This review systematically examines the literature on the ability of the classical epidural test dose and other strategies to detect intravascular, intrathecal, or subdural epidural needle/catheter misplacement. For detection of simulated intravascular misplacements, a sensitivity (S) and a positive predictive value (PPV) > or =80 demonstrated by at least two randomized controlled trials coming from two different centers were determined for the following tests and patient populations: Nonpregnant adult patients = increase in systolic blood pressure (SBP) > or =15 mm Hg (S = 80-100 and 93-100; PPV = 80-100 and 83-100) or either an increase in SBP > or =15 mm Hg or an increase in heart rate > or =10 bpm after the injection of 10 (S = 100; PPV = 83-100) or 15 microg of epinephrine (S = 100; PPV = 83-100); pregnant patients = sedation, drowsiness, or dizziness within 5 min after the injection of 100 microg of fentanyl (S = 92-100; PPV = 91-95); and children = increase in SBP > or =15 mm Hg after the injection of 0.5 microg/kg of epinephrine (S = 81-100; PPV = 100). Conversely, more studies are required to determine the best strategies to detect intrathecal and subdural epidural needle/catheter misplacements in these three patient populations.
Collapse
Affiliation(s)
- Joanne Guay
- Department of Anesthesia, Maisonneuve-Rosemont Hospital, University of Montreal, Canada.
| |
Collapse
|
2
|
Haemodynamic response to a small intravenous bolus injection of epinephrine in cardiac surgical patients. Eur J Anaesthesiol 2003. [DOI: 10.1097/00003643-200304000-00005] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
3
|
Goel S, Bhardwaj N, Grover VK. Intrathecal fentanyl added to intrathecal bupivacaine for day case surgery: a randomized study. Eur J Anaesthesiol 2003; 20:294-7. [PMID: 12703834 DOI: 10.1017/s0265021503000462] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
BACKGROUND AND OBJECTIVE The implication of intrathecal lidocaine in neurological toxicity has made intrathecal bupivacaine the commonly used drug for local anaesthesia in ambulatory surgery. However, in high doses intrathecal bupivacaine may produce a high level of sensory and motor block, and arterial hypotension; discharge from hospital may be delayed. Intrathecal opioids added to low-dose local anaesthetics produce a synergistic effect without increasing the sympathetic block or delaying discharge. The aim of our study was to identify the minimum effective dose of intrathecal fentanyl that in combination with low-dose intrathecal bupivacaine would provide adequate surgical conditions without prolonging recovery. METHODS A prospective, single, blind, randomized study was conducted in 45 adult males scheduled for minor urological procedures using intrathecal anaesthesia on a day care basis. Patients were randomly assigned to one of three groups (n = 15 each). They received bupivacaine 0.17% 5 mg--with either fentanyl 7.5 microg (fenta-7.5), 10 microg (fenta-10) or 12.5 microg (fenta-12.5) intrathecally in a total volume of 3 mL. The quality of anaesthesia, haemodynamic stability, time to two-segment and S2 regression, time to micturition, and time to discharge were assessed. RESULTS The time to two-segment regression and S2 regression with fenta-12.5 was significantly longer than with fenta-7.5 and fenta-10 (P < 0.01). Fenta-7.5 had a significantly higher number of failed blocks (four patients) compared with fenta-12.5 (P < 0.05). The time out of bed, time to micturition and time to discharge were significantly longer with fenta-10 and fenta-12.5 compared with fenta-7.5, and also with fenta-12.5 compared with fenta-10 (P < 0.01). Haemodynamic stability did not differ for all the drug combinations. CONCLUSIONS Fentanyl 12.5 microg added to low-dose bupivacaine (5 mg) intrathecally provides better surgical anaesthesia and increased reliability of block than intrathecal fentanyl 7.5 or 10 microg. Haemodynamic stability was the same for all dose combinations used.
Collapse
Affiliation(s)
- S Goel
- Postgraduate Institute of Medical Education and Research, Department of Anaesthesia and Intensive Care, Chandigarh, India
| | | | | |
Collapse
|
4
|
Abstract
The aim of this Review is to introduce anaesthesiologists to the basic physical principles that are important for their work. A better understanding of the underlying processes during anaesthesia is required for greater safety and efficiency. Relevant physical quantities are presented along with the area of anaesthesiology where they are used. This approach provides better targeting to the needs of practising anaesthesiologists. This text has been a part of a specialist course in anaesthesiology at the University of Ljubljana for some years. Current results show that both the students and the specialist anaesthesiologists now show a better understanding of the underlying physical principles required for their work and are more successful in fulfilling the needs of their practical work.
Collapse
Affiliation(s)
- A Manohin
- Medical Center, Department for Anaesthesiology, Ljubljana, Slovenia.
| | | |
Collapse
|
5
|
Klockgether-Radke AP, Thudium A, Frerichs A, Kettler D, Hellige G. High-dose midazolam and the attenuation of the contractile response to vasoconstrictors in coronary artery segments. Eur J Anaesthesiol 2003; 20:289-93. [PMID: 12703833 DOI: 10.1017/s0265021503000450] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
BACKGROUND AND OBJECTIVE Benzodiazepines may cause hypotension and are reported to interfere with smooth vascular muscle activity. The aim was to elucidate the influence of three different benzodiazepines on the vascular reactivity of coronary arteries. METHODS Using the model of isolated vessels, we studied the impact of midazolam (0.15, 1.5, 15 microg mL(-1)), diazepam (0.1, 1.0, 10 microg mL(-1)) and flunitrazepam (0.01, 0.1, 1.0 microg mL(-1)) on the contractile responses to histamine (2 x 10(-5) mol L(-1)) and serotonin (3 x 10(-5) mol L(-1)) in isolated intact and denuded coronary arteries. RESULTS Midazolam significantly attenuated the contractile response when administered in high concentrations (15 microg mL(-1)). This effect was more pronounced in intact than in denuded preparations (histamine: -22.7 versus -7.3%, P = 0.0079; serotonin: -47.1 versus -15.9%, P < 0.0001). Diazepam and flunitrazepam exerted no significant effects on the vascular tone of coronary arteries. CONCLUSIONS Midazolam, but not diazepam or flunitrazepam, attenuates the contractile responses to vasoconstrictors in concentrations beyond those used in clinical practice. This effect is in part mediated by endothelial factors.
Collapse
Affiliation(s)
- A P Klockgether-Radke
- Georg-August University of Göttingen, Department of Anaesthesiological Research, Centre of Anaesthesiology, Emergency and Intensive Care Medicine, Göttingen, Germany.
| | | | | | | | | |
Collapse
|
6
|
Payne K, Moore EW, Elliott RA, Pollard BJ, McHugh GA. Anaesthesia for day case surgery: a survey of adult clinical practice in the UK. Eur J Anaesthesiol 2003; 20:311-24. [PMID: 12703837 DOI: 10.1017/s0265021503000498] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
BACKGROUND AND OBJECTIVE In October 2000, we conducted a national postal survey of consultant day case anaesthetists in the UK to explore the range and variation in the practice of anaesthetizing a patient for day case surgery (paediatrics, urology and orthopaedics). The survey was carried out as part of a larger study that comprised a major two-centre randomized controlled trial designed to investigate the costs and outcome of several anaesthetic techniques during day care surgery in paediatric and adult patients (cost-effectiveness study of anaesthesia in day case surgery). We report the findings of this national survey of adult urology and orthopaedic day case anaesthetic practice in the UK. METHODS The survey used a structured postal questionnaire and collected data on the duration of the surgical procedure; the use of premedication; the anaesthetic agents used for induction and maintenance; the fresh gas flows used for anaesthesia; the use of antiemetics; and the administration of local anaesthesia and analgesia. RESULTS The overall response rate for the survey was 74% (63% for urology, 67% for orthopaedics). The survey indicated the following practice in adult urology and adult orthopaedic day case surgery: 6 and 12% used premedication; propofol was the preferred induction agent (96 and 97%) and isoflurane the preferred maintenance agent (56 and 58%); 32 and 41% used prophylactic antiemetics; 86 and 93% used a laryngeal mask. CONCLUSIONS This survey identifies the variation in current clinical practice in adult day surgery anaesthesia in the UK and discusses this variation in the context of current published evidence.
Collapse
Affiliation(s)
- K Payne
- University of Manchester, School of Pharmacy & Pharmaceutical Sciences, Manchester, UK.
| | | | | | | | | |
Collapse
|
7
|
Dahn J, Waschke KF, Stuck BA, Hörmann K. Fluid shifts in anaphylaxis. Eur J Anaesthesiol 2003; 20:331. [PMID: 12703839 DOI: 10.1017/s0265021503210516] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
8
|
White S, Parry M, Henderson K. Anaesthesia for total hip replacement in a patient with Holt-Oram syndrome. Eur J Anaesthesiol 2003; 20:336-8. [PMID: 12703842 DOI: 10.1017/s0265021503240515] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
9
|
Fattorutto M, Pradier O, Jansens JL, Ickx B, Barvais L. Plateletpheresis the day before cardiac surgery and the impairment of platelet function. Eur J Anaesthesiol 2003; 20:338-40. [PMID: 12703843 DOI: 10.1017/s0265021503250511] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
10
|
Estebe JP, Le Corre P, Clément R, Du Plessis L, Chevanne F, Le Verge R, Ecoffey C. Effect of dexamethasone on motor brachial plexus block with bupivacaine and with bupivacaine-loaded microspheres in a sheep model. Eur J Anaesthesiol 2003; 20:305-10. [PMID: 12703836 DOI: 10.1017/s0265021503000486] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
BACKGROUND AND OBJECTIVE It has been suggested that dexamethasone potentiates the sensory block produced by bupivacaine when both drugs are loaded in microspheres. The aim of the study was to evaluate the effect of dexamethasone on the brachial plexus block obtained with plain bupivacaine and bupivacaine-loaded microspheres. METHODS Dexamethasone alone (Group 5) or added to plain bupivacaine (75 mg) with (Groups 3 and 4) and without pH correction (Group 2) was compared with plain bupivacaine (75 mg; Group 1). The effect of a small dose of dexamethasone (0.42 mg) was then evaluated on the brachial plexus block obtained with bupivacaine (750 mg) as bupivacaine-loaded microspheres (Group 6). Dexamethasone was added either in the suspending medium (Group 7) or incorporated with bupivacaine into microspheres (Group 8). The motor block was evaluated in a plexus brachial sheep model. RESULTS Dexamethasone alone did not produce any motor block. When added to plain bupivacaine without pH correction, complete motor block could not be obtained. When the pH was corrected, addition of dexamethasone to plain bupivacaine seemed to delay the onset of motor block and did not prolong its duration, and it had no effect on the pharmacokinetics of bupivacaine. With bupivacaine-loaded microspheres, the duration of complete motor block was reduced when a small dose of dexamethasone was added in the suspending medium. However, the duration of motor block was significantly prolonged when dexamethasone was incorporated with bupivacaine into microspheres. CONCLUSIONS Despite the delayed onset of motor block, the incorporation of dexamethasone in bupivacaine-loaded microspheres dramatically increases the duration of action (700 +/- 485-5160 +/- 2136 min), which could be clinically relevant when such a drug-delivery system will be available.
Collapse
Affiliation(s)
- J P Estebe
- Université de Rennes 1, Service d'Anesthésie-Réanimation Chirurgicale 2, Hôpital Hôtel Dieu, Rennes, France.
| | | | | | | | | | | | | |
Collapse
|
11
|
Kaya M, Sariyildiz O, Karakus D, Ozalp G, Kadiogullari DN. Tramadol versus meperidine in the treatment of shivering during spinal anaesthesia. Eur J Anaesthesiol 2003; 20:332-3. [PMID: 12703840 DOI: 10.1017/s0265021503220512] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
12
|
Linton NWF, Linton RAF. Haemodynamic response to a small intravenous bolus injection of epinephrine in cardiac surgical patients. Eur J Anaesthesiol 2003; 20:298-304. [PMID: 12703835 DOI: 10.1017/s0265021503000474] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
BACKGROUND AND OBJECTIVE The aim was to study the rapid changes in cardiac output and systemic vascular resistance produced by intravenous epinephrine (5 microg) on a beat-by-beat basis. METHODS Ten patients were studied during cardiac surgery. Radial or brachial arterial pressure was recorded continuously during intravenous administration of epinephrine (5 microg). Cardiac output and systemic vascular resistance were derived for each beat using arterial pulse contour analysis calibrated by lithium indicator dilution. In each patient a further dose of epinephrine (5 microg) was administered during cardiopulmonary bypass with the blood flow kept constant so that changes in arterial pressure corresponded to changes in systemic vascular resistance. RESULTS When the patients were not on cardiopulmonary bypass, the epinephrine produced an initial increase in systemic vascular resistance to 129 +/- 15% (mean +/- SD) of control, followed by a more prolonged reduction to 57 +/- 13% of control. Cardiac output showed a small initial reduction coincident with the increase in systemic vascular resistance, followed by an increase to 152 +/- 24% of control. During cardiopulmonary bypass, the changes produced by epinephrine on systemic vascular resistance were qualitatively similar but smaller in amplitude, probably because of a greater volume of dilution in the bypass circuit. CONCLUSIONS Small bolus doses of epinephrine produce an initial increase in systemic vascular resistance followed by a much greater reduction that may cause hypotension.
Collapse
Affiliation(s)
- N W F Linton
- The Rayne Institute, St Thomas' Hospital, London, UK.
| | | |
Collapse
|
13
|
Payne K, Moore EW, Elliott RA, Moore JK, McHugh GA. Anaesthesia for day case surgery: a survey of paediatric clinical practice in the UK. Eur J Anaesthesiol 2003; 20:325-30. [PMID: 12703838 DOI: 10.1017/s0265021503000504] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
BACKGROUND AND OBJECTIVE In October 2000, we conducted a national postal survey of day case consultant anaesthetists in the UK to explore the range and variation in practice of anaesthetizing a patient for day case surgery (paediatrics, urology and orthopaedics). This paper reports the findings of this national survey of paediatric day case anaesthetic practice carried out as part of a major two-centre randomized controlled trial designed to investigate the costs and outcome of several anaesthetic techniques during day care surgery in paediatric and adult patients (cost-effectiveness study of anaesthesia in day case surgery). METHODS The survey used a structured postal questionnaire and collected data on the duration of surgical procedure; the use of premedication; the anaesthetic agents used for induction and maintenance; the fresh gas flow rates used for general anaesthesia; the use of antiemetics; and the administration of local anaesthesia and analgesia. RESULTS The overall response rate for the survey was 74 and 63% for the paediatric section of the survey. Respondents indicated that 19% used premedication, 63% used propofol for induction, 54% used isoflurane for maintenance, 24% used prophylactic antiemetics and 85%, used a laryngeal mask. The findings of this national survey are discussed and compared with published evidence. CONCLUSIONS This survey identifies the variation in clinical practice in paediatric day surgery anaesthesia in the UK.
Collapse
Affiliation(s)
- K Payne
- University of Manchester, School of Pharmacy & Pharmaceutical Sciences, Manchester, UK.
| | | | | | | | | |
Collapse
|
14
|
Weber TP, Van Aken H, Kehrel BE, Meissner A, Brüssel T, Bullmann V, Winkelmann W, Heindel W, Rolf N. Epidural bleed and quadriplegia due to acquired platelet dysfunction unrelated to multiple spinal and epidural puncture. Eur J Anaesthesiol 2003; 20:333-6. [PMID: 12703841 DOI: 10.1017/s0265021503230519] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
15
|
Hellwagner K, Holzer A, Gustorff B, Schroegendorfer K, Greher M, Weindlmayr-Goettel M, Saletu B, Lackner FX. Recollection of dreams after short general anaesthesia: influence on patient anxiety and satisfaction. Eur J Anaesthesiol 2003; 20:282-8. [PMID: 12703832 DOI: 10.1017/s0265021503000449] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
BACKGROUND AND OBJECTIVE We ascertained whether dreams during short general anaesthesia influence subsequent patient satisfaction and anxiety. METHODS Fifty female patients were randomized into two groups to test for a difference between intravenous and inhalational anaesthesias. In Group Propo, anaesthesia was induced and maintained with propofol; in Group Metho-Iso, anaesthesia was induced with methohexital and maintained with isoflurane. Satisfaction and anxiety with anaesthesia were evaluated using a visual analogue scale from 0 to 100. Dream incidence rate, satisfaction and anxiety were assessed from immediately after waking until 3 months later. RESULTS Seventeen patients (34%) dreamed during anaesthesia. There were no significant differences in satisfaction or anxiety after anaesthesia between the dreaming and non-dreaming patients (satisfaction, 92.3 +/- 21.6 versus 92.1 +/- 21.6; anxiety, 21.1 +/- 21.1 versus 30.3 +/- 32.1), or between Group Propo and Group Metho-Iso (satisfaction, 94.4 +/- 19.3 versus 90.0 +/- 23.4; anxiety, 26.0 +/- 27.6 versus 28.4 +/- 30.7). There was no significant difference in the incidence rate of dreaming with the type of anaesthesia used (Group Propo, 11 patients; Group Metho-Iso, 6 patients). CONCLUSIONS Dreaming during general anaesthesia is common but does not influence satisfaction or anxiety after anaesthesia.
Collapse
Affiliation(s)
- K Hellwagner
- University of Vienna, Department of Anaesthesia and General Intensive Care (A & B), Vienna, Austria.
| | | | | | | | | | | | | | | |
Collapse
|
16
|
Fisher QA, Shaffner DH, Yaster M. Detection of intravascular injection of regional anaesthetics in children. Can J Anaesth 1997; 44:592-8. [PMID: 9187777 DOI: 10.1007/bf03015441] [Citation(s) in RCA: 88] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023] Open
Abstract
PURPOSE Detection of intravascular injection of local anaesthetic during placement of regional blocks in children by using epinephrine-induced tachycardia or hypertension may produce false positive and false negative findings. This study evaluates ECG changes as markers of intravascular injection of local anaesthetics with epinephrine, during placement of epidural blocks in children. METHODS Observational study in a teaching hospital of all epidural anaesthetics administered to paediatric patients during one year. General anaesthesia, where used, was not controlled. An ECG rhythm strip was recorded during test dose injection and analyzed for changes in rate, rhythm, and T-wave configuration. RESULTS During the study period, 742 paediatric epidural blocks were administered. There were 644 caudal (284 without catheters), 97 lumbar, and one thoracic epidural anaesthetics. Satisfactory placement was achieved in 97.7% of patients. Intravascular injection was detected in 42 (5.6%) of epidural anaesthetics (3.8% and 6.7% of straight needle and catheter injections, respectively). Detection was by immediate aspiration of blood in six patients, and by heart rate increases > 10 bpm in 30. Five had heart rate decreases suggesting a baroreceptor response. Five had heart rate increases < 10 bpm that were possible responses to noxious stimuli. Of 30 patients with known intravascular injection and for whom ECG strips were available, 25 (83%) had T-wave amplitude increases > 25%, and 29 (97%) had ECG changes in T-wave or rhythm in response to the epinephrine injection. There were no false positives. CONCLUSION In order to reduce risks associated with epidural anaesthesia in children, epinephrine should be added to the local anaesthetic test dose, the ECG should be monitored continuously for changes in heart rate, rhythm, and T-wave amplitude. Epidural injections should be given in small increments.
Collapse
Affiliation(s)
- Q A Fisher
- Department of Anaesthesiology and Critical Care Medicine, Johns Hopkins University, Baltimore, MD 21287-5842, USA
| | | | | |
Collapse
|
17
|
Baylot D, Mahul P, Navez ML, Hajjar J, Prades JM, Auboyer C. [Cervical epidural anesthesia]. ANNALES FRANCAISES D'ANESTHESIE ET DE REANIMATION 1993; 12:483-92. [PMID: 8311355 DOI: 10.1016/s0750-7658(05)80996-7] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
Cervical epidural anaesthesia (CEA) results in an effective sensory blockade of the superficial cervical (C1/C4) and brachial plexus (C5/T1-T2). It is used both intraoperatively and in the treatment of postoperative or chronic pain. The approach to the epidural space at the C7-T1 interspace is not technically difficult. Patients are placed in the sitting position, increasing the negative pressure in the epidural space, with the head flexed on the thorax, in order to open the lowest cervical interspace. A 18-gauge Tuohy needle is inserted by a midline approach into the C6-C7 or C7-T1 interspace. A catheter may be inserted and left in place for postoperative analgesia. Local anaesthetics are administered either alone, or in combination with opiates. The CEA blocks the cardiac sympathetic fibers and consequently decreases heart rate, cardiac output and contractility. The mean blood pressure is unchanged or decreased, depending on peripheral systemic vascular resistance changes. The baroreflex activity is also partly impaired. Sympathetic blockade also decreases myocardial ischaemia. The cardiovascular changes induced by CEA are also partly due to the systemic effect of the local anaesthetic. The respiratory effects are minimal and depend on the extent of the blockade and the concentration of the local anaesthetic. A moderate restrictive syndrome occurs. Since the phrenic nerves originate from C3 to C5, ventilation may be impaired by CEA. Extension of the block may also impair intercostal muscle function, with a risk of respiratory failure when a CEA is used in patients with compromised respiratory function. The potential specific complications, mainly cardiovascular and respiratory, are the exacerbation of the effects of CEA. Side effects such as bradycardia, hypotension and acute ventilatory failure in relation to respiratory muscle paralysis, may be observed. Close monitoring of haemodynamics, respiratory rate and level blockade is required. Cervical epidural anaesthesia may be used either alone, or in combination with general anaesthesia depending on the surgical procedure. This technique seems to be effective in carotid artery surgery since sensitive and reliable information on cerebral function may be obtained. It is also for shoulder and upper limb surgery as well as for pharyngolaryngeal surgery, providing efficient operative anaesthesia and postoperative analgesia. CEA is used for relief of chronic pain in the head and neck or cancer pain due to Pancoast-Tobias syndrome. It seems to be effective for treating pain in patients with unstable angina pectoris or acute myocardial infarction.
Collapse
Affiliation(s)
- D Baylot
- Département d'Anesthésie-Réanimation, CHU, Hôpital Bellevue, Saint-Etienne
| | | | | | | | | | | |
Collapse
|
18
|
Gentili ME, Brassier J, Thomas AH. [Test dose and prevention of complications of epidural anesthesia]. ANNALES FRANCAISES D'ANESTHESIE ET DE REANIMATION 1993; 12:80-1. [PMID: 8338273 DOI: 10.1016/s0750-7658(05)80881-0] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
|