Li X, Bellotti R, Bachtiary B, Hrbacek J, Weber DC, Lomax AJ, Buhmann JM, Zhang Y. A unified generation-registration framework for improved MR-based CT synthesis in proton therapy. Med Phys 2024. [PMID: 39137294 DOI: 10.1002/mp.17338] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2024] [Revised: 06/11/2024] [Accepted: 07/06/2024] [Indexed: 08/15/2024] Open
Abstract
BACKGROUND The use of magnetic resonance (MR) imaging for proton therapy treatment planning is gaining attention as a highly effective method for guidance. At the core of this approach is the generation of computed tomography (CT) images from MR scans. However, the critical issue in this process is accurately aligning the MR and CT images, a task that becomes particularly challenging in frequently moving body areas, such as the head-and-neck. Misalignments in these images can result in blurred synthetic CT (sCT) images, adversely affecting the precision and effectiveness of the treatment planning. PURPOSE This study introduces a novel network that cohesively unifies image generation and registration processes to enhance the quality and anatomical fidelity of sCTs derived from better-aligned MR images. METHODS The approach synergizes a generation network (G) with a deformable registration network (R), optimizing them jointly in MR-to-CT synthesis. This goal is achieved by alternately minimizing the discrepancies between the generated/registered CT images and their corresponding reference CT counterparts. The generation network employs a UNet architecture, while the registration network leverages an implicit neural representation (INR) of the displacement vector fields (DVFs). We validated this method on a dataset comprising 60 head-and-neck patients, reserving 12 cases for holdout testing. RESULTS Compared to the baseline Pix2Pix method with MAE 124.95 ± $\pm$ 30.74 HU, the proposed technique demonstrated 80.98 ± $\pm$ 7.55 HU. The unified translation-registration network produced sharper and more anatomically congruent outputs, showing superior efficacy in converting MR images to sCTs. Additionally, from a dosimetric perspective, the plan recalculated on the resulting sCTs resulted in a remarkably reduced discrepancy to the reference proton plans. CONCLUSIONS This study conclusively demonstrates that a holistic MR-based CT synthesis approach, integrating both image-to-image translation and deformable registration, significantly improves the precision and quality of sCT generation, particularly for the challenging body area with varied anatomic changes between corresponding MR and CT.
Collapse
Affiliation(s)
- Xia Li
- Center for Proton Therapy, Paul Scherrer Institut, Villigen PSI, Switzerland
- Department of Computer Science, ETH Zürich, Zürich, Switzerland
| | - Renato Bellotti
- Center for Proton Therapy, Paul Scherrer Institut, Villigen PSI, Switzerland
- Department of Physics, ETH Zürich, Zürich, Switzerland
| | - Barbara Bachtiary
- Center for Proton Therapy, Paul Scherrer Institut, Villigen PSI, Switzerland
| | - Jan Hrbacek
- Center for Proton Therapy, Paul Scherrer Institut, Villigen PSI, Switzerland
| | - Damien C Weber
- Center for Proton Therapy, Paul Scherrer Institut, Villigen PSI, Switzerland
- Department of Radiation Oncology, University Hospital of Zürich, Zürich, Switzerland
- Department of Radiation Oncology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Antony J Lomax
- Center for Proton Therapy, Paul Scherrer Institut, Villigen PSI, Switzerland
- Department of Physics, ETH Zürich, Zürich, Switzerland
| | | | - Ye Zhang
- Center for Proton Therapy, Paul Scherrer Institut, Villigen PSI, Switzerland
| |
Collapse
|
2
|
Sherwani MK, Gopalakrishnan S. A systematic literature review: deep learning techniques for synthetic medical image generation and their applications in radiotherapy. FRONTIERS IN RADIOLOGY 2024; 4:1385742. [PMID: 38601888 PMCID: PMC11004271 DOI: 10.3389/fradi.2024.1385742] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/13/2024] [Accepted: 03/11/2024] [Indexed: 04/12/2024]
Abstract
The aim of this systematic review is to determine whether Deep Learning (DL) algorithms can provide a clinically feasible alternative to classic algorithms for synthetic Computer Tomography (sCT). The following categories are presented in this study: ∙ MR-based treatment planning and synthetic CT generation techniques. ∙ Generation of synthetic CT images based on Cone Beam CT images. ∙ Low-dose CT to High-dose CT generation. ∙ Attenuation correction for PET images. To perform appropriate database searches, we reviewed journal articles published between January 2018 and June 2023. Current methodology, study strategies, and results with relevant clinical applications were analyzed as we outlined the state-of-the-art of deep learning based approaches to inter-modality and intra-modality image synthesis. This was accomplished by contrasting the provided methodologies with traditional research approaches. The key contributions of each category were highlighted, specific challenges were identified, and accomplishments were summarized. As a final step, the statistics of all the cited works from various aspects were analyzed, which revealed that DL-based sCTs have achieved considerable popularity, while also showing the potential of this technology. In order to assess the clinical readiness of the presented methods, we examined the current status of DL-based sCT generation.
Collapse
Affiliation(s)
- Moiz Khan Sherwani
- Section for Evolutionary Hologenomics, Globe Institute, University of Copenhagen, Copenhagen, Denmark
| | | |
Collapse
|
3
|
Zhao X, Bai JW, Guo Q, Ren K, Zhang GJ. Clinical applications of deep learning in breast MRI. Biochim Biophys Acta Rev Cancer 2023; 1878:188864. [PMID: 36822377 DOI: 10.1016/j.bbcan.2023.188864] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2022] [Revised: 01/05/2023] [Accepted: 01/17/2023] [Indexed: 02/25/2023]
Abstract
Deep learning (DL) is one of the most powerful data-driven machine-learning techniques in artificial intelligence (AI). It can automatically learn from raw data without manual feature selection. DL models have led to remarkable advances in data extraction and analysis for medical imaging. Magnetic resonance imaging (MRI) has proven useful in delineating the characteristics and extent of breast lesions and tumors. This review summarizes the current state-of-the-art applications of DL models in breast MRI. Many recent DL models were examined in this field, along with several advanced learning approaches and methods for data normalization and breast and lesion segmentation. For clinical applications, DL-based breast MRI models were proven useful in five aspects: diagnosis of breast cancer, classification of molecular types, classification of histopathological types, prediction of neoadjuvant chemotherapy response, and prediction of lymph node metastasis. For subsequent studies, further improvement in data acquisition and preprocessing is necessary, additional DL techniques in breast MRI should be investigated, and wider clinical applications need to be explored.
Collapse
Affiliation(s)
- Xue Zhao
- Fujian Key Laboratory of Precision Diagnosis and Treatment in Breast Cancer, Xiang'an Hospital of Xiamen University, School of Medicine, Xiamen University, Xiamen, China; National Institute for Data Science in Health and Medicine, Xiamen University, Xiamen, China; Department of Breast-Thyroid-Surgery and Cancer Center, Xiang'an Hospital of Xiamen University, School of Medicine, Xiamen University, Xiamen, China; Xiamen Research Center of Clinical Medicine in Breast & Thyroid Cancers, Xiang'an Hospital of Xiamen University, School of Medicine, Xiamen University, Xiamen, China; Xiamen Key Laboratory of Endocrine-Related Cancer Precision Medicine, Xiang'an Hospital of Xiamen University, School of Medicine, Xiamen University, Xiamen, China
| | - Jing-Wen Bai
- Fujian Key Laboratory of Precision Diagnosis and Treatment in Breast Cancer, Xiang'an Hospital of Xiamen University, School of Medicine, Xiamen University, Xiamen, China; Xiamen Research Center of Clinical Medicine in Breast & Thyroid Cancers, Xiang'an Hospital of Xiamen University, School of Medicine, Xiamen University, Xiamen, China; Xiamen Key Laboratory of Endocrine-Related Cancer Precision Medicine, Xiang'an Hospital of Xiamen University, School of Medicine, Xiamen University, Xiamen, China; Department of Oncology, Xiang'an Hospital of Xiamen University, School of Medicine, Xiamen University, Xiamen, China; Cancer Research Center, School of Medicine, Xiamen University, Xiamen, China
| | - Qiu Guo
- Department of Radiology, Xiang'an Hospital of Xiamen University, School of Medicine, Xiamen University, Xiamen, China
| | - Ke Ren
- Department of Radiology, Xiang'an Hospital of Xiamen University, School of Medicine, Xiamen University, Xiamen, China.
| | - Guo-Jun Zhang
- Fujian Key Laboratory of Precision Diagnosis and Treatment in Breast Cancer, Xiang'an Hospital of Xiamen University, School of Medicine, Xiamen University, Xiamen, China; Department of Breast-Thyroid-Surgery and Cancer Center, Xiang'an Hospital of Xiamen University, School of Medicine, Xiamen University, Xiamen, China; Xiamen Research Center of Clinical Medicine in Breast & Thyroid Cancers, Xiang'an Hospital of Xiamen University, School of Medicine, Xiamen University, Xiamen, China; Xiamen Key Laboratory of Endocrine-Related Cancer Precision Medicine, Xiang'an Hospital of Xiamen University, School of Medicine, Xiamen University, Xiamen, China; Cancer Research Center, School of Medicine, Xiamen University, Xiamen, China.
| |
Collapse
|
4
|
Nousiainen K, Santurio GV, Lundahl N, Cronholm R, Siversson C, Edmund JM. Evaluation of MRI-only based online adaptive radiotherapy of abdominal region on MR-linac. J Appl Clin Med Phys 2023; 24:e13838. [PMID: 36347050 PMCID: PMC10018672 DOI: 10.1002/acm2.13838] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2021] [Revised: 09/30/2022] [Accepted: 10/18/2022] [Indexed: 11/09/2022] Open
Abstract
PURPOSE A hybrid magnetic resonance linear accelerator (MRL) can perform magnetic resonance imaging (MRI) with high soft-tissue contrast to be used for online adaptive radiotherapy (oART). To obtain electron densities needed for the oART dose calculation, a computed tomography (CT) is often deformably registered to MRI. Our aim was to evaluate an MRI-only based synthetic CT (sCT) generation as an alternative to the deformed CT (dCT)-based oART in the abdominal region. METHODS The study data consisted of 57 patients who were treated on a 0.35 T MRL system mainly for abdominal tumors. Simulation MRI-CT pairs of 43 patients were used for training and validation of a prototype convolutional neural network sCT-generation algorithm, based on HighRes3DNet, for the abdominal region. For remaining test patients, sCT images were produced from simulation MRIs and daily MRIs. The dCT-based plans were re-calculated on sCT with identical calculation parameters. The sCT and dCT were compared in terms of geometric agreement and calculated dose. RESULTS The mean and one standard deviation of the geometric agreement metrics over dCT-sCT-pairs were: mean error of 8 ± 10 HU, mean absolute error of 49 ± 10 HU, and Dice similarity coefficient of 55 ± 12%, 60 ± 5%, and 82 ± 15% for bone, fat, and lung tissues, respectively. The dose differences between the sCT and dCT-based dose for planning target volumes were 0.5 ± 0.9%, 0.6 ± 0.8%, and 0.5 ± 0.8% at D2% , D50% , and D98% in physical dose and 0.8 ± 1.4%, 0.8 ± 1.2%, and 0.6 ± 1.1% in biologically effective dose (BED). For organs-at-risk, the dose differences of all evaluated dose-volume histogram points were within [-4.5%, 7.8%] and [-1.1 Gy, 3.5 Gy] in both physical dose and BED. CONCLUSIONS The geometric agreement metrics were within typically reported values and most average relative dose differences were within 1%. Thus, an MRI-only sCT-based approach is a promising alternative to the current clinical practice of the abdominal oART on MRL.
Collapse
Affiliation(s)
- Katri Nousiainen
- Department of Physics, University of Helsinki, Helsinki, Finland.,HUS Cancer Center, Helsinki University Hospital and University of Helsinki, Helsinki, Finland.,HUS Medical Imaging Center, Helsinki University Hospital and University of Helsinki, Helsinki, Finland
| | - Grichar Valdes Santurio
- Department of Oncology, Radiotherapy Research Unit, Herlev and Gentofte Hospital, Copenhagen University, Herlev, Denmark
| | | | | | | | - Jens M Edmund
- Department of Oncology, Radiotherapy Research Unit, Herlev and Gentofte Hospital, Copenhagen University, Herlev, Denmark.,Nils Bohr Institute, Copenhagen University, Copenhagen, Denmark
| |
Collapse
|
5
|
De-Colle C, Kirby A, Russell N, Shaitelman S, Currey A, Donovan E, Hahn E, Han K, Anandadas C, Mahmood F, Lorenzen E, van den Bongard D, Groot Koerkamp M, Houweling A, Nachbar M, Thorwarth D, Zips D. Adaptive radiotherapy for breast cancer. Clin Transl Radiat Oncol 2023; 39:100564. [PMID: 36632056 PMCID: PMC9826896 DOI: 10.1016/j.ctro.2022.100564] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2022] [Revised: 12/07/2022] [Accepted: 12/14/2022] [Indexed: 12/24/2022] Open
Abstract
Research in the field of local and locoregional breast cancer radiotherapy aims to maintain excellent oncological outcomes while reducing treatment-related toxicity. Adaptive radiotherapy (ART) considers variations in target and organs at risk (OARs) anatomy occurring during the treatment course and integrates these in re-optimized treatment plans. Exploiting ART routinely in clinic may result in smaller target volumes and better OAR sparing, which may lead to reduction of acute as well as late toxicities. In this review MR-guided and CT-guided ART for breast cancer patients according to different clinical scenarios (neoadjuvant and adjuvant partial breast irradiation, whole breast, chest wall and regional nodal irradiation) are reviewed and their advantages as well as challenging aspects discussed.
Collapse
Affiliation(s)
- C. De-Colle
- Department of Radiation Oncology, University Hospital and Medical Faculty, Eberhard Karls University Tübingen, Tübingen, Germany
| | - A. Kirby
- Department of Radiotherapy, Royal Marsden NHS Foundation Trust and Institute of Cancer Research, Sutton, United Kingdom
| | - N. Russell
- Department of Radiotherapy, The Netherlands Cancer Institute–Antoni van Leeuwenhoek Hospital, Amsterdam, Netherlands
| | - S.F. Shaitelman
- Department of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, TX, United States
| | - A. Currey
- Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, WI, United States
| | - E. Donovan
- Department of Radiation Oncology, Odette Cancer Centre - Sunnybrook Health Sciences Centre, Toronto, Canada
| | - E. Hahn
- Department of Radiation Oncology, Princess Margaret Cancer Centre, Toronto, Canada
| | - K. Han
- Department of Radiation Oncology, Princess Margaret Cancer Centre, Toronto, Canada
| | - C.N. Anandadas
- Department of Clinical Oncology, The Christie NHS Foundation Trust, Manchester, United Kingdom
| | - F. Mahmood
- Department of Oncology, Odense University Hospital, Odense, Denmark
| | - E.L. Lorenzen
- Department of Oncology, Odense University Hospital, Odense, Denmark
| | | | - M.L. Groot Koerkamp
- Department of Radiation Oncology, University Medical Center Utrecht, Utrecht, Netherlands
| | - A.C. Houweling
- Department of Radiation Oncology, University Medical Center Utrecht, Utrecht, Netherlands
| | - M. Nachbar
- Section for Biomedical Physics, Department of Radiation Oncology. University Hospital and Medical Faculty, Eberhard Karls University Tübingen, Tübingen, Germany
| | - D. Thorwarth
- Section for Biomedical Physics, Department of Radiation Oncology. University Hospital and Medical Faculty, Eberhard Karls University Tübingen, Tübingen, Germany
- German Cancer Consortium (DKTK), partner site Tübingen; and German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - D. Zips
- Department of Radiation Oncology, University Hospital and Medical Faculty, Eberhard Karls University Tübingen, Tübingen, Germany
- German Cancer Consortium (DKTK), partner site Tübingen; and German Cancer Research Center (DKFZ), Heidelberg, Germany
| |
Collapse
|
6
|
Parrella G, Vai A, Nakas A, Garau N, Meschini G, Camagni F, Molinelli S, Barcellini A, Pella A, Ciocca M, Vitolo V, Orlandi E, Paganelli C, Baroni G. Synthetic CT in Carbon Ion Radiotherapy of the Abdominal Site. Bioengineering (Basel) 2023; 10:bioengineering10020250. [PMID: 36829745 PMCID: PMC9951997 DOI: 10.3390/bioengineering10020250] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2023] [Revised: 02/06/2023] [Accepted: 02/09/2023] [Indexed: 02/17/2023] Open
Abstract
The generation of synthetic CT for carbon ion radiotherapy (CIRT) applications is challenging, since high accuracy is required in treatment planning and delivery, especially in an anatomical site as complex as the abdomen. Thirty-nine abdominal MRI-CT volume pairs were collected and a three-channel cGAN (accounting for air, bones, soft tissues) was used to generate sCTs. The network was tested on five held-out MRI volumes for two scenarios: (i) a CT-based segmentation of the MRI channels, to assess the quality of sCTs and (ii) an MRI manual segmentation, to simulate an MRI-only treatment scenario. The sCTs were evaluated by means of similarity metrics (e.g., mean absolute error, MAE) and geometrical criteria (e.g., dice coefficient). Recalculated CIRT plans were evaluated through dose volume histogram, gamma analysis and range shift analysis. The CT-based test set presented optimal MAE on bones (86.03 ± 10.76 HU), soft tissues (55.39 ± 3.41 HU) and air (54.42 ± 11.48 HU). Higher values were obtained from the MRI-only test set (MAEBONE = 154.87 ± 22.90 HU). The global gamma pass rate reached 94.88 ± 4.9% with 3%/3 mm, while the range shift reached a median (IQR) of 0.98 (3.64) mm. The three-channel cGAN can generate acceptable abdominal sCTs and allow for CIRT dose recalculations comparable to the clinical plans.
Collapse
Affiliation(s)
- Giovanni Parrella
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milan, Italy
- Correspondence: ; Tel.: +39-02-2399-18-9022
| | - Alessandro Vai
- Medical Physics Unit, National Center of Oncological Hadrontherapy (CNAO), Strada Campeggi, 53, 27100 Pavia, Italy
| | - Anestis Nakas
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milan, Italy
| | - Noemi Garau
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milan, Italy
| | - Giorgia Meschini
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milan, Italy
| | - Francesca Camagni
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milan, Italy
| | - Silvia Molinelli
- Medical Physics Unit, National Center of Oncological Hadrontherapy (CNAO), Strada Campeggi, 53, 27100 Pavia, Italy
| | - Amelia Barcellini
- Radiotherapy Unit, National Center of Oncological Hadrontherapy (CNAO), Strada Campeggi, 53, 27100 Pavia, Italy
- Department of Internal Medicine and Medical Therapy, University of Pavia, 27100 Pavia, Italy
| | - Andrea Pella
- Bioengineering Unit, National Center of Oncological Hadrontherapy (CNAO), Strada Campeggi, 53, 27100 Pavia, Italy
| | - Mario Ciocca
- Medical Physics Unit, National Center of Oncological Hadrontherapy (CNAO), Strada Campeggi, 53, 27100 Pavia, Italy
| | - Viviana Vitolo
- Radiotherapy Unit, National Center of Oncological Hadrontherapy (CNAO), Strada Campeggi, 53, 27100 Pavia, Italy
| | - Ester Orlandi
- Clinical Unit, National Center of Oncological Hadrontherapy (CNAO), Strada Campeggi, 53, 27100 Pavia, Italy
| | - Chiara Paganelli
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milan, Italy
| | - Guido Baroni
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milan, Italy
| |
Collapse
|
7
|
Abu-Qasmieh IF, Masad IS, Al-Quran HH, Alawneh KZ. Generation of Synthetic-Pseudo MR Images from Real CT Images. Tomography 2022; 8:1244-1259. [PMID: 35645389 PMCID: PMC9149978 DOI: 10.3390/tomography8030103] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2022] [Revised: 04/24/2022] [Accepted: 04/25/2022] [Indexed: 11/18/2022] Open
Abstract
This study aimed to generate synthetic MR images from real CT images. CT# mean and standard deviation of a moving window across every pixel in the reconstructed CT images were mapped to their corresponding tissue-mimicking types. Identification of the tissue enabled remapping it to its corresponding intrinsic parameters: T1, T2, and proton density (ρ). Lastly, synthetic weighted MR images of a selected slice were generated by simulating a spin-echo sequence using the intrinsic parameters and proper contrast parameters (TE and TR). Experiments were performed on a 3D multimodality abdominal phantom and on human knees at different TE and TR parameters to confirm the clinical effectiveness of the approach. Results demonstrated the validity of the approach of generating synthetic MR images at different weightings using only CT images and the three predefined mapping functions. The slope of the fitting line and percentage root-mean-square difference (PRD) between real and synthetic image vector representations were (0.73, 10%), (0.9, 18%), and (0.2, 8.7%) for T1-, T2-, and ρ-weighted images of the phantom, respectively. The slope and PRD for human knee images, on average, were 0.89% and 18.8%, respectively. The generated MR images provide valuable guidance for physicians with regard to deciding whether acquiring real MR images is crucial.
Collapse
Affiliation(s)
- Isam F. Abu-Qasmieh
- Department of Biomedical Systems and Informatics Engineering, Yarmouk University, Irbid 21163, Jordan; (I.F.A.-Q.); (H.H.A.-Q.)
| | - Ihssan S. Masad
- Department of Biomedical Systems and Informatics Engineering, Yarmouk University, Irbid 21163, Jordan; (I.F.A.-Q.); (H.H.A.-Q.)
- Correspondence:
| | - Hiam H. Al-Quran
- Department of Biomedical Systems and Informatics Engineering, Yarmouk University, Irbid 21163, Jordan; (I.F.A.-Q.); (H.H.A.-Q.)
- Department of Biomedical Engineering, Jordan University of Science and Technology, Irbid 22110, Jordan
| | - Khaled Z. Alawneh
- Faculty of Medicine, Jordan University of Science and Technology, King Abdullah University Hospital, Irbid 22110, Jordan;
| |
Collapse
|
8
|
Habatsch M, Schneider M, Requardt M, Doussin S. Movement assessment of breast and organ-at-risks using free-breathing, self-gating 4D magnetic resonance imaging workflow for breast cancer radiation therapy. Phys Imaging Radiat Oncol 2022; 22:111-114. [PMID: 35619641 PMCID: PMC9127201 DOI: 10.1016/j.phro.2022.05.007] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2020] [Revised: 05/10/2022] [Accepted: 05/11/2022] [Indexed: 12/01/2022] Open
Abstract
Motion management is essential in treatment planning of radiotherapy for breast cancer. This study assessed the movement of organs-at-risk and the breast using 4D magnetic resonance imaging (MRI). A self-gating respiration-resolved radial 3D gradient echo sequence was used. Five healthy volunteers were imaged at 1.5 T during free-breathing in supine position making use of a breast board. Median distances between heart and chest wall in axial views were 2.4 cm (range: 1.5 cm) and 3.0 cm (range: 1.7 cm) for end-of-exhale and end-of-inhale. 4D-MRI allowed organ delineation and might be a promising addition to novel RT planning for breast cancer patients.
Collapse
|
9
|
Groot Koerkamp ML, van der Leij F, van 't Westeinde T, Bol GH, Scholten V, Bouwmans R, Mandija S, Philippens MEP, van den Bongard HJGD, Houweling AC. Prone vs. supine accelerated partial breast irradiation on an MR-Linac: A planning study. Radiother Oncol 2021; 165:193-199. [PMID: 34774649 DOI: 10.1016/j.radonc.2021.11.001] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2021] [Revised: 11/01/2021] [Accepted: 11/03/2021] [Indexed: 02/07/2023]
Abstract
BACKGROUND AND PURPOSE Accelerated partial breast irradiation (APBI) may benefit from the MR-Linac for target definition, patient setup, and motion monitoring. In this planning study, we investigated whether prone or supine position is dosimetrically beneficial for APBI on an MR-Linac and we evaluated patient comfort. MATERIALS AND METHODS Twenty-patients (9 postoperative, 11 preoperative) with a DCIS or breast tumor <3 cm underwent 1.5 T MRI in prone and supine position. The tumor or tumor bed was delineated as GTV and a 2 cm CTV-margin and 0.5 cm PTV-margin were added. 1.5 T MR-Linac treatment plans (5 × 5.2 Gy) with 11 beams were created for both positions in each patient. We evaluated the number of plans that achieved the planning constraints and performed a dosimetric comparison between prone and supine position using the Wilcoxon signed-rank test (p-value <0.01 for significance). Patient experience during scanning was evaluated with a questionnaire. RESULTS All 40 plans met the target coverage and OAR constraints, regardless of position. Heart Dmean was not significantly different (1.07 vs. 0.79 Gy, p-value: 0.027). V5Gy to the ipsilateral lung (4.4% vs. 9.8% median, p-value 0.009) and estimated delivery time (362 vs. 392 s, p-value: 0.003) were significantly lower for prone position. PTV coverage and dose to other OAR were comparable between positions. The majority of patients (13/20) preferred supine position. CONCLUSION APBI on the MR-Linac is dosimetrically feasible in prone and supine position. Mean heart dose was similar in both positions. Ipsilateral lung V5Gy was lower in prone position.
Collapse
Affiliation(s)
| | | | | | - Gijsbert H Bol
- Department of Radiotherapy, UMC Utrecht, The Netherlands
| | | | - Roel Bouwmans
- Department of Radiotherapy, UMC Utrecht, The Netherlands
| | - Stefano Mandija
- Department of Radiotherapy, UMC Utrecht, The Netherlands; Computational Imaging Group for MR Diagnostics & Therapy, Center for Image Sciences, UMC Utrecht, The Netherlands
| | | | | | | |
Collapse
|
10
|
Chen X, Yang B, Li J, Zhu J, Ma X, Chen D, Hu Z, Men K, Dai J. A deep-learning method for generating synthetic kV-CT and improving tumor segmentation for helical tomotherapy of nasopharyngeal carcinoma. Phys Med Biol 2021; 66. [PMID: 34700300 DOI: 10.1088/1361-6560/ac3345] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2021] [Accepted: 10/26/2021] [Indexed: 12/11/2022]
Abstract
Objective:Megavoltage computed tomography (MV-CT) is used for setup verification and adaptive radiotherapy in tomotherapy. However, its low contrast and high noise lead to poor image quality. This study aimed to develop a deep-learning-based method to generate synthetic kilovoltage CT (skV-CT) and then evaluate its ability to improve image quality and tumor segmentation.Approach:The planning kV-CT and MV-CT images of 270 patients with nasopharyngeal carcinoma (NPC) treated on an Accuray TomoHD system were used. An improved cycle-consistent adversarial network which used residual blocks as its generator was adopted to learn the mapping between MV-CT and kV-CT and then generate skV-CT from MV-CT. A Catphan 700 phantom and 30 patients with NPC were used to evaluate image quality. The quantitative indices included contrast-to-noise ratio (CNR), uniformity and signal-to-noise ratio (SNR) for the phantom and the structural similarity index measure (SSIM), mean absolute error (MAE), and peak signal-to-noise ratio (PSNR) for patients. Next, we trained three models for segmentation of the clinical target volume (CTV): MV-CT, skV-CT, and MV-CT combined with skV-CT. The segmentation accuracy was compared with indices of the dice similarity coefficient (DSC) and mean distance agreement (MDA).Mainresults:Compared with MV-CT, skV-CT showed significant improvement in CNR (184.0%), image uniformity (34.7%), and SNR (199.0%) in the phantom study and improved SSIM (1.7%), MAE (24.7%), and PSNR (7.5%) in the patient study. For CTV segmentation with only MV-CT, only skV-CT, and MV-CT combined with skV-CT, the DSCs were 0.75 ± 0.04, 0.78 ± 0.04, and 0.79 ± 0.03, respectively, and the MDAs (in mm) were 3.69 ± 0.81, 3.14 ± 0.80, and 2.90 ± 0.62, respectively.Significance:The proposed method improved the image quality of MV-CT and thus tumor segmentation in helical tomotherapy. The method potentially can benefit adaptive radiotherapy.
Collapse
Affiliation(s)
- Xinyuan Chen
- National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100021, People's Republic of China
| | - Bining Yang
- National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100021, People's Republic of China
| | - Jingwen Li
- Cloud Computing and Big Data Research Institute, China Academy of Information and Communications Technology, People's Republic of China
| | - Ji Zhu
- National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100021, People's Republic of China
| | - Xiangyu Ma
- National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100021, People's Republic of China
| | - Deqi Chen
- National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100021, People's Republic of China
| | - Zhihui Hu
- National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100021, People's Republic of China
| | - Kuo Men
- National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100021, People's Republic of China
| | - Jianrong Dai
- National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100021, People's Republic of China
| |
Collapse
|
11
|
Spadea MF, Maspero M, Zaffino P, Seco J. Deep learning based synthetic-CT generation in radiotherapy and PET: A review. Med Phys 2021; 48:6537-6566. [PMID: 34407209 DOI: 10.1002/mp.15150] [Citation(s) in RCA: 96] [Impact Index Per Article: 32.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2021] [Revised: 06/06/2021] [Accepted: 07/13/2021] [Indexed: 01/22/2023] Open
Abstract
Recently,deep learning (DL)-based methods for the generation of synthetic computed tomography (sCT) have received significant research attention as an alternative to classical ones. We present here a systematic review of these methods by grouping them into three categories, according to their clinical applications: (i) to replace computed tomography in magnetic resonance (MR) based treatment planning, (ii) facilitate cone-beam computed tomography based image-guided adaptive radiotherapy, and (iii) derive attenuation maps for the correction of positron emission tomography. Appropriate database searching was performed on journal articles published between January 2014 and December 2020. The DL methods' key characteristics were extracted from each eligible study, and a comprehensive comparison among network architectures and metrics was reported. A detailed review of each category was given, highlighting essential contributions, identifying specific challenges, and summarizing the achievements. Lastly, the statistics of all the cited works from various aspects were analyzed, revealing the popularity and future trends and the potential of DL-based sCT generation. The current status of DL-based sCT generation was evaluated, assessing the clinical readiness of the presented methods.
Collapse
Affiliation(s)
- Maria Francesca Spadea
- Department Experimental and Clinical Medicine, University "Magna Graecia" of Catanzaro, Catanzaro, 88100, Italy
| | - Matteo Maspero
- Division of Imaging & Oncology, Department of Radiotherapy, University Medical Center Utrecht, Heidelberglaan, Utrecht, The Netherlands.,Computational Imaging Group for MR Diagnostics & Therapy, Center for Image Sciences, University Medical Center Utrecht, Heidelberglaan, Utrecht, The Netherlands
| | - Paolo Zaffino
- Department Experimental and Clinical Medicine, University "Magna Graecia" of Catanzaro, Catanzaro, 88100, Italy
| | - Joao Seco
- Division of Biomedical Physics in Radiation Oncology, DKFZ German Cancer Research Center, Heidelberg, Germany.,Department of Physics and Astronomy, Heidelberg University, Heidelberg, Germany
| |
Collapse
|