Jenny T, Duetschler A, Giger A, Pusterla O, Safai S, Weber DC, Lomax AJ, Zhang Y. Technical note: Towards more realistic 4DCT(MRI) numerical lung phantoms. Med Phys 2024; 51:579-590. [PMID: 37166067 DOI: 10.1002/mp.16451] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2022] [Revised: 04/17/2023] [Accepted: 04/18/2023] [Indexed: 05/12/2023] Open
Abstract
BACKGROUND Numerical 4D phantoms, together with associated ground truth motion, offer a flexible and comprehensive data set for realistic simulations in radiotherapy and radiology in target sites affected by respiratory motion. PURPOSE We present an openly available upgrade to previously reported methods for generating realistic 4DCT lung numerical phantoms, which now incorporate respiratory ribcage motion and improved lung density representation throughout the breathing cycle. METHODS Density information of reference CTs, toget her with motion from multiple breathing cycle 4DMRIs have been combined to generate synthetic 4DCTs (4DCT(MRI)s). Inter-subject correspondence between the CT and MRI anatomy was first established via deformable image registration (DIR) of binary masks of the lungs and ribcage. Ribcage and lung motions were extracted independently from the 4DMRIs using DIR and applied to the corresponding locations in the CT after post-processing to preserve sliding organ motion. In addition, based on the Jacobian determinant of the resulting deformation vector fields, lung densities were scaled on a voxel-wise basis to more accurately represent changes in local lung density. For validating this process, synthetic 4DCTs, referred to as 4DCT(CT)s, were compared to the originating 4DCTs using motion extracted from the latter, and the dosimetric impact of the new features of ribcage motion and density correction were analyzed using pencil beam scanned proton 4D dose calculations. RESULTS Lung density scaling led to a reduction of maximum mean lung Hounsfield units (HU) differences from 45 to 12 HU when comparing simulated 4DCT(CT)s to their originating 4DCTs. Comparing 4D dose distributions calculated on the enhanced 4DCT(CT)s to those on the original 4DCTs yielded 2%/2 mm gamma pass rates above 97% with an average improvement of 1.4% compared to previously reported phantoms. CONCLUSIONS A previously reported 4DCT(MRI) workflow has been successfully improved and the resulting numerical phantoms exhibit more accurate lung density representations and realistic ribcage motion.
Collapse
Affiliation(s)
- Timothy Jenny
- Center for Proton Therapy, Paul Scherrer Institute, Villigen, Switzerland
- Department of Physics, ETH Zürich, Zürich, Switzerland
| | - Alisha Duetschler
- Center for Proton Therapy, Paul Scherrer Institute, Villigen, Switzerland
- Department of Physics, ETH Zürich, Zürich, Switzerland
| | - Alina Giger
- Department of Biomedical Engineering, University of Basel, Basel, Switzerland
- Center for Medical Image Analysis & Navigation, University of Basel, Basel, Switzerland
| | - Orso Pusterla
- Department of Biomedical Engineering, University of Basel, Basel, Switzerland
- Department of Radiology, Division of Radiological Physics, University Hospital Basel, University of Basel, Basel, Switzerland
| | - Sairos Safai
- Center for Proton Therapy, Paul Scherrer Institute, Villigen, Switzerland
| | - Damien C Weber
- Center for Proton Therapy, Paul Scherrer Institute, Villigen, Switzerland
- Department of Radiation Oncology, University Hospital of Zürich, Zürich, Switzerland
- Department of Radiation Oncology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Antony J Lomax
- Center for Proton Therapy, Paul Scherrer Institute, Villigen, Switzerland
- Department of Physics, ETH Zürich, Zürich, Switzerland
| | - Ye Zhang
- Center for Proton Therapy, Paul Scherrer Institute, Villigen, Switzerland
| |
Collapse
|
2
|
Asano S, Oseki K, Takao S, Miyazaki K, Yokokawa K, Matsuura T, Taguchi H, Katoh N, Aoyama H, Umegaki K, Miyamoto N. Technical note: Performance evaluation of volumetric imaging based on motion modeling by principal component analysis. Med Phys 2023; 50:993-999. [PMID: 36427355 DOI: 10.1002/mp.16123] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2022] [Revised: 10/17/2022] [Accepted: 11/20/2022] [Indexed: 11/27/2022] Open
Abstract
PURPOSE To quantitatively evaluate the achievable performance of volumetric imaging based on lung motion modeling by principal component analysis (PCA). METHODS In volumetric imaging based on PCA, internal deformation was represented as a linear combination of the eigenvectors derived by PCA of the deformation vector fields evaluated from patient-specific four-dimensional-computed tomography (4DCT) datasets. The volumetric image was synthesized by warping the reference CT image with a deformation vector field which was evaluated using optimal principal component coefficients (PCs). Larger PCs were hypothesized to reproduce deformations larger than those included in the original 4DCT dataset. To evaluate the reproducibility of PCA-reconstructed volumetric images synthesized to be close to the ground truth as possible, mean absolute error (MAE), structure similarity index measure (SSIM) and discrepancy of diaphragm position were evaluated using 22 4DCT datasets of nine patients. RESULTS Mean MAE and SSIM values for the PCA-reconstructed volumetric images were approximately 80 HU and 0.88, respectively, regardless of the respiratory phase. In most test cases including the data of which motion range was exceeding that of the modeling data, the positional error of diaphragm was less than 5 mm. The results suggested that large deformations not included in the modeling 4DCT dataset could be reproduced. Furthermore, since the first PC correlated with the displacement of the diaphragm position, the first eigenvector became the dominant factor representing the respiration-associated deformations. However, other PCs did not necessarily change with the same trend as the first PC, and no correlation was observed between the coefficients. Hence, randomly allocating or sampling these PCs in expanded ranges may be applicable to reasonably generate an augmented dataset with various deformations. CONCLUSIONS Reasonable accuracy of image synthesis comparable to those in the previous research were shown by using clinical data. These results indicate the potential of PCA-based volumetric imaging for clinical applications.
Collapse
Affiliation(s)
- Suzuka Asano
- Graduate School of Engineering, Hokkaido University, Sapporo, Hokkaido, Japan
| | - Keishi Oseki
- Graduate School of Engineering, Hokkaido University, Sapporo, Hokkaido, Japan
| | - Seishin Takao
- Faculty of Engineering, Hokkaido University, Sapporo, Hokkaido, Japan.,Department of Medical Physics, Hokkaido University Hospital, Sapporo, Hokkaido, Japan
| | - Koichi Miyazaki
- Faculty of Engineering, Hokkaido University, Sapporo, Hokkaido, Japan.,Department of Medical Physics, Hokkaido University Hospital, Sapporo, Hokkaido, Japan
| | - Kohei Yokokawa
- Faculty of Engineering, Hokkaido University, Sapporo, Hokkaido, Japan.,Department of Medical Physics, Hokkaido University Hospital, Sapporo, Hokkaido, Japan
| | - Taeko Matsuura
- Faculty of Engineering, Hokkaido University, Sapporo, Hokkaido, Japan.,Department of Medical Physics, Hokkaido University Hospital, Sapporo, Hokkaido, Japan
| | - Hiroshi Taguchi
- Department of Radiation Oncology, Hokkaido University Hospital, Sapporo, Hokkaido, Japan
| | - Norio Katoh
- Faculty of Medicine, Hokkaido University, Sapporo, Hokkaido, Japan
| | - Hidefumi Aoyama
- Faculty of Medicine, Hokkaido University, Sapporo, Hokkaido, Japan
| | - Kikuo Umegaki
- Faculty of Engineering, Hokkaido University, Sapporo, Hokkaido, Japan.,Department of Medical Physics, Hokkaido University Hospital, Sapporo, Hokkaido, Japan
| | - Naoki Miyamoto
- Faculty of Engineering, Hokkaido University, Sapporo, Hokkaido, Japan.,Department of Medical Physics, Hokkaido University Hospital, Sapporo, Hokkaido, Japan
| |
Collapse
|
3
|
Duetschler A, Prendi J, Safai S, Weber DC, Lomax AJ, Zhang Y. Limitations of phase-sorting based pencil beam scanned 4D proton dose calculations under irregular motion. Phys Med Biol 2022; 68. [PMID: 36571234 DOI: 10.1088/1361-6560/aca9b6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2022] [Accepted: 12/07/2022] [Indexed: 12/12/2022]
Abstract
Objective.4D dose calculation (4DDC) for pencil beam scanned (PBS) proton therapy is typically based on phase-sorting of individual pencil beams onto phases of a single breathing cycle 4DCT. Understanding the dosimetric limitations and uncertainties of this approach is essential, especially for the realistic treatment scenario with irregular free breathing motion.Approach.For three liver and three lung cancer patient CTs, the deformable multi-cycle motion from 4DMRIs was used to generate six synthetic 4DCT(MRI)s, providing irregular motion (11/15 cycles for liver/lung; tumor amplitudes ∼4-18 mm). 4DDCs for two-field plans were performed, with the temporal resolution of the pencil beam delivery (4-200 ms) or with 8 phases per breathing cycle (500-1000 ms). For the phase-sorting approach, the tumor center motion was used to determine the phase assignment of each spot. The dose was calculated either using the full free breathing motion or individually repeating each single cycle. Additionally, the use of an irregular surrogate signal prior to 4DDC on a repeated cycle was simulated. The CTV volume with absolute dose differences >5% (Vdosediff>5%) and differences in CTVV95%andD5%-D95%compared to the free breathing scenario were evaluated.Main results.Compared to 4DDC considering the full free breathing motion with finer spot-wise temporal resolution, 4DDC based on a repeated single 4DCT resulted inVdosediff>5%of on average 34%, which resulted in an overestimation ofV95%up to 24%. However, surrogate based phase-sorting prior to 4DDC on a single cycle 4DCT, reduced the averageVdosediff>5%to 16% (overestimationV95%up to 19%). The 4DDC results were greatly influenced by the choice of reference cycle (Vdosediff>5%up to 55%) and differences due to temporal resolution were much smaller (Vdosediff>5%up to 10%).Significance.It is important to properly consider motion irregularity in 4D dosimetric evaluations of PBS proton treatments, as 4DDC based on a single 4DCT can lead to an underestimation of motion effects.
Collapse
Affiliation(s)
- A Duetschler
- Center for Proton Therapy, Paul Scherrer Institute, 5232 Villigen PSI, CH, Switzerland.,Department of Physics, ETH Zürich, 8092 Zürich, CH, Switzerland
| | - J Prendi
- Center for Proton Therapy, Paul Scherrer Institute, 5232 Villigen PSI, CH, Switzerland.,Department of Physics, University of Basel, 4056 Basel, CH, Switzerland
| | - S Safai
- Center for Proton Therapy, Paul Scherrer Institute, 5232 Villigen PSI, CH, Switzerland
| | - D C Weber
- Center for Proton Therapy, Paul Scherrer Institute, 5232 Villigen PSI, CH, Switzerland.,Department of Radiation Oncology, University Hospital of Zürich, 8091 Zürich, CH, Switzerland.,Department of Radiation Oncology, Inselspital, Bern University Hospital, University of Bern, 3010 Bern, CH, Switzerland
| | - A J Lomax
- Center for Proton Therapy, Paul Scherrer Institute, 5232 Villigen PSI, CH, Switzerland.,Department of Physics, ETH Zürich, 8092 Zürich, CH, Switzerland
| | - Ye Zhang
- Center for Proton Therapy, Paul Scherrer Institute, 5232 Villigen PSI, CH, Switzerland
| |
Collapse
|
4
|
Duetschler A, Bauman G, Bieri O, Cattin PC, Ehrbar S, Engin-Deniz G, Giger A, Josipovic M, Jud C, Krieger M, Nguyen D, Persson GF, Salomir R, Weber DC, Lomax AJ, Zhang Y. Synthetic 4DCT(MRI) lung phantom generation for 4D radiotherapy and image guidance investigations. Med Phys 2022; 49:2890-2903. [PMID: 35239984 PMCID: PMC9313613 DOI: 10.1002/mp.15591] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2021] [Revised: 12/26/2021] [Accepted: 02/24/2022] [Indexed: 11/14/2022] Open
Abstract
Purpose Respiratory motion is one of the major challenges in radiotherapy. In this work, a comprehensive and clinically plausible set of 4D numerical phantoms, together with their corresponding “ground truths,” have been developed and validated for 4D radiotherapy applications. Methods The phantoms are based on CTs providing density information and motion from multi‐breathing‐cycle 4D Magnetic Resonance imagings (MRIs). Deformable image registration (DIR) has been utilized to extract motion fields from 4DMRIs and to establish inter‐subject correspondence by registering binary lung masks between Computer Tomography (CT) and MRI. The established correspondence is then used to warp the CT according to the 4DMRI motion. The resulting synthetic 4DCTs are called 4DCT(MRI)s. Validation of the 4DCT(MRI) workflow was conducted by directly comparing conventional 4DCTs to derived synthetic 4D images using the motion of the 4DCTs themselves (referred to as 4DCT(CT)s). Digitally reconstructed radiographs (DRRs) as well as 4D pencil beam scanned (PBS) proton dose calculations were used for validation. Results Based on the CT image appearance of 13 lung cancer patients and deformable motion of five volunteer 4DMRIs, synthetic 4DCT(MRI)s with a total of 871 different breathing cycles have been generated. The 4DCT(MRI)s exhibit an average superior–inferior tumor motion amplitude of 7 ± 5 mm (min: 0.5 mm, max: 22.7 mm). The relative change of the DRR image intensities of the conventional 4DCTs and the corresponding synthetic 4DCT(CT)s inside the body is smaller than 5% for at least 81% of the pixels for all studied cases. Comparison of 4D dose distributions calculated on 4DCTs and the synthetic 4DCT(CT)s using the same motion achieved similar dose distributions with an average 2%/2 mm gamma pass rate of 90.8% (min: 77.8%, max: 97.2%). Conclusion We developed a series of numerical 4D lung phantoms based on real imaging and motion data, which give realistic representations of both anatomy and motion scenarios and the accessible “ground truth” deformation vector fields of each 4DCT(MRI). The open‐source code and motion data allow foreseen users to generate further 4D data by themselves. These numeric 4D phantoms can be used for the development of new 4D treatment strategies, 4D dose calculations, DIR algorithm validations, as well as simulations of motion mitigation and different online image guidance techniques for both proton and photon radiation therapy.
Collapse
Affiliation(s)
- Alisha Duetschler
- Center for Proton Therapy, Paul Scherrer Institute, Villigen PSI, 5232, Switzerland.,Department of Physics, ETH Zurich, Zurich, 8092, Switzerland
| | - Grzegorz Bauman
- Department of Biomedical Engineering, University of Basel, Allschwil, 4123, Switzerland.,Division of Radiological Physics, Department of Radiology, University Hospital Basel, Basel, 4031, Switzerland
| | - Oliver Bieri
- Department of Biomedical Engineering, University of Basel, Allschwil, 4123, Switzerland.,Division of Radiological Physics, Department of Radiology, University Hospital Basel, Basel, 4031, Switzerland
| | - Philippe C Cattin
- Department of Biomedical Engineering, University of Basel, Allschwil, 4123, Switzerland.,Center for medical Image Analysis & Navigation, University of Basel, Allschwil, 4123, Switzerland
| | - Stefanie Ehrbar
- Department of Radiation Oncology, University Hospital of Zurich, Zurich, 8091, Switzerland.,University of Zurich, Zurich, 8006, Switzerland
| | - Georg Engin-Deniz
- Center for Proton Therapy, Paul Scherrer Institute, Villigen PSI, 5232, Switzerland.,Department of Physics, ETH Zurich, Zurich, 8092, Switzerland
| | - Alina Giger
- Department of Biomedical Engineering, University of Basel, Allschwil, 4123, Switzerland.,Center for medical Image Analysis & Navigation, University of Basel, Allschwil, 4123, Switzerland
| | - Mirjana Josipovic
- Department of Oncology, Rigshospitalet Copenhagen University Hospital, Copenhagen, 2100, Denmark
| | - Christoph Jud
- Department of Biomedical Engineering, University of Basel, Allschwil, 4123, Switzerland.,Center for medical Image Analysis & Navigation, University of Basel, Allschwil, 4123, Switzerland
| | - Miriam Krieger
- Center for Proton Therapy, Paul Scherrer Institute, Villigen PSI, 5232, Switzerland.,Department of Physics, ETH Zurich, Zurich, 8092, Switzerland
| | - Damien Nguyen
- Department of Biomedical Engineering, University of Basel, Allschwil, 4123, Switzerland.,Division of Radiological Physics, Department of Radiology, University Hospital Basel, Basel, 4031, Switzerland
| | - Gitte F Persson
- Department of Oncology, Rigshospitalet Copenhagen University Hospital, Copenhagen, 2100, Denmark.,Department of Oncology, Herlev-Gentofte Hospital Copenhagen University Hospital, Herlev, 2730, Denmark.,Department of Clinical Medicine, Faculty of Medical Sciences, University of Copenhagen, Copenhagen, 2100, Denmark
| | - Rares Salomir
- Image Guided Interventions Laboratory (949), Faculty of Medicine, University of Geneva, Geneva, 1211, Switzerland.,Radiology Division, University Hospitals of Geneva, Geneva, 1205, Switzerland
| | - Damien C Weber
- Center for Proton Therapy, Paul Scherrer Institute, Villigen PSI, 5232, Switzerland.,Department of Radiation Oncology, University Hospital of Zurich, Zurich, 8091, Switzerland.,Department of Radiation Oncology, University of Bern, Bern, 3010, Switzerland
| | - Antony J Lomax
- Center for Proton Therapy, Paul Scherrer Institute, Villigen PSI, 5232, Switzerland.,Department of Physics, ETH Zurich, Zurich, 8092, Switzerland
| | - Ye Zhang
- Center for Proton Therapy, Paul Scherrer Institute, Villigen PSI, 5232, Switzerland
| |
Collapse
|
5
|
Dosimetry, Efficacy, Safety, and Cost-Effectiveness of Proton Therapy for Non-Small Cell Lung Cancer. Cancers (Basel) 2021; 13:cancers13184545. [PMID: 34572772 PMCID: PMC8465697 DOI: 10.3390/cancers13184545] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2021] [Revised: 09/04/2021] [Accepted: 09/07/2021] [Indexed: 12/24/2022] Open
Abstract
Non-small cell lung cancer (NSCLC) is the most common malignancy which requires radiotherapy (RT) as an important part of its multimodality treatment. With the advent of the novel irradiation technique, the clinical outcome of NSCLC patients who receive RT has been dramatically improved. The emergence of proton therapy, which allows for a sharper dose of build-up and drop-off compared to photon therapy, has potentially improved clinical outcomes of NSCLC. Dosimetry studies have indicated that proton therapy can significantly reduce the doses for normal organs, especially the lung, heart, and esophagus while maintaining similar robust target volume coverage in both early and advanced NSCLC compared with photon therapy. However, to date, most studies have been single-arm and concluded no significant changes in the efficacy for early-stage NSCLC by proton therapy over stereotactic body radiation therapy (SBRT). The results of proton therapy for advanced NSCLC in these studies were promising, with improved clinical outcomes and reduced toxicities compared with historical photon therapy data. However, these studies were also mainly single-arm and lacked a direct comparison between the two therapies. Currently, there is much emerging evidence focusing on dosimetry, efficacy, safety, and cost-effectiveness of proton therapy for NSCLC that has been published, however, a comprehensive review comparing these therapies is, to date, lacking. Thus, this review focuses on these aspects of proton therapy for NSCLC.
Collapse
|
6
|
Krieger M, Giger A, Jud C, Duetschler A, Salomir R, Bieri O, Bauman G, Nguyen D, Cattin PC, Weber DC, Lomax AJ, Zhang Y. Liver-ultrasound-guided lung tumour tracking for scanned proton therapy: a feasibility study. Phys Med Biol 2021; 66:035011. [PMID: 33238246 DOI: 10.1088/1361-6560/abcde6] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Pencil beam scanned (PBS) proton therapy of lung tumours is hampered by respiratory motion and the motion-induced density changes along the beam path. In this simulation study, we aim to investigate the effectiveness of proton beam tracking for lung tumours both under ideal conditions and in conjunction with a respiratory motion model guided by real-time ultrasound imaging of the liver. Multiple-breathing-cycle 4DMRIs of the thorax and abdominal 2D ultrasound images were acquired simultaneously for five volunteers. Deformation vector fields extracted from the 4DMRI, referred to as ground truth motion, were used to generate 4DCT(MRI) data sets of two lung cancer patients, resulting in 10 data sets with variable motion patterns. Given the 4DCT(MRI) and the corresponding ultrasound images as surrogate data, a patient-specific motion model was built. The model consists of an autoregressive model and Gaussian process regression for the temporal and spatial prediction, respectively. Two-field PBS plans were optimised on the reference CTs, and 4D dose calculations (4DDC) were used to simulate dose delivery for (a) unmitigated motion, (b) ideal 2D and 3D tracking (both beam adaption and 4DDC based on ground truth motion), and (c) realistic 2D and 3D tracking (beam adaption based on motion predictions, 4DDC on ground truth motion). Model-guided tracking retrieved clinically acceptable target dose homogeneity, as seen in a substantial reduction of the D5%-D95% compared to the non-mitigated simulation. Tracking in 2D and 3D resulted in a similar improvement of the dose homogeneity, as did ideal and realistic tracking simulations. In some cases, however, the tracked deliveries resulted in a shift towards higher or lower dose levels, leading to unacceptable target over- or under-coverage. The presented motion modelling framework was shown to be an accurate motion prediction tool for the use in proton beam tracking. Tracking alone, however, may not always effectively mitigate motion effects, making it necessary to combine it with other techniques such as rescanning.
Collapse
Affiliation(s)
- Miriam Krieger
- Center for Proton Therapy, Paul Scherrer Institute (PSI), Villigen PSI, Switzerland. Department of Physics, ETH Zurich, Zurich, Switzerland
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
7
|
Fattori G, Zhang Y, Meer D, Weber DC, Lomax AJ, Safai S. The potential of Gantry beamline large momentum acceptance for real time tumour tracking in pencil beam scanning proton therapy. Sci Rep 2020; 10:15325. [PMID: 32948790 PMCID: PMC7501279 DOI: 10.1038/s41598-020-71821-1] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2020] [Accepted: 08/18/2020] [Indexed: 02/01/2023] Open
Abstract
Tumour tracking is an advanced radiotherapy technique for precise treatment of tumours subject to organ motion. In this work, we addressed crucial aspects of dose delivery for its realisation in pencil beam scanning proton therapy, exploring the momentum acceptance and global achromaticity of a Gantry beamline to perform continuous energy regulation with a standard upstream degrader. This novel approach is validated on simulation data from three geometric phantoms of increasing complexity and one liver cancer patient using 4D dose calculations. Results from a standard high-to-low beamline ramping scheme were compared to alternative energy meandering schemes including combinations with rescanning. Target coverage and dose conformity were generally well recovered with tumour tracking even though for particularly small targets, large variations are reported for the different approaches. Meandering in energy while rescanning has a positive impact on target homogeneity and similarly, hot spots outside the targets are mitigated with a relatively fast convergence rate for most tracking scenarios, halving the volume of hot spots after as little as 3 rescans. This work investigates the yet unexplored potential of having a large momentum acceptance in medical beam line, and provides an alternative to take tumour tracking with particle therapy closer to clinical translation.
Collapse
Affiliation(s)
- Giovanni Fattori
- Center for Proton Therapy, WMSA/C14, Paul Scherrer Institute, 5232, Villigen, Switzerland.
| | - Ye Zhang
- Center for Proton Therapy, WMSA/C14, Paul Scherrer Institute, 5232, Villigen, Switzerland
| | - David Meer
- Center for Proton Therapy, WMSA/C14, Paul Scherrer Institute, 5232, Villigen, Switzerland
| | - Damien Charles Weber
- Center for Proton Therapy, WMSA/C14, Paul Scherrer Institute, 5232, Villigen, Switzerland.,Department of Radiation Oncology, University Hospital Zurich, 8091, Zurich, Switzerland.,Department of Radiation Oncology, University Hospital Bern, 3000, Bern, Switzerland
| | - Antony John Lomax
- Center for Proton Therapy, WMSA/C14, Paul Scherrer Institute, 5232, Villigen, Switzerland.,Department of Physics, ETH Zurich, 8092, Zurich, Switzerland
| | - Sairos Safai
- Center for Proton Therapy, WMSA/C14, Paul Scherrer Institute, 5232, Villigen, Switzerland
| |
Collapse
|