1
|
Bauer CAJ, Scheurer M, Bourauel C, Kretzer JP, Roser CJ, Lux CJ, Hodecker LD. Precision of slot widths and torque transmission of in-office 3D printed brackets : An in vitro study. J Orofac Orthop 2024; 85:327-339. [PMID: 36862188 PMCID: PMC11358261 DOI: 10.1007/s00056-023-00460-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2022] [Accepted: 12/29/2022] [Indexed: 03/03/2023]
Abstract
PURPOSE To investigate a novel in-office three-dimensionally (3D) printed polymer bracket regarding slot precision and torque transmission. METHODS Based on a 0.022″ bracket system, stereolithography was used to manufacture brackets (N = 30) from a high-performance polymer that met Medical Device Regulation (MDR) IIa requirements. Conventional metal and ceramic brackets were used for comparison. Slot precision was determined using calibrated plug gages. Torque transmission was measured after artificial aging. Palatal and vestibular crown torques were measured from 0 to 20° using titanium-molybdenum (T) and stainless steel (S) wires (0.019″ × 0.025″) in a biomechanical experimental setup. The Kruskal-Wallis test with post hoc test (Dunn-Bonferroni) was used for statistical analyses (significance level p < 0.05). RESULTS The slot sizes of all three bracket groups were within the tolerance range according to DIN 13996 (ceramic [C]: 0.581 ± 0.003 mm; metal [M]: 0.6 ± 0.005 mm; polymer [P]: 0.581 ± 0.010 mm). The maximum torque values of all bracket-arch combinations were above the clinically relevant range of 5-20 Nmm (PS: 30 ± 8.6 Nmm; PT: 27.8 ± 14.2 Nmm; CS: 24 ± 5.6 Nmm; CT: 19.9 ± 3.8 Nmm; MS: 21.4 ± 6.7 Nmm; MT: 16.7 ± 4.6 Nmm). CONCLUSIONS The novel, in-office manufactured polymer bracket showed comparable results to established bracket materials regarding slot precision and torque transmission. Given its high individualization possibilities as well as enabling an entire in-house supply chain, the novel polymer brackets bear high potential of future usage for orthodontic appliances.
Collapse
Affiliation(s)
- Carolien A J Bauer
- Poliklinik für Kieferorthopädie, Universitätsklinikum Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany.
| | - Mats Scheurer
- Klinik und Poliklinik für Mund‑, Kiefer‑, Gesichtschirurgie, Universitätsklinikum Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
| | - Christoph Bourauel
- Oralmedizinische Technologie, Zentrum für Zahn‑, Mund- und Kieferheilkunde, Universitätsklinikum Bonn, Welschnonnenstr. 17, 53111, Bonn, Germany
| | - J Philippe Kretzer
- Labor für Biomechanik und Implantatforschung, Klinik für Orthopädie, Universitätsklinikum Heidelberg, Schlierbacher Landstraße 200a, 69118, Heidelberg, Germany
| | - Christoph J Roser
- Poliklinik für Kieferorthopädie, Universitätsklinikum Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
| | - Christopher J Lux
- Poliklinik für Kieferorthopädie, Universitätsklinikum Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
| | - Lutz D Hodecker
- Poliklinik für Kieferorthopädie, Universitätsklinikum Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
| |
Collapse
|
2
|
Dumbryte I, Narbutis D, Androulidaki M, Vailionis A, Juodkazis S, Malinauskas M. Teeth Microcracks Research: Towards Multi-Modal Imaging. Bioengineering (Basel) 2023; 10:1354. [PMID: 38135945 PMCID: PMC10740647 DOI: 10.3390/bioengineering10121354] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2023] [Revised: 11/16/2023] [Accepted: 11/21/2023] [Indexed: 12/24/2023] Open
Abstract
This perspective is an overview of the recent advances in teeth microcrack (MC) research, where there is a clear tendency towards a shift from two-dimensional (2D) to three-dimensional (3D) examination techniques, enhanced with artificial intelligence models for data processing and image acquisition. X-ray micro-computed tomography combined with machine learning allows 3D characterization of all spatially resolved cracks, despite the locations within the tooth in which they begin and extend, and the arrangement of MCs and their structural properties. With photoluminescence and micro-/nano-Raman spectroscopy, optical properties and chemical and elemental composition of the material can be evaluated, thus helping to assess the structural integrity of the tooth at the MC site. Approaching tooth samples having cracks from different perspectives and using complementary laboratory techniques, there is a natural progression from 3D to multi-modal imaging, where the volumetric (passive: dimensions) information of the tooth sample can be supplemented by dynamic (active: composition, interaction) image data. Revelation of tooth cracks clearly shows the need to re-assess the role of these MCs and their effect on the structural integrity and longevity of the tooth. This provides insight into the nature of cracks in natural hard materials and contributes to a better understanding of how bio-inspired structures could be designed to foresee crack propagation in biosolids.
Collapse
Affiliation(s)
- Irma Dumbryte
- Institute of Odontology, Vilnius University, LT-08217 Vilnius, Lithuania
| | - Donatas Narbutis
- Institute of Theoretical Physics and Astronomy, Vilnius University, LT-10222 Vilnius, Lithuania
| | - Maria Androulidaki
- Microelectronics Research Group, Institute of Electronic Structure & Laser, Foundation for Research and Technology FORTH-Hellas, 70013 Heraklion, Crete, Greece
| | - Arturas Vailionis
- Stanford Nano Shared Facilities, Stanford University, Stanford, CA 94305, USA
- Department of Physics, Kaunas University of Technology, LT-51368 Kaunas, Lithuania
| | - Saulius Juodkazis
- Optical Sciences Centre and ARC Training Centre in Surface Engineering for Advanced Materials (SEAM), School of Science, Swinburne University of Technology, Hawthorn, VIC 3122, Australia
- WRH Program International Research Frontiers Initiative (IRFI), Tokyo Institute of Technology, Nagatsuta-cho, Midori-ku, Yokohama 226-8503, Japan
| | | |
Collapse
|
3
|
Najjar YM, Burhan AS, Hajeer MY, Nawaya FR, Alam MK. Effects of the conventional, soft start, and pulse delay modes produced by light-emitting diode device on metal brackets bond strength and enamel damage: An in vitro comparative study. Int Orthod 2023; 21:100787. [PMID: 37393664 DOI: 10.1016/j.ortho.2023.100787] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2023] [Revised: 06/06/2023] [Accepted: 06/09/2023] [Indexed: 07/04/2023]
Abstract
OBJECTIVES This study aimed to compare the bond strength and enamel damage following debonding of metal brackets cured by different light-curing modes: conventional, soft start, and pulse delay modes. MATERIAL AND METHODS Sixty extracted upper premolars were randomly divided into three groups according to the used light-curing mode. Metal brackets were bonded with a light-emitting diode device employing different modes. Group 1: conventional mode (10s mesial+10 s distal); group 2: soft start mode (15s mesial+15s distal); group 3: pulse delay mode (3s mesial+3s distal, followed by 3min of no photoactivation, then 9s mesial+9s distal). Radiant exposure was the same in all study groups. Shear bond strengths of the brackets were tested with a universal testing machine. A stereomicroscope was used to determine the number and length of enamel microcracks. One-Way ANOVA and Kruskal-Wallis tests were used to detect significant differences in shear bond strength and microcracks number and length among groups. RESULTS The soft start and pulse delay modes produced significantly greater shear bond strength than the conventional mode (19.46±4.90MPa; 20.47±4.97MPa; 12.14±3.79MPa, respectively, P<0.001). However, there was no significant difference between the soft start and pulse delay groups (P=0.768). The number and length of microcracks increased significantly after debonding in all study groups. The change in microcracks length was not different among study groups. CONCLUSION The soft start and pulse delay modes produced greater bond strength than the conventional mode without predisposing enamel to higher risk of damage. Conservative methods for debonding are still required.
Collapse
Affiliation(s)
| | - Ahmad S Burhan
- Department of Pediatric Dentistry, Faculty of Dentistry, Syrian Private University, Damascus countryside, Syria
| | - Mohammad Y Hajeer
- Department of Orthodontics, University of Damascus Dental School, Damascus, Syria.
| | - Fehmieh R Nawaya
- Department of Pediatric Dentistry, Faculty of Dentistry, Syrian Private University, Damascus countryside, Syria
| | - Mohammad Khursheed Alam
- Orthodontic Unit, Preventive Dentistry Department, College of Dentistry, Jouf University, Sakaka 72345, Saudi Arabia
| |
Collapse
|
4
|
Solanki LA, Dinesh SS, Jain RK, Balasubramaniam A. Effects of titanium oxide coating on the antimicrobial properties, surface characteristics, and cytotoxicity of orthodontic brackets - A systematic review and meta analysis of in-vitro studies. J Oral Biol Craniofac Res 2023; 13:553-562. [PMID: 37409325 PMCID: PMC10319217 DOI: 10.1016/j.jobcr.2023.05.014] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2022] [Revised: 02/22/2023] [Accepted: 05/27/2023] [Indexed: 07/07/2023] Open
Abstract
Objective The objective of this review is to systematically analyze the available literature on the effects of titanium oxide (TiO₂) coating on the antimicrobial properties, surface characteristics, and cytotoxicity of orthodontic brackets. Methods In-vitro studies reporting on the effects of Titanium oxide (TiO₂) coatings on antimicrobial properties, surface roughness, cytotoxic activity and bacterial adhesion of orthodontic brackets were included in the review. Electronic databases such as PubMed, SCOPUS, Web of Science and Google Scholar, were searched till September 2022. Risk of Bias was analyzed by using RoBDEMAT tool. Meta-analysis using Random Effects Model was performed for assessing the antimicrobial activity against S. mutans, C. albicans and L. Acidophilus. Results A total of 11 studies were included the RoB analysis revealed sufficient reporting across all the domains and inconsistent reporting in only two of the domains. On qualitative analysis, a significant antimicrobial effect of TiO2 coating on orthodontic brackets against Streptococcus mutans, Candida albicans and Lactobacillus acidophilus was reported. The meta analysis revealed a significant overall antimicrobial effect with a high heterogeneity. (SMD: 3.5; p < 0.00001; i2 - 99.2%). Conclusion An overall significant antimicrobial effect of TiO₂ coated brackets against S. mutans, L. Acidophilus, C. Albicans was noted but with a high heterogeneity. The subgroup analysis revealed a significant antimicrobial effect on C albicans with a low heterogeneity but it was limited by a publication bias. The included studies reported reduced surface roughness, minimal bacterial adhesion and less cytotoxic activity with TiO₂ coated brackets than uncoated brackets.
Collapse
Affiliation(s)
- Lichi Ashwin Solanki
- Department of Orthodontics and Dentofacial Orthopaedics, Saveetha Dental College and Hospital, Saveetha Institute of Medical and Technical Sciences, Saveetha University, 162, Poonamallee High Road, Chennai, 600077, Tamil Nadu, India
| | - S.P. Saravana Dinesh
- Department of Orthodontics and Dentofacial Orthopaedics, Saveetha Dental College and Hospital, Saveetha Institute of Medical and Technical Sciences, Saveetha University, 162, Poonamallee High Road, Chennai, 600077, Tamil Nadu, India
| | - Ravindra Kumar Jain
- Department of Orthodontics and Dentofacial Orthopaedics, Saveetha Dental College and Hospital, Saveetha Institute of Medical and Technical Sciences, Saveetha University, 162, Poonamallee High Road, Chennai, 600077, Tamil Nadu, India
| | - Arthi Balasubramaniam
- Department of Public Health Dentistry, Saveetha Dental College and Hospital, Saveetha Institute of Medical and Technical Sciences, Saveetha University, 162, Poonamallee High Road, Chennai, 600077, Tamil Nadu, India
| |
Collapse
|
5
|
Hodecker LD, Scheurer M, Scharf S, Roser CJ, Fouda AM, Bourauel C, Lux CJ, Bauer CAJ. Influence of Individual Bracket Base Design on the Shear Bond Strength of In-Office 3D Printed Brackets-An In Vitro Study. J Funct Biomater 2023; 14:289. [PMID: 37367253 DOI: 10.3390/jfb14060289] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2023] [Revised: 05/19/2023] [Accepted: 05/22/2023] [Indexed: 06/28/2023] Open
Abstract
(1) Background: Novel high-performance polymers for medical 3D printing enable in-office manufacturing of fully customized brackets. Previous studies have investigated clinically relevant parameters such as manufacturing precision, torque transmission, and fracture stability. The aim of this study is to evaluate different design options of the bracket base concerning the adhesive bond between the bracket and tooth, measured as the shear bond strength (SBS) and maximum force (Fmax) according to DIN 13990. (2) Methods: Three different designs for printed bracket bases were compared with a conventional metal bracket (C). The following configurations were chosen for the base design: Matching of the base to the anatomy of the tooth surface, size of the cross-sectional area corresponding to the control group (C), and a micro- (A) and macro- (B) retentive design of the base surface. In addition, a group with a micro-retentive base (D) matched to the tooth surface and an increased size was studied. The groups were analyzed for SBS, Fmax, and adhesive remnant index (ARI). The Kruskal-Wallis test with a post hoc test (Dunn-Bonferroni) and Mann-Whitney U test were used for statistical analysis (significance level: p < 0.05). (3) Results: The values for SBS and Fmax were highest in C (SBS: 12.0 ± 3.8 MPa; Fmax: 115.7 ± 36.6 N). For the printed brackets, there were significant differences between A and B (A: SBS 8.8 ± 2.3 MPa, Fmax 84.7 ± 21.8 N; B: SBS 12.0 ± 2.1 MPa, Fmax 106.5 ± 20.7 N). Fmax was significantly different for A and D (D: Fmax 118.5 ± 22.8 N). The ARI score was highest for A and lowest for C. (4) Conclusions: This study shows that conventional brackets form a more stable bond with the tooth than the 3D-printed brackets. However, for successful clinical use, the shear bond strength of the printed brackets can be increased with a macro-retentive design and/or enlargement of the base.
Collapse
Affiliation(s)
- Lutz D Hodecker
- Department of Orthodontics and Dentofacial Orthopedics, University of Heidelberg, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany
| | - Mats Scheurer
- Department of Oral and Maxillofacial Surgery, University of Heidelberg, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany
| | - Sven Scharf
- Private Practice of Orthodontics, 50933 Cologne, Germany
| | - Christoph J Roser
- Department of Orthodontics and Dentofacial Orthopedics, University of Heidelberg, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany
| | - Ahmed M Fouda
- Oral Technology, Dental School, Medical Faculty, University Hospital of Bonn, Welschnonnenstr 17, 53111 Bonn, Germany
| | - Christoph Bourauel
- Oral Technology, Dental School, Medical Faculty, University Hospital of Bonn, Welschnonnenstr 17, 53111 Bonn, Germany
| | - Christopher J Lux
- Department of Orthodontics and Dentofacial Orthopedics, University of Heidelberg, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany
| | - Carolien A J Bauer
- Department of Orthodontics and Dentofacial Orthopedics, University of Heidelberg, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany
| |
Collapse
|
6
|
Nardi GM, Mazur M, Grassi R, Rifuggiato S, Stiuso V, Janiszewska-Olszowska J, Ottolenghi L, Barbato E, Minetola P, Iuliano L. Enamel Analysis by 3D Scanning after Three Orthodontic Clean-Up Procedures: An In-Vitro Test of a New Piezoelectric Tool. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2023; 20:2516. [PMID: 36767901 PMCID: PMC9915299 DOI: 10.3390/ijerph20032516] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/09/2023] [Revised: 01/19/2023] [Accepted: 01/29/2023] [Indexed: 06/18/2023]
Abstract
(1) Background: To assess the clinical safety and efficacy of a new piezoelectric instrument for orthodontic clean-up; (2) Methods: An in-vitro comparative study on 75 teeth extracted for orthodontic reasons compared the tested method (Treatment 1) with two other procedures: One step finisher and polisher (Inverted cone One gloss Shofu Dental, Kyoto, Japan) (Treatment 2) and twelve-fluted tungsten carbide bur (123-603-00, Dentaurum, Pforzheim, Germany) and Sof-Lex discs Pop-On XT Kit (3M ESPE) (Treatment 3), with n:25 samples in each group. Clinical safety (enamel volume loss) and effectiveness (residual adhesive volume) were assessed using the structured light 3D scanner Atos Compact Scan (GOM GmbH) together with the support of Atos Professional software. The surfaces were scanned three times to assess: (i) the volume of the residual adhesive (RAV) after bracket removal; (ii) the volume of the relative residual adhesive (dAV) after the clean-up procedure; (iii) volume of the enamel loss (EVL); (3) Results: The mean RAV (mm3) was 0.239 ± 0.337; 0.069 ± 0.124, 0.120 ± 0.193 and the mean EVL (mm3) was 0.1870 ± 0.177, 0.187 ± 0.299 and 0.290 ± 0.205, for treatment 1, 2 and 3, respectively. The distribution was asymmetrical between groups in both cases; (4) Conclusions: The tested instrument proved to be effective and safe for post-orthodontic clean-up. With the increasing use of invisible aligners, the possibility of using an ergonomic and fast instrument is of benefit to both patient and practitioner.
Collapse
Affiliation(s)
- Gianna Maria Nardi
- Department of Odontostomatological and Maxillofacial Sciences, Sapienza University of Rome, 00161 Rome, Italy
| | - Marta Mazur
- Department of Odontostomatological and Maxillofacial Sciences, Sapienza University of Rome, 00161 Rome, Italy
| | - Roberta Grassi
- Department of Oral Surgery, Tor Vergata University, 00100 Rome, Italy
| | - Serena Rifuggiato
- Department of Management and Production Engineering, Politecnico di Torino, 10129 Torino, Italy
| | - Vito Stiuso
- Department of Management and Production Engineering, Politecnico di Torino, 10129 Torino, Italy
| | | | - Livia Ottolenghi
- Department of Odontostomatological and Maxillofacial Sciences, Sapienza University of Rome, 00161 Rome, Italy
| | - Ersilia Barbato
- Department of Odontostomatological and Maxillofacial Sciences, Sapienza University of Rome, 00161 Rome, Italy
| | - Paolo Minetola
- Department of Management and Production Engineering, Politecnico di Torino, 10129 Torino, Italy
| | - Luca Iuliano
- Department of Management and Production Engineering, Politecnico di Torino, 10129 Torino, Italy
| |
Collapse
|
7
|
Dumbryte I, Narbutis D, Vailionis A, Juodkazis S, Malinauskas M. Revelation of microcracks as tooth structural element by X-ray tomography and machine learning. Sci Rep 2022; 12:22489. [PMID: 36577779 PMCID: PMC9797571 DOI: 10.1038/s41598-022-27062-5] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2022] [Accepted: 12/23/2022] [Indexed: 12/30/2022] Open
Abstract
Although teeth microcracks (MCs) have long been considered more of an aesthetic problem, their exact role in the structure of a tooth and impact on its functionality is still unknown. The aim of this study was to reveal the possibilities of an X-ray micro-computed tomography ([Formula: see text]CT) in combination with convolutional neural network (CNN) assisted voxel classification and volume segmentation for three-dimensional (3D) qualitative analysis of tooth microstructure and verify this approach with four extracted human premolars. Samples were scanned using a [Formula: see text]CT instrument (Xradia 520 Versa; ZEISS) and segmented with CNN to identify enamel, dentin, and cracks. A new CNN image segmentation model was trained based on "Multiclass semantic segmentation using DeepLabV3+" example and was implemented with "TensorFlow". The technique which was used allowed 3D characterization of all MCs of a tooth, regardless of the volume of the tooth in which they begin and extend, and the evaluation of the arrangement of cracks and their structural features. The proposed method revealed an intricate star-shaped network of MCs covering most of the inner tooth, and the main crack planes in all samples were arranged radially in two almost perpendicular directions, suggesting that the cracks could be considered as a planar structure.
Collapse
Affiliation(s)
- Irma Dumbryte
- grid.6441.70000 0001 2243 2806Institute of Odontology, Faculty of Medicine, Vilnius University, Vilnius, Lithuania
| | - Donatas Narbutis
- grid.6441.70000 0001 2243 2806Institute of Theoretical Physics and Astronomy, Faculty of Physics, Vilnius University, Vilnius, Lithuania
| | - Arturas Vailionis
- grid.168010.e0000000419368956Stanford Nano Shared Facilities, Stanford University, Stanford, USA ,grid.6901.e0000 0001 1091 4533Department of Physics, Kaunas University of Technology, Kaunas, Lithuania
| | - Saulius Juodkazis
- grid.1027.40000 0004 0409 2862Optical Sciences Centre and ARC Training Centre in Surface Engineering for Advanced Materials (SEAM), School of Science, Swinburne University of Technology, Hawthorn, Australia ,grid.32197.3e0000 0001 2179 2105WRH Program International Research Frontiers Initiative (IRFI) Tokyo Institute of Technology, Nagatsuta-cho, Midori-ku, Yokohama, Japan
| | - Mangirdas Malinauskas
- grid.6441.70000 0001 2243 2806Laser Research Center, Faculty of Physics, Vilnius University, Vilnius, Lithuania
| |
Collapse
|
8
|
Garma NMH, Ibrahim AI. Development of a remineralizing calcium phosphate nanoparticle-containing self-etching system for orthodontic bonding. Clin Oral Investig 2022; 27:1483-1497. [PMID: 36322155 PMCID: PMC10101901 DOI: 10.1007/s00784-022-04767-5] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2022] [Accepted: 10/26/2022] [Indexed: 01/02/2023]
Abstract
Abstract
Objectives
This study aimed to incorporate hydroxyapatite nanoparticles (nHA) or amorphous calcium phosphate nanoparticles (nACP) into a self-etch primer (SEP) to develop a simplified orthodontic bonding system with remineralizing and enamel preserving properties.
Materials and Methods
nHA and nACP were incorporated into a commercial SEP (Transbond™ plus) in 7% weight ratio and compared with the plain SEP as a control. Shear bond strengths (SBS), enamel damage, and adhesive remnant index (ARI) scores were evaluated at 24 h and post 5000 thermocycling. Field-emission scanning electron microscope (FESEM) was used to inspect the distribution of the nanoparticles in the experimental SEPs and evaluate the enamel surface integrity both before bracket bonding and post bracket debonding. Phase determination and remineralizing capability of the modified SEP were characterized by X-ray diffraction and Raman spectroscopy, respectively.
Results
The addition of nHA or nACP to the SEP significantly reduced the SBS, ARI, and enamel damage (p < 0.05) as compared to the control SEP; however, only nHA-SEP survived the thermocycling protocol and yielded acceptable SBS (13.38 MPa). Enamel remineralizing ability of the developed nHA-SEP was confirmed by both FESEM images and Raman phosphate map.
Conclusions
Incorporating nHA into SEP resulted in clinically acceptable bond strengths with remineralizing ability.
Clinical relevance
The newly developed nHA-SEP has unprecedented ability to simultaneously etch, prime, and remineralize the enamel in a single step leaving immaculate enamel surface with the potential of saving cost and time at the post-debonding step.
Collapse
Affiliation(s)
- Noor M. H. Garma
- Orthodontic Department, College of Dentistry, University of Baghdad, Bab Al-Moadham Campus, Floor 4, Baghdad, Iraq
| | - Ali I. Ibrahim
- Orthodontic Department, College of Dentistry, University of Baghdad, Bab Al-Moadham Campus, Floor 4, Baghdad, Iraq
- Centre for Oral, Clinical and Translational Sciences, Faculty of Dentistry, Oral & Craniofacial Sciences, King’s College London, London, UK
| |
Collapse
|
9
|
Effects of Three Novel Bracket Luting Agents Containing Zirconia Primer on Shear Bond Strength of Metal Orthodontic Brackets Attached to Monolithic Zirconia Crowns: A Preliminary In Vitro Study. Int J Dent 2022; 2022:7107526. [PMID: 35251182 PMCID: PMC8894071 DOI: 10.1155/2022/7107526] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2022] [Accepted: 02/01/2022] [Indexed: 11/18/2022] Open
Abstract
Background The increased use of zirconia crowns in adult orthodontic patients warrants the establishment of methods and materials to adhere orthodontic brackets properly to zirconia crowns. However, studies in this regard are scarce, and many materials remain untested. This preliminary study aimed to examine three new adhesives containing zirconia primers for the first time. Methods Sixty identical monolithic zirconia crowns were fabricated and randomly divided into 4 groups of 15 each (Panavia SA Cement Plus, G-CEM, TheraCem, and Transbond XT Composite (control)). After glaze removal with a diamond bur, a metal orthodontic bracket was attached to the surfaces of the crowns using the respective adhesive. Specimens were incubated at 37°C and then thermocycled for 2000 cycles. Shear bond strengths (SBS) of brackets in different groups were estimated using a universal testing machine. Mean SBS values were compared with the values 6, 8, and 10 (as acceptable SBS values) and 13 MPa (as the maximum SBS tolerable by zirconia) using the one-sample t-test. They were also compared with each other using the one-way ANOVA and Tamhane post hoc test (α = 0.05). Results The ANOVA indicated a significant overall difference; the Tamhane test showed that the difference between the control group and all test groups was significant (P < 0.0005); however, the 3 test groups were not significantly different from each other (P > 0.30). The SBS of the control group was significantly lower than the minimum acceptable SBS (6 MPa, P < 0.0005). The mean SBS of the TheraCem was not significantly different from 10 MPa (P = 0.902), while the mean SBS values of Panavia SA Cement Plus and G-CEM were significantly greater than 10 MPa (P < 0.05). None of the three zirconia adhesives had mean SBS values higher than 13 MPa. Conclusion All novel zirconia adhesives (Panavia SA Cement Plus, G-CEM, and TheraCem) generated SBS values adequate to attach metal orthodontic brackets to zirconia prostheses (at or greater than 10 MPa) without damaging the zirconia during bracket removal (not above 13 MPa).
Collapse
|
10
|
Dumbryte I, Vailionis A, Skliutas E, Juodkazis S, Malinauskas M. Three-dimensional non-destructive visualization of teeth enamel microcracks using X-ray micro-computed tomography. Sci Rep 2021; 11:14810. [PMID: 34285299 PMCID: PMC8292334 DOI: 10.1038/s41598-021-94303-4] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2021] [Accepted: 07/07/2021] [Indexed: 02/06/2023] Open
Abstract
Although the topic of tooth fractures has been extensively analyzed in the dental literature, there is still insufficient information about the potential effect of enamel microcracks (EMCs) on the underlying tooth structures. For a precise examination of the extent of the damage to the tooth structure in the area of EMCs, it is necessary to carry out their volumetric [(three-dimensional (3D)] evaluation. The aim of this study was to validate an X-ray micro-computed tomography ([Formula: see text]CT) as a technique suitable for 3D non-destructive visualization and qualitative analysis of teeth EMCs of different severity. Extracted human maxillary premolars were examined using a [Formula: see text]CT instrument ZEISS Xradia 520 Versa. In order to separate crack, dentin, and enamel volumes a Deep Learning (DL) algorithm, part of the Dragonfly's segmentation toolkit, was utilized. For segmentation needs we implemented Dragonfly's pre-built UNet neural network. The scanning technique which was used made it possible to recognize and detect not only EMCs that are visible on the outer surface but also those that are buried deep inside the tooth. The 3D visualization, combined with DL assisted segmentation, enabled the evaluation of the dynamics of an EMC and precise examination of its position with respect to the dentin-enamel junction.
Collapse
Affiliation(s)
| | - Arturas Vailionis
- Stanford Nano Shared Facilities, Stanford University, Stanford, USA
- Department of Physics, Kaunas University of Technology, Kaunas, Lithuania
| | - Edvinas Skliutas
- Laser Research Center, Faculty of Physics, Vilnius University, Vilnius, Lithuania
| | - Saulius Juodkazis
- Optical Sciences Centre and ARC Training Centre in Surface Engineering for Advanced Materials (SEAM), School of Science, Swinburne University of Technology, Hawthorn, Australia
- Tokyo Tech World Research Hub Initiative (WRHI), School of Materials and Chemical Technology, Tokyo Institute of Technology, Tokyo, Japan
| | - Mangirdas Malinauskas
- Laser Research Center, Faculty of Physics, Vilnius University, Vilnius, Lithuania
- Tokyo Tech World Research Hub Initiative (WRHI), School of Materials and Chemical Technology, Tokyo Institute of Technology, Tokyo, Japan
| |
Collapse
|
11
|
Tran L, Tam DNH, Elshafay A, Dang T, Hirayama K, Huy NT. Quality assessment tools used in systematic reviews of in vitro studies: A systematic review. BMC Med Res Methodol 2021; 21:101. [PMID: 33964880 PMCID: PMC8106836 DOI: 10.1186/s12874-021-01295-w] [Citation(s) in RCA: 43] [Impact Index Per Article: 14.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2020] [Accepted: 04/26/2021] [Indexed: 12/15/2022] Open
Abstract
BACKGROUND Systematic reviews (SRs) and meta-analyses (MAs) are commonly conducted to evaluate and summarize medical literature. This is especially useful in assessing in vitro studies for consistency. Our study aims to systematically review all available quality assessment (QA) tools employed on in vitro SRs/MAs. METHOD A search on four databases, including PubMed, Scopus, Virtual Health Library and Web of Science, was conducted from 2006 to 2020. The available SRs/MAs of in vitro studies were evaluated. DARE tool was applied to assess the risk of bias of included articles. Our protocol was developed and uploaded to ResearchGate in June 2016. RESULTS Our findings reported an increasing trend in publication of in vitro SRs/MAs from 2007 to 2020. Among the 244 included SRs/MAs, 126 articles (51.6%) had conducted the QA procedure. Overall, 51 QA tools were identified; 26 of them (51%) were developed by the authors specifically, whereas 25 (49%) were pre-constructed tools. SRs/MAs in dentistry frequently had their own QA tool developed by the authors, while SRs/MAs in other topics applied various QA tools. Many pre-structured tools in these in vitro SRs/MAs were modified from QA tools of in vivo or clinical trials, therefore, they had various criteria. CONCLUSION Many different QA tools currently exist in the literature; however, none cover all critical aspects of in vitro SRs/MAs. There is a need for a comprehensive guideline to ensure the quality of SR/MA due to their precise nature.
Collapse
Affiliation(s)
- Linh Tran
- Institute of Fundamental and Applied Sciences, Duy Tan University, Ho Chi Minh City, 700000, Vietnam
- Faculty of Natural Sciences, Duy Tan University, Da Nang City, 550000, Vietnam
| | - Dao Ngoc Hien Tam
- Asia Shine Trading & Service CO. LTD., Ho Chi Minh City, Vietnam
- Online Research Club, Nagasaki, Japan
| | - Abdelrahman Elshafay
- Online Research Club, Nagasaki, Japan
- Faculty of Medicine, Al-Azhar University, Cairo, 11884, Egypt
| | - Thao Dang
- Online Research Club, Nagasaki, Japan
- Department of Internal Medicine, Texas Tech University Health Science Center at the Permian Basin, Odessa, TX, USA
| | - Kenji Hirayama
- Department of Immunogenetics, Institute of Tropical Medicine (NEKKEN), Graduate School of Biomedical Sciences, Nagasaki University, 1-12-4 Sakamoto, Nagasaki, 852-8523, Japan
| | - Nguyen Tien Huy
- School of Tropical Medicine and Global Health, Nagasaki University, 1-12-4 Sakamoto, Nagasaki, 852-8523, Japan.
| |
Collapse
|
12
|
Dumbryte I, Malinauskas M. In vivo examination of enamel microcracks after orthodontic debonding: Is there a need for detailed analysis? Am J Orthod Dentofacial Orthop 2021; 159:e103-e111. [PMID: 33390312 DOI: 10.1016/j.ajodo.2020.09.013] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2020] [Revised: 08/01/2020] [Accepted: 09/01/2020] [Indexed: 10/22/2022]
Abstract
INTRODUCTION Our aim was to assess changes in the number of enamel microcracks (EMCs) after removing metal brackets in teeth with and without visible EMCs before the bonding procedure. METHODS Before bonding, 13 patients having teeth with visible EMCs and 13 subjects whose teeth were free of EMCs were included in the study. All patients were asked to complete a questionnaire with a detailed medical history at the beginning of treatment and after removing metal brackets. The number of teeth with visible EMCs and the number of premolars without EMCs were recorded for each subject twice, that is, before bonding and after debonding, together with the tooth sensitivity assessments elicited by compressed air and cold testing. RESULTS The number of visible EMCs in premolars increased after removing metal brackets. EMCs were recorded in at least 25.0% of all evaluated teeth for the patients having teeth with and without visible EMCs at the beginning of treatment. However, the changes in the number of visible EMCs were not significantly different (P = 0.619) between the groups. For the subjects with visible EMCs, tooth sensitivity caused by cold was registered nearly 3 times more often after removing brackets compared with the patients without EMCs prior bonding. CONCLUSIONS Formation of EMCs was noticed after debonding. Changes in the number appeared to be similar for the subjects with and without visible EMCs before bonding. Higher incidence of EMCs was associated with more frequent tooth sensitivity perceptions after removing brackets.
Collapse
Affiliation(s)
- Irma Dumbryte
- Institute of Odontology, Vilnius University, Vilnius, Lithuania.
| | | |
Collapse
|
13
|
Ferreira FG, da Silva EM, Vilella ODV. A Novel Method Using Confocal Laser Scanning Microscopy for Three-Dimensional Analysis of Human Dental Enamel Subjected to Ceramic Bracket Debonding. MICROSCOPY AND MICROANALYSIS : THE OFFICIAL JOURNAL OF MICROSCOPY SOCIETY OF AMERICA, MICROBEAM ANALYSIS SOCIETY, MICROSCOPICAL SOCIETY OF CANADA 2020; 26:1053-1060. [PMID: 32843117 DOI: 10.1017/s1431927620024319] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
The aim of this in vitro study was to present a method using confocal laser scanning microscopy for three-dimensional analysis of human dental enamel subjected to ceramic bracket debonding. The labial enamel surfaces of three upper central incisors were prepared and mounted in the form of standardized specimens. A sample repositioning protocol was established to enable surface measurement and analysis before and after bracket debonding. Observations were made of representative areas measuring 1,280 × 1,280 μm2, in the center of the enamel samples, as well as of the total topography (2,500 × 3,500 μm) of the bonding areas provided by the equipment software. Noncontact three-dimensional high-resolution image analyses revealed the capabilities of the employed technique and methodology to permit the examination of specific characteristics and alterations on the surfaces, before and after the debonding and finishing procedures. The new protocol was effective to provide qualitative and quantitative assessments of changes on the same dental surfaces at different trial times. The methodology constitutes a feasible tool for revealing the effects of debonding of ceramic brackets on sound and previously injured dental enamel surfaces.
Collapse
Affiliation(s)
- Fabiano G Ferreira
- Department of Orthodontics, School of Dentistry, Universidade Federal Fluminense, Niterói, Rio de Janeiro24020-140, Brazil
| | - Eduardo M da Silva
- Analitical Laboratory of Restorative Biomaterials - LABiom-R, School of Dentistry, Universidade Federal Fluminense, Niterói, Rio de Janeiro24020-140, Brazil
| | - Oswaldo de V Vilella
- Department of Orthodontics, School of Dentistry, Universidade Federal Fluminense, Niterói, Rio de Janeiro24020-140, Brazil
| |
Collapse
|
14
|
Evaluation of Enamel Topography after Debonding Orthodontic Ceramic Brackets by Different Er,Cr:YSGG and Er:YAG Lasers Settings. Dent J (Basel) 2020; 8:dj8010006. [PMID: 31936500 PMCID: PMC7175227 DOI: 10.3390/dj8010006] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2019] [Revised: 01/06/2020] [Accepted: 01/07/2020] [Indexed: 11/17/2022] Open
Abstract
In the last decade, the success of lasers in simplifying many dental procedures has heightened the need for research in the orthodontic field, in order to evaluate the benefits of laser-assisted ceramic brackets debonding. Conventional ceramic brackets removal delivers a high shear bond strength (SBS), which might lead to enamel damage. Nowadays, debonding ceramic brackets by Er:YAG laser seems a viable alternative technique; however, there is no data on the use of Er,Cr:YSGG in the literature. We aimed to evaluate the difference in enamel topography derived from different erbium laser settings used during debonding. One hundred and eighty bovine incisors teeth were randomly divided into fifteen experimental groups, according to different erbium laser settings using scanning methods. SBS testing was performed after debonding; stereomicroscopic and SEM analyses were done after cleaning the remaining adhesive so as to assess the incidence of enamel microcracks formation and enamel loss. There were no statistically significant differences between the proportions of teeth with normal enamel topography within the control group when compared with any of the Er:YAG groups. However, the proportion of teeth with a normal enamel topography in Er,Cr:YSGG was 4 W/20 Hz (83.3%) and in Er:YAG was 5 W/20 Hz (91.7%), which was statistically significantly higher than the control group (41.7%). The selection of erbium lasers' optimal parameters during debonding influences the enamel topography. When considering the evaluation of both microscopic and statistical analyses, irradiation by Er:YAG (120 mJ/40 Hz) displayed a significant reduction in microcracks compared with conventional debonding, even though some microstructural changes in the enamel could be noted. Er,Cr:YSGG (4 W/20 Hz) respected the enamel topography the most out of the studied groups.
Collapse
|
15
|
Hoteit M, Nammour S, Zeinoun T. Assessment of microcracks and shear bond strength after debonding orthodontic ceramic brackets on enamel priorly etched by different Er,Cr:YSGG and Er:YAG laser settings without acid application: An in vitro study. Int Orthod 2019; 17:744-757. [PMID: 31543426 DOI: 10.1016/j.ortho.2019.08.019] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
BACKGROUND DATA Enamel microcrack formation has a high incidence after mechanical debonding of ceramic brackets. This may be due to high delivered shear bond strength values when enamel is priorly etched by phosphoric acid. It is still not well elucidated in the literature if laser etching affects enamel the same way. The aim of the research was to analyze different Er,Cr:YSGG and Er:YAG laser etching settings as an alternative to phosphoric acid, in an attempt to prevent enamel microcrack formation during laser etching and mechanical debonding, while reducing the shear bond strength to the minimal clinical acceptable value. MATERIALS AND METHODS One hundred and thirty-three teeth were randomly divided into 7 experimental groups according to their etching modalities. Settings used for enamel etching were in Er,Cr:YSGG groups: Er,Cr:YSGG (1.5Watt, W/20Hertz, Hz); Er,Cr:YSGG (1.5W/15Hz) and Er,Cr:YSGG (2W/20Hz) and settings used for enamel etching in Er:YAG groups were: Er:YAG (60 millijoules, mJ), Er:YAG (80mJ) and Er:YAG (100mJ). Group C etched with 37% phosphoric acid served as control. Microscopic analysis was performed to assess presence of enamel microcracks. Shear bond strength was evaluated after thermocycling using Weibull survival analysis. RESULTS All groups showed a reduction in additional microcracks after debonding when compared to control, but only group Er:YAG (60mJ) exhibited a statistically significant difference. Groups Er:YAG (80mJ), control and Er:YAG (100mJ) showed respectively the highest probability of survival at various stress levels followed by groups Er:YAG (60mJ); Er,Cr:YSGG (1.5W/15Hz); Er,Cr:YSGG (2W/20Hz) and Er,Cr:YSGG (1.5W/20Hz) that presented a relatively considerable risk of failure, even at low stress levels. CONCLUSIONS When considering reduction of enamel microcrack formation and clinical acceptable shear bond strength, none of the groups succeeded both. Etching by Er:YAG (60mJ) and Er,Cr:YSGG (1.5W/15Hz), showed the least overall microcrack incidence between groups, but Er:YAG (60mJ) displayed significant reduction compared to phosphoric acid. However, etching by Er:YAG (80mJ) had the most predictable results in term of shear bond strength.
Collapse
Affiliation(s)
- Marwan Hoteit
- Lebanese University, Faculty of Dental Medicine, Department of Orthodontics, Hadath, Lebanon.
| | - Samir Nammour
- University of Liege, Faculty of Medicine, Department of Dental Science, 4020 Liege, Belgium
| | - Toni Zeinoun
- Lebanese University,Faculty of Dental Medicine, Department of Oral and Maxillofacial Surgery, Lebanon
| |
Collapse
|
16
|
Franz A, Raabe M, Lilaj B, Dauti R, Moritz A, Müßig D, Cvikl B. Effect of two different primers on the shear bond strength of metallic brackets to zirconia ceramic. BMC Oral Health 2019; 19:51. [PMID: 30922281 PMCID: PMC6437858 DOI: 10.1186/s12903-019-0740-6] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2018] [Accepted: 03/18/2019] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND In view of the increasing demand of adult orthodontics for esthetic purposes, adult treatment with brackets has become an important issue. One essential factor for the quality of such treatment is bracket bonding on ceramics. For testing the adhesive bond between the bracket and the ceramic surface it is important to consider the static or cyclic loading that goes along with it. METHODS Metallic Brackets were adhesively fixed on zirconia ceramic blocks in a simulated leveling phase using two different primers (Monobond S and Monobond Etch & Prime). Half of the metallic brackets were activated using a 0.14-nickel titanium wire, while the other half remained non-activated. Shear bond testing (SBT) was performed after thermocycling. Furthermore the Adhesive Remnant Index (ARI) was analyzed. RESULTS SBT resulted in significantly higher shear bond values when Monobond Etch & Prime was used compared to the use of Monobond S. Activation of the brackets did not show different results in comparison to the non-activated brackets. The ARI did not indicate cement remnants on the ceramic surface, regardless of the primer and the activation status. CONCLUSIONS The use of Monobond Etch & Prime has great potential for the bonding of brackets on dental zirconia ceramics.
Collapse
Affiliation(s)
- Alexander Franz
- Department of Conservative Dentistry and Periodontology, Medical University of Vienna, Sensengasse 2A, 1090, Vienna, Austria
| | | | - Bledar Lilaj
- Department of Conservative Dentistry and Periodontology, Medical University of Vienna, Sensengasse 2A, 1090, Vienna, Austria
| | - Rinet Dauti
- Department of Conservative Dentistry and Periodontology, Medical University of Vienna, Sensengasse 2A, 1090, Vienna, Austria
| | - Andreas Moritz
- Department of Conservative Dentistry and Periodontology, Medical University of Vienna, Sensengasse 2A, 1090, Vienna, Austria
| | - Dieter Müßig
- Centre for Orthodontics, Division of Dentistry, Danube Private University, Krems, Austria
| | - Barbara Cvikl
- Department of Conservative Dentistry and Periodontology, Medical University of Vienna, Sensengasse 2A, 1090, Vienna, Austria. .,Department of Conservative Dentistry, Sigmund Freud University, Vienna, Austria.
| |
Collapse
|