• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4604948)   Today's Articles (2095)   Subscriber (49371)
For: Kumsa DW, Bhadra N, Hudak EM, Mortimer JT. Electron transfer processes occurring on platinum neural stimulating electrodes: pulsing experiments for cathodic-first, charge-balanced, biphasic pulses for 0.566  ⩽  k  ⩽  2.3 in rat subcutaneous tissues. J Neural Eng 2017;14:056003. [PMID: 28813367 DOI: 10.1088/1741-2552/aa7a4a] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Number Cited by Other Article(s)
1
Shoffstall AJ, Capadona JR. Bioelectronic Neural Implants. Biomater Sci 2020. [DOI: 10.1016/b978-0-12-816137-1.00073-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
2
Sikder KU, Shivdasani MN, Fallon JB, Seligman P, Ganesan K, Villalobos J, Prawer S, Garrett DJ. Electrically conducting diamond films grown on platinum foil for neural stimulation. J Neural Eng 2019;16:066002. [DOI: 10.1088/1741-2552/ab2e79] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
3
Kumsa DW, Hudak EM, Bhadra N, Mortimer JT. Electron transfer processes occurring on platinum neural stimulating electrodes: pulsing experiments for cathodic-first, charge-imbalanced, biphasic pulses for 0.566  ⩽  k  ⩽  2.3 in rat subcutaneous tissues. J Neural Eng 2018;16:026018. [PMID: 30560809 DOI: 10.1088/1741-2552/aaf931] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
4
Harris AR, Newbold C, Carter P, Cowan R, Wallace GG. Measuring the effective area and charge density of platinum electrodes for bionic devices. J Neural Eng 2018;15:046015. [DOI: 10.1088/1741-2552/aaba8b] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
5
Cogan SF, Hara S, Ludwig KA. The Safe Delivery of Electrical Currents and Neuromodulation. Neuromodulation 2018. [DOI: 10.1016/b978-0-12-805353-9.00007-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA