1
|
Cho SG, Lee JE, Kim HY, Song HC, Kim YH. Association between myocardial ischemia and plaque characteristics in chronic total occlusion. J Nucl Cardiol 2023; 30:388-398. [PMID: 35836093 DOI: 10.1007/s12350-022-03020-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2022] [Accepted: 05/02/2022] [Indexed: 10/17/2022]
Abstract
BACKGROUND Myocardial ischemia varies in chronic total occlusion (CTO) despite the occluded artery. We analyzed whether it is associated with the plaque characteristics of the occluded segment. METHODS We retrospectively enrolled 100 patients with CTO who underwent myocardial perfusion single-photon emission computed tomography (SPECT) and coronary computed tomography angiography (CCTA) within 2 months. CTO-related ischemia was classified as moderate to severe (summed difference score [SDS] of the CTO territory ≥ 5) or mild or none (SDS < 5) on SPECT. Using CCTA, the atherosclerotic plaques of the occluded segment were subdivided into low-density (- 100-30 HU), intermediate-density (31-350 HU), and high-density (351-1000 HU) plaques. The plaque composition was compared according to the severity of CTO-related ischemia. RESULTS Moderate-to-severe CTO-related ischemia (n = 23) showed significantly higher proportion of intermediate-density plaques (72.4% vs. 64.0%), intermediate/low-density (7.10 vs. 3.65) and intermediate-to-high/low-density (7.78 vs. 3.80) plaque ratios, frequent shorter occlusion (30% vs. 6%), and lower volume (26.5 mm3 vs. 58.8 mm3) and proportion (11.4% vs. 20.8%) of low-density plaques. Multivariable analysis revealed significant associations between higher proportion of intermediate-density plaques and moderate-to-severe CTO-related ischemia, independent of occlusion length. CONCLUSION Higher proportion of intermediate-density plaques in the occluded segment was associated with the moderate-to-severe CTO-related ischemia.
Collapse
Affiliation(s)
- Sang-Geon Cho
- Department of Nuclear Medicine, Chonnam National University Hospital, 42, Jebong-ro, Dong-gu, Gwangju, 61469, Republic of Korea
| | - Jong Eun Lee
- Department of Radiology, Chonnam National University Hospital, Gwangju, Republic of Korea
| | - Hyung Yoon Kim
- Department of Cardiovascular Medicine, Chonnam National University Hospital, Gwangju, Republic of Korea
| | - Ho-Chun Song
- Department of Nuclear Medicine, Chonnam National University Hospital, 42, Jebong-ro, Dong-gu, Gwangju, 61469, Republic of Korea.
- Department of Nuclear Medicine, Chonnam National University Medical School, Gwangju, Republic of Korea.
| | - Yun-Hyeon Kim
- Department of Radiology, Chonnam National University Hospital, Gwangju, Republic of Korea
- Department of Radiology, Chonnam National University Medical School, Gwangju, Republic of Korea
| |
Collapse
|
2
|
Cho SG, Lee SJ, Na MH, Choi YY, Bom HHS. Comparison of diagnostic accuracy of PET-derived myocardial blood flow parameters: A meta-analysis. J Nucl Cardiol 2020; 27:1955-1966. [PMID: 30390243 DOI: 10.1007/s12350-018-01476-z] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2018] [Accepted: 09/24/2018] [Indexed: 11/25/2022]
Abstract
BACKGROUND Although absolute quantification of myocardial blood flow (MBF) by positron emission tomography provides additive diagnostic value to visual analysis of perfusion defect, diagnostic accuracy of different MBF parameters remain unclear. METHODS Clinical studies regarding the diagnostic accuracy of hyperemic MBF (hMBF), myocardial flow reserve (MFR) and/or relative flow reserve (RFR) were searched and systematically reviewed. On a per-vessel basis, pooled measures of the parameters' diagnostic performances were analyzed, regarding significant coronary stenosis defined by fractional flow reserve or diameter stenosis. RESULTS Ten studies (2,522 arteries from 1,099 patients) were finally included. Pooled sensitivity [95% confidence interval (CI)] was 0.853 (0.821-0.881) for hMBF, 0.755 (0.713-0.794) for MFR, and 0.636 (0.539-0.726) for RFR. Pooled specificity (95% CI) was 0.844 (0.827-0.860) for hMBF, 0.804 (0.784-0.824) for MFR, and 0.897 (0.860-0.926) for RFR. Pooled area under the curve ± standard error was 0.900 ± 0.020 for hMBF, 0.830 ± 0.026 for MFR, and 0.873 ± 0.048 for RFR. CONCLUSIONS hMBF showed the best sensitivity while RFR showed the best specificity in the diagnosis of significant coronary stenosis. MFR was less sensitive than hMBF and less specific than hMBF and RFR.
Collapse
Affiliation(s)
- Sang-Geon Cho
- Department of Nuclear Medicine, Chonnam National University Hospital, 42, Jebong-ro, Dong-gu, Gwangju, 61469, Republic of Korea.
| | - Soo Jin Lee
- Department of Nuclear Medicine, Hanyang University Medical Center, 222-1, Wangsimni-ro Seongdong-gu, Seoul, 04763, Republic of Korea
| | - Myung Hwan Na
- Department of Statistics, Chonnam National University, 45, Yongbong-ro, Buk-gu, Kwangju, 61186, Republic of Korea
| | - Yun Young Choi
- Department of Nuclear Medicine, Hanyang University Medical Center, 222-1, Wangsimni-ro Seongdong-gu, Seoul, 04763, Republic of Korea.
| | - Henry Hee-Seung Bom
- Department of Nuclear Medicine, Chonnam National University Hwasun Hospital, 322, Seoyang-ro Hwasun-eup, Hwasun-gun, Jeonnam, 58128, Republic of Korea.
| |
Collapse
|
3
|
EANM procedural guidelines for PET/CT quantitative myocardial perfusion imaging. Eur J Nucl Med Mol Imaging 2020; 48:1040-1069. [PMID: 33135093 PMCID: PMC7603916 DOI: 10.1007/s00259-020-05046-9] [Citation(s) in RCA: 61] [Impact Index Per Article: 15.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2020] [Accepted: 09/17/2020] [Indexed: 12/19/2022]
Abstract
The use of cardiac PET, and in particular of quantitative myocardial perfusion PET, has been growing during the last years, because scanners are becoming widely available and because several studies have convincingly demonstrated the advantages of this imaging approach. Therefore, there is a need of determining the procedural modalities for performing high-quality studies and obtaining from this demanding technique the most in terms of both measurement reliability and clinical data. Although the field is rapidly evolving, with progresses in hardware and software, and the near perspective of new tracers, the EANM Cardiovascular Committee found it reasonable and useful to expose in an updated text the state of the art of quantitative myocardial perfusion PET, in order to establish an effective use of this modality and to help implementing it on a wider basis. Together with the many steps necessary for the correct execution of quantitative measurements, the importance of a multiparametric approach and of a comprehensive and clinically useful report have been stressed.
Collapse
|
4
|
Malkasian S, Hubbard L, Abbona P, Dertli B, Kwon J, Molloi S. Vessel-specific coronary perfusion territories using a CT angiogram with a minimum cost path technique and its direct comparison to the American Heart Association 17-segment model. Eur Radiol 2020; 30:3334-3345. [PMID: 32072257 DOI: 10.1007/s00330-020-06697-w] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2019] [Revised: 01/10/2020] [Accepted: 01/31/2020] [Indexed: 10/25/2022]
Abstract
OBJECTIVES This study compared the accuracy of an automated, vessel-specific minimum cost path (MCP) myocardial perfusion territory assignment technique as compared with the standard American Heart Association 17-segment (AHA) model. METHODS Six swine (42 ± 9 kg) were used to evaluate the accuracy of the MCP technique and the AHA method. In each swine, a dynamic acquisition, comprised of twenty consecutive whole heart volume scans, was acquired with a computed tomography scanner, following peripheral injection of contrast material. From this acquisition, MCP and AHA perfusion territories were determined, for the left (LCA) and right (RCA) coronary arteries. Each animal underwent additional dynamic acquisitions, consisting of twenty consecutive volume scans, following direct intracoronary contrast injection into the LCA or RCA. These images were used as the reference standard (REF) LCA and RCA perfusion territories. The MCP and AHA techniques' perfusion territories were then quantitatively compared with the REF perfusion territories. RESULTS The myocardial mass of MCP perfusion territories (MMCP) was related to the mass of reference standard perfusion territories (MREF) by MMCP = 0.99MREF + 0.39 g (r = 1.00; R2 = 1.00). The mass of AHA perfusion territories (MAHA) was related to MREF by MAHA = 0.81MREF + 5.03 g (r = 0.99; R2 = 0.98). CONCLUSION The vessel-specific MCP myocardial perfusion territory assignment technique more accurately quantifies LCA and RCA perfusion territories as compared with the current standard AHA 17-segment model. Therefore, it can potentially provide a more comprehensive and patient-specific evaluation of coronary artery disease. KEY POINTS • The minimum cost path (MCP) technique accurately determines left and right coronary artery perfusion territories, as compared with the American Heart Association 17-segment (AHA) model. • The minimum cost path (MCP) technique could be applied to cardiac computed-tomography angiography images to accurately determine patient-specific left and right coronary artery perfusion territories. • The American Heart Association 17-segment (AHA) model often fails to accurately determine left and right coronary artery perfusion territories, especially in the inferior and inferoseptal walls of the left ventricular myocardium.
Collapse
Affiliation(s)
- Shant Malkasian
- Department of Radiological Sciences, Medical Sciences I, B-14, University of California, Irvine, CA, 92697, USA
| | - Logan Hubbard
- Department of Radiological Sciences, Medical Sciences I, B-14, University of California, Irvine, CA, 92697, USA
| | - Pablo Abbona
- Department of Radiological Sciences, Medical Sciences I, B-14, University of California, Irvine, CA, 92697, USA
| | - Brian Dertli
- Department of Radiological Sciences, Medical Sciences I, B-14, University of California, Irvine, CA, 92697, USA
| | - Jungnam Kwon
- Department of Radiological Sciences, Medical Sciences I, B-14, University of California, Irvine, CA, 92697, USA
| | - Sabee Molloi
- Department of Radiological Sciences, Medical Sciences I, B-14, University of California, Irvine, CA, 92697, USA.
| |
Collapse
|
5
|
Cho SG, Kim HS, Cho JY, Kim JH, Bom HS. Diagnostic Value of Lesion-specific Measurement of Myocardial Blood Flow Using Hybrid PET/CT. J Cardiovasc Imaging 2020; 28:94-105. [PMID: 32052606 PMCID: PMC7114456 DOI: 10.4250/jcvi.2019.0087] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2019] [Revised: 10/22/2019] [Accepted: 11/27/2019] [Indexed: 01/27/2023] Open
Abstract
BACKGROUND We evaluated whether lesion-specific measurement of myocardial blood flow (MBF) and flow reserve (MFR) by hybrid imaging of myocardial perfusion positron emission tomography (PET) and coronary computed tomography (CT) can provide additional diagnostic value. METHODS Forty-three patients with stable angina underwent N-13 ammonia PET and coronary CT before invasive coronary angiography (CAG). The lesion-specific MBF was calculated from the average MBF of the myocardial segments downstream of a coronary stenosis using hybrid PET/CT images. The hyperemic MBF, resting MBF, and MFR were measured for the left anterior descending artery (LAD) using conventional and lesion-specific methods. The diagnostic accuracy was compared between the two methods for significant LAD stenoses (≥ 70% reference diameter on CAG). RESULTS There were 19 significant LAD stenoses. The sensitivity, specificity, negative predictive value, positive predictive value, and accuracy were 71%, 68%, 74%, 65%, and 70% for conventional hyperemic MBF (optimal cutoff = 2.15 mL/min/g), 79%, 63%, 74%, 65%, and 70% for conventional MFR (optimal cutoff = 1.82), 83%, 74%, 80%, 78%, and 80% for lesion-specific hyperemic MBF (optimal cutoff = 1.75 mL/min/g), and 79%, 79%, 83%, 75%, and 79% for lesion-specific MFR (optimal cutoff = 1.86), respectively. The lesion-specific measurement was more accurate and had a better linear correlation with anatomical stenosis severity for both hyperemic MBF and MFR. CONCLUSIONS Lesion-specific measurement using hybrid PET/CT imaging showed significant improvement in the diagnostic accuracy of PET-measured hyperemic MBF and MFR.
Collapse
Affiliation(s)
- Sang Geon Cho
- Department of Nuclear Medicine, Chonnam National University Hospital, Gwangju, Korea
| | - Hyeon Sik Kim
- Medical Photonics Research Center, Korea Photonics Technology Institute, Gwangju, Korea
| | - Jae Yeong Cho
- Department of Cardiovascular Medicine, Chonnam National University Hospital, Gwangju, Korea
| | - Ju Han Kim
- Department of Cardiovascular Medicine, Chonnam National University Hospital, Gwangju, Korea
| | - Hee Seung Bom
- Department of Nuclear Medicine, Chonnam National University Hwasun Hospital, Jeollanam-do, Korea.
| |
Collapse
|
6
|
15-O-water myocardial flow reserve PET and CT angiography by full hybrid PET/CT as a potential alternative to invasive angiography. Int J Cardiovasc Imaging 2018; 34:2011-2022. [PMID: 30066164 DOI: 10.1007/s10554-018-1420-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/09/2018] [Accepted: 07/23/2018] [Indexed: 01/14/2023]
Abstract
Combined myocardial flow reserve (MFR) by PET and CT coronary angiography (CTA) is a promising tool for assessment of coronary artery disease. Prior analyses of MFR/CTA has been performed as side-by-side interpretation, not as volume rendered, full hybrid analysis, with fused MFR/CTA. We aimed to: (i) establish a method for full hybrid analysis of MFR/CTA, (ii) validate the inter- and intra-observer reproducibility of MFR values, and (iii) determine the diagnostic value of side-by-side versus full hybrid MFR/CTA with 15-O-water PET. Forty-four outpatients scheduled for invasive coronary angiography (ICA) were enrolled prospectively. All underwent rest/stress 15-O-water PET/CTA with ICA as reference. Within two observers of different experience, the Pearson r at global and territorial level exceeded 0.953 for rest, stress, and MFR values, as determined by Carimas software. Within and between observers, the mean differences between rest, stress, and MFR values were close to zero and the confidence intervals for 95% limits of agreement were narrow. The diagnostic performance of full hybrid PET/CTA did not outperform the side-by-side approach, but performed better than MFR without CTA at vessel level: specificity 93% (95% confidence limits: 89-97%) versus 76% (64-88%), p = 0.0004; positive predictive value 71% (55-86%) versus 51% (37-65%), p = 0.0001; accuracy 90% (84-95%) versus 77% (69-84%), p = 0.0009. MFR showed high reproducibility within and between observers of different experience. The full hybrid model was not superior to side-by-side interpretation of MFR/CTA, but proved better than MFR alone at vessel level with regard to specificity, positive predictive value, and accuracy.
Collapse
|
7
|
Malkasian S, Hubbard L, Dertli B, Kwon J, Molloi S. Quantification of vessel-specific coronary perfusion territories using minimum-cost path assignment and computed tomography angiography: Validation in a swine model. J Cardiovasc Comput Tomogr 2018; 12:425-435. [PMID: 30042078 DOI: 10.1016/j.jcct.2018.06.006] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/23/2018] [Revised: 05/25/2018] [Accepted: 06/15/2018] [Indexed: 11/17/2022]
Abstract
BACKGROUND As combined morphological and physiological assessment of coronary artery disease (CAD) is necessary to reliably resolve CAD severity, the objective of this study was to validate an automated minimum-cost path assignment (MCP) technique which enables accurate, vessel-specific assignment of the left (LCA) and right (RCA) coronary perfusion territories using computed tomography (CT) angiography data for both left and right ventricles. METHODS Six swine were used to validate the MCP technique. In each swine, a dynamic acquisition comprised of twenty consecutive volume scans was acquired with a 320-slice CT scanner following peripheral injection of contrast material. From this acquisition the MCP technique was used to automatically assign LCA and RCA perfusion territories for the left and right ventricles, independently. Each animal underwent another dynamic CT acquisition following direct injection of contrast material into the LCA or RCA. Using this acquisition, reference standard LCA and RCA perfusion territories were isolated from the myocardial blush. The accuracy of the MCP technique was evaluated by quantitatively comparing the MCP-derived LCA and RCA perfusion territories to these reference standard territories. RESULTS All MCP perfusion territory masses (MassMCP) and all reference standard perfusion territory masses (MassRS) in the left ventricle were related by MassMCP = 0.99MassRS+0.35 g (r = 1.00). MassMCP and MassRS in the right ventricle were related by MassMCP = 0.94MassRS+0.39 g (r = 0.96). CONCLUSION The MCP technique was validated in a swine animal model and has the potential to be used for accurate, vessel-specific assignment of LCA and RCA perfusion territories in both the left and right ventricular myocardium using CT angiography data.
Collapse
Affiliation(s)
- Shant Malkasian
- Department of Radiological Sciences, University of California Irvine, Irvine, CA, 92697, USA
| | - Logan Hubbard
- Department of Radiological Sciences, University of California Irvine, Irvine, CA, 92697, USA
| | - Brian Dertli
- Department of Radiological Sciences, University of California Irvine, Irvine, CA, 92697, USA
| | - Jungnam Kwon
- Department of Radiological Sciences, University of California Irvine, Irvine, CA, 92697, USA
| | - Sabee Molloi
- Department of Radiological Sciences, University of California Irvine, Irvine, CA, 92697, USA.
| |
Collapse
|
8
|
Mikkelsen EFR, Mariager CØ, Nørlinger T, Qi H, Schulte RF, Jakobsen S, Frøkiær J, Pedersen M, Stødkilde-Jørgensen H, Laustsen C. Hyperpolarized [1- 13C]-acetate Renal Metabolic Clearance Rate Mapping. Sci Rep 2017; 7:16002. [PMID: 29167446 PMCID: PMC5700138 DOI: 10.1038/s41598-017-15929-x] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2017] [Accepted: 11/03/2017] [Indexed: 01/02/2023] Open
Abstract
11C-acetate is a positron emission tomography (PET) tracer of oxidative metabolism, whereas hyperpolarized 13C-acetate can be used in magnetic resonance imaging (MRI) for investigating specific metabolic processes. The aims of this study were to examine if the kinetic formalism of 11C-acetate PET in the kidneys is comparable to that of 13C-acetate MRI, and to compare the dynamic metabolic information of hyperpolarized 13C-acetate MRI with that obtained with 11C-acetate PET. Rats were examined with dynamic hyperpolarized 13C-acetate MRI or 11C-acetate PET before and after intravenous injection of furosemide, a loop diuretic known to alter both the hemodynamics and oxygen consumption in the kidney. The metabolic clearance rates (MCR) were estimated and compared between the two modalities experimentally in vivo and in simulations. There was a clear dependency on the mean transit time and MCR for both 13C-acetate and 11C-acetate following furosemide administration, while no dependencies on the apparent renal perfusion were observed. This study demonstrated that hyperpolarized 13C-acetate MRI is feasible for measurements of the intrarenal energetic demand via the MCR, and that the quantitative measures are correlated with those measured by 11C-acetate PET, even though the temporal window is more than 30 times longer with 11C-acetate.
Collapse
Affiliation(s)
- Emmeli F R Mikkelsen
- MR Research Centre, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200, Aarhus N, Denmark.,Comparative Medicine Lab, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200, Aarhus N, Denmark
| | | | - Thomas Nørlinger
- MR Research Centre, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200, Aarhus N, Denmark.,Comparative Medicine Lab, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200, Aarhus N, Denmark
| | - Haiyun Qi
- MR Research Centre, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200, Aarhus N, Denmark
| | - Rolf F Schulte
- GE healthcare, Freisinger Landstraße 50, 85748, Munich, Germany
| | - Steen Jakobsen
- Department of Nuclear Medicine and PET Center, Aarhus University Hospital, Nørrebrogade, 8000, Aarhus C, Denmark
| | - Jørgen Frøkiær
- Department of Nuclear Medicine and PET Center, Aarhus University Hospital, Nørrebrogade, 8000, Aarhus C, Denmark
| | - Michael Pedersen
- Comparative Medicine Lab, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200, Aarhus N, Denmark
| | - Hans Stødkilde-Jørgensen
- MR Research Centre, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200, Aarhus N, Denmark
| | - Christoffer Laustsen
- MR Research Centre, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200, Aarhus N, Denmark.
| |
Collapse
|
9
|
Clinical use of quantitative cardiac perfusion PET: rationale, modalities and possible indications. Position paper of the Cardiovascular Committee of the European Association of Nuclear Medicine (EANM). Eur J Nucl Med Mol Imaging 2016; 43:1530-45. [PMID: 26846913 DOI: 10.1007/s00259-016-3317-5] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2016] [Accepted: 01/12/2016] [Indexed: 02/06/2023]
Abstract
Until recently, PET was regarded as a luxurious way of performing myocardial perfusion scintigraphy, with excellent image quality and diagnostic capabilities that hardly justified the additional cost and procedural effort. Quantitative perfusion PET was considered a major improvement over standard qualitative imaging, because it allows the measurement of parameters not otherwise available, but for many years its use was confined to academic and research settings. In recent years, however, several factors have contributed to the renewal of interest in quantitative perfusion PET, which has become a much more readily accessible technique due to progress in hardware and the availability of dedicated and user-friendly platforms and programs. In spite of this evolution and of the growing evidence that quantitative perfusion PET can play a role in the clinical setting, there are not yet clear indications for its clinical use. Therefore, the Cardiovascular Committee of the European Association of Nuclear Medicine, starting from the experience of its members, decided to examine the current literature on quantitative perfusion PET to (1) evaluate the rationale for its clinical use, (2) identify the main methodological requirements, (3) identify the remaining technical difficulties, (4) define the most reliable interpretation criteria, and finally (5) tentatively delineate currently acceptable and possibly appropriate clinical indications. The present position paper must be considered as a starting point aiming to promote a wider use of quantitative perfusion PET and to encourage the conception and execution of the studies needed to definitely establish its role in clinical practice.
Collapse
|