Aubriot AS, Maerckx G, Leal T, Gohy S, Reychler G. Comparison of amikacin lung delivery between AKITA® and eFlow rapid® nebulizers in healthy controls and patients with CF: A randomized cross-over trial. Respir Med Res 2023; 84:101038. [PMID: 37734235 DOI: 10.1016/j.resmer.2023.101038] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2023] [Revised: 05/10/2023] [Accepted: 06/25/2023] [Indexed: 09/23/2023]
Abstract
INTRODUCTION Nebulization plays a key role in the treatment of cystic fibrosis. The Favorite function couple to jet nebulizers (AKITA®) emerged recently. The aim of this study was to assess the efficiency of the lung delivery by the AKITA® by comparing the urinary concentration of amikacin after nebulization with the AKITA® and the eFlow rapid®, in healthy subjects and patients with CF (PwCF). METHOD The two samples (healthy subjects and PwCF) were randomized (cross-over 1:1) for two nebulizations (500 mg of amikacin diluted in 4 mL of normal saline solution), with the AKITA® and with the eFlow rapid®. The primary endpoint was the amount of urinary excretion of amikacin over 24 h. The constant of elimination (Ke) was calculated based on the maximal cumulative urinary amikacin excretion plotted over time. RESULTS The total amount of urinary amikacin excretion was greater when AKITA® was used in PwCF (11.7 mg (8.2-14.1) vs 6.1 mg (3.7-13.3); p = 0.02) but not different in healthy subjects (14.5 mg (11.7-18.5) vs 12.4 mg (8.0-17.1); p = 0.12). The duration of the nebulization was always shorter with eFlow rapid® than with AKITA® (PwCF: 6.5 ± 0.6 min vs 9.2 ± 1.8 min; p = 0.001 - Healthy: 4.7 ± 1.3 min vs 9.7 ± 1.6 min; p = 0.03). The constant of elimination was similar between the two modalities in CF subjects (0.153 (0.071-0.205) vs 0.149 (0.041-0.182); p = 0.26) and in healthy subjects (0.166 (0.130-0.218) vs 0.167 (0.119-0.210), p = 0.25). CONCLUSION the Favorite inhalation is better to deliver a specific amount of drug than a mesh nebulizer (eFlow rapid®) in PwCF but not in healthy subjects.
Collapse
Affiliation(s)
- Anne-Sophie Aubriot
- Institut de Recherche Expérimentale et Clinique (IREC), Pôle de Pneumologie, ORL & Dermatologie, Université Catholique de Louvain, Avenue Hippocrate 10, 1200 Brussels, Belgium; Cliniques universitaires Saint-Luc, Cystic Fibrosis reference centre, Université catholique de Louvain, Avenue Hippocrate 10, B-1200 Brussels, Belgium; Secteur de kinésithérapie et ergothérapie, Cliniques universitaires Saint-Luc, Avenue Hippocrate 10, 1200 Brussels, Belgium
| | - Guillaume Maerckx
- Institut de Recherche Expérimentale et Clinique (IREC), Pôle de Pneumologie, ORL & Dermatologie, Université Catholique de Louvain, Avenue Hippocrate 10, 1200 Brussels, Belgium; Secteur de kinésithérapie et ergothérapie, Cliniques universitaires Saint-Luc, Avenue Hippocrate 10, 1200 Brussels, Belgium
| | - Teresinha Leal
- IREC, Louvain centre for Toxicology and Applied Pharmacology, Université Catholique de Louvain, Avenue Hippocrate 10, B-1200 Brussels, Belgium
| | - Sophie Gohy
- Institut de Recherche Expérimentale et Clinique (IREC), Pôle de Pneumologie, ORL & Dermatologie, Université Catholique de Louvain, Avenue Hippocrate 10, 1200 Brussels, Belgium; Cliniques universitaires Saint-Luc, Cystic Fibrosis reference centre, Université catholique de Louvain, Avenue Hippocrate 10, B-1200 Brussels, Belgium; Service de Pneumologie, Cliniques universitaires Saint-Luc, Avenue Hippocrate 10, 1200 Brussels, Belgium
| | - Gregory Reychler
- Institut de Recherche Expérimentale et Clinique (IREC), Pôle de Pneumologie, ORL & Dermatologie, Université Catholique de Louvain, Avenue Hippocrate 10, 1200 Brussels, Belgium; Secteur de kinésithérapie et ergothérapie, Cliniques universitaires Saint-Luc, Avenue Hippocrate 10, 1200 Brussels, Belgium; Service de Pneumologie, Cliniques universitaires Saint-Luc, Avenue Hippocrate 10, 1200 Brussels, Belgium.
| |
Collapse
|
2
|
Jung YJ, Kim EJ, Choi YH. Aerosolized antibiotics in the treatment of hospital-acquired pneumonia/ventilator-associated pneumonia. Korean J Intern Med 2022; 37:1-12. [PMID: 34666432 PMCID: PMC8747925 DOI: 10.3904/kjim.2021.277] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/16/2021] [Accepted: 07/22/2021] [Indexed: 01/02/2023] Open
Abstract
Aerosolized antibiotics are being increasingly used to treat respiratory infections, especially those caused by drug-resistant pathogens. Their use in the treatment of hospital-acquired pneumonia and ventilator-associated pneumonia in critically ill patients is especially significant. They are also used as an efficient alternative to overcome the issues caused by systemic administration of antibiotics, including the occurrence of drug-resistant strains, drug toxicity, and insufficient drug concentration at the target site. However, the rationale for the use of aerosolized antibiotics is limited owing to their insufficient efficacy and the potential for underestimated risks of developing side effects. Despite the lack of availability of high-quality evidence, the use of aerosolized antibiotics is considered as an attractive alternative treatment approach, especially in patients with multidrug-resistant pathogens. In this review, we have discussed the effectiveness and side effects of aerosolized antibiotics as well as the latest advancements in this field and usage in the Republic of Korea.
Collapse
Affiliation(s)
- Yun Jung Jung
- Department of Pulmonary and Critical Care Medicine, Ajou University School of Medicine, Suwon, Korea
| | - Eun Jin Kim
- Department of Infectious Diseases, Ajou University School of Medicine, Suwon,
Korea
| | - Young Hwa Choi
- Department of Infectious Diseases, Ajou University School of Medicine, Suwon,
Korea
| |
Collapse
|
3
|
Wiegandt FC, Biegger D, Fast JF, Matusiak G, Mazela J, Ortmaier T, Doll T, Dietzel A, Bohnhorst B, Pohlmann G. Detection of Breathing Movements of Preterm Neonates by Recording Their Abdominal Movements with a Time-of-Flight Camera. Pharmaceutics 2021; 13:pharmaceutics13050721. [PMID: 34068978 PMCID: PMC8156597 DOI: 10.3390/pharmaceutics13050721] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2021] [Revised: 05/10/2021] [Accepted: 05/11/2021] [Indexed: 12/20/2022] Open
Abstract
In order to deliver an aerosolized drug in a breath-triggered manner, the initiation of the patient’s inspiration needs to be detected. The best-known systems monitoring breathing patterns are based on flow sensors. However, due to their large dead space volume, flow sensors are not advisable for monitoring the breathing of (preterm) neonates. Newly-developed respiratory sensors, especially when contact-based (invasive), can be tested on (preterm) neonates only with great effort due to clinical and ethical hurdles. Therefore, a physiological model is highly desirable to validate these sensors. For developing such a system, abdominal movement data of (preterm) neonates are required. We recorded time sequences of five preterm neonates’ abdominal movements with a time-of-flight camera and successfully extracted various breathing patterns and respiratory parameters. Several characteristic breathing patterns, such as forced breathing, sighing, apnea and crying, were identified from the movement data. Respiratory parameters, such as duration of inspiration and expiration, as well as respiratory rate and breathing movement over time, were also extracted. This work demonstrated that respiratory parameters of preterm neonates can be determined without contact. Therefore, such a system can be used for breathing detection to provide a trigger signal for breath-triggered drug release systems. Furthermore, based on the recorded data, a physiological abdominal movement model of preterm neonates can now be developed.
Collapse
Affiliation(s)
- Felix C. Wiegandt
- Division of Translational Biomedical Engineering, Fraunhofer Institute for Toxicology and Experimental Medicine ITEM, 30625 Hannover, Germany; (D.B.); (T.D.)
- Correspondence: (F.C.W.); (G.P.); Tel.: +49-511-5350-287 (F.C.W.); +49-511-5350-116 (G.P.)
| | - David Biegger
- Division of Translational Biomedical Engineering, Fraunhofer Institute for Toxicology and Experimental Medicine ITEM, 30625 Hannover, Germany; (D.B.); (T.D.)
| | - Jacob F. Fast
- Institute of Mechatronic Systems, Leibniz Universität Hannover, 30823 Garbsen, Germany; (J.F.F.); (T.O.)
- Department of Phoniatrics and Pediatric Audiology, Hannover Medical School, 30625 Hannover, Germany
| | - Grzegorz Matusiak
- Division of Infectious Diseases, Department of Neonatology, Poznan University of Medical Sciences, 61-701 Poznan, Poland; (G.M.); (J.M.)
| | - Jan Mazela
- Division of Infectious Diseases, Department of Neonatology, Poznan University of Medical Sciences, 61-701 Poznan, Poland; (G.M.); (J.M.)
| | - Tobias Ortmaier
- Institute of Mechatronic Systems, Leibniz Universität Hannover, 30823 Garbsen, Germany; (J.F.F.); (T.O.)
| | - Theodor Doll
- Division of Translational Biomedical Engineering, Fraunhofer Institute for Toxicology and Experimental Medicine ITEM, 30625 Hannover, Germany; (D.B.); (T.D.)
- Department of Otorhinolaryngology, Hannover Medical School, 30625 Hannover, Germany
| | - Andreas Dietzel
- Institute of Microtechnology, Technische Universität Braunschweig, 38124 Braunschweig, Germany;
| | - Bettina Bohnhorst
- Department of Pediatric Pulmonology, Allergology and Neonatology, Hannover Medical School, 30625 Hannover, Germany;
| | - Gerhard Pohlmann
- Division of Translational Biomedical Engineering, Fraunhofer Institute for Toxicology and Experimental Medicine ITEM, 30625 Hannover, Germany; (D.B.); (T.D.)
- Correspondence: (F.C.W.); (G.P.); Tel.: +49-511-5350-287 (F.C.W.); +49-511-5350-116 (G.P.)
| |
Collapse
|
4
|
Wiegandt FC, Froriep UP, Müller F, Doll T, Dietzel A, Pohlmann G. Breath-Triggered Drug Release System for Preterm Neonates. Pharmaceutics 2021; 13:pharmaceutics13050657. [PMID: 34064425 PMCID: PMC8147847 DOI: 10.3390/pharmaceutics13050657] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2021] [Revised: 04/19/2021] [Accepted: 04/20/2021] [Indexed: 11/24/2022] Open
Abstract
A major disadvantage of inhalation therapy with continuous drug delivery is the loss of medication during expiration. Developing a breath-triggered drug release system can highly decrease this loss. However, there is currently no breath-triggered drug release directly inside the patient interface (nasal prong) for preterm neonates available due to their high breathing frequency, short inspiration time and low tidal volume. Therefore, a nasal prong with an integrated valve releasing aerosol directly inside the patient interface increasing inhaled aerosol efficiency is desirable. We integrated a miniaturized aerosol valve into a nasal prong, controlled by a double-stroke cylinder. Breathing was simulated using a test lung for preterm neonates on CPAP respiratory support. The inhalation flow served as a trigger signal for the valve, releasing humidified surfactant. Particle detection was performed gravimetrically (filter) and optically (light extinction). The integrated miniaturized aerosol valve enabled breath-triggered drug release inside the patient interface with an aerosol valve response time of <25 ms. By breath-triggered release of the pharmaceutical aerosol as a bolus during inhalation, the inhaled aerosol efficiency was increased by a factor of >4 compared to non-triggered release. This novel nasal prong with integrated valve allows breath-triggered drug release directly inside the nasal prong with short response time.
Collapse
Affiliation(s)
- Felix C. Wiegandt
- Division of Translational Biomedical Engineering, Fraunhofer Institute for Toxicology and Experimental Medicine ITEM, 30625 Hannover, Germany; (U.P.F.); (F.M.); (T.D.)
- Correspondence: (F.C.W.); (G.P.); Tel.: +49-511-5350-287 (F.C.W.); +49-511-5350-116 (G.P.)
| | - Ulrich P. Froriep
- Division of Translational Biomedical Engineering, Fraunhofer Institute for Toxicology and Experimental Medicine ITEM, 30625 Hannover, Germany; (U.P.F.); (F.M.); (T.D.)
| | - Fabian Müller
- Division of Translational Biomedical Engineering, Fraunhofer Institute for Toxicology and Experimental Medicine ITEM, 30625 Hannover, Germany; (U.P.F.); (F.M.); (T.D.)
| | - Theodor Doll
- Division of Translational Biomedical Engineering, Fraunhofer Institute for Toxicology and Experimental Medicine ITEM, 30625 Hannover, Germany; (U.P.F.); (F.M.); (T.D.)
- Department of Otorhinolaryngology, Hannover Medical School, 30625 Hannover, Germany
| | - Andreas Dietzel
- Institute of Microtechnology, Technische Universität Braunschweig, 38124 Braunschweig, Germany;
| | - Gerhard Pohlmann
- Division of Translational Biomedical Engineering, Fraunhofer Institute for Toxicology and Experimental Medicine ITEM, 30625 Hannover, Germany; (U.P.F.); (F.M.); (T.D.)
- Correspondence: (F.C.W.); (G.P.); Tel.: +49-511-5350-287 (F.C.W.); +49-511-5350-116 (G.P.)
| |
Collapse
|
5
|
Lyu S, Li J, Yang L, Du X, Liu X, Chuan L, Jing G, Wang Z, Shu W, Ye C, Dong Q, Duan J, Fink JB, Gao Z, Liang Z. The utilization of aerosol therapy in mechanical ventilation patients: a prospective multicenter observational cohort study and a review of the current evidence. ANNALS OF TRANSLATIONAL MEDICINE 2020; 8:1071. [PMID: 33145290 PMCID: PMC7575997 DOI: 10.21037/atm-20-1313] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Background Aerosol delivery via mechanical ventilation has been reported to vary significantly among different intensive care units (ICU). The optimal technique for using each aerosol generator may need to be updated with the available evidence. Methods A 2-week prospective multicenter observational cohort study was implemented to record aerosol delivery for mechanically ventilated adult patients in Chinese ICUs. Our data included the type of aerosol device and its placement, ventilator type, humidification, and aerosolized medication administered. A guide for the optimal technique for aerosol delivery during mechanical ventilation was summarized after a thorough literature review. Results A total of 160 patients (105 males) from 28 ICUs were enrolled, of whom 125 (78.1%) received aerosol therapy via invasive ventilation. Among these 125 patients, 53 received ventilator-integrated jet nebulizer, with 64% (34/53) of them placed the nebulizer close to Y piece in the inspiratory limb. Further, 56 patients used continuous nebulizers, with 84% (47/56) of them placed the nebulizer close to the Y piece in the inspiratory limb. Of the 35 patients who received aerosol therapy via noninvasive ventilation, 30 received single limb ventilators and continuous nebulizers, with 70% (21/30) of them placed between the mask and exhalation port. Only 36% (58/160) of the patients received aerosol treatments consistent with optimal practice. Conclusions Aerosol delivery via mechanical ventilation varied between ICUs, and only 36% of the patients received aerosol treatments consistent with optimal practice. ICU clinicians should be educated on the best practices for aerosol therapy, and quality improvement projects aim to improve the quality and outcome of patients with the optimal technique for aerosol delivery during mechanical ventilation are warranted.
Collapse
Affiliation(s)
- Shan Lyu
- Department of Critical Care Medicine, Peking University People's Hospital, Beijing, China
| | - Jie Li
- Department of Cardiopulmonary Sciences, Division of Respiratory Care, Rush University Medical Center, Chicago, IL, USA
| | - Limin Yang
- Department of Respiratory Care, Zhejiang University School of Medical Sir Run Run Shaw Hospital, Hangzhou, China
| | - Xiaoliang Du
- Department of Neurosurgical, Tongji Medical College of Huazhong University of Science and Technology Tongji Hospital, Wuhan, China
| | - Xiaoyi Liu
- Department of Critical Care Medicine, Dazhou Central Hospital, Dazhou, China
| | - Libo Chuan
- Intensive Care Unit, the First People's Hospital of Yunnan Province, Kunming, China
| | - Guoqiang Jing
- Department of Respiratory and Critical Care Medicine, Binzhou Medical University Hospital, Binzhou, China
| | - Zhenyan Wang
- Department of Critical Care Medicine, Peking University International Hospital, Beijing, China
| | - Weiwei Shu
- Department of Critical Care Medicine, Yongchuan Hospital of Chongqing Medical University, Chongqing, China
| | - Chunjuan Ye
- Department of Surgical Intensive Care Unit, the First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, China
| | - Qionglan Dong
- Department of Critical Care Medicine, the Third People's Hospital of Mianyang, Mianyang, China
| | - Jun Duan
- Department of Respiratory and Critical Care Medicine, the First Affiliated Hospital of Chongqing Medical University, Chongqing, China
| | - James B Fink
- Department of Cardiopulmonary Sciences, Division of Respiratory Care, Rush University Medical Center, Chicago, IL, USA.,Aerogen Pharma Corp, San Mateo, CA, USA
| | - Zhancheng Gao
- Department of Respiratory and Critical Care Medicine, Peking University People's Hospital, Beijing, China
| | - Zongan Liang
- Department of Respiratory and Critical Care Medicine, West China Medical Center, Sichuan University, Chengdu, China
| |
Collapse
|
6
|
Li J, Fink JB, MacLoughlin R, Dhand R. A narrative review on trans-nasal pulmonary aerosol delivery. CRITICAL CARE : THE OFFICIAL JOURNAL OF THE CRITICAL CARE FORUM 2020; 24:506. [PMID: 32807226 PMCID: PMC7430014 DOI: 10.1186/s13054-020-03206-9] [Citation(s) in RCA: 30] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/01/2020] [Accepted: 07/27/2020] [Indexed: 01/21/2023]
Abstract
The use of trans-nasal pulmonary aerosol delivery via high-flow nasal cannula (HFNC) has expanded in recent years. However, various factors influencing aerosol delivery in this setting have not been precisely defined, and no consensus has emerged regarding the optimal techniques for aerosol delivery with HFNC. Based on a comprehensive literature search, we reviewed studies that assessed trans-nasal pulmonary aerosol delivery with HFNC by in vitro experiments, and in vivo, by radiolabeled, pharmacokinetic and pharmacodynamic studies. In these investigations, the type of nebulizer employed and its placement, carrier gas, the relationship between gas flow and patient’s inspiratory flow, aerosol delivery strategies (intermittent unit dose vs continuous administration by infusion pump), and open vs closed mouth breathing influenced aerosol delivery. The objective of this review was to provide rational recommendations for optimizing aerosol delivery with HFNC in various clinical settings.
Collapse
Affiliation(s)
- Jie Li
- Division of Respiratory Care, Department of Cardiopulmonary Sciences, Rush University Medical Center, 1620 W Harrison St, Tower LL1202, Chicago, IL, 60612, USA.
| | - James B Fink
- Division of Respiratory Care, Department of Cardiopulmonary Sciences, Rush University Medical Center, 1620 W Harrison St, Tower LL1202, Chicago, IL, 60612, USA.,Aerogen Pharma Corp, San Mateo, CA, USA
| | | | - Rajiv Dhand
- Department of Medicine, University of Tennessee Graduate School of Medicine, Knoxville, TN, USA
| |
Collapse
|
7
|
Li J, Wu W, Fink JB. In vitro comparison between inspiration synchronized and continuous vibrating mesh nebulizer during trans-nasal aerosol delivery. Intensive Care Med Exp 2020; 8:6. [PMID: 32006290 PMCID: PMC6994578 DOI: 10.1186/s40635-020-0293-7] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2019] [Accepted: 01/14/2020] [Indexed: 11/22/2022] Open
Abstract
BACKGROUND Compared to continuous vibrating mesh nebulizer (VMN), inspiration synchronized VMN has shown increased inhaled dose during noninvasive ventilation; however, its use during aerosol delivery via high-flow nasal cannula (HFNC) is still unknown. METHODS An adult manikin was connected to a dual-chamber model lung, which was driven by a critical care ventilator to simulate spontaneous breathing. A HFNC system was utilized with temperature at 37 ° C while gas flow at 5, 10, 20, 40, and 60 L/min. Inspiration synchronized and continuous aerosol generation were compared at different positions (at the inlet of humidifier vs close to patient). One milliliter of albuterol (2.5 mg/mL) was used in each run (n = 3). Collection filter was placed at the trachea and was removed after each run. Drug was eluted from the filter and assayed with UV spectrophotometry (276 nm). RESULTS When nebulizer was placed close to patient, inhaled dose was higher with inspiration synchronized than continuous aerosol generation at all gas flows (p = 0.05) except at 5 L/min. When placed at the inlet of humidifier, compared to continuous, inspiration synchronized aerosol generated higher inhaled dose with gas flow set below 50% of patient inspiratory flow [23.9 (20.6, 28.3)% vs 18.1 (16.7, 19.6)%, p < 0.001], but lower inhaled dose with gas flow set above 50% of patient inspiratory flow [3.5 (2.2, 9.3)% vs 9.9 (8.2, 16.4)%, p = 0.001]. Regardless of breathing pattern, continuous aerosol delivered greater inhaled dose with nebulizer placed at humidifier than close to patient at all gas flows except at 5 L/min. CONCLUSION When the HFNC gas flow was set higher than 50% of patient inspiratory flow, no significant advantage was found in inspiration synchronized over continuous aerosol. However, inspiration synchronized aerosol generated 30% more inhaled dose than continuous with gas flow set below 50% of patient inspiratory flow, regardless of nebulizer placement. Continuous nebulizer needs to be placed at the inlet of humidifier.
Collapse
Affiliation(s)
- Jie Li
- Department of Cardiopulmonary Sciences, Division of Respiratory Care, Rush University Medical Center, 1620 W Harrison St, Tower LL1202, Chicago, IL, 60612, USA.
| | - Wei Wu
- Department of Critical Care Medicine, Shanghai Zhongshan Hospital, Fu Dan University, Shanghai, China
| | - James B Fink
- Department of Cardiopulmonary Sciences, Division of Respiratory Care, Rush University Medical Center, 1620 W Harrison St, Tower LL1202, Chicago, IL, 60612, USA
- Aerogen Pharma Corp, San Mateo, CA, USA
| |
Collapse
|
8
|
Reychler G, Michotte JB. Development challenges and opportunities in aerosol drug delivery systems in non-invasive ventilation in adults. Expert Opin Drug Deliv 2019; 16:153-162. [DOI: 10.1080/17425247.2019.1572111] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Affiliation(s)
- Gregory Reychler
- Institut de Recherche Expérimentale et Clinique (IREC), Pôle de Pneumologie, ORL & Dermatologie, Université Catholique de Louvain, Bruxelles, Belgium
- Service de Pneumologie, Cliniques universitaires Saint-Luc, Bruxelles, Belgium
| | - Jean-Bernard Michotte
- Institut de Recherche Expérimentale et Clinique (IREC), Pôle de Pneumologie, ORL & Dermatologie, Université Catholique de Louvain, Bruxelles, Belgium
- Filière Physiothérapie, School of Health Sciences (HESAV), HES-SO University of Applied Sciences and Arts Western Switzerland, Lausanne, Switzerland
| |
Collapse
|
9
|
Kadrichu N, Daniher D. Improvement of an In Vitro Model to Assess Delivered Dose and Particle Size for a Vibrating Mesh Nebulizer During Mechanical Ventilation. J Aerosol Med Pulm Drug Deliv 2018; 31:94-102. [DOI: 10.1089/jamp.2017.1372] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
10
|
Michotte JB, Staderini E, Aubriot AS, Jossen E, Dugernier J, Liistro G, Reychler G. Pulmonary Drug Delivery Following Continuous Vibrating Mesh Nebulization and Inspiratory Synchronized Vibrating Mesh Nebulization During Noninvasive Ventilation in Healthy Volunteers. J Aerosol Med Pulm Drug Deliv 2017; 31:33-41. [PMID: 28683216 DOI: 10.1089/jamp.2016.1339] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
BACKGROUND A breath-synchronized nebulization option that could potentially improve drug delivery during noninvasive positive pressure ventilation (NIPPV) is currently not available on single-limb circuit bilevel ventilators. The aim of this study was to compare urinary excretion of amikacin following aerosol delivery with a vibrating mesh nebulizer coupled to a single-limb circuit bilevel ventilator, using conventional continuous (Conti-Neb) and experimental inspiratory synchronized (Inspi-Neb) nebulization modes. MATERIALS AND METHODS A crossover clinical trial involving 6 noninvasive ventilated healthy volunteers (mean age of 32.3 ± 9.5 y) randomly assigned to both vibrating mesh nebulization modes was conducted: Inspi-Neb delivered aerosol during only the whole inspiratory phase, whereas Conti-Neb delivered aerosol continuously. All subjects inhaled amikacin solution (500 mg/4 mL) during NIPPV using a single-limb bilevel ventilator (inspiratory positive airway pressure: 12 cm H2O, and expiratory positive airway pressure: 5 cm H2O). Pulmonary drug delivery of amikacin following both nebulization modes was compared by urinary excretion of drug for 24 hours post-inhalation. RESULTS The total daily amount of amikacin excreted in the urine was significantly higher with Inspi-Neb (median: 44.72 mg; interquartile range [IQR]: 40.50-65.13) than with Conti-Neb (median: 40.07 mg; IQR: 31.00-43.73), (p = 0.02). The elimination rate constant of amikacin (indirect measure of the depth of drug penetration into the lungs) was significantly higher with Inspi-Neb (median: 0.137; IQR: 0.113-0.146) than with Conti-Neb (median: 0.116; IQR: 0.105-0.130), (p = 0.02). However, the mean pulmonary drug delivery rate, expressed as the ratio between total daily urinary amount of amikacin and nebulization time, was significantly higher with Conti-Neb (2.03 mg/min) than with Inspi-Neb (1.09 mg/min) (p < 0.01). CONCLUSIONS During NIPPV with a single-limb circuit bilevel ventilator, the use of inspiratory synchronized vibrating mesh nebulization may improve pulmonary drug delivery compared with conventional continuous vibrating mesh nebulization.
Collapse
Affiliation(s)
- Jean-Bernard Michotte
- 1 Western Switzerland University of Applied Sciences-Haute Ecole de Santé Vaud (HESAV), Filière Physiothérapie, 1011 Lausanne, Switzerland
| | - Enrico Staderini
- 2 Western Switzerland University of Applied Sciences-Haute Ecole d'Ingénierie et de Gestion du Canton de Vaud (HEIG-VD), 1401 Yverdon-les-Bains, Switzerland
| | - Anne-Sophie Aubriot
- 3 Cliniques Universitaires Saint-Luc, Centre de Référence pour la Mucoviscidose, 1200 Brussels, Belgium
| | - Emilie Jossen
- 4 Ligue pulmonaire neuchâteloise, 2034 Peseux, Switzerland
| | - Jonathan Dugernier
- 5 Cliniques Universitaires Saint-Luc, Service des soins intensifs, 1200 Brussels, Belgium
| | - Giuseppe Liistro
- 6 Cliniques Universitaires Saint-Luc, Service de Pneumologie; Université Catholique de Louvain, Institut de Recherche Expérimentale et Clinique (IREC), Pôle de Pneumologie, ORL & Dermatologie, 1200 Brussels, Belgium
| | - Gregory Reychler
- 6 Cliniques Universitaires Saint-Luc, Service de Pneumologie; Université Catholique de Louvain, Institut de Recherche Expérimentale et Clinique (IREC), Pôle de Pneumologie, ORL & Dermatologie, 1200 Brussels, Belgium
| |
Collapse
|
11
|
Saeed H, Mohsen M, Fink JB, Dailey P, Salah Eldin A, Abdelrahman MM, Elberry AA, Rabea H, Hussein RR, Abdelrahim ME. Fill volume, humidification and heat effects on aerosol delivery and fugitive emissions during noninvasive ventilation. J Drug Deliv Sci Technol 2017. [DOI: 10.1016/j.jddst.2017.04.026] [Citation(s) in RCA: 39] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
12
|
Abstract
In the later half of the 20th century, nebulized therapy was in decline, but in the 21st century the prospects for the expanded use of nebulized therapy within respiratory medicine look bright. The advent of mesh nebulizers, which combine the universal applicability of the nebulizer in the treatment of all respiratory patients with the convenience of portable inhaler use, is ideally timed to capitalize on the forecast of increased numbers of patients who will require nebulized therapy in the future. This special report will highlight some of the opportunities that the development of mesh nebulizers presents in the field of respiratory medicine.
Collapse
|