1
|
Ell M, Bui MT, Kigili S, Zeck G, Prado-López S. Assessment of chemotherapeutic effects on cancer cells using adhesion noise spectroscopy. Front Bioeng Biotechnol 2024; 12:1385730. [PMID: 38803844 PMCID: PMC11128629 DOI: 10.3389/fbioe.2024.1385730] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2024] [Accepted: 04/12/2024] [Indexed: 05/29/2024] Open
Abstract
With cancer as one of the leading causes of death worldwide, there is a need for the development of accurate, cost-effective, easy-to-use, and fast drug-testing assays. While the NCI 60 cell-line screening as the gold standard is based on a colorimetric assay, monitoring cells electrically constitutes a label-free and non-invasive tool to assess the cytotoxic effects of a chemotherapeutic treatment on cancer cells. For decades, impedance-based cellular assays extensively investigated various cell characteristics affected by drug treatment but lack spatiotemporal resolution. With progress in microelectrode fabrication, high-density Complementary Metal Oxide Semiconductor (CMOS)-based microelectrode arrays (MEAs) with subcellular resolution and time-continuous recording capability emerged as a potent alternative. In this article, we present a new cell adhesion noise (CAN)-based electrical imaging technique to expand CMOS MEA cell-biology applications: CAN spectroscopy enables drug screening quantification with single-cell spatial resolution. The chemotherapeutic agent 5-Fluorouracil exerts a cytotoxic effect on colorectal cancer (CRC) cells hampering cell proliferation and lowering cell viability. For proof-of-concept, we found sufficient accuracy and reproducibility for CAN spectroscopy compared to a commercially available standard colorimetric biological assay. This label-free, non-invasive, and fast electrical imaging technique complements standardized cancer screening methods with significant advances over established impedance-based approaches.
Collapse
Affiliation(s)
- Maximilian Ell
- Institute of Biomedical Electronics, Faculty of Electrical Engineering and Information Technology, TU Wien, Vienna, Austria
| | - Mai Thu Bui
- Institute of Biomedical Electronics, Faculty of Electrical Engineering and Information Technology, TU Wien, Vienna, Austria
| | - Seyda Kigili
- Institute of Solid State Electronics, Faculty of Electrical Engineering and Information Technology, TU Wien, Vienna, Austria
| | - Günther Zeck
- Institute of Biomedical Electronics, Faculty of Electrical Engineering and Information Technology, TU Wien, Vienna, Austria
| | - Sonia Prado-López
- Institute of Solid State Electronics, Faculty of Electrical Engineering and Information Technology, TU Wien, Vienna, Austria
| |
Collapse
|
2
|
Corna A, Cojocaru AE, Bui MT, Werginz P, Zeck G. Avoidance of axonal stimulation with sinusoidal epiretinal stimulation. J Neural Eng 2024; 21:026036. [PMID: 38547529 DOI: 10.1088/1741-2552/ad38de] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2023] [Accepted: 03/28/2024] [Indexed: 04/11/2024]
Abstract
Objective.Neuromodulation, particularly electrical stimulation, necessitates high spatial resolution to achieve artificial vision with high acuity. In epiretinal implants, this is hindered by the undesired activation of distal axons. Here, we investigate focal and axonal activation of retinal ganglion cells (RGCs) in epiretinal configuration for different sinusoidal stimulation frequencies.Approach.RGC responses to epiretinal sinusoidal stimulation at frequencies between 40 and 100 Hz were tested inex-vivophotoreceptor degenerated (rd10) isolated retinae. Experiments were conducted using a high-density CMOS-based microelectrode array, which allows to localize RGC cell bodies and axons at high spatial resolution.Main results.We report current and charge density thresholds for focal and distal axon activation at stimulation frequencies of 40, 60, 80, and 100 Hz for an electrode size with an effective area of 0.01 mm2. Activation of distal axons is avoided up to a stimulation amplitude of 0.23µA (corresponding to 17.3µC cm-2) at 40 Hz and up to a stimulation amplitude of 0.28µA (14.8µC cm-2) at 60 Hz. The threshold ratio between focal and axonal activation increases from 1.1 for 100 Hz up to 1.6 for 60 Hz, while at 40 Hz stimulation frequency, almost no axonal responses were detected in the tested intensity range. With the use of synaptic blockers, we demonstrate the underlying direct activation mechanism of the ganglion cells. Finally, using high-resolution electrical imaging and label-free electrophysiological axon tracking, we demonstrate the extent of activation in axon bundles.Significance.Our results can be exploited to define a spatially selective stimulation strategy avoiding axonal activation in future retinal implants, thereby solving one of the major limitations of artificial vision. The results may be extended to other fields of neuroprosthetics to achieve selective focal electrical stimulation.
Collapse
Affiliation(s)
- Andrea Corna
- Institute of Biomedical Electronics, TU Wien, Vienna, Austria
| | | | - Mai Thu Bui
- Institute of Biomedical Electronics, TU Wien, Vienna, Austria
| | - Paul Werginz
- Institute of Biomedical Electronics, TU Wien, Vienna, Austria
| | - Günther Zeck
- Institute of Biomedical Electronics, TU Wien, Vienna, Austria
| |
Collapse
|
3
|
Cojocaru AE, Corna A, Reh M, Zeck G. High spatial resolution artificial vision inferred from the spiking output of retinal ganglion cells stimulated by optogenetic and electrical means. Front Cell Neurosci 2022; 16:1033738. [PMID: 36568888 PMCID: PMC9780279 DOI: 10.3389/fncel.2022.1033738] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2022] [Accepted: 11/10/2022] [Indexed: 12/13/2022] Open
Abstract
With vision impairment affecting millions of people world-wide, various strategies aiming at vision restoration are being undertaken. Thanks to decades of extensive research, electrical stimulation approaches to vision restoration began to undergo clinical trials. Quite recently, another technique employing optogenetic therapy emerged as a possible alternative. Both artificial vision restoration strategies reported poor spatial resolution so far. In this article, we compared the spatial resolution inferred ex vivo under ideal conditions using a computational model analysis of the retinal ganglion cell (RGC) spiking activity. The RGC spiking was stimulated in epiretinal configuration by either optogenetic or electrical means. RGCs activity was recorded from the ex vivo retina of transgenic late-stage photoreceptor-degenerated mice (rd10) using a high-density Complementary Metal Oxide Semiconductor (CMOS) based microelectrode array. The majority of retinal samples were stimulated by both, optogenetic and electrical stimuli using a spatial grating stimulus. A population-level analysis of the spiking activity of identified RGCs was performed and the spatial resolution achieved through electrical and optogenetic photo-stimulation was inferred using a support vector machine classifier. The best f1 score of the classifier for the electrical stimulation in epiretinal configuration was 86% for 32 micron wide gratings and increased to 100% for 128 microns. For optogenetically activated cells, we obtained high f1 scores of 82% for 10 microns grid width for a photo-stimulation frequency of 2.5 Hz and 73% for a photo-stimulation frequency of 10 Hz. A subsequent analysis, considering only the RGCs modulated in both electrical and optogenetic stimulation protocols revealed no significant difference in the prediction accuracy between the two stimulation modalities. The results presented here indicate that a high spatial resolution can be achieved for electrical or optogenetic artificial stimulation using the activated retinal ganglion cell output.
Collapse
Affiliation(s)
| | - Andrea Corna
- Institute of Biomedical Electronics, TU Wien, Vienna, Austria
| | - Miriam Reh
- Institute for Ophthalmic Research at the University of Tübingen, Tübingen, Germany
| | - Günther Zeck
- Institute of Biomedical Electronics, TU Wien, Vienna, Austria
| |
Collapse
|
4
|
Carleton M, Oesch NW. Differences in the spatial fidelity of evoked and spontaneous signals in the degenerating retina. Front Cell Neurosci 2022; 16:1040090. [PMID: 36419935 PMCID: PMC9676928 DOI: 10.3389/fncel.2022.1040090] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2022] [Accepted: 10/20/2022] [Indexed: 07/01/2024] Open
Abstract
Vision restoration strategies aim to reestablish vision by replacing the function of lost photoreceptors with optoelectronic hardware or through gene therapy. One complication to these approaches is that retinal circuitry undergoes remodeling after photoreceptor loss. Circuit remodeling following perturbation is ubiquitous in the nervous system and understanding these changes is crucial for treating neurodegeneration. Spontaneous oscillations that arise during retinal degeneration have been well-studied, however, other changes in the spatiotemporal processing of evoked and spontaneous activity have received less attention. Here we use subretinal electrical stimulation to measure the spatial and temporal spread of both spontaneous and evoked activity during retinal degeneration. We found that electrical stimulation synchronizes spontaneous oscillatory activity, over space and through time, thus leading to increased correlations in ganglion cell activity. Intriguingly, we found that spatial selectivity was maintained in rd10 retina for evoked responses, with spatial receptive fields comparable to wt retina. These findings indicate that different biophysical mechanisms are involved in mediating feed forward excitation, and the lateral spread of spontaneous activity in the rd10 retina, lending support toward the possibility of high-resolution vision restoration.
Collapse
Affiliation(s)
- Maya Carleton
- Department of Psychology, University of California, San Diego, La Jolla, CA, United States
| | - Nicholas W. Oesch
- Department of Psychology, University of California, San Diego, La Jolla, CA, United States
- Department of Ophthalmology, University of California, San Diego, La Jolla, CA, United States
- The Neurosciences Graduate Program, University of California, San Diego, La Jolla, CA, United States
| |
Collapse
|
5
|
Eickenscheidt M, Herrmann T, Weisshap M, Mittnacht A, Rudmann L, Zeck G, Stieglitz T. An optoelectronic neural interface approach for precise superposition of optical and electrical stimulation in flexible array structures. Biosens Bioelectron 2022; 205:114090. [DOI: 10.1016/j.bios.2022.114090] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2021] [Revised: 02/07/2022] [Accepted: 02/09/2022] [Indexed: 11/27/2022]
|
6
|
Vilkhu RS, Madugula SS, Grosberg LE, Gogliettino AR, Hottowy P, Dabrowski W, Sher A, Litke AM, Mitra S, Chichilnisky EJ. Spatially patterned bi-electrode epiretinal stimulation for axon avoidance at cellular resolution. J Neural Eng 2021; 18. [PMID: 34710857 DOI: 10.1088/1741-2552/ac3450] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2021] [Accepted: 10/28/2021] [Indexed: 11/12/2022]
Abstract
Objective.Epiretinal prostheses are designed to restore vision to people blinded by photoreceptor degenerative diseases by stimulating surviving retinal ganglion cells (RGCs), which carry visual signals to the brain. However, inadvertent stimulation of RGCs at their axons can result in non-focal visual percepts, limiting the quality of artificial vision. Theoretical work has suggested that axon activation can be avoided with current stimulation designed to minimize the second spatial derivative of the induced extracellular voltage along the axon. However, this approach has not been verified experimentally at the resolution of single cells.Approach.In this work, a custom multi-electrode array (512 electrodes, 10μm diameter, 60μm pitch) was used to stimulate and record RGCs in macaque retinaex vivoat single-cell, single-spike resolution. RGC activation thresholds resulting from bi-electrode stimulation, which consisted of bipolar currents simultaneously delivered through two electrodes straddling an axon, were compared to activation thresholds from traditional single-electrode stimulation.Main results.On average, across three retinal preparations, the bi-electrode stimulation strategy reduced somatic activation thresholds (∼21%) while increasing axonal activation thresholds (∼14%), thus favoring selective somatic activation. Furthermore, individual examples revealed rescued selective activation of somas that was not possible with any individual electrode.Significance.This work suggests that a bi-electrode epiretinal stimulation strategy can reduce inadvertent axonal activation at cellular resolution, for high-fidelity artificial vision.
Collapse
Affiliation(s)
- Ramandeep S Vilkhu
- Department of Electrical Engineering, Stanford University, Stanford, CA, United States of America
| | - Sasidhar S Madugula
- Departments of Neurosurgery, Ophthalmology, and Hansen Experimental Physics Laboratory, Stanford University, Stanford, CA, United States of America
| | - Lauren E Grosberg
- Departments of Neurosurgery, Ophthalmology, and Hansen Experimental Physics Laboratory, Stanford University, Stanford, CA, United States of America
| | - Alex R Gogliettino
- Departments of Neurosurgery, Ophthalmology, and Hansen Experimental Physics Laboratory, Stanford University, Stanford, CA, United States of America
| | - Pawel Hottowy
- Faculty of Physics and Applied Computer Science, AGH University of Science and Technology, Krakow 30-059, Poland
| | - Wladyslaw Dabrowski
- Faculty of Physics and Applied Computer Science, AGH University of Science and Technology, Krakow 30-059, Poland
| | - Alexander Sher
- Santa Cruz Institute for Particle Physics, University of California, Santa Cruz, CA, United States of America
| | - Alan M Litke
- Santa Cruz Institute for Particle Physics, University of California, Santa Cruz, CA, United States of America
| | - Subhasish Mitra
- Department of Electrical Engineering, Stanford University, Stanford, CA, United States of America
| | - E J Chichilnisky
- Departments of Neurosurgery, Ophthalmology, and Hansen Experimental Physics Laboratory, Stanford University, Stanford, CA, United States of America
| |
Collapse
|
7
|
Corna A, Ramesh P, Jetter F, Lee MJ, Macke JH, Zeck G. Discrimination of simple objects decoded from the output of retinal ganglion cells upon sinusoidal electrical stimulation. J Neural Eng 2021; 18. [PMID: 34049288 DOI: 10.1088/1741-2552/ac0679] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2021] [Accepted: 05/28/2021] [Indexed: 11/12/2022]
Abstract
Objective. Most neuroprosthetic implants employ pulsatile square-wave electrical stimuli, which are significantly different from physiological inter-neuronal communication. In case of retinal neuroprosthetics, which use a certain type of pulsatile stimuli, reliable object and contrast discrimination by implanted blind patients remained challenging. Here we investigated to what extent simple objects can be discriminated from the output of retinal ganglion cells (RGCs) upon sinusoidal stimulation.Approach. Spatially confined objects were formed by different combinations of 1024 stimulating microelectrodes. The RGC activity in theex vivoretina of photoreceptor-degenerated mouse, of healthy mouse or of primate was recorded simultaneously using an interleaved recording microelectrode array implemented in a CMOS-based chip.Main results. We report that application of sinusoidal electrical stimuli (40 Hz) in epiretinal configuration instantaneously and reliably modulates the RGC activity in spatially confined areas at low stimulation threshold charge densities (40 nC mm-2). Classification of overlapping but spatially displaced objects (1° separation) was achieved by distinct spiking activity of selected RGCs. A classifier (regularized logistic regression) discriminated spatially displaced objects (size: 5.5° or 3.5°) with high accuracy (90% or 62%). Stimulation with low artificial contrast (10%) encoded by different stimulus amplitudes generated RGC activity, which was classified with an accuracy of 80% for large objects (5.5°).Significance. We conclude that time-continuous smooth-wave stimulation provides robust, localized neuronal activation in photoreceptor-degenerated retina, which may enable future artificial vision at high temporal, spatial and contrast resolution.
Collapse
Affiliation(s)
- Andrea Corna
- Neurophysics, NMI Natural and Medical Sciences Institute at the University Tübingen, Reutlingen, Germany.,Institute for Ophthalmic Research, University of Tübingen, Tübingen, Germany.,Graduate School of Neural Information Processing/International Max Planck Research School, Tübingen, Germany.,Biomedical Electronics and Systems, EMCE Institute, TU Wien, Wien, Austria
| | - Poornima Ramesh
- Computational Neuroengineering, Technical University München, München, Germany.,Machine Learning in Science, University of Tübingen, Tübingen, Germany
| | - Florian Jetter
- Neurophysics, NMI Natural and Medical Sciences Institute at the University Tübingen, Reutlingen, Germany.,Graduate School of Neural Information Processing/International Max Planck Research School, Tübingen, Germany
| | - Meng-Jung Lee
- Neurophysics, NMI Natural and Medical Sciences Institute at the University Tübingen, Reutlingen, Germany.,Graduate School of Neural Information Processing/International Max Planck Research School, Tübingen, Germany
| | - Jakob H Macke
- Computational Neuroengineering, Technical University München, München, Germany.,Machine Learning in Science, University of Tübingen, Tübingen, Germany.,MPI for Intelligent Systems, Tübingen, Germany
| | - Günther Zeck
- Neurophysics, NMI Natural and Medical Sciences Institute at the University Tübingen, Reutlingen, Germany.,Biomedical Electronics and Systems, EMCE Institute, TU Wien, Wien, Austria
| |
Collapse
|
8
|
Oesterle J, Behrens C, Schröder C, Hermann T, Euler T, Franke K, Smith RG, Zeck G, Berens P. Bayesian inference for biophysical neuron models enables stimulus optimization for retinal neuroprosthetics. eLife 2020; 9:e54997. [PMID: 33107821 PMCID: PMC7673784 DOI: 10.7554/elife.54997] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2020] [Accepted: 10/26/2020] [Indexed: 01/02/2023] Open
Abstract
While multicompartment models have long been used to study the biophysics of neurons, it is still challenging to infer the parameters of such models from data including uncertainty estimates. Here, we performed Bayesian inference for the parameters of detailed neuron models of a photoreceptor and an OFF- and an ON-cone bipolar cell from the mouse retina based on two-photon imaging data. We obtained multivariate posterior distributions specifying plausible parameter ranges consistent with the data and allowing to identify parameters poorly constrained by the data. To demonstrate the potential of such mechanistic data-driven neuron models, we created a simulation environment for external electrical stimulation of the retina and optimized stimulus waveforms to target OFF- and ON-cone bipolar cells, a current major problem of retinal neuroprosthetics.
Collapse
Affiliation(s)
- Jonathan Oesterle
- Institute for Ophthalmic Research, University of TübingenTübingenGermany
| | - Christian Behrens
- Institute for Ophthalmic Research, University of TübingenTübingenGermany
| | - Cornelius Schröder
- Institute for Ophthalmic Research, University of TübingenTübingenGermany
| | - Thoralf Hermann
- Naturwissenschaftliches und Medizinisches Institut an der Universität TübingenReutlingenGermany
| | - Thomas Euler
- Institute for Ophthalmic Research, University of TübingenTübingenGermany
- Center for Integrative Neuroscience, University of TübingenTübingenGermany
- Bernstein Center for Computational Neuroscience, University of TübingenTübingenGermany
| | - Katrin Franke
- Institute for Ophthalmic Research, University of TübingenTübingenGermany
- Bernstein Center for Computational Neuroscience, University of TübingenTübingenGermany
| | - Robert G Smith
- Department of Neuroscience, University of PennsylvaniaPhiladelphiaUnited States
| | - Günther Zeck
- Naturwissenschaftliches und Medizinisches Institut an der Universität TübingenReutlingenGermany
| | - Philipp Berens
- Institute for Ophthalmic Research, University of TübingenTübingenGermany
- Center for Integrative Neuroscience, University of TübingenTübingenGermany
- Bernstein Center for Computational Neuroscience, University of TübingenTübingenGermany
- Institute for Bioinformatics and Medical Informatics, University of TübingenTübingenGermany
| |
Collapse
|
9
|
Srivastava SB, Melikov R, Yildiz E, Han M, Sahin A, Nizamoglu S. Efficient photocapacitors via ternary hybrid photovoltaic optimization for photostimulation of neurons. BIOMEDICAL OPTICS EXPRESS 2020; 11:5237-5248. [PMID: 33014611 PMCID: PMC7510852 DOI: 10.1364/boe.396068] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/24/2020] [Revised: 07/16/2020] [Accepted: 08/03/2020] [Indexed: 05/31/2023]
Abstract
Optoelectronic photoelectrodes based on capacitive charge-transfer offer an attractive route to develop safe and effective neuromodulators. Here, we demonstrate efficient optoelectronic photoelectrodes that are based on the incorporation of quantum dots (QDs) into poly(3-hexylthiophene-2,5-diyl) (P3HT) and [6,6]-Phenyl-C61-butyric acid methyl ester (PCBM) bulk heterojunction. We control the performance of the photoelectrode by the blend ratio, thickness, and nanomorphology of the ternary bulk heterojunction. The optimization led to a photocapacitor that has a photovoltage of 450 mV under a light intensity level of 20 mW.cm-2 and a responsivity of 99 mA/W corresponding to the most light-sensitive organic photoelectrode reported to date. The photocapacitor can facilitate action potential generation by hippocampal neurons via burst waveforms at an intensity level of 20 mW.cm-2. Therefore, the results point to an alternative direction in the engineering of safe and ultra-light-sensitive neural interfaces.
Collapse
Affiliation(s)
| | - Rustamzhon Melikov
- Department of Electrical and Electronics Engineering, Koc University, Istanbul 34450, Turkey
| | - Erdost Yildiz
- Koc University Research Center for Translational Medicine, Koc University, Istanbul 34450, Turkey
| | - Mertcan Han
- Department of Electrical and Electronics Engineering, Koc University, Istanbul 34450, Turkey
| | - Afsun Sahin
- Koc University Research Center for Translational Medicine, Koc University, Istanbul 34450, Turkey
- Department of Ophthalmology, Medical School, Koc University, Istanbul 34450, Turkey
| | - Sedat Nizamoglu
- Department of Electrical and Electronics Engineering, Koc University, Istanbul 34450, Turkey
- Graduate School of Biomedical Sciences and Engineering, Koc University, Istanbul 34450, Turkey
| |
Collapse
|
10
|
Tong W, Meffin H, Garrett DJ, Ibbotson MR. Stimulation Strategies for Improving the Resolution of Retinal Prostheses. Front Neurosci 2020; 14:262. [PMID: 32292328 PMCID: PMC7135883 DOI: 10.3389/fnins.2020.00262] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2019] [Accepted: 03/09/2020] [Indexed: 12/17/2022] Open
Abstract
Electrical stimulation using implantable devices with arrays of stimulating electrodes is an emerging therapy for neurological diseases. The performance of these devices depends greatly on their ability to activate populations of neurons with high spatiotemporal resolution. To study electrical stimulation of populations of neurons, retina serves as a useful model because the neural network is arranged in a planar array that is easy to access. Moreover, retinal prostheses are under development to restore vision by replacing the function of damaged light sensitive photoreceptors, which makes retinal research directly relevant for curing blindness. Here we provide a progress review on stimulation strategies developed in recent years to improve the resolution of electrical stimulation in retinal prostheses. We focus on studies performed with explanted retinas, in which electrophysiological techniques are the most advanced. We summarize achievements in improving the spatial and temporal resolution of electrical stimulation of the retina and methods to selectively stimulate neurons with different visual functions. Future directions for retinal prostheses development are also discussed, which could provide insights for other types of neuromodulatory devices in which high-resolution electrical stimulation is required.
Collapse
Affiliation(s)
- Wei Tong
- National Vision Research Institute, Australian College of Optometry, Carlton, VIC, Australia
- Department of Optometry and Vision Sciences, Melbourne School of Health Sciences, The University of Melbourne, Melbourne, VIC, Australia
- School of Physics, The University of Melbourne, Melbourne, VIC, Australia
| | - Hamish Meffin
- National Vision Research Institute, Australian College of Optometry, Carlton, VIC, Australia
- Department of Optometry and Vision Sciences, Melbourne School of Health Sciences, The University of Melbourne, Melbourne, VIC, Australia
- Department of Biomedical Engineering, The University of Melbourne, Melbourne, VIC, Australia
| | - David J. Garrett
- School of Physics, The University of Melbourne, Melbourne, VIC, Australia
| | - Michael R. Ibbotson
- National Vision Research Institute, Australian College of Optometry, Carlton, VIC, Australia
- Department of Optometry and Vision Sciences, Melbourne School of Health Sciences, The University of Melbourne, Melbourne, VIC, Australia
| |
Collapse
|
11
|
Höfling L, Oesterle J, Berens P, Zeck G. Probing and predicting ganglion cell responses to smooth electrical stimulation in healthy and blind mouse retina. Sci Rep 2020; 10:5248. [PMID: 32251331 PMCID: PMC7090015 DOI: 10.1038/s41598-020-61899-y] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2019] [Accepted: 02/19/2020] [Indexed: 11/14/2022] Open
Abstract
Retinal implants are used to replace lost photoreceptors in blind patients suffering from retinopathies such as retinitis pigmentosa. Patients wearing implants regain some rudimentary visual function. However, it is severely limited compared to normal vision because non-physiological stimulation strategies fail to selectively activate different retinal pathways at sufficient spatial and temporal resolution. The development of improved stimulation strategies is rendered difficult by the large space of potential stimuli. Here we systematically explore a subspace of potential stimuli by electrically stimulating healthy and blind mouse retina in epiretinal configuration using smooth Gaussian white noise delivered by a high-density CMOS-based microelectrode array. We identify linear filters of retinal ganglion cells (RGCs) by fitting a linear-nonlinear-Poisson (LNP) model. Our stimulus evokes spatially and temporally confined spiking responses in RGC which are accurately predicted by the LNP model. Furthermore, we find diverse shapes of linear filters in the linear stage of the model, suggesting diverse preferred electrical stimuli of RGCs. The linear filter base identified by our approach could provide a starting point of a model-guided search for improved stimuli for retinal prosthetics.
Collapse
Affiliation(s)
- Larissa Höfling
- Natural and Medical Sciences Institute at the University of Tübingen, Reutlingen, Germany
- Graduate Training Centre of Neuroscience, University of Tübingen, Tübingen, Germany
- Institute for Ophthalmic Research, University of Tübingen, Tübingen, Germany
- Centre for Integrative Neuroscience, University of Tübingen, Tübingen, Germany
| | - Jonathan Oesterle
- Institute for Ophthalmic Research, University of Tübingen, Tübingen, Germany
| | - Philipp Berens
- Institute for Ophthalmic Research, University of Tübingen, Tübingen, Germany
- Bernstein Center for Computational Neuroscience, University of Tübingen, Tübingen, Germany
- Department of Computer Science, University of Tübingen, Tübingen, Germany
| | - Günther Zeck
- Natural and Medical Sciences Institute at the University of Tübingen, Reutlingen, Germany.
- Bernstein Center for Computational Neuroscience, University of Tübingen, Tübingen, Germany.
| |
Collapse
|
12
|
Rathbun DL, Ghorbani N, Shabani H, Zrenner E, Hosseinzadeh Z. Spike-triggered average electrical stimuli as input filters for bionic vision—a perspective. J Neural Eng 2018; 15:063002. [DOI: 10.1088/1741-2552/aae493] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
|
13
|
Corna A, Herrmann T, Zeck G. Electrode-size dependent thresholds in subretinal neuroprosthetic stimulation. J Neural Eng 2018; 15:045003. [DOI: 10.1088/1741-2552/aac1c8] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
14
|
Yang CY, Tsai D, Guo T, Dokos S, Suaning GJ, Morley JW, Lovell NH. Differential electrical responses in retinal ganglion cell subtypes: effects of synaptic blockade and stimulating electrode location. J Neural Eng 2018; 15:046020. [PMID: 29737971 DOI: 10.1088/1741-2552/aac315] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
OBJECTIVE Visual prostheses have shown promising results in restoring visual perception to blind patients. The ability to differentially activate retinal ganglion cell (RGC) subtypes could further improve the efficacy of these medical devices. APPROACH Using whole-cell patch clamp, we investigated membrane potential differences between ON and OFF RGCs in the mouse retina when their synaptic inputs were blocked by synaptic blockers, and examined the differences in stimulation thresholds under such conditions. By injecting intracellular current, we further confirmed the relationship between RGC stimulation thresholds and resting membrane potentials (RMPs). In addition, we investigated the effects of stimulating electrode location on the differences in stimulation thresholds between ON and OFF RGCs. MAIN RESULTS With synaptic blockade, ON RGCs became significantly more hyperpolarized (from -61.8 ± 1.4 mV to -70.8 ± 1.6 mV), while OFF RGCs depolarized slightly (from -60.5 ± 0.7 mV to -58.6 ± 0.9 mV). RGC stimulation thresholds were negatively correlated with their RMPs (Pearson r value: -0.5154; p-value: 0.0042). Thus, depriving ON RGCs of synaptic inputs significantly increased their thresholds (from 14.7 ± 1.3 µA to 22.3 ± 2.1 µA) over those of OFF RGCs (from 13.2 ± 0.7 µA to 13.1 ± 1.1 µA). However, with control solution, ON and OFF RGC stimulation thresholds were not significantly different. Finally, placement of the stimulating electrode away from the axon enhanced differences in stimulation thresholds between ON and OFF RGCs, facilitating preferential activation of OFF RGCs. SIGNIFICANCE Since ON and OFF RGCs have antagonistic responses to natural light, achieving differential RGC activation could convey more natural visual information, leading to better visual prosthesis outcomes.
Collapse
Affiliation(s)
- Chih Yu Yang
- Graduate School of Biomedical Engineering, UNSW, Sydney, NSW 2052, Australia
| | | | | | | | | | | | | |
Collapse
|
15
|
Esler TB, Kerr RR, Tahayori B, Grayden DB, Meffin H, Burkitt AN. Minimizing activation of overlying axons with epiretinal stimulation: The role of fiber orientation and electrode configuration. PLoS One 2018; 13:e0193598. [PMID: 29494655 PMCID: PMC5833203 DOI: 10.1371/journal.pone.0193598] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2017] [Accepted: 02/14/2018] [Indexed: 12/19/2022] Open
Abstract
Currently, a challenge in electrical stimulation of the retina with a visual prosthesis (bionic eye) is to excite only the cells lying directly under the electrode in the ganglion cell layer, while avoiding excitation of axon bundles that pass over the surface of the retina in the nerve fiber layer. Stimulation of overlying axons results in irregular visual percepts, limiting perceptual efficacy. This research explores how differences in fiber orientation between the nerve fiber layer and ganglion cell layer leads to differences in the electrical activation of the axon initial segment and axons of passage. Approach. Axons of passage of retinal ganglion cells in the nerve fiber layer are characterized by a narrow distribution of fiber orientations, causing highly anisotropic spread of applied current. In contrast, proximal axons in the ganglion cell layer have a wider distribution of orientations. A four-layer computational model of epiretinal extracellular stimulation that captures the effect of neurite orientation in anisotropic tissue has been developed using a volume conductor model known as the cellular composite model. Simulations are conducted to investigate the interaction of neural tissue orientation, stimulating electrode configuration, and stimulation pulse duration and amplitude. Main results. Our model shows that simultaneous stimulation with multiple electrodes aligned with the nerve fiber layer can be used to achieve selective activation of axon initial segments rather than passing fibers. This result can be achieved while reducing required stimulus charge density and with only modest increases in the spread of activation in the ganglion cell layer, and is shown to extend to the general case of arbitrary electrode array positioning and arbitrary target volume. Significance. These results elucidate a strategy for more targeted stimulation of retinal ganglion cells with experimentally-relevant multi-electrode geometries and achievable stimulation requirements.
Collapse
Affiliation(s)
- Timothy B. Esler
- Department of Biomedical Engineering, The University of Melbourne, Parkville, Victoria, Australia
- * E-mail:
| | - Robert R. Kerr
- Department of Biomedical Engineering, The University of Melbourne, Parkville, Victoria, Australia
- Seer Medical, Melbourne, Victoria, Australia
| | - Bahman Tahayori
- Monash Institute of Medical Engineering, Monash University, Clayton, Victoria, Australia
| | - David B. Grayden
- Department of Biomedical Engineering, The University of Melbourne, Parkville, Victoria, Australia
- Centre for Neural Engineering, The University of Melbourne, Parkville, Victoria, Australia
| | - Hamish Meffin
- National Vision Research Institute, Australian College of Optometry, Carlton, Victoria, Australia
- ARC Centre of Excellence for Integrative Brain Function, Optometry & Vision Science, The University of Melbourne, Parkville, Victoria, Australia
| | - Anthony N. Burkitt
- Department of Biomedical Engineering, The University of Melbourne, Parkville, Victoria, Australia
| |
Collapse
|
16
|
Weiland JD, Walston ST, Humayun MS. Electrical Stimulation of the Retina to Produce Artificial Vision. Annu Rev Vis Sci 2018; 2:273-294. [PMID: 28532361 DOI: 10.1146/annurev-vision-111815-114425] [Citation(s) in RCA: 44] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Retinal prostheses aim to restore vision to blind individuals suffering from retinal diseases such as retinitis pigmentosa and age-related macular degeneration. These devices function by electrically stimulating surviving retinal neurons, whose activation is interpreted by the brain as a visual percept. Many prostheses are currently under development. They are categorized as epiretinal, subretinal, and suprachoroidal prostheses on the basis of the placement of the stimulating microelectrode array. Each can activate ganglion cells through direct or indirect stimulation. The response of retinal neurons to these modes of stimulation are discussed in detail and are placed in context of the visual percept they are likely to evoke. This article further reviews challenges faced by retinal prosthesis and discusses potential solutions to address them.
Collapse
Affiliation(s)
- James D Weiland
- Department of Biomedical Engineering, University of Southern California, Los Angeles, California 90007; .,USC Roski Eye Institute, University of Southern California, Los Angeles, California 90033.,Institute for Biomedical Therapeutics, University of Southern California, Los Angeles, California 90033
| | - Steven T Walston
- Department of Biomedical Engineering, University of Southern California, Los Angeles, California 90007;
| | - Mark S Humayun
- Department of Biomedical Engineering, University of Southern California, Los Angeles, California 90007; .,USC Roski Eye Institute, University of Southern California, Los Angeles, California 90033.,Institute for Biomedical Therapeutics, University of Southern California, Los Angeles, California 90033
| |
Collapse
|
17
|
Watterson WJ, Montgomery RD, Taylor RP. Fractal Electrodes as a Generic Interface for Stimulating Neurons. Sci Rep 2017; 7:6717. [PMID: 28751652 PMCID: PMC5532230 DOI: 10.1038/s41598-017-06762-3] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2016] [Accepted: 06/19/2017] [Indexed: 12/03/2022] Open
Abstract
The prospect of replacing damaged body parts with artificial implants is being transformed from science fiction to science fact through the increasing application of electronics to interface with human neurons in the limbs, the brain, and the retina. We propose bio-inspired electronics which adopt the fractal geometry of the neurons they interface with. Our focus is on retinal implants, although performance improvements will be generic to many neuronal types. The key component is a multifunctional electrode; light passes through this electrode into a photodiode which charges the electrode. Its electric field then stimulates the neurons. A fractal electrode might increase both light transmission and neuron proximity compared to conventional Euclidean electrodes. These advantages are negated if the fractal’s field is less effective at stimulating neurons. We present simulations demonstrating how an interplay of fractal properties generates enhanced stimulation; the electrode voltage necessary to stimulate all neighboring neurons is over 50% less for fractal than Euclidean electrodes. This smaller voltage can be achieved by a single diode compared to three diodes required for the Euclidean electrode’s higher voltage. This will allow patients, for the first time, to see with the visual acuity necessary for navigating rooms and streets.
Collapse
Affiliation(s)
- W J Watterson
- Physics Department, University of Oregon, Eugene, OR, 97403, USA.
| | - R D Montgomery
- Physics Department, University of Oregon, Eugene, OR, 97403, USA
| | - R P Taylor
- Physics Department, University of Oregon, Eugene, OR, 97403, USA
| |
Collapse
|
18
|
Lehto LJ, Slopsema JP, Johnson MD, Shatillo A, Teplitzky BA, Utecht L, Adriany G, Mangia S, Sierra A, Low WC, Gröhn O, Michaeli S. Orientation selective deep brain stimulation. J Neural Eng 2017; 14:016016. [PMID: 28068296 DOI: 10.1088/1741-2552/aa5238] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVE Target selectivity of deep brain stimulation (DBS) therapy is critical, as the precise locus and pattern of the stimulation dictates the degree to which desired treatment responses are achieved and adverse side effects are avoided. There is a clear clinical need to improve DBS technology beyond currently available stimulation steering and shaping approaches. We introduce orientation selective neural stimulation as a concept to increase the specificity of target selection in DBS. APPROACH This concept, which involves orienting the electric field along an axonal pathway, was tested in the corpus callosum of the rat brain by freely controlling the direction of the electric field on a plane using a three-electrode bundle, and monitoring the response of the neurons using functional magnetic resonance imaging (fMRI). Computational models were developed to further analyze axonal excitability for varied electric field orientation. MAIN RESULTS Our results demonstrated that the strongest fMRI response was observed when the electric field was oriented parallel to the axons, while almost no response was detected with the perpendicular orientation of the electric field relative to the primary fiber tract. These results were confirmed by computational models of the experimental paradigm quantifying the activation of radially distributed axons while varying the primary direction of the electric field. SIGNIFICANCE The described strategies identify a new course for selective neuromodulation paradigms in DBS based on axonal fiber orientation.
Collapse
Affiliation(s)
- Lauri J Lehto
- Center for Magnetic Resonance Research, Radiology, University of Minnesota, 2021 6th St SE, Minneapolis, MN 55455, USA
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
19
|
A spectral element method with adaptive segmentation for accurately simulating extracellular electrical stimulation of neurons. Med Biol Eng Comput 2016; 55:823-831. [PMID: 27541303 DOI: 10.1007/s11517-016-1558-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2016] [Accepted: 07/30/2016] [Indexed: 10/21/2022]
Abstract
The capacity to quickly and accurately simulate extracellular stimulation of neurons is essential to the design of next-generation neural prostheses. Existing platforms for simulating neurons are largely based on finite-difference techniques; due to the complex geometries involved, the more powerful spectral or differential quadrature techniques cannot be applied directly. This paper presents a mathematical basis for the application of a spectral element method to the problem of simulating the extracellular stimulation of retinal neurons, which is readily extensible to neural fibers of any kind. The activating function formalism is extended to arbitrary neuron geometries, and a segmentation method to guarantee an appropriate choice of collocation points is presented. Differential quadrature may then be applied to efficiently solve the resulting cable equations. The capacity for this model to simulate action potentials propagating through branching structures and to predict minimum extracellular stimulation thresholds for individual neurons is demonstrated. The presented model is validated against published values for extracellular stimulation threshold and conduction velocity for realistic physiological parameter values. This model suggests that convoluted axon geometries are more readily activated by extracellular stimulation than linear axon geometries, which may have ramifications for the design of neural prostheses.
Collapse
|
20
|
Electrical Identification and Selective Microstimulation of Neuronal Compartments Based on Features of Extracellular Action Potentials. Sci Rep 2016; 6:31332. [PMID: 27510732 PMCID: PMC4980679 DOI: 10.1038/srep31332] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2016] [Accepted: 07/18/2016] [Indexed: 11/30/2022] Open
Abstract
A detailed, high-spatiotemporal-resolution characterization of neuronal responses to local electrical fields and the capability of precise extracellular microstimulation of selected neurons are pivotal for studying and manipulating neuronal activity and circuits in networks and for developing neural prosthetics. Here, we studied cultured neocortical neurons by using high-density microelectrode arrays and optical imaging, complemented by the patch-clamp technique, and with the aim to correlate morphological and electrical features of neuronal compartments with their responsiveness to extracellular stimulation. We developed strategies to electrically identify any neuron in the network, while subcellular spatial resolution recording of extracellular action potential (AP) traces enabled their assignment to the axon initial segment (AIS), axonal arbor and proximal somatodendritic compartments. Stimulation at the AIS required low voltages and provided immediate, selective and reliable neuronal activation, whereas stimulation at the soma required high voltages and produced delayed and unreliable responses. Subthreshold stimulation at the soma depolarized the somatic membrane potential without eliciting APs.
Collapse
|
21
|
Stutzki H, Helmhold F, Eickenscheidt M, Zeck G. Subretinal electrical stimulation reveals intact network activity in the blind mouse retina. J Neurophysiol 2016; 116:1684-1693. [PMID: 27486110 DOI: 10.1152/jn.01095.2015] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2015] [Accepted: 07/12/2016] [Indexed: 11/22/2022] Open
Abstract
Retinal degeneration (rd) leads to progressive photoreceptor cell death, resulting in vision loss. Stimulation of the inner-retinal neurons by neuroprosthetic implants is one of the clinically approved vision-restoration strategies, providing basic visual percepts to blind patients. However, little is understood as to what degree the degenerating retinal circuitry and the resulting aberrant hyperactivity may prevent the stimulation of physiological electrical activity. Therefore, we electrically stimulated ex vivo retinas from wild-type (wt; C57BL/6J) and blind (rd10 and rd1) mice using an implantable subretinal microchip and simultaneously recorded and analyzed the retinal ganglion cell (RGC) output with a flexible microelectrode array. We found that subretinal anodal stimulation of the rd10 retina and wt retina evoked similar spatiotemporal RGC-spiking patterns. In both retinas, electrically stimulated ON and a small percentage of OFF RGC responses were detected. The spatial selectivity of the retinal network to electrical stimuli reveals an intact underlying network with a median receptive-field center of 350 μm in both retinas. An antagonistic surround is activated by stimulation with large electrode fields. However, in rd10 and to a higher percentage, in rd1 retinas, rhythmic and spatially unconfined RGC patterns were evoked by anodal or by cathodal electrical stimuli. Our findings demonstrate that the surviving retinal circuitry in photoreceptor-degenerated retinas is preserved in a way allowing for the stimulation of temporally diverse and spatially confined RGC activity. Future vision restoration strategies can build on these results but need to avoid evoking the easily inducible rhythmic activity in some retinal circuits.
Collapse
Affiliation(s)
- Henrike Stutzki
- Natural and Medical Sciences Institute at the University of Tübingen, Reutlingen, Germany; and Graduate School of Neural and Behavioural Sciences/International Max Planck Research School, Tübingen, Germany
| | - Florian Helmhold
- Natural and Medical Sciences Institute at the University of Tübingen, Reutlingen, Germany; and
| | - Max Eickenscheidt
- Natural and Medical Sciences Institute at the University of Tübingen, Reutlingen, Germany; and
| | - Günther Zeck
- Natural and Medical Sciences Institute at the University of Tübingen, Reutlingen, Germany; and
| |
Collapse
|
22
|
Müller J, Ballini M, Livi P, Chen Y, Radivojevic M, Shadmani A, Viswam V, Jones IL, Fiscella M, Diggelmann R, Stettler A, Frey U, Bakkum DJ, Hierlemann A. High-resolution CMOS MEA platform to study neurons at subcellular, cellular, and network levels. LAB ON A CHIP 2015; 15:2767-80. [PMID: 25973786 PMCID: PMC5421573 DOI: 10.1039/c5lc00133a] [Citation(s) in RCA: 145] [Impact Index Per Article: 16.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/02/2023]
Abstract
Studies on information processing and learning properties of neuronal networks would benefit from simultaneous and parallel access to the activity of a large fraction of all neurons in such networks. Here, we present a CMOS-based device, capable of simultaneously recording the electrical activity of over a thousand cells in in vitro neuronal networks. The device provides sufficiently high spatiotemporal resolution to enable, at the same time, access to neuronal preparations on subcellular, cellular, and network level. The key feature is a rapidly reconfigurable array of 26 400 microelectrodes arranged at low pitch (17.5 μm) within a large overall sensing area (3.85 × 2.10 mm(2)). An arbitrary subset of the electrodes can be simultaneously connected to 1024 low-noise readout channels as well as 32 stimulation units. Each electrode or electrode subset can be used to electrically stimulate or record the signals of virtually any neuron on the array. We demonstrate the applicability and potential of this device for various different experimental paradigms: large-scale recordings from whole networks of neurons as well as investigations of axonal properties of individual neurons.
Collapse
Affiliation(s)
- Jan Müller
- ETH Zurich, Bio Engineering Laboratory, Department of Biosystems Science and Engineering, Mattenstrasse 26, CH-4058 Basel, Switzerland.
| | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
23
|
Rattay F. On the upper threshold phenomenon of extracellular neural stimulation. J Neurophysiol 2015; 112:2664-5. [PMID: 25399448 DOI: 10.1152/jn.00323.2014] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Affiliation(s)
- Frank Rattay
- Institute of Analysis and Scientific Computing, TU Vienna, Austria
| |
Collapse
|
24
|
Samba R, Herrmann T, Zeck G. PEDOT–CNT coated electrodes stimulate retinal neurons at low voltage amplitudes and low charge densities. J Neural Eng 2015; 12:016014. [DOI: 10.1088/1741-2560/12/1/016014] [Citation(s) in RCA: 62] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|