1
|
Early infant diagnosis of HIV-1 infection in Luanda, Angola, using a new DNA PCR assay and dried blood spots. PLoS One 2017; 12:e0181352. [PMID: 28715460 PMCID: PMC5513534 DOI: 10.1371/journal.pone.0181352] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2017] [Accepted: 06/29/2017] [Indexed: 11/30/2022] Open
Abstract
Background Early diagnosis and treatment reduces HIV-1-related mortality, morbidity and size of viral reservoirs in infants infected perinatally. Commercial molecular tests enable the early diagnosis of infection in infants but the high cost and low sensitivity with dried blood spots (DBS) limit their use in sub-Saharan Africa. Objectives To develop and validate a sensitive and cheap qualitative proviral DNA PCR-based assay for early infant diagnosis (EID) in HIV-1-exposed infants using DBS samples. Study design Chelex-based method was used to extract DNA from DBS samples followed by a nested PCR assay using primers for the HIV-1 integrase gene. Limit of detection (LoD) was determined by Probit regression using limiting dilutions of newly produced recombinant plasmids with the integrase gene of all HIV-1 subtypes and ACH-2 cells. Clinical sensitivity and specificity were evaluated on 100 HIV-1 infected adults; 5 infected infants; 50 healthy volunteers; 139 HIV-1-exposed infants of the Angolan Pediatric HIV Cohort (APEHC) with serology at 18 months of life. Results All subtypes and CRF02_AG were amplified with a LoD of 14 copies. HIV-1 infection in infants was detected at month 1 of life. Sensitivity rate in adults varied with viral load, while diagnostic specificity was 100%. The percentage of HIV-1 MTCT cases between January 2012 and October 2014 was 2.2%. The cost per test was 8-10 USD which is 2- to 4-fold lower in comparison to commercial assays. Conclusions The new PCR assay enables early and accurate EID. The simplicity and low-cost of the assay make it suitable for generalized implementation in Angola and other resource-constrained countries.
Collapse
|
3
|
Performance of NucliSens HIV-1 EasyQ Version 2.0 compared with six commercially available quantitative nucleic acid assays for detection of HIV-1 in China. Mol Diagn Ther 2011; 14:305-16. [PMID: 21053996 DOI: 10.1007/bf03256386] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
Abstract
BACKGROUND AND OBJECTIVES Six HIV-1 viral load assays have been widely used in China. These include the Cobas Amplicor HIV-1 Monitor Version 1.5 ('Amplicor'), Cobas AmpliPrep/Cobas TaqMan HIV-1 test Version 1.0 ('CAP/CTM'), Versant HIV-1 RNA Version 3.0 (branched DNA [bDNA]-based assay; 'Versant bDNA'), Abbott RealTime HIV-1 assay ('Abbott RealTime'), NucliSens HIV-1 QT (nucleic acid sequence-based amplification assay; 'NucliSens NASBA'), and NucliSens EasyQ HIV-1 Version 1.1 ('EasyQ V1.1'). Recently, an updated version of EasyQ V1.1, NucliSens EasyQ HIV-1 Version 2.0 ('EasyQ V2.0') was introduced into China. It is important to evaluate the impact of HIV-1 genotypes on the updated assay compared with the other commercial available assays in China. METHODS A total of 175 plasma samples with different HIV-1 clades prevalent in China were collected from treatment-naïve patients. The viral loads of those samples were determined with the seven HIV-1 viral load assays, and the quantitative differences between them were evaluated. RESULTS Overall, EasyQ V2.0 exhibited a significant correlation (R = 0.769-0.850, p ≤ 0.001) and high agreement (94.77-97.13%, using the Bland-Altman model) with the other six assays. Although no significant differences between EasyQ V2.0 and the other six assays were observed when quantifying clade B' samples, there were statistically significant differences between EasyQ V2.0 and the Amplicor, Versant bDNA, and Abbott RealTime assays when quantifying clade BC samples, and between EasyQ V2.0 and the Versant bDNA and Abbott RealTime assays when quantifying clade AE samples. For clade BC samples, the quantitative differences between EasyQ V2.0 and the Amplicor, Versant bDNA, and Abbott RealTime assays exceeded 0.5 log(10) IU/mL in approximately 50% of samples and exceeded 1 log(10) IU/mL in approximately 15% of samples. For clade AE samples, the quantitative differences between EasyQ V2.0 and the CAP/CTM, Versant bDNA, and Abbott RealTime assays exceeded 0.5 log(10) IU/mL in approximately 50% of samples, and the differences between EasyQ V2.0 and CAP/CTM exceeded 1 log(10) IU/mL in approximately 15% of samples. CONCLUSION Genotypes may affect the quantification of HIV-1 RNA, especially in clade BC samples with respect to EasyQ V2.0 and the Amplicor, Versant bDNA, or Abbott RealTime assays, and in clade AE samples with respect to EasyQ V2.0 and the Versant bDNA or Abbott RealTime assays. It is therefore strongly suggested that, where possible, the HIV-1 viral load in infected patients be quantified at follow-up by the same version of the same assay that was used initially.
Collapse
|
4
|
Tehe A, Maurice C, Hanson DL, Borget MY, Abiola N, Maran M, Yavo D, Tomasik Z, Böni J, Schüpbach J, Nkengasong JN. Quantification of HIV-1 p24 by a highly improved ELISA: An alternative to HIV-1 RNA based treatment monitoring in patients from Abidjan, Côte d’Ivoire. J Clin Virol 2006; 37:199-205. [PMID: 16973409 DOI: 10.1016/j.jcv.2006.08.005] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2006] [Revised: 07/18/2006] [Accepted: 08/02/2006] [Indexed: 11/23/2022]
Abstract
BACKGROUND Quantification of HIV-1 RNA remains difficult to implement in Africa. Simple and inexpensive tests for antiretroviral treatment (ART) monitoring are needed. OBJECTIVE To evaluate an HIV-1 p24 ELISA, which combines efficient virus disruption, heat-denaturation and signal amplification, in a West African setting. STUDY DESIGN Eighty-six HIV-1 infected patients from Abidjan, Côte d'Ivoire, were tested for p24, HIV-1 RNA, and CD4+ count at baseline, and twice within 8 months after ART initiation. RESULTS All patients responded to ART with a minimal HIV-1 RNA drop of 0.5 log(10) at first follow-up. Forty-one (47.7%) then rebounded >0.5 log(10) or persisted above 1000 copies/mL by week 24. The predicted baseline concentration of p24 corresponding to 100,000 copies/mL of HIV-1 RNA, above which ART is recommended, was 4546 fg/mL (95% confidence interval 3148-6566). A prediction model of virologic failure, occurring after an initial response to ART, correctly classified 84% of patients using baseline p24, p24 change on therapy, and achievement of undetectable p24 as explanatory variables. The model and further bootstrap evaluation suggested a good ability to discriminate between sustained or failing virologic response to ART. CONCLUSION HIV-1 p24 and RNA based-ART monitoring in a low-resource country dominated by HIV-1 CRF02 AG appeared comparable.
Collapse
Affiliation(s)
- Andre Tehe
- Projet RETRO-CI, Abidjan, Côte d'Ivoire.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
5
|
Swanson P, de Mendoza C, Joshi Y, Golden A, Hodinka RL, Soriano V, Devare SG, Hackett J. Impact of human immunodeficiency virus type 1 (HIV-1) genetic diversity on performance of four commercial viral load assays: LCx HIV RNA Quantitative, AMPLICOR HIV-1 MONITOR v1.5, VERSANT HIV-1 RNA 3.0, and NucliSens HIV-1 QT. J Clin Microbiol 2005; 43:3860-8. [PMID: 16081923 PMCID: PMC1233972 DOI: 10.1128/jcm.43.8.3860-3868.2005] [Citation(s) in RCA: 86] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2004] [Revised: 04/22/2005] [Accepted: 05/06/2005] [Indexed: 11/20/2022] Open
Abstract
Human immunodeficiency virus type 1 (HIV-1) evolution and changing strain distribution present a challenge to nucleic acid-based assays. Reliable patient monitoring of viral loads requires the detection and accurate quantification of genetically diverse HIV-1. A panel of 97 HIV-1-seropositive plasma samples collected from Cameroon, Brazil, and South Africa was used to compare the performance of four commercially available HIV RNA quantitative tests: Abbott LCx HIV RNA Quantitative assay (LCx), Bayer Versant HIV-1 RNA 3.0 (bDNA), Roche AMPLICOR HIV-1 MONITOR v1.5 (Monitor v1.5), and bioMérieux NucliSens HIV-1 QT (NucliSens). The panel included group M, group O, and recombinant viruses based on sequence analysis of gag p24, pol integrase, and env gp41. The LCx HIV assay quantified viral RNA in 97 (100%) of the samples. In comparison, bDNA, Monitor v1.5, and NucliSens quantified viral RNA in 96.9%, 94.8%, and 88.6% of the samples, respectively. The two group O specimens were quantified only by the LCx HIV assay. Analysis of nucleotide mismatches at the primer/probe binding sites for Monitor v1.5, NucliSens, and LCx assays revealed that performance characteristics reflected differences in the level of genetic conservation within the target regions.
Collapse
Affiliation(s)
- Priscilla Swanson
- Abbott Laboratories, AIDS Research and Retrovirus Discovery, Abbott Park, Illinois 60064, Instituto de Salud Carlos III, Service of Infectious Diseases, Madrid, Spain, Clinical Virology Laboratory, Children's Hospital of Philadelphia, and Departments of Pediatrics and Pathology, University of Pennsylvania School of Medicine, Philadelphia, Pennsylvania 19104
| | - Carmen de Mendoza
- Abbott Laboratories, AIDS Research and Retrovirus Discovery, Abbott Park, Illinois 60064, Instituto de Salud Carlos III, Service of Infectious Diseases, Madrid, Spain, Clinical Virology Laboratory, Children's Hospital of Philadelphia, and Departments of Pediatrics and Pathology, University of Pennsylvania School of Medicine, Philadelphia, Pennsylvania 19104
| | - Yagnya Joshi
- Abbott Laboratories, AIDS Research and Retrovirus Discovery, Abbott Park, Illinois 60064, Instituto de Salud Carlos III, Service of Infectious Diseases, Madrid, Spain, Clinical Virology Laboratory, Children's Hospital of Philadelphia, and Departments of Pediatrics and Pathology, University of Pennsylvania School of Medicine, Philadelphia, Pennsylvania 19104
| | - Alan Golden
- Abbott Laboratories, AIDS Research and Retrovirus Discovery, Abbott Park, Illinois 60064, Instituto de Salud Carlos III, Service of Infectious Diseases, Madrid, Spain, Clinical Virology Laboratory, Children's Hospital of Philadelphia, and Departments of Pediatrics and Pathology, University of Pennsylvania School of Medicine, Philadelphia, Pennsylvania 19104
| | - Richard L. Hodinka
- Abbott Laboratories, AIDS Research and Retrovirus Discovery, Abbott Park, Illinois 60064, Instituto de Salud Carlos III, Service of Infectious Diseases, Madrid, Spain, Clinical Virology Laboratory, Children's Hospital of Philadelphia, and Departments of Pediatrics and Pathology, University of Pennsylvania School of Medicine, Philadelphia, Pennsylvania 19104
| | - Vincent Soriano
- Abbott Laboratories, AIDS Research and Retrovirus Discovery, Abbott Park, Illinois 60064, Instituto de Salud Carlos III, Service of Infectious Diseases, Madrid, Spain, Clinical Virology Laboratory, Children's Hospital of Philadelphia, and Departments of Pediatrics and Pathology, University of Pennsylvania School of Medicine, Philadelphia, Pennsylvania 19104
| | - Sushil G. Devare
- Abbott Laboratories, AIDS Research and Retrovirus Discovery, Abbott Park, Illinois 60064, Instituto de Salud Carlos III, Service of Infectious Diseases, Madrid, Spain, Clinical Virology Laboratory, Children's Hospital of Philadelphia, and Departments of Pediatrics and Pathology, University of Pennsylvania School of Medicine, Philadelphia, Pennsylvania 19104
| | - John Hackett
- Abbott Laboratories, AIDS Research and Retrovirus Discovery, Abbott Park, Illinois 60064, Instituto de Salud Carlos III, Service of Infectious Diseases, Madrid, Spain, Clinical Virology Laboratory, Children's Hospital of Philadelphia, and Departments of Pediatrics and Pathology, University of Pennsylvania School of Medicine, Philadelphia, Pennsylvania 19104
| |
Collapse
|