1
|
D'Antò V, Oliva G, Rongo R, Bucci R, Martina S, Franchi L, Valletta R. Morphologic predictors of mandibular changes induced by Sander's Bite Jumping Appliance. Orthod Craniofac Res 2024. [PMID: 39180251 DOI: 10.1111/ocr.12850] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2024] [Revised: 07/19/2024] [Accepted: 08/12/2024] [Indexed: 08/26/2024]
Abstract
AIM This study aimed to identify pretreatment cephalometric variables as possible predictors of the mandibular length increase in Class II patients with mandibular retrusion, treated by means of the Bite Jumping Appliance (BJA). MATERIALS AND METHODS Forty-three subjects (22 males and 21 females) with Class II malocclusion, treated with a BJA, were selected on the basis of the following inclusion criteria: full Class II molar relationship, Overjet (OVJ) ≥ 6 mm and a skeletal Class II malocclusion with mandibular retrusion at the start of the treatment (T0); cervical vertebral maturation stage 2 or 3 at time 0 (T0). The following mandibular structural features were measured on lateral cephalograms at time 0 and time 1 (15 months of treatment): the width and height of the mandibular symphysis and its width/height ratio, the width and height of the mandibular ramus and its width/height ratio, the antegonial notch depth and the Condilion-Gonion-Menton (Co-Go-Me) angle. Post-treatment changes were assessed by Pancherz's cephalometric analysis, evaluating the increases in mandibular length. A regression statistical model was used to test the association between morphologic variables and mandibular length changes. RESULTS At T1, a significant increase in mandibular length (7.1 + 3.4 mm, p < .001) was measured. A significant negative association between the pretreatment Co-Go-Me angle and mandibular length change was found (p < .05). IMPA angle was negatively associated with mandibular length change. All the others morphological feature were not statistically related to mandibular length change. CONCLUSION Co-Go-Me angle and IMPA angle at T0 can be used as predictors for mandibular response to the treatment with BJA.
Collapse
Affiliation(s)
- Vincenzo D'Antò
- Department of Neuroscience, Reproductive Sciences and Oral Sciences, Section of Orthodontics, University of Naples Federico II, Naples, Italy
| | - Giorgio Oliva
- Department of Neuroscience, Reproductive Sciences and Oral Sciences, Section of Orthodontics, University of Naples Federico II, Naples, Italy
| | - Roberto Rongo
- Department of Neuroscience, Reproductive Sciences and Oral Sciences, Section of Orthodontics, University of Naples Federico II, Naples, Italy
| | - Rosaria Bucci
- Department of Neuroscience, Reproductive Sciences and Oral Sciences, Section of Orthodontics, University of Naples Federico II, Naples, Italy
| | - Stefano Martina
- Department of Medicine and Surgery and Dentistry, University of Salerno Scuola Medica Salernitana, Salerno, Italy
| | - Lorenzo Franchi
- Department of Experimental and Clinical Medicine, University of Florence Careggi, Florence, Italy
| | - Rosa Valletta
- Department of Neuroscience, Reproductive Sciences and Oral Sciences, Section of Orthodontics, University of Naples Federico II, Naples, Italy
| |
Collapse
|
2
|
Sambale J, Jablonski-Momeni A, Korbmacher-Steiner HM. Impact of initial lip competence on the outcome of class II functional appliances therapy. Clin Oral Investig 2024; 28:126. [PMID: 38286891 PMCID: PMC10824814 DOI: 10.1007/s00784-024-05511-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2023] [Accepted: 01/15/2024] [Indexed: 01/31/2024]
Abstract
OBJECTIVES The aim of this prospective clinical study was to evaluate the impact of initial lip position on class II functional appliance therapy. MATERIALS AND METHODS In total, 34 class II division 1 patients (23 females, 19 males; mean age 12.4 ± 0.9 years) that met the inclusion criteria (> ½ class II molar relationship, overjet > 6 mm, ANB > 4°, neutral or horizontal growth pattern, cervical vertebral maturation stage (CVMS) II - III, mean wear-time > 10 h/day) were consecutively divided into two groups (lip incompetence (LI); lip competence (LC)). All patients were treated with the Sander bite jumping appliance (BJA). Wear time was microelectronically measured. Lateral cephalograms were taken at the beginning (T0) and after 1 year of treatment (T1). An untreated class II group served as a control (CG). Inter-group comparisons were determined with Mann-Whitney U tests for independent samples. RESULTS Significant skeletal treatment effects were found in both treated groups when compared to the CG with significantly more pronounced mandibular skeletal effects in the LI than in the LC group (mandibular base length p < 0.001, composite mandibular base length p < 0.001, condylar head growth p = 0.002, co-pg p < 0.00, go-pg p = 0.003, reduction of the ANB angle p = 0.009, and Wits appraisal p < 0.001). CONCLUSION The more pronounced mandibular effects in the LI group were composed of the functional orthopedic effect plus harmonization of the lip competence. CLINICAL RELEVANCE Functional harmonization of lip incompetence with BJA enhances mandibular growth stimulation. Lip incompetence seems to impede mandibular growth and its harmonization seems to be a preventive approach.
Collapse
Affiliation(s)
- Janine Sambale
- Department of Orthodontics, Clinic of Dentistry, Philipps-University Marburg, Georg-Voigt-Str. 3, 35039, Marburg, Germany.
| | - Anahita Jablonski-Momeni
- Department of Orthodontics, Clinic of Dentistry, Philipps-University Marburg, Georg-Voigt-Str. 3, 35039, Marburg, Germany
| | - Heike Maria Korbmacher-Steiner
- Department of Orthodontics, Clinic of Dentistry, Philipps-University Marburg, Georg-Voigt-Str. 3, 35039, Marburg, Germany
| |
Collapse
|
3
|
Wafaie K, Mohammed H, Xinrui W, Zhou J, El Sergani AM, Yiqiang Q. Compliance with retainer wear using audiovisual integration and reminder: a randomized clinical trial. Sci Rep 2023; 13:8543. [PMID: 37237095 DOI: 10.1038/s41598-023-35686-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2023] [Accepted: 05/22/2023] [Indexed: 05/28/2023] Open
Abstract
Active audiovisual representation of instructions ensures vibrant knowledge acquisition and improves acquaintance needed for self-care with retainer wear. The aim of this trial is to assess the impact of audiovisual instructions with additional weekly electronic reminder messages on improving adherence to instructed wear time of Hawley retainer, periodontal outcomes, and participants' experiences. Fifty-two participants (mean age 26.1 y) planned for removable retention, were randomly assigned to two parallel groups to receive either (1) audiovisual instructions with an additional weekly reminder, or (2) verbal instructions alone. Each participant received a Hawley retainer equipped with a TheraMon microsensor and was instructed to wear it for 22 h daily. Participants were monitored for adherence to the wear time after 3 (T1) and 6 months (T2), and had their periodontal health and experiences assessed at T2. Overall, the mean objectively measured daily wear time at T1 was 14.9 (± 4.9 h), and 14.3 (± 5.4 h) at T2. After 3 months, no significant differences were found between the groups (p = 0.065), however, a significant difference favoring better compliance with wear instructions was observed in the audiovisual group after 6 months (p = 0.033). A non-significant difference was observed between both groups regarding the gingival (p = 0.165) and plaque index scores (p = 0.173). Participants' experiences were similar in both groups, except for satisfaction with the way of delivering instructions, being favorably reported in the audiovisual group. Audiovisual instructions with weekly reminders seem to have a significant effect on patient compliance in the longer term.Trial registration: TCTR20230220002.
Collapse
Affiliation(s)
- Khaled Wafaie
- Department of Orthodontics, Faculty of Dentistry, First Affiliated Hospital of Zhengzhou University, No. 1 Jianshe East Road, Erqi District, Zhengzhou, Henan, China.
| | - Hisham Mohammed
- Department of Oral Sciences, Faculty of Dentistry, University of Otago, Dunedin, New Zealand
| | - Wang Xinrui
- Department of Orthodontics, Faculty of Dentistry, First Affiliated Hospital of Zhengzhou University, No. 1 Jianshe East Road, Erqi District, Zhengzhou, Henan, China
| | - Jinshu Zhou
- Department of Orthodontics, Faculty of Dentistry, First Affiliated Hospital of Zhengzhou University, No. 1 Jianshe East Road, Erqi District, Zhengzhou, Henan, China
| | - Ahmed M El Sergani
- Department of Oral and Craniofacial Sciences, University of Pittsburgh School of Dental Medicine, Pittsburgh, USA
| | - Qiao Yiqiang
- Department of Orthodontics, Faculty of Dentistry, First Affiliated Hospital of Zhengzhou University, No. 1 Jianshe East Road, Erqi District, Zhengzhou, Henan, China.
| |
Collapse
|
4
|
Accuracy of thermal microsensors embedded in orthodontic retainers of different material composition and thickness: An in vitro study. AUSTRALASIAN ORTHODONTIC JOURNAL 2023. [DOI: 10.2478/aoj-2023-0005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/11/2023]
Abstract
Abstract
Objectives: The present research aimed to assess the accuracy and precision of the TheraMon® microsensor embedded in different thicknesses of Hawley retainers (HR) for comparison with vacuum formed retainers (VFR).
Methods: Thirty microsensors contained within different thicknesses and composition of retainers were divided into three equal groups: Group A thick coverage HR (3 mm), Group B thin coverage HR (1 mm), and Group C VFR (1 mm). The microsensors were immersed in thermostatic water at a controlled temperature of 35°C, which corresponds to the average intra-oral temperature. After 1 week, data were gathered using the TheraMon® client software and analysed using ANOVA and Turkey’s HSD tests.
Results: All TheraMon® microsensors were functional and produced uninterrupted recordings during the 1-week test period. Thermal detection differed between the three removable retainer groups. A near accurate thermostatic water detection was noticed with the thin HR with a mean temperature of 34.81 ± 0.04°C, followed by VFR 34.77 ± 0.09°C, and finally the thick HR 34.73 ± 0.05°C (ANOVA p-value = 0.025). A between-group comparison showed a significant mean difference (MD) between the thin and thick HR groups (MD: 0.08, p-value = 0.01). However, there were no significant differences between VFR and neither the thick Hawley (MD: 0.04, p-value = 0.27) nor the thin Hawley group (MD: -0.03, p-value = 0.39).
Conclusion: A removable retainer’s variation in material thickness and composition could induce small but detectable changes in the precision of thermal detection by TheraMon® microsensors.
Collapse
|
5
|
Nahajowski M, Lis J, Sarul M. Orthodontic Compliance Assessment: A Systematic Review. Int Dent J 2022; 72:597-606. [PMID: 35961844 PMCID: PMC9485511 DOI: 10.1016/j.identj.2022.07.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2022] [Revised: 07/09/2022] [Accepted: 07/11/2022] [Indexed: 11/23/2022] Open
Abstract
OBJECTIVES The aim of this review was to determine whether the type of removable appliance, as well as the age and sex of the patient, may affect the extension or reduction of wear time by assessing the correlation between the mean actual and orthodontist-recommended wear times. METHODS Randomised case control trials, cohort studies, case series, observational studies, reviews, and retrospective analyses were identified. The quality of the studies was assessed using the Cochrane Collaboration Tool and modified Newcastle-Ottawa Scale. The electronic databases Embase, PubMed, Scopus, and Web of Science were reviewed, and 542 articles were obtained, of which 31 were qualified for qualitative synthesis. The data from 1674 participants were collected and a weighted average was determined for the mean wear time of each appliance. RESULTS Regardless of the type of extra- or intraoral appliances, mean wear time was shorter than recommended, although patients using intraoral appliances cooperated more. The best compliance was noted for Schwarz appliances (73.70%) and plate retainers (85%). There was no evidence of an influence of patients' age and sex on compliance during treatment. CONCLUSIONS The considerable inconsistency and imprecision of articles could affect the reliability of the results. Previous studies analysing the effectiveness of treatment with removable appliances based on an arbitrarily assumed average wear time need to be revised in order to verify the actual wear time with the use of microsensors.
Collapse
Affiliation(s)
- Marek Nahajowski
- Department of Integrated Dentistry, Wroclaw Medical University, Wroclaw, Poland.
| | - Joanna Lis
- Department of Orthodontics and Dentofacial Orthopedics, Wroclaw Medical University, Wroclaw, Poland
| | - Michał Sarul
- Department of Integrated Dentistry, Wroclaw Medical University, Wroclaw, Poland
| |
Collapse
|
6
|
Sonesson M, Naraghi S, Bondemark L. Cost analysis of two types of fixed maxillary retainers and a removable vacuum-formed maxillary retainer: a randomized controlled trial. Eur J Orthod 2022; 44:197-202. [PMID: 35021204 PMCID: PMC8965225 DOI: 10.1093/ejo/cjab080] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
BACKGROUND There has been an increased interest in conducting healthcare economic evaluations. Also, orthodontic treatments have gathered focus from an economic point of view, however orthodontic research seldom examines both clinical and economic outcomes. OBJECTIVE To evaluate and compare the costs of three retention methods: a bonded retainer to the maxillary four incisors, a bonded retainer to the maxillary four incisors and canines, and a removable vacuum-formed retainer (VFR) in the maxilla. The null hypothesis was that there was no difference in costs for the three types of retention methods. TRIAL DESIGN Three-arm, parallel group, single-centre, randomized controlled trial. MATERIALS AND METHODS Ninety adolescent patients, 54 girls and 36 boys, treated with fixed or removable retainers in the maxilla, were recruited to the study. The patients were randomized in blocks of 30, by an independent person, to one of three groups: bonded multistranded PentaOne (Masel Orthodontics) retainer 13-23, bonded multistranded PentaOne (Masel Orthodontics) retainer 12-22, and removable VFR. A cost analysis was made regarding chair time costs based on the costs per hour for the specialist in orthodontics, and material costs plus any eventual costs for repairs of the appliance. Changes in Little's irregularity index and in single contact point discrepancies (CPDs) were measured on digitalized three-dimensional study casts. Data were evaluated on an intention-to-treat basis. The analysis was performed at 2 years of retention. RESULTS No statistically significant difference in costs between the maxillary fixed retainers and the VFRs was found, however, the material and emergency costs were significantly higher for the VFR compared with the bonded retainers. All three retention methods showed equally effective retention capacity, and no statistically significant differences in irregularity or CPDs of the maxillary anterior teeth in the three groups was detected. LIMITATIONS It was a single-centre trial, and hence less generalizable. Costs depended on local factors, and consequently, cannot be directly transferred to other settings. CONCLUSIONS All three retention methods can be recommended when considering costs and retention capacity. TRIAL REGISTRATION NCT04616755.
Collapse
Affiliation(s)
- Mikael Sonesson
- Department of Orthodontics, Faculty of Odontology, Malmö University, Sweden
| | - Sasan Naraghi
- Department of Orthodontics, Faculty of Odontology, Malmö University, Sweden
- Orthodontic Clinic, Public Dental Health, Växjö, Sweden
| | - Lars Bondemark
- Department of Orthodontics, Faculty of Odontology, Malmö University, Sweden
| |
Collapse
|
7
|
İshakoğlu S, Çokakoğlu S. Evaluation of relapse with thermoplastic retainers equipped with microsensors. Angle Orthod 2022; 92:340-346. [PMID: 35076691 DOI: 10.2319/072221-578.1] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2021] [Accepted: 11/01/2021] [Indexed: 11/23/2022] Open
Abstract
OBJECTIVES To examine relapse with thermoplastic retainers equipped with microsensors 1 year after treatment. MATERIALS AND METHODS A total of 42 patients (29 females, 13 males) treated with four premolar extractions were included in this study. Thermoplastic appliances equipped with TheraMon microsensors (Handelsagentur Gschladt, Hargelsberg, Austria) were used to assess daily wear time (DWT), and the patients were monitored at 2-month intervals for a period of 12 months. At the end of the follow-up, the following two groups were formed based on the mean DWT: short wear time (SWT; <9 h/d) and long wear time (LWT; ≥9 h/d). Digital models were constructed before treatment (T0), at debonding (T1), and 6 months (T2) and 12 months (T3) after debonding. Little's Irregularity Index (LII) and the intercanine and intermolar widths, arch lengths, overjet, and overbite were calculated based on the digital models. Data were analyzed statistically. RESULTS Irregularity and overjet increased, whereas transverse measurements and arch lengths decreased with time in both groups. During the retention period, overbite decreased in the SWT group but increased in the LWT group. There were significant differences between groups only in mandibular irregularity. The LII values of the SWT group were significantly higher than those of the LWT group for the T1-T2 and T1-T3 time intervals (P < .05). CONCLUSIONS A mean DWT less than 9 hours/day was inadequate for controlling irregularity within clinically acceptable limits. A wear time of at least 9 h/d is recommended for the maintenance of mandibular anterior alignment.
Collapse
|