1
|
Sicard RM, Frank-Ito DO. Parameter characteristics in intranasal drug delivery: A key to targeting medications to the olfactory airspace. Clin Biomech (Bristol, Avon) 2024; 114:106231. [PMID: 38507865 DOI: 10.1016/j.clinbiomech.2024.106231] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/03/2023] [Revised: 02/23/2024] [Accepted: 03/12/2024] [Indexed: 03/22/2024]
Abstract
BACKGROUND The nose is a viable pathway for topical drug delivery to the olfactory cleft for treatment of obstructive smell loss and nose-to-brain drug delivery. This study investigates how variations in nasal vestibule morphology influence intranasal spray drug transport to the olfactory cleft and olfactory roof/bulb regions. METHODS The unilateral nasal vestibule morphology in three healthy subjects with healthy normal nasal anatomy was classified as Elongated (Subject DN001), Notched (Subject DN002), and Standard (Subject DN003). Computational fluid and particle dynamics modelling were used to simulate nasal airflow and drug particle transport to the olfactory cleft and olfactory roof/bulb regions in each subject-specific nasal cavity. To evaluate highest drug depositions in these regions, the particle transport simulations involved extensive parameter combination analyses: 6 inspiratory flow rates mimicking resting to sniffing (10-50 L/min); 5 spray release locations (Top, Bottom, Central, Lateral, and Medial); 5 head positions (Upright, Tilted Forward, Tilted Back, Supine, and Mygind); 3 particle velocities (1, 5, and 10 m/s); 350,000 μm-particles (1-100 μm) and 346,500 nanoparticles (10-990 nm). FINDINGS Particle size groups with highest depositions in olfactory cleft: DN001 left = 28.4% at 11-20 μm, right = 75.3% at 6-10 μm; DN002 left = 16.8% at 1-5 μm, right = 45.3% at 30-40 nm; DN003 left = 29.1% at 21-30 μm, right = 15.9% at 6-10 μm. Highest depositions in olfactory roof/bulb: DN001 left = 6.5% at 11-20 μm, right = 26.4% at 11-20 μm; DN002 left = 3.6% at 1-5 μm, right = 2.6% at 1-5 μm; DN003 left = 2.8% at 21-30 μm, right = 1.7% at 31-40 μm. INTERPRETATION DN001 (Elongated nasal vestibule) had the most deposition in the olfactory regions. Micron-particles size groups generally had better deposition in the olfactory regions.
Collapse
Affiliation(s)
- Ryan M Sicard
- Department of Head and Neck Surgery & Communication Sciences, Duke University Medical Center, Durham, NC, USA; Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - Dennis O Frank-Ito
- Department of Head and Neck Surgery & Communication Sciences, Duke University Medical Center, Durham, NC, USA; Computational Biology & Bioinformatics PhD Program, Duke University, Durham, NC, USA; Department of Mechanical Engineering and Materials Science, Duke University, Durham, NC, USA.
| |
Collapse
|
2
|
Hu Z, Cheng S, Sun S, Wang Y, Lou M, Ma R, Gong M, Yang F, Zheng G, Zhang Y, Dong J. Numerical and experimental evaluation of nasopharyngeal aerosol administration methods in children with adenoid hypertrophy. Int J Pharm 2024; 653:123906. [PMID: 38365069 DOI: 10.1016/j.ijpharm.2024.123906] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2023] [Revised: 02/03/2024] [Accepted: 02/13/2024] [Indexed: 02/18/2024]
Abstract
Administering aerosol drugs through the nasal pathway is a common early treatment for children with adenoid hypertrophy (AH). To enhance therapeutic efficacy, a deeper understanding of nasal drug delivery in the nasopharynx is essential. This study uses an integrated experimental, numerical modelling approach to investigate the delivery process of both the aerosol mask delivery system (MDS) and the bi-directional delivery system (BDS) in the pediatric nasal airway with AH. The combined effect of respiratory flow rates and particle size on delivery efficiency was systematically analyzed. The results showed that the nasopharyngeal peak deposition efficiency (DE) for BDS was approximately 2.25-3.73 times higher than that for MDS under low-flow, resting and high-flow respiratory conditions. Overall nasopharyngeal DEs for MDS were at a low level of below 16 %. For each respiratory flow rate, the BDS tended to achieve higher peak DEs (36.36 % vs 9.74 %, 37.80 % vs 14.01 %, 34.58 % vs 15.35 %) at smaller particle sizes (15 µm vs 17 µm, 10 µm vs 14 µm, 6 µm vs 9 µm). An optimal particle size exists for each respiratory flow rate, maximizing the drug delivery efficiency to the nasopharynx. The BDS is more effective in delivering drug aerosols to the nasal cavity and nasopharynx, which is crucial for early intervention in children with AH.
Collapse
Affiliation(s)
- Zhenzhen Hu
- Department of Otolaryngology Head and Neck Surgery, The Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi 710004, China; School of Engineering, RMIT University, Bundoora, VIC 3083, Australia; Institute for Sustainable Industries & Liveable Cities, Victoria University, PO Box 14428, Melbourne, VIC 8001, Australia
| | - Shaokoon Cheng
- School of Engineering, Faculty of Science and Engineering, Macquarie University, Sydney, NSW 2109, Australia
| | - Siping Sun
- Zhejiang Cuize Pharmtech Co. Ltd., Hangzhou, Zhejiang 310000, China
| | - Yusheng Wang
- Department of Otolaryngology Head and Neck Surgery, The Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi 710004, China
| | - Miao Lou
- Department of Otorhinolaryngology Head and Neck Surgery, Shaanxi Provincial People's Hospital, Xi'an, Shaanxi 710068, China
| | - Ruiping Ma
- Department of Otolaryngology Head and Neck Surgery, The Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi 710004, China
| | - Minjie Gong
- Department of Otolaryngology Head and Neck Surgery, The Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi 710004, China
| | - Feilun Yang
- Department of Otolaryngology Head and Neck Surgery, The Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi 710004, China
| | - Guoxi Zheng
- Department of Otolaryngology Head and Neck Surgery, The Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi 710004, China
| | - Ya Zhang
- Department of Otolaryngology Head and Neck Surgery, The Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi 710004, China.
| | - Jingliang Dong
- Department of Otolaryngology Head and Neck Surgery, The Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi 710004, China; Institute for Sustainable Industries & Liveable Cities, Victoria University, PO Box 14428, Melbourne, VIC 8001, Australia; First Year College, Victoria University, Footscray Park Campus, Footscray, VIC 3011, Australia.
| |
Collapse
|
3
|
Valerian Corda J, Shenoy BS, Ahmad KA, Lewis L, K P, Rao A, Zuber M. Comparison of microparticle transport and deposition in nasal cavity of three different age groups. Inhal Toxicol 2024; 36:44-56. [PMID: 38343121 DOI: 10.1080/08958378.2024.2312801] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2023] [Accepted: 01/23/2024] [Indexed: 02/22/2024]
Abstract
Objective: The nasal cavity effectively captures the particles present in inhaled air, thereby preventing harmful and toxic pollutants from reaching the lungs. This filtering ability of the nasal cavity can be effectively utilized for targeted nasal drug delivery applications. This study aims to understand the particle deposition patterns in three age groups: neonate, infant, and adult.Materials and methods: The CT scans are built using MIMICS 21.0, followed by CATIA V6 to generate a patient-specific airway model. Fluid flow is simulated using ANSYS FLUENT 2021 R2. Spherical monodisperse microparticles ranging from 2 to 60 µm and a density of 1100 kg/m3 are simulated at steady-state and sedentary inspiration conditions.Results: The highest nasal valve depositions for the neonate are 25% for 20 µm, for infants, 10% for 50 µm, 15% for adults, and 15% for 15 µm. At mid nasal region, deposition of 15% for 20 µm is observed for infant and 8% for neonate and adult nasal cavities at a particle size of 10 and 20 µm, respectively. The highest particle deposition at the olfactory region is about 2.7% for the adult nasal cavity for 20 µm, and it is <1% for neonate and infant nasal cavities.Discussion and conclusions: The study of preferred nasal depositions during natural sedentary breathing conditions is utilized to determine the size that allows medication particles to be targeted to specific nose regions.
Collapse
Affiliation(s)
- John Valerian Corda
- Department of Aeronautical & Automobile Engineering, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal-576104, Karnataka, India
| | - B Satish Shenoy
- Department of Aeronautical & Automobile Engineering, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal-576104, Karnataka, India
| | - Kamarul Arifin Ahmad
- Department of Aerospace Engineering, Universiti Putra Malaysia, Seri Kembangan, Malaysia
| | - Leslie Lewis
- Department of Paediatrics, Kasturba Medical College & Hospital, Manipal Academy of Higher Education, Manipal-576104, Karnataka, India
| | - Prakashini K
- Department of Radio Diagnosis, Kasturba Medical College & Hospital, Manipal Academy of Higher Education, Manipal-576104, Karnataka, India
| | - Anoop Rao
- Department of Pediatrics, Neonatology, Stanford University, Palo Alto, CA, USA
| | - Mohammad Zuber
- Department of Aeronautical & Automobile Engineering, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal-576104, Karnataka, India
| |
Collapse
|
4
|
Pang Y, Qu J, Zhang H, Cao Y, Ma X, Wang S, Wang J, Wu J, Zhang T. Nose-to-brain translocation and nervous system injury in response to indium tin oxide nanoparticles of long-term low-dose exposures. THE SCIENCE OF THE TOTAL ENVIRONMENT 2023; 905:167314. [PMID: 37742979 DOI: 10.1016/j.scitotenv.2023.167314] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/19/2023] [Revised: 09/20/2023] [Accepted: 09/21/2023] [Indexed: 09/26/2023]
Abstract
Indium tin oxide (ITO) is a semiconductor nanomaterial with broad application in liquid crystal displays, solar cells, and electrochemical immune sensors. It is worth noting that, with the gradual increase in worker exposure opportunities, the exposure risk in occupational production cannot be ignored. At present, the toxicity of ITO mainly focuses on respiratory toxicity. ITO inhaled through the upper respiratory tract can cause pathological changes such as interstitial pneumonia and pulmonary fibrosis. Still, extrapulmonary toxicity after nanoscale ITO nanoparticle (ITO NPs) exposure, such as long-term effects on the central nervous system, should also be of concern. Therefore, we set up exposure dose experiments (0 mg·kg-1, 3.6 mg·kg-1, and 36 mg·kg-1) based on occupational exposure limits to treat C57BL/6 mice via nasal drops for 15 weeks. Moreover, we conducted a preliminary assessment of the neurotoxicity of ITO NPs (20-30 nm) in vivo. The results indicated that ITO NPs can cause diffuse inflammatory infiltrates in brain tissue, increased glial cell responsiveness, abnormal neuronal cell lineage transition, neuronal migration disorders, and neuronal apoptosis related to the oxidative stress induced by ITO NPs exposure. Hence, our findings provide useful information for the fuller risk assessment of ITO NPs after occupational exposure.
Collapse
Affiliation(s)
- Yanting Pang
- Key Laboratory of Environmental Medicine Engineering, Ministry of Education, School of Public Health, Southeast University, Nanjing 210009, China
| | - Jing Qu
- Key Laboratory of Environmental Medicine Engineering, Ministry of Education, School of Public Health, Southeast University, Nanjing 210009, China
| | - Haopeng Zhang
- Key Laboratory of Environmental Medicine Engineering, Ministry of Education, School of Public Health, Southeast University, Nanjing 210009, China
| | - Yuna Cao
- Key Laboratory of Environmental Medicine Engineering, Ministry of Education, School of Public Health, Southeast University, Nanjing 210009, China
| | - Xinmo Ma
- Key Laboratory of Environmental Medicine Engineering, Ministry of Education, School of Public Health, Southeast University, Nanjing 210009, China
| | - Shile Wang
- Key Laboratory of Environmental Medicine Engineering, Ministry of Education, School of Public Health, Southeast University, Nanjing 210009, China
| | - Jianli Wang
- Key Laboratory of Environmental Medicine Engineering, Ministry of Education, School of Public Health, Southeast University, Nanjing 210009, China
| | - Jingying Wu
- Key Laboratory of Environmental Medicine Engineering, Ministry of Education, School of Public Health, Southeast University, Nanjing 210009, China
| | - Ting Zhang
- Key Laboratory of Environmental Medicine Engineering, Ministry of Education, School of Public Health, Southeast University, Nanjing 210009, China.
| |
Collapse
|
5
|
Zhang MX, Verhoeven F, Ravensbergen P, Kooij S, Geoffrion R, Bonn D, van Rijn CJM. Improved Olfactory Deposition of Theophylline Using a Nanotech Soft Mist Nozzle Chip. Pharmaceutics 2023; 16:2. [PMID: 38276480 PMCID: PMC10821129 DOI: 10.3390/pharmaceutics16010002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2023] [Revised: 12/13/2023] [Accepted: 12/14/2023] [Indexed: 01/27/2024] Open
Abstract
Currently, nasal administration of active pharmaceutical ingredients is most commonly performed using swirl-nozzle-based pump devices or pressurized syringes. However, they lead to limited deposition in the more active regions of the nasal cavity, especially the olfactory region, which is crucial for nose-to-brain drug delivery. This research proposes to improve deposition in the olfactory region by replacing the swirl nozzle with a nanoengineered nozzle chip containing micrometer-sized holes, which generates smaller droplets of 10-50 μm travelling at a lower plume velocity. Two nanotech nozzle chips with different hole sizes were tested at different inhalation flow rates to examine the deposition patterns of theophylline, a hyposmia treatment formulation, using a nasal cavity model. A user study was also conducted and showed that the patient instructions influenced the inhalation flow rate characteristics. Targeted flow rates of between 0 and 25 L/min were used for the in vitro deposition study, yielding 21.5-31.5% olfactory coverage. In contrast, the traditional swirl nozzle provided only 10.8% coverage at a similar flow rate. This work highlights the potential of the nanotech soft mist nozzle for improved intranasal drug delivery, particularly to the olfactory region.
Collapse
Affiliation(s)
- Madeline X. Zhang
- Van der Waals-Zeeman Institute, Institute of Physics, University of Amsterdam, 1098 XH Amsterdam, The Netherlands; (S.K.); (D.B.); (C.J.M.v.R.)
| | - Frank Verhoeven
- Medspray B.V., 7521 PV Enschede, The Netherlands; (F.V.); (P.R.)
| | | | - Stefan Kooij
- Van der Waals-Zeeman Institute, Institute of Physics, University of Amsterdam, 1098 XH Amsterdam, The Netherlands; (S.K.); (D.B.); (C.J.M.v.R.)
| | | | - Daniel Bonn
- Van der Waals-Zeeman Institute, Institute of Physics, University of Amsterdam, 1098 XH Amsterdam, The Netherlands; (S.K.); (D.B.); (C.J.M.v.R.)
| | - Cees J. M. van Rijn
- Van der Waals-Zeeman Institute, Institute of Physics, University of Amsterdam, 1098 XH Amsterdam, The Netherlands; (S.K.); (D.B.); (C.J.M.v.R.)
| |
Collapse
|
6
|
Liu Y, Wu D. Bi-directional nasal drug delivery systems: A scoping review of nasal particle deposition patterns and clinical application. Laryngoscope Investig Otolaryngol 2023; 8:1484-1499. [PMID: 38130248 PMCID: PMC10731484 DOI: 10.1002/lio2.1190] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2023] [Revised: 10/24/2023] [Accepted: 11/15/2023] [Indexed: 12/23/2023] Open
Abstract
Objectives To compare the deposition patterns within the nasal cavity between the bi-directional and unilateral nasal delivery systems. And to summarize the clinical application of the bi-directional nasal drug delivery devices. Data source PubMed, Cochrane Library, Embase, and Web of Science databases. Methods A scoping review was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA). We included studies exploring patterns and influencing factors of particle depositions within the nasal cavity among patients, healthy controls, and nose cast models using the bi-directional and unilateral nasal delivery system. The clinical application of the bi-directional delivery devices was also summarized. Results A total of 24 studies were included in this review. Bi-directional nasal delivery systems utilize forced exhalation to power the delivery of drugs to deeper areas of the nasal cavity and paranasal sinuses. Unilateral nasal delivery systems included traditional liquid spray pumps, the aerosol mask system, nebulization, and conventional nasal inhalation. Compared with unilateral delivery systems, the bi-directional nasal delivery system provided a more extensive and efficient nasal deposition in the nasal cavity, especially in the olfactory cleft, without lung deposition. Several parameters, including particle size, pulsatile flow, and nasal geometry, could significantly influence nasal deposition. The bi-directional nasal delivery system enables better delivery of steroids or sumatriptan to the sinonasal cavity's high and deep target sites. This bi-directional delivery device demonstrated an effective and well-tolerated treatment that produced high drug utilization, rapid absorption, and sustained symptom improvement among patients with chronic rhinosinusitis (CRS) or migraine. Conclusion The bi-directional nasal drug delivery systems demonstrated significantly higher drug deposition in superior and posterior regions of the nasal cavity than unilateral nasal delivery systems. Further studies should explore its potential role in delivering drugs to the olfactory cleft among patients with olfactory disorders and central nervous system diseases. Level of evidence N/A.
Collapse
Affiliation(s)
- Yuxing Liu
- Department of Otolaryngology‐Head and Neck SurgeryPeking University Third HospitalBeijingPR China
- Department of MedicinePeking UniversityBeijingPR China
| | - Dawei Wu
- Department of Otolaryngology‐Head and Neck SurgeryPeking University Third HospitalBeijingPR China
| |
Collapse
|
7
|
Rigaut C, Deruyver L, Niesen M, Vander Ghinst M, Goole J, Lambert P, Haut B. What Are the Key Anatomical Features for the Success of Nose-to-Brain Delivery? A Study of Powder Deposition in 3D-Printed Nasal Casts. Pharmaceutics 2023; 15:2661. [PMID: 38140002 PMCID: PMC10747338 DOI: 10.3390/pharmaceutics15122661] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2023] [Revised: 11/08/2023] [Accepted: 11/21/2023] [Indexed: 12/24/2023] Open
Abstract
Nose-to-brain delivery is a promising way to improve the treatment of central nervous system disorders, as it allows the bypassing of the blood-brain barrier. However, it is still largely unknown how the anatomy of the nose can influence the treatment outcome. In this work, we used 3D printing to produce nasal replicas based on 11 different CT scans presenting various anatomical features. Then, for each anatomy and using the Design of Experiments methodology, we characterised the amount of a powder deposited in the olfactory region of the replica as a function of multiple parameters (choice of the nostril, device, orientation angle, and the presence or not of a concomitant inspiration flow). We found that, for each anatomy, the maximum amount of powder that can be deposited in the olfactory region is directly proportional to the total area of this region. More precisely, the results show that, whatever the instillation strategy, if the total area of the olfactory region is below 1500 mm2, no more than 25% of an instilled powder can reach this region. On the other hand, if the total area of the olfactory region is above 3000 mm2, the deposition efficiency reaches 50% with the optimal choice of parameters, whatever the other anatomical characteristics of the nasal cavity. Finally, if the relative difference between the areas of the two sides of the internal nasal valve is larger than 20%, it becomes important to carefully choose the side of instillation. This work, by predicting the amount of powder reaching the olfactory region, provides a tool to evaluate the adequacy of nose-to-brain treatment for a given patient. While the conclusions should be confirmed via in vivo studies, it is a first step towards personalised treatment of neurological pathologies.
Collapse
Affiliation(s)
- Clément Rigaut
- Transfers Interfaces and Processes (TIPs), École Polytechnique de Bruxelles, Université Libre de Bruxelles, 1050 Brussels, Belgium; (P.L.); (B.H.)
| | - Laura Deruyver
- Laboratoire de Pharmacie Galénique et Biopharmacie, Faculté de Pharmacie, Université Libre de Bruxelles, 1050 Brussels, Belgium; (L.D.); (J.G.)
| | - Maxime Niesen
- Department of Ear, Nose and Throat and Cervico-Facial Surgery, CUB Hôpital Erasme, Hôpital de Bruxelles (HUB), 1070 Brussels, Belgium; (M.N.); (M.V.G.)
| | - Marc Vander Ghinst
- Department of Ear, Nose and Throat and Cervico-Facial Surgery, CUB Hôpital Erasme, Hôpital de Bruxelles (HUB), 1070 Brussels, Belgium; (M.N.); (M.V.G.)
| | - Jonathan Goole
- Laboratoire de Pharmacie Galénique et Biopharmacie, Faculté de Pharmacie, Université Libre de Bruxelles, 1050 Brussels, Belgium; (L.D.); (J.G.)
| | - Pierre Lambert
- Transfers Interfaces and Processes (TIPs), École Polytechnique de Bruxelles, Université Libre de Bruxelles, 1050 Brussels, Belgium; (P.L.); (B.H.)
| | - Benoit Haut
- Transfers Interfaces and Processes (TIPs), École Polytechnique de Bruxelles, Université Libre de Bruxelles, 1050 Brussels, Belgium; (P.L.); (B.H.)
| |
Collapse
|
8
|
van Vliet EF, Knol MJ, Schiffelers RM, Caiazzo M, Fens MHAM. Levodopa-loaded nanoparticles for the treatment of Parkinson's disease. J Control Release 2023; 360:212-224. [PMID: 37343725 DOI: 10.1016/j.jconrel.2023.06.026] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2022] [Revised: 06/15/2023] [Accepted: 06/18/2023] [Indexed: 06/23/2023]
Abstract
Parkinson's disease (PD) is a neurodegenerative disorder characterized by degeneration of dopaminergic neurons in the substantia nigra pars compacta (SNpc) resulting in dopamine (DA) deficiency, which manifests itself in motor symptoms including tremors, rigidity and bradykinesia. Current PD treatments aim at symptom reduction through oral delivery of levodopa (L-DOPA), a precursor of DA. However, L-DOPA delivery to the brain is inefficient and increased dosages are required as the disease progresses, resulting in serious side effects like dyskinesias. To improve PD treatment efficacy and to reduce side effects, recent research focuses on the encapsulation of L-DOPA into polymeric- and lipid-based nanoparticles (NPs). These formulations can protect L-DOPA from systemic decarboxylation into DA and improve L-DOPA delivery to the central nervous system. Additionally, NPs can be modified with proteins, peptides and antibodies specifically targeting the blood-brain barrier (BBB), thereby reducing required dosages and free systemic DA. Alternative delivery approaches for NP-encapsulated L-DOPA include intravenous (IV) administration, transdermal delivery using adhesive patches and direct intranasal administration, facilitating increased therapeutic DA concentrations in the brain. This review provides an overview of the recent advances for NP-mediated L-DOPA delivery to the brain, and debates challenges and future perspectives on the field.
Collapse
Affiliation(s)
- Emile F van Vliet
- Department of Pharmaceutics, Utrecht Institute for Pharmaceutical Sciences, Utrecht University, 3584 CG Utrecht, the Netherlands
| | - Maarten J Knol
- Department of Pharmaceutics, Utrecht Institute for Pharmaceutical Sciences, Utrecht University, 3584 CG Utrecht, the Netherlands
| | | | - Massimiliano Caiazzo
- Department of Pharmaceutics, Utrecht Institute for Pharmaceutical Sciences, Utrecht University, 3584 CG Utrecht, the Netherlands; Department of Molecular Medicine and Medical Biotechnology, University of Naples "Federico II", Via Pansini 5, 80131 Naples, Italy.
| | - Marcel H A M Fens
- Department of Pharmaceutics, Utrecht Institute for Pharmaceutical Sciences, Utrecht University, 3584 CG Utrecht, the Netherlands.
| |
Collapse
|
9
|
Usman Khan M, Cai X, Shen Z, Mekonnen T, Kourmatzis A, Cheng S, Gholizadeh H. Challenges in the Development and Application of Organ-on-Chips for Intranasal Drug Delivery Studies. Pharmaceutics 2023; 15:pharmaceutics15051557. [PMID: 37242799 DOI: 10.3390/pharmaceutics15051557] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2023] [Revised: 05/12/2023] [Accepted: 05/14/2023] [Indexed: 05/28/2023] Open
Abstract
With the growing demand for the development of intranasal (IN) products, such as nasal vaccines, which has been especially highlighted during the COVID-19 pandemic, the lack of novel technologies to accurately test the safety and effectiveness of IN products in vitro so that they can be delivered promptly to the market is critically acknowledged. There have been attempts to manufacture anatomically relevant 3D replicas of the human nasal cavity for in vitro IN drug tests, and a couple of organ-on-chip (OoC) models, which mimic some key features of the nasal mucosa, have been proposed. However, these models are still in their infancy, and have not completely recapitulated the critical characteristics of the human nasal mucosa, including its biological interactions with other organs, to provide a reliable platform for preclinical IN drug tests. While the promising potential of OoCs for drug testing and development is being extensively investigated in recent research, the applicability of this technology for IN drug tests has barely been explored. This review aims to highlight the importance of using OoC models for in vitro IN drug tests and their potential applications in IN drug development by covering the background information on the wide usage of IN drugs and their common side effects where some classical examples of each area are pointed out. Specifically, this review focuses on the major challenges of developing advanced OoC technology and discusses the need to mimic the physiological and anatomical features of the nasal cavity and nasal mucosa, the performance of relevant drug safety assays, as well as the fabrication and operational aspects, with the ultimate goal to highlight the much-needed consensus, to converge the effort of the research community in this area of work.
Collapse
Affiliation(s)
| | - Xinyu Cai
- School of Engineering, Macquarie University, Sydney, NSW 2113, Australia
| | - Zhiwei Shen
- School of Engineering, Macquarie University, Sydney, NSW 2113, Australia
| | - Taye Mekonnen
- School of Aerospace, Mechanical and Mechatronic Engineering, The University of Sydney, Sydney, NSW 2006, Australia
| | - Agisilaos Kourmatzis
- School of Aerospace, Mechanical and Mechatronic Engineering, The University of Sydney, Sydney, NSW 2006, Australia
| | - Shaokoon Cheng
- School of Engineering, Macquarie University, Sydney, NSW 2113, Australia
| | - Hanieh Gholizadeh
- Division of Pulmonary, Allergy and Critical Care Medicine, Department of Medicine, University of Pittsburgh, Pittsburgh, PA 15213, USA
| |
Collapse
|
10
|
Deruyver L, Rigaut C, Gomez-Perez A, Lambert P, Haut B, Goole J. In vitro Evaluation of Paliperidone Palmitate Loaded Cubosomes Effective for Nasal-to-Brain Delivery. Int J Nanomedicine 2023; 18:1085-1106. [PMID: 36883068 PMCID: PMC9985876 DOI: 10.2147/ijn.s397650] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2022] [Accepted: 02/01/2023] [Indexed: 03/05/2023] Open
Abstract
Introduction This work aimed to develop chitosan-coated cubosomal nanoparticles intended for nose-to-brain delivery of paliperidone palmitate. They were compared with standard and cationic cubosomal nanoparticles. This comparison relies on numerous classical in vitro tests and powder deposition within a 3D-printed nasal cast. Methods Cubosomal nanoparticles were prepared by a Bottom-up method followed by a spray drying process. We evaluated their particle size, polydispersity index, zeta-potential, encapsulation efficiency, drug loading, mucoaffinity properties and morphology. The RPMI 2650 cell line was used to assess the cytotoxicity and cellular permeation. An in vitro deposition test within a nasal cast completed these measurements. Results The selected chitosan-coated cubosomal nanoparticles loaded with paliperidone palmitate had a size of 305.7 ± 22.54 nm, their polydispersity index was 0.166 ± 0.022 and their zeta potential was +42.4 ± 0.2 mV. This formulation had a drug loading of 70% and an encapsulation efficiency of 99.7 ± 0.1%. Its affinity with mucins was characterized by a ΔZP of 20.93 ± 0.31. Its apparent permeability coefficient thought the RPMI 2650 cell line was 3.00E-05 ± 0.24E-05 cm/s. After instillation in a 3D-printed nasal cast, the fraction of the injected powder deposited in the olfactory region reached 51.47 ± 9.30% in the right nostril and 41.20 ± 4.59% in the left nostril, respectively. Conclusion The chitosan coated cubosomal formulation seems to be the most promising formulation for nose-to-brain delivery. Indeed, it has a high mucoaffinity and a significantly higher apparent permeability coefficient than the two other formulations. Finally, it reaches well the olfactory region.
Collapse
Affiliation(s)
- Laura Deruyver
- Laboratoire de Pharmacie Galénique et Biopharmacie, Faculté de pharmacie, Université libre de Bruxelles, Brussels, Belgium
| | - Clément Rigaut
- Transfers, Interfaces and Processes (TIPs), École Polytechnique de Bruxelles, Université libre de Bruxelles, Brussels, Belgium
| | | | - Pierre Lambert
- Transfers, Interfaces and Processes (TIPs), École Polytechnique de Bruxelles, Université libre de Bruxelles, Brussels, Belgium
| | - Benoit Haut
- Transfers, Interfaces and Processes (TIPs), École Polytechnique de Bruxelles, Université libre de Bruxelles, Brussels, Belgium
| | - Jonathan Goole
- Laboratoire de Pharmacie Galénique et Biopharmacie, Faculté de pharmacie, Université libre de Bruxelles, Brussels, Belgium
| |
Collapse
|
11
|
Chavda VP, Jogi G, Shah N, Athalye MN, Bamaniya N, K Vora L, Cláudia Paiva-Santos A. Advanced particulate carrier-mediated technologies for nasal drug delivery. J Drug Deliv Sci Technol 2022. [DOI: 10.1016/j.jddst.2022.103569] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/09/2022]
|
12
|
Rigaut C, Deruyver L, Goole J, Haut B, Lambert P. Instillation of a Dry Powder in Nasal Casts: Parameters Influencing the Olfactory Deposition With Uni- and Bi-Directional Devices. FRONTIERS IN MEDICAL TECHNOLOGY 2022; 4:924501. [PMID: 35832236 PMCID: PMC9273033 DOI: 10.3389/fmedt.2022.924501] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2022] [Accepted: 05/26/2022] [Indexed: 01/04/2023] Open
Abstract
Nose-to-brain delivery is a promising way to reach the central nervous system with therapeutic drugs. However, the location of the olfactory region at the top of the nasal cavity complexifies this route of administration. In this study, we used a 3D-printed replica of a nasal cavity (a so-called “nasal cast”) to reproduce in vitro the deposition of a solid powder. We considered two different delivery devices: a unidirectional device generating a classical spray and a bidirectional device that relies on the user expiration. A new artificial mucus also coated the replica. Five parameters were varied to measure their influence on the powder deposition pattern in the olfactory region of the cast: the administration device, the instillation angle and side, the presence of a septum perforation, and the flow rate of possible concomitant inspiration. We found that the unidirectional powder device is more effective in targeting the olfactory zone than the bi-directional device. Also, aiming the spray nozzle directly at the olfactory area is more effective than targeting the center of the nasal valve. Moreover, the choice of the nostril and the presence of a perforation in the septum also significantly influence the olfactory deposition. On the contrary, the inspiratory flow has only a minor effect on the powder outcome. By selecting the more efficient administration device and parameters, 44% of the powder can reach the olfactory region of the nasal cast.
Collapse
Affiliation(s)
- Clément Rigaut
- Transfers, Interfaces and Processes (TIPs), École Polytechnique de Bruxelles, Université Libre de Bruxelles, Brussels, Belgium
| | - Laura Deruyver
- Laboratoire de Pharmacie Galénique et Biopharmacie, Faculté de Pharmacie, Université Libre de Bruxelles, Brussels, Belgium
| | - Jonathan Goole
- Laboratoire de Pharmacie Galénique et Biopharmacie, Faculté de Pharmacie, Université Libre de Bruxelles, Brussels, Belgium
| | - Benoît Haut
- Transfers, Interfaces and Processes (TIPs), École Polytechnique de Bruxelles, Université Libre de Bruxelles, Brussels, Belgium
| | - Pierre Lambert
- Transfers, Interfaces and Processes (TIPs), École Polytechnique de Bruxelles, Université Libre de Bruxelles, Brussels, Belgium
| |
Collapse
|
13
|
Micro- and Nanosized Carriers for Nose-to-Brain Drug Delivery in Neurodegenerative Disorders. Biomedicines 2022; 10:biomedicines10071706. [PMID: 35885011 PMCID: PMC9313014 DOI: 10.3390/biomedicines10071706] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2022] [Revised: 07/06/2022] [Accepted: 07/12/2022] [Indexed: 12/12/2022] Open
Abstract
Neurodegenerative disorders (NDs) have become a serious health problem worldwide due to the rapid increase in the number of people that are affected and the constantly aging population. Among all NDs, Alzheimer’s and Parkinson’s disease are the most common, and many efforts have been made in the development of effective and reliable therapeutic strategies. The intranasal route of drug administration offers numerous advantages, such as bypassing the blood–brain barrier and providing a direct entrance to the brain through the olfactory and trigeminal neurons. The present review summarizes the available information on recent advances in micro- and nanoscale nose-to-brain drug-delivery systems as a novel strategy for the treatment of Alzheimer’s and Parkinson’s disease. Specifically, polymer- and lipid-base micro- and nanoparticles have been studied as a feasible approach to increase the brain bioavailability of certain drugs. Furthermore, nanocomposites are discussed as a suitable formulation for administration into the nasal cavity.
Collapse
|
14
|
Abstract
Drug delivery via the pulmonary route is a cornerstone in the pharmaceutical sector as an alternative to oral and parenteral administration. Nebulizer inhalation treatment offers multiple drug administration, easily employed with tidal breathing, suitable for children and elderly, can be adapted for severe patients and visible spray ensures patient satisfaction. This review discusses the operational and mechanical characteristics of nebulizer delivery devices in terms of aerosol production processes, their usage, benefits and drawbacks that are currently shaping the contemporary landscape of inhaled drug delivery. With the advent of particle engineering, novel inhaled nanosystems can be successfully developed to increase lung deposition and decrease pulmonary clearance. The above-mentioned advances might pave the path for treating a life-threatening disorder like severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) which is also discussed in the current state of the art.
Collapse
|
15
|
Deruyver L, Rigaut C, Lambert P, Haut B, Goole J. The importance of pre-formulation studies and of 3D-printed nasal casts in the success of a pharmaceutical product intended for nose-to-brain delivery. Adv Drug Deliv Rev 2021; 175:113826. [PMID: 34119575 DOI: 10.1016/j.addr.2021.113826] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2021] [Revised: 05/19/2021] [Accepted: 06/07/2021] [Indexed: 02/08/2023]
Abstract
This review aims to cement three hot topics in drug delivery: (a) the pre-formulation of new products intended for nose-to-brain delivery; (b) the development of nasal casts for studying the efficacy of potential new nose-to-brain delivery systems at the early of their development (pre-formulation); (c) the use of 3D printing based on a wide variety of materials (transparent, biocompatible, flexible) providing an unprecedented fabrication tool towards personalized medicine by printing nasal cast on-demand based on CT scans of patients. This review intends to show the links between these three subjects. Indeed, the pathway selected to administrate the drug to the brain not only influence the formulation strategies to implement but also the design of the cast, to get the most convincing measures from it. Moreover, the design of the cast himself influences the choice of the 3D-printing technology, which, in its turn, bring more constraints to the nasal replica design. Consequently, the formulation of the drug, the cast preparation and its realisation should be thought of as a whole and not separately.
Collapse
Affiliation(s)
- Laura Deruyver
- Laboratoire de Pharmacie Galénique et de Biopharmacie, Université libre de Bruxelles (ULB), Brussels, Belgium
| | - Clément Rigaut
- TIPs (Transfers, Interfaces and Processes), Université libre de Bruxelles, Brussels, Belgium
| | - Pierre Lambert
- TIPs (Transfers, Interfaces and Processes), Université libre de Bruxelles, Brussels, Belgium
| | - Benoît Haut
- TIPs (Transfers, Interfaces and Processes), Université libre de Bruxelles, Brussels, Belgium
| | - Jonathan Goole
- Laboratoire de Pharmacie Galénique et de Biopharmacie, Université libre de Bruxelles (ULB), Brussels, Belgium.
| |
Collapse
|
16
|
Can computational fluid dynamic models help us in the treatment of chronic rhinosinusitis. Curr Opin Otolaryngol Head Neck Surg 2020; 29:21-26. [PMID: 33315616 DOI: 10.1097/moo.0000000000000682] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE OF REVIEW The aim of this study was to review the recent literature (January 2017-July 2020) on computational fluid dynamics (CFD) studies relating to chronic rhinosinusitis (CRS), including airflow within the pre and postoperative sinonasal cavity, virtual surgery, topical drug and saline delivery (sprays, nebulizers and rinses) and olfaction. RECENT FINDINGS Novel CFD-specific parameters (heat flux and wall shear stress) are highly correlated with patient perception of nasal patency. Increased ostial size markedly improves sinus ventilation and drug delivery. New virtual surgery tools allow surgeons to optimize interventions. Sinus deposition of nasal sprays is more effective with smaller, low-inertia particles, outside of the range produced by many commercially available products. Saline irrigation effectiveness is improved using greater volume, with liquid entering sinuses via 'flooding' of ostia rather than direct jet entry. SUMMARY CFD has provided new insights into sinonasal airflow, air-conditioning function, the nasal cycle, novel measures of nasal patency and the impact of polyps and sinus surgery on olfaction. The deposition efficiency of topical medications on sinus mucosa can be markedly improved through parametric CFD experiments by optimising nasal spray particle size and velocity, nozzle angle and insertion location, while saline irrigation effectiveness can be optimized by modelling squeeze bottle volume and head position. More sophisticated CFD models (inhalation and exhalation, spray particle and saline irrigation) will increasingly provide translational benefits in the clinical management of CRS.
Collapse
|