1
|
Dallmer-Zerbe I, Jajcay N, Chvojka J, Janca R, Jezdik P, Krsek P, Marusic P, Jiruska P, Hlinka J. Computational modeling allows unsupervised classification of epileptic brain states across species. Sci Rep 2023; 13:13436. [PMID: 37596382 PMCID: PMC10439162 DOI: 10.1038/s41598-023-39867-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2023] [Accepted: 08/01/2023] [Indexed: 08/20/2023] Open
Abstract
Current advances in epilepsy treatment aim to personalize and responsively adjust treatment parameters to overcome patient heterogeneity in treatment efficiency. For tailoring treatment to the individual and the current brain state, tools are required that help to identify the patient- and time-point-specific parameters of epilepsy. Computational modeling has long proven its utility in gaining mechanistic insight. Recently, the technique has been introduced as a diagnostic tool to predict individual treatment outcomes. In this article, the Wendling model, an established computational model of epilepsy dynamics, is used to automatically classify epileptic brain states in intracranial EEG from patients (n = 4) and local field potential recordings from in vitro rat data (high-potassium model of epilepsy, n = 3). Five-second signal segments are classified to four types of brain state in epilepsy (interictal, preonset, onset, ictal) by comparing a vector of signal features for each data segment to four prototypical feature vectors obtained by Wendling model simulations. The classification result is validated against expert visual assessment. Model-driven brain state classification achieved a classification performance significantly above chance level (mean sensitivity 0.99 on model data, 0.77 on rat data, 0.56 on human data in a four-way classification task). Model-driven prototypes showed similarity with data-driven prototypes, which we obtained from real data for rats and humans. Our results indicate similar electrophysiological patterns of epileptic states in the human brain and the animal model that are well-reproduced by the computational model, and captured by a key set of signal features, enabling fully automated and unsupervised brain state classification in epilepsy.
Collapse
Affiliation(s)
- Isa Dallmer-Zerbe
- Department of Complex Systems, Institute of Computer Science, Czech Academy of Sciences, 182 00, Prague, Czech Republic
- Department of Physiology, Second Faculty of Medicine, Charles University, 150 06, Prague, Czech Republic
| | - Nikola Jajcay
- Department of Complex Systems, Institute of Computer Science, Czech Academy of Sciences, 182 00, Prague, Czech Republic
- National Institute of Mental Health, 250 67, Klecany, Czech Republic
| | - Jan Chvojka
- Department of Physiology, Second Faculty of Medicine, Charles University, 150 06, Prague, Czech Republic
- Department of Circuit Theory, Faculty of Electrical Engineering, Czech Technical University in Prague, 166 27, Prague, Czech Republic
| | - Radek Janca
- Department of Circuit Theory, Faculty of Electrical Engineering, Czech Technical University in Prague, 166 27, Prague, Czech Republic
| | - Petr Jezdik
- Department of Circuit Theory, Faculty of Electrical Engineering, Czech Technical University in Prague, 166 27, Prague, Czech Republic
| | - Pavel Krsek
- Department of Paediatric Neurology, Second Faculty of Medicine, Motol University Hospital, Charles University, 150 06, Prague, Czech Republic
| | - Petr Marusic
- Department of Neurology, Second Faculty of Medicine, Motol University Hospital, Charles University, 150 06, Prague, Czech Republic
| | - Premysl Jiruska
- Department of Physiology, Second Faculty of Medicine, Charles University, 150 06, Prague, Czech Republic
| | - Jaroslav Hlinka
- Department of Complex Systems, Institute of Computer Science, Czech Academy of Sciences, 182 00, Prague, Czech Republic.
- National Institute of Mental Health, 250 67, Klecany, Czech Republic.
| |
Collapse
|
2
|
Cui D, Li H, Liu P, Gu G, Li X, Wang L, Yin S. Analysis of the neural mechanism of spectra decrease in MCI by a thalamo-cortical coupled neural mass model. J Neural Eng 2022; 19. [PMID: 36536986 DOI: 10.1088/1741-2552/aca82b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2022] [Accepted: 12/01/2022] [Indexed: 12/04/2022]
Abstract
Objective.In order to deeply understand the neurophysiological mechanism of the spectra decrease in mild cognitive impairment (MCI), this paper studies a new neural mass model, which can simulate various intracerebral electrophysiological activities.Approach. In this study, a thalamo-cortical coupled neural mass model (TCC-NMM) is proposed. The influences of the coupling coefficients and other key parameters on the model spectra are simulated. Then, the unscented Kalman filter (UKF) algorithm is used to reversely identify the parameters in the TCC-NMM. Furthermore, the TCC-NMM and UKF are combined to analyze the spectra reduction mechanism of electroencephalogram (EEG) signals in MCI patients. The independent sample t-test is carried out to statistical analyze the differences of the identified parameters between MCI and normal controls. The Pearson correlation analysis is used to analyze the intrinsic relationship between parameters and the scores of the comprehensive competence assessment scale.Main results.The simulation results show that the decreased cortical synaptic connectivity constantsC1can result in spectra decrease of the TCC-NMM outputs. The real EEG analysis results show that the identified values of parameterC1are significant lower in the MCI group than in control group in frontal and occipital areas and the parametersC1are positively correlated with the Montreal Cognitive Assessment (MoCA) scores in the two areas. This consistency suggests that the cortical synaptic connectivity loss from pyramidal cells to excitatory interneurons (eIN) may be one of the neural mechanisms of EEG spectra decrease in MCI.Significance. (a) In this study, a new mathematical model TCCNMM based on anatomy and neurophysiology is proposed. (b) All key parameters in TCC-NMM are studied in detail through the forward and reverse analysis and the influence of these parameters on the output spectra of the model is pointed out. (c) The possible neural mechanism of the decreased spectra in MCI patients is pointed out by the joint analysis of simulation in forward with TCC-NMM and analysis of the actual EEG signals in reverse with UKF identification algorithm. (d) We find that the identified parameter C1 of MCI patients is significantly lower than that of the control group, which is consistent with the simulation analysis of TCC-NMM. So, we suggest that the decreased MCI alpha power spectrum is likely related to the cortical synaptic connection loss from pyramidal cells to eIN.
Collapse
Affiliation(s)
- Dong Cui
- Hebei Key Laboratory of Information Transmission and Signal Processing, School of Information Science and Engineering, Yanshan University, Qinhuangdao 066004, People's Republic of China
| | - Han Li
- Hebei Key Laboratory of Information Transmission and Signal Processing, School of Information Science and Engineering, Yanshan University, Qinhuangdao 066004, People's Republic of China
| | - Pengxiang Liu
- Hebei Key Laboratory of Information Transmission and Signal Processing, School of Information Science and Engineering, Yanshan University, Qinhuangdao 066004, People's Republic of China
| | - Guanghua Gu
- Hebei Key Laboratory of Information Transmission and Signal Processing, School of Information Science and Engineering, Yanshan University, Qinhuangdao 066004, People's Republic of China
| | - Xiaoli Li
- National Key Laboratory of Cognitive Neuroscience and Learning, Beijing Normal University, Beijing 100875, People's Republic of China
| | - Lei Wang
- Department of Neurology, PLA Rocket Force Characteristic Medical Center, Beijing 100088, People's Republic of China
| | - Shimin Yin
- Department of Neurology, PLA Rocket Force Characteristic Medical Center, Beijing 100088, People's Republic of China
| |
Collapse
|
3
|
Phogat R, Parmananda P, Prasad A. Intensity dependence of sub-harmonics in cortical response to photic stimulation. J Neural Eng 2022; 19. [PMID: 35839731 DOI: 10.1088/1741-2552/ac817f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2022] [Accepted: 07/15/2022] [Indexed: 11/11/2022]
Abstract
Objective. Periodic photic stimulation of human volunteers at 10 Hz is known to entrain their Electroencephalography (EEG) signals. This entrainment manifests as an increment in power at 10, 20, 30 Hz. We observed that this entrainment is accompanied by the emergence of sub-harmonics, but only at specific frequencies and higher intensities of the stimulating signal. Thereafter, we describe our results and explain them using the physiologically inspired Jansen and Rit Neural Mass Model (NMM).Approach. Four human volunteers were separately exposed to both high and low intensity 10 Hz and 6 Hz stimulation. A total of 4 experiments per subject were therefore performed. Simulations and bifurcation analysis of the NMM were carried out and compared with the experimental findings. <i> Main results. High intensity 10 Hz stimulation led to an increment in power at 5 Hz across all the 4 subjects. No increment of power was observed with low intensity stimulation. However, when the same protocol was repeated with a 6 Hz photic stimulation, neither high nor low intensity stimulation were found to cause a discernible change in power at 3 Hz. We found that the NMM was able to recapitulate these results. A further numerical analysis indicated that this arises from the underlying bifurcation structure of the NMM. <i> Significance. The excellent match between theory and experiment suggest that the bifurcation properties of the NMM are mirroring similar features possessed by the actual neural masses producing the EEG dynamics. Neural Mass Models could thus be valuable for understanding properties and pathologies of EEG dynamics, and may contribute to the engineering of brain-computer interface technologies.
Collapse
Affiliation(s)
- Richa Phogat
- Indian Institute of Technology Bombay, Department of Physics, Indian Institute of Technology - Bombay, Mumbai, 400076, INDIA
| | - P Parmananda
- Indian Institute of Technology Bombay, Department of Physics, Indian Institute of Technology - Bombay, Mumbai, Maharashtra, 400076, INDIA
| | - Ashok Prasad
- Colorado State University, Department of Chemical and Biological Engineering and School of Biomedical Engineering, Colorado State University, Fort Collins, Colorado, 80523-1019, UNITED STATES
| |
Collapse
|
4
|
Shariat A, Zarei A, Karvigh SA, Asl BM. Automatic detection of epileptic seizures using Riemannian geometry from scalp EEG recordings. Med Biol Eng Comput 2021; 59:1431-1445. [PMID: 34128177 DOI: 10.1007/s11517-021-02385-z] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2020] [Accepted: 05/15/2021] [Indexed: 11/30/2022]
Abstract
This paper proposes a new framework for epileptic seizure detection using non-invasive scalp electroencephalogram (sEEG) signals. The major innovation of the current study is using the Riemannian geometry for transforming the covariance matrices estimated from the EEG channels into a feature vector. The spatial covariance matrices are considered as features in order to extract the spatial information of the sEEG signals without applying any spatial filtering. Since these matrices are symmetric and positive definite (SPD), they belong to a special manifold called the Riemannian manifold. Furthermore, a kernel based on Riemannian geometry is proposed. This kernel maps the SPD matrices onto the Riemannian tangent space. The SPD matrices, obtained from all channels of the segmented sEEG signals, have high dimensions and extra information. For these reasons, the sequential forward feature selection method is applied to select the best features and reduce the computational burden in the classification step. The selected features are fed into a support vector machine (SVM) with an RBF kernel to classify the feature vectors into seizure and non-seizure classes. The performance of the proposed method is evaluated using two long-term scalp EEG (CHB-MIT benchmark and private) databases. Experimental results on all 23 subjects of the CHB-MIT database reveal an accuracy of 99.87%, a sensitivity of 99.91%, and a specificity of 99.82%. In addition, the introduced algorithm is tested on the private sEEG signals recorded from 20 patients, having 1380 seizures. The proposed approach achieves an accuracy, a sensitivity, and a specificity of 98.14%, 98.16%, and 98.12%, respectively. The experimental results on both sEEG databases demonstrate the effectiveness of the proposed method for automated epileptic seizure detection, especially for the private database which has noisier signals in comparison to the CHB-MIT database. Graphical Abstract Block diagram of the proposed epileptic seizure detection algorithm.
Collapse
Affiliation(s)
- Atefeh Shariat
- Department of Biomedical Engineering, Tarbiat Modares University, Tehran, Iran
| | - Asghar Zarei
- Department of Biomedical Engineering, Tarbiat Modares University, Tehran, Iran
| | - Sanaz Ahmadi Karvigh
- Department of Neurology, Sina Hospital, Tehran University of Medical Sciences, Tehran, Iran
| | | |
Collapse
|
5
|
Hamavar R, Asl BM. Seizure onset detection based on detection of changes in brain activity quantified by evolutionary game theory model. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2021; 199:105899. [PMID: 33360360 DOI: 10.1016/j.cmpb.2020.105899] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/07/2020] [Accepted: 12/01/2020] [Indexed: 06/12/2023]
Abstract
BACKGROUND AND OBJECTIVE Epilepsy is one of the most common diseases of the nervous system, affecting about 1% of the world's population. The unpredictable nature of the epilepsy seizures deprives the patients and those around them of living a normal life. Therefore, the development of new methods that can help these patients will increase the life quality of these people and can bring a lot of economic savings in the health sector. METHODS In this study, we introduced a new framework for seizure onset detection. Our framework provides a new modelling for brain activity using evolutionary game theory and Kalman filter. If the patterns in the electroencephalogram (EEG) signal violate the predicted patterns by the proposed model, using a novel detection algorithm that has been also introduced in this paper, it can be determined whether the observed violation is the result of the onset of an epileptic seizure or not. RESULTS The proposed approach was able to detect the onset of all the seizures in CHB-MIT dataset with an average delay of -0.8 s and a false alarm of 0.39 per hour. Also, our proposed approach is about 20 times faster compared to recent studies. CONCLUSIONS The experimental results of applying the proposed framework on the CHB-MIT dataset show that our framework not only performed well with respect to the sensitivity, delay, and false alarm metrics but also performed much better in terms of run time compared to recent studies. This appropriate run time, along with other suitable metrics, makes it possible to use this framework in many cases where processing power or energy is limited and to think about creating new and inexpensive solutions for the treatment and care of people diagnosed with epilepsy.
Collapse
Affiliation(s)
- Ramtin Hamavar
- Department of Electrical and Computer Engineering, Tarbiat Modares University, Tehran, Iran
| | - Babak Mohammadzadeh Asl
- Department of Electrical and Computer Engineering, Tarbiat Modares University, Tehran, Iran.
| |
Collapse
|