1
|
Vernemmen I, Van Steenkiste G, Hauspie S, De Lange L, Buschmann E, Schauvliege S, Van den Broeck W, Decloedt A, Vanderperren K, van Loon G. Development of a three-dimensional computer model of the equine heart using a polyurethane casting technique and in vivo contrast-enhanced computed tomography. J Vet Cardiol 2023; 51:72-85. [PMID: 38101318 DOI: 10.1016/j.jvc.2023.11.014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2022] [Revised: 11/13/2023] [Accepted: 11/16/2023] [Indexed: 12/17/2023]
Abstract
INTRODUCTION/OBJECTIVES Insight into the three-dimensional (3D) anatomy of the equine heart is essential in veterinary education and to develop minimally invasive intracardiac procedures. The aim was to create a 3D computer model simulating the in vivo anatomy of the adult equine heart. ANIMALS Ten horses and five ponies. MATERIALS AND METHODS Ten horses, euthanized for non-cardiovascular reasons, were used for in situ cardiac casting with polyurethane foam and subsequent computed tomography (CT) of the excised heart. In five anaesthetized ponies, a contrast-enhanced electrocardiogram-gated CT protocol was optimized to image the entire heart. Dedicated image processing software was used to create 3D models of all CT scans derived from both methods. Resulting models were compared regarding relative proportions, detail and ease of segmentation. RESULTS The casting protocol produced high detail, but compliant structures such as the pulmonary trunk were disproportionally expanded by the foam. Optimization of the contrast-enhanced CT protocol, especially adding a delayed phase for visualization of the cardiac veins, resulted in sufficiently detailed CT images to create an anatomically correct 3D model of the pony heart. Rescaling was needed to obtain a horse-sized model. CONCLUSIONS Three-dimensional computer models based on contrast-enhanced CT images appeared superior to those based on casted hearts to represent the in vivo situation and are preferred to obtain an anatomically correct heart model useful for education, client communication and research purposes. Scaling was, however, necessary to obtain an approximation of an adult horse heart as cardiac CT imaging is restricted by thoracic size.
Collapse
Affiliation(s)
- I Vernemmen
- Equine Cardioteam Ghent, Department of Internal Medicine, Reproduction and Population Medicine, Faculty of Veterinary Medicine, Ghent University, Salisburylaan 133, 9820 Merelbeke, Belgium.
| | - G Van Steenkiste
- Equine Cardioteam Ghent, Department of Internal Medicine, Reproduction and Population Medicine, Faculty of Veterinary Medicine, Ghent University, Salisburylaan 133, 9820 Merelbeke, Belgium
| | - S Hauspie
- Department of Morphology, Imaging, Orthopaedics, Rehabilitation and Nutrition, Faculty of Veterinary Medicine, Ghent University, Salisburylaan 133, 9820 Merelbeke, Belgium
| | - L De Lange
- Equine Cardioteam Ghent, Department of Internal Medicine, Reproduction and Population Medicine, Faculty of Veterinary Medicine, Ghent University, Salisburylaan 133, 9820 Merelbeke, Belgium
| | - E Buschmann
- Equine Cardioteam Ghent, Department of Internal Medicine, Reproduction and Population Medicine, Faculty of Veterinary Medicine, Ghent University, Salisburylaan 133, 9820 Merelbeke, Belgium
| | - S Schauvliege
- Department of Large Animal Surgery, Anaesthesia and Orthopaedics, Faculty of Veterinary Medicine, Ghent University, Salisburylaan 133, 9820 Merelbeke, Belgium
| | - W Van den Broeck
- Department of Morphology, Imaging, Orthopaedics, Rehabilitation and Nutrition, Faculty of Veterinary Medicine, Ghent University, Salisburylaan 133, 9820 Merelbeke, Belgium
| | - A Decloedt
- Equine Cardioteam Ghent, Department of Internal Medicine, Reproduction and Population Medicine, Faculty of Veterinary Medicine, Ghent University, Salisburylaan 133, 9820 Merelbeke, Belgium
| | - K Vanderperren
- Department of Morphology, Imaging, Orthopaedics, Rehabilitation and Nutrition, Faculty of Veterinary Medicine, Ghent University, Salisburylaan 133, 9820 Merelbeke, Belgium
| | - G van Loon
- Equine Cardioteam Ghent, Department of Internal Medicine, Reproduction and Population Medicine, Faculty of Veterinary Medicine, Ghent University, Salisburylaan 133, 9820 Merelbeke, Belgium
| |
Collapse
|
2
|
Kahl U, Vens M, Pollok F, Menke M, Duckstein C, Gruetzmacher J, Schirren L, Yu Y, Fischer M, Zöllner C, Goepfert MS, Roeher K. Do Elderly Patients With Diastolic Dysfunction Require Higher Doses of Norepinephrine During General Anesthesia for Noncardiac Surgeries? A Prospective Observational Study. Anesth Analg 2021; 132:420-429. [PMID: 33264119 DOI: 10.1213/ane.0000000000005304] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
BACKGROUND Diastolic dysfunction is a risk factor for postoperative major cardiovascular events. During anesthesia, patients with diastolic dysfunction might experience impaired hemodynamic function and worsening of diastolic function, which in turn, might be associated with a higher incidence of postoperative complications.We aimed to investigate whether patients with diastolic dysfunction require higher doses of norepinephrine during general anesthesia. Furthermore, we aimed to examine the association between the grade of diastolic dysfunction and the E/e' ratio during anesthesia. A high E/e' ratio corresponds to elevated filling pressures and is an important measure of impaired diastolic function. METHODS We conducted a prospective observational cohort study at a German university hospital from February 2017 to September 2018. Patients aged ≥60 years and undergoing general anesthesia (ie, propofol and sevoflurane) for elective noncardiac surgery were enrolled. Exclusion: mitral valve disease, atrial fibrillation, and implanted mechanical device.The primary outcome parameter was the administered dose of norepinephrine within 30 minutes after anesthesia induction (μg·kg-1 30 min-1). The secondary outcome parameter was the change of Doppler echocardiographic E/e' from ECHO1 (baseline) to ECHO2 (anesthesia). Linear models and linear mixed models were used for statistical evaluation. RESULTS A total of 247 patients were enrolled, and 200 patients (75 female) were included in the final analysis. Diastolic dysfunction at baseline was not associated with a higher dose of norepinephrine during anesthesia (P = .6953). The grade of diastolic dysfunction at baseline was associated with a decrease of the E/e' ratio during anesthesia (P < .001). CONCLUSIONS We did not find evidence for an association between diastolic dysfunction and impaired hemodynamic function, as expressed by high vasopressor support during anesthesia. Additionally, our findings suggest that diastolic function, as expressed by the E/e' ratio, does not worsen during anesthesia.
Collapse
Affiliation(s)
- Ursula Kahl
- From the Klinik und Poliklinik für Anästhesiologie
| | - Maren Vens
- Institut für Medizinische Biometrie und Epidemiologie, Universitätsklinikum Hamburg-Eppendorf, Hamburg, Germany.,Institut für Medizinische Biometrie und Statistik Universität zu Lübeck, Universitätsklinikum Schleswig-Holstein Campus Lübeck, Lübeck, Germany
| | | | - Maja Menke
- From the Klinik und Poliklinik für Anästhesiologie
| | | | | | | | - Yuanyuan Yu
- From the Klinik und Poliklinik für Anästhesiologie
| | | | | | - Matthias S Goepfert
- From the Klinik und Poliklinik für Anästhesiologie.,Klinik für Anästhesie und Intensivmedizin, Alexianer St. Hedwigkliniken Berlin, Berlin, Germany
| | | |
Collapse
|
3
|
Assessing Right Ventricular Function in the Perioperative Setting, Part I: Echo-Based Measurements. Anesthesiol Clin 2019; 37:675-695. [PMID: 31677685 DOI: 10.1016/j.anclin.2019.08.011] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
This article reviews transesophageal echocardiography-based assessment of perioperative right ventricular function and failure, including catheter-based methods, three-dimensional echocardiography, and their combination to make pressure-volume loops. It outlines right ventricular pathophysiology, multiple assessment methods, and their relationship to analogous transthoracic echocardiogram measurements. technologies used and developed for transthoracic or left ventricular assessment show significant limitations when applied to transesophageal assessment of the right ventricle. The article provides an overview of right ventricular assessment modalities that can be used in transesophageal echocardiography. Ultimately, clinicians must know limitations of measurements, synthesize information, and assess it in the clinical context.
Collapse
|
5
|
Kingwill AC, van der Westhuizen J, Turton EW. The effect of sevoflurane induction on the myocardial performance index in healthy individuals. SOUTHERN AFRICAN JOURNAL OF ANAESTHESIA AND ANALGESIA 2017. [DOI: 10.1080/22201181.2017.1402536] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Affiliation(s)
- Aidan C Kingwill
- Department of Anaesthesia, School of Medicine, University of the Free State, Bloemfontein, South Africa
| | | | - Edwin W Turton
- Department of Anaesthesia, School of Medicine, University of the Free State, Bloemfontein, South Africa
| |
Collapse
|