1
|
van der Ster BJP, Westerhof BE, Stok WJ, van Lieshout JJ. Detecting central hypovolemia in simulated hypovolemic shock by automated feature extraction with principal component analysis. Physiol Rep 2019; 6:e13895. [PMID: 30488597 PMCID: PMC6429974 DOI: 10.14814/phy2.13895] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2018] [Revised: 09/10/2018] [Accepted: 09/11/2018] [Indexed: 11/24/2022] Open
Abstract
Assessment of the volume status by blood pressure (BP) monitoring is difficult, since baroreflex control of BP makes it insensitive to blood loss up to about one liter. We hypothesized that a machine learning model recognizes the progression of central hypovolemia toward presyncope by extracting information of the noninvasive blood pressure waveform parametrized through principal component analysis. This was tested in healthy volunteers exposed to simulated hemorrhage by lower body negative pressure (LBNP). Fifty‐six healthy volunteers were subjected to progressive central hypovolemia. A support vector machine was trained on the blood pressure waveform. Three classes of progressive stages of hypovolemia were defined. The model was optimized for the number of principal components and regularization parameter for penalizing misclassification (cost): C. Model performance was expressed as accuracy, mean squared error (MSE), and kappa statistic (inter‐rater agreement). Forty‐six subjects developed presyncope of which 41 showed an increase in model classification severity from baseline to presyncope. In five of the remaining nine subjects (1 was excluded) it stagnated. Classification of samples during baseline and end‐stage LBNP had the highest accuracy (95% and 50%, respectively). Baseline and first stage of LBNP demonstrated the lowest MSE (0.01 respectively 0.32). Model MSE and accuracy did not improve for C values exceeding 0.01. Adding more than five principal components did not further improve accuracy or MSE. Increment in kappa halted after 10 principal components had been added. Automated feature extraction of the blood pressure waveform allows modeling of progressive hypovolemia with a support vector machine. The model distinguishes classes between baseline and presyncope.
Collapse
Affiliation(s)
- Björn J P van der Ster
- Department of Internal Medicine, Academic Medical Center, University of Amsterdam, Amsterdam, the Netherlands.,Department of Medical Biology, Academic Medical Center, University of Amsterdam, Amsterdam, the Netherlands.,Laboratory for Clinical Cardiovascular Physiology, Center for Heart Failure Research, Academic Medical Center, Amsterdam, the Netherlands
| | - Berend E Westerhof
- Department of Medical Biology, Academic Medical Center, University of Amsterdam, Amsterdam, the Netherlands.,Laboratory for Clinical Cardiovascular Physiology, Center for Heart Failure Research, Academic Medical Center, Amsterdam, the Netherlands.,Department of Pulmonary Diseases, Amsterdam Cardiovascular Sciences, VU University Medical Center, Amsterdam, the Netherlands
| | - Wim J Stok
- Department of Medical Biology, Academic Medical Center, University of Amsterdam, Amsterdam, the Netherlands.,Laboratory for Clinical Cardiovascular Physiology, Center for Heart Failure Research, Academic Medical Center, Amsterdam, the Netherlands
| | - Johannes J van Lieshout
- Department of Internal Medicine, Academic Medical Center, University of Amsterdam, Amsterdam, the Netherlands.,Department of Medical Biology, Academic Medical Center, University of Amsterdam, Amsterdam, the Netherlands.,Laboratory for Clinical Cardiovascular Physiology, Center for Heart Failure Research, Academic Medical Center, Amsterdam, the Netherlands.,MRC/Arthritis Research, UK Centre for Musculoskeletal Ageing Research, School of Life Sciences, the Medical School, University of Nottingham Medical School, Queen's Medical Centre, Nottingham, United Kingdom
| |
Collapse
|
2
|
van der Ster BJP, Bennis FC, Delhaas T, Westerhof BE, Stok WJ, van Lieshout JJ. Support Vector Machine Based Monitoring of Cardio-Cerebrovascular Reserve during Simulated Hemorrhage. Front Physiol 2018; 8:1057. [PMID: 29354062 PMCID: PMC5761201 DOI: 10.3389/fphys.2017.01057] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2017] [Accepted: 12/04/2017] [Indexed: 12/28/2022] Open
Abstract
Introduction: In the initial phase of hypovolemic shock, mean blood pressure (BP) is maintained by sympathetically mediated vasoconstriction rendering BP monitoring insensitive to detect blood loss early. Late detection can result in reduced tissue oxygenation and eventually cellular death. We hypothesized that a machine learning algorithm that interprets currently used and new hemodynamic parameters could facilitate in the detection of impending hypovolemic shock. Method: In 42 (27 female) young [mean (sd): 24 (4) years], healthy subjects central blood volume (CBV) was progressively reduced by application of −50 mmHg lower body negative pressure until the onset of pre-syncope. A support vector machine was trained to classify samples into normovolemia (class 0), initial phase of CBV reduction (class 1) or advanced CBV reduction (class 2). Nine models making use of different features were computed to compare sensitivity and specificity of different non-invasive hemodynamic derived signals. Model features included: volumetric hemodynamic parameters (stroke volume and cardiac output), BP curve dynamics, near-infrared spectroscopy determined cortical brain oxygenation, end-tidal carbon dioxide pressure, thoracic bio-impedance, and middle cerebral artery transcranial Doppler (TCD) blood flow velocity. Model performance was tested by quantifying the predictions with three methods: sensitivity and specificity, absolute error, and quantification of the log odds ratio of class 2 vs. class 0 probability estimates. Results: The combination with maximal sensitivity and specificity for classes 1 and 2 was found for the model comprising volumetric features (class 1: 0.73–0.98 and class 2: 0.56–0.96). Overall lowest model error was found for the models comprising TCD curve hemodynamics. Using probability estimates the best combination of sensitivity for class 1 (0.67) and specificity (0.87) was found for the model that contained the TCD cerebral blood flow velocity derived pulse height. The highest combination for class 2 was found for the model with the volumetric features (0.72 and 0.91). Conclusion: The most sensitive models for the detection of advanced CBV reduction comprised data that describe features from volumetric parameters and from cerebral blood flow velocity hemodynamics. In a validated model of hemorrhage in humans these parameters provide the best indication of the progression of central hypovolemia.
Collapse
Affiliation(s)
- Björn J P van der Ster
- Department of Internal Medicine, Academic Medical Center, University of Amsterdam, Amsterdam, Netherlands.,Department of Medical Biology, Academic Medical Center, University of Amsterdam, Amsterdam, Netherlands.,Laboratory for Clinical Cardiovascular Physiology, Center for Heart Failure Research, Academic Medical Center, Amsterdam, Netherlands
| | - Frank C Bennis
- Department of Biomedical Engineering, Maastricht University, Maastricht, Netherlands.,MHeNS School for Mental Health and Neuroscience, Maastricht University, Maastricht, Netherlands
| | - Tammo Delhaas
- Department of Biomedical Engineering, Maastricht University, Maastricht, Netherlands.,CARIM School for Cardiovascular Diseases, Maastricht University, Maastricht, Netherlands
| | - Berend E Westerhof
- Department of Medical Biology, Academic Medical Center, University of Amsterdam, Amsterdam, Netherlands.,Laboratory for Clinical Cardiovascular Physiology, Center for Heart Failure Research, Academic Medical Center, Amsterdam, Netherlands.,Department of Pulmonary Diseases, Institute for Cardiovascular Research, ICaR-VU, VU University Medical Center, Amsterdam, Netherlands
| | - Wim J Stok
- Department of Medical Biology, Academic Medical Center, University of Amsterdam, Amsterdam, Netherlands.,Laboratory for Clinical Cardiovascular Physiology, Center for Heart Failure Research, Academic Medical Center, Amsterdam, Netherlands
| | - Johannes J van Lieshout
- Department of Internal Medicine, Academic Medical Center, University of Amsterdam, Amsterdam, Netherlands.,Department of Medical Biology, Academic Medical Center, University of Amsterdam, Amsterdam, Netherlands.,Laboratory for Clinical Cardiovascular Physiology, Center for Heart Failure Research, Academic Medical Center, Amsterdam, Netherlands.,MRC/Arthritis Research UK Centre for Musculoskeletal Ageing Research, School of Life Sciences, The Medical School, University of Nottingham Medical School, Queen's Medical Centre, Nottingham, United Kingdom
| |
Collapse
|