1
|
Zhang C, Li J, Suo H, Bai J. Non-fixation versus fixation of mesh in laparoscopic transabdominal preperitoneal repair of inguinal hernia: A systematic review and meta-analysis of randomized controlled trials. PLoS One 2024; 19:e0314334. [PMID: 39642172 PMCID: PMC11623461 DOI: 10.1371/journal.pone.0314334] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2024] [Accepted: 11/10/2024] [Indexed: 12/08/2024] Open
Abstract
PURPOSE The impact of non-fixation of mesh in transabdominal preperitoneal (TAPP) inguinal hernia repair has not been fully assessed. The aim of this meta-analysis was to comprehensively compare the clinical outcomes of non-fixation and fixation of mesh in TAPP to determine whether non-fixation could affect the outcomes. METHODS PubMed, Embase and CENTRAL were searched for studies on TAPP repair of inguinal hernia and mesh fixation published up to June 2023. The literature search was completed on June 22, 2023. Randomized controlled trials that compared perioperative outcomes between mesh fixation and non-fixation without using self-gripping mesh were included. The primary outcome measures were recurrence and evaluation of postoperative pain, while secondary outcome measures included time to normal activity, infection rate and formation of seroma. Subgroup analyses and sensitivity analysis were also conducted. RESULTS Six randomized controlled trials were included, involving 679 patients who underwent TAPP with non-fixation and 964 patients with fixation of mesh. There was no significant difference in recurrence between the two groups (RR: 0.83; 95% CI, 0.29-2.39, P = 0.73). The non-fixation group had less pain than the fixation group at 6 months postoperatively (MD: -0.16; 95% CI, -0.23--0.10, P < 0.0001). Additionally, there was no significant difference in the time to return to normal activity or rates of infection or seroma formation between the two groups (MD: -4.95; 95% CI, -11.36-1.45, P = 0.13; RR: 1.18; 95% CI, 0.39-3.62, P = 0.77; RR: 0.94; 95% CI, 0.63-1.40, P = 0.75). CONCLUSION Based on the current evidence, non-fixation without using self-gripping mesh may not affect the efficacy of TAPP. It does not increase recurrence rate and may result in less postoperative pain in inguinal hernia with small hernia defect (less than 3cm).
Collapse
Affiliation(s)
- ChenXin Zhang
- Department of General Surgery, The 983rd Hospital of Joint Logistic Support Force of PLA, Tianjin, China
| | - Jia Li
- Department of Gastroenterology, The 983rd Hospital of Joint Logistic Support Force of PLA, Tianjin, China
| | - HaiJin Suo
- Department of General Surgery, The 983rd Hospital of Joint Logistic Support Force of PLA, Tianjin, China
| | - JianPing Bai
- Department of General Surgery, The 983rd Hospital of Joint Logistic Support Force of PLA, Tianjin, China
| |
Collapse
|
2
|
Nagata S, Orita H, Korenaga D. Nonfixation of mesh in laparoscopic totally extraperitoneal inguinal hernia repair: A propensity score matched analysis. Asian J Surg 2022:S1015-9584(22)01410-5. [DOI: 10.1016/j.asjsur.2022.09.131] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2022] [Revised: 09/19/2022] [Accepted: 09/28/2022] [Indexed: 12/23/2022] Open
|
3
|
Initial experience using a handheld fully articulating software-driven laparoscopic needle driver in TAPP inguinal hernia repair. Surg Endosc 2021; 35:3221-3231. [PMID: 33825010 PMCID: PMC8116294 DOI: 10.1007/s00464-021-08446-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2020] [Accepted: 03/08/2021] [Indexed: 11/18/2022]
Abstract
Background The laparoscopic transabdominal preperitoneal (TAPP) inguinal hernia repair is a widely performed minimally invasive operation, but can present considerable ergonomic challenges for the surgeon. Our objective was to determine if a novel handheld software-driven laparoscopic articulating needle driver can mitigate these difficulties. Methods The video recordings of a consecutive series of TAPP cases by a single surgeon using the articulating device were compared with a series of cases using straight-stick laparoscopy. Two critical steps of the procedure were analyzed for time: mesh fixation and peritoneal suture closure. These steps were then compared before and after 10 initial consecutive cases to analyze whether the surgeon demonstrated improvement. A cost analysis was also performed between the two techniques. Results For mesh fixation, the surgeon averaged 227 s using tacker devices, compared with 462.4 s using the novel laparoscopic device (p = 0.06). For the peritoneal closure component of the operation, the surgeon improved the time per suture pass during closure from 60.61 s during the first 10 cases to 38.84 s after the first 10 cases (p = 0.0004), which was comparable to the time per stitch for standard laparoscopy (34.8 s vs 34.84 s, p = 0.997). Left-sided inguinal hernia repairs using the articulating device demonstrated a significantly longer time per stitch during peritoneal closure compared to the right side after first 10 cases (left: 40.62 s; right: 27.91, p = 0.005). Our direct cost analysis demonstrated that suture closure of the peritoneum using the articulating device was more cost-effective than tack fixation. Conclusions After only a 10 case initial experience, a laparoscopic hand-held articulating needle driver is comparable to standard laparoscopy to complete suture mesh fixation and peritoneal closure for TAPP inguinal hernia repair. Further, the feasibility of suture mesh fixation minimizes the need for costly tacker devices. This instrument appears to be a promising tool in this largely minimally invasive era of hernia repair.
Collapse
|
4
|
Sugumar K, Nandy K, Rege S, Deshpande A. A prospective cohort study in laparoscopic inguinal hernia repair: Mesh fixation versus nonfixation. Niger J Surg 2021. [DOI: 10.4103/njs.njs_30_20] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
|
5
|
Mesh fixation using novel bio-adhesive coating compared to tack fixation for IPOM hernia repair: in vivo evaluation in a porcine model. Surg Endosc 2019; 33:2364-2375. [PMID: 31069501 DOI: 10.1007/s00464-019-06806-x] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2018] [Accepted: 04/29/2019] [Indexed: 12/31/2022]
Abstract
BACKGROUND Mesh fixation in hernia repair is currently based on penetrating sutures or anchors, with proven early and late complications such as pain, adhesions, erosions, and anchor migration. In an attempt to reduce these complications, a bio-adhesive-based self-fixation system was developed. The purpose of this study was to assess the performance and safety of this novel self-adhesive mesh (LifeMesh™) by comparing it with standard tack fixation. METHODS A full-thickness abdominal wall defect was created bilaterally in 24 pigs. The defects were measured 14 days later, and laparoscopic intraperitoneal onlay mesh (IPOM) repairs were performed. In each animal, both LifeMesh and a titanium tack-fixed control, either uncoated polypropylene mesh (PP) or composite mesh (Symbotex™), were used. After 28 and 90 days, we performed macroscopic evaluation and analyzed the fixation strength, shrinkage, adhesion scores, and histopathology in all samples. RESULTS Measurements at both time points revealed that LifeMesh had fully conformed to the abdominal wall, and that its fixation strength was superior to that of the tack-fixated Symbotex and comparable to that of the tack-fixated PP. Shrinkage in all groups was similar. Adhesion scores with LifeMesh were lower than with PP and comparable with Symbotex at both time points. Histology demonstrated similar tissue responses in LifeMesh and Symbotex. Lack of necrosis, mineralization, or exuberant inflammatory reaction in all three groups pointed to their good progressive integration of the mesh to the abdominal wall. By 28 days the bio-adhesive layer in LifeMesh was substantially degraded, allowing a gradual tissue ingrowth that became the main fixation mode of this mesh to the abdominal wall. CONCLUSIONS The excellent incorporation of LifeMesh to the abdominal wall and its superior fixation strength, together with its low adhesion score, suggest that LifeMesh may become a preferred alternative for abdominal wall repair.
Collapse
|
6
|
Kumar A, Pal AK, Choudhary A, Anand A, Sonkar AA, Pahwa HS. Transfascial suture versus tack fixation of mesh in totally extraperitoneal repair of inguinal hernia: A prospective comparative study. J Minim Access Surg 2019; 16:132-137. [PMID: 30777988 PMCID: PMC7176006 DOI: 10.4103/jmas.jmas_192_18] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023] Open
Abstract
Purpose: Among laparoscopic surgeries in inguinal hernias, totally extraperitoneal (TEP) repair has demonstrated favourable results in reduction of post-operative pain and mean operative times with early return to physical activity. We have done a prospective comparative study on two different techniques of mesh fixation, i.e., transfascial suture and tack fixation. Materials and Methods: It was a prospective, non-randomised comparative study done on inguinal hernia patients operated by TEP repair from October 2014 to September 2016. These data were compared in two techniques of mesh fixation (tack and transfascial sutures) in terms of post-operative complications, pain scores by visual analogue scale (VAS) and cost analysis of the procedure. Results: Our study on 69 total patients (44 tack fixation and 25 suture fixation group) revealed that mean VAS scores for post-operative pain were not having any statistically significant difference in the tack group versus suture group (2.42 ± 0.24 vs. 2.2 ± 0.24) at 24 h, but VAS scores in the follow-up period at 1 week, 1 month, 3 months and 6 months were 1.14 ± 0.33 versus 0.67 ± 0.27; 0.78 ± 0.24 versus 0.07 ± 0.06; 0.42 ± 0.17 versus 0.07 ± 0.06 and 0.5 ± 0.11 versus 0.07 ± 0.06, respectively, which showed significant difference at 1 and 3 months, suggesting less pain in the suture group. No significant difference was noted in other post-operative complications. Conclusion: Transfascial suture fixation of mesh in TEP repair of inguinal hernia can be a cost-effective procedure with a comparable safety profile as compared to tack fixation.
Collapse
Affiliation(s)
- Awanish Kumar
- Department of Surgery, King George Medical University, Lucknow, Uttar Pradesh, India
| | - Ajay Kumar Pal
- Department of Surgery, King George Medical University, Lucknow, Uttar Pradesh, India
| | - Anuraag Choudhary
- Department of Surgery, King George Medical University, Lucknow, Uttar Pradesh, India
| | - Akshay Anand
- Department of Surgery, King George Medical University, Lucknow, Uttar Pradesh, India
| | - Abhinav Arun Sonkar
- Department of Surgery, King George Medical University, Lucknow, Uttar Pradesh, India
| | - Harvinder Singh Pahwa
- Department of Surgery, King George Medical University, Lucknow, Uttar Pradesh, India
| |
Collapse
|
7
|
Nerve Surgery to Treat Intractable Genitofemoral Neuropathic Pain following Laparoscopic Live Kidney Donation. Case Rep Transplant 2018; 2018:9326975. [PMID: 29977640 PMCID: PMC6011110 DOI: 10.1155/2018/9326975] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2017] [Accepted: 04/18/2018] [Indexed: 11/17/2022] Open
Abstract
To date live laparoscopic donor nephrectomies (LLDN) are frequently performed. The most common complications entail bleeding, wound infection, and incisional hernia. Here we discuss a 50-year-old patient with a severe less known complication, namely, postoperative persistent neuropathic pain in the scrotum and left upper leg. Satisfactory pain control could not be obtained in 3 years of postoperative pain treatment which consisted of neuroleptic drugs, blocks of the L1/L2 dorsal roots with local anaesthetics, and pulsed radiofrequency lesioning. Exploratory laparoscopy was performed to assess the aspect of the genitofemoral nerve (GFN). A hemoclip used for the closure of the ureter at the time of nephrectomy was found in close relation to the GFN. The clip was removed and the GFN was subsequently cut proximal to the side of this clip. Soon after surgery the patient was completely pain-free and could return to his normal activities. Surgery should be considered in case of GFN neuropathic pain following LLDN.
Collapse
|
8
|
Mesh fixation methods and chronic pain after transabdominal preperitoneal (TAPP) inguinal hernia surgery: a comparison between fibrin sealant and tacks. Surg Endosc 2017; 31:4077-4084. [DOI: 10.1007/s00464-017-5454-8] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2016] [Accepted: 02/03/2017] [Indexed: 01/08/2023]
|
9
|
Tanoue K, Okino H, Kanazawa M, Ueno K. Single-incision laparoscopic transabdominal preperitoneal mesh hernioplasty: results in 182 Japanese patients. Hernia 2016; 20:797-803. [DOI: 10.1007/s10029-016-1540-4] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2015] [Accepted: 10/08/2016] [Indexed: 01/20/2023]
|
10
|
Shi Z, Fan X, Zhai S, Zhong X, Huang D. Fibrin glue versus staple for mesh fixation in laparoscopic transabdominal preperitoneal repair of inguinal hernia: a meta-analysis and systematic review. Surg Endosc 2016; 31:527-537. [PMID: 27351657 DOI: 10.1007/s00464-016-5039-y] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2016] [Accepted: 06/11/2016] [Indexed: 10/21/2022]
Abstract
BACKGROUND The aim of this study was to compare outcomes of mesh fixation using fibrin glue versus staple in laparoscopic transabdominal preperitoneal (TAPP) repair of inguinal hernia. METHODS AND PROCEDURES Database searches were carried out in PubMed, Embase, Cochrane Library, Web of Science and Cochrane databases until February 2016 using specific search terms. Studies which compared fibrin glue and staple for mesh fixation in laparoscopic transabdominal preperitoneal repair of inguinal hernia were enrolled. Outcomes, including inguinal hernia recurrence, chronic inguinal pain, seroma or hematoma formation and operating time, were measured. RESULTS Four randomized controlled trials (RCTs, 430 patients) and six non-randomized controlled trials (non-RCTs, 8637 patients) were analyzed. Meta-analysis of the four RCTs showed no significant difference in hernia recurrence (OR 2.10, 95 % CI 0.61, 7.22), seroma or hematoma formation (OR 0.55, 95 % CI 0.27, 1.14) and operating time (SMD 0.80, 95 % CI -0.34, 1.94). Similarly, there was no significant difference in most of the outcomes of the six non-RCTs. CONCLUSIONS Our meta-analysis and systematic review shows that the use of fibrin glue fixation may provide an alternative approach to staple fixation in TAPP inguinal hernia repair without increasing the postoperative morbidity. Large-scale RCTs with long-term follow-up are still needed to further assess postoperative outcomes such as chronic pain and disease recurrence.
Collapse
Affiliation(s)
- Zhaoqi Shi
- Department of General Surgery, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, 3 East Qingchun Rd, Hangzhou, 310016, China
| | - Xiaoxiao Fan
- Department of General Surgery, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, 3 East Qingchun Rd, Hangzhou, 310016, China
| | - Shuting Zhai
- Department of General Surgery, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, 3 East Qingchun Rd, Hangzhou, 310016, China
| | - Xin Zhong
- Department of General Surgery, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, 3 East Qingchun Rd, Hangzhou, 310016, China
| | - Diyu Huang
- Department of General Surgery, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, 3 East Qingchun Rd, Hangzhou, 310016, China.
| |
Collapse
|
11
|
Laparoscopic Partially Extraperitoneal (PEP) Mesh Repair for Laterally Placed Ventral and Incisional Hernias. Surg Laparosc Endosc Percutan Tech 2014; 24:e99-100. [DOI: 10.1097/sle.0b013e3182901480] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
12
|
Sajid MS, Farag S, Singh KK, Miles WFA. Systematic review and meta-analysis of published randomized controlled trials comparing the role of self-gripping mesh against suture mesh fixation in patients undergoing open inguinal hernia repair. Updates Surg 2013; 66:189-96. [DOI: 10.1007/s13304-013-0237-9] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2013] [Accepted: 10/08/2013] [Indexed: 10/26/2022]
|
13
|
Abstract
BACKGROUND AND OBJECTIVES Mesh fixation in laparoscopic umbilical hernia repair is poorly studied. We compared postoperative outcomes of laparoscopic umbilical hernia repair in suture versus tack mesh fixation. METHODS Patients who underwent laparoscopic umbilical hernia repair were separated by method of mesh fixation: sutures versus primarily tacks. Medical history and follow-up data were collected through medical records. The primary outcome of this study was the recurrence rates of hernias. Postoperative major and minor complications, such as surgical site infection, small-bowel obstruction, and seroma formation, were regarded as secondary outcomes. Additionally, a telephone interview was conducted to assess postoperative pain, recovery time, and overall patient satisfaction. RESULTS Eighty-six patients were identified: 33 in the suture group and 53 in the tacks group. The number of emergent cases was increased in the tacks group (6 vs 0; P = .022). Mean follow-up time was 2.7 years for both groups. Documented postoperative follow-up was obtained in 29 (90%) suture group and 31 (58%) tacks group patients. Hernia recurrence occurred in 3 and 2 patients in the sutures and tacks groups, respectively (P was not significant). No differences were found in secondary outcomes, including subjective outcomes from telephone interviews, between groups. CONCLUSIONS There are no differences in postoperative complication rates in suture versus tack mesh fixation in laparoscopic umbilical hernia repair.
Collapse
Affiliation(s)
| | - Jacqueline Choi
- Department of Surgery, Mount Sinai Hospital, New York, NY, USA
| | - Elizabeth Lynn
- Department of Surgery, Mount Sinai Hospital, New York, NY, USA
| | - Celia M Divino
- Department of Surgery, Mount Sinai Hospital, One Gustave L. Levy Place, Box 1259, 5th Floor, New York, NY 10029.
| |
Collapse
|
14
|
Sajid MS, Craciunas L, Singh KK, Sains P, Baig MK. Open transinguinal preperitoneal mesh repair of inguinal hernia: a targeted systematic review and meta-analysis of published randomized controlled trials. Gastroenterol Rep (Oxf) 2013; 1:127-37. [PMID: 24759818 PMCID: PMC3938008 DOI: 10.1093/gastro/got002] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
OBJECTIVE The objective of this article is to systematically analyse the randomized, controlled trials comparing transinguinal preperitoneal (TIPP) and Lichtenstein repair (LR) for inguinal hernia. METHODS Randomized, controlled trials comparing TIPP vs LR were analysed systematically using RevMan® and combined outcomes were expressed as risk ratio (RR) and standardized mean difference. RESULTS Twelve randomized trials evaluating 1437 patients were retrieved from the electronic databases. There were 714 patients in the TIPP repair group and 723 patients in the LR group. There was significant heterogeneity among trials (P < 0.0001). Therefore, in the random effects model, TIPP repair was associated with a reduced risk of developing chronic groin pain (RR, 0.48; 95% CI, 0.26, 0.89; z = 2.33; P < 0.02) without influencing the incidence of inguinal hernia recurrence (RR, 0.18; 95% CI, 0.36, 1.83; z = 0.51; P = 0.61). Risk of developing postoperative complications and moderate-to-severe postoperative pain was similar following TIPP repair and LR. In addition, duration of operation was statistically similar in both groups. CONCLUSION TIPP repair for inguinal hernia is associated with lower risk of developing chronic groin pain. It is comparable with LR in terms of risk of hernia recurrence, postoperative complications, duration of operation and intensity of postoperative pain.
Collapse
Affiliation(s)
- Muhammad S Sajid
- Department of General & Laparoscopic Colorectal Surgery, Worthing Hospital, Worthing. West Sussex. BN11 2DH. UK
| | | | | | | | | |
Collapse
|
15
|
Kaul A, Hutfless S, Le H, Hamed SA, Tymitz K, Nguyen H, Marohn MR. Staple versus fibrin glue fixation in laparoscopic total extraperitoneal repair of inguinal hernia: a systematic review and meta-analysis. Surg Endosc 2012; 26:1269-78. [PMID: 22350225 DOI: 10.1007/s00464-011-2025-2] [Citation(s) in RCA: 92] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2011] [Accepted: 06/22/2011] [Indexed: 01/27/2023]
Abstract
BACKGROUND Fixation of mesh is typically performed to minimize risk of recurrence in laparoscopic inguinal hernia repair. Mesh fixation with staples has been implicated as a cause of chronic inguinal pain. Our study aim is to compare mesh fixation using a fibrin sealant versus staple fixation in laparoscopic inguinal hernia and compare outcomes for hernia recurrence and chronic inguinal pain. METHODS AND PROCEDURES PubMed was searched through December 2010 by use of specific search terms. Inclusion criteria were laparoscopic total extraperitoneal repair inguinal hernia repair, and comparison of both mesh fibrin glue fixation and mesh staple fixation. Primary outcomes were inguinal hernia recurrence and chronic inguinal pain. Secondary outcomes were operative time, seroma formation, hospital stay, and time to return to normal activity. Pooled odds ratios (OR) were calculated assuming random-effects models. RESULTS Four studies were included in the review. A total of 662 repairs were included, of which 394 were mesh fixed by staples or tacks, versus 268 with mesh fixed by fibrin glue. There was no difference in inguinal hernia recurrence with fixation of mesh by staples/tacks versus fibrin glue [OR 2.13; 95% confidence interval (CI) 0.60-7.63]. Chronic inguinal pain (at 3 months) incidence was significantly higher with staple/tack fixation (OR 3.25; 95% CI 1.62-6.49). There was no significant difference in operative time, seroma formation, hospital stay, or time to return to normal activities. CONCLUSIONS The meta-analysis does not show an advantage of staple fixation of mesh over fibrin glue fixation in laparoscopic total extraperitoneal inguinal hernia repair. Because fibrin glue mesh fixation with laparoscopic inguinal hernia repair achieves similar hernia recurrence rates compared with staple/tack fixation, but decreased incidence of chronic inguinal pain, it may be the preferred technique.
Collapse
Affiliation(s)
- Amit Kaul
- Minimally Invasive Surgery Training & Innovation Center (MISTIC), Department of Surgery, Johns Hopkins University School of Medicine, MISTIC/Blalock 1222, 600 North Wolfe Street, Baltimore, MD 21287, USA
| | | | | | | | | | | | | |
Collapse
|
16
|
Sajid M, Ladwa N, Kalra L, Hutson K, Sains P, Baig M. A meta-analysis examining the use of tacker fixation versus no-fixation of mesh in laparoscopic inguinal hernia repair. Int J Surg 2012; 10:224-31. [DOI: 10.1016/j.ijsu.2012.03.001] [Citation(s) in RCA: 47] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2011] [Revised: 02/27/2012] [Accepted: 03/05/2012] [Indexed: 10/28/2022]
|
17
|
Perko Z, Rakić M, Pogorelić Z, Družijanić N, Kraljević J. Laparoscopic transabdominal preperitoneal approach for inguinal hernia repair: a five-year experience at a single center. Surg Today 2011; 41:216-21. [PMID: 21264757 DOI: 10.1007/s00595-010-4266-4] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2009] [Accepted: 01/17/2010] [Indexed: 10/18/2022]
Abstract
PURPOSE Laparoscopic hernia repair has emerged as an effective alternative method for treating inguinal hernias. It has several significant advantages over the tension-free open repair now in use. In this report we summarize our laparoscopic hernia repair results and recommendations. METHODS The transabdominal preperitoneal (TAPP) procedures for groin hernias performed between January 2003 and January 2008 at a single center were analyzed retrospectively. Individual surgeon performances were compared to determine whether the rates of complications were related to the level of surgeon experience. RESULTS A total of 312 TAPP procedures were reviewed, and 284 (91%) of the patients were followed retrospectively. There were 266 (85.25%) males and 46 (14.75%) females. The average age was 57.4 years. The mean length of hospital stay was 2.1 days. The mean duration of surgery was 35 min. Six (1.92%) intraoperative and seven (2.24%) postoperative complications were noted. Two recurrences occurred (0.70%). CONCLUSIONS Laparoscopic TAPP hernia repair has proven to be an efficient method for the treatment of groin hernias at our institution. Most patients can be treated as day-cases, namely they are hospitalized for 1 day, and they demonstrate a low recurrence rate (0.70%). Such low morbidity makes TAPP an attractive method for the routine treatment of groin hernias.
Collapse
Affiliation(s)
- Zdravko Perko
- Department of Surgery, University Hospital Split and Split University School of Medicine, Spinčićeva 1, Split, Croatia
| | | | | | | | | |
Collapse
|
18
|
Spray application of fibrin sealant with an angled spray tip device in laparoscopic inguinal hernia repair. Eur Surg 2010. [DOI: 10.1007/s10353-010-0550-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
19
|
Small bowel obstruction owing to displaced spiral tack after laparoscopic TAPP inguinal hernia repair. Surg Laparosc Endosc Percutan Tech 2010; 20:e132-5. [PMID: 20551794 DOI: 10.1097/sle.0b013e3181dfbc05] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Laparoscopic repair of inguinal hernias has become a widely accepted technique owing to its safety, efficacy, and patient satisfaction. Laparoscopic inguinal herniorrhaphies, such as the transabdominal preperitoneal (TAPP) and the totally extraperitoneal approaches, usually employ a method of fixation involving staples, titanium spiral tacks, or sutures to secure the mesh over the myopectineal orifice. The TAPP approach also requires closure of the peritoneal flap to exclude the mesh from the intraabdominal contents. Overall complication rates with TAPP are low, with small bowel obstruction incidence of 0.2% to 0.5%. This is usually attributed to inadequate peritoneal closure, trocar site herniation, or adhesions. We report a case of small bowel obstruction caused by a displaced spiral tack used for the peritoneal closure during TAPP hernia repair.
Collapse
|
20
|
Tam KW, Liang HH, Chai CY. Outcomes of Staple Fixation of Mesh Versus Nonfixation in Laparoscopic Total Extraperitoneal Inguinal Repair: A Meta-Analysis of Randomized Controlled Trials. World J Surg 2010; 34:3065-74. [DOI: 10.1007/s00268-010-0760-5] [Citation(s) in RCA: 52] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
21
|
Fortelny RH, Petter-Puchner AH, Ferguson J, Gruber-Blum S, Brand J, Mika K, Redl H. A comparative biomechanical evaluation of hernia mesh fixation by fibrin sealant. J Surg Res 2010; 171:576-81. [PMID: 20869077 DOI: 10.1016/j.jss.2010.06.001] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2010] [Revised: 05/18/2010] [Accepted: 06/01/2010] [Indexed: 11/19/2022]
Abstract
BACKGROUND The atraumatic fixation of meshes by fibrin sealant (FS) has been established for both open and laparoscopic techniques of hernia repair. This study was performed to evaluate the use of FS in hernia mesh fixation with different polymerization speed (thrombin concentrations), using commercial hernia meshes, and in two techniques, transabdominal preperitoneal mesh placement (TAPP) and intraperitoneal mesh placement (IPOM). MATERIALS AND METHODS A median laparotomy was performed in a pig model and hernia meshes were placed in IPOM and TAPP techniques. After mesh fixation with FS using thrombin concentrations of 4 and 500 IU/mL, maximum shear force before failure was measured at 5, 60, and 120 min. RESULTS At both thrombin concentrations and in all meshes in which the technique was used, the TAPP method tended to show higher maximum force levels at failure than did the IPOM method. In both TAPP and IPOM techniques and in all meshes, the 4 IU/mL thrombin concentration FS was superior to the 500 IU/mL thrombin concentration sealant. CONCLUSIONS Although both thrombin concentrations are suitable for mesh fixation, lower concentrations allow slower polymerization and better sealant diffusion leading to higher maximum force levels at failure. The TAPP method was biomechanically superior to the IPOM method. There were no major differences between mesh products.
Collapse
|
22
|
Ferzli GS, Edwards E, Al-Khoury G, Hardin R. Postherniorrhaphy groin pain and how to avoid it. Surg Clin North Am 2008; 88:203-16, x-xi. [PMID: 18267170 DOI: 10.1016/j.suc.2007.10.006] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
Abstract
Groin pain following inguinal hernia repair remains a challenge to most general surgeons. Prevention of groin pain may be the most effective solution to this management problem and necessitates careful anatomic dissection and precise knowledge of surgical anatomy of the groin as well as potential pitfalls of surgical intervention. When complications arise, a period of watchful waiting is warranted, but surgical intervention with triple neurectomy offers the most definitive resolution of symptoms. This article aims to provide a thorough review of pertinent anatomic landmarks for the proper identification of the nerves that, if injured, result in chronic groin pain and to provide a treatment algorithm for patients suffering with this morbidity.
Collapse
Affiliation(s)
- George S Ferzli
- Department of Surgery, Lutheran Medical Center, 150 East 55th Street, Brooklyn, NY 11201, USA.
| | | | | | | |
Collapse
|
23
|
Golash V. Large gut fistula due to a protruding spiral tacker after laparoscopic repair of a ventral hernia. Oman Med J 2008; 23:50-52. [PMID: 22567213 PMCID: PMC3338997] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2007] [Accepted: 04/21/2008] [Indexed: 05/31/2023] Open
Abstract
Tackers (mesh fixation devices) are often used for securing the mesh in the laparoscopic repair of ventral, inguinal and hiatus hernia. By and large, their use is safe but occasionally the tackers are the cause of postoperative complications. Small gut perforations have been reported previously. We report here a case of large gut fistula secondary to an injury by a protruding tacker in the abdominal cavity presenting twenty days after the laparoscopic repair of a ventral hernia.
Collapse
Affiliation(s)
- Vishwanath Golash
- Address correspondence and reprint requests to: Dr. Vishwanath Golash, Sultan Qaboos Hospital, P.O.Box: 98, P.C. 211, Salalah, Sultanate of Oman.
| |
Collapse
|
24
|
Small bowel obstruction and perforation due to a displaced spiral tacker: a rare complication of laparoscopic inguinal hernia repair. Hernia 2007; 12:303-5. [PMID: 18026897 DOI: 10.1007/s10029-007-0289-1] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2007] [Accepted: 09/25/2007] [Indexed: 01/18/2023]
Abstract
Laparoscopic techniques are now commonly used for the repair of inguinal hernias, since they offer rapid postoperative recovery and low complication rates. These methods usually involve the use of sutures, staples or titanium spiral tackers for safe, secure mesh fixation. We report a rare case of obstruction and perforation of the small bowel resulting from a band adhesion caused by a displaced spiral tacker.
Collapse
|
25
|
Ndiaye A, Diop M, Ndoye JM, Konaté I, Ndiaye AI, Mané L, Nazarian S, Dia A. Anatomical basis of neuropathies and damage to the ilioinguinal nerve during repairs of groin hernias. (about 100 dissections). Surg Radiol Anat 2007; 29:675-81. [PMID: 17985072 DOI: 10.1007/s00276-007-0272-7] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2006] [Accepted: 07/07/2007] [Indexed: 01/28/2023]
Abstract
Surgical access to the inguinal region, notably during hernia repairs, exposes the ilioinguinal nerve to the risk of damage at the origin of the neuralgia. The incidence of these post-operative neuropathies and their medicolegal consequences justify this study about the anatomical variations of the ilioinguinal nerve. With the aim of preventing its damage during repairs of groin hernias and identifying the factors of onset of chronic spontaneous neuropathy of the ilioinguinal nerve, we dissected 100 inguinal regions of 51 fresh adult corpses. The nerve was absent in seven cases and double in one case. Out of the 94 ilioinguinal nerves observed, we analyzed the path in relation to the inguinal ligament and the connections with the walls of the inguinal canal and its content. The ilioinguinal nerve travels along the superficial surface of the internal oblique muscle, passing on average 1.015 cm from the inguinal ligament. In one case, the fibers of the internal oblique muscle spanned it in several places. The nerve was antero-funicular in 78.72% of cases and perforated the fascia of the external oblique in 28.72% of cases. The terminal division took place in the inguinal canal in 86% of cases, with terminal branches that sometimes perforated the fascia of the external oblique. These results enabled us to better understand the etiopathogenic aspects of certain neuropathies of the groin and to propose techniques useful for the protection of the nerve during repairs of groin hernias.
Collapse
Affiliation(s)
- A Ndiaye
- Laboratoire d'Anatomie et d'Organogénèse, Faculté de Médecine, de Pharmacie et d'Odontologie, Université Cheikh Anta Diop, BP: 5419, Dakar-Fann, Sénégal.
| | | | | | | | | | | | | | | |
Collapse
|
26
|
Ferzli GS, Edwards ED, Khoury GE. Chronic pain after inguinal herniorrhaphy. J Am Coll Surg 2007; 205:333-41. [PMID: 17660082 DOI: 10.1016/j.jamcollsurg.2007.02.081] [Citation(s) in RCA: 59] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2006] [Revised: 02/21/2007] [Accepted: 02/21/2007] [Indexed: 12/14/2022]
Affiliation(s)
- George S Ferzli
- Department of Surgery, Lutheran Medical Center, Brooklyn, NY, USA
| | | | | |
Collapse
|
27
|
Berthelot JM. Syndromes canalaires des nerfs ilio-hypogastriques, ilio-inguinaux, génitofémoraux, obturateurs et pudendal. ACTA ACUST UNITED AC 2007. [DOI: 10.1016/j.rhum.2007.01.004] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
|
28
|
Whiteside JL, Barber MD, Walters MD, Falcone T. Anatomy of ilioinguinal and iliohypogastric nerves in relation to trocar placement and low transverse incisions. Am J Obstet Gynecol 2003; 189:1574-8; discussion 1578. [PMID: 14710069 DOI: 10.1016/s0002-9378(03)00934-7] [Citation(s) in RCA: 74] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
OBJECTIVE The purpose of this study was to map the course of the ilioinguinal and iliohypogastric nerves. STUDY DESIGN The courses of iliohypogastric and ilioinguinal nerves from 11 fresh frozen cadavers were mapped from their lateral emergence on the anterior abdominal wall to their midline termination in reference to fixed bony landmarks. Bivariate fit ellipses were generated for each nerve and compared with sites of standard abdominal surgical incisions. RESULTS Thirteen iliohypogastric and 16 ilioinguinal nerves were identified and mapped. On average, the proximal end of the ilioinguinal nerve entered the abdominal wall 3.1 cm medial and 3.7 cm inferior to the anterior superior iliac spine, then followed a linear course to terminate 2.7 cm lateral to the midline and 1.7 cm superior to pubic symphysis. The iliohypogastric nerve entered the abdominal wall on average 2.1 cm medial and 0.9 cm inferior to the anterior superior iliac spine, which followed a linear course to terminate 3.7 cm lateral to the midline and 5.2 cm superior to pubic symphysis. CONCLUSION Abdominal wall surgical sites below the level of the anterior superior iliac spine have the potential for ilioinguinal or iliohypogastric injury.
Collapse
Affiliation(s)
- James L Whiteside
- Department of Gynecology and Obstetrics/A81, Cleveland Clinic Foundation, 9500 Euclid Avenue, Cleveland, OH 44195, USA.
| | | | | | | |
Collapse
|
29
|
Sandford R, Nicholson ML. Genito-femoral nerve entrapment: a complication of stapling the ureter during laparoscopic live donor nephrectomy. Nephrol Dial Transplant 2001; 16:2090-1. [PMID: 11572904 DOI: 10.1093/ndt/16.10.2090] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Affiliation(s)
- R Sandford
- Department of Surgery, Leicester General Hospital, UK
| | | |
Collapse
|
30
|
|