1
|
Loebner HA, Bertholet J, Mackeprang PH, Volken W, Elicin O, Mueller S, Guyer G, Aebersold DM, Stampanoni MF, Fix MK, Manser P. Robustness analysis of dynamic trajectory radiotherapy and volumetric modulated arc therapy plans for head and neck cancer. Phys Imaging Radiat Oncol 2024; 30:100586. [PMID: 38808098 PMCID: PMC11130727 DOI: 10.1016/j.phro.2024.100586] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2024] [Revised: 04/30/2024] [Accepted: 05/03/2024] [Indexed: 05/30/2024] Open
Abstract
Background and purpose Dynamic trajectory radiotherapy (DTRT) has been shown to improve healthy tissue sparing compared to volumetric arc therapy (VMAT). This study aimed to assess and compare the robustness of DTRT and VMAT treatment-plans for head and neck (H&N) cancer to patient-setup (PS) and machine-positioning uncertainties. Materials and methods The robustness of DTRT and VMAT plans previously created for 46 H&N cases, prescribed 50-70 Gy to 95 % of the planning-target-volume, was assessed. For this purpose, dose distributions were recalculated using Monte Carlo, including uncertainties in PS (translation and rotation) and machine-positioning (gantry-, table-, collimator-rotation and multi-leaf collimator (MLC)). Plan robustness was evaluated by the uncertainties' impact on normal tissue complication probabilities (NTCP) for xerostomia and dysphagia and on dose-volume endpoints. Differences between DTRT and VMAT plan robustness were compared using Wilcoxon matched-pair signed-rank test (α = 5 %). Results Average NTCP for moderate-to-severe xerostomia and grade ≥ II dysphagia was lower for DTRT than VMAT in the nominal scenario (0.5 %, p = 0.01; 2.1 %, p < 0.01) and for all investigated uncertainties, except MLC positioning, where the difference was not significant. Average differences compared to the nominal scenario were ≤ 3.5 Gy for rotational PS (≤ 3°) and machine-positioning (≤ 2°) uncertainties, <7 Gy for translational PS uncertainties (≤ 5 mm) and < 20 Gy for MLC-positioning uncertainties (≤ 5 mm). Conclusions DTRT and VMAT plan robustness to the investigated uncertainties depended on uncertainty direction and location of the structure-of-interest to the target. NTCP remained on average lower for DTRT than VMAT even when considering uncertainties.
Collapse
Affiliation(s)
- Hannes A. Loebner
- Division of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital, and University of Bern, Bern, Switzerland
| | - Jenny Bertholet
- Division of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital, and University of Bern, Bern, Switzerland
| | - Paul-Henry Mackeprang
- Division of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital, and University of Bern, Bern, Switzerland
| | - Werner Volken
- Division of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital, and University of Bern, Bern, Switzerland
| | - Olgun Elicin
- Division of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital, and University of Bern, Bern, Switzerland
| | - Silvan Mueller
- Division of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital, and University of Bern, Bern, Switzerland
| | - Gian Guyer
- Division of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital, and University of Bern, Bern, Switzerland
| | - Daniel M. Aebersold
- Division of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital, and University of Bern, Bern, Switzerland
| | | | - Michael K. Fix
- Division of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital, and University of Bern, Bern, Switzerland
| | - Peter Manser
- Division of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital, and University of Bern, Bern, Switzerland
| |
Collapse
|
2
|
Mendenhall WM, Beitler JJ, Saba NF, Shaha AR, Nuyts S, Strojan P, Bollen H, Cohen O, Smee R, Ng SP, Eisbruch A, Ng WT, Kirwan JM, Ferlito A. Proton Beam Radiation Therapy for Oropharyngeal Squamous Cell Carcinoma. Int J Part Ther 2023; 9:243-252. [PMID: 37169005 PMCID: PMC10166016 DOI: 10.14338/ijpt-22-00030.1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2022] [Accepted: 03/10/2023] [Indexed: 05/13/2023] Open
Abstract
Purpose To discuss the role of proton beam therapy (PBT) in the treatment of patients with oropharyngeal squamous cell carcinoma (OPSCC). Materials and Methods A review of the pertinent literature. Results Proton beam therapy likely results in reduced acute and late toxicity as compared with intensity-modulated radiation therapy (IMRT). The extent of the reduced toxicity, which may be modest, depends on the endpoint and technical factors such as pencil beam versus passive scattered PBT and adaptive replanning. The disease control rates after PBT are likely similar to those after IMRT. Conclusion Proton beam therapy is an attractive option to treat patients with OPSCC. Whether it becomes widely available depends on access.
Collapse
Affiliation(s)
- William M. Mendenhall
- Department of Radiation Oncology, University of Florida College of Medicine, Gainesville, FL, USA
| | - Jonathan J. Beitler
- Harold Alfonds Center for Cancer Care, Maine General Hospital, Augusta, ME, USA
| | - Nabil F. Saba
- Department of Hematology and Medical Oncology, Emory University School of Medicine, Atlanta, GA, USA
| | - Ashok R. Shaha
- Department of Head and Neck Surgery and Oncology, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Sandra Nuyts
- Department of Radiation Oncology, Leuven Cancer Institute, University Hospitals Leuven, KU Leuven - University of Leuven, Leuven, Belgium
- Laboratory of Experimental Radiotherapy, Department of Oncology, University of Leuven, Leuven, Belgium
| | - Primož Strojan
- Department of Radiation Oncology, Institute of Oncology, Ljubljana, Slovenia
| | - Heleen Bollen
- Department of Radiation Oncology, Leuven Cancer Institute, University Hospitals Leuven, KU Leuven - University of Leuven, Leuven, Belgium
| | - Oded Cohen
- Department of Otolaryngology - Head and Neck Surgery and Oncology, Soroka Medical Center, Tel Aviv, Affiliated with Ben Gurion University of the Negev, Beer Sheva, Israel
| | - Robert Smee
- Department of Radiation Oncology, The Prince of Wales Cancer Centre, Sydney, NSW, Australia
| | - Sweet Ping Ng
- Department of Radiation Oncology, Olivia Newton-John Cancer Centre, Austin Health, Melbourne, Australia
| | - Avraham Eisbruch
- Department of Radiation Oncology, University of Michigan Medicine, Ann Arbor, Michigan, USA
| | - Wai Tong Ng
- Department of Clinical Oncology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong, China
| | - Jessica M. Kirwan
- Department of Radiation Oncology, University of Florida College of Medicine, Gainesville, FL, USA
| | - Alfio Ferlito
- Coordinator of the International Head and Neck Scientific Group, Padua, Italy
| |
Collapse
|
3
|
Robbins J, van Herk M, Eiben B, Green A, Vásquez Osorio E. Probabilistic evaluation of plan quality for time-dependent anatomical deformations in head and neck cancer patients. Phys Med 2023; 109:102579. [PMID: 37068428 DOI: 10.1016/j.ejmp.2023.102579] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/18/2022] [Revised: 03/14/2023] [Accepted: 04/05/2023] [Indexed: 04/19/2023] Open
Abstract
PURPOSE In addition to patient set-up uncertainties, anatomical deformations, e.g., weight loss, lead to time-dependent differences between the planned and delivered dose in a radiotherapy course that currently cannot easily be predicted. The aim of this study was to create time-varying prediction models to describe both the average and residual anatomical deformations. METHODS Weekly population-based principal component analysis models were generated from on-treatment cone-beam CT scans (CBCTs) of 30 head and neck cancer patients, with additional data of 35 patients used as a validation cohort. We simulated treatment courses accounting for a) anatomical deformations, b) set-up uncertainties and c) a combination of both. The dosimetric effects of the simulated deformations were compared to a direct dose accumulation based on deformable registration of the CBCT data. RESULTS Set-up uncertainties were seen to have a larger effect on the organ at risk (OAR) doses than anatomical deformations for all OARs except the larynx and the primary CTV. Distributions from simulation results were in good agreement with those of the accumulated dose. CONCLUSIONS We present a novel method of modelling time-varying organ deformations in head and neck cancer. The effect on the OAR doses from these deformations are smaller than the effect of set-up uncertainties for most OARs. These models can, for instance, be used to predict which patients could benefit from adaptive radiotherapy, prior to commencing treatment.
Collapse
Affiliation(s)
- Jennifer Robbins
- The University of Manchester, Division of Cancer Sciences, Faculty of Biology, Medicine and Health, Manchester, United Kingdom.
| | - Marcel van Herk
- The University of Manchester, Division of Cancer Sciences, Faculty of Biology, Medicine and Health, Manchester, United Kingdom
| | - Björn Eiben
- Joint Department of Physics, Institute of Cancer Research and Royal Marsden NHS Foundation Trust, London, United Kingdom; Centre for Medical Image Computing, Radiotherapy Image Computing Group, Department of Medical Physics and Biomedical Engineering University College London, London, United Kingdom
| | - Andrew Green
- The University of Manchester, Division of Cancer Sciences, Faculty of Biology, Medicine and Health, Manchester, United Kingdom
| | - Eliana Vásquez Osorio
- The University of Manchester, Division of Cancer Sciences, Faculty of Biology, Medicine and Health, Manchester, United Kingdom.
| |
Collapse
|
4
|
Chang S, Liu G, Zhao L, Zheng W, Yan D, Chen P, Li X, Deraniyagala R, Stevens C, Grills I, Chinnaiyan P, Li X, Ding X. Introduce a rotational robust optimization framework for spot-scanning proton arc (SPArc) therapy. Phys Med Biol 2022; 68. [PMID: 36546347 DOI: 10.1088/1361-6560/aca874] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2022] [Accepted: 12/02/2022] [Indexed: 12/03/2022]
Abstract
Objective. Proton dosimetric uncertainties resulting from the patient's daily setup errors in rotational directions exist even with advanced image-guided radiotherapy techniques. Thus, we developed a new rotational robust optimization SPArc algorithm (SPArcrot) to mitigate the dosimetric impact of the rotational setup error in Raystation ver. 6.02 (RaySearch Laboratory AB, Stockholm, Sweden).Approach.The initial planning CT was rotated ±5° simulating the worst-case setup error in the roll direction. The SPArcrotuses a multi-CT robust optimization framework by taking into account of such rotational setup errors. Five cases representing different disease sites were evaluated. Both SPArcoriginaland SPArcrotplans were generated using the same translational robust optimized parameters. To quantitatively investigate the mitigation effect from the rotational setup errors, all plans were recalculated using a series of pseudo-CT with rotational setup error (±1°/±2°/±3°/±5°). Dosimetric metrics such as D98% of CTV, and 3D gamma analysis were used to assess the dose distribution changes in the target and OARs.Main results.The magnitudes of dosimetric changes in the targets due to rotational setup error were significantly reduced by the SPArcrotcompared to SPArc in all cases. The uncertainties of the max dose to the OARs, such as brainstem, spinal cord and esophagus were significantly reduced using SPArcrot. The uncertainties of the mean dose to the OARs such as liver and oral cavity, parotid were comparable between the two planning techniques. The gamma passing rate (3%/3 mm) was significantly improved for CTV of all tumor sites through SPArcrot.Significance.Rotational setup error is one of the major issues which could lead to significant dose perturbations. SPArcrotplanning approach can consider such rotational error from patient setup or gantry rotation error by effectively mitigating the dose uncertainties to the target and in the adjunct series OARs.
Collapse
Affiliation(s)
- Sheng Chang
- Department of Radiation Oncology, Wuhan University, Renmin Hospital, Wuhan, 430060 Hubei Province, People's Republic of China.,Department of Radiation Oncology, Corewell Health William Beaumont University Hospital, Royal Oak, MI 48074, United States of America
| | - Gang Liu
- Department of Radiation Oncology, Corewell Health William Beaumont University Hospital, Royal Oak, MI 48074, United States of America.,Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430023, People's Republic of China
| | - Lewei Zhao
- Department of Radiation Oncology, Corewell Health William Beaumont University Hospital, Royal Oak, MI 48074, United States of America
| | - Weili Zheng
- Department of Radiation Oncology, Corewell Health William Beaumont University Hospital, Royal Oak, MI 48074, United States of America
| | - Di Yan
- Department of Radiation Oncology, Corewell Health William Beaumont University Hospital, Royal Oak, MI 48074, United States of America
| | - Peter Chen
- Department of Radiation Oncology, Corewell Health William Beaumont University Hospital, Royal Oak, MI 48074, United States of America
| | - Xiangpan Li
- Department of Radiation Oncology, Wuhan University, Renmin Hospital, Wuhan, 430060 Hubei Province, People's Republic of China
| | - Rohan Deraniyagala
- Department of Radiation Oncology, Corewell Health William Beaumont University Hospital, Royal Oak, MI 48074, United States of America
| | - Craig Stevens
- Department of Radiation Oncology, Corewell Health William Beaumont University Hospital, Royal Oak, MI 48074, United States of America
| | - Inga Grills
- Department of Radiation Oncology, Corewell Health William Beaumont University Hospital, Royal Oak, MI 48074, United States of America
| | - Prakash Chinnaiyan
- Department of Radiation Oncology, Corewell Health William Beaumont University Hospital, Royal Oak, MI 48074, United States of America
| | - Xiaoqiang Li
- Department of Radiation Oncology, Corewell Health William Beaumont University Hospital, Royal Oak, MI 48074, United States of America
| | - Xuanfeng Ding
- Department of Radiation Oncology, Corewell Health William Beaumont University Hospital, Royal Oak, MI 48074, United States of America
| |
Collapse
|
5
|
Duan X, Chen L, Zhou Y. Evaluation of target autocrop function in nasopharyngeal carcinoma SIB IMRT plan. Phys Eng Sci Med 2021; 45:97-105. [PMID: 34846672 DOI: 10.1007/s13246-021-01082-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2021] [Accepted: 11/15/2021] [Indexed: 10/19/2022]
Abstract
A new target autocrop function was introduced in the Varian Eclipse™ treatment planning software (version 15.5 above) (Lohynská in Klin Onkol 33(4):288-294, 2020). The study aimed to evaluate this new target autocrop impact on nasopharyngeal carcinoma (NPC) plan quality and delivery efficiency. Randomly 66 approved NPC simultaneous integrated boost (SIB) intensity-modulated radiation therapy (IMRT) treatment plans were retrospectively studied. The manual cropping-based plans served as reference and were designed using sliding-window IMRT. Reference plans were re-optimized with identical plan parameters following the institutional clinical protocol, except for the redundant optimization objective of the manual cropping targets deleted. Additionally, each target within 5 mm of another had one minimum objective at 100% volume and one maximum objective at 0% volume for the autocrop plans. Plan quality was assessed based on selected parameters, including TCP (tumor control probability), NTCP (normal tissue complication probability), conformality index (CI), homogeneity index (HI), and dose-volume characteristics. Additionally, the delivery efficiency, the total plan treatment time defined as a sum of monitor units (MUs) for each treated field, and delivery accuracy, γ passing rate of treatment plan quality assurance (QA) also were compared. Both the manual cropping plans and the autocrop plans could be approved by an experienced oncologist. Overall, the autocrop plans could provide approximately a 13% reduction in linac MU while maintaining comparable plan quality, radiobiological ranking, and accuracy to the manual cropping plans. The new target autocrop tip facilitated the SIB IMRT plans for nasopharyngeal cancer patients. The autocrop could guarantee the quality and delivery accuracy of the radiotherapy plan and improved the planning efficiency, treatment efficiency, and reduced machine wear and tear. It was a promising tool for optimal plan selection for NPC SIB IMRT.
Collapse
Affiliation(s)
- Xiaojuan Duan
- Institute of Cancer Research, Xinqiao Hospital, ARMY Medical University, Chongqing, 400037, China
| | - Lu Chen
- Institute of Cancer Research, Xinqiao Hospital, ARMY Medical University, Chongqing, 400037, China
| | - Yibing Zhou
- Institute of Cancer Research, Xinqiao Hospital, ARMY Medical University, Chongqing, 400037, China.
| |
Collapse
|
6
|
Paganetti H, Botas P, Sharp GC, Winey B. Adaptive proton therapy. Phys Med Biol 2021; 66:10.1088/1361-6560/ac344f. [PMID: 34710858 PMCID: PMC8628198 DOI: 10.1088/1361-6560/ac344f] [Citation(s) in RCA: 44] [Impact Index Per Article: 14.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2021] [Accepted: 10/28/2021] [Indexed: 12/25/2022]
Abstract
Radiation therapy treatments are typically planned based on a single image set, assuming that the patient's anatomy and its position relative to the delivery system remains constant during the course of treatment. Similarly, the prescription dose assumes constant biological dose-response over the treatment course. However, variations can and do occur on multiple time scales. For treatment sites with significant intra-fractional motion, geometric changes happen over seconds or minutes, while biological considerations change over days or weeks. At an intermediate timescale, geometric changes occur between daily treatment fractions. Adaptive radiation therapy is applied to consider changes in patient anatomy during the course of fractionated treatment delivery. While traditionally adaptation has been done off-line with replanning based on new CT images, online treatment adaptation based on on-board imaging has gained momentum in recent years due to advanced imaging techniques combined with treatment delivery systems. Adaptation is particularly important in proton therapy where small changes in patient anatomy can lead to significant dose perturbations due to the dose conformality and finite range of proton beams. This review summarizes the current state-of-the-art of on-line adaptive proton therapy and identifies areas requiring further research.
Collapse
Affiliation(s)
- Harald Paganetti
- Department of Radiation Oncology, Physics Division, Massachusetts General Hospital, Boston, Massachusetts, United States of America
- Harvard Medical School, Boston, Massachusetts, United States of America
| | - Pablo Botas
- Department of Radiation Oncology, Physics Division, Massachusetts General Hospital, Boston, Massachusetts, United States of America
- Harvard Medical School, Boston, Massachusetts, United States of America
- Foundation 29 of February, Pozuelo de Alarcón, Madrid, Spain
| | - Gregory C Sharp
- Department of Radiation Oncology, Physics Division, Massachusetts General Hospital, Boston, Massachusetts, United States of America
- Harvard Medical School, Boston, Massachusetts, United States of America
| | - Brian Winey
- Department of Radiation Oncology, Physics Division, Massachusetts General Hospital, Boston, Massachusetts, United States of America
- Harvard Medical School, Boston, Massachusetts, United States of America
| |
Collapse
|
7
|
Taasti VT, Jeong J, Jackson A, Deasy JO. A theoretical investigation of adequate range uncertainty margins in proton treatment planning to preserve tumor control probability. Acta Oncol 2019; 58:1446-1450. [PMID: 31241385 DOI: 10.1080/0284186x.2019.1627415] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
Background: Proton dose distributions are sensitive to range uncertainties, resulting in margins added to ensure adequate tumor control probability (TCP). We investigated the required margin and dose shape needed to ensure adequate TCP, for representative tumor cell distributions in the clinical target volume (CTV). Material and methods: A mechanistic tumor response model, validated for lung tumors, was used to estimate TCP. The tumor cell distribution ( ρ ) was assumed to decrease exponentially in the CTV with decay parameter λ toward the outer border ( xCTVmax ). It was investigated if a gradual dose fall-off could reduce the dose to normal tissues outside the CTV, while achieving adequate TCP. For various values of xCTVmax and λ, we derived adequate uniform dose margins ( m ), coupled to linear dose fall-off regions ( Δx, Δxnom=Δx-0.9 cm), that ensured TCP>TCPlimit, while delivering the least mean dose outside the CTV. To account for variabilities in patients and tumor types, variable probabilities ( p ) of finding tumor cells in the non-GTV part of the CTV for a given patient were also tested. Dose from a single beam or two opposing beams was simulated under the influence of a typical stopping power ratio uncertainty of 3.5%. Results: For large λ and xCTVmax, a dose distribution with a shallower dose fall-off ( Δx>0 ) was advantageous, and m could be smaller than xCTVmax. In the case of small xCTVmax values, however, a conventional dose distribution ( Δx=0 ) would generally perform better. For no CTV, m=0.4 cm in the case of two opposing beams, while it was 0.7 cm for a single beam, however, for two opposing beams Δx=1.2 cm ( Δxnom=0.3 cm), while it was zero for a single beam. Conclusion: The details of the underlying cancer cell distribution characteristics do impact the adequate dose arrangements, and for opposing beams a non-conventional dose distribution shape is often advantageous.
Collapse
Affiliation(s)
- Vicki T. Taasti
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Jeho Jeong
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Andrew Jackson
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Joseph O. Deasy
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| |
Collapse
|