Collins S, Ogilvy A, Hare W, Hilts M, Jirasek A. Iterative image reconstruction algorithm analysis for optical CT radiochromic gel dosimetry. Biomed Phys Eng Express 2024; 10:035031. [PMID: 38579691 DOI: 10.1088/2057-1976/ad3afe] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2023] [Accepted: 04/05/2024] [Indexed: 04/07/2024]
Abstract
Background.Modern radiation therapy technologies aim to enhance radiation dose precision to the tumor and utilize hypofractionated treatment regimens. Verifying the dose distributions associated with these advanced radiation therapy treatments remains an active research area due to the complexity of delivery systems and the lack of suitable three-dimensional dosimetry tools. Gel dosimeters are a potential tool for measuring these complex dose distributions. A prototype tabletop solid-tank fan-beam optical CT scanner for readout of gel dosimeters was recently developed. This scanner does not have a straight raypath from source to detector, thus images cannot be reconstructed using filtered backprojection (FBP) and iterative techniques are required.Purpose.To compare a subset of the top performing algorithms in terms of image quality and quantitatively determine the optimal algorithm while accounting for refraction within the optical CT system. The following algorithms were compared: Landweber, superiorized Landweber with the fast gradient projection perturbation routine (S-LAND-FGP), the fast iterative shrinkage/thresholding algorithm with total variation penalty term (FISTA-TV), a monotone version of FISTA-TV (MFISTA-TV), superiorized conjugate gradient with the nonascending perturbation routine (S-CG-NA), superiorized conjugate gradient with the fast gradient projection perturbation routine (S-CG-FGP), superiorized conjugate gradient with with two iterations of CG performed on the current iterate and the nonascending perturbation routine (S-CG-2-NA).Methods.A ray tracing simulator was developed to track the path of light rays as they traverse the different mediums of the optical CT scanner. Two clinical phantoms and several synthetic phantoms were produced and used to evaluate the reconstruction techniques under known conditions. Reconstructed images were analyzed in terms of spatial resolution, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), signal non-uniformity (SNU), mean relative difference (MRD) and reconstruction time. We developed an image quality based method to find the optimal stopping iteration window for each algorithm. Imaging data from the prototype optical CT scanner was reconstructed and analysed to determine the optimal algorithm for this application.Results.The optimal algorithms found through the quantitative scoring metric were FISTA-TV and S-CG-2-NA. MFISTA-TV was found to behave almost identically to FISTA-TV however MFISTA-TV was unable to resolve some of the synthetic phantoms. S-CG-NA showed extreme fluctuations in the SNR and CNR values. S-CG-FGP had large fluctuations in the SNR and CNR values and the algorithm has less noise reduction than FISTA-TV and worse spatial resolution than S-CG-2-NA. S-LAND-FGP had many of the same characteristics as FISTA-TV; high noise reduction and stability from over iterating. However, S-LAND-FGP has worse SNR, CNR and SNU values as well as longer reconstruction time. S-CG-2-NA has superior spatial resolution to all algorithms while still maintaining good noise reduction and is uniquely stable from over iterating.Conclusions.Both optimal algorithms (FISTA-TV and S-CG-2-NA) are stable from over iterating and have excellent edge detection with ESF MTF 50% values of 1.266 mm-1and 0.992 mm-1. FISTA-TV had the greatest noise reduction with SNR, CNR and SNU values of 424, 434 and 0.91 × 10-4, respectively. However, low spatial resolution makes FISTA-TV only viable for large field dosimetry. S-CG-2-NA has better spatial resolution than FISTA-TV with PSF and LSF MTF 50% values of 1.581 mm-1and 0.738 mm-1, but less noise reduction. S-CG-2-NA still maintains good SNR, CNR, and SNU values of 168, 158 and 1.13 × 10-4, respectively. Thus, S-CG-2-NA is a well rounded reconstruction algorithm that would be the preferable choice for small field dosimetry.
Collapse
Affiliation(s)
- Steve Collins
- Dept. Physics, University of British Columbia-Okanagan, Kelowna, BC, V1V 1V7, Canada
| | - Andy Ogilvy
- Dept. Physics, University of British Columbia-Okanagan, Kelowna, BC, V1V 1V7, Canada
| | - Warren Hare
- Dept. Mathematics, University of British Columbia-Okanagan, Kelowna, BC, V1V 1V7, Canada
| | - Michelle Hilts
- Dept. Physics, University of British Columbia-Okanagan, Kelowna, BC, V1V 1V7, Canada
- Medical Physics, BC Cancer-Kelowna, Kelowna BC V1Y 5L3, Canada
| | - Andrew Jirasek
- Dept. Physics, University of British Columbia-Okanagan, Kelowna, BC, V1V 1V7, Canada
| |
Collapse
|
2
|
Collins S, Ogilvy A, Huang D, Hare W, Hilts M, Jirasek A. Iterative image reconstruction with polar coordinate discretized system matrix for optical CT radiochromic gel dosimetry. Med Phys 2023; 50:6334-6353. [PMID: 37190786 DOI: 10.1002/mp.16459] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2022] [Revised: 03/30/2023] [Accepted: 04/16/2023] [Indexed: 05/17/2023] Open
Abstract
BACKGROUND Gel dosimeters are a potential tool for measuring the complex dose distributions that characterize modern radiotherapy. A prototype tabletop solid-tank fan-beam optical CT scanner for readout of gel dosimeters was recently developed. This scanner does not have a straight raypath from source to detector, thus images cannot be reconstructed using filtered backprojection (FBP) and iterative techniques are required. Iterative image reconstruction requires a system matrix that describes the geometry of the imaging system. Stored system matrices can become immensely large, making them impractical for storage on a typical desktop computer. PURPOSE Here we develop a method to reduce the storage size of optical CT system matrices through use of polar coordinate discretization while accounting for the refraction in optical CT systems. METHODS A ray tracing simulator was developed to track the path of light rays as they traverse the different mediums of the optical CT scanner. Cartesian coordinate discretized system matrices (CCDSMs) and polar coordinate discretized system matrices (PCDSMs) were generated by discretizing the reconstruction area of the optical CT scanner into a Cartesian pixel grid and a polar coordinate pixel grid, respectively. The length of each ray through each pixel was calculated and used to populate the system matrices. To ensure equal weighting during iterative reconstruction, the radial rings of PCDSMs were asymmetrically spaced such that the area of each polar pixel was constant. Two clinical phantoms and several synthetic phantoms were produced and used to evaluate the reconstruction techniques under known conditions. Reconstructed images were analyzed in terms of spatial resolution, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), signal nonuniformity (SNU), and Gamma map pass percentage. RESULTS A storage size reduction of 99.72% was found when comparing a PCDSM to a CCDSM with the same total number of pixels. Images reconstructed with a PCDSM were found to have superior SNR, CNR, SNU, and Gamma (1 mm, 1%) pass percentage compared to those reconstructed with a CCDSM. Increasing spatial resolution in the radial direction with increasing radial distance was found in both PCDSM and CCDSM reconstructions due to the outer regions refracting light more severely. Images reconstructed with a PCDSM showed a decrease in spatial resolution in the azimuthal directions as radial distance increases, due to the widening of the polar pixels. However, this can be mitigated with only a slight increase in storage size by increasing the number of projections. A loss of spatial resolution in the radial direction within 5 mm radially from center was found when reconstructing with a PCDSM, due to the large innermost pixels. However, this was remedied by increasing the number of radial rings within the PCDSM, yielding radial spatial resolution on par with images reconstructed with a CCDSM and a storage size reduction of 99.26%. CONCLUSIONS Discretizing the image pixel elements in polar coordinates achieved a system matrix storage size reduction of 99.26% with only minimal reduction in the image quality.
Collapse
Affiliation(s)
- Steve Collins
- Department of Physics, University of British Columbia-Okanagan, Kelowna, British Columbia, Canada
| | - Andy Ogilvy
- Department of Physics, University of British Columbia-Okanagan, Kelowna, British Columbia, Canada
| | - Dominic Huang
- Department of Mathematics, University of British Columbia-Okanagan, Kelowna, British Columbia, Canada
| | - Warren Hare
- Department of Mathematics, University of British Columbia-Okanagan, Kelowna, British Columbia, Canada
| | - Michelle Hilts
- Department of Physics, University of British Columbia-Okanagan, Kelowna, British Columbia, Canada
- Medical Physics, BC Cancer-Kelowna, Kelowna, British Columbia, Canada
| | - Andrew Jirasek
- Department of Physics, University of British Columbia-Okanagan, Kelowna, British Columbia, Canada
| |
Collapse
|
3
|
Jensen MB, B. Valdetaro L, Balling P, Skyt PS, Petersen JBB, Doran SJ, Sitarz MK, Muren LP. Impact of curing conditions on basic dosimetric properties of silicone-based radiochromic dosimeters for photon and proton irradiation. Acta Oncol 2022; 61:264-268. [PMID: 35037549 DOI: 10.1080/0284186x.2021.2022203] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022]
Affiliation(s)
- Morten B. Jensen
- Danish Centre for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark
- Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
- Department of Medical Physics, Aarhus University Hospital, Aarhus, Denmark
| | - Lia B. Valdetaro
- Danish Centre for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark
- Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| | - Peter Balling
- Department of Physics and Astronomy, Aarhus University, Aarhus, Denmark
- Interdisciplinary Nanoscience Center, Aarhus University, Aarhus, Denmark
| | - Peter S. Skyt
- Danish Centre for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark
| | | | | | - Mateusz K. Sitarz
- Danish Centre for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark
| | - Ludvig P. Muren
- Danish Centre for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark
- Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| |
Collapse
|
4
|
|
5
|
Ba Sunbul N, Oraiqat I, Rosen B, Miller C, Meert C, Matuszak MM, Clarke S, Pozzi S, Moran JM, El Naqa I. Application of radiochromic gel dosimetry to commissioning of a megavoltage research linear accelerator for small-field animal irradiation studies. Med Phys 2021; 48:1404-1416. [PMID: 33378092 DOI: 10.1002/mp.14685] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2020] [Revised: 11/25/2020] [Accepted: 12/17/2020] [Indexed: 11/07/2022] Open
Abstract
PURPOSE To develop and implement an efficient and accurate commissioning procedure for small-field static beam animal irradiation studies on an MV research linear accelerator (Linatron-M9) using radiochromic gel dosimetry. MATERIALS The research linear accelerator (Linatron-M9) is a 9 MV linac with a static fixed collimator opening of 5.08 cm diameter. Lead collimators were manually placed to create smaller fields of 2 × 2 cm2 , 1 × 1 cm2 , and 0.5 × 0.5 cm2 . Relative dosimetry measurements were performed, including profiles, percent depth dose (PDD) curves, beam divergence, and relative output factors using various dosimetry tools, including a small volume ionization chamber (A14), GAFCHROMIC™ EBT3 film, and Clearview gel dosimeters. The gel dosimeter was used to provide a 3D volumetric reference of the irradiated fields. The Linatron profiles and relative output factors were extracted at a reference depth of 2 cm with the output factor measured relative to the 2 × 2 cm2 reference field. Absolute dosimetry was performed using A14 ionization chamber measurements, which were verified using a national standards laboratory remote dosimetry service. RESULTS Absolute dosimetry measurements were confirmed within 1.4% (k = 2, 95% confidence = 5%). The relative output factor of the small fields measured with films and gels agreed with a maximum relative percent error difference between the two methods of 1.1 % for the 1 × 1 cm2 field and 4.3 % for the 0.5 × 0.5 cm2 field. These relative errors were primarily due to the variability in the collimator positioning. The measured beam profiles demonstrated excellent agreement for beam size (measured as FWHM), within approximately 0.8 mm (or less). Film measurements were more accurate in the penumbra region due to the film's finer resolution compared with the gel dosimeter. Following the van Dyk criteria, the PDD values of the film and gel measurements agree within 11% in the buildup region starting from 0.5 cm depth and within 2.6 % beyond maximum dose and into the fall-off region for depths up to 5 cm. The 2D beam profile isodose lines agree within 0.5 mm in all regions for the 0.5 × 0.5 cm2 and the 1 × 1 cm2 fields and within 1 mm for the larger field of 2 × 2 cm2 . The 2D PDD curves agree within approximately 2% of the maximum in the typical therapy region (1-4 cm) for the 1 × 1 cm2 and 2 × 2 cm2 and within 5% for the 0.5 × 0.5 cm2 field. CONCLUSION This work provides a commissioning process to measure the beam characteristics of a fixed beam MV accelerator with detailed dosimetric evaluation for its implementation in megavoltage small animal irradiation studies. Radiochromic gel dosimeters are efficient small-field relative dosimetry tools providing 3D dose measurements allowing for full representation of dose, dosimeter misalignment corrections and high reproducibility with low inter-dosimeter variability. Overall, radiochromic gels are valuable for fast, full relative dosimetry commissioning in comparison to films for application in high-energy small-field animal irradiation studies.
Collapse
Affiliation(s)
- Noora Ba Sunbul
- Department of Nuclear Engineering and Radiological Sciences, University of Michigan, Ann Arbor, MI, USA.,Department of Radiation Oncology, University of Michigan, Ann Arbor, MI, USA
| | - Ibrahim Oraiqat
- Department of Radiation Oncology, University of Michigan, Ann Arbor, MI, USA.,H. Lee Moffitt Cancer Center and Research Institute, Tampa, FL, 33612, USA
| | - Benjamin Rosen
- Department of Radiation Oncology, University of Michigan, Ann Arbor, MI, USA
| | - Cameron Miller
- Department of Nuclear Engineering and Radiological Sciences, University of Michigan, Ann Arbor, MI, USA
| | - Christopher Meert
- Department of Nuclear Engineering and Radiological Sciences, University of Michigan, Ann Arbor, MI, USA
| | - Martha M Matuszak
- Department of Nuclear Engineering and Radiological Sciences, University of Michigan, Ann Arbor, MI, USA.,Department of Radiation Oncology, University of Michigan, Ann Arbor, MI, USA
| | - Shaun Clarke
- Department of Nuclear Engineering and Radiological Sciences, University of Michigan, Ann Arbor, MI, USA
| | - Sara Pozzi
- Department of Nuclear Engineering and Radiological Sciences, University of Michigan, Ann Arbor, MI, USA
| | - Jean M Moran
- Department of Radiation Oncology, University of Michigan, Ann Arbor, MI, USA
| | - Issam El Naqa
- Department of Radiation Oncology, University of Michigan, Ann Arbor, MI, USA.,H. Lee Moffitt Cancer Center and Research Institute, Tampa, FL, 33612, USA
| |
Collapse
|
6
|
Costa F, Doran SJ, Hanson IM, Adamovics J, Nill S, Oelfke U. Edge effects in 3D dosimetry: characterisation and correction of the non-uniform dose response of PRESAGE ®. Phys Med Biol 2020; 65:095003. [PMID: 32143198 DOI: 10.1088/1361-6560/ab7d52] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Previous work has shown that PRESAGE® can be used successfully to perform 3D dosimetric measurements of complex radiotherapy treatments. However, measurements near the sample edges are known to be difficult to achieve. This is an issue when the doses at air-material interfaces are of interest, for example when investigating the electron return effect (ERE) present in treatments delivered by magnetic resonance (MR)-linac systems. To study this effect, a set of 3.5 cm-diameter cylindrical PRESAGE® samples was uniformly irradiated with multiple dose fractions, using either a conventional linac or an MR-linac. The samples were imaged between fractions using an optical-CT, to read out the corresponding accumulated doses. A calibration between TPS-predicted dose and optical-CT pixel value was determined for individual dosimeters as a function of radial distance from the axis of rotation. This data was used to develop a correction that was applied to four additional samples of PRESAGE® of the same formulation, irradiated with 3D-CRT and IMRT treatment plans, to recover significantly improved 3D measurements of dose. An alternative strategy was also tested, in which the outer surface of the sample was physically removed prior to irradiation. Results show that for the formulation studied here, PRESAGE® samples have a central region that responds uniformly and an edge region of 6-7 mm where there is gradual increase in dosimeter response, rising to an over-response of 24%-36% at the outer boundary. This non-uniform dose response increases in both extent and magnitude over time. Both mitigation strategies investigated were successful. In our four exemplar studies, we show how discrepancies at edges are reduced from 13%-37% of the maximum dose to between 2 and 8%. Quantitative analysis shows that the 3D gamma passing rates rise from 90.4, 69.3, 63.7 and 43.6% to 97.3, 99.9, 96.7 and 98.9% respectively.
Collapse
Affiliation(s)
- F Costa
- Joint Department of Physics, The Institute of Cancer Research and Royal Marsden Hospital and, London SM2 5NG, United Kingdom. Author to whom any correspondence should be addressed
| | | | | | | | | | | |
Collapse
|
7
|
Lazzeri L, Marini A, Cascone MG, d'Errico F. Dosimetric and chemical characteristics of Fricke gels based on PVA matrices cross-linked with glutaraldehyde. Phys Med Biol 2019; 64:085015. [PMID: 30913547 DOI: 10.1088/1361-6560/ab135c] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Fricke gel radiochemical sensors based on various matrices have been studied for decades as 3D dosimeters for radiotherapy. Despite their many appealing features, progressive aging and blurring of the signal have prevented the widespread use of these dosimeters, so far. We have addressed these shortcomings and hereby present our development of a Fricke gel based on a chemically cross-linked PVA matrix. We investigated the influence of several parameters of the polymeric matrix on sensitivity, diffusion coefficient and spontaneous oxidation of the proposed gel dosimeter. Based on these findings, we optimized the gel compositions. Our new gel formulation combines transparency, high sensitivity and simple production method, typical of gels based on natural polymers, with low diffusion coefficient and slow spontaneous oxidation typical of PVA gels made by freezing-thawing.
Collapse
Affiliation(s)
- L Lazzeri
- Department of Civil and Industrial Engineering, University of Pisa, Largo Lucio Lazzarino 1, Pisa, Italy. Luigi Lazzeri and Andrea Marini have contributed equally to this work and should be considered co-first authors
| | | | | | | |
Collapse
|
8
|
Luthjens LH, Yao T, Warman JM. A Polymer-Gel Eye-Phantom for 3D Fluorescent Imaging of Millimetre Radiation Beams. Polymers (Basel) 2018; 10:E1195. [PMID: 30961120 PMCID: PMC6290594 DOI: 10.3390/polym10111195] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2018] [Revised: 10/18/2018] [Accepted: 10/23/2018] [Indexed: 11/23/2022] Open
Abstract
We have filled a 24 mm diameter glass sphere with a transparent polymer-gel that is radio-fluorogenic, i.e., it becomes (permanently) fluorescent when irradiated, with an intensity proportional to the local dose deposited. The gel consists of >99.9% tertiary-butyl acrylate (TBA), pre-polymerized to ~15% conversion, and ~100 ppm maleimido-pyrene (MPy). Its dimensions and physical properties are close to those of the vitreous body of the human eye. We have irradiated the gel with a 3 mm diameter, 200 kVp X-ray beam with a dose rate of ~1 Gy/min. A three-dimensional (3D) (video) view of the beam within the gel has been constructed from tomographic images obtained by scanning the sample through a thin sheet of UV light. To minimize optical artefacts, the cell was immersed in a square tank containing a refractive-index-matching medium. The 20⁻80% penumbra of the beam was determined to be ~0.4 mm. This research was a preparatory investigation of the possibility of using this method to monitor the millimetre diameter proton pencil beams used in ocular radiotherapy.
Collapse
Affiliation(s)
- Leonard H Luthjens
- Delft University of Technology, Faculty of Applied Sciences, Department of Radiation Science and Technology, Section Radiation and Isotopes for Health, Mekelweg 15, 2629 JB Delft, The Netherlands.
| | - Tiantian Yao
- Delft University of Technology, Faculty of Applied Sciences, Department of Radiation Science and Technology, Section Radiation and Isotopes for Health, Mekelweg 15, 2629 JB Delft, The Netherlands.
| | - John M Warman
- Delft University of Technology, Faculty of Applied Sciences, Department of Radiation Science and Technology, Section Radiation and Isotopes for Health, Mekelweg 15, 2629 JB Delft, The Netherlands.
| |
Collapse
|
9
|
Dekker KH, Hazarika R, Silveira MA, Jordan KJ. Fixed, object-specific intensity compensation for cone beam optical CT radiation dosimetry. Phys Med Biol 2018; 63:06NT02. [PMID: 29547397 DOI: 10.1088/1361-6560/aab17f] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Optical cone beam computed tomography (CT) scanning of radiochromic gel dosimeters, using a CCD camera and a low stray light convergent source, provides fast, truly 3D radiation dosimetry with high accuracy. However, a key limiting factor in radiochromic gel dosimetry at large (⩾10 cm diameter) volumes is the initial attenuation of the dosimeters. It is not unusual to observe a 5-10× difference in signal intensity through the dosimeter center versus through the surrounding medium in pre-irradiation images. Thus, all dosimetric information in a typical experiment is measured within the lower 10%-20% of the camera sensor's range, and re-use of gels is often not possible due to a lack of transmission. To counteract this, in this note we describe a simple method to create source compensators by printing on transparent films. This technique, which is easily implemented and inexpensive, is an optical analogue to the bowtie filter in x-ray CT. We present transmission images and solution phantom reconstructions to demonstrate that (1) placing compensators beyond the focal zone of the imaging lens prevents high spatial frequency features of the printed films from generating reconstruction artifacts, and (2) object-specific compensation considerably reduces the range of intensities measured in projection images. This will improve the measurable dose range in optical CT dosimetry, and will enable imaging of larger gel volumes (∼15 cm diameter). Additionally, it should enable re-use of dosimeters by printing a new compensator for a second experiment.
Collapse
Affiliation(s)
- Kurtis H Dekker
- Department of Medical Biophysics, Schulich School of Medicine and Dentistry, The University of Western Ontario, London, Ontario, Canada
| | | | | | | |
Collapse
|
10
|
Lee HJ, Kadbi M, Bosco G, Ibbott GS. Real-time volumetric relative dosimetry for magnetic resonance-image-guided radiation therapy (MR-IGRT). Phys Med Biol 2018; 63:045021. [PMID: 29384731 DOI: 10.1088/1361-6560/aaac22] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
The integration of magnetic resonance imaging (MRI) with linear accelerators (linac) has enabled the use of 3D MR-visible gel dosimeters for real-time verification of volumetric dose distributions. Several iron-based radiochromic 3D gels were created in-house then imaged and irradiated in a pre-clinical 1.5 T-7 MV MR-Linac. MR images were acquired using a range of balanced-fast field echo (b-FFE) sequences during irradiation to assess the contrast and dose response in irradiated regions and to minimize the presence of MR artifacts. Out of four radiochromic 3D gel formulations, the FOX 3D gel was found to provide superior MR contrast in the irradiated regions. The FOX gels responded linearly with respect to real-time dose and the signal remained stable post-irradiation for at least 20 min. The response of the FOX gel also was found to be unaffected by the radiofrequency and gradient fields created by the b-FFE sequence during irradiation. A reusable version of the FOX gel was used for b-FFE sequence optimization to reduce artifacts by increasing the number of averages at the expense of temporal resolution. Regardless of the real-time MR sequence used, the FOX 3D gels responded linearly to dose with minimal magnetic field effects due to the strong 1.5 T field or gradient fields present during imaging. These gels can easily be made in-house using non-reusable and reusable formulations depending on the needs of the clinic, and the results of this study encourage further applications of 3D gels for MR-IGRT applications.
Collapse
Affiliation(s)
- Hannah J Lee
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX, United States of America. The University of Texas MD Anderson Cancer Center UTHealth Graduate School of Biomedical Sciences, Houston, TX, United States of America. The University of Texas MD Anderson Cancer Center, 1400 Pressler Street, Houston, TX 77030, United States of America
| | | | | | | |
Collapse
|
11
|
Lee HJ, Roed Y, Venkataraman S, Carroll M, Ibbott GS. Investigation of magnetic field effects on the dose-response of 3D dosimeters for magnetic resonance - image guided radiation therapy applications. Radiother Oncol 2017; 125:426-432. [PMID: 28964533 DOI: 10.1016/j.radonc.2017.08.027] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2017] [Revised: 08/13/2017] [Accepted: 08/29/2017] [Indexed: 10/18/2022]
Abstract
BACKGROUND AND PURPOSE The strong magnetic field of integrated magnetic resonance imaging (MRI) and radiation treatment systems influences secondary electrons resulting in changes in dose deposition in three dimensions. To fill the need for volumetric dose quality assurance, we investigated the effects of strong magnetic fields on 3D dosimeters for MR-image-guided radiation therapy (MR-IGRT) applications. MATERIAL AND METHODS There are currently three main categories of 3D dosimeters, and the following were used in this study: radiochromic plastic (PRESAGE®), radiochromic gel (FOX), and polymer gel (BANG™). For the purposes of batch consistency, an electromagnet was used for same-day irradiations with and without a strong magnetic field (B0, 1.5T for PRESAGE® and FOX and 1.0T for BANG™). RESULTS For PRESAGE®, the percent difference in optical signal with and without B0 was 1.5% at the spectral peak of 632nm. For FOX, the optical signal percent difference was 1.6% at 440nm and 0.5% at 585nm. For BANG™, the percent difference in R2 MR signal was 0.7%. CONCLUSIONS The percent differences in responses with and without strong magnetic fields were minimal for all three 3D dosimeter systems. These 3D dosimeters therefore can be applied to MR-IGRT without requiring a correction factor.
Collapse
Affiliation(s)
- Hannah J Lee
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, USA; The University of Texas MD Anderson Cancer Center UTHealth Graduate School of Biomedical Sciences, USA.
| | - Yvonne Roed
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, USA; Department of Physics, University of Houston, USA
| | - Sara Venkataraman
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, USA
| | - Mitchell Carroll
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, USA; The University of Texas MD Anderson Cancer Center UTHealth Graduate School of Biomedical Sciences, USA
| | - Geoffrey S Ibbott
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, USA.
| |
Collapse
|
12
|
Yao T, Gasparini A, De Haas MP, Luthjens LH, Denkova AG, Warman JM. A tomographic UV-sheet scanning technique for producing 3D fluorescence images of x-ray beams in a radio-fluorogenic gel. Biomed Phys Eng Express 2017. [DOI: 10.1088/2057-1976/aa684b] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
13
|
Dekker KH, Battista JJ, Jordan KJ. Scanning laser optical computed tomography system for large volume 3D dosimetry. Phys Med Biol 2017; 62:2636-2657. [DOI: 10.1088/1361-6560/aa5e9c] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
14
|
Dekker KH, Battista JJ, Jordan KJ. Optical CT imaging of solid radiochromic dosimeters in mismatched refractive index solutions using a scanning laser and large area detector. Med Phys 2016; 43:4585. [DOI: 10.1118/1.4957308] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|