1
|
Meng Q, Wan L, Duan F, Wang D, Tao J, Wang H. Mitral Annulus Geometry and Dynamic Motion Changes in Patients With Aortic Regurgitation: A Three-Dimensional Transesophageal Echocardiographic Study. J Cardiothorac Vasc Anesth 2022; 36:4001-4009. [PMID: 35811278 DOI: 10.1053/j.jvca.2022.05.020] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/31/2022] [Revised: 05/09/2022] [Accepted: 05/13/2022] [Indexed: 11/11/2022]
Abstract
OBJECTIVE The aim of the present study was to investigate the mitral annulus (MA) geometry and dynamic motion changes in patients with aortic regurgitation (AR) before and after aortic valve replacement (AVR). Moreover, the difference in the effect of the type of prosthetic aortic valve on MA was compared. DESIGN Prospective observational study. SETTING Cardiac operating room at a single hospital. PARTICIPANTS Eighty-two patients with isolated moderate-to-severe AR who underwent AVR. Forty patients with normal valves were enrolled as controls. INTERVENTIONS None. MEASUREMENTS AND MAIN RESULTS The MA geometry and dynamic motion throughout the cardiac cycle were evaluated semiautomatically by three-dimensional transesophageal echocardiography. The severity of functional mitral regurgitation was intraoperatively evaluated. All patients were divided into 2 groups depending on the type of prosthetic valve (mechanical valve and bioprosthetic valve groups). Before AVR, compared with the control group without AR, the AR group demonstrated larger MA dimensions and the MA geometry was flatter. The contraction fraction of the MA area, perimeter, and height during the whole cardiac cycle were larger in the AR group (p < 0.05 for all). After AVR, most MA geometric and dynamic parameters decreased and functional mitral regurgitation also improved. In the postoperative subset analyses, the mechanical valve group showed a larger contraction fraction of the MA area and perimeter than the bioprosthetic valve group (p < 0.05 for both). CONCLUSIONS The MA geometry and dynamic motion changed markedly in patients with AR. These spatial and dynamic changes were restored to a certain extent after surgical correction of the aortic valve. However, the effects produced by mechanical and bioprosthetic valves on MA were different.
Collapse
Affiliation(s)
- Qinglong Meng
- Department of Echocardiography, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Linyuan Wan
- Department of Echocardiography, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Fujian Duan
- Department of Anesthesiology, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Dandan Wang
- Clinical Research, Siemens Healthineers Ltd., Shanghai, China
| | - Jia Tao
- Department of Echocardiography, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Hao Wang
- Department of Echocardiography, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
| |
Collapse
|
2
|
Zamper R, Prempeh A, Iglesias I, Fayad A. Intraoperative transesophageal echocardiography following mitral valve repair: a systematic review. BRAZILIAN JOURNAL OF ANESTHESIOLOGY (ELSEVIER) 2022; 72:379-397. [PMID: 35301024 PMCID: PMC9373268 DOI: 10.1016/j.bjane.2022.03.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/21/2021] [Revised: 03/07/2022] [Accepted: 03/07/2022] [Indexed: 11/27/2022]
Abstract
OBJECTIVE We aimed to examine the recent evidence and search for novel assessments on intraoperative TEE following mitral valve repair that can impact short and long-term outcomes. METHODS The Ovid MEDLINE, PubMed, and EMBASE databases were searched from January 1, 2008, until January 27, 2021, for studies on patients with severe Mitral Valve Regurgitation (MR) undergoing Mitral Valve (MV) repair surgery with intraoperative Transesophageal Echocardiography (TEE) performed after the repair. Additional searches were conducted using Google search engine, Web of Science, and Cochrane Library. RESULTS After reviewing 302 records, 8 retrospective and 22 prospective studies were included (n = 30). Due to clinical and methodological diversity, these studies are noncomparable and data were not amenable to quantitative synthesis. CONCLUSION Although technological advances allowed the objective assessment of geometric and dynamic alterations of the MV, the impact of the use of these technologies on short- or long-term outcomes was not studied. There is uncertainty and conflicting evidence on the ideal method and metrics to evaluate MV patency post-repair. Few isolated studies validated methods to assess coaptation surface and LV function post-repair.
Collapse
Affiliation(s)
- Raffael Zamper
- Western University, Schulich School of Medicine and Dentistry, Department of Anesthesia and Perioperative Medicine, London, Canada.
| | - Agya Prempeh
- Western University, Schulich School of Medicine and Dentistry, Department of Anesthesia and Perioperative Medicine, London, Canada
| | - Ivan Iglesias
- Western University, Schulich School of Medicine and Dentistry, Department of Anesthesia and Perioperative Medicine, London, Canada
| | - Ashraf Fayad
- Western University, Schulich School of Medicine and Dentistry, Department of Anesthesia and Perioperative Medicine, London, Canada
| |
Collapse
|
3
|
Lawrie GM. Time to rest on our laurels or escape our bed of thorns? JTCVS OPEN 2021; 8:299. [PMID: 36004167 PMCID: PMC9390133 DOI: 10.1016/j.xjon.2021.07.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Affiliation(s)
- Gerald M Lawrie
- Department of Cardiovascular Surgery, Houston Methodist DeBakey Heart & Vascular Center, Houston, Tex
| |
Collapse
|
4
|
Lawrie G, Zoghbi W, Little S, Shah D, Earle N, Earle E. One Hundred Percent Reparability of Mitral Prolapse: Results of a Dynamic Nonresectional Technique. Ann Thorac Surg 2021; 112:1921-1928. [PMID: 33497666 DOI: 10.1016/j.athoracsur.2020.09.090] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/16/2020] [Revised: 09/10/2020] [Accepted: 09/28/2020] [Indexed: 11/16/2022]
Abstract
BACKGROUND We studied the results of a dynamic mitral repair technique that preserves normal mitral valve function by avoiding leaflet resection and rigid and semirigid annuloplasty rings. METHODS In previous reports we demonstrated that intraoperative simulation of mitral valve locking and isovolumic systole by rapid left ventricular inflation with pressurized saline accurately simulates mitral annular and leaflet shape and position, and left ventricular outflow tract dimensions. Length of polytetrafluoroethylene neochordae and size of fully flexible adjustable annuloplasty ring can be adjusted in three dimensions for accurate apposition of zones of leaflet coaptation, premarked with dots. We followed 1068 consecutive patients after repairs performed between 2001 and 2018. RESULTS Of the 1068 patients, 674 were men (63.1%). Mean age was 62.25 ± 13 years. Leaflet repaired was anterior in 118 patients (11.05%), posterior in 564 (52.81%), both in 55 (5.15%), and neither in 123 (11.5%). Barlow's disease was present in 208 patients (19.48%). Repair was isolated in 82.5% (881 of 1068). Reparability was 100%. Perioperative mortality overall was 1.59% (17 of 1068): isolated repair, 1.14% (10 of 881); and isolated posterior leaflet, 0.85% (4 of 472). Leaflet systolic anterior motion occurred in 1.7% (18 of 1068), and was significant in 0.4% (4 of 1068). Survival at 10 years by Kaplan-Meier analysis was 74.65%, freedom from reoperation was 96.01%, and freedom from severe mitral regurgitation was 94%. The only predictor of reoperation (Cox analysis) was being male (P = .001). CONCLUSIONS Use of intraoperative simulation of mitral dynamics led to 100% reparability for degenerative valves with minimal systolic anterior motion, despite no leaflet resection. Long-term durability has been good and similar for all leaflets.
Collapse
Affiliation(s)
- Gerald Lawrie
- Department of Cardiovascular Surgery, Methodist DeBakey Heart Center, Houston Methodist Hospital, Houston, Texas.
| | - William Zoghbi
- Department of Cardiology, Methodist DeBakey Heart Center, Houston Methodist Hospital, Houston, Texas
| | - Stephen Little
- Department of Cardiology, Methodist DeBakey Heart Center, Houston Methodist Hospital, Houston, Texas
| | - Dipan Shah
- Department of Cardiology, Methodist DeBakey Heart Center, Houston Methodist Hospital, Houston, Texas
| | - Nan Earle
- Department of Cardiovascular Surgery, Methodist DeBakey Heart Center, Houston Methodist Hospital, Houston, Texas
| | - Elizabeth Earle
- Department of Cardiovascular Surgery, Methodist DeBakey Heart Center, Houston Methodist Hospital, Houston, Texas
| |
Collapse
|
5
|
Surgical treatment of mitral regurgitation. Curr Opin Cardiol 2020; 35:491-499. [PMID: 32740446 DOI: 10.1097/hco.0000000000000772] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
PURPOSE OF REVIEW Mitral repair is the best treatment for degenerative mitral regurgitation. Many patients are referred too late for optimal outcomes. The US repair vs. replacement rate is only 60-80%, at a time when the inferiority of replacement has been established. Therefore, widely used traditional techniques of repair are being reappraised. RECENT FINDINGS Identification of risk factors predictive of poor early and late outcome have improved timing for surgical referral. Composite risk scores have been developed. Novel echocardiographic, cardiac MRI, and molecular level risk factors could improve timing. Analysis of factors contributing to low repair rates is also of critical importance. The role of institutional and surgeon volumes have been identified. More detailed data on the importance of dynamic function of the mitral valve have led to improved repair techniques such as intraoperative simulation of end diastole and early systole, use of expanded polytetrafluoroethylene neochords instead of leaflet resection, and dynamic instead of rigid annuloplasty. SUMMARY Our perception of mitral regurgitation has changed from a seemingly simple condition to one of considerable complexity at multiple levels. National guidelines should be studied and followed.
Collapse
|
6
|
Abdouni AA, Brandão CM, Rochitte CE, Pomerantzeff PM, Veronese ET, Pacheco AB, Santis AS, Tarasoutchi F, Jatene FB. Cardiac Magnetic Resonance Analysis of Mitral Annular Dynamics after Mitral Valve Repair. Clinics (Sao Paulo) 2020; 75:e2428. [PMID: 33263628 PMCID: PMC7654962 DOI: 10.6061/clinics/2020/e2428] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/15/2020] [Accepted: 09/24/2020] [Indexed: 11/18/2022] Open
Abstract
OBJECTIVES The aim of this study was to analyze mitral annulus (MA) dynamics using cardiac magnetic resonance (CMR) in patients with degenerative mitral insufficiency who underwent mitral valve repair (MVR). METHODS Mitral valve imaging was performed by CMR in twenty-nine patients with degenerative mitral insufficiency who underwent MVR between July 2014 and August 2016, with quadrangular resection of the posterior leaflet without ring annuloplasty. They were prospectively followed up from the preoperative period up to 2 years postoperatively. RESULTS We observed a significant reduction in all measurements of the MA after surgery. The mean systolic circumference of the MA was reduced from 13.28±1.95 cm to 11.50±1.59 cm, and the diastolic circumference was reduced from 12.51±2.01 cm to 10.66±2.09 cm in the immediate postoperative period, measures that remained stable 2 years after MVR (p<0.001). The mean maximum area of the MA was significantly reduced from 14.34±4.03 to 10.45±3.17 cm2 when comparing the immediate postoperative period and the 2 year follow-up (p<0.001). The same occurred with the mean minimum area of the MA, which was reduced from 12.53±3.68 cm2 to 9.23±2.84 cm2 in the same period, and this reduction was greater in the antero-posterior diameter than in the mid-lateral diameter. The mobility of the MA was preserved after surgery, ranging between 19.6% and 25.7% at 2-year follow-up. CONCLUSION We observed a significant reduction in the MA size after MVR, with preservation of the MA mobility at the 2-year follow-up.
Collapse
Affiliation(s)
- Ahmad A. Abdouni
- Instituto do Coracao (InCor), Hospital das Cinicas (HCFMUSP), Faculdade de Medicina, Universidade de Sao Paulo, Sao Paulo, SP, BR
- *Corresponding Author. E-mail:
| | - Carlos M.A. Brandão
- Instituto do Coracao (InCor), Hospital das Cinicas (HCFMUSP), Faculdade de Medicina, Universidade de Sao Paulo, Sao Paulo, SP, BR
| | - Carlos E. Rochitte
- Instituto do Coracao (InCor), Hospital das Cinicas (HCFMUSP), Faculdade de Medicina, Universidade de Sao Paulo, Sao Paulo, SP, BR
| | - Pablo M.A. Pomerantzeff
- Instituto do Coracao (InCor), Hospital das Cinicas (HCFMUSP), Faculdade de Medicina, Universidade de Sao Paulo, Sao Paulo, SP, BR
| | - Elinthon T. Veronese
- Instituto do Coracao (InCor), Hospital das Cinicas (HCFMUSP), Faculdade de Medicina, Universidade de Sao Paulo, Sao Paulo, SP, BR
| | - Ariane B. Pacheco
- Instituto do Coracao (InCor), Hospital das Cinicas (HCFMUSP), Faculdade de Medicina, Universidade de Sao Paulo, Sao Paulo, SP, BR
| | - Antonio S. Santis
- Instituto do Coracao (InCor), Hospital das Cinicas (HCFMUSP), Faculdade de Medicina, Universidade de Sao Paulo, Sao Paulo, SP, BR
| | - Flávio Tarasoutchi
- Instituto do Coracao (InCor), Hospital das Cinicas (HCFMUSP), Faculdade de Medicina, Universidade de Sao Paulo, Sao Paulo, SP, BR
| | - Fábio B. Jatene
- Instituto do Coracao (InCor), Hospital das Cinicas (HCFMUSP), Faculdade de Medicina, Universidade de Sao Paulo, Sao Paulo, SP, BR
| |
Collapse
|
7
|
Lang RM, Addetia K, Narang A, Mor-Avi V. 3-Dimensional Echocardiography: Latest Developments and Future Directions. JACC Cardiovasc Imaging 2019; 11:1854-1878. [PMID: 30522687 DOI: 10.1016/j.jcmg.2018.06.024] [Citation(s) in RCA: 52] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/27/2018] [Revised: 05/31/2018] [Accepted: 06/22/2018] [Indexed: 01/03/2023]
Abstract
The ongoing refinements in 3-dimensional (3D) echocardiography technology continue to expand the scope of this imaging modality in clinical cardiology by offering new features that stem from the ability to image the heart in its complete dimensionality. Over the years, countless publications have described these benefits and tested new frontiers where 3D echocardiographic imaging seemed to offer promising ways to improve patients' care. These include improved techniques for chamber quantification and novel ways to visualize cardiac valves, including 3D printing, virtual reality, and holography. The aims of this review article are to focus on the most important developments in the field in the recent years, discuss the current utility of 3D echocardiography, and highlight several interesting future directions.
Collapse
Affiliation(s)
- Roberto M Lang
- Department of Medicine, University of Chicago Medical Center, Chicago, Illinois.
| | - Karima Addetia
- Department of Medicine, University of Chicago Medical Center, Chicago, Illinois
| | - Akhil Narang
- Department of Medicine, University of Chicago Medical Center, Chicago, Illinois
| | - Victor Mor-Avi
- Department of Medicine, University of Chicago Medical Center, Chicago, Illinois
| |
Collapse
|
8
|
Bouchez S, Mackensen GB, Mauermann E, McCleish L, Cobey F, Swaminathan M, Wouters P. Differences in Two- and Three-Dimensional Assessment of the Mitral Valve by Novices and Experts, Illustrated Using Anterior Mitral Valve Leaflet Length. J Cardiothorac Vasc Anesth 2018; 33:1022-1028. [PMID: 30448072 DOI: 10.1053/j.jvca.2018.07.001] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/02/2018] [Indexed: 12/30/2022]
Abstract
OBJECTIVES In this measurement validation study, the authors evaluated agreement between 2-dimensional (2D) and three-dimensional (3D) transesophageal echocardiography (TEE), measuring anterior mitral valve leaflet length by both novice and experienced echocardiographers. DESIGN This was a retrospective, observational study. SETTING Single university hospital. PARTICIPANTS Analyses on datasets from 44 patients. INTERVENTIONS None. MEASUREMENTS AND MAIN RESULTS Fifty datasets from 44 patients with mitral regurgitation were analyzed by 4 observers (2 novices, 2 experts). All observers measured the anterior mitral valve leaflet length from end-systolic 2D TEE images from the midesophageal longitudinal axis view and 3D software-augmented TEE images. The overall mean anterior mitral valve leaflet length was significantly shorter with 3D versus 2D TEE measurements (24.6 ± 4.5 mm v 26.2 ± 5.3 mm; p < 0.001), with novices measuring shorter leaflets than experts for both techniques (p < 0.001 and p = 0.005, respectively). Bland-Altman plots of 3D and 2D TEE measurements showed mean biases (95% limits of agreement) of -1.6 mm (-9.0 to 5.9 mm), -1.8 mm (-9.6 to 6.0 mm), and -1.3 mm (-8.4 to 5.7 mm) for all observers, novices, and experts, respectively. For 2D measurements, interobserver reliability was very strong among experts and strong among novices (Pearson's r = 0.83 v 0.66; p = 0.055). For 3D measurements, interobserver reliability was strong in experts and moderate in novices (Pearson's r = 0.69 v 0.51; p = 0.168). CONCLUSION For both novices and experts, 3D TEE measurements of the anterior mitral valve leaflet were significantly shorter than 2D measurements. Interobserver reliability was lowest for novices making 3D TEE measurements, indicating that reliable, quantitative evaluation of 3D TEE may require a greater amount of practice.
Collapse
Affiliation(s)
- Stefaan Bouchez
- Department of Anesthesiology, Ghent University Hospital, Ghent, Belgium.
| | - G Burkhard Mackensen
- Department of Anesthesiology and Pain Medicine, University of Washington, Seattle, WA
| | - Eckhard Mauermann
- Department of Anesthesiology, Ghent University Hospital, Ghent, Belgium; Department for Anesthesia, Surgical Intensive Care, Prehospital Emergency Medicine and Pain Therapy, Basel University Hospital, Basel, Switzerland
| | - Linda McCleish
- Department of Anesthesiology, Sentara Heart Hospital, Norfolk, VA
| | - Frederick Cobey
- Department of Anesthesiology and Preoperative Medicine, Tufts Medical Center, Boston, MA
| | - Madhav Swaminathan
- Department of Anesthesiology, Duke University Medical Center, Durham, NC
| | - Patrick Wouters
- Department of Anesthesiology, Ghent University Hospital, Ghent, Belgium
| |
Collapse
|
9
|
Antoine C, Mantovani F, Benfari G, Mankad SV, Maalouf JF, Michelena HI, Enriquez-Sarano M. Pathophysiology of Degenerative Mitral Regurgitation. Circ Cardiovasc Imaging 2018; 11:e005971. [DOI: 10.1161/circimaging.116.005971] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Affiliation(s)
- Clemence Antoine
- From the Division of Cardiovascular Diseases and Internal Medicine, Mayo Clinic, Rochester, MN (C.A., F.M., G.B., S.V.M., J.F.M., H.I.M., M.E.-S.); and Arcispedale Santa Maria Nuova - IRCCS, Reggio Emilia, Italy (F.M.)
| | - Francesca Mantovani
- From the Division of Cardiovascular Diseases and Internal Medicine, Mayo Clinic, Rochester, MN (C.A., F.M., G.B., S.V.M., J.F.M., H.I.M., M.E.-S.); and Arcispedale Santa Maria Nuova - IRCCS, Reggio Emilia, Italy (F.M.)
| | - Giovanni Benfari
- From the Division of Cardiovascular Diseases and Internal Medicine, Mayo Clinic, Rochester, MN (C.A., F.M., G.B., S.V.M., J.F.M., H.I.M., M.E.-S.); and Arcispedale Santa Maria Nuova - IRCCS, Reggio Emilia, Italy (F.M.)
| | - Sunil V. Mankad
- From the Division of Cardiovascular Diseases and Internal Medicine, Mayo Clinic, Rochester, MN (C.A., F.M., G.B., S.V.M., J.F.M., H.I.M., M.E.-S.); and Arcispedale Santa Maria Nuova - IRCCS, Reggio Emilia, Italy (F.M.)
| | - Joseph F. Maalouf
- From the Division of Cardiovascular Diseases and Internal Medicine, Mayo Clinic, Rochester, MN (C.A., F.M., G.B., S.V.M., J.F.M., H.I.M., M.E.-S.); and Arcispedale Santa Maria Nuova - IRCCS, Reggio Emilia, Italy (F.M.)
| | - Hector I. Michelena
- From the Division of Cardiovascular Diseases and Internal Medicine, Mayo Clinic, Rochester, MN (C.A., F.M., G.B., S.V.M., J.F.M., H.I.M., M.E.-S.); and Arcispedale Santa Maria Nuova - IRCCS, Reggio Emilia, Italy (F.M.)
| | - Maurice Enriquez-Sarano
- From the Division of Cardiovascular Diseases and Internal Medicine, Mayo Clinic, Rochester, MN (C.A., F.M., G.B., S.V.M., J.F.M., H.I.M., M.E.-S.); and Arcispedale Santa Maria Nuova - IRCCS, Reggio Emilia, Italy (F.M.)
| |
Collapse
|
10
|
van Wijngaarden SE, Kamperidis V, Regeer MV, Palmen M, Schalij MJ, Klautz RJ, Bax JJ, Ajmone Marsan N, Delgado V. Three-dimensional assessment of mitral valve annulus dynamics and impact on quantification of mitral regurgitation. Eur Heart J Cardiovasc Imaging 2017; 19:176-184. [DOI: 10.1093/ehjci/jex001] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/10/2016] [Accepted: 01/06/2017] [Indexed: 11/13/2022] Open
|