1
|
Schairer J, Römer J, Lang D, Neusüß C. CE-MS/MS and CE-timsTOF to separate and characterize intramolecular disulfide bridges of monoclonal antibody subunits and their application for the assessment of subunit reduction protocols. Anal Bioanal Chem 2024; 416:1599-1612. [PMID: 38296860 PMCID: PMC10899284 DOI: 10.1007/s00216-024-05161-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2023] [Revised: 01/15/2024] [Accepted: 01/17/2024] [Indexed: 02/02/2024]
Abstract
Characterization at the subunit level enables detailed mass spectrometric characterization of posttranslational modifications (PTMs) of monoclonal antibodies (mAbs). The implemented reduction often leaves the intramolecular disulfide bridges intact. Here, we present a capillary electrophoretic (CE) method based on a neutral-coated capillary for the separation of immunoglobulin G-degrading enzyme of Streptococcus pyogenes (IdeS) digested and reduced mAb subunits followed by mass spectrometry (MS), MS/MS identification, and trapped ion mobility mass spectrometry (timsTOF). Our CE approach enables the separation of (i) different subunit moieties, (ii) various reduction states, and (iii) positional isomers of these partly reduced subunit moieties. The location of the remaining disulfide bridges can be determined by middle-down electron transfer higher energy collisional dissociation (EThcD) experiments. All these CE-separated variants show differences in ion mobility in the timsTOF measurements. Applying the presented CE-MS/MS method, reduction parameters such as the use of chaotropic salts were studied. For the investigated antibodies, urea improved the subunit reduction significantly, whereas guanidine hydrochloride (GuHCl) leads to multiple signals of the same subunit in the CE separation. The presented CE-MS method is a powerful tool for the disulfide-variant characterization of mAbs on the subunit level. It enables understanding disulfide bridge reduction processes in antibodies and potentially other proteins.
Collapse
Affiliation(s)
- Jasmin Schairer
- Faculty of Chemistry, Aalen University, Aalen, Germany
- Faculty of Science, University of Tübingen, Tübingen, Germany
| | | | | | | |
Collapse
|
2
|
Nagy C, Andrasi M, Szabo R, Gaspar A. CZE-MS peptide mapping: To desalt or not to desalt? Anal Chim Acta 2024; 1288:342162. [PMID: 38220294 DOI: 10.1016/j.aca.2023.342162] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2023] [Revised: 12/10/2023] [Accepted: 12/16/2023] [Indexed: 01/16/2024]
Abstract
BACKGROUND In "shotgun" approaches involving high-performance liquid chromatography or capillary zone electrophoresis (CZE), matrix removal prior to sample analysis is considered as an indispensable tool. Despite the fact that CZE offers a high tolerance towards salts, most publications reported on the use of desalting. There seems to be no clear consensus on the utilization of desalting in the CZE-MS community, most probably due to the absence of works addressing the comparison of desalted and non-desalted digests. Our aim was to fill this research gap using protein samples of varying complexity in different sample matrices. RESULTS First, standard protein digests were analyzed to build the knowledge on the effect of sample clean-up by solid-phase extraction (SPE) pipette tips and the possible stacking phenomena induced by different sample matrices. Desalting led to a somewhat altered peptide profile, the procedure affected mostly the hydrophilic peptides (although not to a devastating extent). Nevertheless, desalting samples allowed remarkable stacking efficiency owing to their low-conductivity sample background, enabling a so-called field-amplified sample stacking phenomenon. Non-desalted samples also produced a stacking event, the mechanism of which is based on transient-isotachophoresis due to the presence of high-mobility ions in the digestion buffer itself. Adding either extra ammonium ions or acetonitrile into the non-desalted digests enhanced the stacking efficiency. A complex sample (yeast cell lysate) was also analyzed with the optimal conditions, which yielded similar tendencies. SIGNIFICANCE Based on these results, we propose that sample clean-up in the bottom-up sample preparation process prior to CZE-MS analysis can be omitted. The preclusion of desalting can even enhance detection sensitivity, separation efficiency or sequence coverage.
Collapse
Affiliation(s)
- Cynthia Nagy
- Department of Inorganic and Analytical Chemistry, University of Debrecen, Egyetem ter 1, Debrecen, 4032, Hungary
| | - Melinda Andrasi
- Department of Inorganic and Analytical Chemistry, University of Debrecen, Egyetem ter 1, Debrecen, 4032, Hungary
| | - Ruben Szabo
- Department of Inorganic and Analytical Chemistry, University of Debrecen, Egyetem ter 1, Debrecen, 4032, Hungary
| | - Attila Gaspar
- Department of Inorganic and Analytical Chemistry, University of Debrecen, Egyetem ter 1, Debrecen, 4032, Hungary.
| |
Collapse
|
3
|
Ostrowski MA, Mack S, Ninonuevo M, Yan J, ElNaggar M, Gentalen E, Michels DA. Rapid multi-attribute characterization of intact bispecific antibodies by a microfluidic chip-based integrated icIEF-MS technology. Electrophoresis 2023; 44:378-386. [PMID: 36200174 PMCID: PMC10092839 DOI: 10.1002/elps.202200165] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2022] [Revised: 09/26/2022] [Accepted: 09/28/2022] [Indexed: 02/09/2023]
Abstract
Rapid, direct identification and quantitation of protein charge variants, and assessment of critical quality attributes with high sensitivity are important drivers required to accelerate the development of biotherapeutics. We describe the use of an enhanced microfluidic chip-based integrated imaged capillary isoelectric focusing-mass spectrometry (icIEF-MS) technology to assess multiple quality attributes of intact antibodies in a single run. Results demonstrate comprehensive detection of multiple charge variants of an aglycosylated knob-into-hole bispecific antibody. Upfront, on-chip separation by icIEF coupled to MS provides the orthogonal separation required to resolve and identify acidic posttranslational modifications including difficult-to-detect deamidation and glycation events at the intact protein level. In addition, on-chip UV detection enables pI determination and relative quantitation of charge isoforms. Six charge variant peaks were resolved by icIEF, mobilized toward the on-chip electrospray tip and directly identified by in-line icIEF-MS using a connected quadrupole time-of-flight mass spectrometer. In addition to acidic charge variants, basic variants were identified as C-terminal lysine, N-terminal cyclization, proline amidation, and the combination of modifications (not typically identified by other intact methods), including lysine and one or two hexose additions. Nonspecific chain cleavages were also resolved, along with their acidic charge variants, demonstrating highly sensitive and comprehensive intact antibody multi-attribute characterization within a 15-min run time.
Collapse
|
4
|
He X, ElNaggar M, Ostrowski MA, Guttman A, Gentalen E, Sperry J. Evaluation of an icIEF-MS system for comparable charge variant analysis of biotherapeutics with rapid peak identification by mass spectrometry. Electrophoresis 2022; 43:1215-1222. [PMID: 35286725 PMCID: PMC9322286 DOI: 10.1002/elps.202100295] [Citation(s) in RCA: 15] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2021] [Revised: 02/02/2022] [Accepted: 02/04/2022] [Indexed: 01/27/2023]
Abstract
Protein therapeutics are usually produced in heterogeneous forms during bioproduction and bioprocessing. Heterogeneity results from post‐translational modifications that can yield charge variants and require characterization throughout product development and manufacturing. Isoelectric focusing (IEF) with UV detection is one of the most common methods to evaluate protein charge heterogeneity in the biopharmaceutical industry. To identify charge variant peaks, a new imaged microfluidic chip‐based isoelectric focusing (icIEF) system coupled directly to mass spectrometry was recently reported. Bridging is required to demonstrate comparability between existing and new technology. As such, here we demonstrate the comparability of the pI value measurement and relative charge species distributions between the icIEF‐MS system and the control data from a frequently utilized methodology in the biopharmaceutical industry for several blinded development‐phase biopharmaceutical monoclonal antibodies across a wide pI range of 7.3–9.0. Hyphenation of the icIEF system with mass spectrometry enabled direct and detailed structural determination of a test molecule, with masses suggesting acidic and basic shifts are caused by sialic acid additions and the presence of unprocessed lysine residues. In addition, MS analysis further identified several low‐abundance glycoforms. The icIEF‐MS system provides sample quantification, characterization, and identification of mAb proteoforms without sacrificing icIEF quantification comparability or speed.
Collapse
Affiliation(s)
| | | | | | - Andras Guttman
- Horvath Csaba Memorial Laboratory of Bioseparation Sciences, University of Debrecen, Hungary.,Previously with SCIEX
| | | | | |
Collapse
|
5
|
Hipper E, Blech M, Hinderberger D, Garidel P, Kaiser W. Photo-Oxidation of Therapeutic Protein Formulations: From Radical Formation to Analytical Techniques. Pharmaceutics 2021; 14:72. [PMID: 35056968 PMCID: PMC8779573 DOI: 10.3390/pharmaceutics14010072] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2021] [Revised: 12/09/2021] [Accepted: 12/14/2021] [Indexed: 12/25/2022] Open
Abstract
UV and ambient light-induced modifications and related degradation of therapeutic proteins are observed during manufacturing and storage. Therefore, to ensure product quality, protein formulations need to be analyzed with respect to photo-degradation processes and eventually protected from light exposure. This task usually demands the application and combination of various analytical methods. This review addresses analytical aspects of investigating photo-oxidation products and related mediators such as reactive oxygen species generated via UV and ambient light with well-established and novel techniques.
Collapse
Affiliation(s)
- Elena Hipper
- Institute of Chemistry, Martin-Luther-Universität Halle-Wittenberg, von-Danckelmann-Platz 4, 06120 Halle (Saale), Germany; (E.H.); (D.H.)
| | - Michaela Blech
- Boehringer Ingelheim Pharma GmbH & Co. KG, Innovation Unit, PDB, Birkendorfer Strasse 65, 88397 Biberach an der Riss, Germany;
| | - Dariush Hinderberger
- Institute of Chemistry, Martin-Luther-Universität Halle-Wittenberg, von-Danckelmann-Platz 4, 06120 Halle (Saale), Germany; (E.H.); (D.H.)
| | - Patrick Garidel
- Boehringer Ingelheim Pharma GmbH & Co. KG, Innovation Unit, PDB, Birkendorfer Strasse 65, 88397 Biberach an der Riss, Germany;
| | - Wolfgang Kaiser
- Boehringer Ingelheim Pharma GmbH & Co. KG, Innovation Unit, PDB, Birkendorfer Strasse 65, 88397 Biberach an der Riss, Germany;
| |
Collapse
|
6
|
Capillary electrophoresis and the biopharmaceutical industry: Therapeutic protein analysis and characterization. Trends Analyt Chem 2021. [DOI: 10.1016/j.trac.2021.116407] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
|
7
|
Kumar R, Guttman A, Rathore AS. Applications of capillary electrophoresis for biopharmaceutical product characterization. Electrophoresis 2021; 43:143-166. [PMID: 34591322 DOI: 10.1002/elps.202100182] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2021] [Revised: 09/07/2021] [Accepted: 09/23/2021] [Indexed: 12/16/2022]
Abstract
Capillary electrophoresis (CE), after being introduced several decades ago, has carved out a niche for itself in the field of analytical characterization of biopharmaceutical products. It does not only offer fast separation, high resolution in miniaturized format, but equally importantly represents an orthogonal separation mechanism to high-performance liquid chromatography. Therefore, it is not surprising that CE-based methods can be found in all major pharmacopoeias and are recommended for the analysis of biopharmaceutical products during process development, characterization, quality control, and release testing. Different separation formats of CE, such as capillary gel electrophoresis, capillary isoelectric focusing, and capillary zone electrophoresis are widely used for size and charge heterogeneity characterization as well as purity and stability testing of therapeutic proteins. Hyphenation of CE with MS is emerging as a promising bioanalytical tool to assess the primary structure of therapeutic proteins along with any impurities. In this review, we confer the latest developments in capillary electrophoresis, used for the characterization of critical quality attributes of biopharmaceutical products covering the past 6 years (2015-2021). Monoclonal antibodies, due to their significant share in the market, have been given prioritized coverage.
Collapse
Affiliation(s)
- Ramesh Kumar
- Department of Chemical Engineering, Indian Institute of Technology Delhi, Hauz Khas, New Delhi, India
| | - Andras Guttman
- Horváth Csaba Memorial Laboratories of Bioseparation Sciences, Research Center for Molecular Medicine, Faculty of Medicine, University of Debrecen, Debrecen, Hungary.,Translational Glycomics Group, Research Institute of Biomolecular and Chemical Engineering, University of Pannonia, Veszprem, Hungary
| | - Anurag S Rathore
- Department of Chemical Engineering, Indian Institute of Technology Delhi, Hauz Khas, New Delhi, India
| |
Collapse
|
8
|
Kaya SI, Cetinkaya A, Caglayan MG, Ozkan SA. Recent biopharmaceutical applications of capillary electrophoresis methods on recombinant DNA technology-based products. Electrophoresis 2021; 43:1035-1049. [PMID: 34529858 DOI: 10.1002/elps.202100193] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2021] [Revised: 08/17/2021] [Accepted: 09/05/2021] [Indexed: 11/11/2022]
Abstract
Biopharmaceuticals (recombinant technology-based products, vaccines, whole blood and blood components, gene therapy, cells, tissues, etc.,) are described as biological medical products produced from various living sources such as human, microbial, animal, and so on by manufacturing, extraction, or semi-synthesis. They are complex molecules having high molecular weights. For their safety and efficacy, their structural, clinical, physicochemical, and chemical features must be carefully controlled, and they must be well characterized by analytical techniques before the approval of the final product. Capillary electrophoresis (CE) having versatile modes can provide valuable safety and efficacy information, such as amino acid sequence, size variants (low and high molecular weight variants), charged variants (acidic and basic impurities), aggregates, N-linked glycosylation, and O-linked glycosylation. There are numerous applications of CE in the literature. In this review, the most significant and recent studies on the analysis of recombinant DNA technology-based products using different CE modes in the last ten years have been overviewed. It was seen that the researches mostly focus on the analysis of mAbs and IgG. In addition, in recent years, researchers have started to prefer CE combined mass spectrometry (MS) techniques to provide a more detailed characterization for protein and peptide fragments.
Collapse
Affiliation(s)
- S Irem Kaya
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara, Turkey.,Department of Analytical Chemistry, Gulhane Faculty of Pharmacy, University of Health Sciences, Ankara, Turkey
| | - Ahmet Cetinkaya
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara, Turkey
| | - Mehmet G Caglayan
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara, Turkey
| | - Sibel A Ozkan
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara, Turkey
| |
Collapse
|
9
|
Dykstra AB, Flick TG, Lee B, Blue LE, Angell N. Chip-Based Capillary Zone Electrophoresis Mass Spectrometry for Rapid Resolution and Quantitation of Critical Quality Attributes in Protein Biotherapeutics. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2021; 32:1952-1963. [PMID: 33730487 DOI: 10.1021/jasms.0c00424] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
The aspiration of the multi-attribute method (MAM) is to utilize a single mass spectrometry-based method that can measure multiple attributes simultaneously, thus enabling data-driven decisions more quickly and efficiently. However, challenges associated with identifying and quantitating critical quality attributes such as asparagine deamidation and isoaspartic acid using conventional ultrahigh-pressure liquid chromatography (UHPLC) coupled to mass spectrometry have necessitated long gradients to ensure sufficient separation for quantitation. Microfluidic chip-based capillary zone electrophoresis mass spectrometry (CZE-MS) shows potential to enable rapid charge-based separation of peptide mixtures, and this approach was evaluated using multipeptide mixtures of synthetic peptides as well as digested protein therapeutics. In these experiments, repeatability, linearity, and peak-to-peak resolution of several peptide families containing asparagine deamidation and/or isoaspartic acid were demonstrated. In addition, a comparison of peptide map results acquired with both UHPLC-MS and CZE-MS for two enzymatically digested biological therapeutics showed comparable sequence coverage and quantitation results between the two approaches. As MAM becomes increasingly utilized for analysis of biological therapeutics, MS instrument demand will rapidly increase, resulting in a bottleneck. A CZE-based separation shows potential to alleviate this bottleneck by drastically increasing MAM throughput while providing results comparable to those acquired using conventional UHPLC separations.
Collapse
Affiliation(s)
- Andrew B Dykstra
- Department of Attribute Sciences, Amgen, Inc., Thousand Oaks, California 91320, United States
| | - Tawnya G Flick
- Department of Attribute Sciences, Amgen, Inc., Thousand Oaks, California 91320, United States
| | - Burton Lee
- Department of Attribute Sciences, Amgen, Inc., Thousand Oaks, California 91320, United States
| | - Laura E Blue
- Department of Attribute Sciences, Amgen, Inc., Thousand Oaks, California 91320, United States
| | - Nic Angell
- Department of Attribute Sciences, Amgen, Inc., Thousand Oaks, California 91320, United States
| |
Collapse
|
10
|
Shen X, Liang Z, Xu T, Yang Z, Wang Q, Chen D, Pham L, Du W, Sun L. Investigating native capillary zone electrophoresis-mass spectrometry on a high-end quadrupole-time-of-flight mass spectrometer for the characterization of monoclonal antibodies. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY 2021; 462:116541. [PMID: 33642939 PMCID: PMC7906288 DOI: 10.1016/j.ijms.2021.116541] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/19/2023]
Abstract
Native capillary zone electrophoresis-mass spectrometry (CZE-MS) has attracted attentions for the characterization of monoclonal antibodies (mAbs) due to the potential of CZE for highly efficient separations of mAbs under native conditions as well as its compatibility with native electrospray ionization (ESI)-MS. However, the low sample loading capacity and limited separation resolution of native CZE for large proteins and protein complexes (e.g. mAbs) impede the widespread adoption of native CZE-MS. Here, we present a novel native capillary isoelectric focusing (cIEF)-assisted CZE-MS method for the characterization of mAbs with much larger sample loading capacity and significantly better separation resolution than native CZE-MS alone. The native cIEF-assisted CZE-MS employed separation capillaries with a new carbohydrate-based neutral coating, a commercilized electrokinetically pumped sheathflow CE-MS interface, and a high-end quadrupole-time-of-flight (Q-TOF) mass spectrometer. Using the method, we documented the separations of different proteoforms of the SigmaMAb and the detection of its various glyco-proteoforms and homodimer. The native cIEF-assisted CZE-MS separated the NIST mAb into three peaks with a submicroliter sample loading volume, corresponding to its different proteoforms. We observed that both the NIST mAb and its homodimer had eight glyco-proteoforms, four of which had low abundance. The results demonstrate the potential of our native cIEF-assisted CZE-MS method for advancing the characterization of large proteins and protein complexes under native conditions.
Collapse
Affiliation(s)
- Xiaojing Shen
- Department of Chemistry, Michigan State University, 578 S Shaw Ln, East Lansing, MI, USA 48824
| | - Zhijie Liang
- Department of Chemistry and Biochemistry, Central Michigan University, Mount Pleasant, MI, USA 48859
- Current address: Department of Wound Repair Surgery, The Fifth Affiliated Hospital of Guangxi Medical University & The First People’s Hospital of Nanning, Nanning, China 530000
| | - Tian Xu
- Department of Chemistry, Michigan State University, 578 S Shaw Ln, East Lansing, MI, USA 48824
| | - Zhichang Yang
- Department of Chemistry, Michigan State University, 578 S Shaw Ln, East Lansing, MI, USA 48824
| | - Qianjie Wang
- Department of Chemistry, Michigan State University, 578 S Shaw Ln, East Lansing, MI, USA 48824
| | - Daoyang Chen
- Department of Chemistry, Michigan State University, 578 S Shaw Ln, East Lansing, MI, USA 48824
| | - Lucynda Pham
- Department of Chemistry and Biochemistry, Central Michigan University, Mount Pleasant, MI, USA 48859
| | - Wenjun Du
- Department of Chemistry and Biochemistry, Central Michigan University, Mount Pleasant, MI, USA 48859
- Science of Advanced Materials, Central Michigan University, Mount Pleasant, MI, USA 48859
- Corresponding authors. Wenjun Du: ; Phone: 1-989-774-7568, Liangliang Sun: ; Phone: 1-517-353-0498
| | - Liangliang Sun
- Department of Chemistry, Michigan State University, 578 S Shaw Ln, East Lansing, MI, USA 48824
- Corresponding authors. Wenjun Du: ; Phone: 1-989-774-7568, Liangliang Sun: ; Phone: 1-517-353-0498
| |
Collapse
|
11
|
Dadouch M, Ladner Y, Bich C, Montels J, Morel J, Perrin C. Fast in-line bottom-up analysis of monoclonal antibodies: Toward an electrophoretic fingerprinting approach. Electrophoresis 2021; 42:1229-1237. [PMID: 33650106 DOI: 10.1002/elps.202000375] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2020] [Revised: 02/22/2021] [Accepted: 02/24/2021] [Indexed: 01/08/2023]
Abstract
For their characterization and quality control, monoclonal antibodies are frequently analyzed at the bottom-up level to generate specific fingerprints that can be used to tackle post-translational modifications or ensure production consistency between lots. To circumvent time-consuming and labor-intensive off-line sample preparation steps, the implementation of integrated methodologies from sample preparation to separation and detection is highly valuable. In this perspective, capillary zone electrophoresis appears as a choice technique since the capillary can subsequently be used as a vessel for sample preparation and electrophoretic discrimination/detection of the reaction products. Here, a fast in-line methodology for the routine quality control of mAbs at the bottom-up level is reported. Simultaneous denaturation and reduction (pretreatment step) were conducted with RapiGest® surfactant and dithiothreitol before in-line tryptic digestion. Reactant mixing was realized by transverse diffusion of laminar flow profile under controlled temperature. In-line digestion was carried out with a resistant trypsin to autolysis. The main parameters affecting the digestion efficiency (trypsin concentration and incubation conditions) were optimized to generate mAb electrophoretic profiles free from trypsin interferences. An acidic MS-compatible BGE was used to obtain high resolution separation of released peptides and in-line surfactant cleavage. The whole methodology was performed in less than two hours with good repeatability of migration times (RSD = 0.91%, n = 5) and corrected peak areas (RSD = 9.6%, n = 5). CE-fingerprints were successfully established for different mAbs and an antibody-drug conjugate.
Collapse
Affiliation(s)
- Meriem Dadouch
- UMR 5247-CNRS-UM-ENSCM, Institut des Biomolécules Max Mousseron (IBMM), Université de Montpellier, Montpellier, France
| | - Yoann Ladner
- UMR 5247-CNRS-UM-ENSCM, Institut des Biomolécules Max Mousseron (IBMM), Université de Montpellier, Montpellier, France
| | - Claudia Bich
- UMR 5247-CNRS-UM-ENSCM, Institut des Biomolécules Max Mousseron (IBMM), Université de Montpellier, Montpellier, France
| | - Jérôme Montels
- UMR 5247-CNRS-UM-ENSCM, Institut des Biomolécules Max Mousseron (IBMM), Université de Montpellier, Montpellier, France
| | - Jacques Morel
- Département de Rhumatologie, Université de Montpellier, Hôpital Lapeyronie, Montpellier Cedex 5, 34295, France
| | - Catherine Perrin
- UMR 5247-CNRS-UM-ENSCM, Institut des Biomolécules Max Mousseron (IBMM), Université de Montpellier, Montpellier, France
| |
Collapse
|
12
|
Hoang Anh N, Min JE, Kim SJ, Phuoc Long N. Biotherapeutic Products, Cellular Factories, and Multiomics Integration in Metabolic Engineering. ACTA ACUST UNITED AC 2020; 24:621-633. [DOI: 10.1089/omi.2020.0112] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Affiliation(s)
- Nguyen Hoang Anh
- College of Pharmacy, Seoul National University, Seoul, South Korea
| | - Jung Eun Min
- College of Pharmacy, Seoul National University, Seoul, South Korea
| | - Sun Jo Kim
- College of Pharmacy, Seoul National University, Seoul, South Korea
| | - Nguyen Phuoc Long
- Research Institute of Pharmaceutical Sciences, Seoul National University, Seoul, South Korea
| |
Collapse
|
13
|
Höcker O, Knierman M, Meixner J, Neusüß C. Two capillary approach for a multifunctional nanoflow sheath liquid interface for capillary electrophoresis-mass spectrometry. Electrophoresis 2020; 42:369-373. [PMID: 32776368 DOI: 10.1002/elps.202000169] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2020] [Revised: 07/23/2020] [Accepted: 08/03/2020] [Indexed: 12/18/2022]
Abstract
CE hyphenated to ESI-MS (CE-ESI-MS) is a well-established technique to analyze charged analytes in complex samples. Although various interfaces for CE-MS coupling are commercially available, the development of alternatives which combine sensitivity, simplicity, and robustness remains a topic of research. In this work, a nanoflow sheath liquid CE-MS interface with two movable capillaries inside a glass emitter is described. The setup enables a separation mode and a conditioning mode to guide the separation capillary effluent either into the electrospray or to the waste, respectively. This enables to exclude parts of the analysis from MS detection and unwanted matrix components reaching the mass spectrometer, comparable to divert valves in LC-MS coupling. Also, this function improves the overall robustness of the system by reduction of particles blocking the emitter. Preconditioning with electrospray interfering substances and even the application of coating materials for every analysis is enabled, even while the separation capillary is built into the interface with running electrospray. The functionality is demonstrated by analyses of heavy matrix bioreactor samples. Overall, this innovation offers a more convenient installation of the interface, improved handling with an extended lifetime of the emitter tips and additional functions compared to previous approaches, while keeping the higher sensitivity of nanoflow CE-MS-coupling.
Collapse
Affiliation(s)
- Oliver Höcker
- Department of Chemistry, Aalen University, Aalen, Germany
- Instrumental Analytical Chemistry and Centre for Water and Environmental Research (ZWU), Universitätsstraße, University of Duisburg-Essen, Essen, Germany
| | - Mike Knierman
- Laboratory for Experimental Medicine, Lilly Corporate Center, Eli Lilly and Company, Indianapolis, IN, USA
| | - Jens Meixner
- Agilent Technologies R&D and Marketing GmbH & Co. KG, Hewlett-Packard-Straße 8, Waldbronn, Germany
| | | |
Collapse
|
14
|
Hinkle JD, D'Ippolito RA, Panepinto MC, Wang WH, Bai DL, Shabanowitz J, Hunt DF. Unambiguous Sequence Characterization of a Monoclonal Antibody in a Single Analysis Using a Nonspecific Immobilized Enzyme Reactor. Anal Chem 2019; 91:13547-13554. [PMID: 31584792 DOI: 10.1021/acs.analchem.9b02666] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Accurate sequence characterization is essential for the development of therapeutic antibodies by the pharmaceutical industry. Presented here is a methodology to obtain comprehensive sequence analysis of a monoclonal antibody. An enzyme reactor of immobilized Aspergillopepsin I, a highly stable nonspecific protease, was used to cleave reduced antibody subunits into a peptide profile ranging from 1 to 20 kDa. Utilizing the Thermo Orbitrap Fusion's unique instrument architecture combined with state-of-the-art instrument control software allowed for dynamic instrument methods that optimally characterize eluting peptides based on their size and charge density. Using a data-dependent instrument method, both collisional dissociation and electron transfer dissociation were used to fragment the appropriate charge state of analyte peptides. The instrument layout also allowed for scans to be taken in parallel using both the ion trap and Orbitrap concurrently, thus allowing larger peptides to be analyzed in high resolution using the Orbitrap while simultaneously analyzing tryptic-like peptides using the ion trap. We harnessed these capabilities to develop a custom method to optimally fragment the eluting peptides based on their mass and charge density. Using this approach, we obtained 100% sequence coverage of the total antibody in a single chromatographic analysis, enabling unambiguous sequence assignment of all residues.
Collapse
Affiliation(s)
- Joshua D Hinkle
- Department of Chemistry , University of Virginia , Charlottesville , Virginia 22904 , United States
| | - Robert A D'Ippolito
- Department of Chemistry , University of Virginia , Charlottesville , Virginia 22904 , United States
| | - Maria C Panepinto
- Department of Chemistry , University of Virginia , Charlottesville , Virginia 22904 , United States
| | - Wei-Han Wang
- Department of Chemistry , University of Virginia , Charlottesville , Virginia 22904 , United States
| | - Dina L Bai
- Department of Chemistry , University of Virginia , Charlottesville , Virginia 22904 , United States
| | - Jeffrey Shabanowitz
- Department of Chemistry , University of Virginia , Charlottesville , Virginia 22904 , United States
| | - Donald F Hunt
- Department of Chemistry , University of Virginia , Charlottesville , Virginia 22904 , United States.,Department of Pathology , University of Virginia , Charlottesville , Virginia 22908 , United States
| |
Collapse
|
15
|
Révész Á, Rokob TA, Jeanne Dit Fouque D, Hüse D, Háda V, Turiák L, Memboeuf A, Vékey K, Drahos L. Optimal Collision Energies and Bioinformatics Tools for Efficient Bottom-up Sequence Validation of Monoclonal Antibodies. Anal Chem 2019; 91:13128-13135. [PMID: 31518108 DOI: 10.1021/acs.analchem.9b03362] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023]
Abstract
Rigorous validation of amino acid sequence is fundamental in the characterization of original and biosimilar protein biopharmaceuticals. Widely accepted workflows are based on bottom-up mass spectrometry, and they often require multiple techniques and significant manual work. Here, we demonstrate that optimization of a set of tandem mass spectroscopy (MS/MS) collision energies and automated combination of all available information in the measurements can increase the sequence validated by one technique close to the inherent limits. We created a software (called "Serac") that consumes results of the Mascot database search engine and identifies the amino acids validated by bottom-up MS/MS experiments using the most rigorous, industrially acceptable definition of sequence coverage (we term this "confirmed sequence coverage"). The software can combine spectra at the level of amino acids or fragment ions to exploit complementarity, provides full transparency to justify validation, and reduces manual effort. With its help, we investigated collision energy dependence of confirmed sequence coverage of individual peptides and full proteins on trypsin-digested monoclonal antibody samples (rituximab and trastuzumab). We found the energy dependence to be modest, but we demonstrated the benefit of using spectra taken at multiple energies. We describe a workflow based on 2-3 LC-MS/MS runs, carefully selected collision energies, and a fragment ion level combination, which yields ∼85% confirmed sequence coverage, 25%-30% above that from a basic proteomics protocol. Further increase can mainly be expected from alternative digestion enzymes or fragmentation techniques, which can be seamlessly integrated to the processing, thereby allowing effortless validation of full sequences.
Collapse
Affiliation(s)
- Ágnes Révész
- MS Proteomics Research Group, Research Centre for Natural Sciences , Hungarian Academy of Sciences , Magyar Tudósok körútja 2 , H-1117 , Budapest , Hungary
| | - Tibor András Rokob
- Theoretical Chemistry Research Group, Research Centre for Natural Sciences , Hungarian Academy of Sciences , Magyar Tudósok körútja 2 , H-1117 , Budapest , Hungary
| | - Dany Jeanne Dit Fouque
- UMR CNRS 6521, CEMCA , Université de Bretagne Occidentale , 6 Av. Le Gorgeu , 29238 Brest Cedex 3 , France
| | - Dániel Hüse
- Analytical Department of Biotechnology , Gedeon Richter Plc , POB 27, H-1475 Budapest 10 , Hungary
| | - Viktor Háda
- Analytical Department of Biotechnology , Gedeon Richter Plc , POB 27, H-1475 Budapest 10 , Hungary
| | - Lilla Turiák
- MS Proteomics Research Group, Research Centre for Natural Sciences , Hungarian Academy of Sciences , Magyar Tudósok körútja 2 , H-1117 , Budapest , Hungary
| | - Antony Memboeuf
- UMR CNRS 6521, CEMCA , Université de Bretagne Occidentale , 6 Av. Le Gorgeu , 29238 Brest Cedex 3 , France
| | - Károly Vékey
- MS Proteomics Research Group, Research Centre for Natural Sciences , Hungarian Academy of Sciences , Magyar Tudósok körútja 2 , H-1117 , Budapest , Hungary
| | - László Drahos
- MS Proteomics Research Group, Research Centre for Natural Sciences , Hungarian Academy of Sciences , Magyar Tudósok körútja 2 , H-1117 , Budapest , Hungary
| |
Collapse
|
16
|
Szarka M, Szigeti M, Guttman A. Imaging Laser-Induced Fluorescence Detection at the Taylor Cone of Electrospray Ionization Mass Spectrometry. Anal Chem 2019; 91:7738-7743. [DOI: 10.1021/acs.analchem.9b01028] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Affiliation(s)
- Máte Szarka
- Horváth Csaba Memorial Laboratory of Bioseparation Sciences, Research Center for Molecular Medicine, Faculty of Medicine, University of Debrecen, 98 Nagyerdei krt, Debrecen 4032, Hungary
| | - Márton Szigeti
- Horváth Csaba Memorial Laboratory of Bioseparation Sciences, Research Center for Molecular Medicine, Faculty of Medicine, University of Debrecen, 98 Nagyerdei krt, Debrecen 4032, Hungary
- Translational Glycomics Laboratory, Research Institute of Biomolecular and Chemical Engineering, University of Pannonia, 10 Egyetem Street, Veszprem 8200, Hungary
| | - András Guttman
- Horváth Csaba Memorial Laboratory of Bioseparation Sciences, Research Center for Molecular Medicine, Faculty of Medicine, University of Debrecen, 98 Nagyerdei krt, Debrecen 4032, Hungary
- Translational Glycomics Laboratory, Research Institute of Biomolecular and Chemical Engineering, University of Pannonia, 10 Egyetem Street, Veszprem 8200, Hungary
| |
Collapse
|
17
|
Faserl K, Sarg B, Gruber P, Lindner HH. Investigating capillary electrophoresis-mass spectrometry for the analysis of common post-translational modifications. Electrophoresis 2018; 39:1208-1215. [PMID: 29389038 PMCID: PMC6001557 DOI: 10.1002/elps.201700437] [Citation(s) in RCA: 30] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2017] [Revised: 01/24/2018] [Accepted: 01/24/2018] [Indexed: 12/26/2022]
Abstract
Capillary electrophoresis coupled to mass spectrometry is a very efficient analytical method for the analysis of post-translational modifications because of its high separation efficiency and high detection sensitivity. Here we applied CE-MS using three differently coated separation capillaries for in-depth analysis of a set of 70 synthetic post-translationally modified peptides (including phosphorylation, acetylation, methylation, and nitration). We evaluated the results in terms of peptide detection and separation characteristics and found that the use of a neutrally coated capillary resulted in highest overall signal intensity of singly modified peptides. In contrast, the use of a bare-fused silica capillary was superior in the identification of multi-phosphorylated peptides (12 out of 15 were identified). Fast separations of approximately 12 min could be achieved using a positively coated capillary, however, at the cost of separation efficiency. A comparison to nanoLC-MS revealed that multi-phosphorylated peptides interact with the RP material very poorly so that these peptides were either washed out or elute as very broad peaks from the nano column which results in a reduced peptide identification rate (7 out of 15). Moreover, the methods applied were found to be very well suited for the analysis of the acetylated, nitrated and methylated peptides. All 36 synthetic peptides, which exhibit one of those modifications, could be identified regardless of the method applied. As a final step in this study and as a proof of principle, the phosphoproteome enriched from PC-12 pheochromocytoma cells was analyzed by CE-MS resulting in 5686 identified and 4088 quantified phosphopeptides. We compared the characterized analytes to those identified by a nanoLC-MS proteomics study and found that less than one third of the phosphopeptides were identical, which demonstrates the benefit by combining different approaches quite impressively.
Collapse
Affiliation(s)
- Klaus Faserl
- Division of Clinical BiochemistryBiocenterInnsbruck Medical UniversityInnsbruckTirolAustria
| | - Bettina Sarg
- Division of Clinical BiochemistryBiocenterInnsbruck Medical UniversityInnsbruckTirolAustria
| | - Peter Gruber
- Division of Medical BiochemistryBiocenterInnsbruck Medical UniversityInnsbruckTirolAustria
| | - Herbert H. Lindner
- Division of Clinical BiochemistryBiocenterInnsbruck Medical UniversityInnsbruckTirolAustria
| |
Collapse
|
18
|
Xiao X, Wang W, Zhang Y, Jia L. Facile preparation of fibrin coated open tubular column for characterization of monoclonal antibody variants by capillary electrochromatography. J Pharm Biomed Anal 2017; 140:377-383. [DOI: 10.1016/j.jpba.2017.03.014] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2017] [Revised: 03/06/2017] [Accepted: 03/09/2017] [Indexed: 01/13/2023]
|
19
|
Dawod M, Arvin NE, Kennedy RT. Recent advances in protein analysis by capillary and microchip electrophoresis. Analyst 2017; 142:1847-1866. [PMID: 28470231 PMCID: PMC5516626 DOI: 10.1039/c7an00198c] [Citation(s) in RCA: 91] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Abstract
This review article describes the significant recent advances in the analysis of proteins by capillary and microchip electrophoresis during the period from mid-2014 to early 2017. This review highlights the progressions, new methodologies, innovative instrumental modifications, and challenges for efficient protein analysis in human specimens, animal tissues, and plant samples. The protein analysis fields covered in this review include analysis of native, reduced, and denatured proteins in addition to Western blotting, protein therapeutics and proteomics.
Collapse
Affiliation(s)
- Mohamed Dawod
- Department of Chemistry, University of Michigan, 930 N. University Ave, Ann Arbor, Michigan 48109, USA.
| | | | | |
Collapse
|
20
|
Abstract
Protein glycosylation is one of the most important posttranslational modifications. Numerous biological functions are related to protein glycosylation. However, analytical challenges remain in the glycoprotein analysis. To overcome the challenges associated with glycoprotein analysis, many analytical techniques were developed in recent years. Enrichment methods were used to improve the sensitivity of detection, while HPLC and mass spectrometry methods were developed to facilitate the separation of glycopeptides/proteins and enhance detection, respectively. Fragmentation techniques applied in modern mass spectrometers allow the structural interpretation of glycopeptides/proteins, while automated software tools started replacing manual processing to improve the reliability and throughput of the analysis. In this chapter, the current methodologies of glycoprotein analysis were discussed. Multiple analytical techniques are compared, and advantages and disadvantages of each technique are highlighted.
Collapse
|
21
|
Týčová A, Ledvina V, Klepárník K. Recent advances in CE-MS coupling: Instrumentation, methodology, and applications. Electrophoresis 2016; 38:115-134. [DOI: 10.1002/elps.201600366] [Citation(s) in RCA: 76] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2016] [Revised: 08/30/2016] [Accepted: 08/30/2016] [Indexed: 12/17/2022]
Affiliation(s)
- Anna Týčová
- Institute of Analytical Chemistry; Czech Academy of Sciences; Brno Czech Republic
| | - Vojtěch Ledvina
- Institute of Analytical Chemistry; Czech Academy of Sciences; Brno Czech Republic
| | - Karel Klepárník
- Institute of Analytical Chemistry; Czech Academy of Sciences; Brno Czech Republic
| |
Collapse
|
22
|
Štěpánová S, Kašička V. Recent applications of capillary electromigration methods to separation and analysis of proteins. Anal Chim Acta 2016; 933:23-42. [DOI: 10.1016/j.aca.2016.06.006] [Citation(s) in RCA: 78] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2016] [Revised: 05/10/2016] [Accepted: 06/03/2016] [Indexed: 10/21/2022]
|
23
|
Cutting-edge capillary electrophoresis characterization of monoclonal antibodies and related products. J Chromatogr B Analyt Technol Biomed Life Sci 2016; 1032:61-78. [PMID: 27265157 DOI: 10.1016/j.jchromb.2016.05.028] [Citation(s) in RCA: 63] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2016] [Revised: 05/12/2016] [Accepted: 05/17/2016] [Indexed: 01/22/2023]
Abstract
Out of all categories, monoclonal antibodies (mAbs), biosimilar, antibody-drug conjugates (ADCs) and Fc-fusion proteins attract the most interest due to their strong therapeutic potency and specificity. Because of their intrinsic complexity due to a large number of micro-heterogeneities, there is a crucial need of analytical methods to provide comprehensive in-depth characterization of these molecules. CE presents some obvious benefits as high resolution separation and miniaturized format to be widely applied to the analysis of biopharmaceuticals. CE is an effective method for the separation of proteins at different levels. capillary gel electrophoresis (CGE), capillary isoelectric focusing (cIEF) and capillary zone electrophoresis (CZE) have been particularly relevant for the characterization of size and charge variants of intact and reduced mAbs, while CE-MS appears to be a promising analytical tool to assess the primary structure of mAbs and related products. This review will be dedicated to detail the current and state-of-the-art CE-based methods for the characterization of mAbs and related products.
Collapse
|
24
|
Fekete S, Guillarme D, Sandra P, Sandra K. Chromatographic, Electrophoretic, and Mass Spectrometric Methods for the Analytical Characterization of Protein Biopharmaceuticals. Anal Chem 2015; 88:480-507. [DOI: 10.1021/acs.analchem.5b04561] [Citation(s) in RCA: 171] [Impact Index Per Article: 19.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Affiliation(s)
- Szabolcs Fekete
- School
of Pharmaceutical Sciences, University of Geneva, University of Lausanne, Boulevard d’Yvoy 20, 1211 Geneva 4, Switzerland
| | - Davy Guillarme
- School
of Pharmaceutical Sciences, University of Geneva, University of Lausanne, Boulevard d’Yvoy 20, 1211 Geneva 4, Switzerland
| | - Pat Sandra
- Research Institute for Chromatography (RIC), President Kennedypark 26, 8500 Kortrijk, Belgium
| | - Koen Sandra
- Research Institute for Chromatography (RIC), President Kennedypark 26, 8500 Kortrijk, Belgium
| |
Collapse
|
25
|
Pang Y, Wang WH, Reid GE, Hunt DF, Bruening ML. Pepsin-Containing Membranes for Controlled Monoclonal Antibody Digestion Prior to Mass Spectrometry Analysis. Anal Chem 2015; 87:10942-9. [PMID: 26455365 DOI: 10.1021/acs.analchem.5b02739] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
Monoclonal antibodies (mAbs) are the fastest growing class of therapeutic drugs, because of their high specificities to target cells. Facile analysis of therapeutic mAbs and their post-translational modifications (PTMs) is essential for quality control, and mass spectrometry (MS) is the most powerful tool for antibody characterization. This study uses pepsin-containing nylon membranes as controlled proteolysis reactors for mAb digestion prior to ultrahigh-resolution Orbitrap MS analysis. Variation of the residence times (from 3 ms to 3 s) of antibody solutions in the membranes yields "bottom-up" (1-2 kDa) to "middle-down" (5-15 kDa) peptide sizes within less than 10 min. These peptides cover the entire sequences of Trastuzumab and a Waters antibody, and a proteolytic peptide comprised of 140 amino acids from the Waters antibody contains all three complementarity determining regions on the light chain. This work compares the performance of "bottom-up" (in-solution tryptic digestion), "top-down" (intact protein fragmentation), and "middle-down" (in-membrane digestion) analysis of an antibody light chain. Data from tandem MS show 99%, 55%, and 99% bond cleavage for "bottom-up", "top-down", and "middle-down" analyses, respectively. In-membrane digestion also facilitates detection of PTMs such as oxidation, deamidation, N-terminal pyroglutamic acid formation, and glycosylation. Compared to "bottom-up" and "top-down" approaches for antibody characterization, in-membrane digestion uses minimal sample preparation time, and this technique also yields high peptide and sequence coverage for the identification of PTMs.
Collapse
Affiliation(s)
- Yongle Pang
- Department of Chemistry, Michigan State University , East Lansing, Michigan 48824, United States
| | - Wei-Han Wang
- Department of Chemistry, University of Virginia , Charlottesville, Virginia 22904, United States
| | - Gavin E Reid
- School of Chemistry, Department of Biochemistry and Molecular Biology, Bio21 Molecular Science & Biotechnology Institute, The University of Melbourne , Parkville, Victoria 3010, Australia
| | - Donald F Hunt
- Department of Chemistry, University of Virginia , Charlottesville, Virginia 22904, United States.,Department of Pathology, Health Sciences Center, University of Virginia , Charlottesville, Virginia 22908, United States
| | - Merlin L Bruening
- Department of Chemistry, Michigan State University , East Lansing, Michigan 48824, United States
| |
Collapse
|