1
|
Donaldson LE, Vogrin S, So M, Ward GM, Krishnamurthy B, Sundararajan V, MacIsaac RJ, Kay TW, McAuley SA. Continuous glucose monitoring-based composite metrics: a review and assessment of performance in recent-onset and long-duration type 1 diabetes. Diabetes Technol Ther 2023. [PMID: 37010375 DOI: 10.1089/dia.2022.0563] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 04/04/2023]
Abstract
This study examined correlations between continuous glucose monitoring (CGM)-based composite metrics and standard glucose metrics within CGM data sets from individuals with recent-onset and long-duration type 1 diabetes. First, a literature review and critique of published CGM-based composite metrics was undertaken. Second, composite metric results were calculated for the two CGM data sets and correlations with six standard glucose metrics were examined. Fourteen composite metrics met selection criteria; these metrics focused on overall glycemia (n = 8), glycemic variability (n = 4), and hypoglycemia (n = 2), respectively. Results for the two diabetes cohorts were similar. All eight metrics focusing on overall glycemia strongly correlated with glucose time in range; none strongly correlated with time below range. The eight overall glycemia-focused and two hypoglycemia-focused composite metrics were all sensitive to automated insulin delivery therapeutic intervention. Until a composite metric can adequately capture both achieved target glycemia and hypoglycemia burden, the current two-dimensional CGM assessment approach may offer greatest clinical utility.
Collapse
Affiliation(s)
- Laura E Donaldson
- The University of Melbourne, 2281, Department of Medicine, Melbourne, Victoria, Australia
- St Vincent's Hospital Melbourne Pty Ltd, 60078, Department of Endocrinology & Diabetes, Melbourne, Victoria, Australia;
| | - Sara Vogrin
- The University of Melbourne, 2281, Department of Medicine, Melbourne, Victoria, Australia;
| | - Michelle So
- St Vincent's Institute of Medical Research, 85092, Melbourne, Victoria, Australia
- The Royal Melbourne Hospital, 90134, Department of Diabetes and Endocrinology, Parkville, Victoria, Australia
- Northern Health NCHER, 569275, Department of Endocrinology and Diabetes, Melbourne, Victoria, Australia;
| | - Glenn M Ward
- The University of Melbourne, 2281, Department of Medicine, Melbourne, Victoria, Australia
- St Vincent's Hospital Melbourne Pty Ltd, 60078, Department of Endocrinology & Diabetes, Melbourne, Victoria, Australia;
| | - Balasubramanian Krishnamurthy
- The University of Melbourne, 2281, Department of Medicine, Melbourne, Victoria, Australia
- St Vincent's Institute of Medical Research, 85092, Melbourne, Victoria, Australia;
| | - Vijaya Sundararajan
- The University of Melbourne, 2281, Department of Medicine, Melbourne, Victoria, Australia;
| | - Richard J MacIsaac
- The University of Melbourne, 2281, Department of Medicine, Melbourne, Victoria, Australia
- St Vincent's Hospital Melbourne Pty Ltd, 60078, Department of Endocrinology & Diabetes, Melbourne, Victoria, Australia;
| | - Thomas Wh Kay
- St Vincent's Institute of Medical Research, 85092, Melbourne, Victoria, Australia;
| | - Sybil A McAuley
- The University of Melbourne, 2281, Department of Medicine, Melbourne, Victoria, Australia
- St Vincent's Hospital Melbourne Pty Ltd, 60078, Department of Endocrinology & Diabetes, Melbourne, Victoria, Australia;
| |
Collapse
|
2
|
Moscardó V, Giménez M, Oliver N, Hill NR. Updated Software for Automated Assessment of Glucose Variability and Quality of Glycemic Control in Diabetes. Diabetes Technol Ther 2020; 22:701-708. [PMID: 32195607 PMCID: PMC7591379 DOI: 10.1089/dia.2019.0416] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Abstract
Background: Glycemic variability is an important factor to consider in diabetes management. It can be assessed with multiple glycemic variability metrics and quality of control indices based on continuous glucose monitoring (CGM) recordings. For this, a robust repeatable calculation is important. A widely used tool for automated assessment is the EasyGV software. The aim of this work is to implement new methods of glycemic variability assessment in EasyGV and to validate implementation of each glucose metric in EasyGV against a reference implementation of the calculations. Methods: Validation data used came from the JDRF CGM study. Validation of the implementation of metrics that are available in EasyGV software v9 was carried out and the following new methods were added and validated: personal glycemic state, index of glycemic control, times in ranges, and glycemic variability percentage. Reference values considered gold standard calculations were derived from MATLAB implementation of each metric. Results: The Pearson correlation coefficient was above 0.98 for all metrics, except for mean amplitude of glycemic excursion (r = 0.87) as EasyGV implements a fuzzy logic approach to assessment of variability. Bland-Altman plots demonstrated validation of the new software. Conclusions: The new freely available EasyGV software v10 (www.phc.ox.ac.uk/research/technology-outputs/easygv) is a validated robust tool for analyzing different glycemic variabilities and control metrics.
Collapse
Affiliation(s)
- Vanessa Moscardó
- Instituto Universitario de Automática e Informática Industrial, Universitat Politècnica de València, València, Spain
| | - Marga Giménez
- Diabetes Unit, Endocrinology and Nutrition Department, Hospital Clínic Universitari, IDIBAPS, Barcelona, Spain
| | - Nick Oliver
- Department of Metabolism, Digestion and Reproduction, Faculty of Medicine, Imperial College London, United Kingdom
- Address correspondence to: Nick Oliver, FRCP, Department of Metabolism, Digestion and Reproduction, Faculty of Medicine, Imperial College London, St. Mary's Campus, Norfolk Place, W2 1PG London, United Kingdom
| | - Nathan R. Hill
- Harris Manchester College, Mansfield Road, University of Oxford, Oxford, United Kingdom
| |
Collapse
|
3
|
Dai X, Luo ZC, Zhai L, Zhao WP, Huang F. Artificial Pancreas as an Effective and Safe Alternative in Patients with Type 1 Diabetes Mellitus: A Systematic Review and Meta-Analysis. Diabetes Ther 2018; 9:1269-1277. [PMID: 29744820 PMCID: PMC5984939 DOI: 10.1007/s13300-018-0436-y] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/13/2018] [Indexed: 12/13/2022] Open
Abstract
INTRODUCTION Insulin injection is the main treatment in patients with type 1 diabetes mellitus (T1DM). Even though continuous glucose monitoring has significantly improved the conditions of these patients, limitations still exist. To further enhance glucose control in patients with T1DM, an artificial pancreas has been developed. We aimed to systematically compare artificial pancreas with its control group during a 24-h basis in patients with T1DM. METHODS Electronic databases were carefully searched for English publications comparing artificial pancreas with its control group. Overall daytime and nighttime glucose parameters were considered as the endpoints. Data were evaluated by means of weighted mean differences (WMDs) and 95% confidence intervals (CIs) generated by RevMan 5.3 software. RESULTS A total number of 354 patients were included. Artificial pancreas significantly maintained a better mean concentration of glucose (WMD - 1.03, 95% CI - 1.32 to - 0.75; P = 0.00001). Time spent in the hypoglycemic phase was also significantly lower (WMD - 1.23, 95% CI - 1.56 to - 0.91; P = 0.00001). Daily insulin requirement also significantly favored artificial pancreas (WMD - 3.43, 95% CI - 4.27 to - 2.59; P = 0.00001). Time spent outside the euglycemic phase and hyperglycemia phase (glucose > 10.0 mmol/L) also significantly favored artificial pancreas. Also, the numbers of hypoglycemic events were not significantly different. CONCLUSION Artificial pancreas might be considered an effective and safe alternative to be used during a 24-h basis in patients with T1DM.
Collapse
Affiliation(s)
- Xia Dai
- Department of Endocrinology, The First Affiliated Hospital of Guangxi Medical University, Nanning, 530021, Guangxi, People's Republic of China
| | - Zu-Chun Luo
- Department of Internal Medicine Education, The First Affiliated Hospital of Guangxi Medical University, Nanning, 530021, Guangxi, People's Republic of China
| | - Lu Zhai
- Department of Endocrinology, The First Affiliated Hospital of Guangxi Medical University, Nanning, 530021, Guangxi, People's Republic of China
| | - Wen-Piao Zhao
- Department of Endocrinology, The First Affiliated Hospital of Guangxi Medical University, Nanning, 530021, Guangxi, People's Republic of China
| | - Feng Huang
- Institute of Cardiovascular Diseases and Guangxi Key Laboratory Base of Precision Medicine in Cardio-cerebrovascular Diseases Control and Prevention, The First Affiliated Hospital of Guangxi Medical University, Nanning, Guangxi, 530021, People's Republic of China.
| |
Collapse
|
4
|
Abstract
Glycemic variability (GV) is a major consideration when evaluating quality of glycemic control. GV increases progressively from prediabetes through advanced T2D and is still higher in T1D. GV is correlated with risk of hypoglycemia. The most popular metrics for GV are the %Coefficient of Variation (%CV) and standard deviation (SD). The %CV is correlated with risk of hypoglycemia. Graphical display of glucose by date, time of day, and day of the week, and display of simplified glucose distributions showing % of time in several ranges, provide clinically useful indicators of GV. SD is highly correlated with most other measures of GV, including interquartile range, mean amplitude of glycemic excursion, mean of daily differences, and average daily risk range. Some metrics are sensitive to the frequency, periodicity, and complexity of glycemic fluctuations, including Fourier analysis, periodograms, frequency spectrum, multiscale entropy (MSE), and Glucose Variability Percentage (GVP). Fourier analysis indicates progressive changes from normal subjects to children and adults with T1D, and from prediabetes to T2D. The GVP identifies novel characteristics for children, adolescents, and adults with type 1 diabetes and for adults with type 2. GVP also demonstrated small rapid glycemic fluctuations in people with T1D when using a dual-hormone closed-loop control. MSE demonstrated systematic changes from normal subjects to people with T2D at various stages of duration, intensity of therapy, and quality of glycemic control. We describe new metrics to characterize postprandial excursions, day-to-day stability of glucose patterns, and systematic changes of patterns by day of the week. Metrics for GV should be interpreted in terms of percentiles and z-scores relative to identified reference populations. There is a need for large accessible databases for reference populations to provide a basis for automated interpretation of GV and other features of continuous glucose monitoring records.
Collapse
Affiliation(s)
- David Rodbard
- Biomedical Informatics Consultants LLC , Potomac, Maryland
| |
Collapse
|
5
|
Rodbard D. Metrics to Evaluate Quality of Glycemic Control: Comparison of Time in Target, Hypoglycemic, and Hyperglycemic Ranges with "Risk Indices". Diabetes Technol Ther 2018; 20:325-334. [PMID: 29792750 DOI: 10.1089/dia.2017.0416] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
OBJECTIVE We sought to cross validate several metrics for quality of glycemic control, hypoglycemia, and hyperglycemia. RESEARCH DESIGN AND METHODS We analyzed the mathematical properties of several metrics for overall glycemic control, and for hypo- and hyperglycemia, to evaluate their similarities, differences, and interrelationships. We used linear regression to describe interrelationships and examined correlations between metrics within three conceptual groups. RESULTS There were consistently high correlations between %Time in range (%TIR) and previously described risk indices (M100, Blood Glucose Risk Index [BGRI], Glycemic Risk Assessment Diabetes Equation [GRADE], Index of Glycemic Control [IGC]), and with J-Index (J). There were also high correlations among %Hypoglycemia, Low Blood Glucose Index (LBGI), percentage of GRADE attributable to hypoglycemia (GRADE%Hypoglycemia), and Hypoglycemia Index, but negligible correlation with J. There were high correlations of percentage of time in hyperglycemic range (%Hyperglycemia) with High Blood Glucose Index (HBGI), percentage of GRADE attributable to hyperglycemia (GRADE%Hyperglycemia), Hyperglycemia Index, and J. %TIR is highly negatively correlated with %Hyperglycemia but very weakly correlated with %Hypoglycemia. By adjusting the parameters used in IGC, Hypoglycemia Index, Hyperglycemia Index, or in MR, one can more closely approximate the properties of BGRI, LBGI, or HBGI, and of GRADE, GRADE%Hypoglycemia, or GRADE%Hyperglycemia. CONCLUSIONS Simple readily understandable criteria such as %TIR, %Hypoglycemia, and %Hyperglycemia are highly correlated with and appear to be as informative as "risk indices." The J-Index is sensitive to hyperglycemia but insensitive to hypoglycemia.
Collapse
Affiliation(s)
- David Rodbard
- Biomedical Informatics Consultants LLC , Potomac, Maryland
| |
Collapse
|
6
|
Peyser TA, Balo AK, Buckingham BA, Hirsch IB, Garcia A. Glycemic Variability Percentage: A Novel Method for Assessing Glycemic Variability from Continuous Glucose Monitor Data. Diabetes Technol Ther 2018; 20:6-16. [PMID: 29227755 PMCID: PMC5846572 DOI: 10.1089/dia.2017.0187] [Citation(s) in RCA: 53] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
BACKGROUND High levels of glycemic variability are still observed in most patients with diabetes with severe insulin deficiency. Glycemic variability may be an important risk factor for acute and chronic complications. Despite its clinical importance, there is no consensus on the optimum method for characterizing glycemic variability. METHOD We developed a simple new metric, the glycemic variability percentage (GVP), to assess glycemic variability by analyzing the length of the continuous glucose monitoring (CGM) temporal trace normalized to the duration under evaluation. The GVP is similar to other recently proposed glycemic variability metrics, the distance traveled, and the mean absolute glucose (MAG) change. We compared results from distance traveled, MAG, GVP, standard deviation (SD), and coefficient of variation (CV) applied to simulated CGM traces accentuating the difference between amplitude and frequency of oscillations. The GVP metric was also applied to data from clinical studies for the Dexcom G4 Platinum CGM in subjects without diabetes, with type 2 diabetes, and with type 1 diabetes (adults, adolescents, and children). RESULTS In contrast to other metrics, such as CV and SD, the distance traveled, MAG, and GVP all captured both the amplitude and frequency of glucose oscillations. The GVP metric was also able to differentiate between diabetic and nondiabetic subjects and between subjects with diabetes with low, moderate, and high glycemic variability based on interquartile analysis. CONCLUSION A new metric for the assessment of glycemic variability has been shown to capture glycemic variability due to fluctuations in both the amplitude and frequency of glucose given by CGM data.
Collapse
Affiliation(s)
| | | | - Bruce A. Buckingham
- Department of Pediatric Endocrinology, Stanford University, Stanford, California
| | - Irl B. Hirsch
- Department of Medicine, Division of Metabolism, Endocrinology and Nutrition, University of Washington, Seattle, Washington
| | | |
Collapse
|