1
|
Schulz E, Woollam M, Vashistha S, Agarwal M. Quantifying exhaled acetone and isoprene through solid phase microextraction and gas chromatography-mass spectrometry. Anal Chim Acta 2024; 1301:342468. [PMID: 38553125 DOI: 10.1016/j.aca.2024.342468] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2023] [Revised: 03/04/2024] [Accepted: 03/11/2024] [Indexed: 04/02/2024]
Abstract
BACKGROUND Acetone, isoprene, and other volatile organic compounds (VOCs) in exhaled breath have been shown to be biomarkers for many medical conditions. Researchers use different techniques for VOC detection, including solid phase microextraction (SPME), to preconcentrate volatile analytes prior to instrumental analysis by gas chromatography-mass spectrometry (GC-MS). These techniques include a previously developed method to detect VOCs in breath directly using SPME, but it is uncommon for studies to quantify exhaled volatiles because it can be time consuming due to the need of many external/internal standards, and there is no standardized or widely accepted method. The objective of this study was to develop an accessible method to quantify acetone and isoprene in breath by SPME GC-MS. RESULTS A system was developed to mimic human exhalation and expose VOCs to a SPME fiber in the gas phase at known concentrations. VOCs were bubbled/diluted with dry air at a fixed flow rate, duration, and volume that was comparable to a previously developed breath sampling method. Identification of acetone and isoprene through GC-MS was verified using standards and observing overlaps in chromatographic retention/mass spectral fragmentation. Calibration curves were developed for these two analytes, which showed a high degree of linear correlation. Acetone and isoprene displayed limits of detection/quantification equal to 12 ppb/37 ppb and 73 ppb/222 ppb respectively. Quantification results in healthy breath samples (n = 15) showed acetone concentrations spanned between 71 ppb and 294 ppb, and isoprene varied between 170 ppb and 990 ppb. Both concentration ranges for acetone and isoprene in this study overlap with those reported in existing literature. SIGNIFICANCE Results indicate the development of a system to quantify acetone and isoprene in breath that can be adapted to diverse sampling methods and instrumental analyses beyond SPME GC-MS.
Collapse
Affiliation(s)
- Eray Schulz
- Integrated Nanosystems Development Institute, Indiana University-Purdue University, Indianapolis, IN, 46202, USA; Department of Chemistry and Chemical Biology, Indiana University-Purdue University, Indianapolis, IN, 46202, USA
| | - Mark Woollam
- Integrated Nanosystems Development Institute, Indiana University-Purdue University, Indianapolis, IN, 46202, USA; Department of Chemistry and Chemical Biology, Indiana University-Purdue University, Indianapolis, IN, 46202, USA
| | - Sneha Vashistha
- Integrated Nanosystems Development Institute, Indiana University-Purdue University, Indianapolis, IN, 46202, USA
| | - Mangilal Agarwal
- Integrated Nanosystems Development Institute, Indiana University-Purdue University, Indianapolis, IN, 46202, USA; Department of Chemistry and Chemical Biology, Indiana University-Purdue University, Indianapolis, IN, 46202, USA; Department of BioHealth Informatics, Indiana University-Purdue University, Indianapolis, IN, 46202, USA.
| |
Collapse
|
2
|
Hlavatsch M, Teuber A, Eisele M, Mizaikoff B. Sensing Liquid- and Gas-Phase Hydrocarbons via Mid-Infrared Broadband Femtosecond Laser Source Spectroscopy. ACS MEASUREMENT SCIENCE AU 2023; 3:452-458. [PMID: 38145022 PMCID: PMC10740123 DOI: 10.1021/acsmeasuresciau.3c00026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/21/2023] [Revised: 09/04/2023] [Accepted: 09/05/2023] [Indexed: 12/26/2023]
Abstract
In this study, we demonstrate the combination of a tunable broadband mid-infrared (MIR) femtosecond laser source separately coupled to a ZnSe crystal horizontal attenuated total reflection (ATR) sensor cell for liquid phase samples and to a substrate-integrated hollow waveguide (iHWG) for gas phase samples. Utilizing this emerging light source technology as an alternative MIR radiation source for Fourier transform infrared (FTIR) spectroscopy opens interesting opportunities for analytical applications. In a first approach, we demonstrate the quantitative analysis of three individual samples, ethanol (liquid), methane (gas), and 2-methyl-1-propene (gas), with limits of detection of 0.3% (ethanol) and 22 ppmv and 74 ppmv (methane and isobutylene), respectively, determined at selected emission wavelengths of the MIR laser source (i.e., 890 cm-1, 1046 and 1305 cm-1). Hence, the applicability of a broadband MIR femtosecond laser source as a bright alternative light source for quantitative analysis via FTIR spectroscopy in various sensing configurations has been demonstrated.
Collapse
Affiliation(s)
- Michael Hlavatsch
- Institute
of Analytical and Bioanalytical Chemistry, Ulm University, Albert-Einstein-Allee 11, D-89081 Ulm, Germany
| | - Andrea Teuber
- Institute
of Analytical and Bioanalytical Chemistry, Ulm University, Albert-Einstein-Allee 11, D-89081 Ulm, Germany
| | - Max Eisele
- TOPTICA
Photonics AG, Lochhamer Schlag 19, D-82166 Graefelfing (Munich), Germany
| | - Boris Mizaikoff
- Institute
of Analytical and Bioanalytical Chemistry, Ulm University, Albert-Einstein-Allee 11, D-89081 Ulm, Germany
- Hahn-Schickard, Sedanstraße
4, D-89077 Ulm, Germany
| |
Collapse
|
3
|
Lv S, Gu T, Wang J, Pan S, Liu F, Sun P, Wang L, Lu G. Pattern Recognition with Temperature Regulation: A Single YSZ-Based Mixed Potential Sensor Classifies Multiple Mixtures of Isoprene, n-Propanol, and Acetone. ACS Sens 2023; 8:4323-4333. [PMID: 37874741 DOI: 10.1021/acssensors.3c01698] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2023]
Abstract
Gas sensors integrated with machine learning algorithms have aroused keen interest in pattern recognition, which ameliorates the drawback of poor selectivity on a sensor. Among various kinds of gas sensors, the yttria-stabilized zirconia (YSZ)-based mixed potential-type sensor possesses advantages of low cost, simple structure, high sensitivity, and superior stability. However, as the number of sensors increases, the increased power consumption and more complicated integration technology may impede their extensive application. Herein, we focus on the development of a single YSZ-based mixed potential sensor from sensing material to machine learning for effective detection and discrimination of unary, binary, and ternary gas mixtures. The sensor that is sensitive to isoprene, n-propanol, and acetone is manufactured with the MgSb2O6 sensing electrode prepared by a simple sol-gel method. Unique response patterns for specific gas mixtures could be generated with temperature regulation. We chose seven algorithm models to be separately trained for discrimination. In order to realize more accurate discrimination, we further discuss the selection of suitable feature parameters and its reasons. With temperature regulation coefficients which are easily available as feature input to model, a single sensor is verified to achieve elevated accuracy rates of 95 and 99% for the discrimination of seven gases (three unary gases, three binary gas mixtures, and one ternary gas mixture) and redefined six gas mixtures. This article provides a potential new approach via a mixed potential sensor instead of a sensor array that could provide a wide application prospect in the field of electronic nose and artificial olfaction.
Collapse
Affiliation(s)
- Siyuan Lv
- State Key Laboratory of Integrated Optoelectronics, Key Laboratory of Advanced Gas Sensors, Jilin Province, College of Electronic Science and Engineering, Jilin University, 2699 Qianjin Street, Changchun 130012, China
| | - Tianyi Gu
- State Key Laboratory of Integrated Optoelectronics, Key Laboratory of Advanced Gas Sensors, Jilin Province, College of Electronic Science and Engineering, Jilin University, 2699 Qianjin Street, Changchun 130012, China
| | - Jing Wang
- College of Chemistry, Jilin University, Changchun 130012, P. R. China
- School of Electronic and Information Engineering, Changchun University of Science and Technology, Changchun 130022, China
| | - Si Pan
- State Key Laboratory of Integrated Optoelectronics, Key Laboratory of Advanced Gas Sensors, Jilin Province, College of Electronic Science and Engineering, Jilin University, 2699 Qianjin Street, Changchun 130012, China
| | - Fangmeng Liu
- State Key Laboratory of Integrated Optoelectronics, Key Laboratory of Advanced Gas Sensors, Jilin Province, College of Electronic Science and Engineering, Jilin University, 2699 Qianjin Street, Changchun 130012, China
- International Center of Future Science, Jilin University, Changchun 130012, China
| | - Peng Sun
- State Key Laboratory of Integrated Optoelectronics, Key Laboratory of Advanced Gas Sensors, Jilin Province, College of Electronic Science and Engineering, Jilin University, 2699 Qianjin Street, Changchun 130012, China
- International Center of Future Science, Jilin University, Changchun 130012, China
| | - Lijun Wang
- State Key Laboratory of Integrated Optoelectronics, Key Laboratory of Advanced Gas Sensors, Jilin Province, College of Electronic Science and Engineering, Jilin University, 2699 Qianjin Street, Changchun 130012, China
| | - Geyu Lu
- State Key Laboratory of Integrated Optoelectronics, Key Laboratory of Advanced Gas Sensors, Jilin Province, College of Electronic Science and Engineering, Jilin University, 2699 Qianjin Street, Changchun 130012, China
- International Center of Future Science, Jilin University, Changchun 130012, China
| |
Collapse
|
4
|
Li Y, Wei X, Zhou Y, Wang J, You R. Research progress of electronic nose technology in exhaled breath disease analysis. MICROSYSTEMS & NANOENGINEERING 2023; 9:129. [PMID: 37829158 PMCID: PMC10564766 DOI: 10.1038/s41378-023-00594-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/11/2023] [Revised: 08/16/2023] [Accepted: 08/17/2023] [Indexed: 10/14/2023]
Abstract
Exhaled breath analysis has attracted considerable attention as a noninvasive and portable health diagnosis method due to numerous advantages, such as convenience, safety, simplicity, and avoidance of discomfort. Based on many studies, exhaled breath analysis is a promising medical detection technology capable of diagnosing different diseases by analyzing the concentration, type and other characteristics of specific gases. In the existing gas analysis technology, the electronic nose (eNose) analysis method has great advantages of high sensitivity, rapid response, real-time monitoring, ease of use and portability. Herein, this review is intended to provide an overview of the application of human exhaled breath components in disease diagnosis, existing breath testing technologies and the development and research status of electronic nose technology. In the electronic nose technology section, the three aspects of sensors, algorithms and existing systems are summarized in detail. Moreover, the related challenges and limitations involved in the abovementioned technologies are also discussed. Finally, the conclusion and perspective of eNose technology are presented.
Collapse
Affiliation(s)
- Ying Li
- School of Instrument Science and Opto-Electronics Engineering, Beijing Information Science and Technology University, Beijing, 100192 China
- Laboratory of Intelligent Microsystems, Beijing Information Science and Technology University, Beijing, 100192 China
| | - Xiangyang Wei
- School of Instrument Science and Opto-Electronics Engineering, Beijing Information Science and Technology University, Beijing, 100192 China
- Laboratory of Intelligent Microsystems, Beijing Information Science and Technology University, Beijing, 100192 China
| | - Yumeng Zhou
- School of Instrument Science and Opto-Electronics Engineering, Beijing Information Science and Technology University, Beijing, 100192 China
| | - Jing Wang
- School of Electronics and Information Engineering, Changchun University of Science and Technology, Changchun, 130022 China
| | - Rui You
- School of Instrument Science and Opto-Electronics Engineering, Beijing Information Science and Technology University, Beijing, 100192 China
- Laboratory of Intelligent Microsystems, Beijing Information Science and Technology University, Beijing, 100192 China
| |
Collapse
|
5
|
Infrared Spectroscopy–Quo Vadis? APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12157598] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Given the exquisite capability of direct, non-destructive label-free sensing of molecular transitions, IR spectroscopy has become a ubiquitous and versatile analytical tool. IR application scenarios range from industrial manufacturing processes, surveillance tasks and environmental monitoring to elaborate evaluation of (bio)medical samples. Given recent developments in associated fields, IR spectroscopic devices increasingly evolve into reliable and robust tools for quality control purposes, for rapid analysis within at-line, in-line or on-line processes, and even for bed-side monitoring of patient health indicators. With the opportunity to guide light at or within dedicated optical structures, remote sensing as well as high-throughput sensing scenarios are being addressed by appropriate IR methodologies. In the present focused article, selected perspectives on future directions for IR spectroscopic tools and their applications are discussed. These visions are accompanied by a short introduction to the historic development, current trends, and emerging technological opportunities guiding the future path IR spectroscopy may take. Highlighted state-of-the art implementations along with novel concepts enhancing the performance of IR sensors are presented together with cutting-edge developments in related fields that drive IR spectroscopy forward in its role as a versatile analytical technology with a bright past and an even brighter future.
Collapse
|
6
|
Kanjwal MA, Ghaferi AA. Advanced Waveguide Based LOC Biosensors: A Minireview. SENSORS (BASEL, SWITZERLAND) 2022; 22:5443. [PMID: 35891123 PMCID: PMC9323137 DOI: 10.3390/s22145443] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/16/2022] [Revised: 06/28/2022] [Accepted: 07/13/2022] [Indexed: 06/15/2023]
Abstract
This mini review features contemporary advances in mid-infrared (MIR) thin-film waveguide technology and on-chip photonics, promoting high-performance biosensing platforms. Supported by recent developments in MIR thin-film waveguides, it is expected that label-free assimilated MIR sensing platforms will soon supplement the current sensing technologies for biomedical diagnostics. The state-of-the-art shows that various types of waveguide material can be utilized for waveguide spectroscopic measurements in MIR. However, there are challenges to integrating these waveguide platforms with microfluidic/Lab-on-a-Chip (LOC) devices, due to poor light-material interactions. Graphene and its analogs have found many applications in microfluidic-based LOC devices, to address to this issue. Graphene-based materials possess a high conductivity, a large surface-to-volume ratio, a smaller and tunable bandgap, and allow easier sample loading; which is essential for acquiring precise electrochemical information. This work discusses advanced waveguide materials, their advantages, and disease diagnostics with MIR thin-film based waveguides. The incorporation of graphene into waveguides improves the light-graphene interaction, and photonic devices greatly benefit from graphene's strong field-controlled optical response.
Collapse
Affiliation(s)
| | - Amal Al Ghaferi
- Mechanical Engineering Department, Khalifa University, Abu Dhabi 127788, United Arab Emirates;
| |
Collapse
|
7
|
Barreto D, Kokoric V, da Silveira Petruci JF, Mizaikoff B. From Light Pipes to Substrate-Integrated Hollow Waveguides for Gas Sensing: A Review. ACS MEASUREMENT SCIENCE AU 2021; 1:97-109. [PMID: 36785552 PMCID: PMC9836072 DOI: 10.1021/acsmeasuresciau.1c00029] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
Absorption-based spectroscopy in the mid-infrared (MIR) spectral range (i.e., 2.5-25 μm) is an excellent choice for directly sensing trace gas analytes providing discriminatory molecular information due to inherently specific fundamental vibrational, rovibrational, and rotational transitions. Complimentarily, the miniaturization of optical components has aided the utility of optical sensing techniques in a wide variety of application scenarios that demand compact, portable, easy-to-use, and robust analytical platforms yet providing suitable accuracy, sensitivity, and selectivity. While MIR sensing technologies have clearly benefitted from the development of advanced on-chip light sources such as quantum cascade and interband cascade lasers and equally small MIR detectors, less attention has been paid to the development of modular/tailored waveguide technologies reproducibly and reliably interfacing photons with sample molecules in a compact format. In this context, the first generation of a new type of hollow waveguides gas cells-the so-called substrate-integrated hollow waveguides (iHWG)-with unprecedented compact dimensions published by the research team of Mizaikoff and collaborators has led to a paradigm change in optical transducer technology for gas sensors. Features of iHWGs included an adaptable (i.e., designable) well-defined optical path length via the integration of meandered hollow waveguide structures at virtually any desired dimension and geometry into an otherwise planar substrate, a high degree of robustness, compactness, and cost-effectiveness in fabrication. Moreover, only a few hundred microliters of gas samples are required for analysis, resulting in short sample transient times facilitating a real-time monitoring of gaseous species in virtually any concentration range. In this review, we give an overview of recent advancements and achievements since their introduction eight years ago, focusing on the development of iHWG-based mid-infrared sensor technologies. Highlighted applications ranging from clinical diagnostics to environmental and industrial monitoring scenarios will be contrasted by future trends, challenges, and opportunities for the development of next-generation portable optical gas-sensing platforms that take advantage of a modular and tailorable device design.
Collapse
Affiliation(s)
- Diandra
Nunes Barreto
- Institute
of Chemistry, Federal University of Uberlândia, Uberlândia 38400-902, MG, Brazil
| | - Vjekoslav Kokoric
- Institute
for Microanalysis Systems, Hahn-Schickard, Ulm 89077, Germany
| | | | - Boris Mizaikoff
- Institute
for Microanalysis Systems, Hahn-Schickard, Ulm 89077, Germany
- Institute
of Analytical and Bioanalytical Chemistry, Ulm University, Ulm 89081, Germany
- e-mail:
| |
Collapse
|
8
|
Kim C, Raja IS, Lee JM, Lee JH, Kang MS, Lee SH, Oh JW, Han DW. Recent Trends in Exhaled Breath Diagnosis Using an Artificial Olfactory System. BIOSENSORS 2021; 11:337. [PMID: 34562928 PMCID: PMC8467588 DOI: 10.3390/bios11090337] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/05/2021] [Revised: 09/06/2021] [Accepted: 09/10/2021] [Indexed: 12/26/2022]
Abstract
Artificial olfactory systems are needed in various fields that require real-time monitoring, such as healthcare. This review introduces cases of detection of specific volatile organic compounds (VOCs) in a patient's exhaled breath and discusses trends in disease diagnosis technology development using artificial olfactory technology that analyzes exhaled human breath. We briefly introduce algorithms that classify patterns of odors (VOC profiles) and describe artificial olfactory systems based on nanosensors. On the basis of recently published research results, we describe the development trend of artificial olfactory systems based on the pattern-recognition gas sensor array technology and the prospects of application of this technology to disease diagnostic devices. Medical technologies that enable early monitoring of health conditions and early diagnosis of diseases are crucial in modern healthcare. By regularly monitoring health status, diseases can be prevented or treated at an early stage, thus increasing the human survival rate and reducing the overall treatment costs. This review introduces several promising technical fields with the aim of developing technologies that can monitor health conditions and diagnose diseases early by analyzing exhaled human breath in real time.
Collapse
Affiliation(s)
- Chuntae Kim
- BIO-IT Foundry Technology Institute, Pusan National University, Busan 46241, Korea
| | | | - Jong-Min Lee
- School of Nano Convergence Technology, Hallym University, Chuncheon 24252, Korea
| | | | - Moon Sung Kang
- Department of Cogno-Mechatronics Engineering, Pusan National University, Busan 46241, Korea
| | - Seok Hyun Lee
- Department of Cogno-Mechatronics Engineering, Pusan National University, Busan 46241, Korea
| | - Jin-Woo Oh
- BIO-IT Foundry Technology Institute, Pusan National University, Busan 46241, Korea
- Department of Nanoenergy Engineering, Pusan National University, Busan 46241, Korea
| | - Dong-Wook Han
- BIO-IT Foundry Technology Institute, Pusan National University, Busan 46241, Korea
- Department of Cogno-Mechatronics Engineering, Pusan National University, Busan 46241, Korea
| |
Collapse
|
9
|
Banik GD, Mizaikoff B. Exhaled breath analysis using cavity-enhanced optical techniques: a review. J Breath Res 2020; 14:043001. [PMID: 32969348 DOI: 10.1088/1752-7163/abaf07] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Cavity-enhanced absorption spectroscopies (CEAS) have gained importance in a wide range of applications in molecular spectroscopy. The development of optical sensors based on the CEAS techniques coupled with the continuous wave or pulsed laser sources operating in the mid-infrared or near-infrared spectral regime uniquely offers molecularly selective and ultra-sensitive detection of trace species in complex matrices including exhaled human breath. In this review, we discussed recent applications of CEAS for analyzing trace constituents within the exhaled breath matrix facilitating the non-invasive assessment of human health status. Next to a brief discussion on the mechanisms of formation of trace components found in the exhaled breath matrix related to particular disease states, existing challenges in CEAS and future development towards non-invasive clinical diagnostics will be discussed.
Collapse
Affiliation(s)
- Gourab D Banik
- Institute of Analytical and Bioanalytical Chemistry, Ulm University Albert-Einstein-Allee 11, 89081 Ulm, Germany
| | | |
Collapse
|
10
|
Selvaraj R, Vasa NJ, Nagendra SMS, Mizaikoff B. Advances in Mid-Infrared Spectroscopy-Based Sensing Techniques for Exhaled Breath Diagnostics. Molecules 2020; 25:molecules25092227. [PMID: 32397389 PMCID: PMC7249025 DOI: 10.3390/molecules25092227] [Citation(s) in RCA: 30] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2020] [Revised: 04/28/2020] [Accepted: 04/29/2020] [Indexed: 01/05/2023] Open
Abstract
Human exhaled breath consists of more than 3000 volatile organic compounds, many of which are relevant biomarkers for various diseases. Although gas chromatography has been the gold standard for volatile organic compound (VOC) detection in exhaled breath, recent developments in mid-infrared (MIR) laser spectroscopy have led to the promise of compact point-of-care (POC) optical instruments enabling even single breath diagnostics. In this review, we discuss the evolution of MIR sensing technologies with a special focus on photoacoustic spectroscopy, and its application in exhaled breath biomarker detection. While mid-infrared point-of-care instrumentation promises high sensitivity and inherent molecular selectivity, the lack of standardization of the various techniques has to be overcome for translating these techniques into more widespread real-time clinical use.
Collapse
Affiliation(s)
- Ramya Selvaraj
- Department of Engineering Design, Indian Institute of Technology Madras, Chennai 600036, India;
- Correspondence:
| | - Nilesh J. Vasa
- Department of Engineering Design, Indian Institute of Technology Madras, Chennai 600036, India;
| | - S. M. Shiva Nagendra
- Department of Civil Engineering, Indian Institute of Technology Madras, Chennai 600036, India;
| | - Boris Mizaikoff
- Institute of Analytical and Bioanalytical Chemistry, Ulm University, 89081 Ulm, Germany;
| |
Collapse
|
11
|
Glöckler J, Jaeschke C, Kocaöz Y, Kokoric V, Tütüncü E, Mitrovics J, Mizaikoff B. iHWG-MOX: A Hybrid Breath Analysis System via the Combination of Substrate-Integrated Hollow Waveguide Infrared Spectroscopy with Metal Oxide Gas Sensors. ACS Sens 2020; 5:1033-1039. [PMID: 32189494 DOI: 10.1021/acssensors.9b02554] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
According to their materials and operating parameters, metal oxide (MOX) sensors respond to target gases only by a change in sensor resistance with a lack in selectivity. By the use of infrared spectroscopy, highly discriminatory information from samples at a molecular level can be obtained and the selectivity can be enhanced. A low-volume gas cell was developed for a commercially available semiconducting MOX methane gas sensor and coupled directly to a mid-infrared gas sensor based on substrate-integrated hollow waveguide (iHWG) technology combined with a Fourier transform infrared spectrometer. This study demonstrates a sensing process with combined orthogonal sensors for fast, time-resolved, and synergic detection of methane and carbon dioxide in gas samples.
Collapse
Affiliation(s)
- Johannes Glöckler
- Institute of Analytical and Bioanalytical Chemistry, Ulm University, Albert-Einstein-Allee 11, 89081 Ulm, Germany
| | - Carsten Jaeschke
- Institute of Analytical and Bioanalytical Chemistry, Ulm University, Albert-Einstein-Allee 11, 89081 Ulm, Germany
- JLM Innovation GmbH, Vor dem Kreuzberg 17, 72070 Tübingen, Germany
| | - Yusuf Kocaöz
- Institute of Analytical and Bioanalytical Chemistry, Ulm University, Albert-Einstein-Allee 11, 89081 Ulm, Germany
| | - Vjekoslav Kokoric
- Institute of Analytical and Bioanalytical Chemistry, Ulm University, Albert-Einstein-Allee 11, 89081 Ulm, Germany
| | - Erhan Tütüncü
- Institute of Analytical and Bioanalytical Chemistry, Ulm University, Albert-Einstein-Allee 11, 89081 Ulm, Germany
| | - Jan Mitrovics
- JLM Innovation GmbH, Vor dem Kreuzberg 17, 72070 Tübingen, Germany
| | - Boris Mizaikoff
- Institute of Analytical and Bioanalytical Chemistry, Ulm University, Albert-Einstein-Allee 11, 89081 Ulm, Germany
| |
Collapse
|
12
|
Hagemann LT, Ehrle S, Mizaikoff B. Optimizing the Analytical Performance of Substrate-Integrated Hollow Waveguides: Experiment and Simulation. APPLIED SPECTROSCOPY 2019; 73:1451-1460. [PMID: 31397586 DOI: 10.1177/0003702819867342] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
The goal of this technical note was to compare experimentally and via simulation of eight substrate-integrated hollow waveguide (iHWG) designs, and to predict promising future iHWG structures in lieu of experiments. The iHWGs differed in their geometry (i.e., inlet funnel cross-section and inner channel cross-section), as well as in their material properties (i.e., type of metal, polish of inner channel). Experimentally, calibration functions of isobutane as a model analyte were determined, and the analytical figures of merit, i.e., signal-to-noise ratio, limit of detection, were evaluated for each iHWG. Evaluation of the amount of radiation incident at the real-world and simulated detector revealed that experiment and simulation were in excellent agreement. While material and quality of the inner channel wall did not have a significant influence on the performance, the iHWG geometry profoundly affected the performance in terms of light throughput: Increasing the inlet funnel dimensions and the inner channel cross-section benefits light throughout, and thus, the analytical signal. Based on these results, simulations of not yet fabricated iHWGs were performed and promising new iHWG structures were suggested.
Collapse
Affiliation(s)
| | - Sonja Ehrle
- Institute of Analytical and Bioanalytical Chemistry, Ulm, Germany
| | - Boris Mizaikoff
- Institute of Analytical and Bioanalytical Chemistry, Ulm, Germany
| |
Collapse
|
13
|
Khan S, Newport D, Le Calvé S. Gas Detection Using Portable Deep-UV Absorption Spectrophotometry: A Review. SENSORS 2019; 19:s19235210. [PMID: 31795069 PMCID: PMC6929016 DOI: 10.3390/s19235210] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/04/2019] [Revised: 11/19/2019] [Accepted: 11/19/2019] [Indexed: 12/25/2022]
Abstract
Several gas molecules of environmental and domestic significance exhibit a strong deep-UV absorption. Therefore, a sensitive and a selective gas detector based on this unique molecular property (i.e., absorption at a specific wavelength) can be developed using deep-UV absorption spectrophotometry. UV absorption spectrometry provides a highly sensitive, reliable, self-referenced, and selective approach for gas sensing. This review article addresses the recent progress in the application of deep-UV absorption for gas sensing owing to its inherent features and tremendous potentials. Applications, advancements, and challenges related to UV emission sources, gas cells, and UV photodetectors are assessed and compared. We present the relevant theoretical aspects and challenges associated with the development of portable sensitive spectrophotometer. Finally, the applications of UV absorption spectrometry for ozone, NO2, SO2, and aromatic organic compounds during the last decades are discussed and compared. A portable UV absorption spectrophotometer can be developed by using LEDs, hollow core waveguides (HCW), and UV photodetectors (i.e., photodiodes). LED provides a portable UV emission source with low power input, low-intensity drifts, low cost, and ease of alignment. It is a quasi-chromatic UV source and covers the absorption band of molecules without optical filters for absorbance measurement of a target analyte. HCWs can be applied as a miniature gas cell for guiding UV radiation for measurement of low gas concentrations. Photodiodes, on the other hand, offer a portable UV photodetector with excellent spectral selectivity with visible rejection, minimal dark current, linearity, and resistance against UV-aging.
Collapse
Affiliation(s)
- Sulaiman Khan
- School of Engineering, Bernal Institute, University of Limerick, Limerick V94 T9PX, Ireland; (S.K.); (D.N.)
- Université de Strasbourg, CNRS, ICPEES UMR 7515, F-67000 Strasbourg, France
- In’Air Solutions, 67087 Strasbourg, France
| | - David Newport
- School of Engineering, Bernal Institute, University of Limerick, Limerick V94 T9PX, Ireland; (S.K.); (D.N.)
| | - Stéphane Le Calvé
- Université de Strasbourg, CNRS, ICPEES UMR 7515, F-67000 Strasbourg, France
- In’Air Solutions, 67087 Strasbourg, France
- Correspondence:
| |
Collapse
|
14
|
Haas J, Pleyer M, Nauschütz J, Koeth J, Nägele M, Bibikova O, Sakharova T, Artyushenko V, Mizaikoff B. iBEAM: substrate-integrated hollow waveguides for efficient laser beam combining. OPTICS EXPRESS 2019; 27:23059-23066. [PMID: 31510588 DOI: 10.1364/oe.27.023059] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
Laser light sources are routinely applied building blocks in optical sensor technologies. While lasers are emitting at a precisely defined wavelength within narrow emission bands, chem/bio-sensing applications frequently demand multi-wavelength illumination for addressing a series of species. Instead of using broadband radiation sources, it is a viable strategy to efficiently combine the beams emitted from different lasers to maintain the spectral brightness and yet cover extended wavelength regimes. In this study, substrate-integrated hollow waveguides (iHWGs) are reported as a versatile and efficient alternative compared to conventional beam combining concepts, especially for applications in the mid-infrared spectral regime leading to a highly efficient multi-port beam combiner-the iBEAM.
Collapse
|
15
|
Porterfield JP, Westerfield JH, Satterthwaite L, Patterson D, Changala PB, Baraban JH, McCarthy MC. Rotational Characterization of the Elusive gauche-Isoprene. J Phys Chem Lett 2019; 10:1981-1985. [PMID: 30897904 DOI: 10.1021/acs.jpclett.9b00411] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Isoprene (2-methyl-1,3-butadiene) is highly abundant in the atmosphere, second only to methane in hydrocarbon emissions. In contrast to the most stable trans rotamer, structural characterization of gauche-isoprene has proven challenging: it is weakly polar, present at the level of only a few percent at room temperature, and structurally complex due to both torsional and methyl tunneling motions. gauche-Isoprene has been observed by two distinct but complementary experimental approaches: chirped-pulse Fourier transform microwave (CP-FTMW) spectroscopy coupled with cryogenic buffer gas cooling, and cavity-enhanced FTMW spectroscopy with a pulsed discharge source. Thermal enhancement of the gauche population (from 1.7% to 10.3%) was observed in the cryogenic buffer gas cell when the sample was preheated from 300 to 450 K, demonstrating that high-energy rotamers can be efficiently isolated under our experimental conditions. Rotational parameters for the inversion states (0+/0-) have been determined for the first time, aided by calculations at increasing levels of theoretical sophistication. From this combined analysis, the inversion splitting Δ E and the Fbc Coriolis coupling constant between the two inversion states have been derived.
Collapse
Affiliation(s)
- Jessica P Porterfield
- Harvard-Smithsonian Center for Astrophysics , Cambridge , Massachusetts 02138 , United States
| | - J H Westerfield
- Department of Chemistry , New College of Florida , Sarasota , Florida 34243 , United States
| | - Lincoln Satterthwaite
- Department of Physics , University of California , Santa Barbara , California 93106 , United States
| | - David Patterson
- Department of Physics , University of California , Santa Barbara , California 93106 , United States
| | - P Bryan Changala
- Department of Physics , University of Colorado , Boulder , Colorado 80302 , United States
| | - Joshua H Baraban
- Department of Chemistry , Ben-Gurion University of the Negev , Beersheva 84105 , Israel
| | - Michael C McCarthy
- Harvard-Smithsonian Center for Astrophysics , Cambridge , Massachusetts 02138 , United States
| |
Collapse
|
16
|
Cascade laser sensing concepts for advanced breath diagnostics. Anal Bioanal Chem 2018; 411:1679-1686. [PMID: 30565171 DOI: 10.1007/s00216-018-1509-5] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2018] [Revised: 11/12/2018] [Accepted: 11/21/2018] [Indexed: 01/03/2023]
Abstract
With more than a thousand constituents at trace level concentrations, exhaled breath analysis (EBA) allows for non-invasive point-of-care (POC) disease diagnostics and metabolic status monitoring in or close to real-time. A number of biomarkers in breath may be used to not only identify diseases and disease progression but also to monitor therapeutic interventions. Although the relationship of selected breath components/biomarkers with certain disease pathologies is well established, diagnosing the exhaled breath composition remains an analytical and practical challenge due to the concentration levels of molecules of interest, i.e., low parts-per-billion (ppb) regime and below. Besides the analytical assessment of breath components via conventional methods such as gas chromatography coupled to mass spectrometry and related techniques, the application of cascade laser spectroscopy (CLS) is relatively new and exhibits several advantages when aiming for compact and user-friendly trace gas sensors with high molecular selectivity, the required sensitivity, and potentially reasonable instrumental costs. This trend article highlights the current status and potential of CLS in breath diagnostics with a focus on recent advancements in instrumentation and application along with future prospects and challenges. Graphical abstract Cascade laser technology in the mid-infrared spectral range enables sensitive and molecularly selective exhaled breath analysis with near real-time response, label-free detection, and point-of-care feasibility.
Collapse
|
17
|
Wallace MAG, Pleil JD. Evolution of clinical and environmental health applications of exhaled breath research: Review of methods and instrumentation for gas-phase, condensate, and aerosols. Anal Chim Acta 2018; 1024:18-38. [PMID: 29776545 PMCID: PMC6082128 DOI: 10.1016/j.aca.2018.01.069] [Citation(s) in RCA: 60] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2017] [Revised: 01/29/2018] [Accepted: 01/31/2018] [Indexed: 12/20/2022]
Abstract
Human breath, along with urine and blood, has long been one of the three major biological media for assessing human health and environmental exposure. In fact, the detection of odor on human breath, as described by Hippocrates in 400 BC, is considered the first analytical health assessment tool. Although less common in comparison to contemporary bio-fluids analyses, breath has become an attractive diagnostic medium as sampling is non-invasive, unlimited in timing and volume, and does not require clinical personnel. Exhaled breath, exhaled breath condensate (EBC), and exhaled breath aerosol (EBA) are different types of breath matrices used to assess human health and disease state. Over the past 20 years, breath research has made many advances in assessing health state, overcoming many of its initial challenges related to sampling and analysis. The wide variety of sampling techniques and collection devices that have been developed for these media are discussed herein. The different types of sensors and mass spectrometry instruments currently available for breath analysis are evaluated as well as emerging breath research topics, such as cytokines, security and airport surveillance, cellular respiration, and canine olfaction.
Collapse
Affiliation(s)
- M Ariel Geer Wallace
- U.S. Environmental Protection Agency, Office of Research and Development, National Exposure Research Laboratory, 109 T.W. Alexander Drive, Research Triangle Park, NC, 27711, USA.
| | - Joachim D Pleil
- U.S. Environmental Protection Agency, Office of Research and Development, National Exposure Research Laboratory, 109 T.W. Alexander Drive, Research Triangle Park, NC, 27711, USA.
| |
Collapse
|
18
|
Pahlow S, Weber K, Popp J, Wood BR, Kochan K, Rüther A, Perez-Guaita D, Heraud P, Stone N, Dudgeon A, Gardner B, Reddy R, Mayerich D, Bhargava R. Application of Vibrational Spectroscopy and Imaging to Point-of-Care Medicine: A Review. APPLIED SPECTROSCOPY 2018; 72:52-84. [PMID: 30265133 PMCID: PMC6524782 DOI: 10.1177/0003702818791939] [Citation(s) in RCA: 60] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Affiliation(s)
- Susanne Pahlow
- Friedrich Schiller University Jena, Institute of Physical Chemistry and Abbe Center of Photonics, Jena, Germany
- InfectoGnostics Research Campus Jena, Centre for Applied Research, Jena, Germany
| | - Karina Weber
- Friedrich Schiller University Jena, Institute of Physical Chemistry and Abbe Center of Photonics, Jena, Germany
- InfectoGnostics Research Campus Jena, Centre for Applied Research, Jena, Germany
- Leibniz Institute of Photonic Technology-Leibniz Health Technologies, Jena, Germany
| | - Jürgen Popp
- Friedrich Schiller University Jena, Institute of Physical Chemistry and Abbe Center of Photonics, Jena, Germany
- InfectoGnostics Research Campus Jena, Centre for Applied Research, Jena, Germany
- Leibniz Institute of Photonic Technology-Leibniz Health Technologies, Jena, Germany
| | - Bayden R. Wood
- Centre for Biospectroscopy, School of Chemistry, Monash University, Clayton, Victoria, Australia
| | - Kamila Kochan
- Centre for Biospectroscopy, School of Chemistry, Monash University, Clayton, Victoria, Australia
| | - Anja Rüther
- Centre for Biospectroscopy, School of Chemistry, Monash University, Clayton, Victoria, Australia
| | - David Perez-Guaita
- Centre for Biospectroscopy, School of Chemistry, Monash University, Clayton, Victoria, Australia
| | - Philip Heraud
- Centre for Biospectroscopy, School of Chemistry, Monash University, Clayton, Victoria, Australia
| | - Nick Stone
- University of Exeter, School of Physics and Astronomy, Exeter, UK
| | - Alex Dudgeon
- University of Exeter, School of Physics and Astronomy, Exeter, UK
| | - Ben Gardner
- University of Exeter, School of Physics and Astronomy, Exeter, UK
| | - Rohith Reddy
- Department of Electrical Engineering, University of Houston, Houston, USA
| | - David Mayerich
- Department of Electrical Engineering, University of Houston, Houston, USA
| | - Rohit Bhargava
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana Champaign, Departments of Mechanical Engineering, Bioengineering, Chemical and Biomolecular Engineering, Electrical and Computer Engineering, and Chemistry, University of Illinois at Urbana-Champaign, Urbana, USA
| |
Collapse
|
19
|
Seichter F, Tütüncü E, Hagemann LT, Vogt J, Wachter U, Gröger M, Kress S, Radermacher P, Mizaikoff B. Online monitoring of carbon dioxide and oxygen in exhaled mouse breath via substrate-integrated hollow waveguide Fourier-transform infrared-luminescence spectroscopy. J Breath Res 2018; 12:036018. [DOI: 10.1088/1752-7163/aabf98] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
20
|
da Silveira Petruci JF, Wilk A, Cardoso AA, Mizaikoff B. A Hyphenated Preconcentrator-Infrared-Hollow-Waveguide Sensor System for N 2O Sensing. Sci Rep 2018; 8:5909. [PMID: 29650982 PMCID: PMC5897552 DOI: 10.1038/s41598-018-23961-8] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2017] [Accepted: 03/21/2018] [Indexed: 11/09/2022] Open
Abstract
Following the Kyoto protocol, all signatory countries must provide an annual inventory of greenhouse-gas emission including N2O. This fact associated with the wide variety of sources for N2O emissions requires appropriate sensor technologies facilitating in-situ monitoring, compact dimensions, ease of operation, and sufficient sensitivity for addressing such emission scenarios. In this contribution, we therefore describe an innovative portable mid-infrared chemical sensor system for quantifying gaseous N2O via coupling a substrate-integrated hollow waveguide (iHWG) simultaneously serving as highly miniaturized mid-infrared photon conduit and gas cell to a custom-made preconcentrator. N2O was collected onto a solid sorbent material packed into the preconcentrator unit, and then released via thermal desorption into the iHWG-MIR sensor utilizing a compact Fourier transform infrared (FTIR) spectrometer for molecularly selective spectroscopic detection with a limit of detection (LOD) at 5 ppbv. Highlighting the device flexibility in terms of sampling time, flow-rate, and iHWG design facilitates tailoring the developed preconcentrator-iHWG device towards a wide variety of application scenarios ranging from soil and aquatic emission monitoring and drone- or unmanned aerial vehicle (UAV)-mounted monitoring systems to clinical/medical analysis scenarios.
Collapse
Affiliation(s)
- João Flavio da Silveira Petruci
- São Paulo State University, Department of Analytical Chemistry, UNESP, CEP 14800-970, Araraquara, SP, Brazil.,Ulm University, Institute of Analytical and Bioanalytical Chemistry, 89081, Ulm, Germany
| | - Andreas Wilk
- Ulm University, Institute of Analytical and Bioanalytical Chemistry, 89081, Ulm, Germany
| | - Arnaldo Alves Cardoso
- São Paulo State University, Department of Analytical Chemistry, UNESP, CEP 14800-970, Araraquara, SP, Brazil
| | - Boris Mizaikoff
- Ulm University, Institute of Analytical and Bioanalytical Chemistry, 89081, Ulm, Germany.
| |
Collapse
|
21
|
Stach R, Haas J, Tütüncü E, Daboss S, Kranz C, Mizaikoff B. polyHWG: 3D Printed Substrate-Integrated Hollow Waveguides for Mid-Infrared Gas Sensing. ACS Sens 2017; 2:1700-1705. [PMID: 29090579 DOI: 10.1021/acssensors.7b00649] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Gas analysis via mid-infrared (MIR) spectroscopic techniques has gained significance due to its inherent molecular selectivity and sensitivity probing pronounced vibrational, rotational, and roto-vibrational modes. In addition, MIR gas sensors are suitable for real-time monitoring in a wide variety of sensing scenarios. Our research team has recently introduced so-called substrate-integrated hollow waveguides (iHWGs) fabricated by precision milling, which have been demonstrated to be useful in online process monitoring, environmental sensing, and exhaled breath analysis especially if low sample volumes (i.e., few hundreds of microliters) are probed with rapid signal transients. A logical next step is to establish ultralightweight, potentially disposable, and low-cost substrate-integrated hollow waveguides, which may be readily customized and tailored to specific applications using 3D printing techniques. 3D printing provides access to an unprecedented variety of thermoplastic materials including biocompatible polylactides, readily etchable styrene copolymers, and magnetic or conductive materials. Thus, the properties of the waveguide may be adapted to suit its designated application, e.g., drone-mounted ultralightweight waveguides for environmental monitoring or biocompatible disposable sensor interfaces in medical/clinical applications.
Collapse
Affiliation(s)
- Robert Stach
- Institute of Analytical and
Bioanalytical Chemistry, Ulm University, Albert-Einstein-Allee 11, 89081 Ulm, Germany
| | - Julian Haas
- Institute of Analytical and
Bioanalytical Chemistry, Ulm University, Albert-Einstein-Allee 11, 89081 Ulm, Germany
| | - Erhan Tütüncü
- Institute of Analytical and
Bioanalytical Chemistry, Ulm University, Albert-Einstein-Allee 11, 89081 Ulm, Germany
| | - Sven Daboss
- Institute of Analytical and
Bioanalytical Chemistry, Ulm University, Albert-Einstein-Allee 11, 89081 Ulm, Germany
| | - Christine Kranz
- Institute of Analytical and
Bioanalytical Chemistry, Ulm University, Albert-Einstein-Allee 11, 89081 Ulm, Germany
| | - Boris Mizaikoff
- Institute of Analytical and
Bioanalytical Chemistry, Ulm University, Albert-Einstein-Allee 11, 89081 Ulm, Germany
| |
Collapse
|
22
|
Schädle T, Mizaikoff B. Mid-Infrared Waveguides: A Perspective. APPLIED SPECTROSCOPY 2016; 70:1625-1638. [PMID: 27624555 DOI: 10.1177/0003702816659668] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/09/2016] [Accepted: 05/10/2016] [Indexed: 05/28/2023]
Abstract
Significant advancements in waveguide technology in the mid-infrared (MIR) regime during recent decades have assisted in establishing MIR spectroscopic and sensing technologies as a routine tool among nondestructive analytical methods. In this review, the evolution of MIR waveguides along with state-of-the-art technologies facilitating next-generation MIR chem/bio sensors will be discussed introducing a classification scheme defining three "generations" of MIR waveguides: (1) conventional internal reflection elements as "first generation" waveguides; (2) MIR-transparent optical fibers as "second generation" waveguides; and most recently introduced(3) thin-film structures as "third generation" waveguides. Selected application examples for these each waveguide category along with future trends will highlight utility and perspectives for waveguide-based MIR spectroscopy and sensing systems.
Collapse
Affiliation(s)
- Thomas Schädle
- Institute of Analytical and Bioanalytical Chemistry (IABC), Ulm University, Ulm, Germany
| | - Boris Mizaikoff
- Institute of Analytical and Bioanalytical Chemistry (IABC), Ulm University, Ulm, Germany
| |
Collapse
|
23
|
Petruci JFDS, Cardoso AA, Wilk A, Kokoric V, Mizaikoff B. iCONVERT: An Integrated Device for the UV-Assisted Determination of H2S via Mid-Infrared Gas Sensors. Anal Chem 2015; 87:9580-3. [PMID: 26369573 DOI: 10.1021/acs.analchem.5b02731] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- João Flavio da Silveira Petruci
- São Paulo State University, Department of Analytical
Chemistry, UNESP, CEP 14800-970, Araraquara, São Paulo, Brazil
- University of Ulm, Institute of Analytical and Bioanalytical
Chemistry, 89081, Ulm, Germany
| | - Arnaldo Alves Cardoso
- São Paulo State University, Department of Analytical
Chemistry, UNESP, CEP 14800-970, Araraquara, São Paulo, Brazil
| | - Andreas Wilk
- University of Ulm, Institute of Analytical and Bioanalytical
Chemistry, 89081, Ulm, Germany
| | - Vjekoslav Kokoric
- University of Ulm, Institute of Analytical and Bioanalytical
Chemistry, 89081, Ulm, Germany
| | - Boris Mizaikoff
- University of Ulm, Institute of Analytical and Bioanalytical
Chemistry, 89081, Ulm, Germany
| |
Collapse
|
24
|
Petruci JFDS, Wilk A, Cardoso AA, Mizaikoff B. Online Analysis of H2S and SO2 via Advanced Mid-Infrared Gas Sensors. Anal Chem 2015; 87:9605-11. [DOI: 10.1021/acs.analchem.5b02730] [Citation(s) in RCA: 43] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- João Flavio da Silveira Petruci
- São Paulo State University, Department of Analytical
Chemistry, UNESP, CEP 14800-970, Araraquara, São Paulo Brazil
- University of Ulm, Institute of Analytical and Bioanalytical
Chemistry, 89081, Ulm, Germany
| | - Andreas Wilk
- University of Ulm, Institute of Analytical and Bioanalytical
Chemistry, 89081, Ulm, Germany
| | - Arnaldo Alves Cardoso
- São Paulo State University, Department of Analytical
Chemistry, UNESP, CEP 14800-970, Araraquara, São Paulo Brazil
| | - Boris Mizaikoff
- University of Ulm, Institute of Analytical and Bioanalytical
Chemistry, 89081, Ulm, Germany
| |
Collapse
|
25
|
Mochalski P, Unterkofler K, Teschl G, Amann A. Potential of volatile organic compounds as markers of entrapped humans for use in urban search-and-rescue operations. Trends Analyt Chem 2015. [DOI: 10.1016/j.trac.2015.02.013] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
|
26
|
Mathew TL, Pownraj P, Abdulla S, Pullithadathil B. Technologies for Clinical Diagnosis Using Expired Human Breath Analysis. Diagnostics (Basel) 2015; 5:27-60. [PMID: 26854142 PMCID: PMC4665550 DOI: 10.3390/diagnostics5010027] [Citation(s) in RCA: 76] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2014] [Revised: 10/20/2014] [Accepted: 12/01/2014] [Indexed: 12/24/2022] Open
Abstract
This review elucidates the technologies in the field of exhaled breath analysis. Exhaled breath gas analysis offers an inexpensive, noninvasive and rapid method for detecting a large number of compounds under various conditions for health and disease states. There are various techniques to analyze some exhaled breath gases, including spectrometry, gas chromatography and spectroscopy. This review places emphasis on some of the critical biomarkers present in exhaled human breath, and its related effects. Additionally, various medical monitoring techniques used for breath analysis have been discussed. It also includes the current scenario of breath analysis with nanotechnology-oriented techniques.
Collapse
Affiliation(s)
| | - Prabhahari Pownraj
- Nanosensor Laboratory, PSG Institute of Advanced Studies, Coimbatore641 004, India.
| | | | - Biji Pullithadathil
- Nanosensor Laboratory, PSG Institute of Advanced Studies, Coimbatore641 004, India.
| |
Collapse
|
27
|
|
28
|
Rohwedder JJR, Pasquini C, Fortes PR, Raimundo IM, Wilk A, Mizaikoff B. iHWG-μNIR: a miniaturised near-infrared gas sensor based on substrate-integrated hollow waveguides coupled to a micro-NIR-spectrophotometer. Analyst 2014; 139:3572-6. [DOI: 10.1039/c4an00556b] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|