1
|
Augière T, Simoneau M, Mercier C. Visuotactile integration in individuals with fibromyalgia. Front Hum Neurosci 2024; 18:1390609. [PMID: 38826615 PMCID: PMC11140151 DOI: 10.3389/fnhum.2024.1390609] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2024] [Accepted: 04/29/2024] [Indexed: 06/04/2024] Open
Abstract
Our brain constantly integrates afferent information, such as visual and tactile information, to perceive the world around us. According to the maximum-likelihood estimation (MLE) model, imprecise information will be weighted less than precise, making the multisensory percept as precise as possible. Individuals with fibromyalgia (FM), a chronic pain syndrome, show alterations in the integration of tactile information. This could lead to a decrease in their weight in a multisensory percept or a general disruption of multisensory integration, making it less beneficial. To assess multisensory integration, 15 participants with FM and 18 pain-free controls performed a temporal-order judgment task in which they received pairs of sequential visual, tactile (unisensory conditions), or visuotactile (multisensory condition) stimulations on the index and the thumb of the non-dominant hand and had to determine which finger was stimulated first. The task enabled us to measure the precision and accuracy of the percept in each condition. Results indicate an increase in precision in the visuotactile condition compared to the unimodal conditions in controls only, although we found no intergroup differences. The observed visuotactile precision was correlated to the precision predicted by the MLE model in both groups, suggesting an optimal integration. Finally, the weights of the sensory information were not different between the groups; however, in the group with FM, higher pain intensity was associated with smaller tactile weight. This study shows no alterations of the visuotactile integration in individuals with FM, though pain may influence tactile weight in these participants.
Collapse
Affiliation(s)
- Tania Augière
- Center for Interdisciplinary Research in Rehabilitation and Social Integration (Cirris), CIUSSS de la Capitale-Nationale, Quebec, QC, Canada
- School of Rehabilitation Sciences, Faculty of Medicine, Laval University, Quebec, QC, Canada
| | - Martin Simoneau
- Center for Interdisciplinary Research in Rehabilitation and Social Integration (Cirris), CIUSSS de la Capitale-Nationale, Quebec, QC, Canada
- Department of Kinesiology, Faculty of Medicine, Laval University, Quebec, QC, Canada
| | - Catherine Mercier
- Center for Interdisciplinary Research in Rehabilitation and Social Integration (Cirris), CIUSSS de la Capitale-Nationale, Quebec, QC, Canada
- School of Rehabilitation Sciences, Faculty of Medicine, Laval University, Quebec, QC, Canada
| |
Collapse
|
2
|
Henrich MC, Garenfeld MA, Malesevic J, Strbac M, Dosen S. Encoding contact size using static and dynamic electrotactile finger stimulation: natural decoding vs. trained cues. Exp Brain Res 2024; 242:1047-1060. [PMID: 38467759 PMCID: PMC11078849 DOI: 10.1007/s00221-024-06794-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2023] [Accepted: 01/24/2024] [Indexed: 03/13/2024]
Abstract
Electrotactile stimulation through matrix electrodes is a promising technology to restore high-resolution tactile feedback in extended reality applications. One of the fundamental tactile effects that should be simulated is the change in the size of the contact between the finger and a virtual object. The present study investigated how participants perceive the increase of stimulation area when stimulating the index finger using static or dynamic (moving) stimuli produced by activating 1 to 6 electrode pads. To assess the ability to interpret the stimulation from the natural cues (natural decoding), without any prior training, the participants were instructed to draw the size of the stimulated area and identify the size difference when comparing two consecutive stimulations. To investigate if other "non-natural" cues can improve the size estimation, the participants were asked to enumerate the number of active pads following a training protocol. The results demonstrated that participants could perceive the change in size without prior training (e.g., the estimated area correlated with the stimulated area, p < 0.001; ≥ two-pad difference recognized with > 80% success rate). However, natural decoding was also challenging, as the response area changed gradually and sometimes in complex patterns when increasing the number of active pads (e.g., four extra pads needed for the statistically significant difference). Nevertheless, by training the participants to utilize additional cues the limitations of natural perception could be compensated. After the training, the mismatch in the activated and estimated number of pads was less than one pad regardless of the stimulus size. Finally, introducing the movement of the stimulus substantially improved discrimination (e.g., 100% median success rate to recognize ≥ one-pad difference). The present study, therefore, provides insights into stimulation size perception, and practical guidelines on how to modulate pad activation to change the perceived size in static and dynamic scenarios.
Collapse
Affiliation(s)
- Mauricio Carlos Henrich
- Department of Health Science and Technology, Aalborg University, Selma Lagerløfs Vej 249, 9260, Gistrup, Denmark
| | - Martin A Garenfeld
- Department of Health Science and Technology, Aalborg University, Selma Lagerløfs Vej 249, 9260, Gistrup, Denmark
| | | | - Matija Strbac
- Tecnalia Serbia Ltd, Deligradska 9/39, 11000, Belgrade, Serbia
| | - Strahinja Dosen
- Department of Health Science and Technology, Aalborg University, Selma Lagerløfs Vej 249, 9260, Gistrup, Denmark.
| |
Collapse
|
3
|
Bader ER, Boro AD, Killian NJ, Eskandar EN. A method for precisely timed, on-demand intracranial stimulation using the RNS device. Brain Stimul 2024; 17:444-447. [PMID: 38554856 DOI: 10.1016/j.brs.2024.03.020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2024] [Revised: 03/20/2024] [Accepted: 03/24/2024] [Indexed: 04/02/2024] Open
Affiliation(s)
- Edward R Bader
- Department of Neurological Surgery, Albert Einstein College of Medicine, Bronx, NY, USA.
| | - Alexis D Boro
- Department of Neurology, Albert Einstein College of Medicine, Bronx, NY, USA
| | - Nathaniel J Killian
- Department of Neurological Surgery, Albert Einstein College of Medicine, Bronx, NY, USA
| | - Emad N Eskandar
- Department of Neurological Surgery, Albert Einstein College of Medicine, Bronx, NY, USA
| |
Collapse
|
4
|
Malešević J, Kostić M, Jure FA, Spaich EG, Došen S, Ilić V, Bijelić G, Štrbac M. Electrotactile Communication via Matrix Electrode Placed on the Torso Using Fast Calibration, and Static vs. Dynamic Encoding. SENSORS (BASEL, SWITZERLAND) 2022; 22:7658. [PMID: 36236758 PMCID: PMC9572222 DOI: 10.3390/s22197658] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/16/2022] [Revised: 10/05/2022] [Accepted: 10/07/2022] [Indexed: 06/16/2023]
Abstract
Electrotactile stimulation is a technology that reproducibly elicits tactile sensations and can be used as an alternative channel to communicate information to the user. The presented work is a part of an effort to develop this technology into an unobtrusive communication tool for first responders. In this study, the aim was to compare the success rate (SR) between discriminating stimulation at six spatial locations (static encoding) and recognizing six spatio-temporal patterns where pads are activated sequentially in a predetermined order (dynamic encoding). Additionally, a procedure for a fast amplitude calibration, that includes a semi-automated initialization and an optional manual adjustment, was employed and evaluated. Twenty subjects, including twelve first responders, participated in the study. The electrode comprising the 3 × 2 matrix of pads was placed on the lateral torso. The results showed that high SRs could be achieved for both types of message encoding after a short learning phase; however, the dynamic approach led to a statistically significant improvement in messages recognition (SR of 93.3%), compared to static stimulation (SR of 83.3%). The proposed calibration procedure was also effective since in 83.8% of the cases the subjects did not need to adjust the stimulation amplitude manually.
Collapse
Affiliation(s)
| | | | - Fabricio A. Jure
- Neurorehabilitation Systems, Department of Health Science and Technology, Faculty of Medicine, Aalborg University, 9220 Aalborg, Denmark
| | - Erika G. Spaich
- Neurorehabilitation Systems, Department of Health Science and Technology, Faculty of Medicine, Aalborg University, 9220 Aalborg, Denmark
| | - Strahinja Došen
- Neurorehabilitation Systems, Department of Health Science and Technology, Faculty of Medicine, Aalborg University, 9220 Aalborg, Denmark
| | - Vojin Ilić
- Department of Computing and Control Engineering, Faculty of Technical Sciences, University of Novi Sad, 21102 Novi Sad, Serbia
| | - Goran Bijelić
- Tecnalia, Basque Research and Technology Alliance (BRTA), 20009 Donostia-San Sebastian, Spain
| | | |
Collapse
|
5
|
Dideriksen J, Markovic M, Lemling S, Farina D, Dosen S. Electrotactile and Vibrotactile Feedback Enable Similar Performance in Psychometric Tests and Closed-Loop Control. IEEE TRANSACTIONS ON HAPTICS 2022; 15:222-231. [PMID: 34618676 DOI: 10.1109/toh.2021.3117628] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Electro- and vibro-tactile stimulation are commonly employed for feedback in closed-loop human-machine interfacing. Although these feedback systems have been extensively investigated individually, they are rarely objectively compared. In this study, two state-of-the-art stimulation units (concentric electrode and C2-tactor) similar in shape and size were compared in psychometric and online control tests. The just noticeable difference and number of discriminable levels for intensity and frequency modulation were determined across values of carrier frequency and intensity, respectively. Next, subjects performed a compensatory tracking task, in which the feedback encoded the momentary tracking error. In the psychometric tests, intensity modulation outperformed frequency modulation and electrotactile stimulation enabled significantly higher resolution than vibrotactile stimulation, for the same carrier frequency. However, for the best-case settings (eletro-tactile: 100 Hz; vibro-tactile: 200 Hz), the two stimulation modalities were equivalent in the psychometric tests and in the online control tests, where the two stimulation methods resulted in similar correlation and deviation between the target and the generated trajectory. Time delay was slightly but significantly lower for the vibrotactile modality. Overall, the present assessment shows that despite psychometric differences between the two stimulation methods, they enable similar online control performance when parameters are optimally selected for each modality.
Collapse
|
6
|
Ng KKW, Tee X, Vickery RM, Birznieks I. The Relationship Between Tactile Intensity Perception and Afferent Spike Count is Moderated by a Function of Frequency. IEEE TRANSACTIONS ON HAPTICS 2022; 15:14-19. [PMID: 34990370 DOI: 10.1109/toh.2022.3140877] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
It has been suggested that tactile intensity perception can be explained by a linear function of spike rate weighted by afferent type. Other than relying on mathematical models, verifying this experimentally is difficult due to the frequency tuning of different afferent types and changes in population recruitment patterns with vibrotactile frequency. To overcome these complexities, we used pulsatile mechanical stimuli which activate the same afferent population regardless of the repetition rate (frequency), generating one action potential per pulse. We used trains of different frequencies (20-200 Hz) to investigate perceived intensity. Subjects' magnitude ratings increased with pulse rate up to ∼100 Hz and plateaued beyond this frequency. This was true regardless of pulse amplitude, from small pulses that exclusively activated Pacinian (PC) afferents, to pulses large enough to activate other afferents including slowly adapting. Electrical stimulation, which activates afferents indiscriminately, plateaued at a similar frequency, although not in all subjects. As the plateauing did not depend on indentation magnitude and hence on afferent weights, we propose that the contribution of spike count to intensity perception is weighted by a function of frequency. This may explain why fine textures evoking high frequency vibrations of a small magnitude do not feel disproportionally intense.
Collapse
|
7
|
Blondin CM, Ivanova E, Eden J, Burdet E. Perception and Performance of Electrical Stimulation for Proprioception. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2021; 2021:4550-4554. [PMID: 34892229 DOI: 10.1109/embc46164.2021.9630186] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Proprioception, yielding awareness of the body's position and motion in space, is typically lacking in prostheses and supernumerary limbs. Electrical stimulation is one technique that may provide these devices with proprioception. This paper first investigates how the modalities of electrotactile cues, such as frequency and intensity, are perceived. Using the results, we designed and compared several comfortable and perceptible feedback mappings for spatial cues. Two experiments were conducted using a 16-electrode bracelet worn above the elbow to provide electrical stimuli. We found that subjects could localize the stimulating electrode with a precision of ±1 electrode (110 mm) in all feedback conditions. Moreover, within the range of pulse intensities perceived as comfortable, the participants' performance was more sensitive to changes in frequency than in intensity. The highest performance was obtained for the condition which increased both intensity and frequency with radial distance. These results suggest that electrical stimulation can be used for artificial proprioceptive feedback, which can ensure a comfortable and intuitive interaction and provides high spatial accuracy.
Collapse
|
8
|
Nataletti S, Leo F, Seminara L, Trompetto C, Valle M, Dosen S, Brayda L. Temporal Asynchrony but Not Total Energy Nor Duration Improves the Judgment of Numerosity in Electrotactile Stimulation. Front Bioeng Biotechnol 2020; 8:555. [PMID: 32656190 PMCID: PMC7325877 DOI: 10.3389/fbioe.2020.00555] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2019] [Accepted: 05/07/2020] [Indexed: 11/13/2022] Open
Abstract
Stroke patients suffer from impairments of both motor and somatosensory functions. The functional recovery of upper extremities is one of the primary goals of rehabilitation programs. Additional somatosensory deficits limit sensorimotor function and significantly affect its recovery after the neuromotor injury. Sensory substitution systems, providing tactile feedback, might facilitate manipulation capability, and improve patient's dexterity during grasping movements. As a first step toward this aim, we evaluated the ability of healthy subjects in exploiting electrotactile feedback on the shoulder to determine the number of perceived stimuli in numerosity judgment tasks. During the experiment, we compared four different stimulation patterns (two simultaneous: short and long, intermittent and sequential) differing in total duration, total energy, or temporal synchrony. The experiment confirmed that the subject ability to enumerate electrotactile stimuli decreased with increasing the number of active electrodes. Furthermore, we found that, in electrotactile stimulation, the temporal coding schemes, and not total energy or duration modulated the accuracy in numerosity judgment. More precisely, the sequential condition resulted in significantly better numerosity discrimination than intermittent and simultaneous stimulation. These findings, together with the fact that the shoulder appeared to be a feasible stimulation site to communicate tactile information via electrotactile feedback, can serve as a guide to deliver tactile feedback to proximal areas in stroke survivors who lack sensory integrity in distal areas of their affected arm, but retain motor skills.
Collapse
Affiliation(s)
- Sara Nataletti
- Robotics, Brain and Cognitive Science Department, Istituto Italiano di Tecnologia, Genoa, Italy.,Department of Informatics Bioengineering Robotics, and System Engineering, University of Genoa, Genoa, Italy
| | - Fabrizio Leo
- Robotics, Brain and Cognitive Science Department, Istituto Italiano di Tecnologia, Genoa, Italy
| | - Lucia Seminara
- Department of Electrical, Electronic, Telecommunications Engineering and Naval Architecture, University of Genoa, Genoa, Italy
| | - Carlo Trompetto
- Department of Neuroscience, IRCCS Ospedale Policlinico San Martino, Genoa, Italy.,Department of Neuroscience, Rehabilitation, Ophthalmology, Genetics and Maternal and Child Sciences, University of Genoa, Genoa, Italy
| | - Maurizio Valle
- Department of Electrical, Electronic, Telecommunications Engineering and Naval Architecture, University of Genoa, Genoa, Italy
| | - Strahinja Dosen
- Department of Health Science and Technology, Faculty of Medicine, Aalborg University, Aalborg, Denmark
| | - Luca Brayda
- Robotics, Brain and Cognitive Science Department, Istituto Italiano di Tecnologia, Genoa, Italy.,Acoesis Inc., Genoa, Italy
| |
Collapse
|
9
|
Wilke MA, Niethammer C, Meyer B, Farina D, Dosen S. Psychometric characterization of incidental feedback sources during grasping with a hand prosthesis. J Neuroeng Rehabil 2019; 16:155. [PMID: 31823792 PMCID: PMC6902515 DOI: 10.1186/s12984-019-0622-9] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2019] [Accepted: 11/13/2019] [Indexed: 11/17/2022] Open
Abstract
Background A prosthetic system should ideally reinstate the bidirectional communication between the user’s brain and its end effector by restoring both motor and sensory functions lost after an amputation. However, current commercial prostheses generally do not incorporate somatosensory feedback. Even without explicit feedback, grasping using a prosthesis partly relies on sensory information. Indeed, the prosthesis operation is characterized by visual and sound cues that could be exploited by the user to estimate the prosthesis state. However, the quality of this incidental feedback has not been objectively evaluated. Methods In this study, the psychometric properties of the auditory and visual feedback of prosthesis motion were assessed and compared to that of a vibro-tactile interface. Twelve able-bodied subjects passively observed prosthesis closing and grasping an object, and they were asked to discriminate (experiment I) or estimate (experiment II) the closing velocity of the prosthesis using visual (VIS), acoustic (SND), or combined (VIS + SND) feedback. In experiment II, the subjects performed the task also with a vibrotactile stimulus (VIB) delivered using a single tactor. The outcome measures for the discrimination and estimation experiments were just noticeable difference (JND) and median absolute estimation error (MAE), respectively. Results The results demonstrated that the incidental sources provided a remarkably good discrimination and estimation of the closing velocity, significantly outperforming the vibrotactile feedback. Using incidental sources, the subjects could discriminate almost the minimum possible increment/decrement in velocity that could be commanded to the prosthesis (median JND < 2% for SND and VIS + SND). Similarly, the median MAE in estimating the prosthesis velocity randomly commanded from the full working range was also low, i.e., approximately 5% in SND and VIS + SND. Conclusions Since the closing velocity is proportional to grasping force in state-of-the-art myoelectric prostheses, the results of the present study imply that the incidental feedback, when available, could be usefully exploited for grasping force control. Therefore, the impact of incidental feedback needs to be considered when designing a feedback interface in prosthetics, especially since the quality of estimation using supplemental sources (e.g., vibration) can be worse compared to that of the intrinsic cues.
Collapse
Affiliation(s)
- Meike Annika Wilke
- Department of Biotechnology, University for Applied Sciences Hamburg, Hamburg, Germany. .,Advanced Rehabilitation Technology (ART) Lab, Department for Trauma Surgery, Orthopaedics and Plastic Surgery, Universitätsmedizin Göttingen (UMG), Göttingen, Germany.
| | - Christian Niethammer
- Advanced Rehabilitation Technology (ART) Lab, Department for Trauma Surgery, Orthopaedics and Plastic Surgery, Universitätsmedizin Göttingen (UMG), Göttingen, Germany.,Department of Computer Science, Eberhard-Karls University Tübingen, Tübingen, Germany
| | - Britta Meyer
- Advanced Rehabilitation Technology (ART) Lab, Department for Trauma Surgery, Orthopaedics and Plastic Surgery, Universitätsmedizin Göttingen (UMG), Göttingen, Germany
| | - Dario Farina
- Advanced Rehabilitation Technology (ART) Lab, Department for Trauma Surgery, Orthopaedics and Plastic Surgery, Universitätsmedizin Göttingen (UMG), Göttingen, Germany.,Department of Bioengineering, Imperial College London, London, UK
| | - Strahinja Dosen
- Advanced Rehabilitation Technology (ART) Lab, Department for Trauma Surgery, Orthopaedics and Plastic Surgery, Universitätsmedizin Göttingen (UMG), Göttingen, Germany.,Department of Health Science and Technology, Center for Sensory-Motor Interaction, Aalborg University, Aalborg, Denmark
| |
Collapse
|
10
|
Arakeri TJ, Hasse BA, Fuglevand AJ. Object discrimination using electrotactile feedback. J Neural Eng 2018; 15:046007. [PMID: 29629874 DOI: 10.1088/1741-2552/aabc9a] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
OBJECTIVE A variety of bioengineering systems are being developed to restore tactile sensations in individuals who have lost somatosensory feedback because of spinal cord injury, stroke, or amputation. These systems typically detect tactile force with sensors placed on an insensate hand (or prosthetic hand in the case of amputees) and deliver touch information by electrically or mechanically stimulating sensate skin above the site of injury. Successful object manipulation, however, also requires proprioceptive feedback representing the configuration and movements of the hand and digits. APPROACH Therefore, we developed a simple system that simultaneously provides information about tactile grip force and hand aperture using current amplitude-modulated electrotactile feedback. We evaluated the utility of this system by testing the ability of eight healthy human subjects to distinguish among 27 objects of varying sizes, weights, and compliances based entirely on electrotactile feedback. The feedback was modulated by grip-force and hand-aperture sensors placed on the hand of an experimenter (not visible to the subject) grasping and lifting the test objects. We were also interested to determine the degree to which subjects could learn to use such feedback when tested over five consecutive sessions. MAIN RESULTS The average percentage correct identifications on day 1 (28.5% ± 8.2% correct) was well above chance (3.7%) and increased significantly with training to 49.2% ± 10.6% on day 5. Furthermore, this training transferred reasonably well to a set of novel objects. SIGNIFICANCE These results suggest that simple, non-invasive methods can provide useful multisensory feedback that might prove beneficial in improving the control over prosthetic limbs.
Collapse
Affiliation(s)
- Tapas J Arakeri
- Department of Physiology, College of Medicine, University of Arizona, Tucson AZ, United states of America
| | | | | |
Collapse
|
11
|
Virtual grasping: closed-loop force control using electrotactile feedback. COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE 2014; 2014:120357. [PMID: 24516504 PMCID: PMC3909980 DOI: 10.1155/2014/120357] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/27/2013] [Accepted: 11/20/2013] [Indexed: 11/29/2022]
Abstract
Closing the control loop by providing somatosensory feedback to the user of a prosthesis is a well-known, long standing challenge in the field of prosthetics. Various approaches have been investigated for feedback restoration, ranging from direct neural stimulation to noninvasive sensory substitution methods. Although there are many studies presenting closed-loop systems, only a few of them objectively evaluated the closed-loop performance, mostly using vibrotactile stimulation. Importantly, the conclusions about the utility of the feedback were partly contradictory. The goal of the current study was to systematically investigate the capability of human subjects to control grasping force in closed loop using electrotactile feedback. We have developed a realistic experimental setup for virtual grasping, which operated in real time, included a set of real life objects, as well as a graphical and dynamical model of the prosthesis. We have used the setup to test 10 healthy, able bodied subjects to investigate the role of training, feedback and feedforward control, robustness of the closed loop, and the ability of the human subjects to generalize the control to previously “unseen” objects. Overall, the outcomes of this study are very optimistic with regard to the benefits of feedback and reveal various, practically relevant, aspects of closed-loop control.
Collapse
|
12
|
Mugge W, Abbink DA, Schouten AC, van der Helm FCT, Arendzen JH, Meskers CGM. Force control in the absence of visual and tactile feedback. Exp Brain Res 2012; 224:635-45. [PMID: 23223780 DOI: 10.1007/s00221-012-3341-z] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2012] [Accepted: 11/06/2012] [Indexed: 10/27/2022]
Abstract
Motor control tasks like stance or object handling require sensory feedback from proprioception, vision and touch. The distinction between tactile and proprioceptive sensors is not frequently made in dynamic motor control tasks, and if so, mostly based on signal latency. We previously found that force control tasks entail more compliant behavior than a passive, relaxed condition and by neuromuscular modeling we were able to attribute this to adaptations in proprioceptive force feedback from Golgi tendon organs. This required the assumption that both tactile and visual feedback are too slow to explain the measured adaptations in face of unpredictable force perturbations. Although this assumption was shown to hold using model simulations, so far no experimental data is available to validate it. Here we applied a systematic approach using continuous perturbations and engineering analyses to provide experimental evidence for the hypothesis that motor control adaptation in force control tasks can be achieved using proprioceptive feedback only. Varying task instruction resulted in substantial adaptations in neuromuscular behavior, which persisted after eliminating visual and/or tactile feedback by a nerve block of the nervus plantaris medialis. It is concluded that proprioception adapts dynamic human ankle motor control even in the absence of visual and tactile feedback.
Collapse
Affiliation(s)
- Winfred Mugge
- Department of BioMechanical Engineering, Delft University of Technology, Mekelweg 2, 2628 CD, Delft, The Netherlands.
| | | | | | | | | | | |
Collapse
|