Bachir W, Ismael FS, Alaineya NHA. Laser spectroscopic method for remote sensing of respiratory rate. Phys Eng Sci Med 2023; 46:1249-1258. [PMID: 37358781 PMCID: PMC10480269 DOI: 10.1007/s13246-023-01292-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2023] [Accepted: 06/16/2023] [Indexed: 06/27/2023]
Abstract
Noncontact sensing methods for measuring vital signs have recently gained interest, particularly for long-term monitoring. This study introduces a new method for measuring respiratory rate remotely. The proposed method is based on the reflection of a laser beam off a striped card attached to a moving platform simulating chest wall displacements. A wide range of frequencies (n = 35) from 0.06 to 2.2 Hz corresponding to both normal and pathological human respiratory rates were simulated using a moving mechanical platform. Reflected spectra (n = 105) were collected by a spectrometer in a dynamic mode. Fourier analysis was performed to retrieve the breathing frequency. The results show a striking agreement between measurements and reference frequencies. The results also show that low frequencies corresponding to respiratory rates can be detected with high accuracy (uncertainty is well below 5%). A validation test of the measuring method on a human subject demonstrated a great potential for remote respiration rate monitoring of adults and neonates in a clinical environment.
Collapse
Affiliation(s)
- Wesam Bachir
- Institute of Metrology and Biomedical Engineering, Faculty of Mechatronics, Warsaw University of Technology, Św. A. Boboli 8 St, 02-525, Warsaw, Poland.
- Biomedical Photonics Laboratory, Higher Institute for Laser Research and Applications, Damascus University, Damascus, Syria.
| | - Fatimah Samie Ismael
- Biomedical Photonics Laboratory, Higher Institute for Laser Research and Applications, Damascus University, Damascus, Syria
| | - Nour Hasan Arry Alaineya
- Biomedical Photonics Laboratory, Higher Institute for Laser Research and Applications, Damascus University, Damascus, Syria
| |
Collapse
|
2
|
Coleman J, Ginsburg AS, Macharia WM, Ochieng R, Chomba D, Zhou G, Dunsmuir D, Karlen W, Ansermino JM. Assessment of neonatal respiratory rate variability. J Clin Monit Comput 2022; 36:1869-1879. [PMID: 35332406 PMCID: PMC9637627 DOI: 10.1007/s10877-022-00840-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2021] [Accepted: 03/02/2022] [Indexed: 11/30/2022]
Abstract
Accurate measurement of respiratory rate (RR) in neonates is challenging due to high neonatal RR variability (RRV). There is growing evidence that RRV measurement could inform and guide neonatal care. We sought to quantify neonatal RRV during a clinical study in which we compared multiparameter continuous physiological monitoring (MCPM) devices. Measurements of capnography-recorded exhaled carbon dioxide across 60-s epochs were collected from neonates admitted to the neonatal unit at Aga Khan University-Nairobi hospital. Breaths were manually counted from capnograms and using an automated signal detection algorithm which also calculated mean and median RR for each epoch. Outcome measures were between- and within-neonate RRV, between- and within-epoch RRV, and 95% limits of agreement, bias, and root-mean-square deviation. Twenty-seven neonates were included, with 130 epochs analysed. Mean manual breath count (MBC) was 48 breaths per minute. Median RRV ranged from 11.5% (interquartile range (IQR) 6.8-18.9%) to 28.1% (IQR 23.5-36.7%). Bias and limits of agreement for MBC vs algorithm-derived breath count, MBC vs algorithm-derived median breath rate, MBC vs algorithm-derived mean breath rate were - 0.5 (- 2.7, 1.66), - 3.16 (- 12.12, 5.8), and - 3.99 (- 11.3, 3.32), respectively. The marked RRV highlights the challenge of performing accurate RR measurements in neonates. More research is required to optimize the use of RRV to improve care. When evaluating MCPM devices, accuracy thresholds should be less stringent in newborns due to increased RRV. Lastly, median RR, which discounts the impact of extreme outliers, may be more reflective of the underlying physiological control of breathing.
Collapse
Affiliation(s)
- Jesse Coleman
- Evaluation of Technologies for Neonates in Africa (ETNA), Nairobi, Kenya.
- Centre for International Child Health, 305 - 4088 Cambie Street, Vancouver, BC, V5Z 2X8, Canada.
| | | | | | | | - Dorothy Chomba
- Department of Pediatrics, Aga Khan University, Nairobi, Kenya
| | - Guohai Zhou
- Center for Clinical Investigation, Brigham and Women's Hospital, Boston, MA, USA
| | - Dustin Dunsmuir
- Anesthesiology, Pharmacology & Therapeutics, The University of British Columbia, Vancouver, BC, Canada
| | - Walter Karlen
- Mobile Health Systems Lab, Department of Health Sciences and Technology, ETH Zurich, Zurich, Switzerland
| | - J Mark Ansermino
- Anesthesiology, Pharmacology & Therapeutics, The University of British Columbia, Vancouver, BC, Canada
| |
Collapse
|
3
|
Prins W, Stamatelou E, Dellimore K, Likumbo A, Kafulafula E, Langton J, Njirammadzi J, Mwenisungo J, Msukwa T, Calis J, van Sloun R, Bierling B. A U - Net Deep Learning Model for Infant Heart Rate Estimation from Ballistography . ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2022; 2022:1919-1922. [PMID: 36086528 DOI: 10.1109/embc48229.2022.9871797] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Ballistography(BSG) is a non-intrusive and low- cost alternative to electrocardiography (ECG) for heart rate (HR) monitoring in infants. Due to the inter-patient variance and susceptibility to noise, heartbeat detection in the BSG waveform remains a challenge. The aim of this study was to estimate HR from a bed-based pressure mat BSG signal using a deep learning approach. We trained a U-Net deep neural network through supervised learning by deriving ground truth as the location of the heartbeats from simultaneously recorded ECG signals after peak matching. For improved generalization, we modified an existing U - Net to include an IC-layer. A predictive performance of 80% was achieved using the U-Net without the IC-layer. The inclusion of the IC-layer, while improving the generalization ability of the model to detect heartbeats, did not improve the HR estimation performance.
Collapse
|
4
|
Lorato I, Stuijk S, Meftah M, Kommers D, Andriessen P, van Pul C, de Haan G. Automatic Separation of Respiratory Flow from Motion in Thermal Videos for Infant Apnea Detection. SENSORS (BASEL, SWITZERLAND) 2021; 21:6306. [PMID: 34577513 PMCID: PMC8472592 DOI: 10.3390/s21186306] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/28/2021] [Revised: 09/16/2021] [Accepted: 09/18/2021] [Indexed: 02/07/2023]
Abstract
Both Respiratory Flow (RF) and Respiratory Motion (RM) are visible in thermal recordings of infants. Monitoring these two signals usually requires landmark detection for the selection of a region of interest. Other approaches combine respiratory signals coming from both RF and RM, obtaining a Mixed Respiratory (MR) signal. The detection and classification of apneas, particularly common in preterm infants with low birth weight, would benefit from monitoring both RF and RM, or MR, signals. Therefore, we propose in this work an automatic RF pixel detector not based on facial/body landmarks. The method is based on the property of RF pixels in thermal videos, which are in areas with a smooth circular gradient. We defined 5 features combined with the use of a bank of Gabor filters that together allow selection of the RF pixels. The algorithm was tested on thermal recordings of 9 infants amounting to a total of 132 min acquired in a neonatal ward. On average the percentage of correctly identified RF pixels was 84%. Obstructive Apneas (OAs) were simulated as a proof of concept to prove the advantage in monitoring the RF signal compared to the MR signal. The sensitivity in the simulated OA detection improved for the RF signal reaching 73% against the 23% of the MR signal. Overall, the method yielded promising results, although the positioning and number of cameras used could be further optimized for optimal RF visibility.
Collapse
Affiliation(s)
- Ilde Lorato
- Department of Electrical Engineering, Eindhoven University of Technology, 5612 AZ Eindhoven, The Netherlands; (S.S.); (G.d.H.)
| | - Sander Stuijk
- Department of Electrical Engineering, Eindhoven University of Technology, 5612 AZ Eindhoven, The Netherlands; (S.S.); (G.d.H.)
| | - Mohammed Meftah
- Department of Family Care Solutions, Philips Research, 5656 AE Eindhoven, The Netherlands;
| | - Deedee Kommers
- Department of Neonatology, Máxima Medical Centre, 5504 DB Veldhoven, The Netherlands; (D.K.); (P.A.)
- Department of Applied Physics, Eindhoven University of Technology, 5612 AZ Eindhoven, The Netherlands;
| | - Peter Andriessen
- Department of Neonatology, Máxima Medical Centre, 5504 DB Veldhoven, The Netherlands; (D.K.); (P.A.)
- Department of Applied Physics, Eindhoven University of Technology, 5612 AZ Eindhoven, The Netherlands;
| | - Carola van Pul
- Department of Applied Physics, Eindhoven University of Technology, 5612 AZ Eindhoven, The Netherlands;
- Department of Clinical Physics, Máxima Medical Centre, 5504 DB Veldhoven, The Netherlands
| | - Gerard de Haan
- Department of Electrical Engineering, Eindhoven University of Technology, 5612 AZ Eindhoven, The Netherlands; (S.S.); (G.d.H.)
| |
Collapse
|
5
|
Cay G, Ravichandran V, Saikia MJ, Hoffman L, Laptook A, Padbury J, Salisbury AL, Gitelson-Kahn A, Venkatasubramanian K, Shahriari Y, Mankodiya K. An E-Textile Respiration Sensing System for NICU Monitoring: Design and Validation. JOURNAL OF SIGNAL PROCESSING SYSTEMS 2021; 94:543-557. [PMID: 34306304 PMCID: PMC8286045 DOI: 10.1007/s11265-021-01669-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/06/2020] [Revised: 04/16/2021] [Accepted: 05/02/2021] [Indexed: 06/13/2023]
Abstract
The world is witnessing a rising number of preterm infants who are at significant risk of medical conditions. These infants require continuous care in Neonatal Intensive Care Units (NICU). Medical parameters are continuously monitored in premature infants in the NICU using a set of wired, sticky electrodes attached to the body. Medical adhesives used on the electrodes can be harmful to the baby, causing skin injuries, discomfort, and irritation. In addition, respiration rate (RR) monitoring in the NICU faces challenges of accuracy and clinical quality because RR is extracted from electrocardiogram (ECG). This research paper presents a design and validation of a smart textile pressure sensor system that addresses the existing challenges of medical monitoring in NICU. We designed two e-textile, piezoresistive pressure sensors made of Velostat for noninvasive RR monitoring; one was hand-stitched on a mattress topper material, and the other was embroidered on a denim fabric using an industrial embroidery machine. We developed a data acquisition system for validation experiments conducted on a high-fidelity, programmable NICU baby mannequin. We designed a signal processing pipeline to convert raw time-series signals into parameters including RR, rise and fall time, and comparison metrics. The results of the experiments showed that the relative accuracies of hand-stitched sensors were 98.68 (top sensor) and 98.07 (bottom sensor), while the accuracies of embroidered sensors were 99.37 (left sensor) and 99.39 (right sensor) for the 60 BrPM test case. The presented prototype system shows promising results and demands more research on textile design, human factors, and human experimentation.
Collapse
Affiliation(s)
- Gozde Cay
- Department of Electrical, Computer, and Biomedical Engineering, University of Rhode Island, Kingston, RI USA
| | - Vignesh Ravichandran
- Department of Electrical, Computer, and Biomedical Engineering, University of Rhode Island, Kingston, RI USA
| | - Manob Jyoti Saikia
- Department of Electrical, Computer, and Biomedical Engineering, University of Rhode Island, Kingston, RI USA
- Center for Applied Brain and Cognitive Sciences, Tufts University, Medford, MA USA
| | - Laurie Hoffman
- Pediatrics, Women and Infants Hospital, Providence, RI USA
| | - Abbot Laptook
- Pediatrics, Women and Infants Hospital, Providence, RI USA
| | - James Padbury
- Pediatrics, Women and Infants Hospital, Providence, RI USA
| | - Amy L. Salisbury
- Pediatrics, Women and Infants Hospital, Providence, RI USA
- School of Nursing, Virginia Commonwealth University, Richmond, VA USA
| | - Anna Gitelson-Kahn
- Department of Textiles, Rhode Island School of Design, Providence, RI USA
| | | | - Yalda Shahriari
- Department of Electrical, Computer, and Biomedical Engineering, University of Rhode Island, Kingston, RI USA
| | - Kunal Mankodiya
- Department of Electrical, Computer, and Biomedical Engineering, University of Rhode Island, Kingston, RI USA
| |
Collapse
|
6
|
Lorato I, Stuijk S, Meftah M, Kommers D, Andriessen P, van Pul C, de Haan G. Towards Continuous Camera-Based Respiration Monitoring in Infants. SENSORS (BASEL, SWITZERLAND) 2021; 21:2268. [PMID: 33804913 PMCID: PMC8036870 DOI: 10.3390/s21072268] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/31/2021] [Revised: 03/19/2021] [Accepted: 03/21/2021] [Indexed: 02/06/2023]
Abstract
Aiming at continuous unobtrusive respiration monitoring, motion robustness is paramount. However, some types of motion can completely hide the respiration information and the detection of these events is required to avoid incorrect rate estimations. Therefore, this work proposes a motion detector optimized to specifically detect severe motion of infants combined with a respiration rate detection strategy based on automatic pixels selection, which proved to be robust to motion of the infants involving head and limbs. A dataset including both thermal and RGB (Red Green Blue) videos was used amounting to a total of 43 h acquired on 17 infants. The method was successfully applied to both RGB and thermal videos and compared to the chest impedance signal. The Mean Absolute Error (MAE) in segments where some motion is present was 1.16 and 1.97 breaths/min higher than the MAE in the ideal moments where the infants were still for testing and validation set, respectively. Overall, the average MAE on the testing and validation set are 3.31 breaths/min and 5.36 breaths/min, using 64.00% and 69.65% of the included video segments (segments containing events such as interventions were excluded based on a manual annotation), respectively. Moreover, we highlight challenges that need to be overcome for continuous camera-based respiration monitoring. The method can be applied to different camera modalities, does not require skin visibility, and is robust to some motion of the infants.
Collapse
Affiliation(s)
- Ilde Lorato
- Department of Electrical Engineering, Eindhoven University of Technology, 5612 AZ Eindhoven, The Netherlands; (S.S.); (G.d.H.)
| | - Sander Stuijk
- Department of Electrical Engineering, Eindhoven University of Technology, 5612 AZ Eindhoven, The Netherlands; (S.S.); (G.d.H.)
| | - Mohammed Meftah
- Department of Family Care Solutions, Philips Research, 5656 AE Eindhoven, The Netherlands;
| | - Deedee Kommers
- Department of Neonatology, Maxima Medical Centre, 5504 DB Veldhoven, The Netherlands; (D.K.); (P.A.)
- Department of Applied Physics, Eindhoven University of Technology, 5612 AZ Eindhoven, The Netherlands;
| | - Peter Andriessen
- Department of Neonatology, Maxima Medical Centre, 5504 DB Veldhoven, The Netherlands; (D.K.); (P.A.)
- Department of Applied Physics, Eindhoven University of Technology, 5612 AZ Eindhoven, The Netherlands;
| | - Carola van Pul
- Department of Applied Physics, Eindhoven University of Technology, 5612 AZ Eindhoven, The Netherlands;
- Department of Clinical Physics, Maxima Medical Centre, 5504 DB Veldhoven, The Netherlands
| | - Gerard de Haan
- Department of Electrical Engineering, Eindhoven University of Technology, 5612 AZ Eindhoven, The Netherlands; (S.S.); (G.d.H.)
| |
Collapse
|
7
|
Maurya L, Kaur P, Chawla D, Mahapatra P. Non-contact breathing rate monitoring in newborns: A review. Comput Biol Med 2021; 132:104321. [PMID: 33773194 DOI: 10.1016/j.compbiomed.2021.104321] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2021] [Revised: 03/04/2021] [Accepted: 03/04/2021] [Indexed: 02/07/2023]
Abstract
The neonatal period - the first 4 weeks of life - is the most critical time for a child's survival. Breathing rate is a vital indicator of the health condition and requires continuous monitoring in case of sickness or preterm birth. Breathing movements can be counted by contact and non-contact methods. In the case of newborn infants, the non-contact breathing rate monitoring need is high, as a contact-based approach may interfere while providing care and is subject to interference by non-breathing movements. This review article delivers a factual summary, and describes the methods and processing involved in non-contact based breathing rate monitoring. The article also provides the advantages, limitations, and clinical applications of these methods. Additionally, signal processing, feasibility, and future direction of different non-contact neonatal breathing rate monitoring are discussed.
Collapse
Affiliation(s)
- Lalit Maurya
- Academy of Scientific and Innovative Research (AcSIR), Ghaziabad, 201002, India; CSIR-Central Scientific Instruments Organisation (CSIR-CSIO), Sector 30-C, Chandigarh, 160030, India.
| | - Pavleen Kaur
- CSIR-Central Scientific Instruments Organisation (CSIR-CSIO), Sector 30-C, Chandigarh, 160030, India; Department of Biomedical Engineering, SRM University Delhi NCR, Sonepat, Haryana, India.
| | - Deepak Chawla
- Department of Neonatology, Government Medical College & Hospital (GMCH), Chandigarh, 160030, India.
| | - Prasant Mahapatra
- Academy of Scientific and Innovative Research (AcSIR), Ghaziabad, 201002, India; CSIR-Central Scientific Instruments Organisation (CSIR-CSIO), Sector 30-C, Chandigarh, 160030, India.
| |
Collapse
|
8
|
Chiera M, Cerritelli F, Casini A, Barsotti N, Boschiero D, Cavigioli F, Corti CG, Manzotti A. Heart Rate Variability in the Perinatal Period: A Critical and Conceptual Review. Front Neurosci 2020; 14:561186. [PMID: 33071738 PMCID: PMC7544983 DOI: 10.3389/fnins.2020.561186] [Citation(s) in RCA: 53] [Impact Index Per Article: 10.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2020] [Accepted: 08/28/2020] [Indexed: 12/18/2022] Open
Abstract
Neonatal intensive care units (NICUs) greatly expand the use of technology. There is a need to accurately diagnose discomfort, pain, and complications, such as sepsis, mainly before they occur. While specific treatments are possible, they are often time-consuming, invasive, or painful, with detrimental effects for the development of the infant. In the last 40 years, heart rate variability (HRV) has emerged as a non-invasive measurement to monitor newborns and infants, but it still is underused. Hence, the present paper aims to review the utility of HRV in neonatology and the instruments available to assess it, showing how HRV could be an innovative tool in the years to come. When continuously monitored, HRV could help assess the baby’s overall wellbeing and neurological development to detect stress-/pain-related behaviors or pathological conditions, such as respiratory distress syndrome and hyperbilirubinemia, to address when to perform procedures to reduce the baby’s stress/pain and interventions, such as therapeutic hypothermia, and to avoid severe complications, such as sepsis and necrotizing enterocolitis, thus reducing mortality. Based on literature and previous experiences, the first step to efficiently introduce HRV in the NICUs could consist in a monitoring system that uses photoplethysmography, which is low-cost and non-invasive, and displays one or a few metrics with good clinical utility. However, to fully harness HRV clinical potential and to greatly improve neonatal care, the monitoring systems will have to rely on modern bioinformatics (machine learning and artificial intelligence algorithms), which could easily integrate infant’s HRV metrics, vital signs, and especially past history, thus elaborating models capable to efficiently monitor and predict the infant’s clinical conditions. For this reason, hospitals and institutions will have to establish tight collaborations between the obstetric, neonatal, and pediatric departments: this way, healthcare would truly improve in every stage of the perinatal period (from conception to the first years of life), since information about patients’ health would flow freely among different professionals, and high-quality research could be performed integrating the data recorded in those departments.
Collapse
Affiliation(s)
- Marco Chiera
- Research and Assistance for Infants to Support Experience Lab, Foundation Center for Osteopathic Medicine Collaboration, Pescara, Italy.,Research Commission on Manual Therapies and Mind-Body Disciplines, Societ Italiana di Psico Neuro Endocrino Immunologia, Rome, Italy
| | - Francesco Cerritelli
- Research and Assistance for Infants to Support Experience Lab, Foundation Center for Osteopathic Medicine Collaboration, Pescara, Italy
| | - Alessandro Casini
- Research and Assistance for Infants to Support Experience Lab, Foundation Center for Osteopathic Medicine Collaboration, Pescara, Italy
| | - Nicola Barsotti
- Research and Assistance for Infants to Support Experience Lab, Foundation Center for Osteopathic Medicine Collaboration, Pescara, Italy.,Research Commission on Manual Therapies and Mind-Body Disciplines, Societ Italiana di Psico Neuro Endocrino Immunologia, Rome, Italy
| | | | - Francesco Cavigioli
- Neonatal Intensive Care Unit, "V. Buzzi" Children's Hospital, Azienda Socio Sanitaria Territoriale Fatebenefratelli-Sacco, Milan, Italy
| | - Carla G Corti
- Pediatric Cardiology Unit-Pediatric Department, Azienda Socio Sanitaria Territoriale Fatebenefratelli-Sacco, Milan, Italy
| | - Andrea Manzotti
- Research and Assistance for Infants to Support Experience Lab, Foundation Center for Osteopathic Medicine Collaboration, Pescara, Italy.,Neonatal Intensive Care Unit, "V. Buzzi" Children's Hospital, Azienda Socio Sanitaria Territoriale Fatebenefratelli-Sacco, Milan, Italy.,Research Department, SOMA, Istituto Osteopatia Milano, Milan, Italy
| |
Collapse
|
9
|
Sensing Systems for Respiration Monitoring: A Technical Systematic Review. SENSORS 2020; 20:s20185446. [PMID: 32972028 PMCID: PMC7570710 DOI: 10.3390/s20185446] [Citation(s) in RCA: 38] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/09/2020] [Revised: 09/16/2020] [Accepted: 09/16/2020] [Indexed: 02/06/2023]
Abstract
Respiratory monitoring is essential in sleep studies, sport training, patient monitoring, or health at work, among other applications. This paper presents a comprehensive systematic review of respiration sensing systems. After several systematic searches in scientific repositories, the 198 most relevant papers in this field were analyzed in detail. Different items were examined: sensing technique and sensor, respiration parameter, sensor location and size, general system setup, communication protocol, processing station, energy autonomy and power consumption, sensor validation, processing algorithm, performance evaluation, and analysis software. As a result, several trends and the remaining research challenges of respiration sensors were identified. Long-term evaluations and usability tests should be performed. Researchers designed custom experiments to validate the sensing systems, making it difficult to compare results. Therefore, another challenge is to have a common validation framework to fairly compare sensor performance. The implementation of energy-saving strategies, the incorporation of energy harvesting techniques, the calculation of volume parameters of breathing, or the effective integration of respiration sensors into clothing are other remaining research efforts. Addressing these and other challenges outlined in the paper is a required step to obtain a feasible, robust, affordable, and unobtrusive respiration sensing system.
Collapse
|
10
|
Lorato I, Stuijk S, Meftah M, Kommers D, Andriessen P, van Pul C, de Haan G. Multi-camera infrared thermography for infant respiration monitoring. BIOMEDICAL OPTICS EXPRESS 2020; 11:4848-4861. [PMID: 33014585 PMCID: PMC7510882 DOI: 10.1364/boe.397188] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/07/2020] [Revised: 07/21/2020] [Accepted: 07/28/2020] [Indexed: 05/08/2023]
Abstract
Respiration is monitored in neonatal wards using chest impedance (CI), which is obtrusive and can cause skin damage to the infants. Therefore, unobtrusive solutions based on infrared thermography are being investigated. This work proposes an algorithm to merge multiple thermal camera views and automatically detect the pixels containing respiration motion or flow using three features. The method was tested on 152 minutes of recordings acquired on seven infants. We performed a comparison with the CI respiration rate yielding a mean absolute error equal to 2.07 breaths/min. Merging the three features resulted in reducing the dependency on the window size typical of spectrum-based features.
Collapse
Affiliation(s)
- Ilde Lorato
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Sander Stuijk
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Mohammed Meftah
- Department of Family Care Solutions, Philips Research, Eindhoven, The Netherlands
| | - Deedee Kommers
- Department of Neonatology, Maxima Medical Centre, Veldhoven, The Netherlands
- Department of Applied Physics, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Peter Andriessen
- Department of Neonatology, Maxima Medical Centre, Veldhoven, The Netherlands
- Department of Applied Physics, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Carola van Pul
- Department of Applied Physics, Eindhoven University of Technology, Eindhoven, The Netherlands
- Department of Clinical Physics, Maxima Medical Centre, Veldhoven, The Netherlands
| | - Gerard de Haan
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| |
Collapse
|