1
|
Mills MT, Calvert P, Gupta D. Radiofrequency catheter ablation of cardiac arrhythmias: Don't get burned. HeartRhythm Case Rep 2024; 10:248-249. [PMID: 38766621 PMCID: PMC11096421 DOI: 10.1016/j.hrcr.2024.01.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/22/2024] Open
Affiliation(s)
- Mark T. Mills
- Liverpool Centre for Cardiovascular Science at University of Liverpool, Liverpool John Moores University and Liverpool Heart & Chest Hospital, Liverpool, United Kingdom
- Department of Cardiology, Liverpool Heart & Chest Hospital NHS Foundation Trust, Liverpool, United Kingdom
| | - Peter Calvert
- Liverpool Centre for Cardiovascular Science at University of Liverpool, Liverpool John Moores University and Liverpool Heart & Chest Hospital, Liverpool, United Kingdom
- Department of Cardiology, Liverpool Heart & Chest Hospital NHS Foundation Trust, Liverpool, United Kingdom
| | - Dhiraj Gupta
- Liverpool Centre for Cardiovascular Science at University of Liverpool, Liverpool John Moores University and Liverpool Heart & Chest Hospital, Liverpool, United Kingdom
- Department of Cardiology, Liverpool Heart & Chest Hospital NHS Foundation Trust, Liverpool, United Kingdom
| |
Collapse
|
2
|
Zeng L, Chen S, Zeng R, Hu H, Yang Q, Cui K, Chen Q, Fu H, Pu X. CLOSE protocol versus lower ablation index value for paroxysmal atrial fibrillation: A randomized noninferior clinical trial. J Cardiovasc Electrophysiol 2024; 35:469-477. [PMID: 38282257 DOI: 10.1111/jce.16194] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/12/2023] [Revised: 01/02/2024] [Accepted: 01/14/2024] [Indexed: 01/30/2024]
Abstract
INTRODUCTION The optimized ablation index (AI) value for catheter ablation of atrial fibrillation (AF) remains to be defined. We aimed to compare the efficacy and safety of CLOSE protocol and lower AI protocol in paroxysmal AF. METHODS AND RESULTS Patients with symptomatic, drug-resistant paroxysmal AF for first ablation were prospectively enrolled from September 2020 to January 2022. The patients were randomly divided into CLOSE group (AI ≥ 550 for anterior/roof segments and ≥400 for posterior/inferior segments) and lower AI group (AI ≥ 450 for anterior/roof segments and ≥350 for posterior/inferior segments). First-pass isolation, acute pulmonary vein (PV) reconnections, 1-year arrhythmia recurrence, and major complications were assessed. Of the 270 enrolled patients, 238 completed 1-year follow-up (118 in CLOSE group and 120 in lower AI group). First-pass isolation in left PVs was higher in CLOSE group (71.2% vs. 53.3%, p = .005). Acute PV reconnections were comparable between groups (9.3% vs. 14.2%, p = .246). At 1 year, 86.4% in CLOSE group versus 81.7% in lower AI group were free from atrial arrhythmia (log rank p = .334). The proportion difference was -4.8% (95% CI: -14.1% to 4.6%), and p = .475 for noninferiority. Stroke occurred in four patients of lower AI group, and no cardiac tamponade, atrioesophageal fistula, major bleeding or death occurred post procedure. CONCLUSION For patients with paroxysmal AF and treated by AI-guided PV ablation, lower AI is not noninferior to CLOSE protocol.
Collapse
Affiliation(s)
- Lijun Zeng
- Laboratory of Heart Valve Disease, West China Hospital, Sichuan University, Chengdu, China
| | - Shi Chen
- Department of Cardiology, West China Hospital, Sichuan University, Chengdu, China
| | - Rui Zeng
- Department of Cardiology, West China Hospital, Sichuan University, Chengdu, China
| | - Hongde Hu
- Department of Cardiology, West China Hospital, Sichuan University, Chengdu, China
| | - Qing Yang
- Department of Cardiology, West China Hospital, Sichuan University, Chengdu, China
| | - Kaijun Cui
- Department of Cardiology, West China Hospital, Sichuan University, Chengdu, China
| | - Qingyong Chen
- Department of Cardiology, West China Hospital, Sichuan University, Chengdu, China
| | - Hua Fu
- Department of Cardiology, West China Hospital, Sichuan University, Chengdu, China
| | - Xiaobo Pu
- Department of Cardiology, West China Hospital, Sichuan University, Chengdu, China
| |
Collapse
|
3
|
Junarta J, Rodriguez S, Ullah W, Siddiqui MU, Riley JM, Patel A, O'Neill P, Dikdan SJ, Fradin JJ, Rosen JL, Frisch DR. Comparison of very high-power short-duration, high-power short-duration, and low-power long-duration radiofrequency ablation for atrial fibrillation: A systematic review and network meta-analysis. Pacing Clin Electrophysiol 2023; 46:1609-1634. [PMID: 37971718 DOI: 10.1111/pace.14879] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/07/2023] [Accepted: 11/05/2023] [Indexed: 11/19/2023]
Abstract
BACKGROUND The optimal power and duration settings for radiofrequency (RF) atrial fibrillation (AF) ablation to improve efficacy and safety is unclear. We compared low-power long-duration (LPLD), high-power short-duration (HPSD), and very HPSD (vHPSD) RF settings for AF ablation. METHODS This network meta-analysis (NMA) was structured according to the Preferred Reporting Items for Systematic Review and Meta-Analyses guidelines. Medline, Scopus and Cochrane Central Register of Controlled Trials were systematically searched to identify relevant studies. Observational and randomized studies were included. Eligible studies compared outcomes in AF patients who underwent first-time RF ablation with the following settings: vHPSD (70-90 W, 3-10 s), HPSD (45-60 W, 5-10 s), or LPLD (20-40 W, 20-60 s). RESULTS Thirty-six studies comprising 10,375 patients were included (33% female). Frequentist NMA showed LPLD tended toward a lower odds of freedom from arrhythmia (FFA) versus HPSD (OR 0.93, 95% CI 0.86-1.00). There was no difference in FFA between vHPSD versus HPSD. Splitwise interval estimates showed a lower odds of FFA in LPLD versus vHPSD on direct (OR 0.78, 95% CI 0.65-0.93) and network estimates (OR 0.85, 95% CI 0.73-0.98). Frequentist NMA showed less total procedural (TP) time with HPSD versus LPLD (generic variance 1.06, 95% CI 0.83 to 1.29) and no difference between HPSD versus vHPSD. CONCLUSION This NMA shows improved procedural times in HPSD and vHPSD versus LPLD. Although HPSD tended toward improved odds of FFA compared to LPLD, the overall result was not statistically significant. The odds of FFA in LPLD was lower versus vHPSD on direct and network estimates on splitwise interval analysis. Large prospective head-to-head randomized trials are needed to validate HPSD and vHPSD settings.
Collapse
Affiliation(s)
- Joey Junarta
- Department of Medicine, Thomas Jefferson University Hospital, Philadelphia, USA
| | - Sebastian Rodriguez
- Jefferson Heart Institute, Thomas Jefferson University Hospital, Philadelphia, USA
| | - Waqas Ullah
- Jefferson Heart Institute, Thomas Jefferson University Hospital, Philadelphia, USA
| | - Muhammad U Siddiqui
- Jefferson Heart Institute, Thomas Jefferson University Hospital, Philadelphia, USA
| | - Joshua M Riley
- Department of Medicine, Thomas Jefferson University Hospital, Philadelphia, USA
| | - Anjani Patel
- Department of Medicine, Thomas Jefferson University Hospital, Philadelphia, USA
| | - Parker O'Neill
- Department of Medicine, Thomas Jefferson University Hospital, Philadelphia, USA
| | - Sean J Dikdan
- Jefferson Heart Institute, Thomas Jefferson University Hospital, Philadelphia, USA
| | - James J Fradin
- Sidney Kimmel Medical College, Thomas Jefferson University, Philadelphia, USA
| | - Jake L Rosen
- Sidney Kimmel Medical College, Thomas Jefferson University, Philadelphia, USA
| | - Daniel R Frisch
- Jefferson Heart Institute, Thomas Jefferson University Hospital, Philadelphia, USA
| |
Collapse
|
4
|
Waranugraha Y, Tsai CT, Lin LY. Index-Guided High-Power Radiofrequency Catheter Ablation for Atrial Fibrillation: A Systematic Review and Meta-Analysis Study. Curr Cardiol Rep 2023; 25:1397-1414. [PMID: 37874469 DOI: 10.1007/s11886-023-01968-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 09/11/2023] [Indexed: 10/25/2023]
Abstract
PURPOSE OF REVIEW Studies have suggested the superiority of high-power compared to standard-power radiofrequency ablation ablation (RFCA). This study aimed to assess the efficacy and safety of high-power compared to standard-power RFCA guided by ablation index (AI) or lesion index (LSI). RECENT FINDINGS A systematic review and meta-analysis study comparing IGHP and IGLP approaches for AF ablation was conducted. The relevant published studies comparing IGHP and IGSP methods for RFCA in AF patients until October 2022 were collected from Cochrane, ProQuest, PubMed, and ScienceDirect. A total of 2579 AF patients from 11 studies were included, 1682 received IGHP RFCA, and 897 received IGSP RFCA. To achieve successful pulmonary vein isolation (PVI), the IGHP RFCA group had a significantly shorter procedure time than the IGHP RFCA group (mean difference (MD) -19.91 min; 95% CI -25.23 to -14.59 min; p < 0.01), radiofrequency (RF) application time (MD -10.92 min; 95% CI -14.70 to -7.13 min; p < 0.01), and fewer number of lesions (MD -10.90; 95% CI -18.77 to -3.02; p < 0.01) than the IGSP RFCA. First-pass PVI was significantly greater in the IGHP RFCA group than in the IGSP RFCA group (risk ratio (RR) 1.17; 95% CI 1.07 to 1.28; p < 0.01). The IGHP RFCA is an effective and efficient strategy for AF ablation. The superiority of IGHP RFCA includes the shorter procedure time, shorter RF application time, fewer number of lesions for complete PVI, and more excellent first-pass PVI.
Collapse
Affiliation(s)
- Yoga Waranugraha
- Department of Cardiology and Vascular Medicine, Faculty of Medicine Universitas Brawijaya, Universitas Brawijaya Hospital, Malang, Indonesia
| | - Chia-Ti Tsai
- Division of Cardiology, Department of Internal Medicine, National Taiwan University Hospital, National Taiwan University College of Medicine, Taipei, Taiwan
| | - Lian-Yu Lin
- Division of Cardiology, Department of Internal Medicine, National Taiwan University Hospital, National Taiwan University College of Medicine, Taipei, Taiwan.
| |
Collapse
|
5
|
Boersma L, Andrade JG, Betts T, Duytschaever M, Pürerfellner H, Santoro F, Tzeis S, Verma A. Progress in atrial fibrillation ablation during 25 years of Europace journal. Europace 2023; 25:euad244. [PMID: 37622592 PMCID: PMC10451004 DOI: 10.1093/europace/euad244] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2023] [Accepted: 08/08/2023] [Indexed: 08/26/2023] Open
Abstract
The first edition of Europace journal in 1999 came right around the time of the landmark publication of the electrophysiologists from Bordeaux, establishing how elimination of ectopic activity from the pulmonary veins (PVs) resulted in a marked reduction of atrial fibrillation (AF). The past 25 years have seen an incredible surge in scientific interest to develop new catheters and energy sources to optimize durability and safety of ablation, as well as study the mechanisms for AF and devise ablation strategies. While ablation in the beginning was performed with classic 4 mm tip catheters that emitted radiofrequency (RF) energy to create tissue lesions, this evolved to using irrigation and contact force (CF) measurement while increasing power. Also, so-called single-shot devices were developed with balloons and arrays to create larger contiguous lesions, and energy sources changed from RF current to cryogenic ablation and more recently pulsed field ablation with electrical current. Although PV ablation has remained the basis for every AF ablation, it was soon recognized that this was not enough to cure all patients, especially those with non-paroxysmal AF. Standardized approaches for additional ablation targets have been used but have not been satisfactory in all patients so far. This led to highly technical mapping systems that are meant to unravel the drivers for the maintenance of AF. In the following sections, the development of energies, strategies, and tools is described with a focus on the contribution of Europace to publish the outcomes of studies that were done during the past 25 years.
Collapse
Affiliation(s)
- Lucas Boersma
- Cardiology Department, St. Antonius Hospital Nieuwegein/Amsterdam University Medical Center, PO 2500, 3430 EM Nieuwegein, The Netherlands
| | - Jason G Andrade
- Department of Medicine, University of British Columbia, Vancouver, Canada
- Cardiology Department, Center for Cardiovascular Innovation, Vancouver, Canada
- Montreal Heart Institute, Department of Medicine, Université de Montréal, Montreal, Canada
| | - Tim Betts
- Department of Cardiology, Oxford University, Oxford, UK
| | | | | | - Francesco Santoro
- Department of Medical and Surgery Sciences, University of Foggia, Foggia, Italy
| | - Stylianos Tzeis
- Cardiology Department, Mitera Hospital, Hygeia Group, Athens, Greece
| | - Atul Verma
- Cardiology Department, McGill University Health Center, Montreal, Quebec, Canada
| |
Collapse
|
6
|
Sousa PA, Barra S, Saleiro C, Khoueiry Z, Adão L, Primo J, Lagrange P, Lebreiro A, Fonseca P, Pereira M, Puga L, Oliveiros B, Elvas L, Gonçalves L. Ostial vs. wide area circumferential ablation guided by the Ablation Index in paroxysmal atrial fibrillation. Europace 2023; 25:euad160. [PMID: 37345859 PMCID: PMC10286571 DOI: 10.1093/europace/euad160] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2023] [Accepted: 05/23/2023] [Indexed: 06/23/2023] Open
Abstract
AIMS Pulmonary vein isolation (PVI) guided by the Ablation Index (AI) has shown high acute and mid-term efficacy in the treatment of paroxysmal atrial fibrillation (AF). Previous data before the AI-era had suggested that wide-area circumferential ablation (WACA) was preferable to ostial ablation. However, with the use of AI, we hypothesize that ostial circumferential ablation is non-inferior to WACA and can improve outcomes in paroxysmal AF. METHODS AND RESULTS Prospective, multicentre, non-randomized, non-inferiority study of consecutive patients were referred for paroxysmal AF ablation from January 2020 to September 2021. All procedures were performed using the AI software, and patients were separated into two different groups: WACA vs. ostial circumferential ablation. Acute reconnection, procedural data, and 1-year arrhythmia recurrence were assessed. During the enrolment period, 162 patients (64% males, mean age of 60 ± 11 years) fulfilled the study inclusion criteria-81 patients [304 pulmonary vein (PV)] in the WACA group and 81 patients (301 PV) in the ostial group. Acute PV reconnection was identified in 7.9% [95% confidence interval (CI), 4.9-11.1%] of PVs in the WACA group compared with 3.3% (95% CI, 1.8-6.1%) of PVs in the ostial group [P < 0.001 for non-inferiority; adjusted odds ratio 0.51 (95% CI, 0.23-0.83), P = 0.05]. Patients in the WACA group had longer ablation (35 vs. 29 min, P = 0.001) and procedure (121 vs. 102 min, P < 0.001) times. No significant difference in arrhythmia recurrence was seen at 1-year of follow-up [11.1% in WACA vs. 9.9% in ostial, hazard ratio 1.13 (95% CI, 0.44-1.94), P = 0.80 for superiority]. CONCLUSION In paroxysmal AF patients treated with tailored AI-guided PVI, ostial circumferential ablation is not inferior to WACA with regard to acute PV reconnection, while allowing quicker procedures with less ablation time.
Collapse
Affiliation(s)
- Pedro A Sousa
- Pacing and Electrophysiology Unit, Department of Cardiology, Coimbra’s Hospital and University Center, Morada: Praceta Prof Mota Pinto, Coimbra 3000-075, Portugal
| | - Sérgio Barra
- Department of Cardiology, Hospital da Luz Arrábida, V. N. Gaia, Portugal
| | - Carolina Saleiro
- Pacing and Electrophysiology Unit, Department of Cardiology, Coimbra’s Hospital and University Center, Morada: Praceta Prof Mota Pinto, Coimbra 3000-075, Portugal
| | - Ziad Khoueiry
- Department of Cardiology, Clinique Saint Pierre, Perpignan, France
| | - Luís Adão
- Department of Cardiology, University Hospital Center of São João, Porto, Portugal
| | - João Primo
- Department of Cardiology, Vila Nova de Gaia and Espinho Hospital Center, V. N. Gaia, Portugal
| | | | - Ana Lebreiro
- Department of Cardiology, University Hospital Center of São João, Porto, Portugal
| | - Paulo Fonseca
- Department of Cardiology, Vila Nova de Gaia and Espinho Hospital Center, V. N. Gaia, Portugal
| | | | - Luís Puga
- Pacing and Electrophysiology Unit, Department of Cardiology, Coimbra’s Hospital and University Center, Morada: Praceta Prof Mota Pinto, Coimbra 3000-075, Portugal
| | | | - Luís Elvas
- Pacing and Electrophysiology Unit, Department of Cardiology, Coimbra’s Hospital and University Center, Morada: Praceta Prof Mota Pinto, Coimbra 3000-075, Portugal
| | - Lino Gonçalves
- Pacing and Electrophysiology Unit, Department of Cardiology, Coimbra’s Hospital and University Center, Morada: Praceta Prof Mota Pinto, Coimbra 3000-075, Portugal
- ICBR, Faculty of Medicine, University of Coimbra, Coimbra, Portugal
| |
Collapse
|
7
|
Chu G, Calvert P, Sidhu B, Mavilakandy A, Kotb A, Tovmassian L, Kozhuharov N, Biermé C, Denham N, Pius C, O'Brien J, Ding WY, Luther V, Snowdon RL, Ng GA, Gupta D. Patient experience of very high power short duration radiofrequency ablation for atrial fibrillation under mild conscious sedation. J Interv Card Electrophysiol 2023; 66:445-453. [PMID: 35997848 PMCID: PMC9396586 DOI: 10.1007/s10840-022-01351-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/15/2022] [Accepted: 08/15/2022] [Indexed: 11/29/2022]
Abstract
BACKGROUND Very high power short duration (vHPSD) radiofrequency ablation (RFA) may reduce ablation times and improve patient tolerability, permitting pulmonary vein isolation (PVI) under mild conscious sedation (mCS) and promoting same day discharge (SDD). METHODS First, a retrospective feasibility study was performed at 2 tertiary cardiac centres in the UK. Consecutive cases of first-time PVI using vHPSD ablation with 90 W lesions for up to 4 s were compared against cases performed using standard RF (sRF) and cryoballoon (Cryo) therapy. Subsequently, a prospective study of patients who had vHPSD or Cryo exclusively under mCS was undertaken. Questionnaires based on Likert and visual analogue scales (VAS) were used to measure anxiety, discomfort and pain. RESULTS In total, 182 patients (59 vHPSD, 62 sRF and 61 Cryo) were included in the retrospective study, with 53 (90%) of vHPSD cases successfully performed under mCS. PVI ablation time in the vHPSD group (5.8 ± 1.7 min) was shorter than for sRF (16.5 ± 6.3 min, p < 0.001) and Cryo (17.5 ± 5.9 min, p < 0.001). Fifty-one vHPSD and 52 Cryo patients were included in the prospective study. PVI ablation time in the vHPSD group was shorter than for the Cryo group (6.4 ± 2.9 min vs 17.9 ± 5.7 min, p < 0.001), but overall procedure duration was longer (121 ± 39 min vs 95 ± 20 min, p < 0.001). There were no differences in the patient experience of anxiety, discomfort or pain. SDD rates were the same in both groups (61% vs 67%, p = 0.49). CONCLUSIONS vHPSD RFA for PVI can be performed under mCS to achieve SDD rates comparable to cryoablation, without compromising patient experience.
Collapse
Affiliation(s)
- Gavin Chu
- Lancashire Cardiac Centre, Blackpool, UK
- Department of Cardiovascular Sciences, NIHR Leicester Biomedical Research Centre, University of Leicester, Leicester, UK
| | - Peter Calvert
- Liverpool Heart and Chest Hospital NHS Foundation Trust, Thomas Drive, Liverpool, L14 3PE, UK
| | - Bharat Sidhu
- Department of Cardiovascular Sciences, NIHR Leicester Biomedical Research Centre, University of Leicester, Leicester, UK
| | - Akash Mavilakandy
- Department of Cardiovascular Sciences, NIHR Leicester Biomedical Research Centre, University of Leicester, Leicester, UK
| | - Ahmed Kotb
- Department of Cardiovascular Sciences, NIHR Leicester Biomedical Research Centre, University of Leicester, Leicester, UK
| | - Lilith Tovmassian
- Liverpool Heart and Chest Hospital NHS Foundation Trust, Thomas Drive, Liverpool, L14 3PE, UK
| | - Nikola Kozhuharov
- Liverpool Heart and Chest Hospital NHS Foundation Trust, Thomas Drive, Liverpool, L14 3PE, UK
- Department of Cardiology and Cardiovascular Research Institute Basel (CRIB), University Hospital Basel, University of Basel, Basel, Switzerland
| | - Cédric Biermé
- Liverpool Heart and Chest Hospital NHS Foundation Trust, Thomas Drive, Liverpool, L14 3PE, UK
| | - Nathan Denham
- Liverpool Heart and Chest Hospital NHS Foundation Trust, Thomas Drive, Liverpool, L14 3PE, UK
| | - Charlene Pius
- Liverpool Heart and Chest Hospital NHS Foundation Trust, Thomas Drive, Liverpool, L14 3PE, UK
| | - Jim O'Brien
- Liverpool Heart and Chest Hospital NHS Foundation Trust, Thomas Drive, Liverpool, L14 3PE, UK
| | - Wern Yew Ding
- Liverpool Heart and Chest Hospital NHS Foundation Trust, Thomas Drive, Liverpool, L14 3PE, UK
| | - Vishal Luther
- Liverpool Heart and Chest Hospital NHS Foundation Trust, Thomas Drive, Liverpool, L14 3PE, UK
| | - Richard L Snowdon
- Liverpool Heart and Chest Hospital NHS Foundation Trust, Thomas Drive, Liverpool, L14 3PE, UK
| | - G André Ng
- Department of Cardiovascular Sciences, NIHR Leicester Biomedical Research Centre, University of Leicester, Leicester, UK
- Glenfield Hospital, Leicester, UK
| | - Dhiraj Gupta
- Liverpool Heart and Chest Hospital NHS Foundation Trust, Thomas Drive, Liverpool, L14 3PE, UK.
| |
Collapse
|
8
|
Cai C, Wang J, Niu HX, Chu JM, Hua W, Zhang S, Yao Y. Clinical outcome of lesion size index-guided high-power radiofrequency catheter ablation for pulmonary vein isolation in patients with atrial fibrillation: 2-year follow-up. J Cardiovasc Electrophysiol 2023; 34:546-555. [PMID: 36640429 DOI: 10.1111/jce.15809] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/31/2022] [Revised: 12/03/2022] [Accepted: 01/04/2023] [Indexed: 01/16/2023]
Abstract
INTRODUCTION The long-term efficacy of high-power (50 W) ablation guided by lesion size index (LSI-guided HP) for pulmonary vein isolation (PVI) in patients with atrial fibrillation (AF) remains undetermined. Our study sought to assess the clinical efficacy of LSI-guided HP ablation for PVI in patients with AF and explore the potential predictors associated with clinical outcomes. METHODS We consecutively included 186 patients with AF who underwent LSI-guided HP (50 W) ablation at Fuwai Hospital from June 2019 to October 2021. The target LSI values of 4.5-5.5 and 4.0-4.5 at the anterior and posterior walls, respectively, were used in our study. The baseline clinical characteristics, procedural and ablation data, and clinical outcomes were evaluated. The independent potential predictors associated with AF recurrence were further evaluated. RESULTS The incidence rate of first-pass PVI was 83.9% (156/186). A total of 11 883 lesions were analyzed, and compared with posterior walls of pulmonary veins, anterior walls had significantly lower mean contact force (8.2 ± 3.0 vs. 8.3 ± 2.3 g, p = .015), longer mean radiofrequency duration (16.9 ± 7.2 vs. 12.9 ± 4.5 s, p < .001) and higher mean LSI (4.8 ± 0.2 vs. 4.4 ± 0.2, p < .001). The overall incidence of periprocedural complications was 3.7%, and steam pops without pericardial effusion occurred in three patients (1.6%). During a mean follow-up of 24.0 ± 8.4 months, the overall AF recurrence-free survival was 87.1% after a single procedure. Patients with paroxysmal AF had a higher incidence of freedom from AF recurrence than those with persistent AF (91.2% vs. 80.8%, log-rank p = .034). Higher LSI (HR 0.50, p < .001) and paroxysmal AF (HR 0.39, p = .029) were significantly associated with decreased AF recurrence. By receiver operating characteristic analysis, the LSI of 4.7 and 4.3 for the anterior and posterior walls of the PVs had the highest predictive value for AF recurrence, respectively. CONCLUSION LSI-guided HP (50 W) ablation for PVI was an efficient and safe strategy and led to favorable single-procedure 2-year AF recurrence-free survival in patients with AF. Higher LSI and paroxysmal AF were independent predictors of decreased 2-year AF recurrence. The LSI of 4.7 for the anterior wall and 4.3 for the posterior wall of the PVs were the best cutoff values for predicting AF recurrence after LSI-guided HP ablation.
Collapse
Affiliation(s)
- Chi Cai
- Cardiac Arrhythmia Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Jing Wang
- Cardiac Arrhythmia Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Hong-Xia Niu
- Cardiac Arrhythmia Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Jian-Min Chu
- Cardiac Arrhythmia Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Wei Hua
- Cardiac Arrhythmia Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Shu Zhang
- Cardiac Arrhythmia Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Yan Yao
- Cardiac Arrhythmia Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| |
Collapse
|
9
|
Jin S, Lin W, Fang X, Liao H, Zhan X, Fu L, Jiang J, Ye X, Liu H, Chen Y, Pu S, Wu S, Deng H, Xue Y. High-Power, Short-Duration Ablation under the Guidance of Relatively Low Ablation Index Values for Paroxysmal Atrial Fibrillation: Long-Term Outcomes and Characteristics of Recurrent Atrial Arrhythmias. J Clin Med 2023; 12:jcm12030971. [PMID: 36769620 PMCID: PMC9917927 DOI: 10.3390/jcm12030971] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2022] [Revised: 01/23/2023] [Accepted: 01/24/2023] [Indexed: 01/31/2023] Open
Abstract
OBJECTIVE The purpose of this study was to evaluate the difference in effectiveness and safety of high-power, short-duration (HPSD) radiofrequency catheter ablation (RFA) guided by relatively low ablation index (AI) values and conventional RFA in paroxysmal atrial fibrillation (PAF) patients. METHODS The HPSD RFA strategy (40-50 W, AI 350-400 for anterior, 320-350 for posterior wall; n = 547) was compared with the conventional RFA strategy (25-40 W, without AI; n = 396) in PAF patients who underwent their first ablation. Propensity-score matching analyses were used to compare the outcomes of the two groups while controlling for confounders. RESULTS After using propensity-score matching analysis, the HPSD group showed a higher early recurrence rate (22.727% vs. 13.636%, p = 0.003), similar late recurrence rate, and comparable safety (p = 0.604) compared with the conventional group. For late recurrent atrial arrhythmia types, the rate of regular atrial tachycardia was significantly higher in the HPSD group (p = 0.013). Additionally, the rate of chronic pulmonary vein reconnection and non-pulmonary vein triggers during repeat procedures was similar in both groups. CONCLUSIONS For PAF patients, compared with the conventional RFA strategy, the HPSD RFA strategy at relatively low AI settings had a higher early recurrence rate, similar long-term success rate, and comparable safety.
Collapse
Affiliation(s)
- Shuyu Jin
- The Second School of Clinical Medicine, Southern Medical University, Guangzhou 510515, China
- Guangdong Provincial People’s Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou 510080, China
| | - Weidong Lin
- Guangdong Provincial People’s Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou 510080, China
| | - Xianhong Fang
- Guangdong Provincial People’s Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou 510080, China
| | - Hongtao Liao
- Guangdong Provincial People’s Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou 510080, China
| | - Xianzhang Zhan
- Guangdong Provincial People’s Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou 510080, China
| | - Lu Fu
- Guangdong Provincial People’s Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou 510080, China
| | - Junrong Jiang
- Guangdong Provincial People’s Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou 510080, China
| | - Xingdong Ye
- Guangdong Provincial People’s Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou 510080, China
| | - Huiyi Liu
- Guangdong Provincial People’s Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou 510080, China
| | - Yanlin Chen
- Guangdong Provincial People’s Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou 510080, China
| | - Sijia Pu
- Guangdong Provincial People’s Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou 510080, China
- School of Medicine, South China University of Technology, Guangzhou 510006, China
| | - Shulin Wu
- Guangdong Provincial People’s Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou 510080, China
| | - Hai Deng
- The Second School of Clinical Medicine, Southern Medical University, Guangzhou 510515, China
- Guangdong Provincial People’s Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou 510080, China
- Correspondence: (H.D.); (Y.X.)
| | - Yumei Xue
- The Second School of Clinical Medicine, Southern Medical University, Guangzhou 510515, China
- Guangdong Provincial People’s Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou 510080, China
- Correspondence: (H.D.); (Y.X.)
| |
Collapse
|
10
|
Calvert P, Gupta D. Clinical outcomes with very high power very short duration ablation for atrial fibrillation: The jury is still out. J Cardiovasc Electrophysiol 2022; 33:2514-2516. [PMID: 36124386 DOI: 10.1111/jce.15679] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/13/2022] [Accepted: 09/15/2022] [Indexed: 12/15/2022]
Affiliation(s)
- Peter Calvert
- Liverpool Centre for Cardiovascular Science, University of Liverpool and Liverpool Heart & Chest Hospital Liverpool, Liverpool, UK
| | - Dhiraj Gupta
- Liverpool Centre for Cardiovascular Science, University of Liverpool and Liverpool Heart & Chest Hospital Liverpool, Liverpool, UK
| |
Collapse
|
11
|
Evolving Role of Catheter Ablation for Atrial Fibrillation: Early and Effective Rhythm Control. J Clin Med 2022; 11:jcm11226871. [PMID: 36431348 PMCID: PMC9696051 DOI: 10.3390/jcm11226871] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2022] [Revised: 11/11/2022] [Accepted: 11/17/2022] [Indexed: 11/23/2022] Open
Abstract
Catheter Ablation (CA) is an effective therapeutic option in treating atrial fibrillation (AF). Importantly, recent data show that CA as a rhythm control strategy not only significantly reduces AF burden, but also substantially improves clinical hard endpoints. Since AF is a progressive disease, the time of Diagnosis-to-Intervention appears crucial. Recent evidence shows that earlier rhythm control is associated with a lower risk of adverse cardiovascular outcomes in patients with early AF. Particularly, CA as an initial first line rhythm control strategy is associated with significant reduction of arrhythmia recurrence and rehospitalization in patients with paroxysmal AF. CA is shown to significantly lower the risk of progression from paroxysmal AF to persistent AF. When treating persistent AF, the overall clinical success after ablation remains unsatisfactory, however the ablation outcome in patients with "early" persistent AF appears better than those with "late" persistent AF. "Adjunctive" ablation on top of pulmonary vein isolation (PVI), e.g., ablation of atrial low voltage area, left atrial posterior wall, vein of Marshall, left atrial appendage, etc., may further reduce arrhythmia recurrence in selected patient group. New ablation concepts or new ablation technologies have been developing to optimize therapeutic effects or safety profile and may ultimately improve the clinical outcome.
Collapse
|
12
|
Comparison of Effectiveness and Safety between High-Power Short-Duration Ablation and Conventional Ablation for Atrial Fibrillation: A Systematic Review and Meta-Analysis. J Interv Cardiol 2022; 2022:6013474. [PMID: 36072362 PMCID: PMC9398879 DOI: 10.1155/2022/6013474] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2022] [Revised: 06/13/2022] [Accepted: 06/22/2022] [Indexed: 11/18/2022] Open
Abstract
Aim. We aimed to evaluate the effectiveness and safety between high-power short-duration (HPSD) radiofrequency ablation (RFA) and conventional RFA in patients with atrial fibrillation (AF). Methods. Studies comparing HPSD and traditional applications in patients undergoing initial catheter ablation for atrial fibrillation from inception through December 2021 were searched on Pubmed, Medline, Cochrane, and Clinicaltrials.gov. Results. The meta-analysis included seventeen studies with a total of 4934 patients. HPSD group decreased procedure duration (mean difference (MD) −38.28 min,
), RF duration (MD −20.51 min,
), fluoroscopy duration (MD −5.19 min,
), and acute pulmonary vein reconnection (Odds ratio (OR) 0.40,
), while improving the freedom from atrial arrhythmia at one year (OR 1.48, 95% confidence interval (CI) 1.12–1.94,
) and rates of first-pass isolation (OR 8.92,
). Compared with the conventional group, freedom from atrial arrhythmia at one-year follow-up was higher in the HPSD group without the guidance of AI/LSI (OR 1.66,
) and studies with a power setting of 40–50 W (OR 1.93,
). Nevertheless, the two groups had similar effectiveness with a power setting of 50 W in the HPSD RFA (OR 1.10,
). There was no difference in complications between the two groups (
). Conclusion. HPSD RFA was associated with shorter procedure duration, higher freedom from atrial arrhythmia, and comparable safety compared to conventional RFA.
Collapse
|
13
|
Ding WY, Tovmassian L, Bierme C, Kozhuharov N, Snowdon RL, Gupta D. Ablation index-guided 50W radiofrequency ablation for left atrial posterior wall isolation in atrial fibrillation. Indian Pacing Electrophysiol J 2022; 22:200-206. [PMID: 35642824 PMCID: PMC9263631 DOI: 10.1016/j.ipej.2022.05.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2022] [Revised: 04/11/2022] [Accepted: 05/23/2022] [Indexed: 11/03/2022] Open
Abstract
Background Ablation index (AI)-guided ablation for posterior wall isolation (PWI) using high-power, short-duration remains untested. We sought to evaluate the acute outcomes of AI-guided 50 W ablation vs. conventional ablation, and investigate the differences in relationship between contact force (CF), time and AI in both groups. Methods Consecutive patients undergoing first-time AI-guided ablation with PWI using either 50 W or 35–40 W ablation were enrolled. Acute procedural metrics and individual lesion level ablation data were compared between groups. Results 40 patients (50 W: n = 20, 35–40 W: n = 20) with atrial fibrillation were included. Total procedure time was significantly reduced with 50 W (120 vs. 143 mins, p = 0.004) and there was a trend toward decreased ablation time (22 vs. 28 mins, p = 0.052). First pass and acute success of PWI were comparable between the 50 W and 35–40 W groups (10 vs. 8 patients, p = 0.525 and 20 vs. 19 patients, p = 1.000, respectively). Individual lesion analysis of all 959 RF applications (50 W: n = 458, 35–40 W: n = 501) demonstrated that 50 W ablation led to lower ablation time per lesion (10.4 vs. 13.0s, p < 0.001), and increased AI (471 vs. 461, p < 0.001) and impedance drop (7.4 vs. 6.9ohms, p = 0.007). Excessive ablations (AI>600 for roof line; AI>500 elsewhere) were more frequently observed in the 50 W group (9.0% vs. 4.6%, p = 0.007). CF had very good discriminative capability for excessive ablation in both groups. At 50 W, limiting the CF to <10 g reduced the number of excessive ablations on the floor line and within the posterior box to 12% and 4%,respectively. Recurrence of atrial arrhythmias at 12 months were comparable between the groups. Conclusion AI-guided 50 W RF ablation reduces the ablation time of individual lesions and total procedure time without compromising first pass and acute success rates of PWI or 12-month outcomes compared to conventional powers.
Collapse
|
14
|
Cai C, Wang J, Niu HX, Chu JM, Hua W, Zhang S, Yao Y. Optimal Lesion Size Index for Pulmonary Vein Isolation in High-Power Radiofrequency Catheter Ablation of Atrial Fibrillation. Front Cardiovasc Med 2022; 9:869254. [PMID: 35463774 PMCID: PMC9021528 DOI: 10.3389/fcvm.2022.869254] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2022] [Accepted: 03/14/2022] [Indexed: 11/13/2022] Open
Abstract
Background Although both high-power (HP) ablation and lesion size index (LSI) are novel approaches to make effective lesions during pulmonary vein isolation (PVI) for atrial fibrillation (AF), the optimal LSI in HP ablation for PVI is still unclear. Our study sought to explore the association between LSI and acute conduction gap formation and investigate the optimal LSI in HP ablation for PVI. Methods A total of 105 consecutive patients with AF who underwent HP ablation guided by LSI (LSI-guided HP) for PVI in our institute between June 2019 and July 2020 were retrospectively enrolled. Each ipsilateral PV circle was subdivided into four segments, and ablation power was set to 50 W with target LSI values at 5.0 and 4.0 for anterior and posterior walls, respectively. We compared the LSI values with and without acute conduction gaps after the initial first-pass PVI. Results PVI was achieved in all patients, and the incidence of first-pass PVI was 78.1% (82/105). A total of 6,842 lesion sites were analyzed, and the acute conduction gaps were observed in 23 patients (21.9%) with 45 (0.7%) lesion points. The gap formation was significantly associated with lower LSI (3.9 ± 0.4 vs. 4.6 ± 0.4, p < 0.001), lower force-time integral (82.6 ± 24.6 vs. 120.9 ± 40.4 gs, p < 0.001), lower mean contact force (5.7 ± 2.4 vs. 8.5 ± 2.8 g, p < 0.001), shorter ablation duration (10.5 ± 3.6 vs. 15.4 ± 6.4 s, p < 0.001), lower mean temperature (34.4 ± 1.4 vs. 35.6 ± 2.6°C, p < 0.001), and longer interlesion distance (4.4 ± 0.3 vs. 4.3 ± 0.4 mm, p = 0.031). As per the receiver operating characteristic analysis, the LSI had the highest predictive value for gap formation in all PVs segments, with a cutoff of 4.35 for effective ablation (sensitivity 80.0%; specificity 75.4%, areas under the curve: 0.87). The LSI of 4.55 and 3.95 had the highest predictive value for gap formation for the anterior and posterior segments of PVs, respectively. Conclusion Using LSI-guided HP ablation for PVI, more than 4.35 of LSI for all PVs segments showed the best predictive value to avoid gap formation for achieving effective first-pass PVI. The LSI of 4.55 for the anterior wall and 3.95 for the posterior wall were the best cutoff values for predicting gap formation, respectively.
Collapse
Affiliation(s)
- Chi Cai
- Cardiac Arrhythmia Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences, Peking Union Medical College, Beijing, China
| | - Jing Wang
- Cardiac Arrhythmia Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences, Peking Union Medical College, Beijing, China
| | - Hong-Xia Niu
- Cardiac Arrhythmia Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences, Peking Union Medical College, Beijing, China
| | - Jian-Min Chu
- Cardiac Arrhythmia Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences, Peking Union Medical College, Beijing, China
| | - Wei Hua
- Cardiac Arrhythmia Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences, Peking Union Medical College, Beijing, China
| | - Shu Zhang
- Cardiac Arrhythmia Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences, Peking Union Medical College, Beijing, China
| | - Yan Yao
- Cardiac Arrhythmia Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences, Peking Union Medical College, Beijing, China
| |
Collapse
|
15
|
Mirror mirror on the wall: Which is the best ablation index of all? Indian Pacing Electrophysiol J 2022; 22:68-69. [PMID: 35272854 PMCID: PMC8981137 DOI: 10.1016/j.ipej.2022.02.019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
|
16
|
Tomlinson DR, Mandrola J. Radiofrequency ablation data associated with atrioesophageal fistula. HeartRhythm Case Rep 2022; 7:781-790. [PMID: 34987959 PMCID: PMC8695297 DOI: 10.1016/j.hrcr.2021.09.012] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/03/2022] Open
Affiliation(s)
- David R. Tomlinson
- University Hospitals Plymouth NHS Trust, South West Cardiothoracic Centre, Derriford Hospital, Plymouth, United Kingdom
- Address reprint requests and correspondence: David R. Tomlinson, University Hospitals Plymouth NHS Trust, South West Cardiothoracic Centre, Derriford Hospital, Derriford Rd, Plymouth, PL6 8DH, UK.
| | | |
Collapse
|
17
|
Okamatsu H, Okumura K, Kaneko S, Negishi K, Hayashi K, Tsurugi T, Tanaka Y, Nakao K, Sakamoto T, Koyama J. Ablation Index-Guided High-Power Radiofrequency Application Shortens the Procedure Time With Similar Outcomes to Conventional Power Application in Atrial Fibrillation Ablation. Circ Rep 2021; 3:559-568. [PMID: 34703933 PMCID: PMC8492404 DOI: 10.1253/circrep.cr-21-0099] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2021] [Accepted: 07/18/2021] [Indexed: 11/21/2022] Open
Abstract
Background:
The impact of high-power radiofrequency (RF) application in ablation index (AI)-guided atrial fibrillation (AF) ablation has not been elucidated. Methods and Results:
We investigated 1,333 patients undergoing first AF ablation (median age 68 years; interquartile range [IQR] 61–73 years). The first 301 patients underwent AI-guided conventional power RF application (CP group), whereas the following 1,032 patients underwent high-power RF application (HP group). The minimum AI target values were 400, 360, and 260 at the left atrial anterior wall, posterior wall, and esophagus, respectively. RF power in the CP group was 30–40, 20–25, and 20 W at the anterior wall, posterior wall, and esophagus, respectively, compared with 50, 40, and 25, respectively, in the HP group. Procedure time was shorter in the HP than CP group (median 153 [IQR 129–190] vs. 180 (IQR 152–229) min; P<0.0001). The percentage of first-pass pulmonary vein isolation (69% vs. 73%; P=0.07) and all procedure-related complications (2.0% vs. 3.4%; P=0.19) was similar. Kaplan-Meier analysis showed similar recurrence-free survival (RFS) for all AF types. Respective 1-year RFS in the CP and HP groups was 82% and 87% in paroxysmal AF, 78% and 82% in persistent AF, and 59% and 58% in long-standing persistent AF. Conclusions:
In AI-guided AF ablation, high-power RF application shortens the procedure time without increasing complications and with similar outcomes.
Collapse
Affiliation(s)
- Hideharu Okamatsu
- Division of Cardiology, Saiseikai Kumamoto Hospital Cardiovascular Center Kumamoto Japan
| | - Ken Okumura
- Division of Cardiology, Saiseikai Kumamoto Hospital Cardiovascular Center Kumamoto Japan
| | - Shozo Kaneko
- Division of Cardiology, Saiseikai Kumamoto Hospital Cardiovascular Center Kumamoto Japan
| | - Kodai Negishi
- Division of Cardiology, Saiseikai Kumamoto Hospital Cardiovascular Center Kumamoto Japan
| | - Katsuhide Hayashi
- Division of Cardiology, Saiseikai Kumamoto Hospital Cardiovascular Center Kumamoto Japan
| | - Takuo Tsurugi
- Division of Cardiology, Saiseikai Kumamoto Hospital Cardiovascular Center Kumamoto Japan
| | - Yasuaki Tanaka
- Division of Cardiology, Saiseikai Kumamoto Hospital Cardiovascular Center Kumamoto Japan
| | - Koichi Nakao
- Division of Cardiology, Saiseikai Kumamoto Hospital Cardiovascular Center Kumamoto Japan
| | - Tomohiro Sakamoto
- Division of Cardiology, Saiseikai Kumamoto Hospital Cardiovascular Center Kumamoto Japan
| | - Junjiroh Koyama
- Division of Cardiology, Saiseikai Kumamoto Hospital Cardiovascular Center Kumamoto Japan
| |
Collapse
|