1
|
Zhang B, Bottenus N, Jin FQ, Nightingale KR. Quantifying the Impact of Imaging Through Body Walls on Shear Wave Elasticity Measurements. ULTRASOUND IN MEDICINE & BIOLOGY 2023; 49:734-749. [PMID: 36564217 PMCID: PMC9908830 DOI: 10.1016/j.ultrasmedbio.2022.10.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/01/2022] [Revised: 09/21/2022] [Accepted: 10/05/2022] [Indexed: 06/17/2023]
Abstract
In the context of ultrasonic hepatic shear wave elasticity imaging (SWEI), measurement success has been determined to increase when using elevated acoustic output pressures. As SWEI sequences consist of two distinct operations (pushing and tracking), acquisition failures could be attributed to (i) insufficient acoustic radiation force generation resulting in inadequate shear wave amplitude and/or (ii) distorted ultrasonic tissue motion tracking. In the study described here, an opposing window experimental setup that isolated body wall effects separately between the push and track SWEI operations was implemented. A commonly employed commercial track configuration was used, harmonic multiple-track-location SWEI. The effects of imaging through body walls on the pushing and tracking operations of SWEI as a function of mechanical index (MI), spanning 5 different push beam MIs and 10 track beam MIs, were independently assessed using porcine body walls. Shear wave speed yield was found to increase with both increasing push and track MI. Although not consistent across all samples, measurements in a subset of body walls were found to be signal limited during tracking and to increase yield by up to 35% when increasing electronic signal-to-noise ratio by increasing harmonic track transmit pressure.
Collapse
Affiliation(s)
- Bofeng Zhang
- Department of Biomedical Engineering, Duke University, Durham, North Carolina, USA.
| | - Nick Bottenus
- Department of Mechanical Engineering, University of Colorado Boulder, Boulder, Colorado, USA
| | - Felix Q Jin
- Department of Biomedical Engineering, Duke University, Durham, North Carolina, USA
| | | |
Collapse
|
2
|
Foiret J, Cai X, Bendjador H, Park EY, Kamaya A, Ferrara KW. Improving plane wave ultrasound imaging through real-time beamformation across multiple arrays. Sci Rep 2022; 12:13386. [PMID: 35927389 PMCID: PMC9352764 DOI: 10.1038/s41598-022-16961-2] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2021] [Accepted: 07/19/2022] [Indexed: 11/09/2022] Open
Abstract
Ultrasound imaging is a widely used diagnostic tool but has limitations in the imaging of deep lesions or obese patients where the large depth to aperture size ratio (f-number) reduces image quality. Reducing the f-number can improve image quality, and in this work, we combined three commercial arrays to create a large imaging aperture of 100 mm and 384 elements. To maintain the frame rate given the large number of elements, plane wave imaging was implemented with all three arrays transmitting a coherent wavefront. On wire targets at a depth of 100 mm, the lateral resolution is significantly improved; the lateral resolution was 1.27 mm with one array (1/3 of the aperture) and 0.37 mm with the full aperture. After creating virtual receiving elements to fill the inter-array gaps, an autoregressive filter reduced the grating lobes originating from the inter-array gaps by - 5.2 dB. On a calibrated commercial phantom, the extended field-of-view and improved spatial resolution were verified. The large aperture facilitates aberration correction using a singular value decomposition-based beamformer. Finally, after approval of the Stanford Institutional Review Board, the three-array configuration was applied in imaging the liver of a volunteer, validating the potential for enhanced resolution.
Collapse
Affiliation(s)
| | - Xiran Cai
- Stanford University, Palo Alto, CA, USA
| | | | | | | | | |
Collapse
|
3
|
Zhang B, Pinton GF, Nightingale KR. On the Relationship between Spatial Coherence and In Situ Pressure for Abdominal Imaging. ULTRASOUND IN MEDICINE & BIOLOGY 2021; 47:2310-2320. [PMID: 33985826 PMCID: PMC8494065 DOI: 10.1016/j.ultrasmedbio.2021.03.008] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/03/2020] [Revised: 03/11/2021] [Accepted: 03/12/2021] [Indexed: 05/25/2023]
Abstract
Tissue harmonic signal quality has been shown to improve with elevated acoustic pressure. The peak rarefaction pressure (PRP) for a given transmit, however, is limited by the Food and Drug Administration guidelines for mechanical index. We have previously demonstrated that the mechanical index overestimates in situ PRP for tightly focused beams in vivo, due primarily to phase aberration. In this study, we evaluate two spatial coherence-based image quality metrics-short-lag spatial coherence and harmonic short-lag spatial coherence-as proxy estimates for phase aberration and assess their correlation with in situ PRP in simulations and experiments when imaging through abdominal body walls. We demonstrate strong correlation between both spatial coherence-based metrics and in situ PRP (R2 = 0.77 for harmonic short-lag spatial coherence, R2 = 0.67 for short-lag spatial coherence), an observation that could be leveraged in the future for patient-specific selection of acoustic output.
Collapse
Affiliation(s)
- Bofeng Zhang
- Department of Biomedical Engineering, Duke University, Durham, North Carolina, USA.
| | - Gianmarco F Pinton
- Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill and North Carolina State University, Chapel Hill, North Carolina, USA
| | | |
Collapse
|
4
|
Peralta L, Ramalli A, Reinwald M, Eckersley RJ, Hajnal JV. Impact of Aperture, Depth, and Acoustic Clutter on the Performance of Coherent Multi-Transducer Ultrasound Imaging. APPLIED SCIENCES-BASEL 2020; 10:7655. [PMID: 33680504 PMCID: PMC7116862 DOI: 10.3390/app10217655] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Transducers with a larger aperture size are desirable in ultrasound imaging to improve resolution and image quality. A coherent multi-transducer ultrasound imaging system (CoMTUS) enables an extended effective aperture through the coherent combination of multiple transducers. In this study, the discontinuous extended aperture created by CoMTUS and its performance for deep imaging and through layered media are investigated by both simulations and experiments. Typical image quality metrics—resolution, contrast and contrast-to-noise ratio—are evaluated and compared with a standard single probe imaging system. Results suggest that the image performance of CoMTUS depends on the relative spatial location of the arrays. The resulting effective aperture significantly improves resolution, while the separation between the arrays may degrade contrast. For a limited gap in the effective aperture (less than a few centimetres), CoMTUS provides benefits to image quality compared to the standard single probe imaging system. Overall, CoMTUS shows higher sensitivity and reduced loss of resolution with imaging depth. In general, CoMTUS imaging performance was unaffected when imaging through a layered medium with different speed of sound values and resolution improved up to 80% at large imaging depths.
Collapse
Affiliation(s)
- Laura Peralta
- Department of Biomedical Engineering, School of Biomedical Engineering & Imaging Sciences, King’s College London, London SE1 7EH, UK
- Correspondence:
| | - Alessandro Ramalli
- Department of Information Engineering, University of Florence, 50139 Florence, Italy
| | - Michael Reinwald
- Department of Biomedical Engineering, School of Biomedical Engineering & Imaging Sciences, King’s College London, London SE1 7EH, UK
| | - Robert J. Eckersley
- Department of Biomedical Engineering, School of Biomedical Engineering & Imaging Sciences, King’s College London, London SE1 7EH, UK
| | - Joseph V. Hajnal
- Department of Biomedical Engineering, School of Biomedical Engineering & Imaging Sciences, King’s College London, London SE1 7EH, UK
| |
Collapse
|
5
|
Peralta L, Gomez A, Luan Y, Kim BH, Hajnal JV, Eckersley RJ. Coherent Multi-Transducer Ultrasound Imaging. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2019; 66:1316-1330. [PMID: 31180847 PMCID: PMC7115943 DOI: 10.1109/tuffc.2019.2921103] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
This work extends the effective aperture size by coherently compounding the received radio frequency data from multiple transducers. As a result, it is possible to obtain an improved image, with enhanced resolution, an extended field of view (FoV), and high-acquisition frame rates. A framework is developed in which an ultrasound imaging system consisting of N synchronized matrix arrays, each with partly shared FoV, take turns to transmit plane waves (PWs). Only one individual transducer transmits at each time while all N transducers simultaneously receive. The subwavelength localization accuracy required to combine information from multiple transducers is achieved without the use of any external tracking device. The method developed in this study is based on the study of the backscattered echoes received by the same transducer and resulting from a targeted scatterer point in the medium insonated by the multiple ultrasound probes of the system. The current transducer locations along with the speed of sound in the medium are deduced by optimizing the cross correlation between these echoes. The method is demonstrated experimentally in 2-D for two linear arrays using point targets and anechoic lesion phantoms. The first demonstration of a free-hand experiment is also shown. Results demonstrate that the coherent multi-transducer ultrasound imaging method has the potential to improve ultrasound image quality, improving resolution, and target detectability. Compared with coherent PW compounding using a single probe, lateral resolution improved from 1.56 to 0.71 mm in the coherent multi-transducer imaging method without acquisition frame rate sacrifice (acquisition frame rate 5350 Hz).
Collapse
|
6
|
Bottenus N, Long W, Morgan M, Trahey G. Evaluation of Large-Aperture Imaging Through the ex Vivo Human Abdominal Wall. ULTRASOUND IN MEDICINE & BIOLOGY 2018; 44:687-701. [PMID: 29249458 PMCID: PMC5801112 DOI: 10.1016/j.ultrasmedbio.2017.10.019] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/23/2017] [Revised: 10/25/2017] [Accepted: 10/31/2017] [Indexed: 05/06/2023]
Abstract
Current clinical abdominal imaging arrays are designed to maximize angular field of view rather than the extent of the coherent aperture. We illustrate, in ex vivo experiments, the use of a large effective aperture to perform high-resolution imaging, even in the presence of abdominal wall-induced acoustic clutter and aberration. Point and lesion phantom targets were imaged through a water path and through three excised cadaver abdominal walls to create different clinically relevant clutter effects with matched imaging targets. A 7.36-cm effective aperture was used to image the targets at a depth of 6.4 cm, and image quality metrics were measured over a range of aperture sizes using synthetic aperture techniques. In all three cases, although degradation compared with the control was observed, lateral resolution improved with increasing aperture size without loss of contrast. Spatial compounding of the large-aperture data drastically improved lesion detectability and produced contrast-to-noise ratio improvements of 83%-106% compared with the large coherent aperture. These studies indicate the need for the development of large arrays for high-resolution abdominal diagnostic imaging.
Collapse
Affiliation(s)
- Nick Bottenus
- Department of Biomedical Engineering, Duke University, Durham, North Carolina, USA.
| | - Will Long
- Department of Biomedical Engineering, Duke University, Durham, North Carolina, USA
| | - Matthew Morgan
- Department of Biomedical Engineering, Duke University, Durham, North Carolina, USA
| | - Gregg Trahey
- Department of Biomedical Engineering, Duke University, Durham, North Carolina, USA; Department of Radiology, Duke University, Durham, North Carolina, USA
| |
Collapse
|
7
|
Deng Y, Palmeri ML, Rouze NC, Haystead CM, Nightingale KR. Evaluating the Benefit of Elevated Acoustic Output in Harmonic Motion Estimation in Ultrasonic Shear Wave Elasticity Imaging. ULTRASOUND IN MEDICINE & BIOLOGY 2018; 44:303-310. [PMID: 29169880 PMCID: PMC5743577 DOI: 10.1016/j.ultrasmedbio.2017.10.003] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/26/2017] [Revised: 10/02/2017] [Accepted: 10/03/2017] [Indexed: 05/03/2023]
Abstract
Harmonic imaging techniques have been applied in ultrasonic elasticity imaging to obtain higher-quality tissue motion tracking data. However, harmonic tracking can be signal-to-noise ratio and penetration depth limited during clinical imaging, resulting in decreased yield of successful shear wave speed measurements. A logical approach is to increase the source pressure, but the in situ pressures used in diagnostic ultrasound have been subject to a de facto upper limit based on the Food and Drug Administration guideline for the mechanical index (MI <1.9). A recent American Institute of Ultrasound in Medicine report concluded that an in situ MI up to 4.0 could be warranted without concern for increased risk of cavitation in non-fetal tissues without gas bodies if there were a concurrent clinical benefit. This work evaluates the impact of using an elevated MI in harmonic motion tracking for hepatic shear wave elasticity imaging. The studies indicate that high-MI harmonic tracking increased shear wave speed estimation yield by 27% at a focal depth of 5 cm, with larger yield increase in more difficult-to-image patients. High-MI tracking improved harmonic tracking data quality by increasing the signal-to-noise ratio and decreasing jitter in the tissue motion data. We conclude that there is clinical benefit to use of elevated acoustic output in shear wave tracking, particularly in difficult-to-image patients.
Collapse
Affiliation(s)
- Yufeng Deng
- Department of Biomedical Engineering, Duke University, Durham, North Carolina.
| | - Mark L Palmeri
- Department of Biomedical Engineering, Duke University, Durham, North Carolina
| | - Ned C Rouze
- Department of Biomedical Engineering, Duke University, Durham, North Carolina
| | - Clare M Haystead
- Department of Radiology, Duke University Medical Center, Durham, North Carolina
| | | |
Collapse
|
8
|
Deng Y, Palmeri ML, Rouze NC, Trahey GE, Haystead CM, Nightingale KR. Quantifying Image Quality Improvement Using Elevated Acoustic Output in B-Mode Harmonic Imaging. ULTRASOUND IN MEDICINE & BIOLOGY 2017; 43:2416-2425. [PMID: 28755792 PMCID: PMC5580090 DOI: 10.1016/j.ultrasmedbio.2017.06.024] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/20/2017] [Revised: 06/01/2017] [Accepted: 06/20/2017] [Indexed: 05/03/2023]
Abstract
Tissue harmonic imaging has been widely used in abdominal imaging because of its significant reduction in acoustic noise compared with fundamental imaging. However, tissue harmonic imaging can be limited by both signal-to-noise ratio and penetration depth during clinical imaging, resulting in decreased diagnostic utility. A logical approach would be to increase the source pressure, but the in situ pressures used in diagnostic ultrasound are subject to a de facto upper limit based on the U.S. Food and Drug Administration guideline for the mechanical index (<1.9). A recent American Institute of Ultrasound in Medicine report concluded that an effective mechanical index ≤4.0 could be warranted without concern for increased risk of cavitation in non-fetal tissues without gas bodies, but would only be justified if there were a concurrent improvement in image quality and diagnostic utility. This work evaluates image quality differences between normal and elevated acoustic output hepatic harmonic imaging using a transmit frequency of 1.8 MHz. The results indicate that harmonic imaging using elevated acoustic output leads to modest improvements (3%-7%) in contrast-to-noise ratio of hypo-echoic hepatic vessels and increases in imaging penetration depth on the order of 4 mm per mechanical index increase of 0.1 for a given focal depth. Difficult-to-image patients who suffer from poor ultrasound image quality exhibited larger improvements than easy-to-image study participants.
Collapse
Affiliation(s)
- Yufeng Deng
- Department of Biomedical Engineering, Duke University, Durham, North Carolina, USA.
| | - Mark L Palmeri
- Department of Biomedical Engineering, Duke University, Durham, North Carolina, USA
| | - Ned C Rouze
- Department of Biomedical Engineering, Duke University, Durham, North Carolina, USA
| | - Gregg E Trahey
- Department of Biomedical Engineering, Duke University, Durham, North Carolina, USA; Department of Radiology, Duke University Medical Center, Durham, North Carolina, USA
| | - Clare M Haystead
- Department of Radiology, Duke University Medical Center, Durham, North Carolina, USA
| | | |
Collapse
|