotometry and magnetic resonance imaging. No diffusion occurred between the core-shell pellets, even at 96 h after irradiation, and the diffusion length at the irradiation boundary was limited to the diameter (2-3 mm) of the pellets. Furthermore, Monte Carlo calculations were conducted to study dosimetric properties of the core-shell dosimeter, which indicated that a PDMS shell hardly affected the performance of the dosimeter.
Collapse
|
9
|
Marrale M, d’Errico F. Hydrogels for Three-Dimensional Ionizing-Radiation Dosimetry. Gels 2021; 7:74. [PMID: 34205640 PMCID: PMC8293215 DOI: 10.3390/gels7020074] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2021] [Revised: 06/15/2021] [Accepted: 06/16/2021] [Indexed: 11/28/2022] Open
Abstract
Radiation-sensitive gels are among the most recent and promising developments for radiation therapy (RT) dosimetry. RT dosimetry has the twofold goal of ensuring the quality of the treatment and the radiation protection of the patient. Benchmark dosimetry for acceptance testing and commissioning of RT systems is still based on ionization chambers. However, even the smallest chambers cannot resolve the steep dose gradients of up to 30-50% per mm generated with the most advanced techniques. While a multitude of systems based, e.g., on luminescence, silicon diodes and radiochromic materials have been developed, they do not allow the truly continuous 3D dose measurements offered by radiation-sensitive gels. The gels are tissue equivalent, so they also serve as phantoms, and their response is largely independent of radiation quality and dose rate. Some of them are infused with ferrous sulfate and rely on the radiation-induced oxidation of ferrous ions to ferric ions (Fricke-gels). Other formulations consist of monomers dispersed in a gelatinous medium (Polyacrylamide gels) and rely on radiation-induced polymerization, which creates a stable polymer structure. In both gel types, irradiation causes changes in proton relaxation rates that are proportional to locally absorbed dose and can be imaged using magnetic resonance imaging (MRI). Changes in color and/or opacification of the gels also occur upon irradiation, allowing the use of optical tomography techniques. In this work, we review both Fricke and polyacrylamide gels with emphasis on their chemical and physical properties and on their applications for radiation dosimetry.
Collapse
Affiliation(s)
- Maurizio Marrale
- Department of Physics and Chemistry, “Emilio Segrè” ATeN Center, University of Palermo, 90128 Palermo, Italy
- Istituto Nazionale di Fisica Nucleare (INFN), Sezione di Catania, 95123 Catania, Italy
| | - Francesco d’Errico
- Scuola di Ingegneria, Università degli Studi di Pisa, 56126 Pisa, Italy;
- Istituto Nazionale di Fisica Nucleare (INFN), Sezione di Pisa, 56127 Pisa, Italy
- School of Medicine, Yale University New Haven, CT 06510, USA
| |
Collapse
|
10
|
Dosimetric properties of sulfosalicylic acid-ferrous-polyvinyl alcohol-glutaraldehyde hydrogel dosimeters using magnetic and optical techniques. Radiat Phys Chem Oxf Engl 1993 2020. [DOI: 10.1016/j.radphyschem.2020.109106] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
11
|
Fujino K, Ono K, Hayashi SI, Yasuda H, Akagi Y, Hirokawa Y. Influence of the components of a radiochromic PVA-Iodide gel dosimeter on the thermal and spatial stability. RADIAT MEAS 2020. [DOI: 10.1016/j.radmeas.2020.106338] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|