1
|
Cui H, Wu Q, Zhao Z, Wang Y, Lu H. Selective Capture-Based Single-Cell Mass Spectrometry for Enhancing Sphingolipid Profiling of Neurons with Differentiation of Cell Body from Synapse. Anal Chem 2022; 94:15729-15737. [DOI: 10.1021/acs.analchem.2c03336] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Hao Cui
- College of Chemistry and Chemical Engineering, Central South University, Hunan, Changsha 410083, P.R. China
| | - Qian Wu
- College of Chemistry and Chemical Engineering, Central South University, Hunan, Changsha 410083, P.R. China
| | - Zhihao Zhao
- College of Chemistry and Chemical Engineering, Central South University, Hunan, Changsha 410083, P.R. China
| | - Yang Wang
- Laboratory of Ethnopharmacology, Institute of Integrated Traditional Chinese and Western Medicine, Xiangya Hospital, Central South University, Hunan, Changsha 410008, P.R. China
| | - Hongmei Lu
- College of Chemistry and Chemical Engineering, Central South University, Hunan, Changsha 410083, P.R. China
| |
Collapse
|
2
|
Saffioti NA, Cavalcanti-Adam EA, Pallarola D. Biosensors for Studies on Adhesion-Mediated Cellular Responses to Their Microenvironment. Front Bioeng Biotechnol 2020; 8:597950. [PMID: 33262979 PMCID: PMC7685988 DOI: 10.3389/fbioe.2020.597950] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2020] [Accepted: 10/12/2020] [Indexed: 12/28/2022] Open
Abstract
Cells interact with their microenvironment by constantly sensing mechanical and chemical cues converting them into biochemical signals. These processes allow cells to respond and adapt to changes in their environment, and are crucial for most cellular functions. Understanding the mechanism underlying this complex interplay at the cell-matrix interface is of fundamental value to decipher key biochemical and mechanical factors regulating cell fate. The combination of material science and surface chemistry aided in the creation of controllable environments to study cell mechanosensing and mechanotransduction. Biologically inspired materials tailored with specific bioactive molecules, desired physical properties and tunable topography have emerged as suitable tools to study cell behavior. Among these materials, synthetic cell interfaces with built-in sensing capabilities are highly advantageous to measure biophysical and biochemical interaction between cells and their environment. In this review, we discuss the design of micro and nanostructured biomaterials engineered not only to mimic the structure, properties, and function of the cellular microenvironment, but also to obtain quantitative information on how cells sense and probe specific adhesive cues from the extracellular domain. This type of responsive biointerfaces provides a readout of mechanics, biochemistry, and electrical activity in real time allowing observation of cellular processes with molecular specificity. Specifically designed sensors based on advanced optical and electrochemical readout are discussed. We further provide an insight into the emerging role of multifunctional micro and nanosensors to control and monitor cell functions by means of material design.
Collapse
Affiliation(s)
- Nicolás Andrés Saffioti
- Instituto de Nanosistemas, Universidad Nacional de General San Martín, San Martín, Argentina
| | | | - Diego Pallarola
- Instituto de Nanosistemas, Universidad Nacional de General San Martín, San Martín, Argentina
| |
Collapse
|
3
|
Kim GH, Kim K, Lee E, An T, Choi W, Lim G, Shin JH. Recent Progress on Microelectrodes in Neural Interfaces. MATERIALS (BASEL, SWITZERLAND) 2018; 11:E1995. [PMID: 30332782 PMCID: PMC6213370 DOI: 10.3390/ma11101995] [Citation(s) in RCA: 63] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/07/2018] [Revised: 10/01/2018] [Accepted: 10/10/2018] [Indexed: 12/31/2022]
Abstract
Brain‒machine interface (BMI) is a promising technology that looks set to contribute to the development of artificial limbs and new input devices by integrating various recent technological advances, including neural electrodes, wireless communication, signal analysis, and robot control. Neural electrodes are a key technological component of BMI, as they can record the rapid and numerous signals emitted by neurons. To receive stable, consistent, and accurate signals, electrodes are designed in accordance with various templates using diverse materials. With the development of microelectromechanical systems (MEMS) technology, electrodes have become more integrated, and their performance has gradually evolved through surface modification and advances in biotechnology. In this paper, we review the development of the extracellular/intracellular type of in vitro microelectrode array (MEA) to investigate neural interface technology and the penetrating/surface (non-penetrating) type of in vivo electrodes. We briefly examine the history and study the recently developed shapes and various uses of the electrode. Also, electrode materials and surface modification techniques are reviewed to measure high-quality neural signals that can be used in BMI.
Collapse
Affiliation(s)
- Geon Hwee Kim
- Department of Mechanical Engineering, Pohang University of Science and Technology, Pohang 37673, Korea.
| | - Kanghyun Kim
- Department of Mechanical Engineering, Pohang University of Science and Technology, Pohang 37673, Korea.
| | - Eunji Lee
- Department of Mechanical Engineering, Pohang University of Science and Technology, Pohang 37673, Korea.
| | - Taechang An
- Department of Mechanical Design Engineering, Andong National University, Kyungbuk 760-749, Korea.
| | - WooSeok Choi
- Department of Mechanical Engineering, Korea National University of Transportation, Chungju 380-702, Korea.
| | - Geunbae Lim
- Department of Mechanical Engineering, Pohang University of Science and Technology, Pohang 37673, Korea.
| | - Jung Hwal Shin
- School of Mechanical Engineering, Kyungnam University, Changwon 51767, Korea.
| |
Collapse
|
4
|
Getz AM, Wijdenes P, Riaz S, Syed NI. Uncovering the Cellular and Molecular Mechanisms of Synapse Formation and Functional Specificity Using Central Neurons of Lymnaea stagnalis. ACS Chem Neurosci 2018. [PMID: 29528213 DOI: 10.1021/acschemneuro.7b00448] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023] Open
Abstract
All functions of the nervous system are contingent upon the precise organization of neuronal connections that are initially patterned during development, and then continually modified throughout life. Determining the mechanisms that specify the formation and functional modulation of synaptic circuitry are critical to advancing both our fundamental understanding of the nervous system as well as the various neurodevelopmental, neurological, neuropsychiatric, and neurodegenerative disorders that are met in clinical practice when these processes go awry. Defining the cellular and molecular mechanisms underlying nervous system development, function, and pathology has proven challenging, due mainly to the complexity of the vertebrate brain. Simple model system approaches with invertebrate preparations, on the other hand, have played pivotal roles in elucidating the fundamental mechanisms underlying the formation and plasticity of individual synapses, and the contributions of individual neurons and their synaptic connections that underlie a variety of behaviors, and learning and memory. In this Review, we discuss the experimental utility of the invertebrate mollusc Lymnaea stagnalis, with a particular emphasis on in vitro cell culture, semi-intact and in vivo preparations, which enable molecular and electrophysiological identification of the cellular and molecular mechanisms governing the formation, plasticity, and specificity of individual synapses at a single-neuron or single-synapse resolution.
Collapse
Affiliation(s)
- Angela M. Getz
- Department of Cell Biology & Anatomy, Hotchkiss Brain Institute and Alberta Children’s Hospital Research Institute, University of Calgary, Calgary, Alberta T2N 1N4, Canada
- Department of Neuroscience, Hotchkiss Brain Institute, University of Calgary, Calgary, Alberta T2N 1N4, Canada
| | - Pierre Wijdenes
- Department of Cell Biology & Anatomy, Hotchkiss Brain Institute and Alberta Children’s Hospital Research Institute, University of Calgary, Calgary, Alberta T2N 1N4, Canada
- Biomedical Engineering Graduate Program, University of Calgary, Calgary, Alberta T2N 1N4, Canada
| | - Saba Riaz
- Department of Cell Biology & Anatomy, Hotchkiss Brain Institute and Alberta Children’s Hospital Research Institute, University of Calgary, Calgary, Alberta T2N 1N4, Canada
| | - Naweed I. Syed
- Department of Cell Biology & Anatomy, Hotchkiss Brain Institute and Alberta Children’s Hospital Research Institute, University of Calgary, Calgary, Alberta T2N 1N4, Canada
| |
Collapse
|
5
|
A Microfluidic Platform for the Characterisation of CNS Active Compounds. Sci Rep 2017; 7:15692. [PMID: 29146949 PMCID: PMC5691080 DOI: 10.1038/s41598-017-15950-0] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2017] [Accepted: 11/03/2017] [Indexed: 01/19/2023] Open
Abstract
New in vitro technologies that assess neuronal excitability and the derived synaptic activity within a controlled microenvironment would be beneficial for the characterisation of compounds proposed to affect central nervous system (CNS) function. Here, a microfluidic system with computer controlled compound perfusion is presented that offers a novel methodology for the pharmacological profiling of CNS acting compounds based on calcium imaging readouts. Using this system, multiple applications of the excitatory amino acid glutamate (10 nM–1 mM) elicited reproducible and reversible transient increases in intracellular calcium, allowing the generation of a concentration response curve. In addition, the system allows pharmacological investigations to be performed as evidenced by application of glutamatergic receptor antagonists, reversibly inhibiting glutamate-induced increases in intracellular calcium. Importantly, repeated glutamate applications elicited significant increases in the synaptically driven activation of the adjacent, environmentally isolated neuronal network. Therefore, the proposed new methodology will enable neuropharmacological analysis of CNS active compounds whilst simultaneously determining their effect on synaptic connectivity.
Collapse
|
6
|
A novel bio-mimicking, planar nano-edge microelectrode enables enhanced long-term neural recording. Sci Rep 2016; 6:34553. [PMID: 27731326 PMCID: PMC5059639 DOI: 10.1038/srep34553] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2016] [Accepted: 09/15/2016] [Indexed: 11/30/2022] Open
Abstract
Our inability to accurately monitor individual neurons and their synaptic activity precludes fundamental understanding of brain function under normal and various pathological conditions. However, recent breakthroughs in micro- and nano-scale fabrication processes have advanced the development of neuro-electronic hybrid technology. Among such devices are three-dimensional and planar electrodes, offering the advantages of either high fidelity or longer-term recordings respectively. Here, we present the next generation of planar microelectrode arrays with “nano-edges” that enable long-term (≥1 month) and high fidelity recordings at a resolution 15 times higher than traditional planar electrodes. This novel technology enables better understanding of brain function and offers a tremendous opportunity towards the development of future bionic hybrids and drug discovery devices.
Collapse
|
7
|
Ghazavi A, Westwick D, Xu F, Wijdenes P, Syed N, Dalton C. Effect of planar microelectrode geometry on neuron stimulation: finite element modeling and experimental validation of the efficient electrode shape. J Neurosci Methods 2015; 248:51-8. [PMID: 25845480 DOI: 10.1016/j.jneumeth.2015.03.024] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2015] [Revised: 03/18/2015] [Accepted: 03/20/2015] [Indexed: 10/23/2022]
Abstract
BACKGROUND Microelectrode arrays have been used successfully for neuronal stimulation both in vivo and in vitro. However, in most instances currents required to activate the neurons have been in un-physiological ranges resulting in neuronal damage and cell death. There is a need to develop electrodes which require less stimulation current for neuronal activation with physiologically relevant efficacy and frequencies. NEW METHOD The objective of the present study was to examine and compare the stimulation efficiency of different electrode geometries at the resolution of a single neuron. We hypothesized that increasing the electrode perimeter will increase the maximum current density at the edges and enhance stimulation efficiency. To test this postulate, the neuronal stimulation efficacy of common circular electrodes (smallest perimeter) was compared with star (medium perimeter), and spiral (largest perimeter with internal boundaries) electrodes. We explored and compared using both a finite element model and in vitro stimulation of neurons isolated from Lymnaea central ganglia. RESULTS Interestingly, both the computational model and the live neuronal stimulation experiments demonstrated that the common circular microelectrode requires less stimulus to activate a cell compared to the other two electrode shapes with the same surface area. Our data further revealed that circular electrodes exhibit the largest sealing resistance, stimulus transfer, and average current density among the three types of electrodes tested. COMPARISON WITH EXISTING METHODS Average current density and not the maximum current density at the edges plays an important role in determining the electrode stimulation efficiency. CONCLUSION Circular shaped electrodes are more efficient in inducing a change in neuronal membrane potential.
Collapse
Affiliation(s)
- Atefeh Ghazavi
- Department of Electrical and Computer Engineering, University of Calgary, Calgary, Alberta T2N 1N4, Canada
| | - David Westwick
- Department of Electrical and Computer Engineering, University of Calgary, Calgary, Alberta T2N 1N4, Canada
| | - Fenglian Xu
- Department of Anatomy and Cell Biology, The Hotchkiss Brain Institute, University of Calgary, Calgary, Alberta T2N 4N1, Canada
| | - Pierre Wijdenes
- Department of Anatomy and Cell Biology, The Hotchkiss Brain Institute, University of Calgary, Calgary, Alberta T2N 4N1, Canada
| | - Naweed Syed
- Department of Anatomy and Cell Biology, The Hotchkiss Brain Institute, University of Calgary, Calgary, Alberta T2N 4N1, Canada
| | - Colin Dalton
- Department of Electrical and Computer Engineering, University of Calgary, Calgary, Alberta T2N 1N4, Canada.
| |
Collapse
|
8
|
Priming and testing silicon patch-clamp neurochips. N Biotechnol 2014; 31:430-5. [PMID: 24780649 DOI: 10.1016/j.nbt.2014.04.003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2013] [Revised: 04/18/2014] [Accepted: 04/19/2014] [Indexed: 10/25/2022]
Abstract
We report on the systematic and automated priming and testing of silicon planar patch-clamp chips after their assembly in Plexiglas packages and sterilization in an air plasma reactor. We find that almost 90% of the chips are successfully primed by our automated setup, and have a shunt capacitance of between 10 pF and 30 pF. Blocked chips are mostly due to glue invasion in the well, and variability in the manual assembly process is responsible for the distribution in shunt capacitance value. Priming and testing time with our automated setup is less than 5 min per chip, which is compatible with the production of large series for use in electrophysiology experiments.
Collapse
|
9
|
Bosca A, Martina M, Py C. Planar patch clamp for neuronal networks--considerations and future perspectives. Methods Mol Biol 2014; 1183:93-113. [PMID: 25023304 DOI: 10.1007/978-1-4939-1096-0_6] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
The patch-clamp technique is generally accepted as the gold standard for studying ion channel activity allowing investigators to either "clamp" membrane voltage and directly measure transmembrane currents through ion channels, or to passively monitor spontaneously occurring intracellular voltage oscillations. However, this resulting high information content comes at a price. The technique is labor-intensive and requires highly trained personnel and expensive equipment. This seriously limits its application as an interrogation tool for drug development. Patch-clamp chips have been developed in the last decade to overcome the tedious manipulations associated with the use of glass pipettes in conventional patch-clamp experiments. In this chapter, we describe some of the main materials and fabrication protocols that have been developed to date for the production of patch-clamp chips. We also present the concept of a patch-clamp chip array providing high resolution patch-clamp recordings from individual cells at multiple sites in a network of communicating neurons. On this chip, the neurons are aligned with the aperture-probes using chemical patterning. In the discussion we review the potential use of this technology for pharmaceutical assays, neuronal physiology and synaptic plasticity studies.
Collapse
Affiliation(s)
- Alessandro Bosca
- Italian Institute of Technology, Via Morego 30, 16163, Genoa, Italy,
| | | | | |
Collapse
|
10
|
Brunello CA, Jokinen V, Sakha P, Terazono H, Nomura F, Kaneko T, Lauri SE, Franssila S, Rivera C, Yasuda K, Huttunen HJ. Microtechnologies to fuel neurobiological research with nanometer precision. J Nanobiotechnology 2013; 11:11. [PMID: 23575365 PMCID: PMC3636074 DOI: 10.1186/1477-3155-11-11] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2013] [Accepted: 04/03/2013] [Indexed: 12/23/2022] Open
Abstract
The interface between engineering and molecular life sciences has been fertile ground for advancing our understanding of complex biological systems. Engineered microstructures offer a diverse toolbox for cellular and molecular biologists to direct the placement of cells and small organisms, and to recreate biological functions in vitro: cells can be positioned and connected in a designed fashion, and connectivity and community effects of cells studied. Because of the highly polar morphology and finely compartmentalized functions of neurons, microfabricated cell culture systems and related on-chip technologies have become an important enabling platform for studying development, function and degeneration of the nervous system at the molecular and cellular level. Here we review some of the compartmentalization techniques developed so far to highlight how high-precision control of neuronal connectivity allows new approaches for studying axonal and synaptic biology.
Collapse
Affiliation(s)
- Cecilia A Brunello
- Neuroscience Center, University of Helsinki, P.O. Box 56, Viikinkaari 4, FI-00014, Helsinki, Finland
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
11
|
Spira ME, Hai A. Multi-electrode array technologies for neuroscience and cardiology. NATURE NANOTECHNOLOGY 2013; 8:83-94. [PMID: 23380931 DOI: 10.1038/nnano.2012.265] [Citation(s) in RCA: 534] [Impact Index Per Article: 48.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/02/2012] [Accepted: 12/18/2012] [Indexed: 05/18/2023]
Abstract
At present, the prime methodology for studying neuronal circuit-connectivity, physiology and pathology under in vitro or in vivo conditions is by using substrate-integrated microelectrode arrays. Although this methodology permits simultaneous, cell-non-invasive, long-term recordings of extracellular field potentials generated by action potentials, it is 'blind' to subthreshold synaptic potentials generated by single cells. On the other hand, intracellular recordings of the full electrophysiological repertoire (subthreshold synaptic potentials, membrane oscillations and action potentials) are, at present, obtained only by sharp or patch microelectrodes. These, however, are limited to single cells at a time and for short durations. Recently a number of laboratories began to merge the advantages of extracellular microelectrode arrays and intracellular microelectrodes. This Review describes the novel approaches, identifying their strengths and limitations from the point of view of the end users--with the intention to help steer the bioengineering efforts towards the needs of brain-circuit research.
Collapse
Affiliation(s)
- Micha E Spira
- The Alexander Silberman Life Sciences Institute, and the Harvey M. Kruger Family Center for Nanoscience, The Hebrew University of Jerusalem, Jerusalem 91904, Israel.
| | | |
Collapse
|
12
|
Py C, Martina M, Monette R, Comas T, Denhoff MW, Luk C, Syed NI, Mealing G. Culturing and electrophysiology of cells on NRCC patch-clamp chips. J Vis Exp 2012:3288. [PMID: 22348948 PMCID: PMC3567197 DOI: 10.3791/3288] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022] Open
Abstract
Due to its exquisite sensitivity and the ability to monitor and control individual cells at the level of ion channels, patch-clamping is the gold standard of electrophysiology applied to disease models and pharmaceutical screens alike. The method traditionally involves gently contacting a cell with a glass pipette filled by a physiological solution in order to isolate a patch of the membrane under its apex. An electrode inserted in the pipette captures ion-channel activity within the membrane patch or, when ruptured, for the whole cell. In the last decade, patch-clamp chips have been proposed as an alternative: a suspended film separates the physiological medium from the culture medium, and an aperture microfabricated in the film replaces the apex of the pipette. Patch-clamp chips have been integrated in automated systems and commercialized for high-throughput screening. To increase throughput, they include the fluidic delivery of cells from suspension, their positioning on the aperture by suction, and automated routines to detect cell-to-probe seals and enter into whole cell mode. We have reported on the fabrication of a silicon patch-clamp chip with optimized impedance and orifice shape that permits the high-quality recording of action potentials in cultured snail neurons; recently, we have also reported progress towards interrogating mammalian neurons. Our patch-clamp chips are fabricated at the Canadian Photonics Fabrication Centre, a commercial foundry, and are available in large series. We are eager to engage in collaborations with electrophysiologists to validate the use of the NRCC technology in different models. The chips are used according to the general scheme represented in Figure 1: the silicon chip is at the bottom of a Plexiglas culture vial and the back of the aperture is connected to a subterranean channel fitted with tubes at either end of the package. Cells are cultured in the vial and the cell on top of the probe is monitored by a measuring electrode inserted in the channel .The two outside fluidic ports facilitate solution exchange with minimal disturbance to the cell; this is an advantage compared to glass pipettes for intracellular perfusion.
Collapse
Affiliation(s)
- Christophe Py
- Institute for Microstructural Sciences, National Research Council of Canada
| | | | | | | | | | | | | | | |
Collapse
|
13
|
Py C, Martina M, Diaz-Quijada GA, Luk CC, Martinez D, Denhoff MW, Charrier A, Comas T, Monette R, Krantis A, Syed NI, Mealing GAR. From understanding cellular function to novel drug discovery: the role of planar patch-clamp array chip technology. Front Pharmacol 2011; 2:51. [PMID: 22007170 PMCID: PMC3184600 DOI: 10.3389/fphar.2011.00051] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2011] [Accepted: 09/05/2011] [Indexed: 11/20/2022] Open
Abstract
All excitable cell functions rely upon ion channels that are embedded in their plasma membrane. Perturbations of ion channel structure or function result in pathologies ranging from cardiac dysfunction to neurodegenerative disorders. Consequently, to understand the functions of excitable cells and to remedy their pathophysiology, it is important to understand the ion channel functions under various experimental conditions - including exposure to novel drug targets. Glass pipette patch-clamp is the state of the art technique to monitor the intrinsic and synaptic properties of neurons. However, this technique is labor intensive and has low data throughput. Planar patch-clamp chips, integrated into automated systems, offer high throughputs but are limited to isolated cells from suspensions, thus limiting their use in modeling physiological function. These chips are therefore not most suitable for studies involving neuronal communication. Multielectrode arrays (MEAs), in contrast, have the ability to monitor network activity by measuring local field potentials from multiple extracellular sites, but specific ion channel activity is challenging to extract from these multiplexed signals. Here we describe a novel planar patch-clamp chip technology that enables the simultaneous high-resolution electrophysiological interrogation of individual neurons at multiple sites in synaptically connected neuronal networks, thereby combining the advantages of MEA and patch-clamp techniques. Each neuron can be probed through an aperture that connects to a dedicated subterranean microfluidic channel. Neurons growing in networks are aligned to the apertures by physisorbed or chemisorbed chemical cues. In this review, we describe the design and fabrication process of these chips, approaches to chemical patterning for cell placement, and present physiological data from cultured neuronal cells.
Collapse
Affiliation(s)
- Christophe Py
- Institute for Microstructural Sciences, National Research Council of CanadaOttawa, ON, Canada
| | - Marzia Martina
- Institute for Biological Sciences, National Research Council of CanadaOttawa, ON, Canada
| | - Gerardo A. Diaz-Quijada
- Steacie Institute for Molecular Sciences, National Research Council of CanadaOttawa, ON, Canada
| | - Collin C. Luk
- Hotchkiss Brain Institute, University of CalgaryCalgary, AB, Canada
| | - Dolores Martinez
- Institute for Microstructural Sciences, National Research Council of CanadaOttawa, ON, Canada
| | - Mike W. Denhoff
- Institute for Microstructural Sciences, National Research Council of CanadaOttawa, ON, Canada
| | - Anne Charrier
- Centre Interdisciplinaire de Nanoscience de Marseille, Centre National de la Recherche ScientifiqueMarseille, France
| | - Tanya Comas
- Institute for Biological Sciences, National Research Council of CanadaOttawa, ON, Canada
| | - Robert Monette
- Institute for Biological Sciences, National Research Council of CanadaOttawa, ON, Canada
| | - Anthony Krantis
- Centre for Research in Biopharmaceuticals and Biotechnology. University of OttawaOttawa, ON, Canada
| | - Naweed I. Syed
- Hotchkiss Brain Institute, University of CalgaryCalgary, AB, Canada
| | - Geoffrey A. R. Mealing
- Institute for Biological Sciences, National Research Council of CanadaOttawa, ON, Canada
| |
Collapse
|