Schlegel RN, Griffin S, Merchant A, Ma D, Owen A. Voxel-Based Dosimetry as a Means for Treatment Personalisation in Radioembolization: A Systematic Review. J Med Imaging Radiat Oncol 2025. [PMID: 39955785 DOI: 10.1111/1754-9485.13833] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2024] [Revised: 11/30/2024] [Accepted: 01/10/2025] [Indexed: 02/18/2025]
Abstract
INTRODUCTION Radionuclide therapy including 90Y radioembolization is an established form of brachytherapy for treatment of malignancy including hepatocellular carcinoma. Currently, there are several methods available to estimate patient absorbed dose, including voxel-based dosimetry, that can achieve a level of personalisation in the planning and outcome assessments of radioembolization. Despite the advantages of voxel-based dosimetry, it remains a relatively new concept in radioembolization. This study evaluates if voxel-based dosimetry was associated with improved treatment efficacy in radioembolization planning. METHODS A systematic review was conducted by searching relevant databases (Medline Ovid, PubMed, Embase Ovid, CINAHL Complete, Cochrane Library, CENTRAL, Australian New Zealand Clinical Trials Registry, ClinicalTrials.gov, WHO International Trials Registry, Google Scholar) for literature regarding voxel-based dosimetry in radioembolization. RESULTS A total of 41 papers were included for this systematic review. Review of these studies revealed that voxel-based dosimetry can benefit numerous aspects of radioembolization in radionuclide therapy including predicting tumour response, toxicity and patient survival. Numerous studies also indicated that voxel-based dosimetry in radioembolization is a more accurate approach in establishing a dose-effect relationship in targeted radionuclide therapy when compared to other methods. Despite these promising findings, these studies did not investigate or comment on the accuracy of voxel-based dosimetry. CONCLUSION The evidence from this review highlights that voxel-based dosimetry can improve treatment efficacy in radioembolization planning. However, further studies are required to validate the accuracy and feasibility of voxel-based dosimetry in clinical practice.
Collapse
Affiliation(s)
- R N Schlegel
- Barwon Medical Imaging, University Hospital Geelong, Geelong, Victoria, Australia
| | - S Griffin
- Barwon Health Library, University Hospital Geelong, Geelong, Victoria, Australia
| | - A Merchant
- Barwon Medical Imaging, University Hospital Geelong, Geelong, Victoria, Australia
| | - D Ma
- Barwon Medical Imaging, University Hospital Geelong, Geelong, Victoria, Australia
| | - A Owen
- Barwon Medical Imaging, University Hospital Geelong, Geelong, Victoria, Australia
| |
Collapse
|
2
|
Calatayud-Jordán J, Carrasco-Vela N, Chimeno-Hernández J, Carles-Fariña M, Olivas-Arroyo C, Bello-Arqués P, Pérez-Enguix D, Martí-Bonmatí L, Torres-Espallardo I. Y-90 PET/MR imaging optimization with a Bayesian penalized likelihood reconstruction algorithm. Phys Eng Sci Med 2024; 47:1397-1413. [PMID: 38884672 DOI: 10.1007/s13246-024-01452-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2024] [Accepted: 05/23/2024] [Indexed: 06/18/2024]
Abstract
Positron Emission Tomography (PET) imaging after90 Y liver radioembolization is used for both lesion identification and dosimetry. Bayesian penalized likelihood (BPL) reconstruction algorithms are an alternative to ordered subset expectation maximization (OSEM) with improved image quality and lesion detectability. The investigation of optimal parameters for90 Y image reconstruction of Q.Clear, a commercial BPL algorithm developed by General Electric (GE), in PET/MR is a field of interest and the subject of this study. The NEMA phantom was filled at an 8:1 sphere-to-background ratio. Acquisitions were performed on a PET/MR scanner for clinically relevant activities between 0.7 and 3.3 MBq/ml. Reconstructions with Q.Clear were performed varying the β penalty parameter between 20 and 6000, the acquisition time between 5 and 20 min and pixel size between 1.56 and 4.69 mm. OSEM reconstructions of 28 subsets with 2 and 4 iterations with and without Time-of-Flight (TOF) were compared to Q.Clear with β = 4000. Recovery coefficients (RC), their coefficient of variation (COV), background variability (BV), contrast-to-noise ratio (CNR) and residual activity in the cold insert were evaluated. Increasing β parameter lowered RC, COV and BV, while CNR was maximized at β = 4000; further increase resulted in oversmoothing. For quantification purposes, β = 1000-2000 could be more appropriate. Longer acquisition times resulted in larger CNR due to reduced image noise. Q.Clear reconstructions led to higher CNR than OSEM. A β of 4000 was obtained for optimal image quality, although lower values could be considered for quantification purposes. An optimal acquisition time of 15 min was proposed considering its clinical use.
Collapse
Affiliation(s)
- José Calatayud-Jordán
- Department of Nuclear Medicine, La Fe University and Polytechnical Hospital, Av. Fernando Abril Martorell 106, 46026, Valencia, Spain.
| | - Nuria Carrasco-Vela
- Radiophysics and Radiological Protection Service, Clinical University Hospital of Valencia, Av. Blasco Ibáñez 17, 46010, Valencia, Spain
| | - José Chimeno-Hernández
- Department of Nuclear Medicine, La Fe University and Polytechnical Hospital, Av. Fernando Abril Martorell 106, 46026, Valencia, Spain
| | - Montserrat Carles-Fariña
- Biomedical Imaging Research Group (GIBI230) at Health Research Institute Hospital La Fe (IIS La Fe), La Fe University and Polytechnical Hospital, Av. Fernando Abril Martorell 106, 46026, Valencia, Spain
| | - Consuelo Olivas-Arroyo
- Department of Nuclear Medicine, La Fe University and Polytechnical Hospital, Av. Fernando Abril Martorell 106, 46026, Valencia, Spain
| | - Pilar Bello-Arqués
- Department of Nuclear Medicine, La Fe University and Polytechnical Hospital, Av. Fernando Abril Martorell 106, 46026, Valencia, Spain
| | - Daniel Pérez-Enguix
- Department of Radiology, La Fe University and Polytechnical Hospital, Av. Fernando Abril Martorell 106, 46026, Valencia, Spain
| | - Luis Martí-Bonmatí
- Biomedical Imaging Research Group (GIBI230) at Health Research Institute Hospital La Fe (IIS La Fe), La Fe University and Polytechnical Hospital, Av. Fernando Abril Martorell 106, 46026, Valencia, Spain
- Department of Radiology, La Fe University and Polytechnical Hospital, Av. Fernando Abril Martorell 106, 46026, Valencia, Spain
| | - Irene Torres-Espallardo
- Department of Nuclear Medicine, La Fe University and Polytechnical Hospital, Av. Fernando Abril Martorell 106, 46026, Valencia, Spain
- Biomedical Imaging Research Group (GIBI230) at Health Research Institute Hospital La Fe (IIS La Fe), La Fe University and Polytechnical Hospital, Av. Fernando Abril Martorell 106, 46026, Valencia, Spain
| |
Collapse
|
3
|
Hadjivassiliou A, Hou X, Cardarelli-Leite L, Klyuzhin IS, Bénard F, Klass D, Ho SGF, Rahmim A, Liu D. Contralateral Hypertrophy Post Yttrium-90 Transarterial Radioembolization in Patients With Hepatocellular Carcinoma and Portal Vein Tumor Thrombus. Cureus 2024; 16:e59260. [PMID: 38813339 PMCID: PMC11135002 DOI: 10.7759/cureus.59260] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/28/2024] [Indexed: 05/31/2024] Open
Abstract
Objectives Contralateral hypertrophy of non-irradiated liver following Yttrium-90 (90Y) transarterial radioembolization (TARE) is increasingly recognized as an option to facilitate curative surgical resection in patients that would otherwise not be surgical candidates due to a small future liver remnant (FLR). This study aimed to investigate the correlation between patient features and liver hypertrophy and identify potential predictors for liver growth in patients with hepatocellular carcinoma (HCC) and portal vein tumor thrombus (PVTT) undergoing TARE. Methodology Twenty-three patients with HCC and PVTT were included. Contralateral liver hypertrophy was assessed at six months posttreatment based on CT or MRI imaging. Thirteen patient features were selected for statistical and prediction analysis. Univariate Spearman correlation and analysis of variance (ANOVA) tests were performed. Subsequently, four feature-selection methods based on multivariate analysis were used to improve model generalization performance. The selected features were applied to train linear regression models, with fivefold cross-validation to assess the performance of the predicted models. Results The ratio of disease-free target liver volume to spared liver volume and total liver volume showed the highest correlations with contralateral hypertrophy (P-values = 0.03 and 0.05, respectively). In three out of four feature-selection methods, the feature of disease-free target liver volume to total liver volume ratio was selected, having positive correlations with the outcome and suggesting that more hypertrophy may be expected when more volume of disease-free liver is irradiated. Conclusions Contralateral hypertrophy post-90Y TARE can be an option for facilitating surgical resection in patients with otherwise small FLR.
Collapse
Affiliation(s)
| | - Xinchi Hou
- Department of Functional Imaging, BC Cancer Research Institute, Vancouver, CAN
| | | | - Ivan S Klyuzhin
- Department of Integrative Oncology, BC Cancer Research Institute, Vancouver, CAN
| | - François Bénard
- Department of Molecular Oncology, BC Cancer Research Institute, Vancouver, CAN
- Department of Radiology, University of British Columbia, Vancouver, CAN
- Department of Functional Imaging, BC Cancer, Vancouver, CAN
| | - Darren Klass
- Department of Radiology, University of British Columbia, Vancouver, CAN
| | - Stephen G F Ho
- Department of Radiology, University of British Columbia, Vancouver, CAN
| | - Arman Rahmim
- Department of Radiology, University of British Columbia, Vancouver, CAN
- Department of Integrative Oncology, BC Cancer Research Institute, Vancouver, CAN
| | - David Liu
- Department of Radiology, University of British Columbia, Vancouver, CAN
| |
Collapse
|
4
|
Della Gala G, Santoro M, Rasoatsaratanany GA, Paolani G, Strolin S, Strigari L. A single centre intercomparison between commercial treatment planning systems for 90Y radioembolization using virtual and experimental phantoms. Phys Med 2023; 116:103172. [PMID: 38001000 DOI: 10.1016/j.ejmp.2023.103172] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/20/2023] [Revised: 10/30/2023] [Accepted: 11/14/2023] [Indexed: 11/26/2023] Open
Abstract
INTRODUCTION Dedicated Treatment Planning Systems (TPSs) were developed to personalize 90Y-transarterial radioembolization. This study evaluated the agreement among four commercial TPSs assessing volumes of interest (VOIs) volumes and dose metrics. METHODS A homogeneous (EH) and an anthropomorphic phantom with hot and cold inserts (EA) filled with 99mTc-pertechnetate were acquired with a SPECT/CT scanner. Their virtual versions (VH and VA, respectively) and a phantom with activity inside a single voxel (VK) were generated by an in-house MATLAB script. Images and delineated VOIs were imported into the TPSs to compute voxel-based absorbed dose distributions with various dose deposition approaches: local deposition method (LDM) and dose kernel convolution (DKC) with/without local density correction (LDC). VOI volumes and mean absorbed doses were assessed against their median value across TPSs. Dose-volume histograms (DVHs) and VK-derived dose profiles were evaluated. RESULTS Small (<2.1 %) and large (up to 42.4 %) relative volume differences were observed on large (>500 ml) and small VOIs, respectively. Mean absorbed doses relative differences were < 3 % except for small VOIs with steep dose gradients (up to 89.1 % in the VA Cold Sphere VOI). Within the same TPS, LDC negligibly affected the mean absorbed dose, while DKC and LDM showed differences up to 63 %. DHVs were mostly overlapped in experimental phantoms, with some differences in the virtual versions. Dose profiles agreed within 1 %. CONCLUSION TPSs showed an overall good agreement except for small VOI volumes and mean absorbed doses of VOIs with steep dose gradients. These discrepancies should be considered in the dosimetry uncertainty assessment, thus requiring an appropriate harmonization.
Collapse
Affiliation(s)
- Giuseppe Della Gala
- Department of Medical Physics, IRCCS Azienda Ospedaliero-Universitaria di Bologna, 40138, Bologna, Italy
| | - Miriam Santoro
- Department of Medical Physics, IRCCS Azienda Ospedaliero-Universitaria di Bologna, 40138, Bologna, Italy
| | - Garoson Albertine Rasoatsaratanany
- Department of Medical Physics, IRCCS Azienda Ospedaliero-Universitaria di Bologna, 40138, Bologna, Italy; International Center for Theoretical Physics (ICTP), Strada Costiera, 11, 34151, Trieste, Italy
| | - Giulia Paolani
- Department of Medical Physics, IRCCS Azienda Ospedaliero-Universitaria di Bologna, 40138, Bologna, Italy
| | - Silvia Strolin
- Department of Medical Physics, IRCCS Azienda Ospedaliero-Universitaria di Bologna, 40138, Bologna, Italy
| | - Lidia Strigari
- Department of Medical Physics, IRCCS Azienda Ospedaliero-Universitaria di Bologna, 40138, Bologna, Italy.
| |
Collapse
|
5
|
Santoro M, Della Gala G, Paolani G, Zagni F, Civollani S, Strolin S, Strigari L. A novel figure of merit to investigate 68Ga PET/CT image quality based on patient weight and lesion size using Q.Clear reconstruction algorithm: A phantom study. Phys Med 2023; 106:102523. [PMID: 36641902 DOI: 10.1016/j.ejmp.2022.102523] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/10/2022] [Revised: 12/23/2022] [Accepted: 12/27/2022] [Indexed: 01/15/2023] Open
Abstract
INTRODUCTION Q.Clear is a Bayesian penalised-likelihood algorithm that uses a β-value for positron emission tomography(PET)/computed tomography(CT) image reconstruction(IR). Our study proposes a novel figure of merit, named CRBV, to compare the Q.Clear performances using 68Ga PET/CT image with the ordered-subset-expectation-maximization(OSEM) algorithm and to identify the optimal β-values for these images using two phantoms mimicking normal and overweight patients. METHODS NEMA IQ phantom with or without a ring of water-filled plastic bags (NEMAstd and NEMAow, respectively) was acquired and reconstructed with OSEM and Q.Clear at various β-values and minutes/bed position(min/bp). Contrast recovery(CR), background variability(BV) and CRBV were calculated. Highest CRBV values were used to identify optimal β-value ranges. RESULTS Q.Clear with 250 ≤ β ≤ 800 improved CRBV compared to OSEM for all the investigated spheres and acquisition setups. Outside of this range, Q.Clear still outperformed OSEM with few exceptions depending on spheres diameters and phantoms(e.g.,β-value = 1600 for diameters ≤ 17 mm using the NEMAow phantom). Regarding the CRBV performance for IR optimization, for the 4 min/bp NEMAstd IR, β-values = 300 ÷ 350 allowed to simultaneously optimize all diameters(except for the 10 mm); for the NEMAow IR, β-values = 350 ÷ 500 were needed for diameters > 20 mm, while β-values = 200 ÷ 250 were selected for the remaining diameters. For the 2 min/bp, β-value = 500 was suitable for diameters > 17 mm in both NEMAstd and NEMAow IR, while for smaller diameters β-value = 200 and β-values = 250 ÷ 350 were obtained for NEMAstd and NEMAow, respectively. CONCLUSION Almost all tested β-values of Q.Clear improved the CRBV compared to OSEM. In both phantoms, simulating normal and over-weight patients, optimal β-values were found according to lesion sizes and investigated acquisition times.
Collapse
Affiliation(s)
- Miriam Santoro
- Department of Medical Physics, IRCCS Azienda Ospedaliero-Universitaria di Bologna, 40138 Bologna, Italy; Medical Physics Specialization School, Alma Mater Studiorum, University of Bologna, 40138 Bologna, Italy
| | - Giuseppe Della Gala
- Department of Medical Physics, IRCCS Azienda Ospedaliero-Universitaria di Bologna, 40138 Bologna, Italy
| | - Giulia Paolani
- Department of Medical Physics, IRCCS Azienda Ospedaliero-Universitaria di Bologna, 40138 Bologna, Italy; Medical Physics Specialization School, Alma Mater Studiorum, University of Bologna, 40138 Bologna, Italy
| | - Federico Zagni
- Department of Medical Physics, IRCCS Azienda Ospedaliero-Universitaria di Bologna, 40138 Bologna, Italy
| | - Simona Civollani
- Department of Medical Physics, IRCCS Azienda Ospedaliero-Universitaria di Bologna, 40138 Bologna, Italy
| | - Silvia Strolin
- Department of Medical Physics, IRCCS Azienda Ospedaliero-Universitaria di Bologna, 40138 Bologna, Italy
| | - Lidia Strigari
- Department of Medical Physics, IRCCS Azienda Ospedaliero-Universitaria di Bologna, 40138 Bologna, Italy.
| |
Collapse
|
6
|
Effects of Respiratory Motion on Y-90 PET Dosimetry for SIRT. Diagnostics (Basel) 2022; 12:diagnostics12010194. [PMID: 35054361 PMCID: PMC8775032 DOI: 10.3390/diagnostics12010194] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2021] [Revised: 01/07/2022] [Accepted: 01/10/2022] [Indexed: 12/04/2022] Open
Abstract
Respiratory motion degrades the quantification accuracy of PET imaging by blurring the radioactivity distribution. In the case of post-SIRT PET-CT verification imaging, respiratory motion can lead to inaccuracies in dosimetric measures. Using an anthropomorphic phantom filled with 90Y at a range of clinically relevant activities, together with a respiratory motion platform performing realistic motions (10–15 mm amplitude), we assessed the impact of respiratory motion on PET-derived post-SIRT dosimetry. Two PET scanners at two sites were included in the assessment. The phantom experiments showed that device-driven quiescent period respiratory motion correction improved the accuracy of the quantification with statistically significant increases in both the mean contrast recovery (+5%, p = 0.003) and the threshold activities corresponding to the dose to 80% of the volume of interest (+6%, p < 0.001). Although quiescent period gating also reduces the number of counts and hence increases the noise in the PET image, its use is encouraged where accurate quantification of the above metrics is desired.
Collapse
|
7
|
Della Gala G, Bardiès M, Tipping J, Strigari L. Overview of commercial treatment planning systems for targeted radionuclide therapy. Phys Med 2021; 92:52-61. [PMID: 34864422 DOI: 10.1016/j.ejmp.2021.11.001] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/15/2021] [Revised: 10/23/2021] [Accepted: 11/12/2021] [Indexed: 10/19/2022] Open
Abstract
INTRODUCTION Targeted Radionuclide Therapy (TRT) is a branch of cancer medicine dealing with the therapeutic use of radioisotopes associated with biological vectors accumulating in the tumors/targets, indicated as Molecular Radiotherapy (MRT), or directly injected into the arteries that supply blood to liver tumour vasculature, indicated as Selective RT (SRT). The aim of this work is to offer a panoramic view on the increasing number of commercially-available TRT treatment planning systems (TPSs). MATERIALS AND METHODS A questionnaire was sent to manufacturers' representatives. Academic software were not considered. Questions were grouped as follows: general information, clinical workflow, calibration procedure, image processing/reconstruction, image registration and segmentation tools, time-activity curve (TAC) fitting and absorbed dose calculation. RESULTS All software reported have CE-marking. TPSs were divided between SRT-dedicated software [4] and MRT [5] dosimetry software. In SRT, since no kinetic process is involved, absorbed dose calculation does not require TAC fitting, and image registration is not fully developed in all TPS. All software requires a radionuclide-specific calibration. In SRT, a relative image calibration can be obtained by scaling the counts to a known activity. Automated VOI contouring and rigid/deformable propagation between different acquisitions time-points is implemented in most TPSs, although DICOM export is rare. Different TAC fits are available depending on the number of time-points. Voxel S-value and Local deposition methods are the most frequent dosimetric approaches; dose-voxel kernel convolution and semi-Monte Carlo method are also available. CONCLUSIONS Available TPSs allows performing personalized dosimetry in clinical practice. Individual variations in methodology/algorithms must be considered in the standardisation/harmonization processes.
Collapse
Affiliation(s)
- Giuseppe Della Gala
- Department of Medical Physics, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy
| | - Manuel Bardiès
- Département de Médecine Nucléaire, Institut Régional du Cancer de Montpellier (ICM), Montpellier F-34298, France; IRCM, UMR 1194 INSERM, Université de Montpellier and Institut Régional du Cancer de Montpellier (ICM), Montpellier F-34298, France
| | - Jill Tipping
- The Christie NHS Foundation Trust, Manchester, UK
| | - Lidia Strigari
- Department of Medical Physics, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy.
| |
Collapse
|
8
|
Labour J, Boissard P, Baudier T, Khayi F, Kryza D, Durebex PV, Martino SPD, Mognetti T, Sarrut D, Badel JN. Yttrium-90 quantitative phantom study using digital photon counting PET. EJNMMI Phys 2021; 8:56. [PMID: 34318383 PMCID: PMC8316557 DOI: 10.1186/s40658-021-00402-6] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2021] [Accepted: 06/23/2021] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND PET imaging of 90Y-microsphere distribution following radioembolisation is challenging due to the count-starved statistics from the low branching ratio of e+/e- pair production during 90Y decay. PET systems using silicon photo-multipliers have shown better 90Y image quality compared to conventional photo-multiplier tubes. The main goal of the present study was to evaluate reconstruction parameters for different phantom configurations and varying listmode acquisition lengths to improve quantitative accuracy in 90Y dosimetry, using digital photon counting PET/CT. METHODS Quantitative PET and dosimetry accuracy were evaluated using two uniform cylindrical phantoms specific for PET calibration validation. A third body phantom with a 9:1 hot sphere-to-background ratio was scanned at different activity concentrations of 90Y. Reconstructions were performed using OSEM algorithm with varying parameters. Time-of-flight and point-spread function modellings were included in all reconstructions. Absorbed dose calculations were carried out using voxel S-values convolution and were compared to reference Monte Carlo simulations. Dose-volume histograms and root-mean-square deviations were used to evaluate reconstruction parameter sets. Using listmode data, phantom and patient datasets were rebinned into various lengths of time to assess the influence of count statistics on the calculation of absorbed dose. Comparisons between the local energy deposition method and the absorbed dose calculations were performed. RESULTS Using a 2-mm full width at half maximum post-reconstruction Gaussian filter, the dosimetric accuracy was found to be similar to that found with no filter applied but also reduced noise. Larger filter sizes should not be used. An acquisition length of more than 10 min/bed reduces image noise but has no significant impact in the quantification of phantom or patient data for the digital photon counting PET. 3 iterations with 10 subsets were found suitable for large spheres whereas 1 iteration with 30 subsets could improve dosimetry for smaller spheres. CONCLUSION The best choice of the combination of iterations and subsets depends on the size of the spheres. However, one should be careful on this choice, depending on the imaging conditions and setup. This study can be useful in this choice for future studies for more accurate 90Y post-dosimetry using a digital photon counting PET/CT.
Collapse
Affiliation(s)
- Joey Labour
- CREATIS; CNRS UMR 5220; INSERM U 1044; Université de Lyon; INSA-Lyon; Université Lyon 1, Lyon, France
- Centre de lutte contre le cancer Léon Bérard, Lyon, France
| | | | - Thomas Baudier
- CREATIS; CNRS UMR 5220; INSERM U 1044; Université de Lyon; INSA-Lyon; Université Lyon 1, Lyon, France
- Centre de lutte contre le cancer Léon Bérard, Lyon, France
| | - Fouzi Khayi
- Centre de lutte contre le cancer Léon Bérard, Lyon, France
| | - David Kryza
- Centre de lutte contre le cancer Léon Bérard, Lyon, France
- Hospices Civils de Lyon; Université de Lyon; Université Claude Bernard Lyon 1; LAGEPP UMR 5007 CNRS, Lyon, France
| | | | | | | | - David Sarrut
- CREATIS; CNRS UMR 5220; INSERM U 1044; Université de Lyon; INSA-Lyon; Université Lyon 1, Lyon, France
- Centre de lutte contre le cancer Léon Bérard, Lyon, France
| | - Jean-Noël Badel
- CREATIS; CNRS UMR 5220; INSERM U 1044; Université de Lyon; INSA-Lyon; Université Lyon 1, Lyon, France
- Centre de lutte contre le cancer Léon Bérard, Lyon, France
| |
Collapse
|