Kartini D, Sokol O, Talabnin C, Kobdaj C, Durante M, Krämer M, Fuss M. 3D high resolution clonogenic survival measurement of xrs-5 cells in low-dose region of carbon ion plans.
Int J Radiat Biol 2022;
99:488-498. [PMID:
35939100 DOI:
10.1080/09553002.2022.2110318]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/15/2022]
Abstract
PURPOSE
In this study, we performed biological verification measurements of cell survival of a 12C ion irradiation plan employing a high-resolution 3D culture setup. This allowed, in particular, to access the cell inactivation in the low-dose regions close to the target area.
MATERIALS AND METHODS
We established the protocol for a 3D culture setup where xrs-5 cells were grown inside a layered matrigel structure in 384-well plates. Their radiosensitivity to conventional and 12C ion radiation was evaluated by irradiating them either with 250 kV X-rays at GSI or with monoenergetic 12C beams of 110 MeV/u at MIT, and compared with those of monolayers. A treatment plan for a rectangular target was prepared using the GSI research treatment planning system TRiP98. xrs-5 cells were seeded in the matrigel-based setup and irradiated in dose fall-off regions using active scanning 12C ion beams. In addition, film dosimetry utilizing radiochromic EBT3 film has been performed to assess the field homogeneity downstream of 384-well V-bottom plates with or without additional agarose coating of the well plate bottom.
RESULTS
Dose response curves following X-ray and 12C ion irradiation had linear shape and showed a significant decrease in survival fraction at even moderate doses. Survival measurements in the low-dose regions of the plan for the extended target showed good agreement to the predicted survival fraction. The irradiated film profiles yielded a flat dose distribution without apparent artifacts or inhomogeneities for well plates both with and without agarose coating, confirming the suitability of the experimental setup.
CONCLUSIONS
We conclude that the V-bottom 384-well plates in combination with the radiation-sensitive xrs-5 cell line constitute a suitable radiobiological verification tool which can be used especially for low doses. Furthermore, the measured survival of xrs-5 cells show a good agreement with the expected survival in the low-dose out-of-field regions, both laterally and downstream of the target.
Collapse