Li C, Marton I, Harari D, Shemesh M, Kalchenko V, Pardo M, Schreiber G, Rudich Y. Gelatin Stabilizes Nebulized Proteins in Pulmonary Drug Delivery against COVID-19. ACS Biomater Sci Eng 2022; 8:2553-2563. [PMID: 35608934 PMCID: PMC9159517 DOI: 10.1021/acsbiomaterials.2c00419] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2022] [Accepted: 05/05/2022] [Indexed: 11/28/2022]
Abstract
Delivering medication to the lungs via nebulization of pharmaceuticals is a noninvasive and efficient therapy route, particularly for respiratory diseases. The recent worldwide severe acute respiratory syndrome coronavirus type 2 (SARS-CoV-2) pandemic urges the development of such therapies as an effective alternative to vaccines. The main difficulties in using inhalation therapy are the development of effective medicine and methods to stabilize the biological molecules and transfer them to the lungs efficiently following nebulization. We have developed a high-affinity angiotensin-converting enzyme 2 (ACE2) receptor-binding domain (RBD-62) that can be used as a medication to inhibit infection with SARS-CoV-2 and its variants. In this study, we established a nebulization protocol for drug delivery by inhalation using two commercial vibrating mesh (VM) nebulizers (Aerogen Solo and PARI eFlow) that generate similar mist size distribution in a size range that allows efficient deposition in the small respiratory airway. In a series of experiments, we show the high activity of RBD-62, interferon-α2 (IFN-α2), and other proteins following nebulization. The addition of gelatin significantly stabilizes the proteins and enhances the fractions of active proteins after nebulization, minimizing the medication dosage. Furthermore, hamster inhalation experiments verified the feasibility of the protocol in pulmonary drug delivery. In short, the gelatin-modified RBD-62 formulation in coordination with VM nebulizer can be used as a therapy to cure SARS-CoV-2.
Collapse
Affiliation(s)
- Chunlin Li
- Department
of Earth and Planetary Sciences, Weizmann
Institute of Science, Rehovot 76100, Israel
| | - Ira Marton
- Department
of Earth and Planetary Sciences, Weizmann
Institute of Science, Rehovot 76100, Israel
- Department
of Biomolecular Sciences, Weizmann Institute
of Science, Rehovot 76100, Israel
| | - Daniel Harari
- Department
of Biomolecular Sciences, Weizmann Institute
of Science, Rehovot 76100, Israel
| | - Maya Shemesh
- Department
of Biomolecular Sciences, Weizmann Institute
of Science, Rehovot 76100, Israel
| | - Vyacheslav Kalchenko
- Department
of Veterinary Resources, Weizmann Institute
of Science, Rehovot 76100, Israel
| | - Michal Pardo
- Department
of Earth and Planetary Sciences, Weizmann
Institute of Science, Rehovot 76100, Israel
| | - Gideon Schreiber
- Department
of Biomolecular Sciences, Weizmann Institute
of Science, Rehovot 76100, Israel
| | - Yinon Rudich
- Department
of Earth and Planetary Sciences, Weizmann
Institute of Science, Rehovot 76100, Israel
| |
Collapse
|
2
|
Optimizing Antimicrobial Drug Dosing in Critically Ill Patients. Microorganisms 2021; 9:microorganisms9071401. [PMID: 34203510 PMCID: PMC8305961 DOI: 10.3390/microorganisms9071401] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2021] [Revised: 06/25/2021] [Accepted: 06/25/2021] [Indexed: 12/23/2022] Open
Abstract
A fundamental step in the successful management of sepsis and septic shock is early empiric antimicrobial therapy. However, for this to be effective, several decisions must be addressed simultaneously: (1) antimicrobial choices should be adequate, covering the most probable pathogens; (2) they should be administered in the appropriate dose, (3) by the correct route, and (4) using the correct mode of administration to achieve successful concentration at the infection site. In critically ill patients, antimicrobial dosing is a common challenge and a frequent source of errors, since these patients present deranged pharmacokinetics, namely increased volume of distribution and altered drug clearance, which either increased or decreased. Moreover, the clinical condition of these patients changes markedly over time, either improving or deteriorating. The consequent impact on drug pharmacokinetics further complicates the selection of correct drug schedules and dosing during the course of therapy. In recent years, the knowledge of pharmacokinetics and pharmacodynamics, drug dosing, therapeutic drug monitoring, and antimicrobial resistance in the critically ill patients has greatly improved, fostering strategies to optimize therapeutic efficacy and to reduce toxicity and adverse events. Nonetheless, delivering adequate and appropriate antimicrobial therapy is still a challenge, since pathogen resistance continues to rise, and new therapeutic agents remain scarce. We aim to review the available literature to assess the challenges, impact, and tools to optimize individualization of antimicrobial dosing to maximize exposure and effectiveness in critically ill patients.
Collapse
|
3
|
Harb HS, Saeed H, Madney YM, Abdelrahman MA, Osama H, Esquinas AM, Abdelrahim ME. Update efficacy of aerosol therapy with noninvasive ventilator approach (non-invasive ventilation and nasal high flow). J Drug Deliv Sci Technol 2020. [DOI: 10.1016/j.jddst.2020.101922] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
4
|
Nebulizer Care and Inhalation Technique in Children with Cystic Fibrosis. CHILDREN-BASEL 2020; 7:children7100153. [PMID: 32992472 PMCID: PMC7600103 DOI: 10.3390/children7100153] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/18/2020] [Revised: 09/08/2020] [Accepted: 09/25/2020] [Indexed: 12/29/2022]
Abstract
Nebulizers are used by the great majority of cystic fibrosis patients for delivery of cornerstone treatments. Inhalation technique and adequate disinfection and maintenance are important for optimizing medication delivery. In this study, inhalation technique and nebulizer disinfection/maintenance were assessed in cystic fibrosis patients by direct observation in clinic and completion of a scoring sheet. A total of 108 patients were recruited. The maximum inhalation technique score was attained by 30.5% and adequate inhalation technique score by 74.08% of patients. The inhalation technique score was best with the vibrating mesh nebulizer (p = 0.038), while patient age and number of nebulized medications did not affect ITS significantly (p > 0.05). Nebulizer disinfection/maintenance score was excellent in only 31.48%. Most families kept the nebulizer clean and used appropriate disinfection method, but only half of them replaced the nebulizer and nebulizer cup at the recommended time intervals. Nebulizer disinfection/maintenance score was positively affected by a number of nebulized medications and negatively by years of equipment use (p = 0.009 and p = 0.001, respectively). Even though inhalation technique and disinfection/maintenance practices were found to be adequate in a large proportion of cases, there is still a need for regular review and education. The type of nebulizer was associated with improved inhalation technique, but more data are required before making specific recommendations.
Collapse
|
5
|
McCarthy SD, González HE, Higgins BD. Future Trends in Nebulized Therapies for Pulmonary Disease. J Pers Med 2020; 10:E37. [PMID: 32397615 PMCID: PMC7354528 DOI: 10.3390/jpm10020037] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2020] [Revised: 05/05/2020] [Accepted: 05/07/2020] [Indexed: 12/15/2022] Open
Abstract
Aerosol therapy is a key modality for drug delivery to the lungs of respiratory disease patients. Aerosol therapy improves therapeutic effects by directly targeting diseased lung regions for rapid onset of action, requiring smaller doses than oral or intravenous delivery and minimizing systemic side effects. In order to optimize treatment of critically ill patients, the efficacy of aerosol therapy depends on lung morphology, breathing patterns, aerosol droplet characteristics, disease, mechanical ventilation, pharmacokinetics, and the pharmacodynamics of cell-drug interactions. While aerosol characteristics are influenced by drug formulations and device mechanisms, most other factors are reliant on individual patient variables. This has led to increased efforts towards more personalized therapeutic approaches to optimize pulmonary drug delivery and improve selection of effective drug types for individual patients. Vibrating mesh nebulizers (VMN) are the dominant device in clinical trials involving mechanical ventilation and emerging drugs. In this review, we consider the use of VMN during mechanical ventilation in intensive care units. We aim to link VMN fundamentals to applications in mechanically ventilated patients and look to the future use of VMN in emerging personalized therapeutic drugs.
Collapse
Affiliation(s)
- Sean D. McCarthy
- Anaesthesia, School of Medicine, National University of Ireland Galway, H91 TK33 Galway, Ireland; (S.D.M.); (H.E.G.)
- Lung Biology Group, Regenerative Medicine Institute (REMEDI) at CÚRAM Centre for Research in Medical Devices, National University of Ireland Galway, H91 TK33 Galway, Ireland
| | - Héctor E. González
- Anaesthesia, School of Medicine, National University of Ireland Galway, H91 TK33 Galway, Ireland; (S.D.M.); (H.E.G.)
- Lung Biology Group, Regenerative Medicine Institute (REMEDI) at CÚRAM Centre for Research in Medical Devices, National University of Ireland Galway, H91 TK33 Galway, Ireland
| | - Brendan D. Higgins
- Physiology, School of Medicine, National University of Ireland Galway, H91 TK33 Galway, Ireland
| |
Collapse
|
6
|
Longest W, Spence B, Hindle M. Devices for Improved Delivery of Nebulized Pharmaceutical Aerosols to the Lungs. J Aerosol Med Pulm Drug Deliv 2019; 32:317-339. [PMID: 31287369 DOI: 10.1089/jamp.2018.1508] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023] Open
Abstract
Nebulizers have a number of advantages for the delivery of inhaled pharmaceutical aerosols, including the use of aqueous formulations and the ability to deliver process-sensitive proteins, peptides, and biological medications. A frequent disadvantage of nebulized aerosols is poor lung delivery efficiency, which wastes valuable medications, increases delivery times, and may increase side effects of the medication. A focus of previous development efforts and previous nebulizer reviews, has been an improvement of the underlying nebulization technology controlling the breakup of a liquid into droplets. However, for a given nebulization technology, a wide range of secondary devices and strategies can be implemented to significantly improve lung delivery efficiency of the aerosol. This review focuses on secondary devices and technologies that can be implemented to improve the lung delivery efficiency of nebulized aerosols and potentially target the region of drug delivery within the lungs. These secondary devices may (1) modify the aerosol size distribution, (2) synchronize aerosol delivery with inhalation, (3) reduce system depositional losses at connection points, (4) improve the patient interface, or (5) guide patient inhalation. The development of these devices and technologies is also discussed, which often includes the use of computational fluid dynamic simulations, three-dimensional printing and rapid prototype device and airway model construction, realistic in vitro experiments, and in vivo analysis. Of the devices reviewed, the implementation of streamlined components may be the most direct and lowest cost approach to enhance aerosol delivery efficiency within nonambulatory nebulizer systems. For applications involving high-dose medications or precise dose administration, the inclusion of active devices to control aerosol size, guide inhalation, and synchronize delivery with inhalation hold considerable promise.
Collapse
Affiliation(s)
- Worth Longest
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, Virginia.,Department of Pharmaceutics, Virginia Commonwealth University, Richmond, Virginia
| | - Benjamin Spence
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, Virginia
| | - Michael Hindle
- Department of Pharmaceutics, Virginia Commonwealth University, Richmond, Virginia
| |
Collapse
|
7
|
Coates A, Culver B, Cockcroft D, Hallstrand T, Haynes J, Kaminsky D, MacIntyre N, Wanger J. Characterizing Nebulizer Performance for Methacholine Challenge Tests. Am J Respir Crit Care Med 2018; 198:988-990. [DOI: 10.1164/rccm.201805-0942ed] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Affiliation(s)
| | | | | | | | | | - David Kaminsky
- University of Vermont College of MedicineBurlington, Vermont
| | | | - Jack Wanger
- Pulmonary Function Testing and Clinical Trials ConsultantRochester, Minnesota
| |
Collapse
|
8
|
Mesh nebulizers have become the first choice for new nebulized pharmaceutical drug developments. Ther Deliv 2018; 9:121-136. [DOI: 10.4155/tde-2017-0102] [Citation(s) in RCA: 59] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
In the 24 years since first being marketed, the mesh nebulizer has been developed by five main manufacturers into a viable solution for the delivery of high-value nebulized drugs. Mesh nebulizers provide increased portability, convenience and energy efficiency along with similar lung deposition and increased ease of use compared with jet nebulizers. An analysis of EU and US clinical trial databases has shown that mesh nebulizers are now preferred over jet nebulizers for clinical trials sponsored by pharmaceutical companies. The results show a strong preference for the use of mesh nebulizers in trials involving high cost and niche therapy areas. Built-in capability to optimize the way patients use their mesh nebulizer and manage their disease will further increase uptake. [Formula: see text]
Collapse
|
9
|
Dugernier J, Ehrmann S, Sottiaux T, Roeseler J, Wittebole X, Dugernier T, Jamar F, Laterre PF, Reychler G. Aerosol delivery during invasive mechanical ventilation: a systematic review. Crit Care 2017; 21:264. [PMID: 29058607 PMCID: PMC5651640 DOI: 10.1186/s13054-017-1844-5] [Citation(s) in RCA: 43] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2017] [Accepted: 09/15/2017] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND This systematic review aimed to assess inhaled drug delivery in mechanically ventilated patients or in animal models. Whole lung and regional deposition and the impact of the ventilator circuit, the artificial airways and the administration technique for aerosol delivery were analyzed. METHODS In vivo studies assessing lung deposition during invasive mechanical ventilation were selected based on a systematic search among four databases. Two investigators independently assessed the eligibility and the risk of bias. RESULTS Twenty-six clinical and ten experimental studies were included. Between 30% and 43% of nominal drug dose was lost to the circuit in ventilated patients. Whole lung deposition of up to 16% and 38% of nominal dose (proportion of drug charged in the device) were reported with nebulizers and metered-dose inhalers, respectively. A penetration index inferior to 1 observed in scintigraphic studies indicated major proximal deposition. However, substantial concentrations of antibiotics were measured in the epithelial lining fluid (887 (406-12,819) μg/mL of amikacin) of infected patients and in sub-pleural specimens (e.g., 197 μg/g of amikacin) dissected from infected piglets, suggesting a significant distal deposition. The administration technique varied among studies and may explain a degree of the variability of deposition that was observed. CONCLUSIONS Lung deposition was lower than 20% of nominal dose delivered with nebulizers and mostly occurred in proximal airways. Further studies are needed to link substantial concentrations of antibiotics in infected pulmonary fluids to pulmonary deposition. The administration technique with nebulizers should be improved in ventilated patients in order to ensure an efficient but safe, feasible and reproducible technique.
Collapse
Affiliation(s)
- Jonathan Dugernier
- Institut de Recherche Expérimentale et Clinique (IREC), Pneumologie, ORL & Dermatologie, Cliniques universitaires Saint-Luc, Avenue Hippocrate 10, 1200, Brussels, Belgium. .,Soins Intensifs, Cliniques universitaires Saint-Luc, Avenue Hippocrate 10, 1200, Brussels, Belgium. .,Médecine Physique, Cliniques universitaires Saint-Luc, Avenue Hippocrate 10, 1200, Brussels, Belgium.
| | - Stephan Ehrmann
- Université François Rabelais, UMR 1100, F-37032, Tours, France.,INSERM, Centre d'étude des Pathologies Respiratoires, UMR 1100, F-37032, Tours, France.,CHRU de Tours, Réanimation polyvalente, F-37044, Tours, France
| | - Thierry Sottiaux
- Soins Intensifs, Clinique Notre-Dame de Grace, Chaussée de Nivelles 212, 6041, Charleroi, Belgium
| | - Jean Roeseler
- Soins Intensifs, Cliniques universitaires Saint-Luc, Avenue Hippocrate 10, 1200, Brussels, Belgium
| | - Xavier Wittebole
- Soins Intensifs, Cliniques universitaires Saint-Luc, Avenue Hippocrate 10, 1200, Brussels, Belgium
| | - Thierry Dugernier
- Soins Intensifs, Clinique Saint-Pierre, Avenue Reine Fabiola 9, 1340, Ottignies, Belgium
| | - François Jamar
- Médecine Nucléaire, Cliniques universitaires Saint-Luc, Avenue Hippocrate 10, 1200, Brussels, Belgium
| | - Pierre-François Laterre
- Soins Intensifs, Cliniques universitaires Saint-Luc, Avenue Hippocrate 10, 1200, Brussels, Belgium
| | - Gregory Reychler
- Institut de Recherche Expérimentale et Clinique (IREC), Pneumologie, ORL & Dermatologie, Cliniques universitaires Saint-Luc, Avenue Hippocrate 10, 1200, Brussels, Belgium.,Médecine Physique, Cliniques universitaires Saint-Luc, Avenue Hippocrate 10, 1200, Brussels, Belgium.,Pneumologie, Cliniques universitaires Saint-Luc, Avenue Hippocrate 10, 1200, Brussels, Belgium
| |
Collapse
|
10
|
Dugernier J, Hesse M, Jumetz T, Bialais E, Roeseler J, Depoortere V, Michotte JB, Wittebole X, Ehrmann S, Laterre PF, Jamar F, Reychler G. Aerosol Delivery with Two Nebulizers Through High-Flow Nasal Cannula: A Randomized Cross-Over Single-Photon Emission Computed Tomography-Computed Tomography Study. J Aerosol Med Pulm Drug Deliv 2017; 30:349-358. [PMID: 28463044 DOI: 10.1089/jamp.2017.1366] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
BACKGROUND High-flow nasal cannula use is developing in ICUs. The aim of this study was to compare aerosol efficiency by using two nebulizers through a high-flow nasal cannula: the most commonly used jet nebulizer (JN) and a more efficient vibrating-mesh nebulizer (VN). METHODS Aerosol delivery of diethylenetriaminepentaacetic acid labeled with technetium-99m (4 mCi/4 mL) to the lungs by using a VN (Aerogen Solo®; Aerogen Ltd., Galway, Ireland) and a constant-output JN (Opti-Mist Plus Nebulizer®; ConvaTec, Bridgewater, NJ) through a high-flow nasal cannula (Optiflow®; Fisher & Paykel, New Zealand) was compared in six healthy subjects. Flow rate was set at 30 L/min through the heated humidified circuit. Pulmonary and extrapulmonary deposition was measured by single-photon emission computed tomography combined with a low-dose computed tomographic scan and by planar scintigraphy. RESULTS Lung deposition was only 3.6 (2.1-4.4) and 1 (0.7-2)% of the nominal dose with the VN and the JN, respectively (p < 0.05). The JN showed higher retained doses than the VN. However, both nebulizers were associated with substantial deposition in the single limb circuit, the humidification chamber, and the nasal cannula [58.2 (51.6-61.6)% of the nominal dose with the VN versus 19.2 (15.8-22.9)% of the nominal dose with the JN, p < 0.05] and in the upper respiratory tract [17.6 (13.4-27.9)% of the nominal dose with the VN and 8.6 (6.0-11.0)% of the nominal dose with the JN, p < 0.05], especially in the nasal cavity. CONCLUSIONS In the specific conditions of the study, pulmonary drug delivery through the high-flow nasal cannula is about 1%-4% of the initial amount of drugs placed in the nebulizer, despite the higher efficiency of the VN as compared with the JN.
Collapse
Affiliation(s)
- Jonathan Dugernier
- 1 Institut de Recherche Expérimentale et Clinique (IREC), Pneumologie, ORL and Dermatologie, Cliniques Universitaires Saint-Luc , Brussels, Belgium .,2 Soins Intensifs, Cliniques Universitaires Saint-Luc , Brussels, Belgium .,3 Médecine Physique, Cliniques Universitaires Saint-Luc , Brussels, Belgium
| | - Michel Hesse
- 4 Médecine Nucléaire, Cliniques Universitaires Saint-Luc , Brussels, Belgium
| | | | - Emilie Bialais
- 1 Institut de Recherche Expérimentale et Clinique (IREC), Pneumologie, ORL and Dermatologie, Cliniques Universitaires Saint-Luc , Brussels, Belgium .,2 Soins Intensifs, Cliniques Universitaires Saint-Luc , Brussels, Belgium .,3 Médecine Physique, Cliniques Universitaires Saint-Luc , Brussels, Belgium
| | - Jean Roeseler
- 2 Soins Intensifs, Cliniques Universitaires Saint-Luc , Brussels, Belgium
| | - Virginie Depoortere
- 4 Médecine Nucléaire, Cliniques Universitaires Saint-Luc , Brussels, Belgium
| | - Jean-Bernard Michotte
- 5 Haute Ecole de Santé Vaud, Filière Physiothérapie, University of Applied Sciences and Arts Western Switzerland , Lausanne, Switzerland
| | - Xavier Wittebole
- 2 Soins Intensifs, Cliniques Universitaires Saint-Luc , Brussels, Belgium
| | - Stephan Ehrmann
- 6 Université François Rabelais , Tours, France .,7 INSERM, Centre d'étude des Pathologies Respiratoires , Tours, France .,8 CHRU de Tours, Réanimation Polyvalente , Tours, France
| | | | - François Jamar
- 4 Médecine Nucléaire, Cliniques Universitaires Saint-Luc , Brussels, Belgium
| | - Gregory Reychler
- 1 Institut de Recherche Expérimentale et Clinique (IREC), Pneumologie, ORL and Dermatologie, Cliniques Universitaires Saint-Luc , Brussels, Belgium .,3 Médecine Physique, Cliniques Universitaires Saint-Luc , Brussels, Belgium .,9 Pneumologie, Cliniques Universitaires Saint-Luc , Brussels, Belgium
| |
Collapse
|
11
|
SPECT-CT Comparison of Lung Deposition using a System combining a Vibrating-mesh Nebulizer with a Valved Holding Chamber and a Conventional Jet Nebulizer: a Randomized Cross-over Study. Pharm Res 2016; 34:290-300. [PMID: 27822851 DOI: 10.1007/s11095-016-2061-7] [Citation(s) in RCA: 39] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2016] [Accepted: 10/27/2016] [Indexed: 12/28/2022]
Abstract
PURPOSE To compare in vivo the total and regional pulmonary deposition of aerosol particles generated by a new system combining a vibrating-mesh nebulizer with a specific valved holding chamber and constant-output jet nebulizer connected to a corrugated tube. METHODS Cross-over study comparing aerosol delivery to the lungs using two nebulizers in 6 healthy male subjects: a vibrating-mesh nebulizer combined with a valved holding chamber (Aerogen Ultra®, Aerogen Ltd., Galway, Ireland) and a jet nebulizer connected to a corrugated tube (Opti-Mist Plus Nebulizer®, ConvaTec, Bridgewater, NJ). Nebulizers were filled with diethylenetriaminepentaacetic acid labelled with technetium-99 m (99mTc-DTPA, 2 mCi/4 mL). Pulmonary deposition of 99mTc-DTPA was measured by single-photon emission computed tomography combined with a low dose CT-scan (SPECT-CT). RESULTS Pulmonary aerosol deposition from SPECT-CT analysis was six times increased with the vibrating-mesh nebulizer as compared to the jet nebulizer (34.1 ± 6.0% versus 5.2 ± 1.1%, p < 0.001). However, aerosol penetration expressed as the three-dimensional normalized ratio of the outer and the inner regions of the lungs was similar between both nebulizers. CONCLUSIONS This study demonstrated the high superiority of the new system combining a vibrating-mesh nebulizer with a valved holding chamber to deliver nebulized particles into the lungs as comparted to a constant-output jet nebulizer with a corrugated tube.
Collapse
|
12
|
Hull J. Lifestyle treatments in cystic fibrosis: The NHS should not pay. Paediatr Respir Rev 2016; 20 Suppl:15-7. [PMID: 27349724 DOI: 10.1016/j.prrv.2016.06.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
Lifestyle treatments can be defined as those which may have in impact on quality of life but do not affect health outcomes. Particular treatment options may be preferred by patients because they are for example, easier to use, take up less time or taste better. The impact on adherence needs to be considered. Treatment options that promote greater adherence to therapy are likely to be more efficacious and so are not, by definition, lifestyle treatments. The NHS is facing unprecedented financial pressure and resources are limited. When lifestyle treatments are more expensive than standard therapy, they should not be funded by the NHS.
Collapse
Affiliation(s)
- Jeremy Hull
- Department of Paediatrics, Level 2, Oxford Children's Hospital, Oxford University Hospitals, Headington, Oxford, OX3 0PQ.
| |
Collapse
|
13
|
Carvalho TC, McConville JT. The function and performance of aqueous aerosol devices for inhalation therapy. ACTA ACUST UNITED AC 2016; 68:556-78. [PMID: 27061412 DOI: 10.1111/jphp.12541] [Citation(s) in RCA: 58] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2015] [Accepted: 02/05/2016] [Indexed: 12/11/2022]
Abstract
OBJECTIVES In this review paper, we explore the interaction between the functioning mechanism of different nebulizers and the physicochemical properties of the formulations for several types of devices, namely jet, ultrasonic and vibrating-mesh nebulizers; colliding and extruded jets; electrohydrodynamic mechanism; surface acoustic wave microfluidic atomization; and capillary aerosol generation. KEY FINDINGS Nebulization is the transformation of bulk liquids into droplets. For inhalation therapy, nebulizers are widely used to aerosolize aqueous systems, such as solutions and suspensions. The interaction between the functioning mechanism of different nebulizers and the physicochemical properties of the formulations plays a significant role in the performance of aerosol generation appropriate for pulmonary delivery. Certain types of nebulizers have consistently presented temperature increase during the nebulization event. Therefore, careful consideration should be given when evaluating thermo-labile drugs, such as protein therapeutics. We also present the general approaches for characterization of nebulizer formulations. SUMMARY In conclusion, the interplay between the dosage form (i.e. aqueous systems) and the specific type of device for aerosol generation determines the effectiveness of drug delivery in nebulization therapies, thus requiring extensive understanding and characterization.
Collapse
Affiliation(s)
- Thiago C Carvalho
- Bristol-Myers Squibb, Drug Product Science & Technology, New Brunswick, NJ, USA
| | - Jason T McConville
- Department of Pharmaceutical Sciences, University of New Mexico, Albuquerque, NM, USA
| |
Collapse
|
14
|
Sawicki GS, Goss CH. Tackling the increasing complexity of CF care. Pediatr Pulmonol 2015; 50 Suppl 40:S74-9. [PMID: 26335957 PMCID: PMC4562023 DOI: 10.1002/ppul.23244] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/15/2015] [Revised: 06/05/2015] [Accepted: 06/16/2015] [Indexed: 12/28/2022]
Abstract
Health outcomes for individuals with cystic fibrosis (CF) have dramatically improved in parallel with better organization of clinical care systems, evolution of novel therapeutics, and improvements in diagnosis and screening for CF and CF-related complications. In parallel with these advances has come an increasing complexity and burden of care, leading to challenges with adherence to treatment regimens. As novel therapeutics continue to be developed and introduced to the CF care regimen, there are clear opportunities to refine and personalize care. This can be done by adding comparative effectiveness research to the CF clinical research paradigm and integrating novel technologies in drug delivery and remote monitoring that can facilitate adherence but also reduce the burden of treatment while maintaining efficacy. This review highlights both the challenges of the increasingly complex treatment regimens in CF and the opportunities to advance care by addressing adherence, implementation science, comparative effectiveness, and integration of novel technologies in CF care.
Collapse
Affiliation(s)
- Gregory S Sawicki
- Division of Respiratory Diseases, Boston Children's Hospital, Boston, Massachusetts
| | - Christopher H Goss
- Division of Pulmonary Medicine, Department of Pediatrics, Seattle Children's Hospital, Seattle, Washington
| |
Collapse
|
15
|
Hertel SP, Winter G, Friess W. Protein stability in pulmonary drug delivery via nebulization. Adv Drug Deliv Rev 2015; 93:79-94. [PMID: 25312674 DOI: 10.1016/j.addr.2014.10.003] [Citation(s) in RCA: 69] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2013] [Revised: 08/22/2014] [Accepted: 10/01/2014] [Indexed: 10/24/2022]
Abstract
Protein inhalation is a delivery route which offers high potential for direct local lung application of proteins. Liquid formulations are usually available in early stages of biopharmaceutical development and nebulizers are the device of choice for atomization avoiding additional process steps like drying and enabling fast progression to clinical trials. While some proteins were proven to remain stable throughout aerosolization e.g. DNase, many biopharmaceuticals are more susceptible towards the stresses encountered during nebulization. The main reason for protein instability is unfolding and aggregation at the air-liquid interface, a problem which is of particular challenge in the case of ultrasound and jet nebulizers due to recirculation of much of the generated droplets. Surfactants are an important formulation component to protect the sensitive biomolecules. A second important challenge is warming of ultrasound and vibrating mesh devices, which can be overcome by overfilling, precooled solutions or cooling of the reservoir. Ultimately, formulation development has to go hand in hand with device evaluation.
Collapse
|
16
|
Ehsan Z, Clancy J. T100: nebulized-concentrated tobramycin formulation for treatment of Pseudomonas aeruginosainfection in cystic fibrosis patients. Expert Opin Orphan Drugs 2015. [DOI: 10.1517/21678707.2015.1064308] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
|
17
|
That’s cool! – Nebulization of thermolabile proteins with a cooled vibrating mesh nebulizer. Eur J Pharm Biopharm 2014; 87:357-65. [DOI: 10.1016/j.ejpb.2014.03.001] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2013] [Revised: 03/04/2014] [Accepted: 03/10/2014] [Indexed: 11/18/2022]
|
18
|
Kamalaporn H, Leung K, Nagel M, Kittanakom S, Calvieri B, Reithmeier RAF, Coates AL. Aerosolized liposomal Amphotericin B: a potential prophylaxis of invasive pulmonary aspergillosis in immunocompromised patients. Pediatr Pulmonol 2014; 49:574-80. [PMID: 23843366 DOI: 10.1002/ppul.22856] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/20/2012] [Accepted: 05/10/2013] [Indexed: 11/08/2022]
Abstract
BACKGROUND Aerosolized liposomal Amphotericin B may reduce the incidence of invasive pulmonary Aspergillosis in adults with chemotherapy-induced prolonged neutropenia with less nephrotoxicity. The breath-actuated AeroEclipse® BAN nebulizer is very efficient and minimizes environmental drug contamination since no aerosol is produced, unless the patient is inspiring through the device. Our aim is to develop an appropriate delivery system suitable for children that does not disrupt the liposomes due to the shear forces in nebulization. METHODS This is an in vitro experimental study in vitro. Six ml of 4 mg/ml liposomal Amphotericin B solution (AmBisome®; Astellas Pharma Inc., Markham, Ontario, CA) was nebulized with the breath-actuated nebulizer (AeroEclipse®; Trudell Medical International, Canada) and captured by the glass liquid impinger. Sodium dodecyl sulfate was used as detergent to disrupt the liposomes in control samples. Gel filtration, electron microscopy, and high performance liquid chromatography (HPLC) were used to compare the size and shape of the liposomes, and amount of the drug before and after nebulization. The aerosol particle size was obtained by the laser diffraction. RESULTS After nebulization, 97.5% of amphotericin B was captured by the liquid impinger and detected by HPLC. Gel filtration and electron microscopy demonstrated that the drug remained in its liposomal configuration after nebulization. The mass median diameter (MMD) was 3.7 μm and 66% of aerosol particles were less than 5 μm in diameter. CONCLUSIONS We demonstrated that liposomal Amphotericin B can be nebulized successfully without disrupting the liposomes and minimize drug loss by using the breath-actuated nebulizer.
Collapse
Affiliation(s)
- Harutai Kamalaporn
- Division of Pulmonology, Department of Pediatrics, Ramathibodi Hospital, Mahidol University, Bangkok, Thailand
| | | | | | | | | | | | | |
Collapse
|
19
|
Lavorini F, Fontana GA, Usmani OS. New inhaler devices - the good, the bad and the ugly. Respiration 2014; 88:3-15. [PMID: 24902629 DOI: 10.1159/000363390] [Citation(s) in RCA: 89] [Impact Index Per Article: 8.9] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Abstract
Drug delivery to the lungs is an effective way of targeting inhaled therapeutic aerosols and treating obstructive airway diseases, such as asthma and chronic obstructive pulmonary disease (COPD). In the past 10 years, several new drugs for the management of asthma and COPD have been marketed and more are under development. These new therapeutic respiratory drugs have been furthered by innovations in all categories of pulmonary drug delivery systems to ensure optimal aerosolisation performance, consistency in efficacy and satisfactory patient adherence. In this review, we discuss the technological advances and innovations in recent inhaler devices and the evolving roles of pressurised metered-dose inhalers, dry powder inhalers and nebulisers, as well as their impact on patient adherence to treatment.
Collapse
Affiliation(s)
- Federico Lavorini
- Department of Experimental and Clinical Medicine, Careggi University Hospital, Florence, Italy
| | | | | |
Collapse
|
20
|
Ehsan Z, Wetzel JD, Clancy JP. Nebulized liposomal amikacin for the treatment of Pseudomonas aeruginosa infection in cystic fibrosis patients. Expert Opin Investig Drugs 2014; 23:743-9. [PMID: 24597573 DOI: 10.1517/13543784.2014.895322] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
INTRODUCTION Chronic lung infection with Pseudomonas aeruginosa (PsA) is associated with more-rapid pulmonary decline and acute pulmonary exacerbations in patients with cystic fibrosis (CF). The treatment and eradication of this organism from CF airways is particularly difficult, making it the focus of many therapeutic endeavors. Inhaled antibiotics used for PsA treatment help to suppress growth of the organism, maintain lung function and reduce the frequency of pulmonary exacerbations. AREAS COVERED Herein, the authors discuss the currently available inhaled antibiotics for management of lung infections in CF patients. They also describe the recent results from clinical trials of agents under development, with a focus on liposomal amikacin for inhalation (LAI, Arikace™). The article also provides a summary of the results from relevant articles published in the English. EXPERT OPINION LAI is a unique formulation of amikacin that enhances drug delivery and retention in CF airways via incorporation into neutral liposomes. Results of a recent Phase II trial suggest that LAI, with the capacity for once-daily dosing and prolonged off-drug periods, may be an attractive choice of inhaled antibiotic to manage PsA lung infections in CF patients. Further data from Phase III studies assessing the efficacy and safety of LAI should better elucidate its potential.
Collapse
Affiliation(s)
- Zarmina Ehsan
- University of Cincinnati, Cincinnati Children's Hospital Medical Center, Division of Pulmonary Medicine, Department of Pediatrics , MLC 2021 3333 Burnet Avenue, Cincinnati, OH 45220 , USA
| | | | | |
Collapse
|
21
|
Zarogoulidis P, Kioumis I, Porpodis K, Spyratos D, Tsakiridis K, Huang H, Li Q, Turner JF, Browning R, Hohenforst-Schmidt W, Zarogoulidis K. Clinical experimentation with aerosol antibiotics: current and future methods of administration. DRUG DESIGN DEVELOPMENT AND THERAPY 2013; 7:1115-34. [PMID: 24115836 PMCID: PMC3793595 DOI: 10.2147/dddt.s51303] [Citation(s) in RCA: 47] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
Currently almost all antibiotics are administered by the intravenous route. Since several systems and situations require more efficient methods of administration, investigation and experimentation in drug design has produced local treatment modalities. Administration of antibiotics in aerosol form is one of the treatment methods of increasing interest. As the field of drug nanotechnology grows, new molecules have been produced and combined with aerosol production systems. In the current review, we discuss the efficiency of aerosol antibiotic studies along with aerosol production systems. The different parts of the aerosol antibiotic methodology are presented. Additionally, information regarding the drug molecules used is presented and future applications of this method are discussed.
Collapse
Affiliation(s)
- Paul Zarogoulidis
- Pulmonary Department, G Papanikolaou General Hospital, Aristotle University of Thessaloniki, Thessaloniki, Greece ; Department of Interventional Pneumology, Ruhrlandklinik, West German Lung Center, University Hospital, University Duisburg-Essen, Essen, Germany
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
22
|
The challenge of delivering therapeutic aerosols to asthma patients. ISRN ALLERGY 2013; 2013:102418. [PMID: 23984095 PMCID: PMC3747606 DOI: 10.1155/2013/102418] [Citation(s) in RCA: 57] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/16/2013] [Accepted: 06/23/2013] [Indexed: 11/17/2022]
Abstract
The number of people with asthma continues to grow around the world, and asthma remains a poorly controlled disease despite the availability of management guidelines and highly effective medication. Patient noncompliance with therapy is a major reason for poor asthma control. Patients fail to comply with their asthma regimen for a wide variety of reasons, but incorrect use of inhaler devices is amongst the most common. The pressurised metered-dose inhaler (pMDI) is still the most frequently used device worldwide, but many patients fail to use it correctly, even after repeated tuition. Breath-actuated inhalers are easier to use than pMDIs. The rationale behind inhaler choice should be evidence based rather than empirical. When choosing an inhaler device, it is essential that it is easy to use correctly, dosing is consistent, adequate drug is deposited in both central and peripheral airways, and that drug deposition is independent of airflow. Regular checking of inhalation technique is crucial, as correct inhalation is one of the cornerstones of successful asthma management.
Collapse
|
23
|
Zarogoulidis P, Kioumis I, Ritzoulis C, Petridis D, Darwiche K, Porpodis K, Spyratos D, Parrish S, Browning R, Li Q, Turner JF, Freitag L, Zarogoulidis K. New insights in the production of aerosol antibiotics. Evaluation of the optimal aerosol production system for ampicillin-sulbactam, meropenem, ceftazidime, cefepime and piperacillin-tazobactam. Int J Pharm 2013; 455:182-8. [PMID: 23891745 DOI: 10.1016/j.ijpharm.2013.07.040] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2013] [Revised: 07/15/2013] [Accepted: 07/17/2013] [Indexed: 02/04/2023]
Abstract
BACKGROUND Several aerosol antibiotics are on the market and several others are currently being evaluated. Aim of the study was to evaluate the aerosol droplet size of five different antibiotics for future evaluation as an aerosol administration. MATERIALS AND METHODS The nebulizers Sunmist(®), Maxineb(®) and Invacare(®) were used in combination with four different "small <6 ml" residual cups and two "large <10 ml" with different loadings 2-4-6-8 ml (8 ml only for large residual cups) with five different antibiotic drugs (ampicilln-sulbactam, meropenem, ceftazidime, cefepime and piperacillin-tazobactam). The Mastersizer 2000 (Malvern) was used to evaluate the produced droplet size from each combination RESULTS Significant effect on the droplet size produced the different antibiotic (F=96.657, p<0.001) and the residual cup design (F=68.535, p<0.001) but not the different loading amount (p=0.127) and the nebulizer (p=0.715). Interactions effects were found significant only between antibiotic and residual cup (F=16.736, p<0.001). No second order interactions were found statistically significant. CONCLUSION Our results firstly indicate us indirectly that the chemical formulation of the drug is the main factor affecting the produced droplet size and secondly but closely the residual cup design.
Collapse
Affiliation(s)
- Paul Zarogoulidis
- Pulmonary Department-Oncology Unit, G. Papanikolaou General Hospital, Aristotle Univesrity of Thessaloniki, Thessaloniki, Greece.
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
24
|
Establishing the optimal nebulization system for paclitaxel, docetaxel, cisplatin, carboplatin and gemcitabine: back to drawing the residual cup. Int J Pharm 2013; 453:480-7. [PMID: 23769993 DOI: 10.1016/j.ijpharm.2013.06.011] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2013] [Revised: 06/06/2013] [Accepted: 06/10/2013] [Indexed: 11/21/2022]
Abstract
BACKGROUND Chemotherapy drugs have still the major disadvantage of non-specific cytotoxic effects. Although, new drugs targeting the genome of the tumor are already in the market, doublet chemotherapy regimens still remain the cornerstone of lung cancer treatment. Novel modalities of administration are under investigation such as; aerosol, intratumoral and intravascular. MATERIALS AND METHODS In the present study five chemotherapy drugs; paclitaxel, docetaxel, gemcitabine, carboplatin and cisplatin were nebulized with three different jet nebulizers (Maxineb(®), Sunmist(®), Invacare(®)) and six different residual cups at different concentrations. The purpose of the study was to identify the "ideal" combination of nebulizer-residual cup design-drug-drug loading for a future concept of aerosol chemotherapy in lung cancer patients. The Mastersizer(®) 2000 was used to evaluate the aerosol droplet mass median aerodynamic diameter. RESULTS The drug, nebulizer and residual cup design greatly influences the producing droplet size (p<0.005, in each case). However; the design of the residual cup is the most important factor affecting the produced droplet size (F=834.6, p<0.001). The drug loading plays a vital role in the production of the desired droplet size (F=10.42, p<0.001). The smallest droplet size was produced at 8 ml loading (1.26 μm), while it remained the same at 2, 4 and 6 mls of drug loading. CONCLUSION The ideal nebulizer would be Maxineb(®), with a large residual cup (10 ml maximum loading capacity) and 8 mls loading and the drug with efficient pulmonary deposition would be docetaxel.
Collapse
|
25
|
Tiemersma S, Minocchieri S, van Lingen RA, Nelle M, Devadason SG. Vibrating membrane devices deliver aerosols more efficient than standard devices: a study in a neonatal upper airway model. J Aerosol Med Pulm Drug Deliv 2012; 26:280-6. [PMID: 23273244 DOI: 10.1089/jamp.2012.0993] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022] Open
Abstract
BACKGROUND Aerosol therapy in preterm infants is challenging, as a very small proportion of the drug deposits in the lungs. AIM Our aim was to compare efficiency of standard devices with newer, more efficient aerosol delivery devices. METHODS Using salbutamol as a drug marker, we studied two prototypes of the investigational eFlow(®) nebulizer for babies (PARI Pharma GmbH), a jet nebulizer (Intersurgical(®) Cirrus(®)), and a pressurized metered dose inhaler (pMDI; GSK) with a detergent-coated holding chamber (AeroChamber(®) MV) in the premature infant nose throat-model (PrINT-model) of a 32-week preterm infant (1,750 g). A filter or an impactor was placed below the infant model's "trachea" to capture the drug dose or particle size, respectively, that would have been deposited in the lung. RESULTS Lung dose (percentage of nominal dose) was 1.5%, 6.8%, and 18.0-20.6% for the jet nebulizer, pMDI-holding chamber, and investigational eFlow nebulizers, respectively (p<0.001). Jet nebulizer residue was 69.4% and 10.7-13.9% for the investigational eFlow nebulizers (p<0.001). Adding an elbow extension between the eFlow and the model significantly lowered lung dose (p<0.001). A breathing pattern with lower tidal volume decreased deposition in the PrINT-model and device residue (p<0.05), but did not decrease lung dose. CONCLUSIONS In a model for infant aerosol inhalation, we confirmed low lung dose using jet nebulizers and pMDI-holding chambers, whereas newer, more specialized vibrating membrane devices, designed specifically for use in preterm infants, deliver up to 20 times more drug to the infant's lung.
Collapse
Affiliation(s)
- Sybrich Tiemersma
- 1 Princess Amalia Department of Paediatrics, Division of Neonatology, Isala Clinics , 8000 GK Zwolle, The Netherlands
| | | | | | | | | |
Collapse
|
26
|
Conway J. Lung imaging - two dimensional gamma scintigraphy, SPECT, CT and PET. Adv Drug Deliv Rev 2012; 64:357-68. [PMID: 22310158 DOI: 10.1016/j.addr.2012.01.013] [Citation(s) in RCA: 42] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2011] [Revised: 01/18/2012] [Accepted: 01/24/2012] [Indexed: 12/17/2022]
Abstract
This review will cover the principles of imaging the deposition of inhaled drugs and some of the state-of-the art imaging techniques being used today. Aerosol deposition can be imaged and quantified by the addition of a radiolabel to the aerosol formulation. The subsequent imaging of the inhaled deposition pattern can be acquired by different imaging techniques. Specifically, this review will focus on the use of two-dimensional planar, gamma scintigraphy, SPECT, CT and PET. This review will look at how these imaging techniques are used to investigate the mechanisms of drug delivery in the lung and how the lung anatomy and physiology have the potential to alter therapeutic outcomes.
Collapse
Affiliation(s)
- Joy Conway
- Faculty of Health Sciences, University of Southampton, Southampton General Hospital, UK.
| |
Collapse
|