1
|
Zink K, Baumann KS, Theiss U, Subtil F, Lahrmann S, Eberle F, Adeberg S. Organization and operation of multi particle therapy facilities: the Marburg Ion-Beam Therapy Center, Germany (MIT). HEALTH AND TECHNOLOGY 2024; 14:929-938. [PMID: 39219555 PMCID: PMC11358185 DOI: 10.1007/s12553-024-00881-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2024] [Accepted: 04/23/2024] [Indexed: 09/04/2024]
Abstract
Purpose The Marburg Ion-Beam Therapy Center (MIT) is one of two particle therapy centers in Germany that enables the treatment of patients with both protons and carbon ions. The facility was build by Siemens Healthineers and is one of only two centers worldwide built by Siemens (Marburg, Germany and Shanghai, China). The present report provides an overview of technical and clinical operations as well as research activities at MIT. Methods The MIT was completed in 2011 and uses a synchrotron for accelerating protons and carbon ions up to energies of 250 MeV/u and 430 MeV/u respectively. Three treatment rooms with a fixed horizontal beam-line and one room with a 45 degree beam angle are available. Results Since the start of clinical operations in 2015, around 2.500 patients have been treated at MIT, about 40% with carbon ions and 60% with protons. Currently around 400 patients are treated each year. The majority of the patients suffered from benign and malign CNS tumors (around 40%) followed by head and neck tumors (around 23%). MIT is actively involved in clinical studies with its patients. In addition to clinical operations, there is active research at MIT in the fields of radiation biology and medical physics. The focus is on translational research to improve the treatment of H & N carcinomas and lung cancer (NSCLC). Moreover, intensive work is being carried out on the technical implementation of FLASH irradiation for research purposes. Conclusion The MIT is one of two centers worldwide that were built by Siemens Healtineers and has been successfully in clinical operation since 2015. The service provided by Siemens is guaranteed until 2030, the future after 2030 is currently under discussion.
Collapse
Affiliation(s)
- Klemens Zink
- Marburg Ion-Beam Therapy Center (MIT), Department of Radiotherapy and Radiation Oncology, Marburg University Hospital, Albrecht-Kossel-Strasse, Marburg, 35043 Germany
- Department of Radiotherapy and Radiooncology, Marburg University Hospital, Baldingerstrasse, Marburg, 35043 Germany
- Institute for Medical Physics and Radiation Protection, University of Applied Sciences Giessen, Wiesenstr. 14, Giessen, 35390 Germany
| | - Kilian Simon Baumann
- Marburg Ion-Beam Therapy Center (MIT), Department of Radiotherapy and Radiation Oncology, Marburg University Hospital, Albrecht-Kossel-Strasse, Marburg, 35043 Germany
- Department of Radiotherapy and Radiooncology, Marburg University Hospital, Baldingerstrasse, Marburg, 35043 Germany
- Institute for Medical Physics and Radiation Protection, University of Applied Sciences Giessen, Wiesenstr. 14, Giessen, 35390 Germany
| | - Ulrike Theiss
- Marburg Ion-Beam Therapy Center (MIT), Department of Radiotherapy and Radiation Oncology, Marburg University Hospital, Albrecht-Kossel-Strasse, Marburg, 35043 Germany
- Department of Radiotherapy and Radiooncology, Marburg University Hospital, Baldingerstrasse, Marburg, 35043 Germany
| | - Florentine Subtil
- Department of Radiotherapy and Radiooncology, Marburg University Hospital, Baldingerstrasse, Marburg, 35043 Germany
| | - Sonja Lahrmann
- Marburg Ion-Beam Therapy Center (MIT), Department of Radiotherapy and Radiation Oncology, Marburg University Hospital, Albrecht-Kossel-Strasse, Marburg, 35043 Germany
| | - Fabian Eberle
- Marburg Ion-Beam Therapy Center (MIT), Department of Radiotherapy and Radiation Oncology, Marburg University Hospital, Albrecht-Kossel-Strasse, Marburg, 35043 Germany
- Department of Radiotherapy and Radiooncology, Marburg University Hospital, Baldingerstrasse, Marburg, 35043 Germany
| | - Sebastian Adeberg
- Marburg Ion-Beam Therapy Center (MIT), Department of Radiotherapy and Radiation Oncology, Marburg University Hospital, Albrecht-Kossel-Strasse, Marburg, 35043 Germany
- Department of Radiotherapy and Radiooncology, Marburg University Hospital, Baldingerstrasse, Marburg, 35043 Germany
| |
Collapse
|
2
|
McElligott O, Nikandrovs M, McCavana P, McClean B, León Vintró L. Estimation of the relative biological effectiveness for double strand break induction of clinical kilovoltage beams using Monte Carlo simulations. Med Phys 2024; 51:3796-3805. [PMID: 38588477 DOI: 10.1002/mp.17060] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2023] [Revised: 02/05/2024] [Accepted: 03/06/2024] [Indexed: 04/10/2024] Open
Abstract
BACKGROUND The Relative Biological Effectiveness (RBE) of kilovoltage photon beams has been previously investigated in vitro and in silico using analytical methods. The estimated values range from 1.03 to 1.82 depending on the methodology and beam energies examined. PURPOSE The focus of this work was to independently estimate RBE values for a range of clinically used kilovoltage beams (70-200 kVp) while investigating the suitability of using TOPAS-nBio for this task. METHODS Previously validated spectra of clinical beams were used to generate secondary electron spectra at several depths in a water tank phantom via TOPAS Monte Carlo (MC) simulations. Cell geometry was irradiated with the secondary electrons in TOPAS-nBio MC simulations. The deposited dose and the calculated number of DNA strand breaks were used to estimate RBE values. RESULTS Monoenergetic secondary electron simulations revealed the highest direct and indirect double strand break yield at approximately 20 keV. The average RBE value for the kilovoltage beams was calculated to be 1.14. CONCLUSIONS TOPAS-nBio was successfully used to estimate the RBE values for a range of clinical radiotherapy beams. The calculated value was in agreement with previous estimates, providing confidence in its clinical use in the future.
Collapse
Affiliation(s)
- Oran McElligott
- School of Physics, University College Dublin, Dublin, Ireland
| | - Mihails Nikandrovs
- School of Physics, University College Dublin, Dublin, Ireland
- St. Lukes Radiation Oncology Network, Dublin, Ireland
| | - Patrick McCavana
- St. Lukes Radiation Oncology Network, Dublin, Ireland
- Centre for Physics in Health and Medicine, University College Dublin, Dublin, Ireland
| | - Brendan McClean
- St. Lukes Radiation Oncology Network, Dublin, Ireland
- Centre for Physics in Health and Medicine, University College Dublin, Dublin, Ireland
| | - Luis León Vintró
- School of Physics, University College Dublin, Dublin, Ireland
- St. Lukes Radiation Oncology Network, Dublin, Ireland
- Centre for Physics in Health and Medicine, University College Dublin, Dublin, Ireland
| |
Collapse
|
3
|
Derksen L, Adeberg S, Zink K, Baumann KS. Comparison of two methods simulating inter-track interactions using the radiobiological Monte Carlo toolkit TOPAS-nBio. Phys Med Biol 2024; 69:03NT01. [PMID: 38198700 DOI: 10.1088/1361-6560/ad1cf4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2023] [Accepted: 01/10/2024] [Indexed: 01/12/2024]
Abstract
Objective.To compare two independently developed methods that enable modelling inter-track interactions in TOPAS-nBio by examining the yield of radiolytic species in radiobiological Monte Carlo track structure simulations. One method uses a phase space file to assign more than one primary to one event, allowing for inter-track interaction between these primary particles. This method has previously been developed by this working group and published earlier. Using the other method, chemical reactions are simulated based on a new version of the independent reaction time approach to allow inter-track interactions.Approach.G-values were calculated and compared using both methods for different numbers of tracks able to undergo inter-track interactions.Main results.Differences in theG-values simulated with the two methods strongly depend on the molecule type, and deviations can range up to 3.9% (H2O2), although, on average, the deviations are smaller than 1.5%.Significance.Both methods seem to be suitable for simulating inter-track interactions, as they provide comparableG-values even though both techniques were developed independently of each other.
Collapse
Affiliation(s)
- Larissa Derksen
- University of Applied Sciences, Institute of Medical Physics and Radiation Protection, Giessen, Germany
| | - Sebastian Adeberg
- Marburg University Hospital, Department of Radiotherapy and Radiation Oncology, Marburg, Germany
- Marburg Ion-Beam Therapy Center (MIT), Department of Radiotherapy and Radiation Oncology, Marburg University Hospital, Marburg, Germany
- University Cancer Center, Frankfurt-Marburg, Germany
| | - Klemens Zink
- University of Applied Sciences, Institute of Medical Physics and Radiation Protection, Giessen, Germany
- Marburg University Hospital, Department of Radiotherapy and Radiation Oncology, Marburg, Germany
- Marburg Ion-Beam Therapy Center (MIT), Department of Radiotherapy and Radiation Oncology, Marburg University Hospital, Marburg, Germany
| | - Kilian-Simon Baumann
- University of Applied Sciences, Institute of Medical Physics and Radiation Protection, Giessen, Germany
- Marburg University Hospital, Department of Radiotherapy and Radiation Oncology, Marburg, Germany
- Marburg Ion-Beam Therapy Center (MIT), Department of Radiotherapy and Radiation Oncology, Marburg University Hospital, Marburg, Germany
| |
Collapse
|
4
|
Rumiantcev M, Li WB, Lindner S, Liubchenko G, Resch S, Bartenstein P, Ziegler SI, Böning G, Delker A. Estimation of relative biological effectiveness of 225Ac compared to 177Lu during [ 225Ac]Ac-PSMA and [ 177Lu]Lu-PSMA radiopharmaceutical therapy using TOPAS/TOPAS-nBio/MEDRAS. EJNMMI Phys 2023; 10:53. [PMID: 37695374 PMCID: PMC10495309 DOI: 10.1186/s40658-023-00567-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2023] [Accepted: 08/07/2023] [Indexed: 09/12/2023] Open
Abstract
AIM Over recent years, [225Ac]Ac-PSMA and [177Lu]Lu-PSMA radiopharmaceutical therapy have evolved as a promising treatment option for advanced prostate cancer. Especially for alpha particle emitter treatments, there is still a need for improving dosimetry, which requires accurate values of relative biological effectiveness (RBE). To achieve that, consideration of DNA damages in the cell nucleus and knowledge of the energy deposition in the location of the DNA at the nanometer scale are required. Monte Carlo particle track structure simulations provide access to interactions at this level. The aim of this study was to estimate the RBE of 225Ac compared to 177Lu. The initial damage distribution after radionuclide decay and the residual damage after DNA repair were considered. METHODS This study employed the TOol for PArtcile Simulation (TOPAS) based on the Geant4 simulation toolkit. Simulation of the nuclear DNA and damage scoring were performed using the TOPAS-nBio extension of TOPAS. DNA repair was modeled utilizing the Python-based program MEDRAS (Mechanistic DNA Repair and Survival). Five different cell geometries of equal volume and two radionuclide internalization assumptions as well as two cell arrangement scenarios were investigated. The radionuclide activity (number of source points) was adopted based on SPECT images of patients undergoing the above-mentioned therapies. RESULTS Based on the simulated dose-effect curves, the RBE of 225Ac compared to 177Lu was determined in a wide range of absorbed doses to the nucleus. In the case of spherical geometry, 3D cell arrangement and full radionuclide internalization, the RBE based on the initial damage had a constant value of approximately 2.14. Accounting for damage repair resulted in RBE values ranging between 9.38 and 1.46 for 225Ac absorbed doses to the nucleus between 0 and 50 Gy, respectively. CONCLUSION In this work, the consideration of DNA repair of the damage from [225Ac]Ac-PSMA and [177Lu]Lu-PSMA revealed a dose dependency of the RBE. Hence, this work suggested that DNA repair is an important aspect to understand response to different radiation qualities.
Collapse
Affiliation(s)
- Mikhail Rumiantcev
- Department of Nuclear Medicine, LMU University Hospital, LMU Munich, Munich, Germany.
| | - Wei Bo Li
- Federal Office for Radiation Protection, Medical and Occupational Radiation Protection, Oberschleißheim, Germany
| | - Simon Lindner
- Department of Nuclear Medicine, LMU University Hospital, LMU Munich, Munich, Germany
| | - Grigory Liubchenko
- Department of Nuclear Medicine, LMU University Hospital, LMU Munich, Munich, Germany
| | - Sandra Resch
- Department of Nuclear Medicine, LMU University Hospital, LMU Munich, Munich, Germany
| | - Peter Bartenstein
- Department of Nuclear Medicine, LMU University Hospital, LMU Munich, Munich, Germany
| | - Sibylle I Ziegler
- Department of Nuclear Medicine, LMU University Hospital, LMU Munich, Munich, Germany
| | - Guido Böning
- Department of Nuclear Medicine, LMU University Hospital, LMU Munich, Munich, Germany
| | - Astrid Delker
- Department of Nuclear Medicine, LMU University Hospital, LMU Munich, Munich, Germany
| |
Collapse
|