1
|
Zhang Y, Yang J, Wan W, Zhao Q, Di M, Zhang D, Liu G, Chen C, Sun X, Zhang W, Bian H, Liu Y, Tian Y, Xue L, Dou Y, Wang Z, Li Q, Yang Q. Evaluation of biological performance of 3D printed trabecular porous tantalum spine fusion cage in large animal models. J Orthop Translat 2025; 50:185-195. [PMID: 39895865 PMCID: PMC11786794 DOI: 10.1016/j.jot.2024.10.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/11/2024] [Revised: 10/21/2024] [Accepted: 10/29/2024] [Indexed: 02/04/2025] Open
Abstract
Background The materials for artificial bone scaffolds have long been a focal point in biomaterials research. Tantalum, with its excellent bioactivity and tissue compatibility, has gradually become a promising alternative material. 3D printing technology shows unique advantages in designing complex structures, reducing costs, and providing personalized customization in the manufacture of porous tantalum fusion cages. Here we report the pre-clinical large animal (sheep) study on the newly developed 3D printed biomimetic trabecular porous tantalum fusion cage for assessing the long-term intervertebral fusion efficacy and safety. Methods Porous tantalum fusion cages were fabricated using laser powder bed fusion (LPBF) and chemical vapor deposition (CVD) methods. The fusion cages were characterized using scanning electron microscopy (SEM) and mechanical compression tests. Small-Tailed Han sheep served as the animal model, and the two types of fusion cages were implanted in the C3/4 cervical segments and followed for up to 12 months. Imaging techniques, including X-ray, CT scans, and Micro CT, were used to observe the bone integration of the fusion cages. Hard tissue sections were used to assess osteogenic effects and bone integration. The range of motion (ROM) of the motion segments was evaluated using a biomechanical testing machine. Serum biochemical indicators and pathological analysis of major organs were conducted to assess biocompatibility. Results X-ray imaging showed that both the 3D-printed and chemical vapor deposition porous tantalum fusion cages maintained comparable average intervertebral disc heights. Due to the presence of metal artifacts, CT and Micro CT imaging could not effectively analyze bone integration. Histomorphology data indicated that both the 3D-printed and chemical vapor deposition porous tantalum fusion cages exhibited similar levels of bone contact and integration at 3, 6, and 12 months, with bone bridging observed at 12 months. Both groups of fusion cages demonstrated consistent mechanical stability across all time points. Serum biochemistry showed no abnormalities, and no significant pathological changes were observed in the heart, liver, spleen, lungs, and kidneys. Conclusion This study confirms that 3D-printed and chemical vapor deposition porous tantalum fusion cages exhibit comparable, excellent osteogenic effects and long-term biocompatibility. Additionally, 3D-printed porous tantalum fusion cages offer unique advantages in achieving complex structural designs, low-cost manufacturing, and personalized customization, providing robust scientific support for future clinical applications. The translational potential of this article The translational potential of this paper is to use 3D printed biomimetic trabecular porous tantalum spine fusion cage with bone trabecular structure and validating its feasibility in large animal models (sheep). This study provides a basis for further research into the clinical application of the 3D printed biomimetic trabecular porous tantalum spine fusion cage.
Collapse
Affiliation(s)
- Yiming Zhang
- Department of Spine Surgery, Tianjin Hospital, Tianjin University, Tianjin, China
- Clinical School of Orthopedics, Tianjin Medical University, Tianjin, China
| | - Jingzhou Yang
- Institute of Materials Research, Tsinghua Shenzhen International Graduate School, Tsinghua University, Guangdong, China
- Shenzhen Dazhou Medical Technology Co., Ltd., Guangdong, China
| | - Wentao Wan
- Department of Spine Surgery, Tianjin Hospital, Tianjin University, Tianjin, China
- Clinical School of Orthopedics, Tianjin Medical University, Tianjin, China
| | - Qingqian Zhao
- Department of Spine Surgery, Tianjin Hospital, Tianjin University, Tianjin, China
- Clinical School of Orthopedics, Tianjin Medical University, Tianjin, China
| | - Mingyuan Di
- Department of Spine Surgery, Tianjin Hospital, Tianjin University, Tianjin, China
- Clinical School of Orthopedics, Tianjin Medical University, Tianjin, China
| | - Dachen Zhang
- Shenzhen Dazhou Medical Technology Co., Ltd., Guangdong, China
| | - Gang Liu
- Department of Spine Surgery, Tianjin Hospital, Tianjin University, Tianjin, China
- Clinical School of Orthopedics, Tianjin Medical University, Tianjin, China
| | - Chao Chen
- Department of Spine Surgery, Tianjin Hospital, Tianjin University, Tianjin, China
| | - Xun Sun
- Department of Spine Surgery, Tianjin Hospital, Tianjin University, Tianjin, China
| | - Wei Zhang
- Department of Spine Surgery, The Third Hospital of Hebei Medical University, Hebei Medical University, Hebei, China
| | - Hanming Bian
- Department of Spine Surgery, Tianjin Hospital, Tianjin University, Tianjin, China
- Clinical School of Orthopedics, Tianjin Medical University, Tianjin, China
| | - Yang Liu
- Department of Spine Surgery, Tianjin Hospital, Tianjin University, Tianjin, China
| | - Ye Tian
- Department of Spine Surgery, Tianjin Hospital, Tianjin University, Tianjin, China
| | - Lu Xue
- Department of Spine Surgery, Tianjin Hospital, Tianjin University, Tianjin, China
- Clinical School of Orthopedics, Tianjin Medical University, Tianjin, China
| | - Yiming Dou
- Department of Spine Surgery, Tianjin Hospital, Tianjin University, Tianjin, China
| | - Zheng Wang
- Department of Orthopedics, No.1 Medical Center of Chinese PLA General Hospital, Beijing, China
| | - Qiulin Li
- Institute of Materials Research, Tsinghua Shenzhen International Graduate School, Tsinghua University, Guangdong, China
| | - Qiang Yang
- Department of Spine Surgery, Tianjin Hospital, Tianjin University, Tianjin, China
- Clinical School of Orthopedics, Tianjin Medical University, Tianjin, China
| |
Collapse
|
2
|
Sun J, Liu SS, Zou D, Ni RH, Wei CB, Wang H, Li WS. A novel porous interbody fusion cage modified by microarc oxidation and hydrothermal treatment technology accelerate osseointegration and spinal fusion in sheep. RSC Adv 2024; 14:31966-31978. [PMID: 39391624 PMCID: PMC11462409 DOI: 10.1039/d3ra08185k] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2023] [Accepted: 08/25/2024] [Indexed: 10/12/2024] Open
Abstract
The clinical outcome of spinal fusion surgery is closely related to the success of bone fusion. Nowadays, the interbody cage which is used to replace the disc for spinal fusion is expected to have biological activity to improve osseointegration, especially for the aging and osteoporotic patients. Here, through micro-arc oxidation and hydrothermal treatment (MAO + HT), a bioactive CaP coating with micro/nano multilevel morphology was developed on 3D printed Ti6Al4V alloy then verified in vitro and in sheep anterior cervical decompression fusion model systematically. In vitro studies have confirmed the positive effects of characteristic micro/nano morphology and hydrophilicity of the coating formed after surface treatment on the adhesion, proliferation, and osteogenic differentiation of osteoblast precursor cells. Furthermore, the MAO + HT treated interbody cage showed a closer integration with the surrounding bone tissue, improved kinetic stability of the implanted segment, and significantly reduced incidence of fusion failure during the early postoperative period, which indicated that such a surface modification strategy is applicable to the biomechanical and biological microenvironment of the intervertebral space.
Collapse
Affiliation(s)
- Jiang Sun
- Peking University Third Hospital Beijing 100191 China
- Engineering Research Center of Bone and Joint Precision Medicine Department of Orthopedics Beijing 100191 China
- Beijing Key Laboratory of Spinal Disease Research Beijing 100191 China
| | - Shan-Shan Liu
- Peking University Third Hospital Beijing 100191 China
- Engineering Research Center of Bone and Joint Precision Medicine Department of Orthopedics Beijing 100191 China
- Beijing Key Laboratory of Spinal Disease Research Beijing 100191 China
| | - Da Zou
- Peking University Third Hospital Beijing 100191 China
- Engineering Research Center of Bone and Joint Precision Medicine Department of Orthopedics Beijing 100191 China
- Beijing Key Laboratory of Spinal Disease Research Beijing 100191 China
| | - Ren-Hua Ni
- Peking University Third Hospital Beijing 100191 China
- Engineering Research Center of Bone and Joint Precision Medicine Department of Orthopedics Beijing 100191 China
- Beijing Key Laboratory of Spinal Disease Research Beijing 100191 China
| | | | - Hao Wang
- Beijing AKec Medical Co., Ltd Beijing 102200 China
| | - Wei-Shi Li
- Peking University Third Hospital Beijing 100191 China
- Engineering Research Center of Bone and Joint Precision Medicine Department of Orthopedics Beijing 100191 China
- Beijing Key Laboratory of Spinal Disease Research Beijing 100191 China
| |
Collapse
|
3
|
The Effect of Ti-6Al-4V Alloy Surface Structure on the Adhesion and Morphology of Unidirectional Freeze-Coated Gelatin. COATINGS 2020. [DOI: 10.3390/coatings10050434] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
The modification of a metal implant surface with a biomimetic coating of bone-like anisotropic and graded porosity structures to improve its biological anchorage with the surrounding bone tissue at implanting, is still a high challenge. In this paper, we present an innovative way of a gelatin (GEL) dip-coating on Ti-6Al-4V substrates of different square-net surface textures by the unidirectional deep-freezing process at simultaneous cross-linking using carbodiimide chemistry. Different concentrations of GEL solution were used to study the changes in morphology, density, and mechanical properties of the coatings. In addition, the surface free energy and polarity of Ti-6Al-4V substrate surfaces and GEL solutions have been evaluated to assess the wetting properties at the substrate interfaces, and to describe the adhesion of GEL macromolecules with their surfaces, being supported by mechanical pull-out testing. The results indicate that the coating’s morphology depends primarily on the Ti-6Al-4V substrate’s surface texture and second, on the concentration of GEL, which further influences their adhesion properties, orientation, morphological arrangement, as well as compression strength. The substrate with a 300 × 300 μm2 texture resulted in a highly adhered GEL coating with ≥80% porosity, interconnected and well-aligned pores of 75–200 μm, required to stimulate the bone ingrowth, mechanically and histologically.
Collapse
|
5
|
Mazigi O, Kannan MB, Xu J, Choe HC, Ye Q. Biocompatibility and Degradation of a Low Elastic Modulus Ti-35Nb-3Zr Alloy: Nanosurface Engineering for Enhanced Degradation Resistance. ACS Biomater Sci Eng 2017; 3:509-517. [PMID: 33429618 DOI: 10.1021/acsbiomaterials.6b00563] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
In this study, the biocompatibility and degradation behavior of a low elastic modulus Ti-35Nb-3Zr alloy were investigated and compared with that of the conventional orthopedic and dental implant materials, i.e., commercially pure titanium (Cp-Ti) and Ti-6Al-4V alloy. The biocompatibility test results suggested that cells proliferate equally well on Ti-35Nb-3Zr and Cp-Ti. The degradation rates of Cp-Ti and Ti-6Al-4V were ∼68% (p < 0.05) and ∼84% (p < 0.05) lower as compared to Ti-35Nb-3Zr, respectively. Interestingly, the passive current density (ipass (1000mv)) of the Ti-35Nb-3Zr alloy was ∼29% lower than that of Cp-Ti, which suggests that the alloying elements in the Ti-35Nb-3Zr alloy have contributed to its passivation behavior. Nanosurface engineering of the Ti-35Nb-3Zr alloy, i.e., a two-step electrochemical process involving anodization (producing nanoporous layer) and calcium phosphate (CaP) deposition, decreased the degradation rate of the alloy by ∼83% (p < 0.05), and notably, it was similar to the conventional Ti-6Al-4V alloy. Hence, it can be suggested that the nanosurface-engineered low elastic modulus Ti-35Nb-3Zr alloy is a promising material for orthopedic and dental implant applications.
Collapse
Affiliation(s)
- Ohan Mazigi
- Biomaterials and Engineering Materials (BEM) Laboratory College of Science and Engineering, James Cook University, 1 James Cook Drive, Townsville, Queensland 4811, Australia
| | - M Bobby Kannan
- Biomaterials and Engineering Materials (BEM) Laboratory College of Science and Engineering, James Cook University, 1 James Cook Drive, Townsville, Queensland 4811, Australia
| | - Jia Xu
- College of Medicine and Dentistry, James Cook University, 14-88 McGregor Road, Cairns, Queensland 4878, Australia
| | - Han-Cheol Choe
- Department of Dental Materials, Chosun University, 375 Seosuk-dong, Dong-gu, Gwangju 501-759, South Korea
| | - Qingsong Ye
- School of Dentistry, The University of Queensland, 288 Herston Road, Brisbane, Queensland 4006, Australia
| |
Collapse
|
6
|
Voicu G, Miu D, Dogaru I, Jinga SI, Busuioc C. Vitroceramic interface deposited on titanium substrate by pulsed laser deposition method. Int J Pharm 2016; 510:449-56. [PMID: 26546909 DOI: 10.1016/j.ijpharm.2015.10.083] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2015] [Revised: 10/30/2015] [Accepted: 10/31/2015] [Indexed: 12/22/2022]
Abstract
Pulsed laser deposition (PLD) method was used to obtain biovitroceramic thin film coatings on titanium substrates. The composition of the targets was selected from SiO2-CaO-P2O5-(CaF2) systems and the corresponding masses were prepared using the sol-gel method. The depositions were performed in oxygen atmosphere (100mTorr), while the substrates were heated at 400°C. The PLD deposited films were analysed through different experimental techniques: X-ray diffraction, scanning (SEM, EDX) and transmission (HRTEM, SAED) electron microscopy and infra-red spectroscopy coupled with optical microscopy. They were also biologically tested by in vitro cell culture and the contact angle was determined. The bioevaluation results indicate a high biocompatibilty of the obtained materials, demonstrating their potential use for biomedical applications.
Collapse
Affiliation(s)
- Georgeta Voicu
- University POLITEHNICA of Bucharest, RO-011061 Bucharest, Romania
| | - Dana Miu
- National Institute for Laser, Plasma and Radiation Physics, RO-077125 Magurele, Romania
| | - Ionut Dogaru
- University POLITEHNICA of Bucharest, RO-011061 Bucharest, Romania
| | - Sorin Ion Jinga
- University POLITEHNICA of Bucharest, RO-011061 Bucharest, Romania
| | - Cristina Busuioc
- University POLITEHNICA of Bucharest, RO-011061 Bucharest, Romania.
| |
Collapse
|
8
|
Popa AC, Stan GE, Enculescu M, Tanase C, Tulyaganov DU, Ferreira JMF. Superior biofunctionality of dental implant fixtures uniformly coated with durable bioglass films by magnetron sputtering. J Mech Behav Biomed Mater 2015; 51:313-27. [PMID: 26282074 DOI: 10.1016/j.jmbbm.2015.07.028] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2015] [Revised: 07/26/2015] [Accepted: 07/27/2015] [Indexed: 12/11/2022]
Abstract
Bioactive glasses are currently considered the suitable candidates to stir the quest for a new generation of osseous implants with superior biological/functional performance. In congruence with this vision, this contribution aims to introduce a reliable technological recipe for coating fairly complex 3D-shaped implants (e.g. dental screws) with uniform and mechanical resistant bioactive glass films by the radio-frequency magnetron sputtering method. The mechanical reliability of the bioactive glass films applied to real Ti dental implant fixtures has been evaluated by a procedure comprised of "cold" implantation in pig mandibular bone from a dead animal, followed by immediate tension-free extraction tests. The effects of the complex mechanical strains occurring during implantation were analysed by scanning electron microscopy coupled with electron dispersive spectroscopy. Extensive biocompatibility assays (MTS, immunofluorescence, Western blot) revealed that the bioactive glass films stimulated strong cellular adhesion and proliferation of human dental pulp stem cells, without promoting their differentiation. The ability of the implant coatings to conserve a healthy stem cell pool is promising to further endorse the fabrication of new osseointegration implant designs with extended lifetime.
Collapse
Affiliation(s)
- A C Popa
- Army Centre for Medical Research, Bucharest 020012, Romania
| | - G E Stan
- National Institute of Materials Physics, Magurele-Ilfov 077125, Romania.
| | - M Enculescu
- National Institute of Materials Physics, Magurele-Ilfov 077125, Romania
| | - C Tanase
- "Victor Babes" National Institute of Pathology, Bucharest 050096, Romania
| | - D U Tulyaganov
- Turin Polytechnic University in Tashkent, Tashkent 100174, Uzbekistan
| | - J M F Ferreira
- Department of Materials and Ceramics Engineering, CICECO, University of Aveiro, Aveiro 3810-193, Portugal.
| |
Collapse
|