Calce L, Hafeez M, Hou W, Romanos GE. Thermal Effects of 445-nm Diode Laser Irradiation on Titanium and Ceramic Implants. J ORAL IMPLANTOL 2023; 49:401-406. [PMID: 37527174 DOI: 10.1563/aaid-joi-d-22-00234] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2022] [Revised: 02/13/2023] [Accepted: 06/01/2023] [Indexed: 08/03/2023]
Abstract
This study aimed to evaluate temperature changes in titanium and ceramic implants after using a 445-nm diode laser under different in vitro conditions. Titanium (Ti) and ceramic (Zr) dental implants were placed into a bone analog, and an intrabony defect was created at each implant. A 445-nm diode laser was used to irradiate the defects for 30 seconds, noncontact, at 2 W in continuous wave (c.w.) and pulsed mode. The experiment was done at room temperature (21.0 ± 1°C) and in a water bath (37.0 ± 1°C). Two thermocouple probes were used to record real-time temperature changes (°C) at the coronal part of the implant (Tc) and the apex (Ta). The temperature was recorded at time 0 (To) and after 30 seconds of irradiation (Tf). The average temperature change was calculated, and a descriptive analysis was conducted (P < .05). The Ti implant resulted in the highest ΔT values coronally (29.6°C) and apically (6.7°C) using continuous wave at 21°C. The Zr implant increased to 26.4°C coronally and 5.2°C apically. In the water bath, the coronal portion of the Ti and Zr implants rose to 14.2°C and 14.01°C, respectively, using continuous waves. The ΔT values for Ti were 11.9°C coronally and 1.7°C apically when placed in a water bath using pulsed mode. The lowest ΔT occurred on the Zr implant with ΔTc and ΔTa of 4.8°C and 0.78°C, respectively. Under in vitro conditions, the 445-nm diode laser in pulsed mode seems to be safe for use on ceramic implants and should be used with caution on titanium implants.
Collapse
Affiliation(s)
- Loredana Calce
- Department of Periodontology, Laboratory for Periodontal-, Implant-, and Phototherapy, School of Dental Medicine, Stony Brook University, Stony Brook, New York
| | - Maryam Hafeez
- Department of Periodontology, Laboratory for Periodontal-, Implant-, and Phototherapy, School of Dental Medicine, Stony Brook University, Stony Brook, New York
| | - Wei Hou
- Department of Family, Population and Preventive Medicine, School of Medicine, Stony Brook, New York
| | - Georgios E Romanos
- Department of Periodontology, Laboratory for Periodontal-, Implant-, and Phototherapy, School of Dental Medicine, Stony Brook University, Stony Brook, New York
| |
Collapse
|
2
|
Mousa MM, Al-Jannan HMG, Sultan K, Ajaj MA, Hajeer MY, Al-Manadili A, Ammar AM, Awawdeh M. Effectiveness of Two Intensity Levels of Diode Laser in Debonding Metallic Brackets Regarding Enamel Surface Integrity and Pulpal Temperature: An Ex-Vivo Study. Cureus 2023; 15:e41372. [PMID: 37408936 PMCID: PMC10319451 DOI: 10.7759/cureus.41372] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/04/2023] [Indexed: 07/07/2023] Open
Abstract
INTRODUCTION The traditional methods of deboning metal brackets exert excessive force, resulting in enamel scratches, fractures, and patient discomfort. The objective of this study was to evaluate the effectiveness of using two intensity levels of a diode laser for debonding metallic orthodontic brackets as an alternative to the conventional debonding method. MATERIALS AND METHODS Sixty intact, extracted human premolar teeth were used in this study, and metal orthodontic brackets were bonded to the buccal surface of these teeth. The teeth were divided into three groups for the experiment: (1) the control group, where conventional bracket debonding was performed using a debonding plier, (2) the first experimental group, where a diode laser (2.5W, 980nm) was utilized for laser debonding, and (3) the second experimental group, where a diode laser (5W, 980nm) was used for laser debonding. The laser was applied using a sweeping movement for 5 seconds. After debonding, the adhesive remnant index (ARI), the lengths, and the frequency of enamel cracks were compared among the groups. Additionally, an increase in intra-pulpal temperature was measured. RESULTS In all groups, there were no instances of enamel fractures. Laser debonding resulted in a significant reduction in both the frequency and length of newly formed enamel cracks compared to the conventional debonding method. The laser debonding group exhibited increases in intra-pulpal temperature of 2.37°C and 3.60°C in the second and third groups, respectively. These temperature increases were significantly lower than the threshold of 5.5°C. There were no significant differences observed in the ARI scores among the groups. CONCLUSION With all debonding methods, an increase in the length and frequency of enamel cracks should be anticipated. However, laser-assisted debonding of metal brackets offers the advantage of reducing the risk of enamel damage while avoiding thermal damage to the pulp.
Collapse
Affiliation(s)
- Mudar Mohammad Mousa
- Department of Orthodontics, Faculty of Dentistry, University of Damascus, Damascus, SYR
| | - Hiba M G Al-Jannan
- Department of Orthodontics, Faculty of Dentistry, University of Damascus, Damascus, SYR
| | - Kinda Sultan
- Department of Orthodontics, Faculty of Dentistry, University of Damascus, Damascus, SYR
| | - Mowaffak A Ajaj
- Department of Orthodontics, Faculty of Dentistry, University of Damascus, Damascus, SYR
| | - Mohammad Y Hajeer
- Department of Orthodontics, Faculty of Dentistry, University of Damascus, Damascus, SYR
| | - Ahmad Al-Manadili
- Department of Oral Histopathology, Damascus University, Damascus, SYR
| | - Ali Mohsen Ammar
- Department of Orthodontics, Faculty of Dentistry, Arab Private University for Science and Technology, Hama, SYR
| | - Mohammed Awawdeh
- Department of Preventive Dental Science, College of Dentistry, King Saud Bin Abdulaziz University for Health Sciences, Riyadh, SAU
| |
Collapse
|
3
|
Fornaini C, Fekrazad R, Rocca JP, Zhang S, Merigo E. Use of Blue and Blue-Violet Lasers in Dentistry: A Narrative Review. J Lasers Med Sci 2021; 12:e31. [PMID: 34733754 DOI: 10.34172/jlms.2021.31] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2020] [Accepted: 12/06/2020] [Indexed: 01/19/2023]
Abstract
Introduction: Blue and blue-violet diode lasers (450 and 405 nm) seem to represent an interesting approach for several clinical treatments today. The aim of this narrative review is to describe and comment on the literature regarding the utilization of blue and blue-violet lasers in dentistry. Methods: A search for "blue laser AND dentistry" was conducted using the PubMed database, and all the papers referring to this topic, ranging from 1990 to April 2020, were analyzed in the review. All the original in vivo and in vitro studies using 450 nm or 405 nm lasers were included in this study. All the articles on the LED light, laser wavelengths other than 405 and 450 nm and using lasers in specialties other than dentistry, as well as case reports, guideline papers and reviews were excluded. Results: From a total of 519 results, 47 articles met the inclusion criteria and were divided into 8 groups based on their fields of application: disinfection (10), photobiomodulation (PBM) (4), bleaching (1), resin curing (20), surgery (7), periodontics (1), endodontics (1) and orthodontics (3). Conclusion: Blue and blue-violet diode lasers may represent new and effective devices to be used in a large number of applications in dentistry, even if further studies will be necessary to fully clarify the potentialities of these laser wavelengths.
Collapse
Affiliation(s)
- Carlo Fornaini
- Laboratoire MICORALIS (MICrobiologie ORALe, Immunothérapie et Santé) EA7354, Université Nice Sophia Antipolis, UFR Odontologie, Avenue des Diables Bleus, 06000 Nice, France.,Group of Applied Electro Magnetics (GAEM), Department of Engineering and Architecture, University of Parma, Viale G. P. Usberti 181/A -43124 -Parma, Italy.,2nd Hospital Shijiazhuang, Dept. of Stomatology, 53 Huaxi Road, Shijiazhuang 050051, China
| | - Reza Fekrazad
- Radiation Sciences Research Center, Laser Research Center in Medical Sciences, AJA University of Medical Sciences, Tehran, Iran.,International Network for Photo Medicine and Photo Dynamic Therapy (INPMPDT), Universal Scientific Education and Research Network (USERN), Tehran, Iran
| | - Jean-Paul Rocca
- Laboratoire MICORALIS (MICrobiologie ORALe, Immunothérapie et Santé) EA7354, Université Nice Sophia Antipolis, UFR Odontologie, Avenue des Diables Bleus, 06000 Nice, France.,2nd Hospital Shijiazhuang, Dept. of Stomatology, 53 Huaxi Road, Shijiazhuang 050051, China
| | - Shiying Zhang
- 2nd Hospital Shijiazhuang, Dept. of Stomatology, 53 Huaxi Road, Shijiazhuang 050051, China
| | - Elisabetta Merigo
- Laboratoire MICORALIS (MICrobiologie ORALe, Immunothérapie et Santé) EA7354, Université Nice Sophia Antipolis, UFR Odontologie, Avenue des Diables Bleus, 06000 Nice, France.,2nd Hospital Shijiazhuang, Dept. of Stomatology, 53 Huaxi Road, Shijiazhuang 050051, China
| |
Collapse
|
4
|
Panariello BHD, Cavichioli EAM, Sochacki SF, Gandini Junior LG, Duarte S. Blue light & chlorhexidine therapies on Streptococcus mutans biofilm and its regrowth on an in vitro orthodontic model. Am J Orthod Dentofacial Orthop 2021; 161:103-114. [PMID: 34452788 DOI: 10.1016/j.ajodo.2020.06.050] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2020] [Revised: 05/01/2020] [Accepted: 06/01/2020] [Indexed: 11/17/2022]
Abstract
INTRODUCTION Fixed orthodontic appliances create areas of stagnation for dental biofilms and make it difficult to clean the teeth; therefore, there is a risk of developing incipient caries lesions during the orthodontic treatment. The objective of this study is to determine if the combination of 2 different therapies, phototherapy by blue light (BL) and the antimicrobial 0.12% chlorhexidine (CHX) on enamel, orthodontic brackets, and elastics, would reduce or inhibit mature Streptococcus mutans biofilms and their regrowth on these substrates 24 hours after the application of the treatment; and if this treatment would interfere with bracket adhesion to the enamel. METHODS Biofilms of S. mutans UA159 were formed for 5-days over samples composed of a bovine enamel, orthodontic bracket, and orthodontic elastic. Then, the specimens were treated with 0.89% NaCl for 1 minute, BL for 12 minutes (72 J/cm2), 0.12% CHX for 1 minute, and BL for 12 minutes, followed by 0.12% CHX for 1 minute (BL+CHX). Biofilm was evaluated by colonies forming units and dry weight immediately after treatments and 24 hours after treatments (regrowth). The pH of the spent media was measured on the fifth and sixth days. Biofilm formation on the samples after the treatments and regrowth was visually evaluated by confocal laser scanning microscopy. Shear bond strength (SBS) between bracket and enamel was evaluated using a universal testing machine at a crosshead speed of 1 mm/min. After bonding, specimens were thermocycled (500× at 5-55°C), treated, and thermocycled again. RESULTS After 5 days of biofilm formation, BL+CHX significantly reduced the bacterial viability on enamel compared with NaCl (P = 0.004) and BL (P = 0.014). For bracket and elastic, all the treatments resulted in similar bacterial viability (P ≥0.081). In the regrowth, CHX and BL+CHX significantly reduced the bacterial viability in the enamel compared with the NaCl (P ≤0.015) and BL (P ≤0.013). For bracket, BL+CHX significantly reduced the bacterial viability compared with NaCl (P = 0.008) and BL (P = 0.009). For the elastic, BL+CHX eliminated the biofilms from the substrate. CHX and BL+CHX significantly reduced the bacterial viability 24 hours after treatment for all substrates (P ≤0.05). The media pH significantly increased when samples were treated with CHX and BL+CHX (P ≤0.001). Confocal laser scanning microscopy images visually showed an abundant quantity of red cells in the samples treated with BL+CHX. There was no difference in the SBS between the treatments (P ≥0.932). CONCLUSIONS The association between BL and CHX reduced S. mutans biofilm and its regrowth on an in vitro orthodontic model and did not influence the bonding strength between bracket and enamel.
Collapse
Affiliation(s)
- Beatriz H D Panariello
- Department of Cariology, Operative Dentistry and Dental Public Health, Indiana University School of Dentistry, Indianapolis, Ind
| | - Eder A M Cavichioli
- Department of Orthodontics and Pediatric Dentistry, School of Dentistry at Araraquara, UNESP São Paulo State University, Araraquara, São Paulo, Brazil
| | - Sabrina Feitosa Sochacki
- Department of Biomedical Sciences and Comprehensive Care, Indiana University School of Dentistry, Indianapolis, Ind
| | - Luiz Gonzaga Gandini Junior
- Department of Orthodontics and Pediatric Dentistry, School of Dentistry at Araraquara, UNESP São Paulo State University, Araraquara, São Paulo, Brazil
| | - Simone Duarte
- Department of Cariology, Operative Dentistry and Dental Public Health, Indiana University School of Dentistry, Indianapolis, Ind.
| |
Collapse
|
5
|
Knaup T, Korbmacher-Steiner H, Braun A, Wenzler JS, Knaup I, Stein S. Effects of 445-nm Diode Laser-Assisted Debonding of Metallic Brackets on Shear Bond Strength and Enamel Surface Morphology. PHOTOBIOMODULATION PHOTOMEDICINE AND LASER SURGERY 2020; 38:160-166. [PMID: 32195639 DOI: 10.1089/photob.2019.4704] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
Objective: To evaluate the effect of a 445-nm diode laser on the shear bond strength (SBS) of metallic brackets before debonding. Background: Due to the new blue laser technology, very few studies are available in this context. Methods: Seventy metallic brackets (Discovery; Dentaurum, Ispringen, Germany) were bonded to the frontal enamel surfaces of 70 caries-free bovine incisors in a standardized way. Each sample was randomly assigned to the control or laser group, with 35 samples per group. The brackets in the laser group were irradiated with the diode laser (SIROLaser Blue®; Sirona, Bensheim, Germany) on three sides of the bracket bases for 5 s each (lateral-coronal-lateral, a total of 15 s) immediately before debonding. SBS values were evaluated for the control group and laser group. Micrographs of the enamel surface were taken with 10 × magnification to assess the adhesive remnant index (ARI) and the degree of enamel fractures after debonding. Results: There were no statistically significant differences in SBS in the laser group in comparison with the control group (p > 0.05). The distribution of ARI scores was also not statistically significantly different in the laser group in comparison with the control group (p > 0.05). Three enamel fractures occurred in the control group and one in the laser group after debonding. Conclusions: Irradiation of metallic brackets with the 445-nm diode laser before debonding does not significantly reduce the SBS values and does not influence the remaining amount of adhesive on the enamel surface. The risk of enamel fractures during debonding is therefore not clinically affected.
Collapse
Affiliation(s)
- Thomas Knaup
- Department of Orthodontics, University of Marburg, Marburg, Germany
| | | | - Andreas Braun
- Clinic of Operative Dentistry, Periodontology and Preventive Dentistry, University of Aachen, Aachen, Germany
| | - Johannes-Simon Wenzler
- Clinic of Operative Dentistry, Periodontology and Preventive Dentistry, University of Aachen, Aachen, Germany
| | - Isabel Knaup
- Department of Orthodontics, University of Aachen, Aachen, Germany
| | - Steffen Stein
- Clinic of Operative Dentistry, Periodontology and Preventive Dentistry, University of Aachen, Aachen, Germany
| |
Collapse
|
6
|
Yassaei S, Aghili H, Ebrahimi-Nik Z. Different modes of diode laser irradiation: effects on enamel surface and intrapulpal temperature at debonding. Laser Ther 2018; 27:214-218. [PMID: 32158067 DOI: 10.5978/islsm.27_18-or-20] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Background laser aided debonding of ceramic brackets has been proved to be effective in reducing enamel surface damages, though the optimal parameters of laser to be chose is in question. The aim of this study was to investigate the six different regimens of diode laser irradiation on enamel surface characteristics and intrapulpal temperature changes while debonding. Materials and methods 90 polycrystalline brackets were bonded to 90 intact extracted premolars. At debonding, teeth were divided into 6 groups (n = 15) and were subjected to the following regimen of diode laser irradiation; G1 = 2 W, continuous wave, G2 = 2.5 W, continuous wave, G3 = 3 W, continuous wave, G4 = 2 W, pulsed mode, G5 = 2.5 W, pulsed mode, G6 = 3 W, pulsed mode. After debonding, the adhesive remnant index, the lengths and frequency of enamel cracks were compared among the groups. 5 teeth out of 15 were randomly selected from each group to assess the intrapulpal temperature changes. Results The number of enamel cracks increased significantly in all the specimens after debonding. Enamel crack length increased significantly in all the study groups except G3 and G6. The increase in intrapulpal temperature was significantly below the benchmark of 5.5 C for all the specimens. Significant difference was observed in adhesive remnant index scores among the groups and more than half of the teeth showed a score of 2. Conclusion Diode-laser irradiation in pulsed mode or continuous wave at given outputs (2, 2.5, 3 W) were not statistically different in regard to producing enamel surface damages or increasing intrapulpal temperature.
Collapse
Affiliation(s)
- Soghra Yassaei
- Department of Orthodontics, Faculty of Dentistry, Shahid Sadoughi University of Medical Sciences, Yazd, Iran
| | - Hosseinagha Aghili
- Department of Orthodontics, Faculty of Dentistry, Shahid Sadoughi University of Medical Sciences, Yazd, Iran
| | - Zahra Ebrahimi-Nik
- Dental Clinic of Emam Reza Hospital, Mashhad University of Medical Sciences, Mashhad, Iran
| |
Collapse
|
7
|
Stein S, Wenzler J, Hellak A, Schauseil M, Korbmacher-Steiner H, Braun A. Intrapulpal Temperature Increases Caused by 445-nm Diode Laser-Assisted Debonding of Self-Ligating Ceramic Brackets During Simulated Pulpal Fluid Circulation. Photomed Laser Surg 2018; 36:185-190. [PMID: 29298403 DOI: 10.1089/pho.2017.4356] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
OBJECTIVE This study investigated temperature increases in dental pulp resulting from laser-assisted debonding of ceramic brackets using a 445-nm diode laser. MATERIALS AND METHODS Eighteen ceramic brackets were bonded in standardized manner to 18 caries-free human third molars. Pulpal fluid circulation was simulated by pumping distilled water at 37°C through the pulp chamber. The brackets were irradiated with a 445-nm diode laser. Temperatures were measured using a thermal camera at points P1 (center of the pulp) and P2 (in the hard dental tissue) at the baseline (T0), at the start and end of laser application (T1 and T2), and the maximum during the sequence (Tmax). RESULTS Significant differences in the temperatures measured at P1 and P2 were observed among T0, T1, T2, and Tmax. Significant increases in temperature were noted at points P1 and P2, between T1 and T2, T1 and Tmax, and T2 and Tmax. The maximum P2 values were significantly higher than at P1. The maximum temperature increase measured in the pulp was 2.23°C, lower than the critical threshold of 5.5°C. CONCLUSIONS On the basis of the laser settings used, there is no risk to the vitality of dental pulp during laser-assisted debonding of ceramic brackets with a 445-nm diode laser.
Collapse
Affiliation(s)
- Steffen Stein
- 1 Department of Orthodontics, University of Marburg , Marburg, Germany
| | - Johannes Wenzler
- 2 Department of Operative Dentistry and Endodontology, University of Marburg , Marburg, Germany
| | - Andreas Hellak
- 1 Department of Orthodontics, University of Marburg , Marburg, Germany
| | - Michael Schauseil
- 1 Department of Orthodontics, University of Marburg , Marburg, Germany
| | | | - Andreas Braun
- 2 Department of Operative Dentistry and Endodontology, University of Marburg , Marburg, Germany
| |
Collapse
|