1
|
Salaun E, Drory S, Coté M, Tremblay V, Bédard E, Steinberg C, Paré D, O'Connor K, Cieza T, Coté N, Poirier P, Douville P, Blais J, Desmeules P, Kalavrouziotis D, Mohammadi S, Voisine P, Bernier M, Pibarot P, Thériault S. Role of Antitroponin Antibodies and Macrotroponin in the Clinical Interpretation of Cardiac Troponin. J Am Heart Assoc 2024; 13:e035128. [PMID: 38879450 PMCID: PMC11255741 DOI: 10.1161/jaha.123.035128] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 06/19/2024]
Abstract
Cardiac troponin is extensively used as a biomarker in modern medicine due to its diagnostic capability for myocardial injury, as well as its predictive and prognostic value for cardiac diseases. However, heterophile antibodies, antitroponin antibodies, and macrotroponin complexes can be observed both in seemingly healthy individuals and patients with cardiac diseases, potentially leading to false positive or disproportionate elevation of cTn (cardiac troponin) assay results and introducing discrepancies in clinical interpretations with impact on medical management. In this review article, we describe the possible mechanisms of cTn release and the sources of variations in the assessment of circulating cTn levels. We also explore the pathophysiological mechanisms underlying antitroponin antibody development and discuss the influence exerted by macrotroponin complexes on the results of immunoassays. Additionally, we explore approaches to detect these complexes by presenting various clinical scenarios encountered in routine clinical practice. Finally, unsolved questions about the development, prevalence, and clinical significance of cardiac autoantibodies are discussed.
Collapse
Affiliation(s)
- Erwan Salaun
- Institut Universitaire de Cardiologie et de Pneumologie de QuébecUniversité LavalQuébecCanada
| | - Samuel Drory
- Institut Universitaire de Cardiologie et de Pneumologie de QuébecUniversité LavalQuébecCanada
| | - Marc‐André Coté
- Institut Universitaire de Cardiologie et de Pneumologie de QuébecUniversité LavalQuébecCanada
| | - Veronic Tremblay
- Institut Universitaire de Cardiologie et de Pneumologie de QuébecUniversité LavalQuébecCanada
| | - Elisabeth Bédard
- Institut Universitaire de Cardiologie et de Pneumologie de QuébecUniversité LavalQuébecCanada
| | - Christian Steinberg
- Institut Universitaire de Cardiologie et de Pneumologie de QuébecUniversité LavalQuébecCanada
| | - David Paré
- Institut Universitaire de Cardiologie et de Pneumologie de QuébecUniversité LavalQuébecCanada
| | - Kim O'Connor
- Institut Universitaire de Cardiologie et de Pneumologie de QuébecUniversité LavalQuébecCanada
| | - Tomas Cieza
- Institut Universitaire de Cardiologie et de Pneumologie de QuébecUniversité LavalQuébecCanada
| | - Nancy Coté
- Institut Universitaire de Cardiologie et de Pneumologie de QuébecUniversité LavalQuébecCanada
| | - Paul Poirier
- Institut Universitaire de Cardiologie et de Pneumologie de QuébecUniversité LavalQuébecCanada
- Faculty of pharmacyUniversité LavalQuébecCanada
| | - Pierre Douville
- Centre Hospitalier Universitaire de QuébecUniversité LavalQuébecCanada
| | - Jonatan Blais
- Centre Hospitalier Universitaire de QuébecUniversité LavalQuébecCanada
| | - Philippe Desmeules
- Institut Universitaire de Cardiologie et de Pneumologie de QuébecUniversité LavalQuébecCanada
- Centre Hospitalier Universitaire de QuébecUniversité LavalQuébecCanada
| | - Dimitris Kalavrouziotis
- Institut Universitaire de Cardiologie et de Pneumologie de QuébecUniversité LavalQuébecCanada
| | - Siamak Mohammadi
- Institut Universitaire de Cardiologie et de Pneumologie de QuébecUniversité LavalQuébecCanada
| | - Pierre Voisine
- Institut Universitaire de Cardiologie et de Pneumologie de QuébecUniversité LavalQuébecCanada
- Division of Cardiac SurgeryUniversity of Ottawa Heart InstituteOttawaOntarioCanada
| | - Mathieu Bernier
- Institut Universitaire de Cardiologie et de Pneumologie de QuébecUniversité LavalQuébecCanada
| | - Philippe Pibarot
- Institut Universitaire de Cardiologie et de Pneumologie de QuébecUniversité LavalQuébecCanada
| | - Sébastien Thériault
- Institut Universitaire de Cardiologie et de Pneumologie de QuébecUniversité LavalQuébecCanada
| |
Collapse
|
2
|
Green AD, Lee GR. An appraisal of the practice of duplicate testing for the detection of irregular analytical errors. Clin Chem Lab Med 2024; 62:627-634. [PMID: 37942778 DOI: 10.1515/cclm-2022-0605] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2022] [Accepted: 10/17/2023] [Indexed: 11/10/2023]
Abstract
OBJECTIVES Our study aimed to determine the usefulness of duplicate testing in identifying irregular analytical errors and subsequent prevention of patient mismanagement. METHODS In our laboratory, all requests for Na+, Ca2+, alkaline phosphatase (ALP), and high-sensitivity cardiac-troponin-I (hs-cTnI) are run in duplicate. Data from four separate weeks for Na+ (n=21,649), Ca2+ (n=14,803) and ALP (n=19,698); and a full year for hs-cTnI (n=17,036) were gathered. For each test, pre-defined limits for differences between duplicates were used to identify erroneous results (Fliers). We further characterised a subset of such fliers as "critical errors", where duplicates fell on opposing sides of a reference/decision making threshold. The costs/benefits of running these tests in duplicate were then considered in light of increased number of tests analysed by this approach. RESULTS For Na+, 0.03 % of duplicates met our flier defining criteria, and 0.01 % of specimens were considered critical errors. For Ca2+ requests, 4.58 % of results met our flier defining criteria and 0.84 % were critical errors. For ALP, 0.22 % of results were fliers, and 0.01 % were critical errors. For hs-cTnI, 1.58 % of results were classified as fliers, whilst 0.14 % were classified as a critical error. Depending on the test in question, running all analyses in duplicate increased annual costs by as little as €1,100 (for sodium), and as much as €48,000 (for hs-cTnI). CONCLUSIONS Duplicate testing is effective at identifying and mitigating irregular laboratory errors, and is best suited for assays predisposed to such error, where costs are minimal, and clinical significance of an incorrect result can justify the practice.
Collapse
Affiliation(s)
- Alastair D Green
- Department of Clinical Biochemistry and Diagnostic Endocrinology, Mater Misericordiae University Hospital, Dublin, Ireland
| | - Graham R Lee
- Department of Clinical Biochemistry and Diagnostic Endocrinology, Mater Misericordiae University Hospital, Dublin, Ireland
| |
Collapse
|
3
|
Wauthier L, Cabo J, Eucher C, Rosseels C, Elsen M, Favresse J. Biotin interference in immunoassays: water under the bridge? Clin Chem Lab Med 2023; 61:e196-e199. [PMID: 37036736 DOI: 10.1515/cclm-2023-0242] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2023] [Accepted: 03/28/2023] [Indexed: 04/11/2023]
Affiliation(s)
- Loris Wauthier
- Department of Laboratory Medicine, Clinique St-Luc Bouge, Namur, Belgium
| | - Julien Cabo
- Department of Laboratory Medicine, Clinique St-Luc Bouge, Namur, Belgium
| | - Christine Eucher
- Department of Laboratory Medicine, Clinique St-Luc Bouge, Namur, Belgium
| | - Catherine Rosseels
- Department of Laboratory Medicine, Clinique St-Luc Bouge, Namur, Belgium
| | - Marc Elsen
- Department of Laboratory Medicine, Clinique St-Luc Bouge, Namur, Belgium
| | - Julien Favresse
- Department of Laboratory Medicine, Clinique St-Luc Bouge, Namur, Belgium
- Department of Pharmacy, Namur Research Institute for LIfes Sciences, University of Namur, Namur, Belgium
| |
Collapse
|
4
|
Bosi D, Canovi S, Pennacchioni A, Demola P, Corradini M, Guiducci V, Colla R, Navazio A. "Troponinosis", the Cardiologist's Curse-When Clinic-Laboratory Interaction Unveils the Mystery: A Case Report. J Cardiovasc Dev Dis 2023; 10:378. [PMID: 37754807 PMCID: PMC10531523 DOI: 10.3390/jcdd10090378] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2023] [Revised: 08/19/2023] [Accepted: 08/22/2023] [Indexed: 09/28/2023] Open
Abstract
Cardiac troponins are key diagnostic and prognostic biomarkers in acute myocardial infarction and, more generally, for the detection of myocardial injury. Since the introduction of the first immunochemistry methods, there has been a remarkable evolution in analytical performance, especially concerning a progressive improvement in sensitivity. However, the measurement of circulating troponins remains rarely susceptible to analytical interferences. We report a case of persistently elevated troponin I concentrations in a patient with known ischemic heart disease, which almost led to unnecessary diagnostic-therapeutic interventions. A prompt laboratory consultation by the cardiologist ultimately led to the identification of an analytical interference due to troponin macrocomplexes (macrotroponin) causing elevated troponin values in the absence of a clinical presentation compatible with myocardial damage.
Collapse
Affiliation(s)
- Davide Bosi
- Cardiology Unit, AUSL—IRCCS di Reggio Emilia, 42100 Reggio Emilia, Italy; (A.P.); (P.D.); (V.G.); (A.N.)
| | - Simone Canovi
- Clinical Laboratory Unit, AUSL—IRCCS di Reggio Emilia, 42100 Reggio Emilia, Italy; (S.C.); (M.C.); (R.C.)
| | - Andrea Pennacchioni
- Cardiology Unit, AUSL—IRCCS di Reggio Emilia, 42100 Reggio Emilia, Italy; (A.P.); (P.D.); (V.G.); (A.N.)
| | - Pierluigi Demola
- Cardiology Unit, AUSL—IRCCS di Reggio Emilia, 42100 Reggio Emilia, Italy; (A.P.); (P.D.); (V.G.); (A.N.)
| | - Mattia Corradini
- Clinical Laboratory Unit, AUSL—IRCCS di Reggio Emilia, 42100 Reggio Emilia, Italy; (S.C.); (M.C.); (R.C.)
| | - Vincenzo Guiducci
- Cardiology Unit, AUSL—IRCCS di Reggio Emilia, 42100 Reggio Emilia, Italy; (A.P.); (P.D.); (V.G.); (A.N.)
| | - Rossana Colla
- Clinical Laboratory Unit, AUSL—IRCCS di Reggio Emilia, 42100 Reggio Emilia, Italy; (S.C.); (M.C.); (R.C.)
| | - Alessandro Navazio
- Cardiology Unit, AUSL—IRCCS di Reggio Emilia, 42100 Reggio Emilia, Italy; (A.P.); (P.D.); (V.G.); (A.N.)
| |
Collapse
|
5
|
Hammarsten O, Warner JV, Lam L, Kavsak P, Lindahl B, Aakre KM, Collinson P, Jaffe AS, Saenger AK, Body R, Mills NL, Omland T, Ordonez-Llanos J, Apple FS. Antibody-mediated interferences affecting cardiac troponin assays: recommendations from the IFCC Committee on Clinical Applications of Cardiac Biomarkers. Clin Chem Lab Med 2023; 61:1411-1419. [PMID: 36952681 DOI: 10.1515/cclm-2023-0028] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2023] [Accepted: 01/12/2023] [Indexed: 03/25/2023]
Abstract
The International Federation of Clinical Chemistry Committee on Clinical Applications of Cardiac Biomarkers (IFCC C-CB) provides educational documents to facilitate the interpretation and use of cardiac biomarkers in clinical laboratories and practice. Our aim is to improve the understanding of certain key analytical and clinical aspects of cardiac biomarkers and how these may interplay. Measurements of cardiac troponin (cTn) have a prominent place in the clinical work-up of patients with suspected acute coronary syndrome. It is therefore important that clinical laboratories know how to recognize and assess analytical issues. Two emerging analytical issues resulting in falsely high cTn concentrations, often several fold higher than the upper reference limit (URL), are antibody-mediated assay interference due to long-lived cTn-antibody complexes, called macrotroponin, and crosslinking antibodies that are frequently referred to as heterophilic antibodies. We provide an overview of antibody-mediated cTn assay interference and provide recommendations on how to confirm the interference and interpret the results.
Collapse
Affiliation(s)
- Ola Hammarsten
- Department of Clinical Chemistry and Transfusion Medicine, University of Gothenburg, Gothenburg, Sweden
| | - Janet V Warner
- Faculty of Medicine, The University of Queensland, Saint Lucia, Australia
| | - Leo Lam
- Chemical Pathology, LabPlus, Auckland City Hospital, Auckland, New Zealand
- Biochemistry, Middlemore Hospital Laboratories, Auckland, New Zealand
| | - Peter Kavsak
- Department of Pathology and Molecular Medicine, McMaster University, Hamilton, ON, Canada
| | - Bertil Lindahl
- Department of Medical Sciences, Uppsala University and Uppsala Clinical Research Center, Uppsala University, Uppsala, Sweden
| | - Kristin M Aakre
- Department of Medical Biochemistry and Pharmacology and Department of Heart Disease, Haukeland University Hospital, Bergen, Norway
- Department of Clinical Science, University of Bergen, Bergen, Norway
| | - Paul Collinson
- Departments of Clinical Blood Sciences and Cardiology, St George's University Hospitals NHS Foundation Trust, London, UK
- St George's University of London, London, UK
| | - Allan S Jaffe
- Departments of Laboratory Medicine and Pathology and Cardiology, Mayo Clinic, Rochester, MN, USA
| | - Amy K Saenger
- Department of Laboratory Medicine and Pathology, Hennepin Healthcare/HCMC, Minneapolis, MN, USA
- Department of Laboratory Medicine and Pathology, University of Minnesota, Minneapolis, MN, USA
| | - Richard Body
- Emergency Department, Manchester University NHS Foundation Trust, Manchester Academic Health Science Centre, Manchester, UK
- Division of Cardiovascular Sciences, The University of Manchester, Manchester, UK
- Healthcare Sciences Department, Manchester Metropolitan University, Manchester, UK
| | - Nicholas L Mills
- BHF/University Centre for Cardiovascular Science and Usher Institute, University of Edinburgh, Edinburgh, UK
| | - Torbjørn Omland
- Department of Cardiology, Akershus University Hospital, Lørenskog, Norway
- Institute of Clinical Medicine, University of Oslo, Oslo, Norway
| | - Jordi Ordonez-Llanos
- Servicio de Bioquímica Clínica, Hospital de Sant Pau, Barcelona, Spain
- Foundation for the Biochemistry and Molecular Pathology, Barcelona, Spain
| | - Fred S Apple
- Department of Laboratory Medicine and Pathology, Hennepin Healthcare/HCMC, Minneapolis, MN, USA
- Department of Laboratory Medicine and Pathology, University of Minnesota, Minneapolis, MN, USA
| |
Collapse
|
6
|
Hammarsten O, Becker C, Engberg AE. Methods for analyzing positive cardiac troponin assay interference. Clin Biochem 2023; 116:24-30. [PMID: 36889375 DOI: 10.1016/j.clinbiochem.2023.03.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2022] [Revised: 02/28/2023] [Accepted: 03/03/2023] [Indexed: 03/08/2023]
Abstract
OBJECTIVES The cardiac damage biomarkers cardiac troponin T (cTnT) and troponin I (cTnI) are used to identify patients with myocardial infarction (MI). To make the correct clinical decisions it is important to identify false positive results due to troponin assay interference. Often interferences are caused by high-molecular weight immunocomplexes called macrotroponin that may result in false troponin elevations because of delayed troponin clearance, or heterophilic antibodies that crosslink troponin assay antibodies and generate troponin-independent signals. DESIGN & METHODS We describe and compare four methods for cTnI assay interference analysis using a protein G spin column method, gel filtration chromatography and two versions of a sucrose gradient ultracentrifugation for cTnI assay interference analysis on five patients with confirmed cTnI interference and one MI patient without cTnI interference from our troponin interference referral center. RESULTS The protein G spin column method had a high between run variability but was still able to identify all five patients with cTnI interference. The sucrose gradient ultracentrifugation methods and the gel filtration method had simlar performancec and correctly identified the immunocomplexes that caused the cTnI interference. CONCLUSIONS Our experience is that these methods are sufficient to safely confirm or exclude positive cTnI assay interference.
Collapse
Affiliation(s)
- Ola Hammarsten
- Department of Clinical Chemistry and Transfusion Medicine, Sahlgrenska Academy at University of Gothenburg, SE41345 Gothenburg, Sweden.
| | - Charlotte Becker
- Department of Clinical Chemistry and Pharmacology, Regional and University Laboratories, Region Skåne, Sweden
| | - Anna E Engberg
- Department of Clinical Chemistry and Pharmacology, Regional and University Laboratories, Region Skåne, Sweden
| |
Collapse
|
7
|
Deltombe M, Gruson D. High-sensitive cardiac troponin T: are turbulences coming? Clin Chem Lab Med 2023; 61:e11-e12. [PMID: 35998634 DOI: 10.1515/cclm-2022-0497] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2022] [Accepted: 08/15/2022] [Indexed: 12/15/2022]
Affiliation(s)
- Matthieu Deltombe
- Department of Clinical Biochemistry, Cliniques Universitaires St-Luc and Université Catholique de Louvain, Brussels, Belgium
| | - Damien Gruson
- Department of Clinical Biochemistry, Cliniques Universitaires St-Luc and Université Catholique de Louvain, Brussels, Belgium
| |
Collapse
|
8
|
Tian T, Zhang J, Xiong L, Yu H, Deng K, Liao X, Zhang F, Huang P, Zhang J, Chen Y. Evaluating Subtle Pathological Changes in Early Myocardial Ischemia Using Spectral Histopathology. Anal Chem 2022; 94:17112-17120. [PMID: 36442494 DOI: 10.1021/acs.analchem.2c03368] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Early myocardial ischemia (EMI) is morphologically challenging, and the results from conventional histological staining may be subjective, imprecise, or even silent. The size of myocardial necrosis determines the acute and long-term mortality of EMI. The precise diagnosis of myocardial ischemia is critical for both clinical management and forensic investigation. Fourier transform infrared (FTIR) spectroscopic imaging is a highly sensitive tool for detecting protein conformations and imaging protein profiles. The aim of this study was to evaluate the application of FTIR imaging with multivariate analysis to detect biochemical changes in the protein conformation in the early phase of myocardial ischemia and to visually classify different disease states. The spectra and curve fitting results revealed that the total protein content decreased significantly in the EMI group and that the α-helix content of the secondary protein structure continuously decreased as ischemia progressed, while the β-sheet content increased. Differences in the control and EMI groups and perfused and ischemic myocardium were confirmed using principal component analysis and partial least squares discriminant analysis. Next, two support vector machine classifiers were effectively created. The accuracy, recall, and precision were 99.98, 99.96, and 100.00%, respectively, to differentiate the EMI group from the control group and 99.25, 98.95, and 99.54%, respectively, to differentiate perfused and ischemic myocardium. Ultimately, high EMI diagnostic accuracy was achieved with 100.00% recall and 100.00% precision, and ischemic myocardium diagnostic accuracy was achieved with 99.30% recall and 99.53% precision for the test set. This pilot study demonstrated that FTIR imaging is a powerful automated quantitative analysis tool to detect EMI without morphological changes and will improve diagnostic accuracy and patient prognosis.
Collapse
Affiliation(s)
- Tian Tian
- Department of Forensic Pathology, West China School of Basic Medical Sciences & Forensic Medicine, Sichuan University, Chengdu, Sichuan 610041, P. R. China.,Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Ministry of Justice, P. R. China, Shanghai 200063, China
| | - Jianhua Zhang
- Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Ministry of Justice, P. R. China, Shanghai 200063, China
| | - Ling Xiong
- Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Ministry of Justice, P. R. China, Shanghai 200063, China.,Department of Forensic Medicine, Guizhou Medical University, Guiyang, Guizhou 550004, P. R. China
| | - Haixing Yu
- Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Ministry of Justice, P. R. China, Shanghai 200063, China.,College of Medicine & Forensics, Xi'an Jiaotong University Health Science Center, Xi'an, Shaanxi 710061, P. R. China
| | - Kaifei Deng
- Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Ministry of Justice, P. R. China, Shanghai 200063, China
| | - Xinbiao Liao
- Key Laboratory of Forensic Pathology, Ministry of Public Security, P. R. China, Guangzhou 510050, Guangdong, China
| | - Fu Zhang
- Key Laboratory of Forensic Pathology, Ministry of Public Security, P. R. China, Guangzhou 510050, Guangdong, China
| | - Ping Huang
- Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Ministry of Justice, P. R. China, Shanghai 200063, China
| | - Ji Zhang
- Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Ministry of Justice, P. R. China, Shanghai 200063, China
| | - Yijiu Chen
- Department of Forensic Pathology, West China School of Basic Medical Sciences & Forensic Medicine, Sichuan University, Chengdu, Sichuan 610041, P. R. China.,Shanghai Key Laboratory of Forensic Medicine, Shanghai Forensic Service Platform, Academy of Forensic Science, Ministry of Justice, P. R. China, Shanghai 200063, China
| |
Collapse
|
9
|
Collinson P. Macrotroponin-Analytical Anomaly or Clinical Confounder. Clin Chem 2022; 68:1229-1231. [PMID: 35929570 DOI: 10.1093/clinchem/hvac129] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2022] [Accepted: 07/11/2022] [Indexed: 11/13/2022]
Affiliation(s)
- Paul Collinson
- Departments of Clinical Blood Sciences and Cardiology, St George's University Hospitals NHS Foundation Trust and St George's University of London, Cranmer Terrace, London, UK
| |
Collapse
|
10
|
Favresse J, Schiettecatte J, Wolff F, Cotton F, Elsen M, Eucher C, Rosseels C, Anckaert E. Two-site evaluation of the Roche Elecsys Vitamin D total III assay. Clin Chem Lab Med 2022; 60:1598-1606. [DOI: 10.1515/cclm-2022-0177] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2022] [Accepted: 07/03/2022] [Indexed: 11/15/2022]
Abstract
Abstract
Objectives
The high request for vitamin D testing in the last decades has led manufacturers to develop assays on automated immunoassay platforms. The objective of this study was to evaluate the performance of the new Elecsys Vitamin D total III assay for the measurement of total 25(OH)D.
Methods
A total of 844 serum samples collected in two clinical laboratories were used to evaluate the new Roche Elecsys Vitamin D total III assay. Comparisons with Roche Elecsys Vitamin D total II and liquid chromatography tandem mass spectrometry (LC-MS/MS) were carried out. Additionally, assay imprecision, linearity, matrix effects, biotin interference, cross-reactivity with 24,25(OH)2D3 and 3-epi-25(OH)D3, and outlier rate were evaluated for the Elecsys Vitamin D total III assay.
Results
Only the comparison between LC-MS/MS and Roche Elecsys Vitamin D total III achieved the optimal specification for bias (i.e., <3.4%). Imprecision, linearity and matrix effects showed acceptable results. The biotin interference threshold was increased up to 1,200 ng/mL and the outlier rate was low (0.26%). The cross-reactivity with 24,25(OH)2D3 and 3-epi-25(OH)D3 was weak or modest in available patient samples. However, using SRM972a with a high level of 3-epi-25(OH)D3 (enriched) revealed an important cross-reactivity with both Roche Elecsys Vitamin D total II and III assays (+74.7% and +73.7%).
Conclusions
In conclusion, the Roche Elecsys Vitamin D total III assay presents several advantages compared to the previous assay generation: higher biotin interference threshold, broader measuring range, and better comparability with LC-MS/MS. However, the cross-reactivity toward 3-epi-25(OH)D3 is still problematic in high titer samples.
Collapse
Affiliation(s)
- Julien Favresse
- Department of Laboratory Medicine , Clinique St-Luc Bouge , Namur , Belgium
- Department of Pharmacy , Namur Research Institute for Life Sciences, University of Namur , Namur , Belgium
| | - Johan Schiettecatte
- Department of Clinical Chemistry and Radioimmunology , Vrije Universiteit Brussel, Universitair Ziekenhuis Brussel (UZ Brussel) , Brussels , Belgium
| | - Fleur Wolff
- Department of Clinical Chemistry , LHUB-ULB, Université Libre de Bruxelles , Brussels , Belgium
| | - Frederic Cotton
- Department of Clinical Chemistry , LHUB-ULB, Université Libre de Bruxelles , Brussels , Belgium
| | - Marc Elsen
- Department of Laboratory Medicine , Clinique St-Luc Bouge , Namur , Belgium
| | - Christine Eucher
- Department of Laboratory Medicine , Clinique St-Luc Bouge , Namur , Belgium
| | - Catherine Rosseels
- Department of Laboratory Medicine , Clinique St-Luc Bouge , Namur , Belgium
| | - Ellen Anckaert
- Department of Clinical Chemistry and Radioimmunology , Vrije Universiteit Brussel, Universitair Ziekenhuis Brussel (UZ Brussel) , Brussels , Belgium
| |
Collapse
|
11
|
Crea F. Antiplatelet treatment of acute coronary syndromes: novel clinical and translational perspectives. Eur Heart J 2022; 43:2253-2256. [PMID: 35724980 DOI: 10.1093/eurheartj/ehac311] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Affiliation(s)
- Filippo Crea
- Department of Cardiovascular Medicine, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy.,Department of Cardiovascular and Pulmonary Sciences, Catholic University of the Sacred Heart, Rome, Italy
| |
Collapse
|
12
|
Wauthier L, Plebani M, Favresse J. Interferences in immunoassays: review and practical algorithm. Clin Chem Lab Med 2022; 60:808-820. [PMID: 35304841 DOI: 10.1515/cclm-2021-1288] [Citation(s) in RCA: 36] [Impact Index Per Article: 18.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2021] [Accepted: 03/01/2022] [Indexed: 12/14/2022]
Abstract
Immunoassays are currently the methods of choice for the measurement of a large panel of complex and heterogenous molecules owing to full automation, short turnaround time, high specificity and sensitivity. Despite remarkable performances, immunoassays are prone to several types of interferences that may lead to harmful consequences for the patient (e.g., prescription of an inadequate treatment, delayed diagnosis, unnecessary invasive investigations). A systematic search is only performed for some interferences because of its impracticality in clinical laboratories as it would notably impact budget, turnaround time, and human resources. Therefore, a case-by-case approach is generally preferred when facing an aberrant result. Hereby, we review the current knowledge on immunoassay interferences and present an algorithm for interference workup in clinical laboratories, from suspecting their presence to using the appropriate tests to identify them. We propose an approach to rationalize the attitude of laboratory specialists when faced with a potential interference and emphasize the importance of their collaboration with clinicians and manufacturers to ensure future improvements.
Collapse
Affiliation(s)
- Loris Wauthier
- Department of Laboratory Medicine, Clinique St-Luc Bouge, Namur, Belgium
| | - Mario Plebani
- Department of Laboratory Medicine, University-Hospital of Padova, Padova, Italy
| | - Julien Favresse
- Department of Laboratory Medicine, Clinique St-Luc Bouge, Namur, Belgium
- Department of Pharmacy, Namur Research Institute for LIfes Sciences, University of Namur, Namur, Belgium
| |
Collapse
|