Reichlin T, Kueffer T, Knecht S, Madaffari A, Badertscher P, Maurhofer J, Krisai P, Jufer C, Asatryan B, Heg D, Servatius H, Tanner H, Kühne M, Roten L, Sticherling C. PolarX vs Arctic Front for Cryoballoon Ablation of Paroxysmal AF: The Randomized COMPARE CRYO Study. JACC Clin Electrophysiol 2024; 10:1367-1376. [PMID: 38752963 DOI: 10.1016/j.jacep.2024.03.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2023] [Revised: 03/04/2024] [Accepted: 03/22/2024] [Indexed: 07/26/2024]
Abstract
BACKGROUND Pulmonary vein isolation is an effective treatment for atrial fibrillation (AF). Cryoballoon ablation using the Arctic Front cryoballoon (Medtronic) was found to be superior to antiarrhythmic drug treatment. Recently, a novel cryoballoon system was introduced (PolarX, Boston Scientific). OBJECTIVES The purpose of this study was to compare the efficacy and safety of the 2 cryoballoons in a randomized controlled trial. METHODS Patients with symptomatic paroxysmal AF were enrolled in 2 centers and randomized 1:1 to pulmonary vein isolation using the PolarX or the Arctic Front cryoballoon. All patients received an implantable cardiac monitor. The primary endpoint was first recurrence of atrial tachyarrhythmia (AF, atrial flutter, or atrial tachycardia [AT]) between days 91 and 365. Procedural safety was assessed by a composite of tamponade, phrenic nerve palsy lasting >24 hours, vascular complications, stroke/transient ischemic attack, atrioesophageal fistula or death up to 30 days. RESULTS A total of 201 patients were enrolled. At 1 year, recurrence of atrial tachyarrhythmia had occurred in 41 of 99 patients (41.6%) assigned to the PolarX group and in 48 of 102 patients (47.1%) assigned to the Arctic Front group (HR: 0.85 [95% CI: 0.56-1.30]; P = 0.03 for noninferiority; P = 0.46 for superiority). The safety endpoint occurred in 5 patients (5%) in the PolarX group (n = 5 phrenic nerve palsies lasting >24 hours), whereas no safety endpoints occurred in the Arctic Front group (P = 0.03). CONCLUSIONS In this randomized controlled trial using implantable cardiac monitors for continuous rhythm monitoring, the novel PolarX cryoballoon was noninferior compared with the Arctic Front cryoballoon regarding efficacy. However, the PolarX balloon resulted in significantly more phrenic nerve palsies. (Comparison of PolarX and the Arctic Front Cryoballoons for PVI in Patients With Symptomatic Paroxysmal AF [COMPARE-CRYO]; NCT04704986).
Collapse
Affiliation(s)
- Tobias Reichlin
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
| | - Thomas Kueffer
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Sven Knecht
- Department of Cardiology, University Hospital Basel, University of Basel, Basel, Switzerland
| | - Antonio Madaffari
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Patrick Badertscher
- Department of Cardiology, University Hospital Basel, University of Basel, Basel, Switzerland
| | - Jens Maurhofer
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Philipp Krisai
- Department of Cardiology, University Hospital Basel, University of Basel, Basel, Switzerland
| | - Corinne Jufer
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Babken Asatryan
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland; Division of Cardiology, Department of Medicine, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Dik Heg
- CTU Bern, University of Bern, Bern, Switzerland
| | - Helge Servatius
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Hildegard Tanner
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Michael Kühne
- Department of Cardiology, University Hospital Basel, University of Basel, Basel, Switzerland
| | - Laurent Roten
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Christian Sticherling
- Department of Cardiology, University Hospital Basel, University of Basel, Basel, Switzerland
| |
Collapse
|
2
|
Bai R, Liao Y, Wang X, Rosenthal K, Vessey J, Mazor M, Su W. In vivo safety and pulmonary vein isolation performance of a new cryoballoon for the treatment of atrial fibrillation. J Interv Card Electrophysiol 2024:10.1007/s10840-024-01836-5. [PMID: 38831168 DOI: 10.1007/s10840-024-01836-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/11/2024] [Accepted: 05/23/2024] [Indexed: 06/05/2024]
Abstract
BACKGROUND Cryoablation to achieve pulmonary vein (PV) isolation has become one of the standard approaches for atrial fibrillation (AF) ablation. The Arctic Front series cryoballoon and Achieve circular mapping catheter (Medtronic) inherently possess design defects that have been associated with unfavorite clinical outcomes. Lately, a new cryoablation system (Nordica Cryoablation System, Synaptic Medical) was developed with improved design of the cryoballoon and circular mapping catheter to address the inadequacies of current cryoablation technology. An animal study was conducted to test the efficacy and safety in performing PVI with the Nordica Cryoablation System. METHODS Pulmonary vein isolation with the Nordica Cryoablation System was performed on 12 PVs of six healthy canines. Acute PVI and peri-procedural complications were recorded. All animals underwent a repeat EP study at least 4 weeks after index procedures followed by pathological and histological assessments of the heart and collateral/downstream organs after planned euthanasia. RESULTS Acute PV isolation was achieved in all targeted PVs with 50% of PVs being isolated with a single cryoablation application. There were no major peri-procedural complications or device malfunction events. All PVs remained isolated after 29-30 days follow-up. Histological examination showed transmural cryo-lesions at treated sites with minimal inflammation, neovascularization, and neointima formation but no significant injury to adjacent tissue or embolization in downstream organs. CONCLUSION Acute and durable PVI can be achieved by using the novel Nordica Cryoablation System. Ablation with this new cryoablation system is associated with transmural lesions at targeted myocardium but creates no injury to the collateral tissues or downstream organs.
Collapse
Affiliation(s)
- Rong Bai
- Division of Cardiology, Banner-University Medicine Heart Institute, Banner University Medical Center-Phoenix, College of Medicine, University of Arizona, 755. E McDowell Road, Floor 4, Phoenix, 85006, AZ, USA.
| | - Yu Liao
- Department of Internal Medicine, Division of Cardiology, National Cheng Kung University Hospital, Tainan, Taiwan
| | - Xunzhang Wang
- Department of Cardiology, Smidt Heart Institute, Cedars-Sinai, Los Angeles, CA, USA
| | | | | | | | - Wilber Su
- Division of Cardiology, Banner-University Medicine Heart Institute, Banner University Medical Center-Phoenix, College of Medicine, University of Arizona, 755. E McDowell Road, Floor 4, Phoenix, 85006, AZ, USA.
| |
Collapse
|
3
|
Katov L, Teumer Y, Bothner C, Rottbauer W, Weinmann-Emhardt K. Pulmonary Vein Isolation with Pulsed Field Ablation and Size-Adjustable Cryo-Balloon: A Comparative Procedural Analysis of First-Time Use. J Clin Med 2024; 13:3113. [PMID: 38892824 PMCID: PMC11172636 DOI: 10.3390/jcm13113113] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2024] [Revised: 05/19/2024] [Accepted: 05/22/2024] [Indexed: 06/21/2024] Open
Abstract
Background: Pulmonary vein isolation (PVI) is the standard of care for the treatment of symptomatic atrial fibrillation (AF). Novel techniques for PVI are the thermal size-adjustable cryo-balloon (CB) system and non-thermal pulsed field ablation (PFA) system. There are currently no data available for a direct comparison between these two systems. Furthermore, with new techniques, it is important to ensure a high level of efficiency and safety during treatment right from initial use. Therefore, the aim of this study was to directly compare the procedural data and safety of these two new PVI techniques in first-time users. Methods: We conducted a single-center prospective study involving 100 consecutive patients with symptomatic atrial fibrillation who underwent first-time PVI using either size-adjustable CB PVI or PFA PVI from July 2023 to March 2024. Results: Acute PVI was achieved in 100% of patients in both groups. First-pass isolation (FPI) was more frequently achieved in the PFA group compared to the size-adjustable CB group. The mean procedural duration and fluoroscopy dose were significantly shorter in the PFA cohort (p < 0.001). Furthermore, a significant reduction in fluoroscopy time was observed during the learning curve within the PFA group (p = 0.023). There were no major complications in both groups. Conclusions: Both systems demonstrate good effectiveness and safety during PVI performed by first-time users. However, the PFA group exhibited a significantly shorter procedural duration.
Collapse
Affiliation(s)
| | | | | | | | - Karolina Weinmann-Emhardt
- Department of Cardiology, Ulm University Heart Center, Albert-Einstein-Allee 23, 89081 Ulm, Germany (Y.T.)
| |
Collapse
|
4
|
Sciacca V, Fink T, Winnik S, Hamriti ME, Guckel D, Didenko M, Mörsdorf M, Braun M, Khalaph M, Imnadze G, Sommer P, Sohns C. Pressure waveform analysis for occlusion assessment significantly reduces contrast medium use in cryoballoon pulmonary vein isolation. J Interv Card Electrophysiol 2024:10.1007/s10840-024-01801-2. [PMID: 38632135 DOI: 10.1007/s10840-024-01801-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/22/2024] [Accepted: 03/28/2024] [Indexed: 04/19/2024]
Abstract
BACKGROUND Pulmonary vein (PV) occlusion is crucial for adequate lesion formation during cryoballoon-guided pulmonary vein isolation (CB-PVI). PV occlusion is usually confirmed by angiographies over the inflated balloon device. The aim of our study was to analyze the safety and efficacy of pressure waveform-based PV occlusion assessment during CB-PVI utilizing a novel fully integrated pressure analysis tool. METHODS Consecutive patients with symptomatic atrial fibrillation (AF) scheduled for CB-PVI were prospectively enrolled for pressure waveform-based PV occlusion assessment. A patient cohort receiving conventional angiographies served as control group. Patients with common PV ostia were excluded. RESULTS The study group consisted of 40 patients (16 females, mean age was 64.5 ± 9.7, 45% persistent AF). The control group consisted of 40 matched patients. All 160 PVs in the study group were successfully isolated without the use of additional venograms confirming PV occlusion. The mean procedure duration was 69 ± 12 min in the study group with a mean fluoroscopy duration of 11.5 ± 4.4 min. The mean contrast medium volume was 22 ± 9 ml in the study group and 36 ± 12 ml in the control group (p = 0.0001). Mean procedure duration, mean balloon temperatures, and mean ablation application durations did not differ significantly between the study and the control group. No periprocedural complications occurred. CONCLUSION CB-PVI utilizing a fully integrated pressure waveform analysis tool to assess PV occlusion is feasible and safe and significantly reduces the amount of contrast medium without impact on procedural parameters and freedom from arrhythmia recurrence.
Collapse
Affiliation(s)
- Vanessa Sciacca
- Clinic for Electrophysiology, Herz- und Diabeteszentrum NRW, Ruhr-Universität Bochum, Med. Fakultät OWL (Universität Bielefeld), Georgstr. 11, 32545, Bad Oeynhausen, Germany.
| | - Thomas Fink
- Clinic for Electrophysiology, Herz- und Diabeteszentrum NRW, Ruhr-Universität Bochum, Med. Fakultät OWL (Universität Bielefeld), Georgstr. 11, 32545, Bad Oeynhausen, Germany
| | - Stephan Winnik
- Clinic for Cardiology and Angiology, GZO Spital Wetzikon, Wetzikon, Zürich, Switzerland
| | - Mustapha El Hamriti
- Clinic for Electrophysiology, Herz- und Diabeteszentrum NRW, Ruhr-Universität Bochum, Med. Fakultät OWL (Universität Bielefeld), Georgstr. 11, 32545, Bad Oeynhausen, Germany
| | - Denise Guckel
- Clinic for Electrophysiology, Herz- und Diabeteszentrum NRW, Ruhr-Universität Bochum, Med. Fakultät OWL (Universität Bielefeld), Georgstr. 11, 32545, Bad Oeynhausen, Germany
| | - Maxim Didenko
- Clinic for Electrophysiology, Herz- und Diabeteszentrum NRW, Ruhr-Universität Bochum, Med. Fakultät OWL (Universität Bielefeld), Georgstr. 11, 32545, Bad Oeynhausen, Germany
| | - Maximilian Mörsdorf
- Clinic for Electrophysiology, Herz- und Diabeteszentrum NRW, Ruhr-Universität Bochum, Med. Fakultät OWL (Universität Bielefeld), Georgstr. 11, 32545, Bad Oeynhausen, Germany
| | - Martin Braun
- Clinic for Electrophysiology, Herz- und Diabeteszentrum NRW, Ruhr-Universität Bochum, Med. Fakultät OWL (Universität Bielefeld), Georgstr. 11, 32545, Bad Oeynhausen, Germany
| | - Moneeb Khalaph
- Clinic for Electrophysiology, Herz- und Diabeteszentrum NRW, Ruhr-Universität Bochum, Med. Fakultät OWL (Universität Bielefeld), Georgstr. 11, 32545, Bad Oeynhausen, Germany
| | - Guram Imnadze
- Clinic for Electrophysiology, Herz- und Diabeteszentrum NRW, Ruhr-Universität Bochum, Med. Fakultät OWL (Universität Bielefeld), Georgstr. 11, 32545, Bad Oeynhausen, Germany
| | - Philipp Sommer
- Clinic for Electrophysiology, Herz- und Diabeteszentrum NRW, Ruhr-Universität Bochum, Med. Fakultät OWL (Universität Bielefeld), Georgstr. 11, 32545, Bad Oeynhausen, Germany
| | - Christian Sohns
- Clinic for Electrophysiology, Herz- und Diabeteszentrum NRW, Ruhr-Universität Bochum, Med. Fakultät OWL (Universität Bielefeld), Georgstr. 11, 32545, Bad Oeynhausen, Germany.
| |
Collapse
|
5
|
Ellenbogen KA, Mittal S, Varma N, Aryana A, Marrouche N, Anić A, Nair D, Champagne J, Iacopino S, de Asmundis C, Weiner S, Makati K, Raybuck JD, Richards E, Su W. One-year outcomes of pulmonary vein isolation with a novel cryoballoon: Primary results of the FROZEN AF trial. J Cardiovasc Electrophysiol 2024; 35:832-842. [PMID: 38448797 DOI: 10.1111/jce.16220] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/09/2024] [Revised: 01/27/2024] [Accepted: 02/05/2024] [Indexed: 03/08/2024]
Abstract
INTRODUCTION Cryoablation therapy for pulmonary vein isolation (PVI) to treat paroxysmal atrial fibrillation (PAF) is well established. A novel 28 mm cryoballoon system designed to operate under low pressure to safely reach a lower nadir temperature and maintain constant balloon size during cooling has not been prospectively studied in a large patient population for safety and efficacy. The FROZEN AF (NCT04133168) trial was an international multicenter, open-label, prospective, single-arm study on the safety and performance of a novel cryoballoon system for treatment of PAF. METHODS AND RESULTS The study enrolled patients at 44 sites in 10 countries across North America, Europe, and Asia. Subjects were indicated for PVI treatment of PAF and had failed or were intolerant of one or more antiarrhythmic drugs. Procedural outcomes were defined based on the 2017 HRS consensus statement. Follow-up was performed at 7 days, 3, 6, and 12 months. Data are reported as mean ± SD or median (IQR). PVI was performed with a 28 mm cryoballoon in 325 drug refractory PAF patients. Complete PVI was achieved in 95.7% of patients. In cryoablation lesions longer than 60 s, 60.1% of PV isolations required only a single cryoballoon application. Procedure related complications included: phrenic nerve palsy [temporary 4 (1.2%), persistent 0 (0.0%)], cardiac tamponade/perforation 2 (0.6%), and air embolism 1 (0.3%). Freedom from documented atrial arrhythmia recurrence at 12 months was 79.9% (AF 82.7%, AFL 96.5%, AT 98.1%), antiarrhythmic drugs (AAD) were continued or re-initiated in 26.8% of patients after the 3-month blanking period. Additionally, an extension arm enrolled 50 pts for treatment with 28/31 mm variable size cryoballoon. A single temporary PNP occurred in this group, which resolved before discharge. Freedom from documented recurrence at 12 months in these pts was 82.0%. CONCLUSIONS This novel cryoballoon may facilitate PVI to treat PAF, providing more options to address the variety of anatomies present in patients with PAF. This cryoballoon system proved to be safe and effective for treatment of patients with drug refractory or drug intolerant PAF.
Collapse
Affiliation(s)
- Kenneth A Ellenbogen
- Division of Cardiology, Virginian Commonwealth University, Richmond, Virginia, USA
| | | | | | - Arash Aryana
- Mercy General Hospital, Sacramento, California, USA
| | - Nassir Marrouche
- Tulane University School of Medicine, New Orleans, Louisiana, USA
| | - Ante Anić
- University Hospital Split, Split, Croatia
| | - Devi Nair
- Arrhythmia Research Group, Jonesboro, Arkansas, USA
| | - Jean Champagne
- Institut Universitaire de Cardiologie et de Pneumologie de Quebec, Quebec, Canada
| | | | | | - Stanislav Weiner
- Christus Trinity Mother Frances Health System, Tyler, Texas, USA
| | | | | | | | - Wilber Su
- Banner University Medical Center, Phoenix, Arizona, USA
| |
Collapse
|
6
|
Tachibana S, Miyazaki S, Nitta J, Shirai Y, Nagata Y, Sagawa Y, Sekiguchi Y, Inamura Y, Sasaki T, Yamauchi Y, Inaba O, Ono Y, Suzuki M, Suzuki A, Iwai S, Okada H, Mizukami A, Azegami K, Hachiya H, Handa K, Goto K, Nishimura T, Hirao K, Takahashi A, Sasano T. Incidence of phrenic nerve injury during pulmonary vein isolation using different cryoballoons: data from a large prospective ablation registry. Europace 2024; 26:euae092. [PMID: 38588039 PMCID: PMC11057019 DOI: 10.1093/europace/euae092] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2024] [Accepted: 04/02/2024] [Indexed: 04/10/2024] Open
Abstract
AIMS Phrenic nerve injury (PNI) is the most common complication during cryoballoon ablation. Currently, two cryoballoon systems are available, yet the difference is unclear. We sought to compare the acute procedural efficacy and safety of the two cryoballoons. METHODS This prospective observational study consisted of 2,555 consecutive atrial fibrillation (AF) patients undergoing pulmonary vein isolation (PVI) using either conventional (Arctic Front Advance) (AFA-CB) or novel cryoballoons (POLARx) (POLARx-CB) at 19 centers between January 2022 and October 2023. RESULTS Among 2,555 patients (68.8 ± 10.9 years, 1,740 men, paroxysmal AF[PAF] 1,670 patients), PVIs were performed by the AFA-CB and POLARx-CB in 1,358 and 1,197 patients, respectively. Touch-up ablation was required in 299(11.7%) patients. The touch-up rate was significantly lower for POLARx-CB than AFA-CB (9.5% vs. 13.6%, p = 0.002), especially for right inferior PVs (RIPVs). The touch-up rate was significantly lower for PAF than non-PAF (8.8% vs. 17.2%, P < 0.001) and was similar between the two cryoballoons in non-PAF patients. Right PNI occurred in 64(2.5%) patients and 22(0.9%) were symptomatic. It occurred during the right superior PV (RSPV) ablation in 39(1.5%) patients. The incidence was significantly higher for POLARx-CB than AFA-CB (3.8% vs. 1.3%, P < 0.001) as was the incidence of symptomatic PNI (1.7% vs. 0.1%, P < 0.001). The difference was significant during RSPV (2.5% vs. 0.7%, P < 0.001) but not RIPV ablation. The PNI recovered more quickly for the AFA-CB than POLARx-CB. CONCLUSIONS Our study demonstrated a significantly higher incidence of right PNI and lower touch-up rate for the POLARx-CB than AFA-CB in the real-world clinical practice.
Collapse
Affiliation(s)
- Shinichi Tachibana
- Department of Cardiology, Japanese Red Cross Saitama Hospital, Saitama, Japan
| | - Shinsuke Miyazaki
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University, Yushima 1-5-45, Bunkyo-ku, Tokyo 113-8510, Japan
| | - Junichi Nitta
- Department of Cardiology, Sakakibara Heart Institute, Tokyo, Japan
| | - Yasuhiro Shirai
- Department of Cardiology, Disaster Medical Center, Tokyo, Japan
| | - Yasutoshi Nagata
- Department of Cardiology, Japanese Red Cross Musashino Hospital, Tokyo, Japan
| | - Yuichiro Sagawa
- Department of Cardiology, Japanese Red Cross Yokohama City Bay Hospital, Kanagawa, Japan
| | - Yukio Sekiguchi
- Department of Cardiology, Sakakibara Heart Institute, Tokyo, Japan
| | - Yukihiro Inamura
- Department of Cardiology, Japanese Red Cross Saitama Hospital, Saitama, Japan
| | - Takeshi Sasaki
- Department of Cardiology, Disaster Medical Center, Tokyo, Japan
| | - Yasuteru Yamauchi
- Department of Cardiology, Japanese Red Cross Yokohama City Bay Hospital, Kanagawa, Japan
| | - Osamu Inaba
- Department of Cardiology, Japanese Red Cross Saitama Hospital, Saitama, Japan
| | - Yuichi Ono
- Department of Cardiology, Ome Municipal General Hospital, Tokyo, Japan
| | - Makoto Suzuki
- Department of Cardiology, Yokohama Minami Kyosai Hospital, Kanagawa, Japan
| | | | - Shinsuke Iwai
- Department of Cardiology, Hiratsuka Kyosai Hospital, Kanagawa, Japan
| | - Hiroyuki Okada
- Department of Cardiology, Soka Municipal Hospital, Saitama, Japan
| | - Akira Mizukami
- Department of Cardiology, Kameda Medical Center, Chiba, Japan
| | - Koji Azegami
- Department of Cardiology, Shin-Yurigaoka General Hospital, Kanagawa, Japan
| | - Hitoshi Hachiya
- Cardiovascular Center, Tsuchiura Kyodo Hospital, Ibaraki, Japan
| | - Keita Handa
- Division of Cardiology, Kashiwa City Hospital, Chiba, Japan
| | - Kentaro Goto
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University, Yushima 1-5-45, Bunkyo-ku, Tokyo 113-8510, Japan
| | - Takuro Nishimura
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University, Yushima 1-5-45, Bunkyo-ku, Tokyo 113-8510, Japan
| | - Kenzo Hirao
- Arrhythmia Advanced Therapy Center, AOI Universal Hospital, Kanagawa, Japan
| | | | - Tetsuo Sasano
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University, Yushima 1-5-45, Bunkyo-ku, Tokyo 113-8510, Japan
| |
Collapse
|
7
|
Frommeyer G, Ellermann C, Wolfes J, Lange PS, Güner F, Eckardt L. Feasibility and efficacy of a novel size adjustable cryoballoon for ablation of atrial fibrillation. J Interv Card Electrophysiol 2024; 67:253-255. [PMID: 37715834 PMCID: PMC10902017 DOI: 10.1007/s10840-023-01645-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/14/2023] [Accepted: 09/10/2023] [Indexed: 09/18/2023]
Abstract
The aim of the present case series was to characterize the feasibility of a novel size adjustable cryoballoon system (PolarX Fit, Boston Scientific, Marlborough, MA, USA). This cryoballoon catheter can be inflated to two different diameters (28 mm and 31 mm) within the same procedure allowing vein adapted PVI. In summary, the novel size adjustable cryoballoon shows similar characteristics as the established versions. The intraprocedural flexibility of balloon size led to employment of the larger variant in the majority of freeze applications. Of note, in all but one procedure, both sizes were employed to ensure optimal occlusion for all veins. This initial series suggests that the size adjustable balloon offers more flexibility of obtain optimal occlusions in particular, in challenging anatomies, including common pulmonary vein ostia.
Collapse
Affiliation(s)
- Gerrit Frommeyer
- Department of Cardiology II-Electrophysiology, University Hospital Münster, Albert-Schweitzer-Campus 1, Gebäude A1, 48149, Münster, Germany.
| | - Christian Ellermann
- Department of Cardiology II-Electrophysiology, University Hospital Münster, Albert-Schweitzer-Campus 1, Gebäude A1, 48149, Münster, Germany
| | - Julian Wolfes
- Department of Cardiology II-Electrophysiology, University Hospital Münster, Albert-Schweitzer-Campus 1, Gebäude A1, 48149, Münster, Germany
| | - Philipp S Lange
- Department of Cardiology II-Electrophysiology, University Hospital Münster, Albert-Schweitzer-Campus 1, Gebäude A1, 48149, Münster, Germany
| | - Fatih Güner
- Department of Cardiology II-Electrophysiology, University Hospital Münster, Albert-Schweitzer-Campus 1, Gebäude A1, 48149, Münster, Germany
| | - Lars Eckardt
- Department of Cardiology II-Electrophysiology, University Hospital Münster, Albert-Schweitzer-Campus 1, Gebäude A1, 48149, Münster, Germany
| |
Collapse
|
8
|
Kanthasamy V, Schilling R, Zongo O, Khan K, Earley M, Monk V, Hunter R, Mangiafico V, Ang R, Creta A, Aluwhalia N, Honarbakhsh S, Dhinoja M, Gupta D, Finlay M. Feasibility of double-blinded, placebo-controlled interventional study for assessing catheter ablation efficacy in persistent atrial fibrillation: Insights from the ORBITA AF feasibility study. Am Heart J 2024; 269:56-71. [PMID: 38109985 DOI: 10.1016/j.ahj.2023.12.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/29/2023] [Revised: 11/28/2023] [Accepted: 12/11/2023] [Indexed: 12/20/2023]
Abstract
BACKGROUND To date, there are no randomized, double-blinded clinical trials comparing catheter ablation to DC cardioversion (DCCV) with medical therapy in patients with persistent atrial fibrillation (PersAF). Conducting a large-scale trial to address this question presents considerable challenges, including recruitment, blinding, and implementation. We conducted a pilot study to evaluate the feasibility of conducting a definitive placebo-controlled trial. METHODS This prospective trial was carried out at Barts Heart Centre, United Kingdom, employing a randomized, double-blinded, placebo-controlled design. Twenty patients with PersAF (duration <2 years) were recruited, representing 10% of the proposed larger trial as determined by a power calculation. The patients were randomized in a 1:1 ratio to receive either PVI ± DCCV (PVI group) or DCCV + Placebo (DCCV group). The primary endpoint of this feasibility study was to evaluate patient blinding. Patients remained unaware of their treatment allocation until end of study. RESULTS During the study, 35% of patients experienced recurrence of PersAF prior to completion of 12 months follow-up. Blinding was successfully maintained amongst both patients and medical staff. The DCCV group had a trend to higher recurrence and repeat procedure rate compared to the PVI group (recurrence of PersAF 60% vs 30%; p = .07 and repeat procedure 70% vs 40%; p = .4). The quality of life experienced by individuals in the PVI group showed improvement, as evidenced by enhanced scores on the AF specific questionnaire (AF PROMS) (3 [±4] vs 21 [±8]) and SF-12 mental-component raw score (51.4 [±7] vs 43.24 [±15]) in patients who maintained sinus rhythm at 12 months. CONCLUSION This feasibility study establishes the potential for conducting a blinded, placebo-controlled trial to evaluate the efficacy of PVI versus DCCV in patients with PersAF.
Collapse
Affiliation(s)
- Vijayabharathy Kanthasamy
- Barts Heart Centre, Barts Health National Health Service Trust, London, United Kingdom; William Harvey Research Institute, Queen Mary University of London, London, United Kingdom
| | - Richard Schilling
- Barts Heart Centre, Barts Health National Health Service Trust, London, United Kingdom; William Harvey Research Institute, Queen Mary University of London, London, United Kingdom
| | - Olivier Zongo
- William Harvey Research Institute, Queen Mary University of London, London, United Kingdom
| | - Kamran Khan
- William Harvey Research Institute, Queen Mary University of London, London, United Kingdom
| | - Mark Earley
- Barts Heart Centre, Barts Health National Health Service Trust, London, United Kingdom
| | - Vivienne Monk
- William Harvey Research Institute, Queen Mary University of London, London, United Kingdom
| | - Ross Hunter
- Barts Heart Centre, Barts Health National Health Service Trust, London, United Kingdom; William Harvey Research Institute, Queen Mary University of London, London, United Kingdom
| | - Valentina Mangiafico
- Barts Heart Centre, Barts Health National Health Service Trust, London, United Kingdom
| | - Richard Ang
- Barts Heart Centre, Barts Health National Health Service Trust, London, United Kingdom
| | - Antonio Creta
- Barts Heart Centre, Barts Health National Health Service Trust, London, United Kingdom
| | - Nikhil Aluwhalia
- Barts Heart Centre, Barts Health National Health Service Trust, London, United Kingdom; William Harvey Research Institute, Queen Mary University of London, London, United Kingdom
| | - Shohreh Honarbakhsh
- Barts Heart Centre, Barts Health National Health Service Trust, London, United Kingdom; William Harvey Research Institute, Queen Mary University of London, London, United Kingdom
| | - Mehul Dhinoja
- Barts Heart Centre, Barts Health National Health Service Trust, London, United Kingdom
| | - Dhiraj Gupta
- Liverpool Heart and Chest Hospital, Liverpool, United Kingdom
| | - Malcolm Finlay
- Barts Heart Centre, Barts Health National Health Service Trust, London, United Kingdom; William Harvey Research Institute, Queen Mary University of London, London, United Kingdom.
| |
Collapse
|
9
|
Heeger CH, Kuck KH, Tilz RR. Very high-power short-duration catheter ablation for treatment of cardiac arrhythmias: Insights from the FAST and FURIOUS study series. J Cardiovasc Electrophysiol 2024; 35:547-556. [PMID: 37855621 DOI: 10.1111/jce.16113] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/17/2023] [Revised: 09/27/2023] [Accepted: 10/10/2023] [Indexed: 10/20/2023]
Abstract
The QDOT MICRO™ Catheter is a novel open-irrigated contact force-sensing radiofrequency ablation catheter. It offers very high-power short-duration (vHPSD) ablation with 90 W for 4 s to improve safety and efficacy of catheter ablation procedures. Although the QDOT MICRO™ Catheter was mainly designed for pulmonary vein isolation (PVI) its versatility to treat atrial fibrillation (AF) and other types of arrhythmias was recently evaluated by the FAST and FURIOUS study series and other studies and will be presented in this article. Available study and registry data as well as case reports concerning utilization of the QDOT MICRO™ Catheter for the treatment of cardiac arrhythmias including AF, focal and macroreentry atrial tachycardia, typical atrial flutter by cavotricuspid isthmus block, premature ventricular contractions, and accessory pathways were reviewed and summarized. In summary, the QDOT MICRO™ Catheter showed safety and efficacy for PVI and is able to treat also other types of arrhythmias as is was recently evaluated by case reports and the FAST and FURIOUS studies.
Collapse
Affiliation(s)
- Christian-H Heeger
- Department of Rhythmology, University Hospital Schleswig-Holstein, University Heart Center Lübeck, Lubeck, Germany
- German Center for Cardiovascular Research (DZHK), Partner Site Hamburg/Kiel/Lübeck, Lübeck, Germany
| | - Karl-Heinz Kuck
- Department of Rhythmology, University Hospital Schleswig-Holstein, University Heart Center Lübeck, Lubeck, Germany
- German Center for Cardiovascular Research (DZHK), Partner Site Hamburg/Kiel/Lübeck, Lübeck, Germany
| | - Roland R Tilz
- Department of Rhythmology, University Hospital Schleswig-Holstein, University Heart Center Lübeck, Lubeck, Germany
- German Center for Cardiovascular Research (DZHK), Partner Site Hamburg/Kiel/Lübeck, Lübeck, Germany
| |
Collapse
|
10
|
Liao Y, Tomaiko-Clark ED, Martinez J, Shinoda Y, Morris MF, Liu Z, Shatz DY, Katrapati P, Sahara N, Weiss JP, Zawaneh MS, Tung R, Bai R, Su W. Incidence of cryoballoon expansion dislodgement during pulmonary vein isolation-An underappreciated frequent cause of incomplete isolation. Pacing Clin Electrophysiol 2024; 47:347-352. [PMID: 38140909 DOI: 10.1111/pace.14910] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/22/2023] [Revised: 11/08/2023] [Accepted: 12/10/2023] [Indexed: 12/24/2023]
Abstract
BACKGROUND Cryoballoon ablation for atrial fibrillation (AF) requires adequate contact between the pulmonary vein (PV) antrum and cryoballoon. The surge of intraballoon pressure during the initial phase of ablation may change the balloon's shape and compliance, resulting in balloon dislodgement and loss of PV occlusion. Without continuous monitoring, this phenomenon is often undetected but can be associated with incomplete PV isolation (PVI). METHODS Primary cryoablation of AF was performed in 15 patients. PV occlusion status pre- and post-freezing were analyzed with intracardiac echocardiography (ICE) and dielectric imaging-based occlusion tool (DIOT) to calculate the incidence of expansion dislodgement of cryoballoon. RESULTS A total of 105 cryoablation applications were performed on 57 veins, including three common ostiums of left pulmonary veins. In the evaluation of PV occlusion, both modalities reported consistent results in 86.7% of the assessments. Despite complete PV occlusion before ablation, peri-balloon leak after initiation of freezing was detected by ICE in 5/22 (22.7%) applications and by DIOT in 8/25 (32%) applications. CONCLUSION Incidence of expansion dislodgement of the cryoballoon was detected in one-fourth to one-third of cryoablation applications depending on the imaging modality used, which was clinically frequent and significant.
Collapse
Affiliation(s)
- Yu Liao
- Division of Cardiology, Banner University Medical Center Phoenix, University of Arizona College of Medicine, Phoenix, Arizona, USA
- National Cheng Kung University Hospital, Tainan, Taiwan
| | | | - Jake Martinez
- Division of Cardiology, Banner University Medical Center Phoenix, University of Arizona College of Medicine, Phoenix, Arizona, USA
| | - Yasutoshi Shinoda
- Division of Cardiology, Banner University Medical Center Phoenix, University of Arizona College of Medicine, Phoenix, Arizona, USA
- Department of Cardiology, Faculty of Medicine, University of Tsukuba, Tsukuba, Japan
| | - Michael F Morris
- Division of Radiology, Banner University Medical Center Phoenix, University of Arizona College of Medicine, Phoenix, Arizona, USA
| | - Zhao Liu
- EPD Solutions, Best, Netherlands
| | - Dalise Yi Shatz
- University of Arizona College of Medicine, Phoenix, Arizona, USA
| | - Praneeth Katrapati
- Division of Cardiology, Banner University Medical Center Phoenix, University of Arizona College of Medicine, Phoenix, Arizona, USA
| | - Naohiko Sahara
- Division of Cardiology, Banner University Medical Center Phoenix, University of Arizona College of Medicine, Phoenix, Arizona, USA
- Toho University Ohashi Medical Center, Tokyo, Japan
| | - J Peter Weiss
- Division of Cardiology, Banner University Medical Center Phoenix, University of Arizona College of Medicine, Phoenix, Arizona, USA
- University of Arizona College of Medicine, Phoenix, Arizona, USA
| | - Michael S Zawaneh
- Division of Cardiology, Banner University Medical Center Phoenix, University of Arizona College of Medicine, Phoenix, Arizona, USA
- University of Arizona College of Medicine, Phoenix, Arizona, USA
| | - Roderick Tung
- Division of Cardiology, Banner University Medical Center Phoenix, University of Arizona College of Medicine, Phoenix, Arizona, USA
- University of Arizona College of Medicine, Phoenix, Arizona, USA
| | - Rong Bai
- Division of Cardiology, Banner University Medical Center Phoenix, University of Arizona College of Medicine, Phoenix, Arizona, USA
- University of Arizona College of Medicine, Phoenix, Arizona, USA
| | - Wilber Su
- Division of Cardiology, Banner University Medical Center Phoenix, University of Arizona College of Medicine, Phoenix, Arizona, USA
- University of Arizona College of Medicine, Phoenix, Arizona, USA
| |
Collapse
|
11
|
Knappe V, Lahrmann C, Funken M, Zietzer A, Gestrich C, Nickenig G, Schrickel JW, Beiert T. Comparison of Arctic Front Advance Pro and POLARx cryoballoons for ablation therapy of atrial fibrillation: an intraprocedural analysis. Clin Res Cardiol 2024:10.1007/s00392-024-02398-2. [PMID: 38358420 DOI: 10.1007/s00392-024-02398-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/22/2023] [Accepted: 02/05/2024] [Indexed: 02/16/2024]
Abstract
INTRODUCTION Cryoballoon (CB) ablation has become a popular method for pulmonary vein isolation (PVI) in atrial fibrillation (AF) treatment. This study aimed to compare the intraprocedural ablation characteristics of two cryoballoons, Arctic Front Advance Pro™ (AFA-Pro, Medtronic) and POLARx™ (Boston Scientific). METHODS AND RESULTS In this retrospective single-center study, 230 symptomatic paroxysmal or persistent AF patients underwent CB ablation with either AFA-Pro or POLARx. Propensity-score matching resulted in two cohorts of 114 patients each. Baseline and procedural characteristics were comparable between both CBs. POLARx achieved lower minimal temperatures (e.g., left superior pulmonary vein, LSPV: AFA-Pro - 49.0 °C vs. POLARx - 59.5 °C) and lower temperatures at time-to-isolation (TTI). Additionally, POLARx reached lower temperatures faster, as evidenced by lower temperatures after 40 and 60 s, and a larger mean temperature change between 20 and 40 s. POLARx also had a greater area under the curve below 0 °C and a longer thawing phase. Both CBs achieved comparable high rates of final PV-isolation. TTI, minimal esophagus temperature, and first-pass isolation rates were similar between groups. Periprocedural complications, including phrenic nerve injuries, were comparable. Troponin levels in the left atrium were elevated with both systems. Values and change in troponin were numerically higher in the POLARx group (delta troponin: AFA-Pro 36.3 (26.4, 125.4) ng/L vs. POLARx 104.9 (49.5, 122.2) ng/L), p = 0.077). CONCLUSION AFA-Pro and POLARx are both highly effective and safe CB systems for PVI. POLARx exhibited significant faster and lower freezing characteristics, and numerically higher troponin levels might indicate greater myocardial injury. However, these differences did not translate into improved performance, procedural efficiency, or safety.
Collapse
Affiliation(s)
- Vincent Knappe
- Heart Center Bonn, Department of Internal Medicine II, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany.
| | - Caroline Lahrmann
- Heart Center Bonn, Department of Internal Medicine II, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
| | - Maximilian Funken
- Heart Center Bonn, Department of Internal Medicine II, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
| | - Andreas Zietzer
- Heart Center Bonn, Department of Internal Medicine II, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
| | - Christopher Gestrich
- Heart Center Bonn, Department of Internal Medicine II, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
| | - Georg Nickenig
- Heart Center Bonn, Department of Internal Medicine II, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
| | - Jan W Schrickel
- Heart Center Bonn, Department of Internal Medicine II, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
| | - Thomas Beiert
- Heart Center Bonn, Department of Internal Medicine II, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany
| |
Collapse
|
12
|
Heeger CH, Subin B, Eitel C, Ștefan Popescu S, Phan HL, Mamaev R, Bartoli L, Große N, Reincke S, Traub A, Lopez D, Kirstein B, Hatahet S, Kuck KH, Vogler J, Tilz RR. Pulmonary vein isolation durability after very high-power short-duration ablation utilizing a very-close protocol - The FAST AND FURIOUS redo study. INTERNATIONAL JOURNAL OF CARDIOLOGY. HEART & VASCULATURE 2024; 50:101325. [PMID: 38419611 PMCID: PMC10899720 DOI: 10.1016/j.ijcha.2023.101325] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/13/2023] [Revised: 12/02/2023] [Accepted: 12/11/2023] [Indexed: 03/02/2024]
Abstract
Background Very high-power short-duration (vHP-SD) radiofrequency (RF) ablation of atrial fibrillation (AF) treatment by pulmonary vein isolation (PVI) aims for safer, more effective and faster procedures. Although acute efficacy and safety for PVI was recently shown data on chronic PVI durability is limited. Here chronic PVI durability was evaluated during repeat electrophysiological procedures in patients after initial vHP-SD and conventional RF based PVI. Methods A total of 25 consecutive patients with repeat left atrial procedures after initial vHP-SD based PVI were included in this study. Twenty-five patients with previous conventional RF based PVI and repeat left atrial procedures served as control (control group). Results For index procedures the median RF time was 328 (277, 392) seconds (vHP-SD) and 1470 (1310, 1742) seconds (control); p < 0.001, the median procedure time was 55 (53, 68) minutes (vHP-SD) and 110 (94, 119) (control); p < 0.001). First pass isolation rate was 84 % (vHP-SD) and 88 % (control, p = 0.888). No differences for severe adverse events (vHP-SD: 1/25, 4 % vs. control: 0/25, 0 %; p = 0.676 were detected.Chronic durability of all PVs was assessed in vHP-SD: 16/25 (64 %) and control: 8/25 (32 %) patients (p = 0.023) and vHP-SD: 81 % and control: 62 % of PVs were found to be isolated (p = 0.003). For right PVs vHP-SD: 84 % vs. control: 60 % of PVs (p < 0.001) and for left PVs vHP-SD: 78 % vs. control: 64 % (p = 0.123) were found to be isolated. Conclusions PVI solely utilizing vHP-SD via a very close-protocol provides fast, safe and effective acute PVI. High rates of chronically isolated pulmonary veins have been detected.
Collapse
Affiliation(s)
- Christian-H Heeger
- University Heart Center Lübeck, Department of Rhythmology, University Hospital Schleswig-Holstein, Germany
- German Center for Cardiovascular Research (DZHK), Partner Site Hamburg/Kiel/Lübeck, Lübeck, Germany
| | - Behnam Subin
- University Heart Center Lübeck, Department of Rhythmology, University Hospital Schleswig-Holstein, Germany
| | - Charlotte Eitel
- University Heart Center Lübeck, Department of Rhythmology, University Hospital Schleswig-Holstein, Germany
| | - Sorin Ștefan Popescu
- University Heart Center Lübeck, Department of Rhythmology, University Hospital Schleswig-Holstein, Germany
| | - Huong-Lan Phan
- University Heart Center Lübeck, Department of Rhythmology, University Hospital Schleswig-Holstein, Germany
| | - Roman Mamaev
- University Heart Center Lübeck, Department of Rhythmology, University Hospital Schleswig-Holstein, Germany
| | - Lorenzo Bartoli
- University Heart Center Lübeck, Department of Rhythmology, University Hospital Schleswig-Holstein, Germany
| | - Niels Große
- University Heart Center Lübeck, Department of Rhythmology, University Hospital Schleswig-Holstein, Germany
| | - Samuel Reincke
- University Heart Center Lübeck, Department of Rhythmology, University Hospital Schleswig-Holstein, Germany
| | - Anna Traub
- University Heart Center Lübeck, Department of Rhythmology, University Hospital Schleswig-Holstein, Germany
| | - Delgado Lopez
- University Heart Center Lübeck, Department of Rhythmology, University Hospital Schleswig-Holstein, Germany
| | - Bettina Kirstein
- University Heart Center Lübeck, Department of Rhythmology, University Hospital Schleswig-Holstein, Germany
| | - Sascha Hatahet
- University Heart Center Lübeck, Department of Rhythmology, University Hospital Schleswig-Holstein, Germany
| | - Karl-Heinz Kuck
- University Heart Center Lübeck, Department of Rhythmology, University Hospital Schleswig-Holstein, Germany
| | - Julia Vogler
- University Heart Center Lübeck, Department of Rhythmology, University Hospital Schleswig-Holstein, Germany
| | - Roland R Tilz
- University Heart Center Lübeck, Department of Rhythmology, University Hospital Schleswig-Holstein, Germany
- German Center for Cardiovascular Research (DZHK), Partner Site Hamburg/Kiel/Lübeck, Lübeck, Germany
| |
Collapse
|
13
|
Fukunaga H, Sekiguchi Y, Sawaguchi J, Hayashi Y, Asano S, Mabuchi K, Inoue K, Tanizaki K, Umemura J, Isobe M, Nitta J. Initial clinical experience with the novel POLARx FIT cryoballoon system for pulmonary vein isolation in patients with atrial fibrillation. IJC HEART & VASCULATURE 2024; 50:101326. [PMID: 38192687 PMCID: PMC10772259 DOI: 10.1016/j.ijcha.2023.101326] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2023] [Revised: 12/05/2023] [Accepted: 12/12/2023] [Indexed: 01/10/2024]
Abstract
Background The POLARx FIT system (Boston Scientific, MA, USA) is a novel cryoballoon (CB) ablation technology in which the balloon diameter can be expanded from 28 to 31 mm. The aim of this study was to compare the benefits and safety of the new POLARx FIT system to those of the existing POLARx system currently in use for pulmonary vein (PV) isolation (PVI) in patients with atrial fibrillation. Methods The first 70 consecutive patients who underwent CB-based PVI with the POLARx FIT system were retrospectively compared with 200 consecutive patients treated with the POLARx system at Sakakibara Heart Institute from October 2021 to May 2023. Results The POLARx FIT system yielded a higher mean ± standard deviation nadir temperature in the right inferior PV (-59.2 ± 5.29 °C vs. - 62.0 ± 5.08 °C, p = 0.006), but this required a balloon size reduction to 28 mm in 30 % of cases. No significant differences were detected in the time to isolation and thaw time of any PV between the two groups. After the CB-based PVI procedure, no residual PV carina potentials were observed with the POLARx FIT system, whereas 4/20 were with the POLARx system (p = 0.04). Conclusions The POLARx FIT system had comparable effectiveness and safety to the basic POLARx system. This technology may improve the ablation area, including the PV carina. However, the 31-mm balloon alone was not sufficient to isolate certain PVs.
Collapse
|
14
|
Ikenouchi T, Miyazaki S, Nitta J, Sekiguchi Y, Kobori A, Nakamura K, Inamura Y, Murakami M, Sagawa Y, Sasaki Y, Inaba O, Yamauchi Y, Naito S, Hirakawa A, Sasano T. Characteristics of two different cryoballoon systems for treatment of paroxysmal atrial fibrillation: study protocol for a multicenter randomized controlled trial (CONTRAST-CRYO Trial). J Interv Card Electrophysiol 2024; 67:5-12. [PMID: 38087145 DOI: 10.1007/s10840-023-01718-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/16/2023] [Accepted: 12/03/2023] [Indexed: 01/06/2024]
Abstract
BACKGROUND Single-shot pulmonary vein isolation (PVI) utilizing cryothermal energy is an effective and safe treatment for atrial fibrillation (AF) patients. A novel cryoballoon system, POLARx™, has been recently introduced. The aim of this study was to compare the efficacy, safety, and biophysical parameters of PVI between the novel cryoballoon system, POLARx™, and the standard cryoballoon system, Arctic Front Advance Pro™ (AFA-Pro), in patients with paroxysmal AF. METHODS The CONTRAST-CRYO trial is a prospective, multicenter, open-label, randomized controlled study performed at seven large cardiac centers. This study was approved by the central ethics committee or the local ethics committee of each participating hospital and has been registered at UMIN Clinical Trials Registry (UMIN000049948). The trial will assign 200 patients with paroxysmal AF undergoing PVI to POLARx™ and AFA-Pro in a 1:1 randomization. The primary endpoint is the one-shot acute success rate of the right inferior pulmonary vein. Second endpoints include freedom from documented atrial fibrillation, atrial flutter, or atrial tachycardia without antiarrhythmic drugs at 12 months after the procedure, freedom from re-do procedures, the incidence of procedure-related adverse events, freezing duration, and the biophysical parameters during applications for each PV, total procedure and fluoroscopy time, and PVI durability during re-do procedures. CONCLUSION The CONTRAST-CRYO trial is a prospective, multicenter, randomized study designed to elucidate the difference in the efficacy, safety, and biophysical parameters between POLARx™ and AFA-Pro in paroxysmal AF patients undergoing PVI. The findings from this trial may provide a valuable indication for selecting the optimal cryoballoon system. CLINICAL TRIAL REGISTRATION UMIN000049948.
Collapse
Affiliation(s)
- Takashi Ikenouchi
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University Hospital, Yushima 1-5-45, Bunkyo-ku, Tokyo, 113-8510, Japan
| | - Shinsuke Miyazaki
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University Hospital, Yushima 1-5-45, Bunkyo-ku, Tokyo, 113-8510, Japan.
| | - Junichi Nitta
- Department of Cardiology, Sakakibara Heart Institute, Fuchu-shi, Tokyo, Japan
| | - Yukio Sekiguchi
- Department of Cardiology, Sakakibara Heart Institute, Fuchu-shi, Tokyo, Japan
| | - Atsushi Kobori
- Department of Cardiology, Kobe City Medical Center General Hospital, Kobe-shi, Hyogo, Japan
| | - Kohki Nakamura
- Devision of Cardiology, Gunma Prefectural Cardiovascular Center, Maebashi-shi, Gunma, Japan
| | - Yukihiro Inamura
- Department of Cardiology, Japanese Red Cross Saitama Hospital, Saitama-shi, Japan
| | - Masato Murakami
- Department of Cardiology, Shonankamakura General Hospital, Kamakura-shi, Kanagawa, Japan
| | - Yuichiro Sagawa
- Department of Cardiology, Japanese Red Cross Yokohama City Bay Hospital, Yokohama-shi, Kanagawa, Japan
| | - Yasuhiro Sasaki
- Department of Cardiology, Kobe City Medical Center General Hospital, Kobe-shi, Hyogo, Japan
| | - Osamu Inaba
- Department of Cardiology, Japanese Red Cross Saitama Hospital, Saitama-shi, Japan
| | - Yasuteru Yamauchi
- Department of Cardiology, Japanese Red Cross Yokohama City Bay Hospital, Yokohama-shi, Kanagawa, Japan
| | - Shigeto Naito
- Devision of Cardiology, Gunma Prefectural Cardiovascular Center, Maebashi-shi, Gunma, Japan
| | - Akihiro Hirakawa
- Department of Clinical Biostatistics, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Bunkyo-ku, Tokyo, Japan
| | - Tetsuo Sasano
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University Hospital, Yushima 1-5-45, Bunkyo-ku, Tokyo, 113-8510, Japan
| |
Collapse
|
15
|
Funasako M, Petrů J, Hála P, Janotka M, Škoda J, Chovanec M, Šedivá L, Reddy VY, Neužil P. Acute and long-term results with the 3 rd generation visually guided laser balloon ablation system for pv isolation. J Interv Card Electrophysiol 2024; 67:53-60. [PMID: 36805921 PMCID: PMC10770210 DOI: 10.1007/s10840-023-01499-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/14/2022] [Accepted: 01/30/2023] [Indexed: 02/23/2023]
Abstract
BACKGROUND Visually guided laser balloon ablation is known as an effective pulmonary vein (PV) isolation device. The third-generation laser balloon ablation system (X3) equipped with compliant balloon and an automated motor-driven laser output mechanism, namely RAPID mode, has been clinically proven for PV isolation. METHODS PV isolation with X3 was performed in all the patients with paroxysmal and early-stage persistent atrial fibrillation (AF). Acute data for PV isolation and clinical outcomes including supraventricular tachyarrhythmia (SVT: AF, atrial flutter, or atrial tachycardia)-free survival rate beyond 1 year were analyzed. RESULTS A total of 110 patients (62 ± 13 years old, 80% of paroxysmal AF) were treated with X3. RAPID mode with was utilized to achieve PV isolation in all cases. In combination with RAPID mode and spot mode laser ablation, 91.1% (380/417) of veins were isolated on the first circumferential lesion set and did not require touch-up ablation and during the index procedure 100% of attempted veins were isolated. The mean procedure time was 77.0 ± 22.7 min and LA dwell time was 61.9 ± 22.0 min. Total duration of laser application was 5.1 ± 2.3 min per vein. At 1 year, SVT-free survival rate was 93.7% in paroxysmal AF patients, and 81.1% in persistent AF patients. CONCLUSIONS A novel continuous automatic laser balloon ablation system was proved to be safe and effective for both paroxysmal and persistent AF patients. The clinical result demonstrated that PV isolation with X3 could achieve a high SVT-free survival rate.
Collapse
Affiliation(s)
- Moritoshi Funasako
- Cardiology Department, Na Homolce Hospital, Roentgenova 2, Prague, 15030, Czech Republic.
| | - Jan Petrů
- Cardiology Department, Na Homolce Hospital, Roentgenova 2, Prague, 15030, Czech Republic
| | - Pavel Hála
- Cardiology Department, Na Homolce Hospital, Roentgenova 2, Prague, 15030, Czech Republic
| | - Marek Janotka
- Cardiology Department, Na Homolce Hospital, Roentgenova 2, Prague, 15030, Czech Republic
| | - Jan Škoda
- Cardiology Department, Na Homolce Hospital, Roentgenova 2, Prague, 15030, Czech Republic
| | - Milan Chovanec
- Cardiology Department, Na Homolce Hospital, Roentgenova 2, Prague, 15030, Czech Republic
| | - Lucie Šedivá
- Cardiology Department, Na Homolce Hospital, Roentgenova 2, Prague, 15030, Czech Republic
| | - Vivek Y Reddy
- Cardiology Department, Na Homolce Hospital, Roentgenova 2, Prague, 15030, Czech Republic
- The Helmsley Electrophysiology Center, Mount Sinai School of Medicine, New York, NY, USA
| | - Petr Neužil
- Cardiology Department, Na Homolce Hospital, Roentgenova 2, Prague, 15030, Czech Republic
| |
Collapse
|
16
|
Isonaga Y, Miyazaki S, Nitta J, Shirai Y, Inamura Y, Sagawa Y, Yamauchi Y, Sasaki T, Inaba O, Sasano T. Acute procedural efficacy and safety of a novel expandable diameter cryoballoon in atrial fibrillation ablation: Early results from a multicenter ablation registry. J Cardiovasc Electrophysiol 2024; 35:198-205. [PMID: 38037864 DOI: 10.1111/jce.16135] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/25/2023] [Revised: 10/31/2023] [Accepted: 11/06/2023] [Indexed: 12/02/2023]
Abstract
INTRODUCTION The major limitation of the current cryoballoon (CB) system is a fixed 28 mm balloon-size. We sought to analyze real-world early experience with novel-sized adjustable CB. METHODS This multicenter observational study included 140 consecutive atrial fibrillation patients (71 years, 94 men, 86 paroxysmal) who underwent pulmonary vein (PV) isolation using expandable diameter CB capable of ablation at 28 or 31 mm. RESULTS Out of 544 targeted PVs, 526 (96.7%) were successfully isolated by a size-adjustable CB with a 770 [690-870] second median application dose, while the remaining 18 required touch-up ablation. Among them, 326 (62.0%) PVs were isolated by a 31 mm balloon, and the rate was significantly higher for upper than lower PVs (73.0% vs. 45.7%, p < .0001) and highest for right superior (78.5%) and lowest for right inferior (39.9%) PVs. The biophysical parameters and time to isolation were comparable between the 28 and 31 mm balloons, however, the real-time PV potential monitoring capability was significantly higher for 31 mm than 28 mm balloons for the left superior PV. The esophageal temperature reached 15°C during left inferior PV ablation significantly more often with 31 mm than 28 mm balloons (43.1% vs. 18.2%, p = .008). Right phrenic nerve injury (PNI) occurred in 9 (6.4%) patients during applications (6 right superior, 2 right inferior PVs), and most occurred with a 31 mm balloon. CONCLUSIONS Our real-world early data demonstrated high acute efficacy and safety of the novel-sized adjustable CB. The biophysical parameters were similar between the 28 and 31 mm balloons. No marked decrease in the incidence of PNI was observed even with 31 mm balloons.
Collapse
Affiliation(s)
- Yuhei Isonaga
- Department of Cardiology, Japanese Red Cross Saitama Hospital, Saitama, Japan
| | - Shinsuke Miyazaki
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University, Tokyo, Japan
| | - Junichi Nitta
- Department of Cardiology, Sakakibara Heart Institute, Tokyo, Japan
| | - Yasuhiro Shirai
- Department of Cardiology, Disaster Medical Center, Tokyo, Japan
| | - Yukihiro Inamura
- Department of Cardiology, Japanese Red Cross Saitama Hospital, Saitama, Japan
| | - Yuichiro Sagawa
- Department of Cardiology, Japanese Red Cross Yokohama City Bay Hospital, Yokohama, Kanagawa, Japan
| | - Yasuteru Yamauchi
- Department of Cardiology, Japanese Red Cross Yokohama City Bay Hospital, Yokohama, Kanagawa, Japan
| | - Takeshi Sasaki
- Department of Cardiology, Disaster Medical Center, Tokyo, Japan
| | - Osamu Inaba
- Department of Cardiology, Japanese Red Cross Saitama Hospital, Saitama, Japan
| | - Tetsuo Sasano
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University, Tokyo, Japan
| |
Collapse
|
17
|
Badertscher P, Weidlich S, Knecht S, Stauffer N, Krisai P, Voellmin G, Osswald S, Sticherling C, Kühne M. Efficacy and safety of pulmonary vein isolation with pulsed field ablation vs. novel cryoballoon ablation system for atrial fibrillation. Europace 2023; 25:euad329. [PMID: 38036293 PMCID: PMC10751845 DOI: 10.1093/europace/euad329] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2023] [Accepted: 10/30/2023] [Indexed: 12/02/2023] Open
Abstract
AIMS Pulsed-field ablation (PFA) has emerged as a novel treatment technology for patients with atrial fibrillation (AF). Cryoballoon (CB) is the most frequently used single shot technology. A direct comparison to a novel CB system is lacking. We aimed to compare pulmonary vein isolation (PVI) using PFA vs. a novel CB system regarding efficiency, safety, myocardial injury, and outcomes. METHODS AND RESULTS One hundred and eighty-one consecutive patients underwent PVI and were included (age 64 ± 9.7 years, ejection fraction 0.58 ± 0.09, left atrial size 40 ± 6.4 mm, paroxysmal AF 64%). 106 patients (59%) underwent PFA (FARAPULSE, Boston Scientific) and 75 patients (41%) underwent CB ablation (PolarX, Boston Scientific). The median procedure time, left atrial dwell time and fluoroscopic time were similar between the PFA and the CB group with 55 [interquartile range (IQR) 43-64] min vs. 58 (IQR 48-69) min (P < 0.087), 38 (30-49) min vs. 37 (31-48) min, (P = 0.871), and 11 (IQR 9.3-14) min vs. 11 (IQR 8.7-16) min, (P < 0.81), respectively. Three procedural complications were observed in the PFA group (two tamponades, one temporary ST elevation) and three complications in the CB group (3× reversible phrenic nerve palsies). During the median follow-up of 404 days (IQR 208-560), AF recurrence was similar in the PFA group and the CB group with 24 vs. 30%, P = 0.406. CONCLUSION Procedural characteristics were very similar between PFA and CB in regard to procedure duration fluoroscopy time and complications. Atrial fibrillation free survival did not differ between the PFA and CB groups.
Collapse
Affiliation(s)
- Patrick Badertscher
- Department of Cardiology, University Hospital Basel, Petersgraben 4, 4031 Basel, Switzerland
- Cardiovascular Research Institute Basel, University Hospital Basel, Spitalstrasse 2, 4056 Basel, Switzerland
| | - Simon Weidlich
- Department of Cardiology, University Hospital Basel, Petersgraben 4, 4031 Basel, Switzerland
- Cardiovascular Research Institute Basel, University Hospital Basel, Spitalstrasse 2, 4056 Basel, Switzerland
| | - Sven Knecht
- Department of Cardiology, University Hospital Basel, Petersgraben 4, 4031 Basel, Switzerland
- Cardiovascular Research Institute Basel, University Hospital Basel, Spitalstrasse 2, 4056 Basel, Switzerland
| | - Niklas Stauffer
- Department of Cardiology, University Hospital Basel, Petersgraben 4, 4031 Basel, Switzerland
- Cardiovascular Research Institute Basel, University Hospital Basel, Spitalstrasse 2, 4056 Basel, Switzerland
| | - Philipp Krisai
- Department of Cardiology, University Hospital Basel, Petersgraben 4, 4031 Basel, Switzerland
- Cardiovascular Research Institute Basel, University Hospital Basel, Spitalstrasse 2, 4056 Basel, Switzerland
| | - Gian Voellmin
- Department of Cardiology, University Hospital Basel, Petersgraben 4, 4031 Basel, Switzerland
- Cardiovascular Research Institute Basel, University Hospital Basel, Spitalstrasse 2, 4056 Basel, Switzerland
| | - Stefan Osswald
- Department of Cardiology, University Hospital Basel, Petersgraben 4, 4031 Basel, Switzerland
- Cardiovascular Research Institute Basel, University Hospital Basel, Spitalstrasse 2, 4056 Basel, Switzerland
| | - Christian Sticherling
- Department of Cardiology, University Hospital Basel, Petersgraben 4, 4031 Basel, Switzerland
- Cardiovascular Research Institute Basel, University Hospital Basel, Spitalstrasse 2, 4056 Basel, Switzerland
| | - Michael Kühne
- Department of Cardiology, University Hospital Basel, Petersgraben 4, 4031 Basel, Switzerland
- Cardiovascular Research Institute Basel, University Hospital Basel, Spitalstrasse 2, 4056 Basel, Switzerland
| |
Collapse
|
18
|
Zylla MM, Starrach L, Rahm AK, Thomas D, Frey N, Lugenbiel P. Implementation of the multielectrode radiofrequency-balloon in real-world clinical practice-operator learning curve and procedural outcome at a high-volume center. Front Cardiovasc Med 2023; 10:1208250. [PMID: 38034374 PMCID: PMC10682364 DOI: 10.3389/fcvm.2023.1208250] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2023] [Accepted: 07/03/2023] [Indexed: 12/02/2023] Open
Abstract
Background The novel multielectrode radiofrequency (RF) balloon catheter (HELIOSTAR™, Biosense Webster) is a new technology for pulmonary vein isolation (PVI) in atrial fibrillation (AF), combining RF-ablation and 3D-mapping visualization with the concept of a "single-shot"-ablation device. This study evaluates the operator learning curve und procedural outcome during implementation of the multielectrode RF-balloon at a high-volume center. Methods The first 40 patients undergoing PVI by multielectrode RF-balloon catheter at Heidelberg University Hospital were included in this prospective study. Procedural outcome was analyzed over the course of increasing experience with the device. Results 157/157 pulmonary veins (PVs) were successfully isolated with the RF-balloon catheter, in 73.2% by a single RF-application. Median time to isolation (TTI) was 11.0 s (Q1 = 8.0 s; Q3 = 13.8 s). Median procedure time was 62.5 min (Q1 = 50.0 min; Q3 = 70.5 min). LA-dwell time was 28.5 min (Q1 = 23.3 min; Q3 = 36.5 min). Median fluoroscopy duration was 11.6 min (Q1 = 10.1 min; Q3 = 13.7 min). No serious procedure-related complications were observed, apart from one case of unclear, post-procedural acute-on-chronic kidney injury. With increasing operator experience, an additional reduction in procedure duration was observed. Conclusion Rapid implementation of a "single shot"-ablation device combining RF-ablation and 3D-mapping can be achieved with high acute procedural efficacy and safety at a high-volume center. Previous experience with "single-shot" ablation devices may be advantageous for time-efficient introduction of the novel RF-balloon catheter into clinical practice. Clinical Trial Registration ClinicalTrials.gov; Identifier NCT0560361.
Collapse
Affiliation(s)
- Maura M. Zylla
- Department of Cardiology, Medical University Hospital, Heidelberg, Germany
- HCR (Heidelberg Center for Heart Rhythm Disorders), Medical University Hospital, Heidelberg, Germany
- DZHK (German Center for Cardiovascular Research), Partner Site Heidelberg/Mannheim, Heidelberg, Germany
| | - Lydia Starrach
- Department of Cardiology, Medical University Hospital, Heidelberg, Germany
- HCR (Heidelberg Center for Heart Rhythm Disorders), Medical University Hospital, Heidelberg, Germany
- DZHK (German Center for Cardiovascular Research), Partner Site Heidelberg/Mannheim, Heidelberg, Germany
| | - Ann-Kathrin Rahm
- Department of Cardiology, Medical University Hospital, Heidelberg, Germany
- HCR (Heidelberg Center for Heart Rhythm Disorders), Medical University Hospital, Heidelberg, Germany
- DZHK (German Center for Cardiovascular Research), Partner Site Heidelberg/Mannheim, Heidelberg, Germany
| | - Dierk Thomas
- Department of Cardiology, Medical University Hospital, Heidelberg, Germany
- HCR (Heidelberg Center for Heart Rhythm Disorders), Medical University Hospital, Heidelberg, Germany
- DZHK (German Center for Cardiovascular Research), Partner Site Heidelberg/Mannheim, Heidelberg, Germany
| | - Norbert Frey
- Department of Cardiology, Medical University Hospital, Heidelberg, Germany
- HCR (Heidelberg Center for Heart Rhythm Disorders), Medical University Hospital, Heidelberg, Germany
- DZHK (German Center for Cardiovascular Research), Partner Site Heidelberg/Mannheim, Heidelberg, Germany
| | - Patrick Lugenbiel
- Department of Cardiology, Medical University Hospital, Heidelberg, Germany
- HCR (Heidelberg Center for Heart Rhythm Disorders), Medical University Hospital, Heidelberg, Germany
- DZHK (German Center for Cardiovascular Research), Partner Site Heidelberg/Mannheim, Heidelberg, Germany
| |
Collapse
|
19
|
Honarbakhsh S, Martin CA, Mesquita J, Herlekar R, Till R, Srinivasan NT, Duncan E, Leong F, Dulai R, Veasey R, Panikker S, Paisey J, Ramgopal B, Das M, Ahmed W, Sahu J, Earley MJ, Finlay MC, Schilling RJ, Hunter RJ. Atrial fibrillation cryoablation is an effective day case treatment: the UK PolarX vs. Arctic Front Advance experience. Europace 2023; 25:euad286. [PMID: 37738643 PMCID: PMC10629714 DOI: 10.1093/europace/euad286] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2023] [Accepted: 07/28/2023] [Indexed: 09/24/2023] Open
Abstract
AIMS Pulmonary vein isolation (PVI) is the cornerstone of catheter ablation for atrial fibrillation (AF). There are limited data on the PolarX Cryoballoon. The study aimed to establish the safety, efficacy, and feasibility of same day discharge for Cryoballoon PVI. METHODS AND RESULTS Multi-centre study across 12 centres. Procedural metrics, safety profile, and procedural efficacy of the PolarX Cryoballoon with the Arctic Front Advance (AFA) Cryoballoon were compared in a cohort large enough to provide definitive comparative data. A total of 1688 patients underwent PVI with cryoablation (50% PolarX and 50% AFA). Successful PVI was achieved with 1677 (99.3%) patients with 97.2% (n = 1641) performed as day case procedures with a complication rate of <1%. Safety, procedural metrics, and efficacy of the PolarX Cryoballoon were comparable with the AFA cohort. The PolarX Cryoballoon demonstrated a nadir temperature of -54.6 ± 7.6°C, temperature at 30 s of -38.6 ± 7.2°C, time to -40°C of 34.1 ± 13.7 s, and time to isolation of 49.8 ± 33.2 s. Independent predictors for achieving PVI included time to reach -40°C [odds ratio (OR) 1.34; P < 0.001] and nadir temperature (OR 1.24; P < 0.001) with an optimal cut-off of ≤34 s [area under the curve (AUC) 0.73; P < 0.001] and nadir temperature of ≤-54.0°C (AUC 0.71; P < 0.001), respectively. CONCLUSIONS This large-scale UK multi-centre study has shown that Cryoballoon PVI is a safe, effective day case procedure. PVI using the PolarX Cryoballoon was similarly safe and effective as the AFA Cryoballoon. The cryoablation metrics achieved with the PolarX Cryoballoon were different to that reported with the AFA Cryoballoon. Modified cryoablation targets are required when utilizing the PolarX Cryoballoon.
Collapse
Affiliation(s)
- Shohreh Honarbakhsh
- The Barts Heart Centre, St Bartholomew’s Hospital, Barts Health NHS trust, W Smithfield, EC1A 7BE London, UK
- William Harvey Research Institute, Queen Mary University of London, London, UK
| | - Claire A Martin
- Department of Electrophysiology, Royal Papworth Hospital, Cambridge, UK
- Department of Medicine, University of Cambridge, Cambridge, UK
| | - Joao Mesquita
- Department of Electrophysiology, Royal Papworth Hospital, Cambridge, UK
| | - Rahul Herlekar
- Department of Electrophysiology, Royal Papworth Hospital, Cambridge, UK
| | - Richard Till
- Department of Electrophysiology, Norfolk and Norwich University Hospitals NHS Foundation Trust, Norwich, UK
| | - Neil T Srinivasan
- Department of Electrophysiology, Basildon and Thurrock University Hospital NHS Foundation Trust, Essex, UK
| | - Edward Duncan
- Department of Electrophysiology, The University Hospitals Bristol and Weston NHS Foundation trust, Bristol, UK
| | - Fong Leong
- Department of Electrophysiology, Cardiff and Vale University Health Board, Cardiff, UK
| | - Rajdip Dulai
- Department of Electrophysiology, Eastbourne District General Hospital, East Sussex Healthcare NHS trust, Eastbourne, UK
| | - Rick Veasey
- Department of Electrophysiology, Eastbourne District General Hospital, East Sussex Healthcare NHS trust, Eastbourne, UK
| | - Sandeep Panikker
- Department of Electrophysiology, University Hospital Coventry and Warwickshire, Coventry, UK
| | - John Paisey
- Department of Electrophysiology, University Hospital Southampton NHS Foundation Trust, Southampton, UK
| | - Balasubramanian Ramgopal
- Department of Electrophysiology, University Hospital Southampton NHS Foundation Trust, Southampton, UK
| | - Moloy Das
- Department of Electrophysiology, Freeman Hospital, The Newcastle Upon Tyne Hospitals NHS Foundation Trust, Newcastle, UK
| | - Wissam Ahmed
- Department of Electrophysiology, Freeman Hospital, The Newcastle Upon Tyne Hospitals NHS Foundation Trust, Newcastle, UK
| | - Jonathan Sahu
- Department of Electrophysiology, Sheffield Teaching Hospitals NHS Foundation Trust, Sheffield, UK
| | - Mark J Earley
- The Barts Heart Centre, St Bartholomew’s Hospital, Barts Health NHS trust, W Smithfield, EC1A 7BE London, UK
- Department of Electrophysiology, OneWellbeck, 1 Wellbeck Street, W1G 0AR London, UK
| | - Malcolm C Finlay
- The Barts Heart Centre, St Bartholomew’s Hospital, Barts Health NHS trust, W Smithfield, EC1A 7BE London, UK
| | - Richard J Schilling
- The Barts Heart Centre, St Bartholomew’s Hospital, Barts Health NHS trust, W Smithfield, EC1A 7BE London, UK
- Department of Electrophysiology, OneWellbeck, 1 Wellbeck Street, W1G 0AR London, UK
| | - Ross J Hunter
- The Barts Heart Centre, St Bartholomew’s Hospital, Barts Health NHS trust, W Smithfield, EC1A 7BE London, UK
- Department of Electrophysiology, OneWellbeck, 1 Wellbeck Street, W1G 0AR London, UK
| |
Collapse
|
20
|
Maurhofer J, Kueffer T, Knecht S, Madaffari A, Badertscher P, Seiler J, Krisai P, Jufer C, Asatryan B, Heg D, Servatius H, Tanner H, Kühne M, Roten L, Sticherling C, Reichlin T. Comparison of the PolarX and the Arctic Front cryoballoon for pulmonary vein isolation in patients with symptomatic paroxysmal atrial fibrillation (COMPARE CRYO) - Study protocol for a randomized controlled trial. Contemp Clin Trials 2023; 134:107341. [PMID: 37722483 DOI: 10.1016/j.cct.2023.107341] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2023] [Revised: 08/24/2023] [Accepted: 09/15/2023] [Indexed: 09/20/2023]
Abstract
INTRODUCTION Single-shot devices are increasingly used for pulmonary vein isolation (PVI) in atrial fibrillation (AF). The Arctic Front cryoballoon (Medtronic) is the most frequently used single-shot technology. A recently developed novel cryoballoon has been introduced (PolarX, Boston Scientific) with the aim to address limitations of the Arctic Front system. METHODS COMPARE CRYO is a multicentre, randomized, controlled trial with blinded endpoint adjudication by an independent clinical events committee. A total of 200 patients with paroxysmal AF undergoing their first PVI are randomized 1:1 between PolarX cryoballoon ablation and Arctic Front cryoballoon ablation. Continuous monitoring during follow-up is performed using an implantable cardiac monitor (ICM) in all patients. The primary endpoint is time to first recurrence of any atrial tachyarrhythmia (AF, atrial flutter, and/or atrial tachycardia) ≥ 120 s between days 91 and 365 post ablation as detected on the (ICM). Procedural safety is assessed by a composite of cardiac tamponade, persistent phrenic nerve palsy >24 h, vascular complications requiring intervention, stroke/transient ischemic attack, atrioesophageal fistula or death occurring during or up to 30 days after the procedure. Key secondary endpoints include (1) procedure and fluoroscopy times, (2) AF burden, (3) proportion of patients with recurrence in the blanking period, (4) proportion of patients undergoing repeat ablation, and (5) quality of life changes at 12 months compared to baseline. CONCLUSION COMPARE CRYO will compare the efficacy and safety of the novel PolarX cryoballoon and the standard-of-practice Arctic Front cryoballoon for first PVI performed in patients with symptomatic paroxysmal AF. TRIAL REGISTRATION (ClinicalTrials.gov ID: NCT04704986).
Collapse
Affiliation(s)
- Jens Maurhofer
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Thomas Kueffer
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Sven Knecht
- Department of Cardiology, University Hospital Basel, University of Basel, Basel, Switzerland
| | - Antonio Madaffari
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Patrick Badertscher
- Department of Cardiology, University Hospital Basel, University of Basel, Basel, Switzerland
| | - Jens Seiler
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Philipp Krisai
- Department of Cardiology, University Hospital Basel, University of Basel, Basel, Switzerland
| | - Corinne Jufer
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Babken Asatryan
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland; Division of Cardiology, Department of Medicine, Johns Hopkins University School of Medicine, Baltimore, MD, United States
| | - Dik Heg
- CTU Bern, University of Bern, Bern, Switzerland
| | - Helge Servatius
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Hildegard Tanner
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Michael Kühne
- Department of Cardiology, University Hospital Basel, University of Basel, Basel, Switzerland
| | - Laurent Roten
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Christian Sticherling
- Department of Cardiology, University Hospital Basel, University of Basel, Basel, Switzerland
| | - Tobias Reichlin
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
| |
Collapse
|
21
|
Almorad A, Del Monte A, Della Rocca DG, Pannone L, Ramak R, Overeinder I, Bala G, Ströker E, Sieira J, Dubois A, Sorgente A, El Haddad M, Iacopino S, Boveda S, de Asmundis C, Chierchia GB. Outcomes of pulmonary vein isolation with radiofrequency balloon vs. cryoballoon ablation: a multi-centric study. Europace 2023; 25:euad252. [PMID: 37671682 PMCID: PMC10481252 DOI: 10.1093/europace/euad252] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2023] [Accepted: 08/14/2023] [Indexed: 09/07/2023] Open
Abstract
AIMS Cryoballoon (CB) ablation is the mainstay of single-shot pulmonary vein isolation (PVI). A radiofrequency balloon (RFB) catheter has recently emerged as an alternative. However, these two technologies have not been compared. This study aims to evaluate the freedom from atrial tachyarrhythmias (ATas) at 1 year: procedural characteristics, efficacy, and safety of the novel RFB compared with CB for PVI in patients with paroxysmal atrial fibrillation (AF). METHODS AND RESULTS This prospective multi-centre study included consecutive patients with symptomatic drug-resistant paroxysmal AF who underwent PVI with RFB or CB between July 2021 and January 2022 from three European centres. A total of 375 consecutive patients were included, 125 in the RFB group and 250 in the CB. Both groups had comparable clinical characteristics. At 12.33 ± 4.91 months, ATas-free rates were 83.20% and 82.00% in the RFB and CB groups, respectively (P > 0.05). Compared with the CB group, the RFB group showed a shorter procedure time [59.91 (45.80-77.12) vs. 77.0 (35.13-122.71) min (P < 0.001)], dwell time [19.59 (14.41-30.24) vs. 27.03 (17.11-57.21) min (P = 0.04)], time to isolation, and thermal energy delivery in all pulmonary veins (P < 0.001). First-pass isolation was comparable. No major complications occurred in either group, with no stroke, atrio-oesophageal fistula, or permanent phrenic nerve injury. Transient phrenic nerve palsy occurred more frequently with CB than RFB (7.20% vs. 3.20%; P = 0.02). Oesophageal temperature rise occurred in 21 (16.8%) patients in the RFB group, and gastroscopy showed erythema in two of them with complete recovery after 30 days. CONCLUSIONS The RFB appears to have a safety and efficacy profile similar to that of the CB for PVI. Shorter procedural times appear to be driven by shorter left atrial dwell and thermal delivery times.
Collapse
Affiliation(s)
- Alexandre Almorad
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel—Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090 Brussels, Belgium
| | - Alvise Del Monte
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel—Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090 Brussels, Belgium
| | - Domenico Giovanni Della Rocca
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel—Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090 Brussels, Belgium
| | - Luigi Pannone
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel—Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090 Brussels, Belgium
| | - Robbert Ramak
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel—Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090 Brussels, Belgium
| | - Ingrid Overeinder
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel—Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090 Brussels, Belgium
| | - Gezim Bala
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel—Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090 Brussels, Belgium
| | - Erwin Ströker
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel—Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090 Brussels, Belgium
| | - Juan Sieira
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel—Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090 Brussels, Belgium
| | - Aurélie Dubois
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel—Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090 Brussels, Belgium
| | - Antonio Sorgente
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel—Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090 Brussels, Belgium
| | | | - Saverio Iacopino
- Arrhythmology Department, Maria Cecilia Hospital SPA, Cotignola, Italy
| | - Serge Boveda
- Département de Rythmologie, Clinique Pasteur, 45 avenue de Lombez, BP 27617, 31076 Toulouse Cedex 3, France
| | - Carlo de Asmundis
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel—Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090 Brussels, Belgium
| | - Gian-Battista Chierchia
- Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel—Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Laarbeeklaan 101, 1090 Brussels, Belgium
| |
Collapse
|
22
|
Heeger CH, Popescu SS, Inderhees T, Nussbickel N, Eitel C, Kirstein B, Phan HL, Hatahet S, Subin B, Traub A, Große N, Kuck KH, Vogler J, Tilz RR. Novel or established cryoballoon ablation system for pulmonary vein isolation: the prospective ICE-AGE-1 study. Europace 2023; 25:euad248. [PMID: 37589146 PMCID: PMC10468200 DOI: 10.1093/europace/euad248] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2023] [Revised: 07/07/2023] [Accepted: 07/25/2023] [Indexed: 08/18/2023] Open
Abstract
AIMS Catheter ablation with a cryoballoon (CB) provides effective and durable pulmonary vein (PV) isolation (PVI) associated with encouraging clinical outcome data. The novel POLARx CB incorporates unique features, which may translate into improved safety, efficacy, and outcomes. The ICE-AGE-1 study aimed to assess the efficacy, safety, and 1-year clinical follow-up of the POLARx CB in comparison to the Arctic Front Advance Pro CB (AF-CB4). METHODS AND RESULTS A total of 103 consecutive patients with paroxysmal or persistent atrial fibrillation (AF) who underwent POLARx-based PVI (POLARx group) were prospectively enrolled and were compared to 102 consecutive patients previously treated with the AF-CB4 (AF-CB4 group). The mean age was 68.7 ± 10.2 (POLARx) and 65.7 ± 12 (AF-CB4, P = 0.0551) years. A total of 412 (POLARx) and 404 (AF-CB4) PVs were identified. All PVs, except for one PV in the POLARx group, were successfully isolated. A significant difference regarding the mean minimal CB temperature reached using the POLARx CB (-56.1 ± 8.3°C) and AF-CB4 (-46.9 ± 10.1°C) was observed (P < 0.0001). Real-time PVI was visualized in 71% of PVs in the POLARx group and 46% of them in the AF-CB4 group (P < 0.001). The mean procedure time was comparable: 54.5 ± 17.1 min for POLARx and 59.4 ± 18.6 min for AF-CB4 (P = 0.0509). No differences were observed in terms of periprocedural complications. There were comparable rates in freedom of AF or atrial tachycardia recurrence after 12 months, beyond a 90-day long blanking period: 78.9% in the POLARx group vs. 77.2% in the AF-CB4 group (P = 0.804). CONCLUSION The novel POLARx CB showed similar safety, efficacy, and 1-year recurrence-free survival rates compared to the AF-CB4. A higher rate of real-time electrical PV recordings and significantly lower balloon temperatures were observed using the POLARx as compared to AF-CB4.
Collapse
Affiliation(s)
- Christian-Hendrik Heeger
- University Heart Center Lübeck, Department of Rhythmology, University Hospital Schleswig-Holstein, Ratzeburger Allee 160, D-23538 Lübeck, Germany
- German Center for Cardiovascular Research (DZHK), Partner Site Hamburg/Kiel/Lübeck, Lübeck, Germany
| | - Sorin Stefan Popescu
- University Heart Center Lübeck, Department of Rhythmology, University Hospital Schleswig-Holstein, Ratzeburger Allee 160, D-23538 Lübeck, Germany
| | - Tim Inderhees
- University Heart Center Lübeck, Department of Rhythmology, University Hospital Schleswig-Holstein, Ratzeburger Allee 160, D-23538 Lübeck, Germany
| | - Noemi Nussbickel
- University Heart Center Lübeck, Department of Rhythmology, University Hospital Schleswig-Holstein, Ratzeburger Allee 160, D-23538 Lübeck, Germany
| | - Charlotte Eitel
- University Heart Center Lübeck, Department of Rhythmology, University Hospital Schleswig-Holstein, Ratzeburger Allee 160, D-23538 Lübeck, Germany
| | - Bettina Kirstein
- University Heart Center Lübeck, Department of Rhythmology, University Hospital Schleswig-Holstein, Ratzeburger Allee 160, D-23538 Lübeck, Germany
| | - Huong-Lan Phan
- University Heart Center Lübeck, Department of Rhythmology, University Hospital Schleswig-Holstein, Ratzeburger Allee 160, D-23538 Lübeck, Germany
| | - Sascha Hatahet
- University Heart Center Lübeck, Department of Rhythmology, University Hospital Schleswig-Holstein, Ratzeburger Allee 160, D-23538 Lübeck, Germany
| | - Behnam Subin
- University Heart Center Lübeck, Department of Rhythmology, University Hospital Schleswig-Holstein, Ratzeburger Allee 160, D-23538 Lübeck, Germany
| | - Anna Traub
- University Heart Center Lübeck, Department of Rhythmology, University Hospital Schleswig-Holstein, Ratzeburger Allee 160, D-23538 Lübeck, Germany
| | - Niels Große
- University Heart Center Lübeck, Department of Rhythmology, University Hospital Schleswig-Holstein, Ratzeburger Allee 160, D-23538 Lübeck, Germany
| | - Karl-Heinz Kuck
- University Heart Center Lübeck, Department of Rhythmology, University Hospital Schleswig-Holstein, Ratzeburger Allee 160, D-23538 Lübeck, Germany
| | - Julia Vogler
- University Heart Center Lübeck, Department of Rhythmology, University Hospital Schleswig-Holstein, Ratzeburger Allee 160, D-23538 Lübeck, Germany
| | - Roland R Tilz
- University Heart Center Lübeck, Department of Rhythmology, University Hospital Schleswig-Holstein, Ratzeburger Allee 160, D-23538 Lübeck, Germany
- German Center for Cardiovascular Research (DZHK), Partner Site Hamburg/Kiel/Lübeck, Lübeck, Germany
| |
Collapse
|
23
|
Tanese N, Almorad A, Pannone L, Defaye P, Jacob S, Kilani MB, Chierchia G, Venier S, Cardin C, Jacon P, Combes S, Deschamps E, Menè R, de Asmundis C, Boveda S. Outcomes after cryoballoon ablation of paroxysmal atrial fibrillation with the PolarX or the Arctic front advance pro: a prospective multicentre experience. Europace 2023; 25:873-879. [PMID: 36695332 PMCID: PMC10062287 DOI: 10.1093/europace/euad005] [Citation(s) in RCA: 24] [Impact Index Per Article: 24.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2022] [Accepted: 12/28/2022] [Indexed: 01/26/2023] Open
Abstract
AIMS The aim of this study was to compare procedural efficacy and safety, including 1-year freedom from AF recurrence, between the novel cryoballoon system PolarX (Boston Scientific) and the Arctic Front Advance Pro (AFA-Pro) (Medtronic), in patients with paroxysmal AF undergoing PVI. METHODS AND RESULTS This multicentre prospective observational study included 267 consecutive patients undergoing a first cryoablation procedure for paroxysmal AF (137 PolarX, 130 AFA-Pro). KM curves with the log-rank test was used to compare the 1-year freedom from AF recurrence between both groups. Multivariate Cox model was performed to evaluate whether the type of procedure (PolarX vs. AFA-Pro) had an impact on the occurrence of AF recurrences after adjustment on potentially confounding factors. The PolarX reaches lower temperatures than the AFA-Pro (LSPV 52 ± 5, vs. 59 ± 6; LIPV 49 ± 6 vs. 56 ± 6; right superior pulmonary vein: 49 ± 6 vs. 57 ± 7; right inferior pulmonary vein: 52 ± 6 vs. 59 ± 6; P < 0.0001). A higher rate of transient phrenic nerve palsy was found in patients treated with the PolarX system (15% vs. 7%, P = 0.05). After a mean follow-up of 15 ± 5 months, 20 patients (15%) had recurrences in AFA-Pro group and 27 patients (19%) in PolarX group (P = 0.35). Based on survival analysis, no significant difference was observed between both groups with a 12-month free of recurrence survival of 91.2% (85.1-95.4%) vs. 83.7% (76.0%-89.1%) (log-rank test P = 0.11). In multivariate Cox model hazard ratio of recurrence for PolarX vs. AFA-Pro was not significant [HR = 1.6 (0.9-2.8), P = 0.12]. CONCLUSION PolarX and AFA-Pro have comparable efficacy and safety profiles for pulmonary veins isolation in paroxysmal atrial fibrillation.
Collapse
Affiliation(s)
- Nikita Tanese
- Heart Rhythm Department, Clinique Pasteur, Toulouse, France.,IRCCS San Raffaele Hospital, Milan, Italy
| | - Alexandre Almorad
- Heart Rhythm Management Center, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, Brussels, Belgium
| | - Luigi Pannone
- Heart Rhythm Management Center, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, Brussels, Belgium
| | - Pascal Defaye
- Arrythmia Departement University Hospital of Grenoble-Alpes and Grenoble Alpes University, Grenboble, France
| | - Sophie Jacob
- Laboratory of epidemiology, Institute of Radiation Protection and Nuclear Safety (IRSN), Fontenay-aux-Roses, France
| | - Mouna Ben Kilani
- Arrythmia Departement University Hospital of Grenoble-Alpes and Grenoble Alpes University, Grenboble, France
| | - Gianbattista Chierchia
- Heart Rhythm Management Center, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, Brussels, Belgium
| | - Sandrine Venier
- Arrythmia Departement University Hospital of Grenoble-Alpes and Grenoble Alpes University, Grenboble, France
| | | | - Peggy Jacon
- Arrythmia Departement University Hospital of Grenoble-Alpes and Grenoble Alpes University, Grenboble, France
| | | | - Elodie Deschamps
- Arrythmia Departement University Hospital of Grenoble-Alpes and Grenoble Alpes University, Grenboble, France
| | - Roberto Menè
- Heart Rhythm Department, Clinique Pasteur, Toulouse, France
| | - Carlo de Asmundis
- Heart Rhythm Management Center, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, Brussels, Belgium
| | - Serge Boveda
- Heart Rhythm Department, Clinique Pasteur, Toulouse, France.,Heart Rhythm Management Center, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, Brussels, Belgium
| |
Collapse
|
24
|
Wang L, Zhang Y, Zhou W, Chen J, Li Y, Tang Q, Chen B, Zhang H, Zellmer L, Chen J, Chen Z, Li W, Liu X, Zhou H. Relationship between left atrial appendage peak flow velocity and nonvalvular atrial fibrillation recurrence after cryoablation. Front Cardiovasc Med 2023; 10:1053102. [PMID: 36937924 PMCID: PMC10017530 DOI: 10.3389/fcvm.2023.1053102] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2022] [Accepted: 02/13/2023] [Indexed: 03/06/2023] Open
Abstract
Background Previous studies revealed the connection between left atrial appendage peak flow velocity (LAA-PEV) and postoperative persistent atrial fibrillation (AF) recurrence. Yet, this association is not necessarily generalizable to persistent AF patients undergoing initial cryoballoon ablation due to current gaps in the literature. Methods We prospectively studied 74 consecutive individuals with persistent atrial fibrillation undergoing a cryoballoon ablation for the first time between January 2018 and January 2020. Before ablation, LAA-PEV was documented by transesophageal echocardiography (TEE). Subsequently, demographic information and other clinical characteristics of these participants were collected. A 96-h continuous cardiac monitor was reviewed regularly for recurrence of atrial fibrillation. Cox proportional hazards regression was used to investigate LAA-PEV as well as other clinical characteristics as a predictor of AF recurrence. Results Our study found that AF recurrences had lower LAA-PEV than those without AF recurrence. A nonlinear relationship between the LAA-PEV and AF recurrence was observed in this study, which had an inflection point of 34.9. Subgroup analysis of female participants showed that LAA-PEV had a positive correlation with AF recurrence [β = 0.8, 95% CI (0.7, 0.9), p < 0.05]. Conclusion A low LAA-PEV is related to recurrence of atrial fibrillation and may predict AF recurrence after initial cryoballoon ablation for persistent atrial fibrillation. This finding may help improve treatment and care strategies for patients with persistent atrial fibrillation.
Collapse
Affiliation(s)
- Long Wang
- Department of Cardiology, The Affiliated Hospital of Guizhou Medical University, Guiyang, Guizhou, China
| | - Yan Zhang
- Department of Cardiology, The Affiliated Hospital of Guizhou Medical University, Guiyang, Guizhou, China
| | - Wei Zhou
- Department of Cardiology, The Affiliated Hospital of Guizhou Medical University, Guiyang, Guizhou, China
| | - Jingjing Chen
- Department of Cardiology, The Affiliated Hospital of Guizhou Medical University, Guiyang, Guizhou, China
| | - Yongkang Li
- Department of Cardiology, The Affiliated Hospital of Guizhou Medical University, Guiyang, Guizhou, China
| | - Qian Tang
- Department of Cardiology, The Affiliated Hospital of Guizhou Medical University, Guiyang, Guizhou, China
| | - Bingxiu Chen
- Department of Cardiology, The Affiliated Hospital of Guizhou Medical University, Guiyang, Guizhou, China
| | - Huiling Zhang
- Department of Cardiology, The Affiliated Hospital of Guizhou Medical University, Guiyang, Guizhou, China
| | - Lucas Zellmer
- Department of Internal Medicine, Hennepin County Medical Center, Minneapolis, MN, United States
| | - Jin Chen
- Department of Cardiology, The Affiliated Hospital of Guizhou Medical University, Guiyang, Guizhou, China
| | - Zhangrong Chen
- Department of Cardiology, The Affiliated Hospital of Guizhou Medical University, Guiyang, Guizhou, China
| | - Wei Li
- Department of Cardiology, The Affiliated Hospital of Guizhou Medical University, Guiyang, Guizhou, China
| | - Xingde Liu
- Department of Internal Medicine, School of Clinical Medicine, Guizhou Medical University, Guiyang, Guizhou, China
- *Correspondence: Haiyan Zhou, ; Xingde Liu,
| | - Haiyan Zhou
- Department of Cardiology, The Affiliated Hospital of Guizhou Medical University, Guiyang, Guizhou, China
- *Correspondence: Haiyan Zhou, ; Xingde Liu,
| |
Collapse
|