1
|
Xie M, Liao M, Chen S, Zhu D, Zeng Q, Wang P, Su C, Lian R, Chen J, Zhang J. Cell spray printing combined with Lycium barbarum glycopeptide promotes repair of corneal epithelial injury. Exp Eye Res 2024; 244:109928. [PMID: 38750781 DOI: 10.1016/j.exer.2024.109928] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2024] [Revised: 04/29/2024] [Accepted: 05/12/2024] [Indexed: 05/19/2024]
Abstract
The corneal epithelium, located as the outermost layer of the cornea, is inherently susceptible to injuries that may lead to corneal opacities and compromise visual acuity. Rapid restoration of corneal epithelial injury is crucial for maintaining the transparency and integrity of the cornea. Cell spray treatment emerges as an innovative and effective approach in the field of regenerative medicine. In our study, a cell spray printing platform was established, and the optimal printing parameters were determined to be a printing air pressure of 5 PSI (34.47 kPa) and a liquid flow rate of 30 ml/h. Under these conditions, the viability and phenotype of spray-printed corneal epithelial cells were preserved. Moreover, Lycium barbarum glycopeptide (LBGP), a glycoprotein purified from wolfberry, enhanced proliferation while simultaneously inhibiting apoptosis of the spray-printed corneal epithelial cells. We found that the combination of cell spray printing and LBGP facilitated the rapid construction of multilayered cell sheets on flat and curved collagen membranes in vitro. Furthermore, the combined cell spray printing and LBGP accelerated the recovery of the rat corneal epithelium in the mechanical injury model. Our findings offer a therapeutic avenue for addressing corneal epithelial injuries and regeneration.
Collapse
Affiliation(s)
- Mengyuan Xie
- Department of Optoelectronic Engineering, College of Physics and Optoelectronic Engineering, Jinan University, Guangzhou, 510632, China
| | - Meizhong Liao
- Department of Optoelectronic Engineering, College of Physics and Optoelectronic Engineering, Jinan University, Guangzhou, 510632, China
| | - Sihui Chen
- Ophthalmology Department, The First Affiliated Hospital of Jinan University, Guangzhou, 510632, China
| | - Deliang Zhu
- Guangdong Cardiovascular Institute, Medical Research Institute, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou, 510080, China
| | - Qiaolang Zeng
- Department of Ophthalmology, Central South University Xiangya School of Medicine Affiliated Haikou Hospital, Haikou, 570000, China
| | - Peiyuan Wang
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, 510623, China
| | - Caiying Su
- Peking University Shenzhen Hospital, Shenzhen, 518036, China
| | - Ruiling Lian
- Aier Eye Institute, Changsha, Hunan, 410015, China
| | - Jiansu Chen
- Ophthalmology Department, The First Affiliated Hospital of Jinan University, Guangzhou, 510632, China; Aier Eye Institute, Changsha, Hunan, 410015, China; Key Laboratory for Regenerative Medicine, Ministry of Education, Jinan University, Guangzhou, 510632, China.
| | - Jun Zhang
- Department of Optoelectronic Engineering, College of Physics and Optoelectronic Engineering, Jinan University, Guangzhou, 510632, China; Guangdong Provincial Engineering Technology Research Center on Visible Light Communication, Jinan University, Guangzhou, 510632, China.
| |
Collapse
|
2
|
Cheremkhina M, Klein S, Babendreyer A, Ludwig A, Schmitz-Rode T, Jockenhoevel S, Cornelissen CG, Thiebes AL. Influence of Aerosolization on Endothelial Cells for Efficient Cell Deposition in Biohybrid and Regenerative Applications. MICROMACHINES 2023; 14:575. [PMID: 36984982 PMCID: PMC10053765 DOI: 10.3390/mi14030575] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/20/2022] [Revised: 02/11/2023] [Accepted: 02/25/2023] [Indexed: 06/18/2023]
Abstract
The endothelialization of gas exchange membranes can increase the hemocompatibility of extracorporeal membrane oxygenators and thus become a long-term lung replacement option. Cell seeding on large or uneven surfaces of oxygenator membranes is challenging, with cell aerosolization being a possible solution. In this study, we evaluated the endothelial cell aerosolization for biohybrid lung application. A Vivostat® system was used for the aerosolization of human umbilical vein endothelial cells with non-sprayed cells serving as a control. The general suitability was evaluated using various flow velocities, substrate distances and cell concentrations. Cells were analyzed for survival, apoptosis and necrosis levels. In addition, aerosolized and non-sprayed cells were cultured either static or under flow conditions in a dynamic microfluidic model. Evaluation included immunocytochemistry and gene expression via quantitative PCR. Cell survival for all tested parameters was higher than 90%. No increase in apoptosis and necrosis levels was seen 24 h after aerosolization. Spraying did not influence the ability of the endothelial cells to form a confluent cell layer and withstand shear stresses in a dynamic microfluidic model. Immunocytochemistry revealed typical expression of CD31 and von Willebrand factor with cobble-stone cell morphology. No change in shear stress-induced factors after aerosolization was reported by quantitative PCR analysis. With this study, we have shown the feasibility of endothelial cell aerosolization with no significant changes in cell behavior. Thus, this technique could be used for efficient the endothelialization of gas exchange membranes in biohybrid lung applications.
Collapse
Affiliation(s)
- Maria Cheremkhina
- Department of Biohybrid & Medical Textiles (BioTex), AME-Institute of Applied Medical Engineering, Helmholtz Institute Aachen, RWTH Aachen University, Forckenbeckstraße 55, 52074 Aachen, Germany
- Aachen-Maastricht Institute for Biobased Materials, Faculty of Science and Engineering, Maastricht University, Brightlands Chemelot Campus, Urmonderbaan 22, 6167 RD Geleen, The Netherlands
| | - Sarah Klein
- Department of Biohybrid & Medical Textiles (BioTex), AME-Institute of Applied Medical Engineering, Helmholtz Institute Aachen, RWTH Aachen University, Forckenbeckstraße 55, 52074 Aachen, Germany
- Aachen-Maastricht Institute for Biobased Materials, Faculty of Science and Engineering, Maastricht University, Brightlands Chemelot Campus, Urmonderbaan 22, 6167 RD Geleen, The Netherlands
| | - Aaron Babendreyer
- Institute of Molecular Pharmacology, University Hospital RWTH Aachen, Wendlingweg 2, 52074 Aachen, Germany
| | - Andreas Ludwig
- Institute of Molecular Pharmacology, University Hospital RWTH Aachen, Wendlingweg 2, 52074 Aachen, Germany
| | - Thomas Schmitz-Rode
- Department of Biohybrid & Medical Textiles (BioTex), AME-Institute of Applied Medical Engineering, Helmholtz Institute Aachen, RWTH Aachen University, Forckenbeckstraße 55, 52074 Aachen, Germany
| | - Stefan Jockenhoevel
- Department of Biohybrid & Medical Textiles (BioTex), AME-Institute of Applied Medical Engineering, Helmholtz Institute Aachen, RWTH Aachen University, Forckenbeckstraße 55, 52074 Aachen, Germany
- Aachen-Maastricht Institute for Biobased Materials, Faculty of Science and Engineering, Maastricht University, Brightlands Chemelot Campus, Urmonderbaan 22, 6167 RD Geleen, The Netherlands
| | - Christian G. Cornelissen
- Department of Biohybrid & Medical Textiles (BioTex), AME-Institute of Applied Medical Engineering, Helmholtz Institute Aachen, RWTH Aachen University, Forckenbeckstraße 55, 52074 Aachen, Germany
- Department of Pneumology and Internal Intensive Care Medicine, Medical Clinic V, University Hospital RWTH Aachen, Pauwelsstraße 30, 52074 Aachen, Germany
| | - Anja Lena Thiebes
- Department of Biohybrid & Medical Textiles (BioTex), AME-Institute of Applied Medical Engineering, Helmholtz Institute Aachen, RWTH Aachen University, Forckenbeckstraße 55, 52074 Aachen, Germany
- Aachen-Maastricht Institute for Biobased Materials, Faculty of Science and Engineering, Maastricht University, Brightlands Chemelot Campus, Urmonderbaan 22, 6167 RD Geleen, The Netherlands
| |
Collapse
|
3
|
Thiebes AL, Klein S, Zingsheim J, Möller GH, Gürzing S, Reddemann MA, Behbahani M, Jockenhoevel S, Cornelissen CG. Effervescent Atomizer as Novel Cell Spray Technology to Decrease the Gas-to-Liquid Ratio. Pharmaceutics 2022; 14:pharmaceutics14112421. [PMID: 36365239 PMCID: PMC9697195 DOI: 10.3390/pharmaceutics14112421] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2022] [Revised: 10/27/2022] [Accepted: 11/03/2022] [Indexed: 11/11/2022] Open
Abstract
Cell spraying has become a feasible application method for cell therapy and tissue engineering approaches. Different devices have been used with varying success. Often, twin-fluid atomizers are used, which require a high gas velocity for optimal aerosolization characteristics. To decrease the amount and velocity of required air, a custom-made atomizer was designed based on the effervescent principle. Different designs were evaluated regarding spray characteristics and their influence on human adipose-derived mesenchymal stromal cells. The arithmetic mean diameters of the droplets were 15.4−33.5 µm with decreasing diameters for increasing gas-to-liquid ratios. The survival rate was >90% of the control for the lowest gas-to-liquid ratio. For higher ratios, cell survival decreased to approximately 50%. Further experiments were performed with the design, which had shown the highest survival rates. After seven days, no significant differences in metabolic activity were observed. The apoptosis rates were not influenced by aerosolization, while high gas-to-liquid ratios caused increased necrosis levels. Tri-lineage differentiation potential into adipocytes, chondrocytes, and osteoblasts was not negatively influenced by aerosolization. Thus, the effervescent aerosolization principle was proven suitable for cell applications requiring reduced amounts of supplied air. This is the first time an effervescent atomizer was used for cell processing.
Collapse
Affiliation(s)
- Anja Lena Thiebes
- Department of Biohybrid & Medical Textiles (BioTex), AME—Institute of Applied Medical Engineering, Helmholtz Institute Aachen, RWTH Aachen University, Forckenbeckstraße 55, 52074 Aachen, Germany
- Aachen-Maastricht Institute for Biobased Materials, Faculty of Science and Engineering, Maastricht University, Brightlands Chemelot Campus, Urmonderbaan 22, 6167 RD Geleen, The Netherlands
- Correspondence: (A.L.T.); (S.J.); Tel.: +49-241-80-47472 (A.L.T.); +49-241-80-47478 (S.J.)
| | - Sarah Klein
- Department of Biohybrid & Medical Textiles (BioTex), AME—Institute of Applied Medical Engineering, Helmholtz Institute Aachen, RWTH Aachen University, Forckenbeckstraße 55, 52074 Aachen, Germany
- Aachen-Maastricht Institute for Biobased Materials, Faculty of Science and Engineering, Maastricht University, Brightlands Chemelot Campus, Urmonderbaan 22, 6167 RD Geleen, The Netherlands
| | - Jonas Zingsheim
- Department of Biohybrid & Medical Textiles (BioTex), AME—Institute of Applied Medical Engineering, Helmholtz Institute Aachen, RWTH Aachen University, Forckenbeckstraße 55, 52074 Aachen, Germany
- Laboratory Biomaterial, University of Applied Sciences Aachen, Heinrich-Mußmann-Straße 1, 52428 Jülich, Germany
| | - Georg H. Möller
- Institute of Heat and Mass Transfer (WSA), RWTH Aachen University, Augustinerbach 6, 52056 Aachen, Germany
| | - Stefanie Gürzing
- Institute of Heat and Mass Transfer (WSA), RWTH Aachen University, Augustinerbach 6, 52056 Aachen, Germany
| | - Manuel A. Reddemann
- Institute of Heat and Mass Transfer (WSA), RWTH Aachen University, Augustinerbach 6, 52056 Aachen, Germany
| | - Mehdi Behbahani
- Laboratory Biomaterial, University of Applied Sciences Aachen, Heinrich-Mußmann-Straße 1, 52428 Jülich, Germany
| | - Stefan Jockenhoevel
- Department of Biohybrid & Medical Textiles (BioTex), AME—Institute of Applied Medical Engineering, Helmholtz Institute Aachen, RWTH Aachen University, Forckenbeckstraße 55, 52074 Aachen, Germany
- Aachen-Maastricht Institute for Biobased Materials, Faculty of Science and Engineering, Maastricht University, Brightlands Chemelot Campus, Urmonderbaan 22, 6167 RD Geleen, The Netherlands
- Correspondence: (A.L.T.); (S.J.); Tel.: +49-241-80-47472 (A.L.T.); +49-241-80-47478 (S.J.)
| | - Christian G. Cornelissen
- Department of Biohybrid & Medical Textiles (BioTex), AME—Institute of Applied Medical Engineering, Helmholtz Institute Aachen, RWTH Aachen University, Forckenbeckstraße 55, 52074 Aachen, Germany
- Department of Pneumology and Internal Intensive Care Medicine, Medical Clinic V, University Hospital RWTH Aachen, Pauwelsstraße 30, 52074 Aachen, Germany
| |
Collapse
|
4
|
Motamedi S, Esfandpour A, Babajani A, Jamshidi E, Bahrami S, Niknejad H. The Current Challenges on Spray-Based Cell Delivery to the Skin Wounds. Tissue Eng Part C Methods 2021; 27:543-558. [PMID: 34541897 DOI: 10.1089/ten.tec.2021.0158] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022] Open
Abstract
Cell delivery through spray instruments is a promising and effective method in tissue engineering and regenerative medicine. It is used for treating different acute and chronic wounds, including burns with different etiologies, chronic diabetic or venous wounds, postcancer surgery, and hypopigmentation disorders. Cell spray can decrease the needed donor site area compared with conventional autologous skin grafting. Keratinocytes, fibroblasts, melanocytes, and mesenchymal stem cells are promising cell sources for cell spray procedures. Different spray instruments are designed and utilized to deliver the cells to the intended skin area. In an efficient spray instrument, cell viability and wound coverage are two determining parameters influenced by various physical and biological factors such as air pressure, spraying distance, viscosity of suspension, stiffness of the wound surface, and velocity of impact. Besides, to improve cell delivery by spray instruments, some matrices and growth factors can be added to cell suspensions. This review focuses on the different types of cells and spray instruments used in cell delivery procedures. It also discusses physical and biological parameters associated with cell viability and wound coverage in spray instruments. Moreover, the recent advances in codelivery of cells with biological glues and growth factors, as well as clinical translation of cell spraying, have been reviewed. Impact statement Skin wounds are a group of prevalent injuries that can lead to life-threatening complexities. As a focus of interest, stem cell therapy and spray-based cell delivery have effectively decreased associated morbidity and mortality. This review summarizes a broad scope of recent evidence related to spray-based cell therapy, instruments, and approaches adopted to make the process more efficient in treating skin wounds. An overview including utilized cell types, clinical cases, and current challenges is also provided.
Collapse
Affiliation(s)
- Shiva Motamedi
- Department of Pharmacology, School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Arefeh Esfandpour
- Department of Pharmacology, School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Amirhesam Babajani
- Department of Pharmacology, School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Elham Jamshidi
- Department of Pharmacology, School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Soheyl Bahrami
- Ludwig Boltzmann Institute for Experimental and Clinical Traumatology in AUVA Research Center, Vienna, Austria
| | - Hassan Niknejad
- Department of Pharmacology, School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| |
Collapse
|
5
|
Liu J, Yao X, Wang Z, Ye J, Luan C, He Y, Lin H, Fu J. A flexible porous chiral auxetic tracheal stent with ciliated epithelium. Acta Biomater 2021; 124:153-165. [PMID: 33529770 DOI: 10.1016/j.actbio.2021.01.044] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2020] [Revised: 01/24/2021] [Accepted: 01/26/2021] [Indexed: 12/13/2022]
Abstract
Tracheal stent placement is a principal treatment for tracheobronchial stenosis, but complications such as mucus plugging, secondary stenosis, migration, and strong foreign body sensation remain unavoidable challenges. In this study, we designed a flexible porous chiral tracheal stent intended to reduce or overcome these complications. The stent was innovatively designed with a flexible tetrachiral and anti-tetrachiral hybrid structure as the frame and hollows filled with porous silicone sponge. Detailed finite element analysis (FEA) showed that the designed frame can maintain a Poisson's ratio that is negative or close to zero at up to 50% tensile strain. This contributes to improved airway ventilation and better resistance to migration during physiological activities such as respiration and neck movement. The preparation process combined indirect 3D printing with gas foaming and particulate leaching methods to efficiently fabricate the stent. The stent was then subjected to uniaxial tension and local radial compression tests, which indicated that it not only has the same desirable auxetic performance but also has flexibility similar to the native trachea. The porous sponge facilitated the adhesion of cells, allowed nutrient diffusion, and would prevent the ingrowth of granulation tissue. Furthermore, a ciliated tracheal epithelium similar to that of the native trachea was differentiated from normal human bronchial primary epithelial cells on the internal wall of the stent under air-liquid interface conditions. These results suggest that the designed stent has the potential for application in the treatment of tracheobronchial stenosis.
Collapse
Affiliation(s)
- Jiapeng Liu
- State Key Laboratory of Fluid Power & Mechatronic Systems, College of Mechanical Engineering, Zhejiang University, Hangzhou 310027, People's Republic of China; Key Laboratory of 3D Printing Process and Equipment of Zhejiang Province, College of Mechanical Engineering, Zhejiang University, Hangzhou 310027, People's Republic of China
| | - Xinhua Yao
- State Key Laboratory of Fluid Power & Mechatronic Systems, College of Mechanical Engineering, Zhejiang University, Hangzhou 310027, People's Republic of China; Key Laboratory of 3D Printing Process and Equipment of Zhejiang Province, College of Mechanical Engineering, Zhejiang University, Hangzhou 310027, People's Republic of China.
| | - Zhenwei Wang
- State Key Laboratory of Fluid Power & Mechatronic Systems, College of Mechanical Engineering, Zhejiang University, Hangzhou 310027, People's Republic of China; Key Laboratory of 3D Printing Process and Equipment of Zhejiang Province, College of Mechanical Engineering, Zhejiang University, Hangzhou 310027, People's Republic of China
| | - Jian Ye
- Department of Pneumology, Affiliated Hangzhou First People's Hospital, Zhejiang University School of Medicine, Hangzhou 310006, People's Republic of China
| | - Congcong Luan
- State Key Laboratory of Fluid Power & Mechatronic Systems, College of Mechanical Engineering, Zhejiang University, Hangzhou 310027, People's Republic of China; Key Laboratory of 3D Printing Process and Equipment of Zhejiang Province, College of Mechanical Engineering, Zhejiang University, Hangzhou 310027, People's Republic of China
| | - Yong He
- State Key Laboratory of Fluid Power & Mechatronic Systems, College of Mechanical Engineering, Zhejiang University, Hangzhou 310027, People's Republic of China; Key Laboratory of 3D Printing Process and Equipment of Zhejiang Province, College of Mechanical Engineering, Zhejiang University, Hangzhou 310027, People's Republic of China
| | - Hui Lin
- Department of General Surgery, Sir Run Run Shaw Hospital, School of Medicine, Zhejiang University, Hangzhou, Zhejiang 310058, People's Republic of China
| | - Jianzhong Fu
- State Key Laboratory of Fluid Power & Mechatronic Systems, College of Mechanical Engineering, Zhejiang University, Hangzhou 310027, People's Republic of China; Key Laboratory of 3D Printing Process and Equipment of Zhejiang Province, College of Mechanical Engineering, Zhejiang University, Hangzhou 310027, People's Republic of China
| |
Collapse
|
6
|
Thiebes AL, Uhl FE, Hauser M, Cornelissen CG, Jockenhoevel S, Weiss DJ. Endoscopic atomization of mesenchymal stromal cells: in vitro study for local cell therapy of the lungs. Cytotherapy 2021; 23:293-300. [PMID: 33526382 DOI: 10.1016/j.jcyt.2020.12.010] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2020] [Revised: 12/17/2020] [Accepted: 12/21/2020] [Indexed: 01/01/2023]
Abstract
BACKGROUND AIMS Cell-based therapies of pulmonary diseases with mesenchymal stromal cells (MSCs) are increasingly under experimental investigation. In most of these, MSCs are administered intravenously or by direct intratracheal instillation. A parallel approach is to administer the cells into the lung by endoscopic atomization (spraying). In a previous study, the authors developed a flexible endoscopic atomization device that allows administration of respiratory epithelial cells in the lungs with high survival. METHODS In this study, the authors evaluated the feasibility of spraying MSCs with two different endoscopic atomization devices (air and pressure atomization). Following atomization, cell viability was evaluated with live/dead staining. Subsequent effects on cytotoxicity, trilineage differentiation and expression of MSC-specific markers as well as on MSC metabolic activity and morphology were analyzed for up to 7 days. RESULTS MSC viability immediately after spraying and subsequent metabolic activity for 7 days was not influenced by either of the devices. Slightly higher cytotoxicity rates could be observed for pressure-atomized compared with control and air-atomized MSCs over 7 days. Flow cytometry revealed no changes in characteristic MSC cell surface marker expression, and morphology remained unchanged. Standard differentiation into osteocytes, chondrocytes and adipocytes was inducible after atomization. CONCLUSIONS In the literature, a minimal survival of 50% was previously defined as the cutoff value for successful cell atomization. This is easily met with both of the authors' devices, with more than 90% survival. Thus, there is a potential role for atomization in intrapulmonary MSC-based cell therapies, as it is a feasible and easily utilizable approach based on clinically available equipment.
Collapse
Affiliation(s)
- Anja Lena Thiebes
- Department of Biohybrid & Medical Textiles, Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Aachen, Germany; Vermont Lung Center, University of Vermont, Burlington, Vermont, USA; Aachen-Maastricht Institute for Biobased Materials, Faculty of Science and Engineering, Maastricht University, Geleen, the Netherlands.
| | - Franziska E Uhl
- Vermont Lung Center, University of Vermont, Burlington, Vermont, USA; Department of Experimental Medical Sciences, Lund University, Lund, Sweden; Wallenberg Centre for Molecular Medicine, Lund University, Lund, Sweden
| | - Marie Hauser
- Department of Biohybrid & Medical Textiles, Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Aachen, Germany
| | - Christian G Cornelissen
- Department of Biohybrid & Medical Textiles, Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Aachen, Germany; Clinic for Pneumology and Internistic Intensive Medicine (Medical Clinic V), University Hospital Aachen, Aachen, Germany
| | - Stefan Jockenhoevel
- Department of Biohybrid & Medical Textiles, Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Aachen, Germany; Aachen-Maastricht Institute for Biobased Materials, Faculty of Science and Engineering, Maastricht University, Geleen, the Netherlands
| | - Daniel J Weiss
- Vermont Lung Center, University of Vermont, Burlington, Vermont, USA
| |
Collapse
|
7
|
Chang M, Liu J, Guo B, Fang X, Wang Y, Wang S, Liu X, Reid LM, Wang Y. Auto Micro Atomization Delivery of Human Epidermal Organoids Improves Therapeutic Effects for Skin Wound Healing. Front Bioeng Biotechnol 2020; 8:110. [PMID: 32154237 PMCID: PMC7046802 DOI: 10.3389/fbioe.2020.00110] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2019] [Accepted: 02/04/2020] [Indexed: 12/11/2022] Open
Abstract
Severe skin wounds are often associated with large areas of damaged tissue, resulting in substantial loss of fluids containing electrolytes and proteins. The net result is a vulnerability clinically to skin infections. Therapies aiming to close these large openings are effective in reducing the complications of severe skin wounds. Recently, cell transplantation therapy showed the potential for rapid re-epithelialization of severe skin wounds. Here, we show the improved effects of cell transplantation therapy using a robust protocol of efficient expansion and delivery of epidermal cells for treatment of severe skin wounds. Human skin tissues were used to generate human epidermal organoids maintained under newly established culture conditions. The human epidermal organoids showed an improved capacity of passaging for at least 10 rounds, enabling organoids to expand to cell numbers required for clinical applications. A newly designed auto micro-atomization device (AMAD) was developed for delivery of human epidermal organoids onto the sites of severe skin wounds enhancing uniform and concentrated delivery of organoids, facilitating their engraftment and differentiation for skin reconstitution. With the optimal design and using pneumatic AMAD, both survival and functions of organoids were effectively protected during the spraying process. Cells in the sprayed human epidermal organoids participated in the regeneration of the epidermis at wound sites in a mouse model and accelerated wound healing significantly. The novel AMAD and out new protocol with enhanced effects with respect to both organoid expansion and efficient transplantation will be used for clincal treatments of complex, uneven, or large-area severe skin wounds.
Collapse
Affiliation(s)
- Mingyang Chang
- Stem Cell and Tissue Engineering Lab, Institute of Health Service and Transfusion Medicine, Beijing, China.,Translational Research Center, Beijing Tsinghua Changgung Hospital, Tsinghua University, Beijing, China
| | - Juan Liu
- Translational Research Center, Beijing Tsinghua Changgung Hospital, Tsinghua University, Beijing, China
| | - Baolin Guo
- Stem Cell and Tissue Engineering Lab, Institute of Health Service and Transfusion Medicine, Beijing, China
| | - Xin Fang
- The State Key Laboratory of Nonlinear Mechanics, Institute of Mechanics, Chinese Academy of Sciences, Beijing, China
| | - Yi Wang
- Stem Cell and Tissue Engineering Lab, Institute of Health Service and Transfusion Medicine, Beijing, China
| | - Shuyong Wang
- Stem Cell and Tissue Engineering Lab, Institute of Health Service and Transfusion Medicine, Beijing, China.,Army Tuberculosis Prevention and Control Key Laboratory, Institute of Tuberculosis Research, The 8th Medical Center of Chinese PLA General Hospital, Beijing, China
| | - Xiaofang Liu
- Department of Obstetrics and Gynecology, Air Force Medical Center, Chinese People's Liberation Army (PLA), Beijing, China
| | - Lola M Reid
- Department of Cell Biology and Physiology and Program in Molecular Biology and Biotechnology, University of North Carolina School of Medicine, Chapel Hill, NC, United States
| | - Yunfang Wang
- Stem Cell and Tissue Engineering Lab, Institute of Health Service and Transfusion Medicine, Beijing, China.,Translational Research Center, Beijing Tsinghua Changgung Hospital, Tsinghua University, Beijing, China
| |
Collapse
|
8
|
Dijkstra K, Huitsing RP, Custers RJ, Kouwenhoven JWM, Bleys RL, Vonk LA, Saris DB. Preclinical Feasibility of the Bio-Airbrush for Arthroscopic Cell-Based Cartilage Repair. Tissue Eng Part C Methods 2019; 25:379-388. [DOI: 10.1089/ten.tec.2019.0050] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Affiliation(s)
- Koen Dijkstra
- Department of Orthopedics, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Roeland P.J. Huitsing
- Department of Orthopedics, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Roel J.H. Custers
- Department of Orthopedics, University Medical Center Utrecht, Utrecht, The Netherlands
| | | | - Ronald L.A.W. Bleys
- Department of Anatomy, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Lucienne A. Vonk
- Department of Orthopedics, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Daniël B.F. Saris
- Department of Orthopedics, University Medical Center Utrecht, Utrecht, The Netherlands
- MIRA Institute for Biotechnology and Technical Medicine, University of Twente, Enschede, The Netherlands
- Department of Orthopedics, Mayo Clinic, Rochester, Minnesota
| |
Collapse
|
9
|
Schwartz DM, Pehlivaner Kara MO, Goldstein AM, Ott HC, Ekenseair AK. Spray Delivery of Intestinal Organoids to Reconstitute Epithelium on Decellularized Native Extracellular Matrix. Tissue Eng Part C Methods 2017; 23:565-573. [PMID: 28756760 PMCID: PMC5592844 DOI: 10.1089/ten.tec.2017.0269] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2017] [Accepted: 07/18/2017] [Indexed: 11/13/2022] Open
Abstract
The native extracellular matrix (ECM) serves as a unique platform for tissue engineering because it provides an organ-specific scaffold in terms of both matrix composition and tissue architecture. However, efficacious cell-seeding techniques for recellularizing the ECM constructs with appropriate cell types to restore biological function remain under development. In this study, the impact of spraying as a seeding technique for repopulation of decellularized small intestine was investigated. In a series of experiments, CaCo-2 cells were first used to investigate the effect of spray device type and pressure on cell viability and to optimize parameters for seeding intestinal epithelial cells. High cell viability and a homogeneous cell distribution were obtained when cell suspensions were sprayed through an airbrush at low pressure. Next, the effect of seeding method and spray pressure on the size and dispersal of intestinal organoids, a more complex and clinically relevant intestinal stem cell population, was evaluated. The feasibility of seeding intestinal epithelial cells onto decellularized scaffolds was next studied using sprayed CaCo-2 cells, which survived the spray-seeding process and formed a monolayer on the scaffold. Finally, airbrush seeding was used to spray intestinal organoids onto the scaffolds, with cell survival and tissue architecture evaluated after 1 week of culture. Organoids seeded through pipetting onto the decellularized scaffold survived, but demonstrated aggregation, with cells organized around multiple small lumens. In contrast, organoids airbrush spray seeded at 0.35 bar onto the decellularized scaffold not only engrafted but also demonstrated formation of an epithelial monolayer that resembled the absorptive surface found on intestinal villi. The results suggest that seeding cells through airbrush spraying holds great potential for use in tissue engineering, especially for large-scale tubular organ recellularization.
Collapse
Affiliation(s)
- Dana M Schwartz
- 1 Division of Pediatric Surgery, Department of Surgery, Massachusetts General Hospital , Boston, Massachusetts
| | | | - Allan M Goldstein
- 1 Division of Pediatric Surgery, Department of Surgery, Massachusetts General Hospital , Boston, Massachusetts
| | - Harald C Ott
- 3 Division of Thoracic Surgery, Department of Surgery, Massachusetts General Hospital , Boston, Massachusetts
| | - Adam K Ekenseair
- 2 Department of Chemical Engineering, Northeastern University , Boston, Massachusetts
| |
Collapse
|
10
|
O'Boyle N, Sutherland E, Berry CC, Davies RL. Temporal dynamics of ovine airway epithelial cell differentiation at an air-liquid interface. PLoS One 2017; 12:e0181583. [PMID: 28746416 PMCID: PMC5529025 DOI: 10.1371/journal.pone.0181583] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2017] [Accepted: 07/03/2017] [Indexed: 12/17/2022] Open
Abstract
The respiratory tract and lungs are subject to diverse pathologies with wide-ranging implications for both human and animal welfare. The development and detailed characterization of cell culture models for studying such forms of disease is of critical importance. In recent years the use of air-liquid interface (ALI)-cultured airway epithelial cells has increased markedly, as this method of culture results in the formation of a highly representative, organotypic in vitro model system. In this study we have expanded on previous knowledge of differentiated ovine tracheal epithelial cells by analysing the progression of differentiation over an extensive time course at an ALI. We observed a pseudo-stratified epithelium with ciliation and a concurrent increase in cell layer thickness from 9 days post-ALI with ciliation approaching a maximum level at day 24. A similar pattern was observed with respect to mucus production with intensely stained PAS-positive cells appearing at day 12. Ultrastructural analysis by SEM confirmed the presence of both ciliated cells and mucus globules on the epithelial surface within this time-frame. Trans-epithelial electrical resistance (TEER) peaked at 1049 Ω × cm2 as the cell layer became confluent, followed by a subsequent reduction as differentiation proceeded and stabilization at ~200 Ω × cm2. Importantly, little deterioration or de-differentiation was observed over the 45 day time-course indicating that the model is suitable for long-term experiments.
Collapse
Affiliation(s)
- Nicky O'Boyle
- Institute of Infection, Immunity and Inflammation, College of Medical, Veterinary and Life Sciences, University of Glasgow, Glasgow, United Kingdom
| | - Erin Sutherland
- Institute of Infection, Immunity and Inflammation, College of Medical, Veterinary and Life Sciences, University of Glasgow, Glasgow, United Kingdom
| | - Catherine C Berry
- Institute of Molecular Cell and Systems Biology, College of Medical, Veterinary and Life Sciences, University of Glasgow, Glasgow, United Kingdom
| | - Robert L Davies
- Institute of Infection, Immunity and Inflammation, College of Medical, Veterinary and Life Sciences, University of Glasgow, Glasgow, United Kingdom
| |
Collapse
|
11
|
Thiebes AL, Kelly N, Sweeney CA, McGrath DJ, Clauser J, Kurtenbach K, Gesche VN, Chen W, Kok RJ, Steinseifer U, Bruzzi M, O’Brien BJ, McHugh PE, Jockenhoevel S, Cornelissen CG. PulmoStent: In Vitro to In Vivo Evaluation of a Tissue Engineered Endobronchial Stent. Ann Biomed Eng 2016; 45:873-883. [DOI: 10.1007/s10439-016-1737-9] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2016] [Accepted: 09/15/2016] [Indexed: 11/25/2022]
|
12
|
Pehlivaner Kara MO, Ekenseair AK. In situspray deposition of cell-loaded, thermally and chemically gelling hydrogel coatings for tissue regeneration. J Biomed Mater Res A 2016; 104:2383-93. [DOI: 10.1002/jbm.a.35774] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2016] [Revised: 04/21/2016] [Accepted: 05/04/2016] [Indexed: 01/19/2023]
Affiliation(s)
- Meryem O. Pehlivaner Kara
- Department of Chemical Engineering; Northeastern University; 360 Huntington Avenue, 313 SN Boston Massachusetts 02115
| | - Adam K. Ekenseair
- Department of Chemical Engineering; Northeastern University; 360 Huntington Avenue, 313 SN Boston Massachusetts 02115
| |
Collapse
|
13
|
Thiebes AL, Reddemann MA, Palmer J, Kneer R, Jockenhoevel S, Cornelissen CG. Flexible Endoscopic Spray Application of Respiratory Epithelial Cells as Platform Technology to Apply Cells in Tubular Organs. Tissue Eng Part C Methods 2016; 22:322-31. [PMID: 26739252 PMCID: PMC4827297 DOI: 10.1089/ten.tec.2015.0381] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
Introduction: Inoperable airway stenoses are currently treated by placing stents. A major problem of covered stents is missing mucociliary clearance, which is caused by covering the native respiratory epithelium. By coating a stent with respiratory epithelium, this problem can be overcome. However, no methods are available for efficient endoscopic cell seeding. Methods: We designed a flexible endoscopic spraying device based on a bronchoscope and tested it with respiratory epithelial cells. With this device cells can also be applied in a thin layer of fibrin glue. We evaluated the survival rate directly after spray application with a live-dead staining and the long-term differentiation capacity with histology and electron microscopy. Furthermore, the random distribution of cells when applied in a tube was analyzed and the macroscopic and microscopic characteristics of the endoscopic spray were investigated using high-speed visualization. Results: Spray visualization revealed a polydisperse character of the spray with the majority of droplets larger than epithelial cells. Spray application does not influence the survival rate and differentiation of respiratory epithelial cells. After 4 weeks, cells built up a pseudostratified epithelial layer with cilia and goblet cells. When cells are applied in a thin layer of fibrin gel into a tube, a nearest neighbor index of 1.2 is obtained, which suggests a random distribution of the cells. Conclusions: This spraying device is a promising tool for application of various cell types onto stents or implants with high survival rates and homogeneous distribution as shown in this study for ovine respiratory epithelial cells. The system could also be used for cell therapy to locally apply cells to the diseased parts of hollow organs. For the first time, the fluid dynamics of a spray device for cells were examined to validate in vitro results.
Collapse
Affiliation(s)
- Anja Lena Thiebes
- 1 Department of Tissue Engineering and Textile Implants, Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University , Aachen, Germany
| | | | - Johannes Palmer
- 2 Institute of Heat and Mass Transfer, RWTH Aachen University , Aachen, Germany
| | - Reinhold Kneer
- 2 Institute of Heat and Mass Transfer, RWTH Aachen University , Aachen, Germany
| | - Stefan Jockenhoevel
- 1 Department of Tissue Engineering and Textile Implants, Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University , Aachen, Germany .,3 Aachen-Maastricht Institute for Biobased Materials, Maastricht University at Chemelot Campus , Geleen, The Netherlands
| | - Christian Gabriel Cornelissen
- 1 Department of Tissue Engineering and Textile Implants, Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University , Aachen, Germany .,4 Section for Pneumology, Department for Internal Medicine, RWTH Aachen University , Aachen, Germany
| |
Collapse
|