Pace WA, Smith K, Gamboa A, Zamirpour S, Ge L, Tseng E. Ascending thoracic aortic aneurysm size at presentation and growth by diameter.
Clin Radiol 2023;
78:e1057-e1064. [PMID:
37833143 DOI:
10.1016/j.crad.2023.08.026]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2023] [Accepted: 08/31/2023] [Indexed: 10/15/2023]
Abstract
AIM
To investigate the hypothesis that lung cancer screening allows for earlier identification of ascending thoracic aortic aneurysms (aTAAs) and that growth rates for aTAAs are greatest at larger sizes.
MATERIALS AND METHODS
This single referral centre retrospective study manually gathered computed tomography (CT) data from 732 patients presenting from July 2002 to August 2022. Five hundred and seventeen patients with aTAA >39 mm were identified to compare presenting diameter by year of presentation. Four hundred and thirty-two patients had CT examinations >3 months apart, allowing for growth analysis. Patients were separated by initial examination date (before or after 12/31/2013) for presenting size comparison. Patients were then divided into five groups based on aTAA diameter for growth rate analysis.
RESULTS
At identification, patients had a median aTAA diameter of 44 mm (IQR 41-47 mm). Patients with aTAAs identified prior to December 2013 (n=129) had an average aTAA diameter 1.7 mm larger than those identified later (n=388; p=0.003). The growth analysis showed an average growth rate of 0.1 mm/year (p<0.001) across the entire cohort. Patients with an aTAA diameter of ≥55 mm (n=12) grew the fastest at 1.9 mm/year (p<0.001). In the <40 mm group (n=43), the aTAAs expanded at 0.2 mm/year, faster than the 0.1 mm/year of the slowest expanding 45-49 mm group (n=130; p=0.04).
CONCLUSION
aTAA size at discovery was larger before lung cancer screening guidelines took effect in December 2013. The largest aTAAs expanded fastest, but growth rates were slowest in the medium-sized 45-49 mm diameter group.
Collapse