Fletcher JG, Inoue A, Bratt A, Horst KK, Koo CW, Rajiah PS, Baffour FI, Ko JP, Remy-Jardin M, McCollough CH, Yu L. Photon-counting CT in Thoracic Imaging: Early Clinical Evidence and Incorporation Into Clinical Practice. Radiology 2024; 310:e231986. [PMID: 38501953 DOI: 10.1148/radiol.231986] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/20/2024]
Abstract
Photon-counting CT (PCCT) is an emerging advanced CT technology that differs from conventional CT in its ability to directly convert incident x-ray photon energies into electrical signals. The detector design also permits substantial improvements in spatial resolution and radiation dose efficiency and allows for concurrent high-pitch and high-temporal-resolution multienergy imaging. This review summarizes (a) key differences in PCCT image acquisition and image reconstruction compared with conventional CT; (b) early evidence for the clinical benefit of PCCT for high-spatial-resolution diagnostic tasks in thoracic imaging, such as assessment of airway and parenchymal diseases, as well as benefits of high-pitch and multienergy scanning; (c) anticipated radiation dose reduction, depending on the diagnostic task, and increased utility for routine low-dose thoracic CT imaging; (d) adaptations for thoracic imaging in children; (e) potential for further quantitation of thoracic diseases; and (f) limitations and trade-offs. Moreover, important points for conducting and interpreting clinical studies examining the benefit of PCCT relative to conventional CT and integration of PCCT systems into multivendor, multispecialty radiology practices are discussed.
Collapse
Affiliation(s)
- Joel G Fletcher
- From the Department of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN, 55905 (J.G.F., A.I., A.B., K.K.H., C.W.K., P.S.R., F.I.B., C.H.M., L.Y.); Department of Radiology, Shiga University of Medical Science, Shiga, Japan (A.I.); Department of Radiology, NYU Grossman School of Medicine, NYU Langone Health, New York, NY (J.P.K.); and IMALLIANCE-Haut-de-France, Valenciennes, France (M.R.J.)
| | - Akitoshi Inoue
- From the Department of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN, 55905 (J.G.F., A.I., A.B., K.K.H., C.W.K., P.S.R., F.I.B., C.H.M., L.Y.); Department of Radiology, Shiga University of Medical Science, Shiga, Japan (A.I.); Department of Radiology, NYU Grossman School of Medicine, NYU Langone Health, New York, NY (J.P.K.); and IMALLIANCE-Haut-de-France, Valenciennes, France (M.R.J.)
| | - Alex Bratt
- From the Department of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN, 55905 (J.G.F., A.I., A.B., K.K.H., C.W.K., P.S.R., F.I.B., C.H.M., L.Y.); Department of Radiology, Shiga University of Medical Science, Shiga, Japan (A.I.); Department of Radiology, NYU Grossman School of Medicine, NYU Langone Health, New York, NY (J.P.K.); and IMALLIANCE-Haut-de-France, Valenciennes, France (M.R.J.)
| | - Kelly K Horst
- From the Department of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN, 55905 (J.G.F., A.I., A.B., K.K.H., C.W.K., P.S.R., F.I.B., C.H.M., L.Y.); Department of Radiology, Shiga University of Medical Science, Shiga, Japan (A.I.); Department of Radiology, NYU Grossman School of Medicine, NYU Langone Health, New York, NY (J.P.K.); and IMALLIANCE-Haut-de-France, Valenciennes, France (M.R.J.)
| | - Chi Wan Koo
- From the Department of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN, 55905 (J.G.F., A.I., A.B., K.K.H., C.W.K., P.S.R., F.I.B., C.H.M., L.Y.); Department of Radiology, Shiga University of Medical Science, Shiga, Japan (A.I.); Department of Radiology, NYU Grossman School of Medicine, NYU Langone Health, New York, NY (J.P.K.); and IMALLIANCE-Haut-de-France, Valenciennes, France (M.R.J.)
| | - Prabhakar Shantha Rajiah
- From the Department of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN, 55905 (J.G.F., A.I., A.B., K.K.H., C.W.K., P.S.R., F.I.B., C.H.M., L.Y.); Department of Radiology, Shiga University of Medical Science, Shiga, Japan (A.I.); Department of Radiology, NYU Grossman School of Medicine, NYU Langone Health, New York, NY (J.P.K.); and IMALLIANCE-Haut-de-France, Valenciennes, France (M.R.J.)
| | - Francis I Baffour
- From the Department of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN, 55905 (J.G.F., A.I., A.B., K.K.H., C.W.K., P.S.R., F.I.B., C.H.M., L.Y.); Department of Radiology, Shiga University of Medical Science, Shiga, Japan (A.I.); Department of Radiology, NYU Grossman School of Medicine, NYU Langone Health, New York, NY (J.P.K.); and IMALLIANCE-Haut-de-France, Valenciennes, France (M.R.J.)
| | - Jane P Ko
- From the Department of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN, 55905 (J.G.F., A.I., A.B., K.K.H., C.W.K., P.S.R., F.I.B., C.H.M., L.Y.); Department of Radiology, Shiga University of Medical Science, Shiga, Japan (A.I.); Department of Radiology, NYU Grossman School of Medicine, NYU Langone Health, New York, NY (J.P.K.); and IMALLIANCE-Haut-de-France, Valenciennes, France (M.R.J.)
| | - Martine Remy-Jardin
- From the Department of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN, 55905 (J.G.F., A.I., A.B., K.K.H., C.W.K., P.S.R., F.I.B., C.H.M., L.Y.); Department of Radiology, Shiga University of Medical Science, Shiga, Japan (A.I.); Department of Radiology, NYU Grossman School of Medicine, NYU Langone Health, New York, NY (J.P.K.); and IMALLIANCE-Haut-de-France, Valenciennes, France (M.R.J.)
| | - Cynthia H McCollough
- From the Department of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN, 55905 (J.G.F., A.I., A.B., K.K.H., C.W.K., P.S.R., F.I.B., C.H.M., L.Y.); Department of Radiology, Shiga University of Medical Science, Shiga, Japan (A.I.); Department of Radiology, NYU Grossman School of Medicine, NYU Langone Health, New York, NY (J.P.K.); and IMALLIANCE-Haut-de-France, Valenciennes, France (M.R.J.)
| | - Lifeng Yu
- From the Department of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN, 55905 (J.G.F., A.I., A.B., K.K.H., C.W.K., P.S.R., F.I.B., C.H.M., L.Y.); Department of Radiology, Shiga University of Medical Science, Shiga, Japan (A.I.); Department of Radiology, NYU Grossman School of Medicine, NYU Langone Health, New York, NY (J.P.K.); and IMALLIANCE-Haut-de-France, Valenciennes, France (M.R.J.)
| |
Collapse
|
2
|
McCollough CH, Rajendran K, Baffour FI, Diehn FE, Ferrero A, Glazebrook KN, Horst KK, Johnson TF, Leng S, Mileto A, Rajiah PS, Schmidt B, Yu L, Flohr TG, Fletcher JG. Clinical applications of photon counting detector CT. Eur Radiol 2023; 33:5309-5320. [PMID: 37020069 PMCID: PMC10330165 DOI: 10.1007/s00330-023-09596-y] [Citation(s) in RCA: 12] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2022] [Revised: 12/13/2022] [Accepted: 02/03/2023] [Indexed: 04/07/2023]
Abstract
The X-ray detector is a fundamental component of a CT system that determines the image quality and dose efficiency. Until the approval of the first clinical photon-counting-detector (PCD) system in 2021, all clinical CT scanners used scintillating detectors, which do not capture information about individual photons in the two-step detection process. In contrast, PCDs use a one-step process whereby X-ray energy is converted directly into an electrical signal. This preserves information about individual photons such that the numbers of X-ray in different energy ranges can be counted. Primary advantages of PCDs include the absence of electronic noise, improved radiation dose efficiency, increased iodine signal and the ability to use lower doses of iodinated contrast material, and better spatial resolution. PCDs with more than one energy threshold can sort the detected photons into two or more energy bins, making energy-resolved information available for all acquisitions. This allows for material classification or quantitation tasks to be performed in conjunction with high spatial resolution, and in the case of dual-source CT, high pitch, or high temporal resolution acquisitions. Some of the most promising applications of PCD-CT involve imaging of anatomy where exquisite spatial resolution adds clinical value. These include imaging of the inner ear, bones, small blood vessels, heart, and lung. This review describes the clinical benefits observed to date and future directions for this technical advance in CT imaging. KEY POINTS: • Beneficial characteristics of photon-counting detectors include the absence of electronic noise, increased iodine signal-to-noise ratio, improved spatial resolution, and full-time multi-energy imaging. • Promising applications of PCD-CT involve imaging of anatomy where exquisite spatial resolution adds clinical value and applications requiring multi-energy data simultaneous with high spatial and/or temporal resolution. • Future applications of PCD-CT technology may include extremely high spatial resolution tasks, such as the detection of breast micro-calcifications, and quantitative imaging of native tissue types and novel contrast agents.
Collapse
Affiliation(s)
- Cynthia H McCollough
- Department of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA.
| | - Kishore Rajendran
- Department of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA
| | - Francis I Baffour
- Department of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA
| | - Felix E Diehn
- Department of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA
| | - Andrea Ferrero
- Department of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA
| | - Katrina N Glazebrook
- Department of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA
| | - Kelly K Horst
- Department of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA
| | - Tucker F Johnson
- Department of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA
| | - Shuai Leng
- Department of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA
| | - Achille Mileto
- Department of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA
| | | | - Bernhard Schmidt
- Computed Tomography, Siemens Healthineers, Siemensstrasse 3, Forchheim, 91301, Germany
| | - Lifeng Yu
- Department of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA
| | - Thomas G Flohr
- Computed Tomography, Siemens Healthineers, Siemensstrasse 3, Forchheim, 91301, Germany
| | - Joel G Fletcher
- Department of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA
| |
Collapse
|
3
|
Dobrolinska MM, van der Werf NR, van der Bie J, de Groen J, Dijkshoorn M, Booij R, Budde RPJ, Greuter MJW, van Straten M. Radiation dose optimization for photon-counting CT coronary artery calcium scoring for different patient sizes: a dynamic phantom study. Eur Radiol 2023; 33:4668-4675. [PMID: 36729174 PMCID: PMC10290002 DOI: 10.1007/s00330-023-09434-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2022] [Revised: 10/19/2022] [Accepted: 01/07/2023] [Indexed: 02/03/2023]
Abstract
PURPOSE To systematically assess the radiation dose reduction potential of coronary artery calcium (CAC) assessments with photon-counting computed tomography (PCCT) by changing the tube potential for different patient sizes with a dynamic phantom. METHODS A hollow artery, containing three calcifications of different densities, was translated at velocities corresponding to 0, < 60, 60-75, and > 75 beats per minute within an anthropomorphic phantom. Extension rings were used to simulate average- and large -sized patients. PCCT scans were made with the reference clinical protocol (tube potential of 120 kilovolt (kV)), and with 70, 90, Sn100, Sn140, and 140 kV at identical image quality levels. All acquisitions were reconstructed at a virtual monoenergetic energy level of 70 keV. For each calcification, Agatston scores and contrast-to-noise ratios (CNR) were determined, and compared to the reference with Wilcoxon signed-rank tests, with p < 0.05 indicating significant differences. RESULTS A decrease in radiation dose (22%) was achieved at Sn100 kV for the average-sized phantom. For the large phantom, Sn100 and Sn140 kV resulted in a decrease in radiation doses of 19% and 3%, respectively. Irrespective of CAC density, Sn100 and 140 kVp did not result in significantly different CNR. Only at Sn100 kV were there no significant differences in Agatston scores for all CAC densities, heart rates, and phantom sizes. CONCLUSION PCCT at tube voltage of 100 kV with added tin filtration and reconstructed at 70 keV enables a ≥ 19% dose reduction compared to 120 kV, independent of phantom size, CAC density, and heart rate. KEY POINTS • Photon-counting CT allows for reduced radiation dose acquisitions (up to 19%) for coronary calcium assessment by reducing tube voltage while reconstructing at a normal monoE level of 70 keV. • Tube voltage reduction is possible for medium and large patient sizes, without affecting the Agatston score outcome.
Collapse
Affiliation(s)
- Magdalena M Dobrolinska
- Department of Radiology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
- Division of Cardiology and Structural Heart Diseases, Medical University of Silesiain , Katowice, Katowice, Poland
- Department of Radiology & Nuclear Medicine, Erasmus University Medical Center, Rotterdam, The Netherlands
| | - Niels R van der Werf
- Department of Radiology & Nuclear Medicine, Erasmus University Medical Center, Rotterdam, The Netherlands.
| | - Judith van der Bie
- Department of Radiology & Nuclear Medicine, Erasmus University Medical Center, Rotterdam, The Netherlands
| | - Joël de Groen
- Department of Radiology & Nuclear Medicine, Erasmus University Medical Center, Rotterdam, The Netherlands
| | - Marcel Dijkshoorn
- Department of Radiology & Nuclear Medicine, Erasmus University Medical Center, Rotterdam, The Netherlands
| | - Ronald Booij
- Department of Radiology & Nuclear Medicine, Erasmus University Medical Center, Rotterdam, The Netherlands
| | - Ricardo P J Budde
- Department of Radiology & Nuclear Medicine, Erasmus University Medical Center, Rotterdam, The Netherlands
| | - Marcel J W Greuter
- Department of Radiology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
- Department of Robotics and Mechatronics, University of Twente, Enschede, The Netherlands
| | - Marcel van Straten
- Department of Radiology & Nuclear Medicine, Erasmus University Medical Center, Rotterdam, The Netherlands
| |
Collapse
|
4
|
Sawall S. [New contrast agents for photon-counting computed tomography]. RADIOLOGIE (HEIDELBERG, GERMANY) 2023:10.1007/s00117-023-01135-6. [PMID: 37069237 DOI: 10.1007/s00117-023-01135-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 03/03/2023] [Indexed: 04/19/2023]
Abstract
BACKGROUND The introduction of energy-selective photon-counting detectors into clinical practice represents the next milestone in computed tomography (CT). In addition to significantly higher resolution, these detectors allow the implicit acquisition of dual or multispectral data in a single measurement through the use of typically freely selectable thresholds. This capability reignited the interest in new contrast agents based on heavy elements, so-called high‑z elements, for clinical CT. OBJECTIVE The present article aims to investigate the potential suitability of different chemical elements as contrast agents and to discuss possible clinical applications, for example, K‑edge imaging or simultaneous application of different contrast agents. CONCLUSION First preclinical experiments as well as experiments in large animals could demonstrate potential advantages of contrast agents based on heavy elements. For example, such contrast agents promise a significant increase in image contrast compared to conventional iodine-based agents.
Collapse
Affiliation(s)
- Stefan Sawall
- Röntgenbildgebung und CT (E025), Deutsches Krebsforschungszentrum (DKFZ), Heidelberg, Deutschland.
- Medizinische Fakultät, Universität Heidelberg, Heidelberg, Deutschland.
| |
Collapse
|
5
|
An introduction to photon-counting detector CT (PCD CT) for radiologists. Jpn J Radiol 2023; 41:266-282. [PMID: 36255601 PMCID: PMC9974724 DOI: 10.1007/s11604-022-01350-6] [Citation(s) in RCA: 10] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2022] [Accepted: 10/01/2022] [Indexed: 10/24/2022]
Abstract
The basic performance of photon-counting detector computed tomography (PCD CT) is superior to conventional CT (energy-integrating detector CT: EID CT) because its spatial- and contrast resolution of soft tissues is higher, and artifacts are reduced. Because the X-ray photon energy separation is better with PCD CT than conventional EID-based dual-energy CT, it has the potential to improve virtual monochromatic- and virtual non-contrast images, material decomposition including quantification of the iodine distribution, and K-edge imaging. Therefore, its clinical applicability may be increased. Although the image quality of PCD CT scans is superior to that of EID CT currently, further improvement may be possible. The introduction of iterative image reconstruction and reconstruction with deep convolutional neural networks will be useful.
Collapse
|
6
|
Tin-filtered 100 kV Ultra-low-dose Abdominal CT for Calculi Detection in the Urinary Tract: A Comparative Study of 510 Cases. Acad Radiol 2022; 30:1033-1038. [PMID: 35963837 DOI: 10.1016/j.acra.2022.07.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2022] [Revised: 07/14/2022] [Accepted: 07/14/2022] [Indexed: 11/23/2022]
Abstract
OBJECTIVES For detection of urinary calculi, unenhanced low-dose computed tomography is the method of choice, outperforming radiography and ultrasound. This retrospective monocentric study aims to compare a clinically established, dedicated low-dose imaging protocol for detection of urinary calculi with an ultra-low-dose protocol employing tin prefiltration at a standardized tube voltage of 100 kVp. METHODS Two study arms included a total of 510 cases. The "low-dose group" was comprised of 290 individuals (96 women; age 49 ± 16 years; BMI 27.23 ± 5.60 kg/m2). The "ultra-low-dose group" with Sn100 kVp consisted of 220 patients (84 women; age 47 ± 17 years; BMI 26.82 ± 5.62 kg/m2). No significant difference was ascertained for comparison of age (p = 0.132) and BMI (p = 0.207) between cohorts. For quantitative assessment of image quality, image noise was assessed. RESULTS No significant difference regarding frequency of calculi detection was found between groups (p = 0.596). Compared to the low-dose protocol (3.08 mSv; IQR 2.22-4.02 mSv), effective dose was reduced by 62.35% with the ultra-low-dose protocol employing spectral shaping (1.16 mSv; IQR 0.89-1.54 mSv). Image noise was calculated at 18.90 (IQR 17.39-21.20) for the low-dose protocol and at 18.69 (IQR 17.30-21.62) for the ultra-low-dose spectral shaping protocol. No significant difference was ascertained for comparison between groups (p = 0.793). CONCLUSION For urinary calculi detection, ultra-low-dose scans utilizing spectral shaping by means of tin prefiltration at 100 kVp allow for considerable dose reduction of up to 62% over conventional low-dose CT without compromising image quality.
Collapse
|
7
|
van der Werf NR, Rodesch PA, Si-Mohamed S, van Hamersvelt RW, Greuter MJW, Leiner T, Boussel L, Willemink MJ, Douek P. Improved coronary calcium detection and quantification with low-dose full field-of-view photon-counting CT: a phantom study. Eur Radiol 2022; 32:3447-3457. [PMID: 34997284 DOI: 10.1007/s00330-021-08421-8] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2021] [Revised: 08/31/2021] [Accepted: 10/17/2021] [Indexed: 12/19/2022]
Abstract
OBJECTIVE The aim of the current study was to systematically assess coronary artery calcium (CAC) detection and quantification for spectral photon-counting CT (SPCCT) in comparison to conventional CT and, in addition, to evaluate the possibility of radiation dose reduction. METHODS Routine clinical CAC CT protocols were used for data acquisition and reconstruction of two CAC containing cylindrical inserts which were positioned within an anthropomorphic thorax phantom. In addition, data was acquired at 50% lower radiation dose by reducing tube current, and slice thickness was decreased. Calcifications were considered detectable when three adjacent voxels exceeded the CAC scoring threshold of 130 Hounsfield units (HU). Quantification of CAC (as volume and mass score) was assessed by comparison with known physical quantities. RESULTS In comparison with CT, SPCCT detected 33% and 7% more calcifications for the small and large phantoms, respectively. At reduced radiation dose and reduced slice thickness, small phantom CAC detection increased by 108% and 150% for CT and SPCCT, respectively. For the large phantom size, noise levels interfered with CAC detection. Although comparable between CT and SPCCT, routine protocols CAC quantification showed large deviations (up to 134%) from physical CAC volume. At reduced radiation dose and slice thickness, physical volume overestimations decreased to 96% and 72% for CT and SPCCT, respectively. In comparison with volume scores, mass score deviations from physical quantities were smaller. CONCLUSION CAC detection on SPCCT is superior to CT, and was even preserved at a reduced radiation dose. Furthermore, SPCCT allows for improved physical volume estimation. KEY POINTS • In comparison with conventional CT, increased coronary artery calcium detection (up to 156%) for spectral photon-counting CT was found, even at 50% radiation dose reduction. • Spectral photon-counting CT can more accurately measure physical volumes than conventional CT, especially at reduced slice thickness and for high-density coronary artery calcium. • For both conventional and spectral photon-counting CT, reduced slice thickness reconstructions result in more accurate physical mass approximation.
Collapse
Affiliation(s)
- N R van der Werf
- Department of Radiology, University Medical Center Utrecht, Utrecht, The Netherlands. .,Department of Radiology & Nuclear Medicine, Erasmus University Medical Center, Rotterdam, The Netherlands.
| | - P A Rodesch
- Louis Pradel Cardiology Hospital, Hospices Civils de Lyon, Lyon, France.,Univ Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, Lyon, France
| | - S Si-Mohamed
- Louis Pradel Cardiology Hospital, Hospices Civils de Lyon, Lyon, France.,Univ Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, Lyon, France
| | - R W van Hamersvelt
- Department of Radiology, University Medical Center Utrecht, Utrecht, The Netherlands
| | - M J W Greuter
- Department of Radiology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
| | - T Leiner
- Department of Radiology, University Medical Center Utrecht, Utrecht, The Netherlands
| | - L Boussel
- Louis Pradel Cardiology Hospital, Hospices Civils de Lyon, Lyon, France.,Univ Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, Lyon, France
| | - M J Willemink
- Department of Radiology, Stanford University School of Medicine, Stanford, CA, USA
| | - P Douek
- Louis Pradel Cardiology Hospital, Hospices Civils de Lyon, Lyon, France.,Univ Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, Lyon, France
| |
Collapse
|
8
|
Jiang F, Fu X, Kuang K, Fan D. Artificial Intelligence Algorithm-Based Differential Diagnosis of Crohn's Disease and Ulcerative Colitis by CT Image. COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE 2022; 2022:3871994. [PMID: 35419083 PMCID: PMC9001074 DOI: 10.1155/2022/3871994] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/11/2022] [Revised: 02/18/2022] [Accepted: 02/24/2022] [Indexed: 01/21/2023]
Abstract
The aim of this study was to investigate the effect of low-dose CT enterography (CTE) based on modified guided image filtering (GIF) algorithm in the differential diagnosis of ulcerative colitis (UC) and Crohn's disease (CD). Methods. One hundred and twenty patients with suspected diagnosis of IBD were studied. They were randomly divided into control group (routine CT examination) and observation group (low-dose CTE examination based on improved GIF algorithm), with 60 cases in each group. Comprehensive diagnosis was used as the standard to assess the diagnostic effect. Results. (1) The peak signal-to-noise ratio (PSNR) (26.02 dB) and structural similarity (SSIM) (0.8921) of the algorithm were higher than those of GIF (17.22 dB/0.8491), weighted guided image filtering (WGIF) (23.78 dB/0.8489), and gradient domain guided image filtering (GGIF) (23.77 dB/0.7567) (P < 0.05); (2) the diagnostic sensitivity (91.49%), specificity (92.31%), accuracy (91.67%), positive predictive value (97.73%), and negative predictive value (75%) of the observation group were higher than those of the control group (P < 0.05); the sensitivity and specificity of CTE in the diagnosis of UD and CD were 96.77% and 81.25% and 98.33% and 93.33%, respectively (P < 0.05); there were significant differences in symmetrical intestinal wall thickening and smooth serosal surface between UD and CD (P < 0.05). Conclusion. (1) The improved GIF algorithm has a more effective application value in the denoising processing of low-dose CT images and can better improve the image quality; (2) the accuracy of CTE in the diagnosis of IBD is high, and CTE is of great value in the differential diagnosis of UD and CD.
Collapse
Affiliation(s)
- Fangyun Jiang
- Department of Gastroenterology, The Third Affiliated Hospital, Hengyang Medical School, University of South China, Hengyang, Hunan 421001, China
| | - Xiaoping Fu
- Department of Neurosurgery, The Third Affiliated Hospital, Hengyang Medical School, University of South China, Hengyang, Hunan 421001, China
| | - Kai Kuang
- Department of Gastroenterology, The Third Affiliated Hospital, Hengyang Medical School, University of South China, Hengyang, Hunan 421001, China
| | - Dan Fan
- Department of Gastroenterology, The Third Affiliated Hospital, Hengyang Medical School, University of South China, Hengyang, Hunan 421001, China
| |
Collapse
|
9
|
Lee Y. Performance analysis of improved hybrid median filter applied to X-ray computed tomography images obtained with high-resolution photon-counting CZT detector: a pilot study. NUCLEAR ENGINEERING AND TECHNOLOGY 2022. [DOI: 10.1016/j.net.2022.03.025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
10
|
Ren L, Huber N, Rajendran K, Fletcher JG, McCollough CH, Yu L. Dual-Contrast Biphasic Liver Imaging With Iodine and Gadolinium Using Photon-Counting Detector Computed Tomography: An Exploratory Animal Study. Invest Radiol 2022; 57:122-129. [PMID: 34411033 PMCID: PMC8732294 DOI: 10.1097/rli.0000000000000815] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE The aims of this study were to develop a single-scan dual-contrast protocol for biphasic liver imaging with 2 intravenous contrast agents (iodine and gadolinium) and to evaluate its effectiveness in an exploratory swine study using a photon-counting detector computed tomography (PCD-CT) system. MATERIALS AND METHODS A dual-contrast CT protocol was developed for PCD-CT to simultaneously acquire 2 phases of liver contrast enhancement, with the late arterial phase enhanced by 1 contrast agent (iodine-based) and the portal venous phase enhanced by the other (gadolinium-based). A gadolinium contrast bolus (gadobutrol: 64 mL, 8 mL/s) and an iodine contrast bolus (iohexol: 40 mL, 5 mL/s) were intravenously injected in the femoral vein of a healthy domestic swine, with the second injection initiated after 17 seconds from the beginning of the first injection; PCD-CT image acquisition was performed 12 seconds after the beginning of the iodine contrast injection. A convolutional neural network (CNN)-based denoising technique was applied to PCD-CT images to overcome the inherent noise magnification issue in iodine/gadolinium decomposition task. Iodine and gadolinium material maps were generated using a 3-material decomposition method in image space. A set of contrast samples (mixed iodine and gadolinium) was attached to the swine belly; quantitative accuracy of material decomposition in these inserts between measured and true concentrations was calculated using root mean square error. An abdominal radiologist qualitatively evaluated the delineation of arterial and venous vasculatures in the swine liver using iodine and gadolinium maps obtained using the dual-contrast PCD-CT protocol. RESULTS The iodine and gadolinium samples attached to the swine were quantified with root mean square error values of 0.75 mg/mL for iodine and 0.45 mg/mL for gadolinium from the contrast material maps derived from the denoised PCD-CT images. Hepatic arteries containing iodine and veins containing gadolinium in the swine liver could be clearly visualized. Compared with the original images, better distinctions between 2 liver phases were achieved using CNN denoising, with approximately 60% to 80% noise reduction in contrast material maps acquired with the denoised PCD-CT images compared with the original images. CONCLUSIONS Simultaneous biphasic liver imaging in a single multienergy PCD-CT acquisition using a dual-contrast (iodine and gadolinium) injection protocol and CNN denoising was demonstrated in a swine study, where the enhanced hepatic arteries (containing iodine) and the enhanced hepatic veins (containing gadolinium) could be clearly visualized and delineated in the swine liver.
Collapse
Affiliation(s)
- Liqiang Ren
- From the Department of Radiology, Mayo Clinic, Rochester, MN
| | | | | | | | | | | |
Collapse
|
11
|
Zhou Z, Ren L, Rajendran K, Diehn FE, Fletcher JG, McCollough CH, Yu L. Simultaneous dual-contrast imaging using energy-integrating-detector multi-energy CT: An in vivo feasibility study. Med Phys 2022; 49:1458-1467. [PMID: 35018658 DOI: 10.1002/mp.15448] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2021] [Revised: 12/12/2021] [Accepted: 12/17/2021] [Indexed: 11/11/2022] Open
Abstract
PURPOSE To demonstrate the feasibility of simultaneous dual-contrast imaging in a large animal using a newly developed dual-source energy-integrating-detector (EID) based multi-energy computed tomography (MECT) system. METHODS Two imaging tasks that may have potential clinical applications were investigated: head/neck (HN) CT angiography (CTA)/CT venography (CTV) with iodine and gadolinium, and small bowel imaging with iodine and bismuth in domestic swine. Dual-source x-ray beam configurations of 70 kV+Au120/Sn120 kV and 70 kV+Au140/Sn140 kV were used for the HN-CTA/CTV and small bowel imaging studies, respectively. A test bolus scan was performed for each study. The ROIs in the carotid artery and jugular vein for HN-CTA/CTV imaging and abdominal aorta for small bowel imaging were used to determine the time-attenuation curves, based on which the timing for contrast injection and the CT scan was determined. In the HN-CTA/CTV study, a MECT scan was performed at the time point corresponding to the optimal arterial enhancement by iodine and the optimal venous enhancement by gadolinium. In the small bowel imaging study, A MECT scan was performed at the optimal time point to simultaneously capture the mesenteric arterial enhancement of iodine and the enteric enhancement of bismuth. Image-based material decomposition was performed to decompose different materials for each study. To quantitatively characterize contrast material separation and misclassification, two ROIs on left common carotid artery and left internal jugular vein in HN-CTA/CTV imaging and three ROIs on superior mesenteric artery, ileal lumen, and collapsed ileum (ileal wall) in small bowel imaging were placed to measure the mean concentration values and the standard deviations. RESULTS In the HN-CTA/CTV study, common carotid arteries containing iodine and internal/external jugular veins containing gadolinium were clearly delineated from each other. Fine vessels such as cephalic veins and branches of external jugular veins were noticeable but clear visualization was hindered by image noise in gadolinium-specific (CTV) images, as reviewed by a neuro radiologist. In the small bowel imaging study, the mesenteric arteries and collapsed bowel wall containing iodine and the small bowel loops containing bismuth were clearly distinctive from each other in the iodine- and bismuth-specific images after material decomposition, as reviewed by an abdominal radiologist. Quantitative analyses showed that the misclassifications between the two contrast materials were less than 1.7 mg/mL and 0.1 mg/mL for CTA/CTV and small bowel imaging studies, respectively. CONCLUSIONS Feasibility of simultaneous CTA/CTV imaging in head and neck with iodine and gadolinium and simultaneous imaging of arterial and enteric phases of small bowel with iodine and bismuth, using a dual-source EID-MECT system, was demonstrated in a swine study. Compared to iodine and gadolinium in CTA/CTV, better delineation and classification of iodine and bismuth in small bowel imaging were achieved mainly due to wider separation between the corresponding two K-edge energies. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Zhongxing Zhou
- Department of Radiology, Mayo Clinic, Rochester, MN, 55905, US
| | - Liqiang Ren
- Department of Radiology, Mayo Clinic, Rochester, MN, 55905, US
| | | | - Felix E Diehn
- Department of Radiology, Mayo Clinic, Rochester, MN, 55905, US
| | - Joel G Fletcher
- Department of Radiology, Mayo Clinic, Rochester, MN, 55905, US
| | | | - Lifeng Yu
- Department of Radiology, Mayo Clinic, Rochester, MN, 55905, US
| |
Collapse
|
12
|
Rajagopal JR, Farhadi F, Solomon J, Sahbaee P, Saboury B, Pritchard WF, Jones EC, Samei E. Comparison of Low Dose Performance of Photon-Counting and Energy Integrating CT. Acad Radiol 2021; 28:1754-1760. [PMID: 32855051 PMCID: PMC7902731 DOI: 10.1016/j.acra.2020.07.033] [Citation(s) in RCA: 31] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2020] [Revised: 07/23/2020] [Accepted: 07/26/2020] [Indexed: 12/14/2022]
Abstract
RATIONALE AND OBJECTIVES The purpose of this study was to investigate the potential of photon-counting CT (PCCT) to improve quantitative image quality for low dose imaging compared to energy-integrating detector CT (EID CT). MATERIALS AND METHODS An investigational scanner (Siemens, Germany) with PCCT and EID CT subsystems was used to compare image quality performance at four dose levels: 1.7, 2, 4, 6 mGy CTDIvol, all at or below current dose values used for conventional abdominal CT. A CT quality control phantom with a homogeneous section for noise measurements and a section with cylindrical inserts of air (-910 HU), polystyrene (50 HU), acrylic (205 HU), and Teflon (1000 HU) was imaged and characterized in terms of noise, resolution, contrast-to-noise ratio (CNR), and detectability index. A second phantom with a 30 cm diameter was also imaged containing iodine solutions ranging from 0.125 to 8 mg I/mL. CNR of the iodine vials was computed as a function of CT dose and iodine concentration. RESULTS With resolution unaffected by dose in both PCCT and EID CT, PCCT images exhibited 22.1-24.0% improvement in noise across dose levels evaluated. This noise improvement translated into a 29-41% improvement in CNR and 20-36% improvement in detectability index. For iodine contrast, PCCT images had a higher CNR for all combinations of iodine contrast and dose evaluated. CONCLUSION For the conditions studied, PCCT exhibited superior image quality compared to EID CT. For iodine detection, PCCT offered a notable advantage with improved CNR at all doses and iodine concentration levels.
Collapse
Affiliation(s)
- Jayasai R Rajagopal
- Carl E. Ravin Advanced Imaging Laboratories, Medical Physics Graduate Program, Department of Radiology, Duke University Medical Center, Durham, North Carolina; Radiology and Imaging Sciences, Clinical Center, National Institutes of Health, 10 Center Drive, Room 1C351, Bethesda, MD 20892.
| | - Faraz Farhadi
- Radiology and Imaging Sciences, Clinical Center, National Institutes of Health, 10 Center Drive, Room 1C351, Bethesda, MD 20892
| | - Justin Solomon
- Carl E. Ravin Advanced Imaging Laboratories, Medical Physics Graduate Program, Clinical Imaging Physics Group, Department of Radiology, Duke University Medical Center, Durham, North Carolina
| | | | - Babak Saboury
- Radiology and Imaging Sciences, Clinical Center, National Institutes of Health, 10 Center Drive, Room 1C351, Bethesda, MD 20892
| | - William F Pritchard
- Center for Interventional Oncology, Radiology and Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, Maryland
| | - Elizabeth C Jones
- Radiology and Imaging Sciences, Clinical Center, National Institutes of Health, 10 Center Drive, Room 1C351, Bethesda, MD 20892
| | - Ehsan Samei
- Carl E. Ravin Advanced Imaging Laboratories, Medical Physics Graduate Program, Clinical Imaging Physics Group, Department of Radiology, Duke University Medical Center, Durham, North Carolina.
| |
Collapse
|
13
|
Miao Z, Yang H, Liu B, Li W. Correlation analysis of epicardial adipose tissue volume quantified by computed tomography images and coronary heart disease under optimized reconstruction algorithm. Pak J Med Sci 2021; 37:1677-1681. [PMID: 34712305 PMCID: PMC8520373 DOI: 10.12669/pjms.37.6-wit.4882] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2021] [Revised: 06/12/2021] [Accepted: 07/05/2021] [Indexed: 11/17/2022] Open
Abstract
Objectives: This paper was aimed to explore the adoption value of low-dose computed tomography (CT) imaging based on optimized ordered subset expectation maximization (OSEM) reconstruction algorithm in the correlation analysis between epicardial adipose tissue (EAT) volume and coronary heart disease (CHD). Methods: A total of 110 patients with CHD were selected for CT angiography (CTA) and coronary arteriography (CAG) examinations from October 2017 to October 2019. The predictive value of EAT for CHD was analyzed via receiver operating characteristic (ROC) curve. Results: The results showed that the iteration time and error of the improved OSEM reconstruction algorithm were better than that of MLEM algorithm under the same number of iterations. Age, smoking, hypertension, diabetes, and EAT in control group were obviously lower in contrast to those in CHD group (P<0.05). EAT in control group was (124.50±26.72) mL, and EAT in the CHD group was (159.41±38.51) mL. EAT (B=0.023, P=0.003) was an independent risk factor for CHD, which was suggested by Multiple linear regression analysis. Moreover, EAT was a risk factor for CHD, and was positively correlated with the degree and NSCV. Conclusion: The optimized OSEM algorithm was used to improve the reconstruction quality of low-dose CT images and used in quantitative measurement of epicardial fat volume. Results showed EAT was an independent risk factor for CHD, and was positively correlated with the number of coronary lesions and Gensini score. It was of great value for the prediction of CHD.
Collapse
Affiliation(s)
- Zhenwei Miao
- Zhenwei Miao, Master of Medicine. Department of Radiology, Tianjin Baodi Hospital, Tianjin City 301800, China
| | - Hongyan Yang
- Hongyan Yang, Bachelor's Degrees. Department of Nursing, Tianjin Baodi Hospital, Tianjin City 301800, China
| | - Bofen Liu
- Bofen Liu, Bachelor's Degrees. Department of Nursing, Tianjin Baodi Hospital, Tianjin City 301800, China
| | - Wengui Li
- Wengui Li, Bachelor's Degrees. Department of Radiology, Tianjin Baodi Hospital, Tianjin City 301800, China
| |
Collapse
|
14
|
Ren L, Allmendinger T, Halaweish A, Schmidt B, Flohr T, McCollough CH, Yu L. Energy-integrating-detector multi-energy CT: Implementation and a phantom study. Med Phys 2021; 48:4857-4871. [PMID: 33988849 PMCID: PMC8455428 DOI: 10.1002/mp.14943] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2020] [Revised: 04/09/2021] [Accepted: 04/30/2021] [Indexed: 11/08/2022] Open
Abstract
PURPOSE Multi-energy computed tomography (MECT) has a great potential to enable many novel clinical applications such as simultaneous multi-contrast imaging. The purpose of this study was to implement triple-beam MECT on a traditional energy-integrating-detector (EID) CT platform (EID-MECT). METHODS This was accomplished by mounting a z-axis split-filter (0.05 mm Au, 0.6 mm Sn) on Tube A of a dual-source EID CT scanner. With the two split x-ray beams from Tube A and the third beam from Tube B, three beams with different x-ray spectra can be simultaneously acquired. With Tube B operated at 70 or 80 kV and Tube A at 120 or 140 kV, four different triple-beam configurations were calibrated for MECT measurements: 70/Au120/Sn120, 80/Au120/Sn120, 70/Au140/Sn140, and 80/Au140/Sn140 kV. Iodine (I), gadolinium (Gd), bismuth (Bi) samples, and their mixtures were prepared for 2 three-material-decomposition tasks and 1 four-material-decomposition task. For each task, samples were placed in a water phantom and scanned using each of the four triple-beam configurations. For comparison, the same phantom was also scanned using three other dual-energy CT (DECT) or MECT technologies: twin-beam DECT (TB-DECT), dual-source DECT (DS-DECT), and photon-counting-detector CT (PCD-CT), all with optimal x-ray spectrum settings and at equal volume CT dose index (CTDIvol). The phantom for four-material decomposition (I/Gd/Bi/Water imaging) was scanned using the PCD-CT only (140 kV with 25, 50, 75, and 90 keV). Image-based material decomposition was performed to acquire material-specific images, on which the mean basis material concentrations and noise levels were measured and compared across all triple-beam configurations in EID-MECT and various DECT/MECT systems. RESULTS The optimal triple-beam configuration was task-dependent with 70/Au120/Sn120, 70/Au140/Sn140, and 70/Au120/Sn120 kV for I/Gd/Water, I/Bi/Water, and I/Gd/Bi/Water material decomposition tasks, respectively. At equal radiation dose level, EID-MECT provided comparable or better quantification accuracy in material-specific images for all three material decomposition tasks, compared to EID-based DECT and PCD-CT systems. In terms of noise level comparison, EID-MECT-derived material-specific images showed lower noise levels than TB-DECT and DS-DECT, but slightly higher than that from PCD-CT in I/Gd/Water imaging. For I/Bi/Water imaging, EID-MECT showed a comparable noise level to DS-DECT, and a much lower noise level than TB-DECT and PCD-CT in all material-specific images. For the four-material decomposition task involving I/Gd/Bi/Water, the bismuth-specific image derived from EID-MECT was slightly noisier, but both iodine- and gadolinium-specific images showed much lower noise levels in comparison to PCD-CT. CONCLUSIONS For the first time, an EID-based MECT system that can simultaneously acquire three x-ray spectra measurements was implemented on a clinical scanner, which demonstrated comparable or better imaging performance than existing DECT and MECT systems.
Collapse
Affiliation(s)
- Liqiang Ren
- Department of Radiology, Mayo Clinic, Rochester, MN, US
| | | | | | | | | | | | - Lifeng Yu
- Department of Radiology, Mayo Clinic, Rochester, MN, US
| |
Collapse
|
15
|
Lee O, Rajendran K, Polster C, Stierstorfer K, Kappler S, Leng S, McCollough CH, Taguchi K. X-Ray Transmittance Modeling-Based Material Decomposition Using a Photon-Counting Detector CT System. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2021. [DOI: 10.1109/trpms.2020.3028363] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
16
|
Wang AS, Pelc NJ. Spectral Photon Counting CT: Imaging Algorithms and Performance Assessment. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2021; 5:453-464. [PMID: 35419500 PMCID: PMC9000208 DOI: 10.1109/trpms.2020.3007380] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/27/2023]
Abstract
Photon counting x-ray detectors (PCDs) with spectral capabilities have the potential to revolutionize computed tomography (CT) for medical imaging. The ideal PCD provides accurate energy information for each incident x-ray, and at high spatial resolution. This information enables material-specific imaging, enhanced radiation dose efficiency, and improved spatial resolution in CT images. In practice, PCDs are affected by non-idealities, including limited energy resolution, pulse pileup, and cross talk due to charge sharing, K-fluorescence, and Compton scattering. In order to maximize their performance, PCDs must be carefully designed to reduce these effects and then later account for them during correction and post-acquisition steps. This review article examines algorithms for using PCDs in spectral CT applications, including how non-idealities impact image quality. Performance assessment metrics that account for spatial resolution and noise such as the detective quantum efficiency (DQE) can be used to compare different PCD designs, as well as compare PCDs with conventional energy integrating detectors (EIDs). These methods play an important role in enhancing spectral CT images and assessing the overall performance of PCDs.
Collapse
Affiliation(s)
- Adam S Wang
- Departments of Radiology and, by courtesy, Electrical Engineering, Stanford University, Stanford, CA 94305 USA
| | - Norbert J Pelc
- Department of Radiology, Stanford University, Stanford, CA 94305 USA
| |
Collapse
|
17
|
Hsieh SS, Leng S, Rajendran K, Tao S, McCollough CH. Photon Counting CT: Clinical Applications and Future Developments. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2021; 5:441-452. [PMID: 34485784 PMCID: PMC8409241 DOI: 10.1109/trpms.2020.3020212] [Citation(s) in RCA: 46] [Impact Index Per Article: 15.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
The use of a photon counting detector in CT (PCD CT) is currently the subject of intense investigation and development. In this review article, we will describe potential clinical applications of this technology with a particular focus on the experience of our own institution with a prototype PCD CT scanner. PCDs have three primary advantages over conventional, energy integrating detectors (EIDs): they provide spectral information without need for a dedicated dual energy protocol; they are immune to electronic noise; and they can be made very high resolution without significant compromises to quantum efficiency. These advantages translate into several clinical applications. Metal artifacts, beam hardening artifacts, and noise streaks from photon starvation can be better mitigated using PCD CT. Certain incidental findings can be better characterized using the spectral information from PCD CT. High-contrast, high-resolution structures such as the temporal bone can be better visualized using PCD CT and at greatly reduced dose. We also discuss new possibilities on the horizon, including new contrast agents, and how anticipated improvements in PCD CT will translate to performance in these applications.
Collapse
Affiliation(s)
- Scott S Hsieh
- Department of Radiology at the Mayo Clinic, Rochester MN 55905 USA
| | - Shuai Leng
- Department of Radiology at the Mayo Clinic, Rochester MN 55905 USA
| | | | - Shengzhen Tao
- Department of Radiology at the Mayo Clinic, Rochester MN 55905 USA
| | | |
Collapse
|
18
|
Sawall S, Amato C, Klein L, Wehrse E, Maier J, Kachelrieß M. Toward molecular imaging using spectral photon-counting computed tomography? Curr Opin Chem Biol 2021; 63:163-170. [PMID: 34051510 DOI: 10.1016/j.cbpa.2021.04.002] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2021] [Accepted: 04/07/2021] [Indexed: 12/22/2022]
Abstract
Molecular imaging is a valuable tool in drug discovery and development, early screening and diagnosis of diseases, and therapy assessment among others. Although many different imaging modalities are in use today, molecular imaging with computed tomography (CT) is still challenging owing to its low sensitivity and soft tissue contrast compared with other modalities. Recent technical advances, particularly the introduction of spectral photon-counting detectors, might allow overcoming these challenges. Herein, the fundamentals and recent advances in CT relevant to molecular imaging are reviewed and potential future preclinical and clinical applications are highlighted. The review concludes with a discussion of potential future advancements of CT for molecular imaging.
Collapse
Affiliation(s)
- Stefan Sawall
- Division of X-Ray Imaging and CT, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, Heidelberg, 69120, Baden-Württemberg, Germany; Medical Faculty, Ruprecht-Karls-University Heidelberg, Im Neuenheimer Feld 672, Heidelberg, 69120, Baden-Württemberg, Germany.
| | - Carlo Amato
- Division of X-Ray Imaging and CT, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, Heidelberg, 69120, Baden-Württemberg, Germany; Medical Faculty, Ruprecht-Karls-University Heidelberg, Im Neuenheimer Feld 672, Heidelberg, 69120, Baden-Württemberg, Germany
| | - Laura Klein
- Division of X-Ray Imaging and CT, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, Heidelberg, 69120, Baden-Württemberg, Germany; Physical Faculty, Ruprecht-Karls-University Heidelberg, Im Neuenheimer Feld 226, Heidelberg, 69120, Baden-Württemberg, Germany
| | - Eckhard Wehrse
- Division of Radiology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, Heidelberg, 69120, Baden-Württemberg, Germany; Medical Faculty, Ruprecht-Karls-University Heidelberg, Im Neuenheimer Feld 672, Heidelberg, 69120, Baden-Württemberg, Germany
| | - Joscha Maier
- Division of X-Ray Imaging and CT, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, Heidelberg, 69120, Baden-Württemberg, Germany
| | - Marc Kachelrieß
- Division of X-Ray Imaging and CT, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, Heidelberg, 69120, Baden-Württemberg, Germany; Medical Faculty, Ruprecht-Karls-University Heidelberg, Im Neuenheimer Feld 672, Heidelberg, 69120, Baden-Württemberg, Germany
| |
Collapse
|
19
|
Simultaneous Dual-Contrast Imaging of Small Bowel With Iodine and Bismuth Using Photon-Counting-Detector Computed Tomography: A Feasibility Animal Study. Invest Radiol 2021; 55:688-694. [PMID: 32530868 DOI: 10.1097/rli.0000000000000687] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
OBJECTIVES Dual-energy and multienergy computed tomography (DECT/MECT) has the potential to simultaneously visualize two contrast agents in the small bowel: arterial enhancement of iodine in the bowel wall and enteric enhancement of bismuth in the bowel lumen. The purpose of this study was to explore its feasibility in a swine study using a research whole-body photon-counting-detector (PCD) computed tomography (CT) system. MATERIALS AND METHODS A phantom study was initially performed to evaluate the quantification accuracy of iodine and bismuth separation from a single PCD-CT scan, which also served as the calibration reference for material decomposition of in vivo swine PCD-CT data. In the animal study, a test bolus scan was first performed to determine the time-attenuation curve for the arterial enhancement, based on which the timing of the PCD-CT dual-contrast scan was determined. A 600 mL homogeneous bismuth-saline solution (180 mL Pepto-Bismol + 420 mL normal saline) was orally administered to the pig using esophageal intubation. Approximately 1 hour after bismuth administration, 40 mL iodine contrast (Omnipaque 350, 5 mL/s) was injected intravenously. A PCD-CT scan was performed 13 seconds after the initiation of the contrast injection to simultaneously capture the arterial enhancement of iodine and the enteric enhancement of bismuth. To provide optimal material separation and quantification, all PCD-CT scans in both phantom and animal studies were operated at 140 kV with 4 energy thresholds of 25, 50, 75, and 90 keV. RESULTS Using a generic image-based material decomposition method, the iodine and bismuth samples were successfully delineated and quantified in the phantom images with a root-mean-square-error of 1.32 mg/mL in iodine measurement and 0.64 mg/mL in bismuth measurement. In the pig study, the enhancing bowel wall containing iodine and the small bowel loop containing bismuth were not differentiable in the original PCD-CT images. However, they were clearly distinctive from each other in the iodine- and bismuth-specific images after material decomposition, as reviewed by an abdominal radiologist. In addition, quantitative analysis showed that the misclassification between the two contrast materials was less than 1.0 mg/mL. CONCLUSIONS Our study demonstrated the feasibility of simultaneous imaging of iodine and bismuth in small bowel of swine using PCD-CT.
Collapse
|
20
|
Sandstedt M, Marsh J, Rajendran K, Gong H, Tao S, Persson A, Leng S, McCollough C. Improved coronary calcification quantification using photon-counting-detector CT: an ex vivo study in cadaveric specimens. Eur Radiol 2021; 31:6621-6630. [PMID: 33713174 DOI: 10.1007/s00330-021-07780-6] [Citation(s) in RCA: 36] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2020] [Revised: 01/19/2021] [Accepted: 02/12/2021] [Indexed: 12/19/2022]
Abstract
OBJECTIVES To compare the accuracy of coronary calcium quantification of cadaveric specimens imaged from a photon-counting detector (PCD)-CT and an energy-integrating detector (EID)-CT. METHODS Excised coronary specimens were scanned on a PCD-CT scanner, using both the PCD and EID subsystems. The scanning and reconstruction parameters for EID-CT and PCD-CT were matched: 120 kV, 9.3-9.4 mGy CTDIvol, and a quantitative kernel (D50). PCD-CT images were also reconstructed using a sharper kernel (D60). Scanning the same specimens using micro-CT served as a reference standard for calcified volumes. Calcifications were segmented with a half-maximum thresholding technique. Segmented calcified volume differences were analyzed using the Friedman test and post hoc pairwise Wilcoxon signed rank test with the Bonferroni correction. Image noise measurements were compared between EID-CT and PCD-CT with a repeated-measures ANOVA test and post hoc pairwise comparison with the Bonferroni correction. A p < 0.05 was considered statistically significant. RESULTS The volume measurements in 12/13 calcifications followed a similar trend: EID-D50 > PCD-D50 > PCD-D60 > micro-CT. The median calcified volumes in EID-D50, PCD-D50, PCD-D60, and micro-CT were 22.1 (IQR 10.2-64.8), 21.0 (IQR 9.0-56.5), 18.2 (IQR 8.3-49.3), and 14.6 (IQR 5.1-42.4) mm3, respectively (p < 0.05 for all pairwise comparisons). The average image noise in EID-D50, PCD-D50, and PCD-D60 was 60.4 (± 3.5), 56.0 (± 4.2), and 113.6 (± 8.5) HU, respectively (p < 0.01 for all pairwise comparisons). CONCLUSION The PCT-CT system quantified coronary calcifications more accurately than EID-CT, and a sharp PCD-CT kernel further improved the accuracy. The PCD-CT images exhibited lower noise than the EID-CT images. KEY POINTS • High spatial resolution offered by PCD-CT reduces partial volume averaging and consequently leads to better morphological depiction of coronary calcifications. • Improved quantitative accuracy for coronary calcification volumes could be achieved using high-resolution PCD-CT compared to conventional EID-CT. • PCD-CT images exhibit lower image noise than conventional EID-CT at matched radiation dose and reconstruction kernel.
Collapse
Affiliation(s)
- Mårten Sandstedt
- Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden.,Department of Radiology and Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden
| | - Jeffrey Marsh
- Department of Radiology, Mayo Clinic, Rochester, MN, USA
| | | | - Hao Gong
- Department of Radiology, Mayo Clinic, Rochester, MN, USA
| | - Shengzhen Tao
- Department of Radiology, Mayo Clinic, Rochester, MN, USA
| | - Anders Persson
- Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden.,Department of Radiology and Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden.,Department of Clinical Science, Intervention and Technology, Karolinska Institutet, Stockholm, Sweden
| | - Shuai Leng
- Department of Radiology, Mayo Clinic, Rochester, MN, USA
| | | |
Collapse
|
21
|
Ren L, Rajendran K, McCollough CH, Yu L. Quantitative accuracy and dose efficiency of dual-contrast imaging using dual-energy CT: a phantom study. Med Phys 2019; 47:441-456. [PMID: 31705664 DOI: 10.1002/mp.13912] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2019] [Revised: 10/28/2019] [Accepted: 10/31/2019] [Indexed: 12/17/2022] Open
Abstract
PURPOSE To evaluate the quantitative accuracy and dose efficiency of simultaneous imaging of two contrast agents using dual-energy computed tomography (DECT), two imaging tasks each representing one potential clinical application were investigated in a phantom study: biphasic liver imaging with iodine and gadolinium, and small bowel imaging with iodine and bismuth. METHODS To separate and quantify mixtures of two contrast agents using a single DECT scan, mixed iodine and gadolinium samples were prepared with the contrast enhancement values corresponding to the late arterial (iodine) and the portal-venous (gadolinium) phase for biphasic liver imaging. Mixed iodine and bismuth samples were prepared mimicking the arterial (iodine) and the enteric (bismuth) enhancement for small bowel imaging. For comparison to the reference condition of performing two single-energy CT (SECT) scans, contrast samples were prepared separately to mimic separate scans in the arterial/venous phase and arterial/enteric enhancement. Samples were placed in a 35 cm wide water tank and scanned using a third-generation dual-source DECT scanner with three tube potential pairs: 80/Sn150, 90/Sn150, and 100/Sn150 kV, all with default dose partitioning between two x-ray beams to acquire DECT data. The same scanner operated in a single-energy mode acquired SECT data (120 kV). Total radiation dose (CTDIvol) was matched for the single-scan DECT and the two-scan SECT protocols. The DECT protocol was followed by a generic image-based three-material decomposition method to determine the material-specific images, based on which concentrations of each basis material were quantified and noise levels were measured. To compare with the SECT images directly acquired with the SECT protocol, the concentration values in each contrast-specific image were converted to CT numbers at 120 kV (i.e., virtual SECT (vSECT) images). The noise level and noise power spectra differences between the SECT and vSECT images were compared to evaluate the dose efficiency of the single-scan DECT protocol. The impact of dose partitioning in the DECT protocol on quantitative dual-contrast imaging performance was also studied. RESULTS For each imaging task, contrast materials were accurately quantified against the nominal concentrations using the DECT data with strong correlation (R2 ≥ 0.98 for both imaging tasks). Compared to the SECT protocol, the DECT protocol was not dose efficient. With the optimal x-ray tube potential pair 80/Sn150 kV, the noise level in vSECT images increased by 401%/488% (arterial/portal-venous) for the biphasic liver imaging task and by 10%/41% (arterial/enteric) for the small bowel imaging task compared to that in SECT images. The corresponding radiation dose increase is 2410%/3357% for the biphasic liver imaging task and 21%/99% for the small bowel imaging task, respectively, to achieve the same noise as that in SECT images. This could be improved by adjusting the dose partitioning in DECT. CONCLUSIONS DECT can be used to simultaneously separate and quantify two contrast materials. However, compared to a two-scan SECT protocol, much higher radiation dose is needed in a single-scan DECT protocol to achieve the same image noise, especially for tasks involving the dual contrast of iodine and gadolinium.
Collapse
Affiliation(s)
- Liqiang Ren
- Department of Radiology, Mayo Clinic, Rochester, MN, 55905, USA
| | | | | | - Lifeng Yu
- Department of Radiology, Mayo Clinic, Rochester, MN, 55905, USA
| |
Collapse
|